Summary of March 28, 2024, Meeting with Nuclear Energy Institute Concerning NEI 20-07, Draft Revision E
ML24227B030
Person / Time
Site: 99902028
Issue date: 10/22/2024
From: Edwards T
Licensing Processes Branch
To: Gerond George
Licensing Processes Branch
Shared Package
ML24227B029 List:
References
EPID L-2023-NFN-0012
Download: ML24227B030 (1)


Text

October 22, 2024 MEMORANDUM TO: Gerond A. George, Chief Licensing Projects Branch Division of Operating Reactors Licensing Office of Nuclear Reactor Regulation FROM:

Theo Edwards, Project Manager /RA/

Plant Licensing Branch 1 Division of Operating Reactors Licensing Office of Nuclear Reactor Regulation

SUBJECT:

SUMMARY

OF MARCH 28, 2024, PUBLIC MEETING WITH NUCLEAR ENERGY INSTITUTE CONCERNING NEI 20-07, DRAFT REVISION E (EPID L-2023-NFN-0012)

On March 28, 2024, a partially closed public meeting was held between the U.S. Nuclear Regulatory Commission (NRC) staff and representatives of Nuclear Energy Institute (NEI) at NRC headquarters in Rockville, Maryland. The purpose of the meeting was for the NRC staff and NEI representatives to discuss the NRC staffs comments on Draft Revision E of NEI 20-07, Guidance for Addressing Common Cause Failure in High Safety-Significant Safety-Related Digital I&C Systems. The draft NEI 20-07 was provided to the NRC by NEI in a letter dated July 24, 2023. A copy of the document is available in the Agencywide Documents Access and Management System (ADAMS) at Accession No. ML23205A188. The presentation NEI used during the meeting is available in ADAMS at Accession No. ML24103A153. The NRC staffs comments on NEI 20-07, Draft Revision E, are available in ADAMS at Accession No. ML24081A025. The meeting notice and agenda, dated March 18, 2023, are available in ADAMS at Accession No. ML24078A080. A list of attendees is provided in the enclosure.

During the meeting, the NEI representatives described their understanding of the NRC staffs feedback and provided their response to the NRCs feedback on NEI 20-07, Draft Revision E.

Specifically, NRC staffs comments 2, 3, 4, 5, 7, 8,15, 18, 24, 25, 28, 33, 35, 36, 38, 39, 40, 46, 47, 48, 50, 57, 58, 59, 60, 62, 63, 66, and 67 were discussed during the meeting. The NEI representatives spoke more broadly about, Electric Power Research Institute (EPRI) products described in NEI 20-07, the meaning of credible and likely sources, NRC staff discussed defined terms and their direct source in NRC approved standards. NEI has described an interest for NEI 20-07 to have considerations of advanced reactors, a sufficient of the level of detail describing the methods in the draft document, and a level clarity to demonstrate the efficacy of the methods in the draft document.

CONTACT:

T. Edwards, NRR (301)-415-1721

G. George The NEI representatives stated that NEI 20-07 is intended to be technologically inclusive and applicable to current light water, new light water, and advanced reactors. Through the course of the conversation, the NRC staff focused on the inclusion of reference to EPRIs digital engineering guideline, hazards and consequence analysis in digital systems (HAZCADS), and digital reliability analysis methodology (DRAM). The NRC staff asked the NEI representatives for examples where HAZCADS and DRAM has been used by the nuclear industry. The NRC staff asked if NEI would conduct a tabletop exercise demonstrating the application of the methods in the draft document. The NEI representatives offered to facilitate a meeting with EPRI DRAM experts to demonstrate the use of some of the methods described in NEI 20-07, Draft Revision E. The NEI representatives expressed interest in at least two more meetings to continue the discussion of NRC staff comments on NEI 20-07, Draft Revision E.

No regulatory decisions were made during the meeting. Public Meeting Feedback forms were not received.

Please direct any inquiries to Michael Marshall 301-415-2871 or michael.marshall@nrc.gov or me at 301-415-1721 or theo.edwards@nrc.gov.

Project No: 99902028

Enclosure:

List of Attendees

Enclosure LIST OF ATTENDEES MARCH 28, 2024, MEETING WITH NUCLEAR ENERGY INSTITUTE CONCERNING NEI 20-07, DRAFT REVISION E Name Organization Steven Alferink U.S. Nuclear Regulatory Commission (NRC)

Christina Antonescu NRC Sergiu Basturescu NRC Norbert Carte NRC Calvin Cheung NRC Christopher Cook NRC Samir Darbali NRC Theo Edwards NRC Leslie Fields NRC Ian Jung NRC Omar Lopez NRC Michael Marshall NRC Tania Martinez Navedo NRC David Rahn NRC Gilberto Blas Rodriguez NRC Fanta Sacko NRC Dinesh Taneja NRC Sunil Weerakkody NRC Steve Wyman NRC Alan Campbell Nuclear Energy Institute Warren Odess-Gillett Westinghouse Electric Corporation Mark Samselski Constellation Energy Generation, LLC Suzanne Loyd Constellation Energy Generation, LLC Philip Tarpinian Constellation Energy Generation, LLC Neil Archambo Jana Bergman Curtiss-Wright Corporation Zachary Ballert Jensen Hughes Vanover, Donald Jensen Hughes Brian L Mount Dominion Energy, Inc.

Package ML24227B029 Meeting Notice ML24078A080 Meeting Summary ML24227B030 OFFICE NRR/DORL/LPL1/PM NRR/DORL/LPL1/PM NRR/DORL/LLPB/LA NAME TEdwards MMarshall DHarrison DATE 9/3/24 9/25/24 10/17/24 OFFICE NRR/DORL/LLPB/BC NRR/DORL/LPL1/PM NAME GGeorge TEdwards DATE 10/21/24 10/22/24