Higher Burnup Workshop V September 3, 2024

Opening Remarks Andrea Kock Deputy Office Director NRR

Agenda Time Topic Speaker 9:00 am Welcome NRC 9:05 am Opening Remarks NRC 9:10 am Accident Tolerant Fuel and Increased Enrichment Rulemaking Update NRC 9:35 am Industry Motivation for Use of Higher Burnup Industry 9:55 am 10 CFR 50.46a/c Industry 10:25 am Open Discussion All 10:35 am Break 10:45 am Phenomena Identification and Ranking Tables for High Burnup Fuel Fragmentation, Relocation, Dispersal, and Its Consequences for Design-Basis Accidents NRC 11:00 am Proposed FFRD dose consequence guidance in DG-1425 (Draft Rev 2 of RG 1.183)

NRC 11:15 am Environmental Evaluation of ATF with Increased Enrichment and Higher Burnup Levels NRC 11:30 am Spent Fuel Pool Regulatory Perspective NRC 11:45 am High Burnup Summary DOE 12:05 pm Open Discussion All 12:15 pm Public Comment Period Public 12:25 pm Closing Remarks NRC 12:30 pm Adjourn NRC Topic times are estimated based on the participation level and presentation length.

Meeting visuals and audio are through MS Teams.

Participants are in listen-only mode until the discussion and public feedback period. During which, we will first allow in-person attendees to participate, then allow remote attendees to un-mute.

Remote attendees should utilize the hand raised feature in MS Teams, if possible.

This is an Observation Meeting. Public participation and comments are sought during specific points during the meeting.

NRC will consider the input received but will not prepare written responses.

No regulatory decisions will be made during this meeting.

This meeting is being recorded.

Meeting Logistics

Meeting Purpose

  • Exchange information between NRC and industry on higher burnup, increased enrichment, and Accident Tolerant Fuel (ATF) activities.
  • Provide an opportunity for members of the public to ask questions of the NRC staff.

Accident Tolerant Fuel and Increased Enrichment Update James Delosreyes, NRR/DORL Philip Benavides, NMSS/REFS

Updates to the Roadmap to Readiness

  • Available at:

https://www.nrc.gov/reactors/power/atf.html

https://www.nrc.gov/reactors/power/atf/burnup.html https://www.nrc.gov/reactors/power/atf/burnup.html https://www.nrc.gov/reactors/power/atf/burnup.html https://www.nrc.gov/reactors/power/atf/burnup.html https://www.nrc.gov/reactors/power/atf/burnup.html https://www.nrc.gov/reactors/power/atf/burnup.html https://www.nrc.gov/reactors/power/atf/burnup.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/enrichment.html https://www.nrc.gov/reactors/power/atf/enrichment.html https://www.nrc.gov/reactors/power/atf/enrichment.html https://www.nrc.gov/reactors/power/atf/enrichment.html https://www.nrc.gov/reactors/power/atf/enrichment.html https://www.nrc.gov/reactors/power/atf/enrichment.html https://www.nrc.gov/reactors/power/atf/enrichment.html https://www.nrc.gov/reactors/power/atf/enrichment.html https://www.nrc.gov/reactors/power/atf/enrichment.html https://www.nrc.gov/reactors/power/atf/enrichment.html https://www.nrc.gov/reactors/power/atf/enrichment.html https://www.nrc.gov/reactors/power/atf/enrichment.html https://www.nrc.gov/reactors/power/atf/enrichment.html https://www.nrc.gov/reactors/power/atf/project-plan.html https://www.nrc.gov/reactors/power/atf/project-plan.html https://www.nrc.gov/reactors/power/atf/project-plan.html https://www.nrc.gov/reactors/power/atf/project-plan.html https://www.nrc.gov/reactors/power/atf/project-plan.html https://www.nrc.gov/reactors/power/atf/project-plan.html https://www.nrc.gov/reactors/power/atf/project-plan.html https://www.nrc.gov/reactors/power/atf/project-plan.html https://www.nrc.gov/reactors/power/atf/project-plan.html https://www.nrc.gov/reactors/power/atf/origins.html#neima https://www.nrc.gov/reactors/power/atf/origins.html#neima https://www.nrc.gov/reactors/power/atf/origins.html#neima https://www.nrc.gov/reactors/power/atf/origins.html#neima https://www.nrc.gov/reactors/power/atf/origins.html#neima https://www.nrc.gov/reactors/power/atf/origins.html#neima https://www.nrc.gov/reactors/power/atf/origins.html#neima https://www.nrc.gov/docs/ML2131/ML21313A145.pdf https://www.nrc.gov/docs/ML2131/ML21313A145.pdf https://www.nrc.gov/docs/ML2131/ML21313A145.pdf https://www.nrc.gov/docs/ML2131/ML21313A145.pdf https://www.nrc.gov/docs/ML2131/ML21313A145.pdf https://www.nrc.gov/docs/ML2131/ML21313A145.pdf https://www.nrc.gov/docs/ML2131/ML21313A145.pdf https://www.nrc.gov/docs/ML2111/ML21113A277.pdf https://www.nrc.gov/docs/ML2111/ML21113A277.pdf https://www.nrc.gov/docs/ML2111/ML21113A277.pdf https://www.nrc.gov/docs/ML2111/ML21113A277.pdf https://www.nrc.gov/docs/ML2111/ML21113A277.pdf https://www.nrc.gov/docs/ML2111/ML21113A277.pdf https://www.nrc.gov/reactors/power/atf/industry-interact.html https://www.nrc.gov/reactors/power/atf/industry-interact.html https://www.nrc.gov/reactors/power/atf/industry-interact.html https://www.nrc.gov/reactors/power/atf/industry-interact.html https://www.nrc.gov/reactors/power/atf/industry-interact.html https://www.nrc.gov/reactors/power/atf/public-interact.html https://www.nrc.gov/reactors/power/atf/public-interact.html https://www.nrc.gov/reactors/power/atf/public-interact.html https://www.nrc.gov/reactors/power/atf/public-interact.html https://www.nrc.gov/reactors/power/atf/public-interact.html https://www.nrc.gov/reactors/power/atf/public-interact.html https://www.nrc.gov/reactors/power/atf/public-interact.html https://www.nrc.gov/reactors/power/atf/public-interact.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/review/independent-con"rm-calc.html https://www.nrc.gov/reactors/power/atf/review/independent-con"rm-calc.html https://www.nrc.gov/reactors/power/atf/review/independent-con"rm-calc.html https://www.nrc.gov/reactors/power/atf/review/independent-con"rm-calc.html https://www.nrc.gov/reactors/power/atf/review/independent-con"rm-calc.html https://www.nrc.gov/reactors/power/atf/review/independent-con"rm-calc.html https://www.nrc.gov/reactors/power/atf/review/independent-con"rm-calc.html https://www.nrc.gov/reactors/power/atf/review/independent-con"rm-calc.html https://www.nrc.gov/reactors/power/atf/public-interact.html https://www.nrc.gov/reactors/power/atf/public-interact.html https://www.nrc.gov/reactors/power/atf/public-interact.html https://www.nrc.gov/reactors/power/atf/public-interact.html https://www.nrc.gov/reactors/power/atf/public-interact.html https://www.nrc.gov/reactors/power/atf/public-interact.html https://www.nrc.gov/reactors/power/atf/public-interact.html https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23240A756 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://www.nrc.gov/reactors/power/atf/doped-pellets.html https://www.nrc.gov/reactors/power/atf/doped-pellets.html https://www.nrc.gov/reactors/power/atf/doped-pellets.html https://www.nrc.gov/reactors/power/atf/doped-pellets.html https://www.nrc.gov/reactors/power/atf/doped-pellets.html https://www.nrc.gov/reactors/power/atf/doped-pellets.html https://www.nrc.gov/reactors/power/atf/doped-pellets.html https://www.nrc.gov/reactors/power/atf/doped-pellets.html https://www.nrc.gov/reactors/power/atf/doped-pellets.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/docs/ML2200/ML22003A168.pdf https://www.nrc.gov/docs/ML2200/ML22003A168.pdf https://www.nrc.gov/docs/ML2200/ML22003A168.pdf https://www.nrc.gov/docs/ML2200/ML22003A168.pdf https://www.nrc.gov/docs/ML2200/ML22003A168.pdf https://www.nrc.gov/docs/ML2200/ML22003A168.pdf https://www.nrc.gov/docs/ML2200/ML22003A168.pdf https://www.regulations.gov/docket/NRC-2020-0034 https://www.regulations.gov/docket/NRC-2020-0034 https://www.regulations.gov/docket/NRC-2020-0034 https://www.regulations.gov/docket/NRC-2020-0034 https://www.regulations.gov/docket/NRC-2020-0034 https://www.regulations.gov/docket/NRC-2020-0034 https://www.regulations.gov/docket/NRC-2020-0034 https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/docs/ML2201/ML22014A112.pdf https://www.nrc.gov/docs/ML2201/ML22014A112.pdf https://www.nrc.gov/docs/ML2201/ML22014A112.pdf https://www.nrc.gov/docs/ML2201/ML22014A112.pdf https://www.nrc.gov/docs/ML2201/ML22014A112.pdf https://www.nrc.gov/reactors/power/atf/chrom-clad.html https://www.nrc.gov/reactors/power/atf/chrom-clad.html https://www.nrc.gov/reactors/power/atf/chrom-clad.html https://www.nrc.gov/reactors/power/atf/chrom-clad.html https://www.nrc.gov/reactors/power/atf/chrom-clad.html https://www.nrc.gov/reactors/power/atf/chrom-clad.html https://www.nrc.gov/reactors/power/atf/chrom-clad.html https://www.nrc.gov/reactors/power/atf/chrom-clad.html https://www.nrc.gov/reactors/power/atf/chrom-clad.html https://www.nrc.gov/reactors/power/atf/chrom-clad.html https://www.nrc.gov/reactors/power/atf/chrom-clad.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/lead-test.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/docs/ML1934/ML19343A121.pdf https://www.nrc.gov/docs/ML1934/ML19343A121.pdf https://www.nrc.gov/docs/ML1934/ML19343A121.pdf https://www.nrc.gov/docs/ML1934/ML19343A121.pdf https://www.nrc.gov/docs/ML1934/ML19343A121.pdf https://www.nrc.gov/docs/ML1934/ML19343A121.pdf https://www.nrc.gov/docs/ML1934/ML19343A121.pdf https://www.nrc.gov/docs/ML1934/ML19343A121.pdf https://www.nrc.gov/docs/ML1934/ML19343A121.pdf https://www.nrc.gov/docs/ML1934/ML19343A121.pdf https://www.nrc.gov/docs/ML1934/ML19343A121.pdf https://www.nrc.gov/docs/ML1934/ML19343A121.pdf https://www.nrc.gov/docs/ML1934/ML19343A121.pdf https://www.nrc.gov/docs/ML1934/ML19343A121.pdf https://www.nrc.gov/docs/ML1917/ML19172A154.pdf https://www.nrc.gov/docs/ML1917/ML19172A154.pdf https://www.nrc.gov/docs/ML1917/ML19172A154.pdf https://www.nrc.gov/docs/ML1917/ML19172A154.pdf https://www.nrc.gov/docs/ML1917/ML19172A154.pdf https://www.nrc.gov/docs/ML1917/ML19172A154.pdf https://www.nrc.gov/docs/ML1917/ML19172A154.pdf https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/

https://www.nrc.gov/

https://www.nrc.gov/

https://www.nrc.gov/

https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://www.nrc.gov/reactors/power/atf/licensing-actions.html https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML24155A058 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML24155A058 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML24155A058 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML24155A058 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML24155A058 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML24155A058 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML24155A058 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML24155A058 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML24155A058 https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://www.nrc.gov/reactors/power/atf/doe-interact.html#coordin https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23082A305 https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://www.nrc.gov/reactors/power/atf.html https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23135A021 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23135A021 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23135A021 https://adamswebsearch2.nrc.gov/webSearch2/main.jsp?AccessionNumber=ML23135A021 https://www.nrc.gov/reactors/power/atf/interactions/industry-interact.html https://www.nrc.gov/reactors/power/atf/interactions/industry-interact.html https://www.nrc.gov/reactors/power/atf/interactions/industry-interact.html https://www.nrc.gov/reactors/power/atf/interactions/industry-interact.html https://www.nrc.gov/reactors/power/atf/interactions/industry-interact.html https://www.nrc.gov/reactors/power/atf/interactions/industry-interact.html https://www.nrc.gov/reactors/power/atf/interactions/industry-interact.html https://www.nrc.gov/reactors/power/atf/interactions/industry-interact.html https://www.nrc.gov/reactors/power/atf/interactions/industry-interact.html https://www.nrc.gov/reactors/power/atf/interactions/industry-interact.html https://www.nrc.gov/reactors/power/atf/interactions/industry-interact.html https://www.nrc.gov/reactors/power/atf/interactions/industry-interact.html Accident Tolerant Fuel (ATF), Increased Enrichment, and Higher Burnup Roadmap to Readiness ATF PROJECT PLAN ISSUED OCTOBER 2019 NUCLEAR ENERGY INNOVATION AND MODERNIZATION ACT ISSUED JANUARY 2019 2019 COATED CLADDING DOPED PELLETS STAKEHOLDER ENGAGEMENT INCREASED ENRICHMENT (IE)

HIGHER BURNUP (HBU)

RESEARCH &

DEVELOPMENT VENDOR TOPICAL REPORTS LEAD TEST ASSEMBLIES VENDOR TOPICAL REPORTS SEVERE ACCIDENT PIRT ISSUED APRIL 2021 FUEL FRAGMENTATION, RELOCATION, AND DISPERSAL (FFRD) RESEARCH INFORMATION LETTER (RIL) 202113 ISSUED DECEMBER 2021 PUBLIC MEETINGS:

COMMISSION MEETINGS, RIC, HBU WORKSHOPS INDUSTRY WORKING GROUPS AND WORKSHOPS ANTICIPATED SCHEDULE LETTER ISSUED JANUARY 2022 REGULATORY FRAMEWORK APPLICABILITY ASSESSMENT (RFAA)

ISSUED MAY 2022 REGULATORY ISSUE

SUMMARY

(RIS)

ISSUED NOVEMBER 2019 AND JUNE 2023 Refer to the New Fuels Infographic for information regarding fuel facilities, transportation, and spent fuel storage.

CODE DEVELOPMENT

~2027 PWRs and

~2030 BWRs BATCH LOAD NEARTERM ATF CONCEPTS DESTINATION IE RULEMAKING SRMSECY21109 EXPECTED FALL 2026 NUREG ON ENVIRONMENTAL EVALUATION OF ATF WITH IE AND HBU EXPECTED FALL 2024 LEAD TEST ASSEMBLIES FFRD PIRT ISSUED MAY 2024 TRANSPORTATION PACKAGES RG 1.183 REV. 1 SOURCE TERM ISSUED OCTOBER 2023

& RG 1.183 REV. 2 EXPECTED 2025 REVISION TRANSPORTATION PACKAGES PLANT LICENSING AMENDMENT INTERIM STAFF GUIDANCE ISSUED JANUARY 2020 CHROMIUM COATED CLADDING PHENOMENA IDENTIFICATION AND RANKING TABLE (PIRT)

ISSUED JUNE 2019 VENDOR TOPICAL REPORTS LEAD TEST ASSEMBLIES TRANSPORTATION PACKAGES RESEARCH &

DEVELOPMENT RG 1.183 REV.1 SOURCE TERM ISSUED OCTOBER 2023

& RG 1.183 REV. 2 EXPECTED 2025 REVISION TRANSPORTATION PACKAGES RESEARCH &

DEVELOPMENT RG 1.183 REV. 1 SOURCE TERM ISSUED OCTOBER 2023

& RG 1.183 REV. 2 EXPECTED 2025 REVISION IE RULEMAKING SRM-SECY-21-109

ADVANCE Act

  • Signed into law on 7/19/24 with wide bipartisan support.
  • Accelerating deployment of versatile, advanced nuclear for clean energy.
  • Builds upon initiatives begun with NEICA in 2017 and continued with NEIMA in 2019.

ADVANCE Act Advanced Nuclear Reactors Nuclear Fusion Reactors Advanced Nuclear Fission Reactors Research and Test Reactors Advanced Nuclear Reactor Technology Advanced Nuclear Fuel Advanced Nuclear Reactor Fuel Accident Tolerant Fuel

ADVANCE Act Accident Tolerant Fuel Makes an existing commercial nuclear reactor more resistant to a nuclear incident and Lowers the cost of electricity over the licensed lifetime of an existing commercial nuclear reactor.

Advanced Nuclear Fuel Ceramic cladding materials; Fuels containing silicon carbide; High-assay, low-enriched uranium fuels; Molten-salt based liquid fuels; Fuels derived from spent nuclear fuel or depleted uranium and Other related fuel concepts, as determined by the Commission

Status of Rulemaking Activity

  • The NRC staff is preparing the IE proposed rule package regarding supporting industry interest in the use of fuel enriched to greater than 5.0 weight percent U-235.
  • The public comment period for the regulatory basis closed on 1/22/24.
  • The Commission approved a three-month extension to the IE rulemaking effort on 6/17/24 to support further work regarding Fuel Fragmentation, Release, and Dispersal (FFRD).

2023 2024 2025 2026 SRM 3/16/22 Regulatory Basis 3/16/22-9/15/23 Public Comment Period 9/16/23-1/22/24 Proposed Rule Package 1/22/24-3/14/25 Commission Review 3/14/25-6/16/25 Revise Proposed Rule 6/17/25-7/17/25 Public Comment Period 7/17/25-9/30/25 Final Rule to Commission 9/30/26 Note: Dates listed are estimates only, and thus are subject to change.

Extension Approved 6/17/24 Status of Rulemaking Activity 2022

Stay Updated on IE Rulemaking Go to https://www.regulations.gov/ and search for docket ID NRC-2020-0034

FFRD and 50.46c Next Steps 2024 NRC High Burnup Workshop Joseph Messina Nuclear Methods and Fuel Analysis September 3, 2024 15

Purpose

  • The purpose of this presentation is to provide a high-level update on:

- The activities related to FFRD in the Increased Enrichment rulemaking and

- The NRC staffs plan to address the Commissions SRM on the 50.46c draft final rule (SRM-SECY-16-0033)

  • The information presented in these slides is preliminary and has not been approved by the Commission.

- The Commission will vote on the Increased Enrichment draft proposed rule.

  • The NRC staff is not soliciting stakeholder comments in this meeting

- There will be opportunity for public comment once the Commission votes on the draft proposed rule 16

IE Rulemaking Regulatory Basis FFRD Alternatives The IE Rulemaking Regulatory Basis (ML23032A504) considered 5 licensing pathways for addressing fuel dispersal:

  • Alternative 1: No action.
  • Alternative 2: 50.46a-style modification of ECCS requirements.
  • Alternative 3: Perform a safety demonstration for post-FFRD consequences.
  • Alternative 4: Provide a generic bounding assessment of dose and use risk insights for post-FFRD consequences.
  • Alternative 5: Use probabilistic fracture mechanics to show that leaks in large pipes will be identified before failure, precluding the need to analyze LBLOCAs.

17

Fuel Dispersal Path Forward

  • The NRC staff plans to risk-inform LOCAs by modernizing 50.46a (based on Alternative 2) in the IE draft proposed rule to facilitate addressing fuel dispersal

- Support for Alternative 2 expressed in many public comments

- Smallest impact on the IE Rulemaking schedule of the alternatives that received support Leveraging the technical basis and work performed in the original 50.46a

- High level of technical maturity

  • 10 CFR 50.46a was a draft final rule in 2010 that proposed to establish a transition break size (TBS), above which LOCAs would be recategorized as beyond-design-basis

- Voluntary alternative to 50.46

- Original philosophy being maintained with some changes

Addressing Fuel Dispersal

  • The 50.46a approach is expected to facilitate safety demonstrations of fuel dispersal because true best-estimate modeling and realistic assumptions are expected to significantly reduce or eliminate the potential for fuel dispersal
  • While this approach does not explicitly address non-mechanistic approaches to evaluating FFRD, as described in other alternatives in the IE Regulatory Basis, other licensing pathways exist

- E.g., the topical report review process

- The performance-based criteria are expected to provide relief to the prescriptive philosophy of the existing regulatory framework (including a less stringent definition of core coolability) 19

Highlighted Work to Support the IE Proposed Rule Confirmation of the transition break size (TBS)

NRC internal and external expert elicitation xLPR runs of the NUREG-1829 bases cases Evaluation of operating experience Confirmation of NUREG-1903 technical basis Update of the following draft regulatory guides:

DG-1261, Measuring Breakaway Oxidation DG-1262, Determining Post Quench Ductility DG-1263, Establishing Analytical Limits for Zirconium-Alloy Cladding Material Development of the following draft regulatory guides:

DG-1426, An Approach for a Risk-Informed Evaluation Process for Supporting Alternative Acceptance Criteria for Emergency Core Cooling Systems for Light-Water Reactors DG-1428, Plant Specific Applicability of the Transition Break Size DG-1434, Addressing the Consequences of Fuel Dispersal in Light-Water Reactor Loss-of-Coolant Accidents 20

General Considerations Consideration is being given to comments received on the Regulatory Basis regarding 50.46a and 50.46c as well as some comments on the original 50.46a rulemaking. For example, some things that are being considered:

  • True best estimate calculations (nominal, without biases or uncertainties) of ECCS performance for LOCAs greater than the TBS
  • Moving specific ECCS criteria for Zirconium-UO2 fuel systems to guidance (DG-1263)
  • Relaxation of breakaway oxidation reporting requirement in DG-1261
  • Allowing low power and shutdown to be addressed with non-PRA methods
  • Difficulty in demonstrating TBS applicability (i.e., DG-1428)

- Considering periodic weld inspection requirement, which may reduce burden of DG-1428

- Guidance on seismic considerations in DG-1428

- Other implementation requirements may be needed 21

50.46C UPDATE 22

SRM-SECY-16-0033 (50.46c)

The Commission returned the 50.46c draft final rule package (SECY-16-0033) to the staff without Commission action and directed the staff to do the following:

1.

The staff should apply an appropriate risk-informed regulatory approach to address the research findings on cladding embrittlement effects under LOCA conditions described in SECY-16-0033.

2.

The staff should evaluate Item 1 with other associated technical issues being addressed, such as fuel fragmentation relocation and dispersal, and risk-informed treatment of LOCAs, including the draft final 50.46a that had been provided in SECY-10-0161.

3.

The staff should evaluate whether specific emergency core cooling system criteria such as cladding temperature should be codified or instead addressed in regulatory guidance.

4.

Within six months of the date of this SRM, the staff should provide, through a Commissioner Assistants Note, an action plan for the above items.

(SRM-SECY-16-0033, ML24102A281, April 11, 2024) 23

50.46c Path Forward The staff plans to include aspects of 50.46c in voluntary provisions of the Increased Enrichment (IE) proposed rule and assess the need for further action on the 50.46c rulemaking after the Commission votes on the IE final rule package (estimated date to Commission is Sept 2026).

The staff is planning to risk inform LOCAs, as suggested in SRM-SECY-16-0033, with 50.46a in order to facilitate safety demonstrations of fuel dispersal in the IE proposed rule.

The staff would use the public comments received on the 50.46c aspects of the IE rulemaking to inform any potential future action on the 50.46c rulemaking.

The staff will continue to perform the annual ECCS Safety Assessments and evaluate the impacts of the cladding embrittlement research findings within the framework of existing regulatory requirements when reviewing industry submittals that could result in cladding embrittlement impacts (e.g., power uprates or burnup increases).

24

QUESTIONS?

25

© 2024 Electric Power Research Institute, Inc. All rights reserved.

w w w. e p r i. c o m Fred Smith, Sr. Technical Executive Fuel Reliability Program, EPRI NRC HBU Workshop September 3rd, 2024 Industry Motivation for Use of Industry Motivation for Use of Higher Burnup

© 2024 Electric Power Research Institute, Inc. All rights reserved.

27 Electricity Demand Growth Drivers Inflation Reduction Act tax credits Production Tax Credits for existing reactors (45U, 45Y)

Investment Tax Credit new facilities or capacity (48E)

Assessing Future Load: Modeling the factors driving future electricity demand. EPRI, Palo Alto, CA: 2024. 3002029620.

IEA projects, Global electricity demand to rise at a faster rate over the next three years by an average of 3.4%

annually through 2026. In the IEAs Net Zero 2050 scenario, electricitys share of the final energy mix nears 30% in 2030 (comparted to 20% in 2023).

https://www.iea.org/reports/electricity-2024/executive-summary Assessing Future Load: Modeling the factors driving future electricity demand. EPRI, Palo Alto, CA: 2024. 3002029620.

https://www.ercot.com/gridinfo/load/forecast/

© 2024 Electric Power Research Institute, Inc. All rights reserved.

28 NEI Survey: Power Uprate and Cycle Length Extension Key takeaways:

- >55% of sites have a level of interest/planning for one or more power uprates with a combined capacity increase of 2.5 GWe

- Nearly 33% of planned uprates are EPUs,

~50% are SPUs, and remainder are MURs

- ~75% of PWRs interested in extended cycles Interests in uprates are high due in part to the IRA tax credits and projected electricity demand signals, but is ultimately about the underlying plant specific business cases

© 2024 Electric Power Research Institute, Inc. All rights reserved.

29 Extended Fuel Cycle Lengths Most PWRs require higher burnup and increased enrichment for 24-month fuel cycles Plants with 24-month cycles Plants with projected 24-month cycles Evaluation of current US PWR fleet using current burnup and enrichment limits Batch fraction and power density criteria Only low power density PWRs can transition to 24-month fuel cycles at current enrichment/burnup levels All BWRs can operate 24-month fuel cycles All but one does so in the US Cycle lengths greater than 24-month fuel cycle lengths are not likely to be practical Worldwide utilities are considering longer fuel cycles (annual to 15/18-months or 18-to 24-months)

Other benefits of longer cycles:

Better coordination of outage work force across a fleet More time to plan outages Improved work/life balance

© 2024 Electric Power Research Institute, Inc. All rights reserved.

30 Uncertainties in Cycle Length Extension Decision Analysis Factors impacting decisions to transition to longer cycles

- Impact of Electricity Demand on Market Price

- Geo-political impacts on Uranium Market Price

- Inflation and aging workforce impacts on Costs

- Seasonal variations on Electricity Demand due to weather

- Treatment of back-end disposal costs Factors and associated risks vary from licensee to licensee

- They may arrive at different decision on longer cycles

© 2024 Electric Power Research Institute, Inc. All rights reserved.

31 Decision Analysis for Extended Cycle Lengths Typical PWR Results for 4 x 18 Month Fuel Cycles compared to 3 x 24 Month Fuel Cycles*

With HBU/HE Without HBU/HE Fuel Cost Increase (at higher rate than the cycle energy increases)

$4.6M

$109M Outage Cost (saves one outage in 6 years)

$-45.0M

$-45.0M Addition Generation (1.5% CF increase)

$-28.3M

$-28.3M Capital

$ 1M

$ 1M Net

$-22.8M

$81M Net benefit is only for higher burnup and high enrichment

  • Based on methods employed in The Economic Benefits and Challenges with Utilizing Increased Enrichment and Fuel Burnup for LightWater Reactors, NEI 2019

© 2024 Electric Power Research Institute, Inc. All rights reserved.

32 Power Uprates NEI survey of US reactors projects 2.5 GWe of nuclear capacity additions*

Technical basis to enable uprates are needed Existing fuel design limits can limit the uprate and make it more expensive. To address this impact:

- Increased Enrichment and Higher Burnup Fuel

- Advanced Cladding and other Fuel Technologies

- Time-at-temperature T/S based operating limits

- Updated LOCA methods

  • More information available at: Facilitating Power Uprates at Nuclear Power Plants: Feasibility Study Guideline. EPRI, Palo Alto, CA: 2023. 3002026402
  • NEI State of the Nuclear Energy Industry, 2024

© 2024 Electric Power Research Institute, Inc. All rights reserved.

33 Time-at-Temperature (TaT)

Current regulation established to avoid

- Boiling transition

- Cladding over heating

- Fuel failures Current regulation does not account for large margin between onset of boiling transition and fuel failure conditions in moderate frequency transients Coated cladding technologies (ATF) may provide additional margin CRAFT Supported PERT 2024-2025 Several Potential Benefits of Revised TaT Criteria

- Enable higher power uprates

- Improved operating limits

- Up to 5% improvements in fuel margins

- Prompt return to operation after unexpected transient occurrences

- Reduced dose consequences during select transients EPRI and DOE labs are collaborating on material testing through CRAFT

© 2024 Electric Power Research Institute, Inc. All rights reserved.

34 Other Related Areas of Interest Resolution of FFRD issue Updated LOCA analysis framework Resolution of Accident Source Term Challenges RG 1.183

© 2024 Electric Power Research Institute, Inc. All rights reserved.

35

© 2024 Electric Power Research Institute, Inc. All rights reserved.

35

© 2024 Electric Power Research Institute, Inc. All rights reserved.

w w w. e p r i. c o m TOGETHERSHAPING THE FUTURE OF ENERGY TOGETHERSHAPING THE FUTURE OF ENERGY

©2024 Nuclear Energy Institute 1 Aladar Csontos, Director Fuels (NEI)

Tom Kindred, Consulting Engineer (SNC)

Paul Clifford, Consultant (Framatome)

Industry Perspectives on a Modernized and Combined Risk-Informed LOCA Rule (10 CFR 50.46a/c)

September 3rd, 2024

ADVANCE Act - Opportunities to Enable Change Key Provisions:

American Nuclear Leadership Developing and Deploying New Nuclear Technologies Preserving Existing Nuclear Energy Generation Nuclear Fuel Cycle, Supply Chain, Infrastructure, and Workforce Improving Commission Efficiency Aligned with intent of recent NRC Activities:

Reactor Accident Analysis Modernization (RAAM) Project SECY-21-0109: Increased Enrichment Rulemaking SRM-SECY-16-0033: Commission SRM (RI and combine 50.46a/c)

Accident Tolerant Fuel and Power Uprate Project Plan/Charter

©2024 Nuclear Energy Institute 3 Overview Draft 50.46a (SECY-10-0161) Rule - Background Commission PRA Policy Statement 10 CFR 50.46 a Defense in Depth Rule?

LOCAs not Significant Contributors to Plant Risk Considerations/Clarifications for Modernized 50.46a Rule Technology-Neutral 50.46c Requirements

©2024 Nuclear Energy Institute 4 Draft 50.46a Rule (Background)

ML102210460 - Draft Final 50.46a Rule (2010)

Contained a thorough and well thought out rule for risk-informing LOCA analysis under 10 CFR 50.46 However, the rule was not fully risk-informed Required a significant amount of PRA overhead Plant specific analysis for breaks considered beyond design basis Plant specific seismic evaluations Commission approval of change control program for changes under 50.46a In 2010, the general consensus was the large overhead required by utilities to implement a 50.46a rule was not worth the modest potential benefits due to the large overhead required.

©2024 Nuclear Energy Institute 5 Commission PRA Policy Statement PRA and associated analyses should be used in regulatory matters, where practical within the bounds of the state-of-the-art, to reduce unnecessary conservatism associated with current regulatory requirements, regulatory guides, license commitments, and staff practices. Where appropriate, PRA should be used to support the proposal for additional regulatory requirements in accordance with 10 CFR 50.109 (Backfit Rule). The existing rules and regulations shall be complied with unless these rules and regulations are revised.

State of the Art (SOA) for PRAs and probabilistic fracture mechanics (PFM) have changed since 2010 and 1988 (last revision to 10 CFR 50.46)

RG-1.245 Endorses use of xLPR (industry tool for realistically estimating PFM)

Confirms probability of rupture is realistically predicted by NUREG-1829 PRA quality and pedigree has improved with utility implementation of RI programs (Risk Informed Completion Times, 50.69 categorizations, Surveillance Frequency Control Programs, Reactor Oversight Process)

RG-1.200 (Quality of PRAs)

Endorses NEI 17-07 for quality standards for PRA Peer Reviews A modernized 50.46a rule is an ideal candidate for RI policy as significant changes in PRA quality and SOA of PFM can be confirmed

©2024 Nuclear Energy Institute 6 10 CFR 50.46 a Defense in Depth Rule?

10 CFR 100 and 50.67 for offsite/onsite dose consequences

The dose consequence analyses take no credit for ECCS performance and assumes a full core melt

SAND2023-01313

Plants demonstrate 50.67 acceptance criteria from analyses that do not credit ECCS/50.46 analyses Additional DiD provided by

10 CFR 50.155 (SAMGs, SAWA, SAWM, FLEX)

Credited in NUREG-1935

10 CFR 50.47 Emergency Planning

©2024 Nuclear Energy Institute 7 LOCAs not Significant Contributors to Overall Plant Risk

Review of Industry Baseline Risk Index for Initiating Events (BRIIE) - NUREG/CR-6932 for Initiating Events leading to core damage (1988-2005):

VSLOCAs have CDFs on the order of 1E-10 (BWRs) and 1E-09 (PWRs) yr-1

Small sample of plants confirm.

MLOCAs slightly higher but on the order of E-7 to E-8 (PWR, BWRs) yr-1 for CDF

LERF values ~ 2-3 orders of magnitude smaller than CDF E-9 to E-11 yr-1 for LERF

Compared to mean CDFs of 1E-05 and 1E-06 yr-1

OE Extended to 2020 in INL/EXT-21-63577

Plant risk and safety performance have continued to improve (utilities focusing on maintenance and improvements that positively impact risk, safety, and operability)

©2024 Nuclear Energy Institute 8 Considerations/Clarifications for Modernized 50.46a Rule Consideration/Clarification Justification LOCAs > transition break size (TBS) would be beyond design basis. Additional demonstration analyses under 10 CFR 50.46 may not be needed due to extremely low probability of occurrence and associated risk?

Consistent with intent of 50.46a (SECY-10-0161)

Considerations based on discussions on Reactor Accident Analysis Modernization Report: Item 2.4 (ML24220A292)

Do improvements in PRA quality (RG-1.200) and use of PRA acceptance criteria negate the need for a 50.46 demonstration analysis above the TBS?

LOCAs < TBS (design basis) could take credit for RI single failure, RI for crediting non-safety SSCs, and use alternate criteria to demonstrate high probability?

LOCAs are not significant contributors to plant risk and ECCS performance is not credited to satisfy dose acceptance criteria?

Based on industry interpretation of RAAM Items 2,2, 2.3, 2.6 Selection of TBS could be based on risk criteria (CDF, LERF)?

Draft 50.46a rule used initiation event frequency which is not a true risk metric (omits consequences)?

Separate approval of changes under 50.46a may not be required?

Utilities that have received approval for other RI programs would receive credit for QA of RI change programs?

Evaluation of changes under RG-1.174 for RI programs and 50.59 are well vetted and established.

Site specific seismic risk demonstrations under NUREG-1903 would not be required?

Utilities have addressed plant specific seismic risk as a part of Post-Fukushima Task Force requirements/recommendations Implementation of a modernized 50.46a would be voluntary?

Consistent with 2010 draft 50.46a rule

©2024 Nuclear Energy Institute 9 Overview of Draft Final 50.46c Rule Draft final 50.46c rule was a culmination of Commission directives, research findings, petitions for rulemaking, and public comments

Intended to be a technology-neutral, performance-based, risk-informed, modern rule Major changes proposed in the draft final 50.46c rule, relative to the existing 50.46 rule, shown below Table from SECY-16-0033

©2024 Nuclear Energy Institute 10 Considerations for Improvements to 50.46c Rule Technology-neutral improvements:

Regulation requires rulemaking or exemptions for all new fuel technologies Performance-based improvements:

Regulation does not recognize unique performance aspects of advanced LWR design

Regulation does not recognize unique performance aspects of ATF designs

Regulation maintains prescriptive analytical limits for zirconium cladding Risk-informed improvements:

Risk-informed aspects limited to treatment of debris

Regulation maintains risk-ignorant, deterministic analytical requirements

Industry supports Commission direction in SRM-SECY-16-0033 to apply an appropriate risk-informed regulatory approach to address the research findings on cladding embrittlement

©2024 Nuclear Energy Institute 11 Considerations for Improvements 50.46c Rule Streamlining and removing unnecessary content in the rule is essential to meet the schedule:

Fuel design-specific requirements on performance (50.46c(g)), analytical models (50.46c(d)(2)), and reporting (50.46c(n)) could be moved to regulatory guidance (Draft RG 1.224)

Alternative risk-informed approach for addressing the effects of debris on long-term core cooling (50.46c(e)) and reporting requirements (50.46c(m)(6)-(8)) no longer need to be codified since GSI-191 was successfully closed without new regulation

Industry focus group exercise reduced rule content from 14 pages down to 1.5 pages High-level ECCS performance requirements (50.46c(d)(1)) may need to be more technology-neutral and allow alternate performance metrics for ATF and LWR designs Level of adequate protection for compliance demonstration should be commensurate with risk to public health and safety

Separate performance and analytical requirements above and below transition break size

©2024 Nuclear Energy Institute 12 Implementation of New Requirements Draft final 50.46c rule was designated as adequate protection and exempt from 10 CFR 50.109, Backfitting, requirements

Risk-significance, safety margins, and implementation costs were not considered

Mandatory, regimented implementation schedule Given the low risk profile of postulated LOCAs and existing plant-specific analyses which demonstrate low safety-significance associated with 50.46c research findings, the staffs prior adequate protection exception to the Backfitting Requirements in 10 CFR 50.109 should be reconsidered

Adequate protection exception does not reflect latest revision to Management Directive 8.4, Management of Backfitting, Forward Fitting, Issue Finality, and Information Requests

Implementation costs significantly underestimated Similar to 50.46a, final rule should be a voluntary, alternative to existing 50.46 requirements:

Some plants may not seek enabling changes such as ATF, LEU+, HBU, and/or power uprates and should not incur unnecessary burden to maintain their current licensing basis

Discussion Period

Break

NRCs Phenomena Identification and Ranking Tables for High Burnup Fuel Fragmentation, Relocation, Dispersal, and Its Consequences for Design-Basis Accidents James Corson NRC Office of Nuclear Regulatory Research

Experiments have shown that fuel can fragment during Loss-of-Coolant Accident Current rod average burnup limit = 62 GWd/MTU

Fuel Dispersal PIRT Overview

  • NRC is sponsored a phenomena identification and ranking table exercise to address fuel dispersal and its consequences

- PIRT will help identify areas in need of additional research

- PIRT will also help to develop regulatory criteria related to fuel dispersal

PIRT Process

1. Define the issue that is driving the need for a PIRT
2. Define the specific objectives for the PIRT
3. Define the hardware and the scenario for the PIRT
4. Define the evaluation criterion
5. Identify, compile, and review the current knowledge base
6. Identify phenomena
7. Develop importance ranking for phenomena
8. Assess knowledge level for phenomena
9. Document PIRT results

Fuel Dispersal PIRT Panelists

  • Dave Kropaczek, Veracity Nuclear
  • Wade Marcum, Oregon State University
  • Kurshad Muftuoglu, EPRI
  • Gretar Tryggvason, Johns Hopkins University
  • Wolfgang Wiesenack, Halden Reactor Project (retired)

Scope of PIRT

  • Panelists evaluated impacts of extending burnup beyond 62 GWd/MTU rod-average

- Previous NRC-sponsored PIRTs cover behavior up to 62 GWd/MTU (e.g.,

NUREG/CR-6742 and NUREG/CR-6744 on RIA and LOCA, respectively)

- Goal was to consider what would change when going to higher burnups

Scenarios Evaluated in the PIRT

- Scenario most likely to lead to significant fuel dispersal

- Initiated by a double-ended guillotine break of a large pipe in the reactor coolant system

  • Typically in the recirculation loop in a BWR or the cold leg in a PWR

- Results in rapid loss of coolant, core uncovery, and fuel heatup

  • May lead to fuel rod ductile failure due to ballooning and burst

- Accident mitigated by emergency core cooling system injection to refill the vessel and quench the core

Scenarios Evaluated in the PIRT (2)

  • Reactivity-initiated accidents (RIAs)

- Initiated by a control rod ejection (PWR) or control blade drop (BWR)

- Leads to a rapid power increase in nearby fuel rods, potentially leading to fuel rod failure

- Fuel dispersal would require either very high energy deposition in the fuel (already precluded by limits in Regulatory Guide 1.236) or fuel rod ductile failure

  • Fuel handling accidents

- Initiated by dropping a fuel assembly (i.e., during refueling operations)

- May result in fracture of the rod

- May result in small amount of fuel dispersal, but release mechanism is very different from LOCAs and RIAs

Figures of Merit for the PIRT

  • LBLOCA: fuel coolability and recriticality

- Coolability in terms of both existing embrittlement criteria in 10 CFR 50.46 and in terms of debris bed coolability

- Recriticality only evaluated for small number of phenomena

  • RIA: fuel failure and radionuclide releases
  • FHA: radionuclide releases

PIRT Rankings

  • Panelists ranked phenomena according to importance, knowledge level, and uncertainty

- 123 LBLOCA, 14 RIA, and 6 FHA phenomena ranked

- Items are ranked High (H), Medium (M), or Low (L)

  • Panelists discussed each item to aid in their rankings, but panel consensus was not required

- Instead, tables tally the H, M, and L votes for each item

PIRT Findings: LBLOCA

  • 6 phenomena assigned High importance, Low knowledge level, High uncertainty by majority of panelists

- Transient fission gas release

- Burst opening size relative to the fuel fragment size distribution

- Impact of coolant mass flux on particle mobility

- 3 phenomena related to potential for fuel accumulation on spacer grids

  • Many other phenomena ranked H importance but M/H knowledge level
  • Panelists concluded recriticality likely not an issue

- Also stated that this could be demonstrated using existing neutronics codes

PIRT Findings: RIA

  • Transient fission gas release was the only High importance, Low knowledge level, High uncertainty item (with respect to fuel failure)
  • Several items had H importance but M/H knowledge level

- E.g., core loading pattern and power distributions influence fuel failure but can be calculated accurately

  • Overall, the panel concluded that fuel dispersal would be limited for RIA

- Expectation is that PCMI failures dominate

- PCMI failures characterized by axial split, rather than large openings associated with ballooning and burst

PIRT Findings: FHA

  • No H, L, H items
  • Panel concluded that mechanical fracture would result in minimal release of fuel fragments and additional fission gas

- Some data exists to quantify mass of fuel fragments and fragment size distribution from high burnup fuel under FHA conditions

Conclusions from the Fuel Dispersal PIRT

  • Understanding how much material disperses is crucial to demonstrating coolability

- Key parameters influencing dispersal include transient FGR, fuel fragment size distribution, cladding burst characteristics, spacer grid characteristics, core flow patterns during the transient, and core loading pattern

- Some parameters can be calculated fairly accurately (e.g., core loading pattern, core flow)

- Other parameters are less well known and highly uncertain (e.g., transient FGR, fragment size distribution, burst opening size, impact of spacer grids on debris trapping)

  • Dispersal of fuel fragments remains poorly understood

- However, the panel believes it should be possible to perform simplified analyses to demonstrate coolability so long as the dispersed mass remains low

Conclusions (2)

  • Generally, the Panel members believe that FFRD during a LOCA is unlikely to cause serious coolability issues...

- Conclusion based on expectation that the extent of fuel dispersal would be limited and on current understanding of particle size distribution

- However, many important phenomena have medium or low state of knowledge and high uncertainty, which would affect the amount of fuel dispersed and its impact on coolability

- Experimental and/or analytical work is needed to verify this conclusion

Next Steps

  • NRC is participating in international experimental programs aimed at studying FFRD

- Studsvik Cladding Integrity Project (SCIP) just kicked off its 5th phase this year

- HBU-LOC project under the Second Framework for Irradiation Experiments (FIDES-II) will be performing tests in next couple of years

  • NRC remains engaged with modeling efforts by the national laboratories that seek to quantify the mass of fuel that could be dispersed
  • NRC is incorporating insights from the PIRT in guidance being developed for the increased enrichment rulemaking

High Burnup Workshop Proposed FFRD dose consequence guidance in DG-1425 (Draft Rev 2 of RG 1.183)

Sept 3, 2024

Topics

  • Public Draft Guide Excerpts File (ML24226B262) Related to Proposed FFRD Dose Consequence
  • Regulatory Source Terms and FFRD

- MHA-LOCA

- 50.46 LOCA

- Non-LOCA 55 Different Analyses for Different Defense-in-Depth Purposes

Public Draft Guide Excerpts File Disclaimer:

Draft language being considered by staff, does not have the benefit of full internal review Purpose -

Continued opportunity for early public engagement in the regulatory process Support discussions during this meeting Enable decision-making Support comprehensive communications with the Commission Staff does not intend to formally respond to comments or accept additional comments pertaining to this document, after this meeting Public comment period for the DG will be aligned with the Increased Enrichment Rulemaking (Docket ID NRC-2020-0034, www.regulations.gov) 56

MHA-LOCA and FFRD 57 Regulations: 10 CFR Part 100, 50 and 52.

Required for the purposes of licensing nuclear power plants, that radionuclide releases to reactor containments associated with a substantial meltdown of the reactor core be postulated.

Supports the evaluation of engineered safety features and barriers used to mitigate release of fission products to the environment.

Consequences of these radionuclide releases are evaluated assuming that the containment remains intact and leaks at the design-basis leak rate.

Acceptance Criteria: 25 rem TEDE to an individual at any point on the boundary of the exclusion area boundary for any 2-hour period, 25 rem TEDE on the outer boundary of the low population zone during the entire period of the fission product release passage.

==

Conclusion:==

MHA-LOCA source term bounds FFRD with no need to consider additional radionuclide releases. (Reg 1.183 Rev. 1 provides guidance)

NRC Internal Memorandum (ML21197A067) provides the basis for this conclusion.

Current 50.46 LOCA Analysis 58 Regulation: (GDC - 35, 10 CFR 50.46, and Appendix K to 10 CFR 50)

A design basis accident which establishes a reliable long-term core cooling capability with high-capacity emergency makeup systems.

Ensures the facility could safely cope with a major loss-of-coolant-accident generally from a double-ended guillotine break of the largest pipe in the reactor coolant system.

If the amount of coolant in the reactor is insufficient to provide cooling of the reactor fuel, the fuel would be damaged, resulting in loss of fuel integrity and release of radiation.

If coolant is lost from the reactor coolant system and the event cannot be terminated (isolated) or the coolant is not restored by normally operating systems, it is considered an accident and then subject to mitigation and consideration of potential consequences.

Acceptance Criteria: must be designed so that its calculated cooling performance following postulated loss-of-coolant accidents conforms to the criteria set forth in paragraph (b) of 10 CFR 50.46 for (1) peak cladding temperature, (2) maximum cladding oxidation, (3), maximum hydrogen generation, (4), coolable geometry, and (5) long-term cooling.

==

Conclusion:==

Current 10 CFR 50.46 LOCA analysis do not typically result in appreciable radiological releases. Instead, the normal operation source term is typically utilized.

Proposed 50.46 LOCA and FFRD Analysis

- Assessing radiological consequences from a 50.46 LOCA analysis which predict FFRD appears to conflict with the 10 CFR 50.46 acceptance criteria.

- FFRD-specific source term continues to be difficult to quantify but justifiably bounded by MHA-LOCA source term. NRC Internal Memorandum (ML21197A067) provides the basis for this conclusion.

59

Non-LOCA and FFRD 60 RG 1.183, Rev. 1, Regulatory Position 3.2, states, in part:

At the time of issuance of Revision 1 of this RG, no consensus exists on the mechanism or the computation of TFGR for these events; therefore, future applicants should address this using engineering judgment or experimental data. Though not fully applicable to non-LOCA and non-reactivity-initiated DBAs, NRC Research Information Letter 2021-13, Interpretation of Research on Fuel Fragmentation Relocation, and Dispersal at High Burnup, issued December 2021 (Ref. 29), provides data that can be used to provide a bounding estimate of TFGR for high-temperature DBAs.

==

Conclusion:==

State-of-knowledge for a bounding FFRD source term from a Non-LOCA DBAs has not progressed since issuance of Rev. 1

Feedback and Discussion 61

Environmental Evaluation of ATF with Increased Enrichment and Higher Burnup Levels Donald Palmrose, Ph.D.

Senior Reactor Engineer Office of Nuclear Material Safety and Safeguards (NMSS)

Higher Burnup Workshop V September 3, 2024

Key Points

  • Evaluate environmental impacts of deployment and use of near-term ATF with increased enrichment (IE) and higher burnup (HBU) levels to support future licensing reviews
  • Evaluation of impact in the uranium fuel cycle (UFC), transportation of fuel and waste, and decommissioning
  • Up to 10 wt % U-235 and 80 GWd/MTU for UFC and Decommissioning
  • Up to 8 wt% U-235 and 80 GWd/MTU for transportation of fuel and waste
  • Continued Storage GEIS remains applicable
  • Address release fraction uncertainty at HBU levels Higher Burnup Workshop V September 3, 2024 63

NUREG-2266 Final Report Focus is on near-term ATF technologies

- 1st generation: Coated cladding, doping

- 2nd generation: FeCrAl cladding Longer-term ATF technologies not covered

- UN pellets, SiC cladding, and extruded metallic fuel Near-term ATFs do not significantly change fuel fabrication impacts, radiological inventory, and releases fractions Evaluated the following enrichment and burnup levels:

- Up to 10 wt% U-235 and 80 GWd/MTU for UFC/Decommissioning

- Up to 8 wt% U-235 and 80 GWd/MTU for transportation of fuel and waste Evaluated one-third and half core reloads and provided other clarification based on public comments Higher Burnup Workshop V September 3, 2024 64

Uranium Fuel Cycle UFC observations and impacts were:

- The greater amount of yellowcake to support IE would not cause a significant change in related Table S-3 impacts

- Gaseous centrifuges use less electricity for 10 wt % U-235 than gaseous diffusion did for 4 wt

% U-235

- Longer refueling cycles would reduce the rate of spent nuclear (used) fuel generation

- Spent ATF management would be consistent with Continued Storage (CS) GEIS (NUREG-2157) analysis UFC conclusion is Table S-3 and CS GEIS would bound or still apply to deployment and use of ATF with IE & HBU levels Higher Burnup Workshop V September 3, 2024 65

Transportation of Fuel and Waste Use of DOE & NRC guidance & the code NRC-RADTRAN (radiological transportation risk) with WebTRAGIS (routing)

Six sites selected by NRC Regions

- Region I - Millstone Power Station (PWR)

- Region II - Turkey Point Nuclear Generating Units (PWR), Brunswick Steam Electric Plant (BWR)

- Region III - Enrico Fermi Nuclear Generating Station Unit 2 (BWR) and Dresden Nuclear Power Station (BWR)

- Region IV - Columbia Generating Station (BWR)

Standard PWR and BWR Type B packages selected for fresh fuel Smallest certified Type B packages selected for spent nuclear fuel Higher Burnup Workshop V September 3, 2024 66

Higher Burnup Workshop V September 3, 2024 67

Higher Burnup Workshop V September 3, 2024 68

Transportation of Fuel and Waste Results

  • Normalized annual truck shipments of spent ATF based on 2-yr refueling cycle for 1100 MWe reference NPP of WASH-1238 and Table S-4

- 30 shipments for PWRs and 52 shipments for BWRs

  • Normal, incident-free, conditions are bounded by Table S-4

- Worker doses less than the 4 person-rem of Table S-4

- Cumulative public doses, while generally higher than 3 person-rem of Table S-4 due to increases in populations along routes since WASH-1238 but not a significant impact due to the very low average individual doses

- Average individual doses were <<1 mrem and within the Table S-4 ranges of doses for onlookers and along route populations

  • Radiological accident risks still small as in Table S-4
  • Non-radiological accident risk (fatalities/injuries) greater than radiological risks but also bounded by Table S-4 Higher Burnup Workshop V September 3, 2024 69

Decommissioning Decommissioning GEIS - NUREG-0586 Supplement 1

- Extensively discussed in 2013 and 2024 License Renewal GEIS (NUREG-1437 Rev 1 and 2) and in past new reactor EISs ATF deployment, use, and subsequent termination of operations would only affect human health and waste management

- All other resource areas would be the same or slightly less ATF deployment effects on decommissioning:

- Effluent releases would still be lower after cessation of ops

- Worker doses still controlled per 10 CFR Part 20

- Would not alter the practices employed to manage the wastes

- Would need less ISFSI capacity than staying with current fuels Decommissioning GEIS would bound deployment and use of ATF with IE and HBU levels Higher Burnup Workshop V September 3, 2024 70

Guidance for Analysts

  • If > 8 wt% U-235 enrichments, new transportation analysis could apply the methodology in Section 3 using the data sources documented in Appendix A through Appendix D
  • If > 10 wt% U-235 enrichment, assess uranium fuel cycle and decommissioning impacts by applying the rationale in Sections 2 and 4, respectively
  • If > 80 GWd/MTU, appropriate revised transportation radiological releases needs to be evaluated and applied in the transportation analysis along with assessing the related changes (if any) in spent fuel management to the Continued Storage and Decommissioning GEISs
  • The staff encourages potential applicants to discuss the above as part of any pre-application discussions Higher Burnup Workshop V September 3, 2024 71

72 Spent Fuel Pool 2024 A Regulatory Perspective Kent Wood U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation High Burnup Workshop September 3, 2024

73 Overview

  • RegGuide 1.240
  • ATF/IE/HBU
  • Key Considerations Picture: Spent Fuel Pool

74 Guidance

- March 2021 ML20356A127

- Endorsed NEI 12-16, R4

- clarifications and exceptions

  • o guidance based on experience with LWR fuel to that point.

75 ATF/IE/HBU

  • ATF/IE/HBU

- ATF: which are you implementing?

- IE: U235 up to 10 wt/% enriched?

- HBU: up to 80 GWD/MTU?

- What guidance from Reg Guide 1.240 and NEI 12-16 R4 applies?

76 ATF/IE/HBU

- Vogtle ATF/IE LTAs

  • Exemption to 10CFR50.68(b)(7): Enrichment
  • Doped Fuel =>Increased Theoretical Density => more fissile material

- Byron and Braidwood

  • Full Batch
  • 6.5 wt/% U235

77 Key Considerations

  • Depletion codes

- Limitations and Conditions

  • What does your future look like?

- Transition cores

- Equilibrium cores

  • Existing work
  • References/Precedents

78 Key Considerations

  • Fuel assembly physical changes

- e.g. pellet diameter, fuel rod diameter

  • Changes in Operation

- e.g. load following

- Recommended well ahead of submittal

- Novel and Unique situations

  • Early and maybe more than one
  • High quality submittals

ORNL is managed by UT-Battelle LLC for the US Department of Energy Oak Ridge National Laboratory: High Burnup Summary Nathan Capps, cappsna@ornl.gov Technical Team: Jason Harp, Peter Doyle, Yong Yan, Bob Morris, Chuck Baldwin, Mackenzie Ridley, Diego Muzquiz

22 Strategy to Enable Burnup Extension Goal Strategy NRC RIL 2021-13 Enable and expand the safe and economic operation of the US LWR fleet beyond the current regulatory limits by developing the capabilities and performing the necessary research to support fuel performance beyond 62 GWd/tU Perform integral and semi-integral LOCA testing All five elements Develop in-situ data acquisition capabilities for performance and safety-critical phenomena (e.g.,

transient FGR, strain, strain rate, etc.)

Element 1, 2, and 4 Determine the impact of irradiation conditions on microstructure changes governing fuel and cladding response at the macro-scale Element 1, 2, and 4 Develop characterization to model or limit dispersal mass Element 3

33 Semi-Integral LOCA Testing Parameter HBR#1 NA#1 NA#2 HBR#2*

NA-GS 6XV+-

Fuel H.B.

Robinson North Anna North Anna H.B. Robinson North Anna Byron Materials Zry-4 M5 M5 Zry-4 M5 Protected Father rod burnup (GWd/MTU) 66.5 63 68.5 66.5 63 73.7 Outside diameter (mm) 10.77 9.5 9.5 10.77 9.5 9.144 Wall thickness (mm) 0.76 0.57 0.57 0.76 0.57 0.575 Internal pressure at 300°C (MPa) 8.27 8.27 8.27 8.27 8.2 8.27, 11.0, 13.8 Temperature ramp from 300°C (°C/s) 5 5

5 5

5 5

Temperature at burst

(°C) 770 791 816 770 861 Protected Terminal temperature

(°C) 1,000 1,200 1,000 1,000 1000 900 Burst shape Oval Oval Oval Oval Oval/Oval Oval Burst length (mm) 7 16 8.4 4.7/5.6 24.6/TBD/22.9 Max. burst width (mm)

~2

~3 1.5 0.64/0.64 8.5/TBD/9.1 Max strain (C/Cm)max (%)

25 41 20 41 Protected

  • Segment length = 7.9

+Segment Lenth = 8.5

-PIE in progress

44 Summary: Removed Fuel Sieving

  • Total fragment size distribution

- Cut sample and dumped all mobile material

  • Additional steps were taken to assess dispersal
  • Ongoing PIE on remaining LOCA tests 0

5 10 15 20 25 30 35 40 45 2mm 1mm 500µm 250µm 125µm Mass (g)

NA#1 NA#2 HB#1 HB#2 6XV-1200

55 In-Cell Grid Spacer Test Conditions

  • Single spacer segment fits within quartz reaction tubing
  • Configuration 1: Cr/Zry & Zry
  • Configuration 2: Zry
  • 1200 psi, open valve
  • 5°C/s ramp rate until rupture

66 Out-of-Cell Benchmark for In-Cell Test TC TC Collar

  • Thermocouple above and below simulated spacer grid (worm clamp)
  • Rupture at lower TC 2 below cladding centerline
  • Estimate ~100°C delta T through the SS collar
  • Simulated grid spacer restricted cladding diametric strain Experimental results consistent with Modeling Predictions Cladding Diametric Strain 3D Scan of Rupture Opening

77 Burst 1 0.55 above clamp Burst 2 at centerline of sample Burst 2 Opening Length = 0.220 Width = 0.025 OD at 0: 0.483 at 90°: 0.458 Burst 1 Opening Length = 0.185 Width = 0.025 OD at 0: 0.505 at 90°: 0.470 Clamp: 2 above sample centerline.

88 Cladding Strain Threshold

  • Generally, agrees with the NRC RIL on FFRD

- Key Difference: Results suggest there may be a threshold more applicable to the top and bottom

- More data needed to verify Strain Threshold Bottom = 8.16%

Top = 12.5%

99 Transient Fission Gas Release Parameter 651F3D 6XV-A3 NA-GS Arrested FGR Fuel North Anna Byron North Anna North Anna Sample burnup (GWd/MTU) 68.5 75 71 68 Segment Length

~two pellets

~two pellets 12 12 Applied Pressure Cladding Constraint Cladding Constraint 8.2 MPa 6.2 MPa Temperature ramp from 300°C (°C/s) 5 5

5 5

Temperature Conditions

(°C)

Stair Step LOCA LOCA Stair Step Terminal temperature

(°C) 1,000 1,000 1000 burst Fission Gas Released

(%)+

10.7

~12 5.1**

TBD

  • Tentatively scheduled for October 2024

+Results are approximations and need detailed neutronics to verify

    • Preliminary 651F3D : As-Irradiated Post-Test 651F3D 651F3D

10 10 10 Additional tFGR Test (Test 2)

  • Standard LOCA Ramp on 33.5 mm segment unpressurized
  • 15.6 mCi of Kr-85 Released
  • Roughly 12% FGR 0

200 400 600 800 1000 1200 0.0E+00 2.0E+03 4.0E+03 6.0E+03 8.0E+03 1.0E+04 1.2E+04 1.4E+04 1.6E+04 1.8E+04 2.0E+04 0

1000 2000 3000 4000 5000 6000 7000 8000 Activity (uCi)

Elasped Time (s)

Kr-85 Activity Versus Time with Flow Delay Ratemeter Trap Inventory Begin Trap WarmUp Temperature Trap fills as quartz tube is flushed Warming trap to discharge inventory Temperature (C)

11 11 11 Further Analysis of Release Fission Gas (6XV-A3)

  • It is possible to analyze the released Kr and Xe isotopes to determine the fraction
  • The ratios collected in this test suggest most fission (~67%) was from Pu-239

- (134Xe+132Xe+131Xe)/(86Kr+84Kr+83Kr)

- Whole rod was ~50% Pu-239 Fission (73.8 MWd/kgU) from Neutronics

  • Agrees with microscopy from the initial test Further Analysis of Release Fission Gas (6XV A3) 0 200 400 600 800 1000 1200 1.00E-13 1.00E-12 1.00E-11 1.00E-10 0

10 20 30 40 50 60 70 Temperature (°C)

Signal Strength Time (minutes)

Mass 134 Mass 86 Temperature 6XV-A3A

12 12 12 LOCA Temp & pressure Fission gas released during the LOCA (NA-GS)

  • First High Burnup LOCA test to measure FGR during a LOCA test
  • Appeared to have minimal impact on cladding rupture
  • Preliminary FGR Results

= 5.1%

  • Full length heating test suggest similar results (more to come)

13 13 13 Post LOCA Dispersal Behavior: Out-of-cell Test Results

  • HfO2 and W, in various mixtures, has been tested from 2 - 25 Hz and 25 - 0.3 mm amplitude vibrations
  • Dispersal limited to conditions with only small particles, very large bursts (>5 mm) or mixtures with large fractions

(>25%) of small (<1 mm) particles

  • Studies on particle shape effects, burst geometry, and an international collaboration are ongoing for the coming FY
  • Out-of-cell testing shows limited dispersal with typical LOCA-induced burst sizes 2.4 - 4mm 1.7 - 2.4mm 0.8-1.7mm Tungsten:

HBU-relevant mix (40:40:20)

HfO2:

Even mix: 4 mm - 0.25 mm particles 7 mm wide burst (all other points, 5 mm wide burst) 40:20:40 60:15:25 Mixes with 2 mm, 1 mm, 0.5 mm particles 40:40:20

14 14 14 Post LOCA Dispersal Behavior: Out-of-cell vs. In-Cell Test Results

  • Post-LOCA sample was tested under representative conditions intended to replicate expected LOCA forces during post burst conditions
  • Sample had a relatively large burst opening and all post-burst dispersal occurred during sample loading
  • Burst-dispersal was found to be similar to FRIAR dispersal and both represented <20% of dispersible, but retained, fuel fragments
  • In-cell testing showed the surrogate testing was conservative

15 15 15 Impact of Hydrogen on LOCA Performance

-5

-4

-3

-2

-1 mm

~950 wppm H Baseline 0

20 µm 20 µm Rupture Rupture Rupture Rupture Rupture Rupture Baseline Baseline Baseline

~950 wppm H

~950 wppm H

~950 wppm H Craters Craters Craters 3D Optical Imaging Electron Imaging Hydrogen charged claddings show evidence of less ductile rupture events

16 16 16 Measurable decreases in rupture temperature and maximum diameter strain values with increasing H content

~10°C drop in rupture temperature for every 100 wppm H added Material Type - Cameco Zry-4

17 17 17 Future Work

- Complete PIE on current rods

- Planning upwards of 10-20 test next FY across various programs

  • Mechanical Testing

- Evaluate changes in mechanical properties at higher burnups

- Connect in-reactor to test reactor performance

- Expand evaluation to mechanical testing

- Assess other accident scenarios (i.e., RIA via MBT and expansion due compression

  • Begin assessing high burnup ATF performance

Discussion Period

Public Comment Period

Adjourn