MONTHYEARML24228A2102024-08-20020 August 2024 2024 NEI Early Warning System (EWS) Presentation - NEI Slides ML24229A0012024-08-19019 August 2024 NEI - Spent Fuel Management: Safety and Efficiency Improvements Through Technology and Performance Margins - NRC PIRTs Public Meeting Rev. 8.15.2024 Final ML24218A1832024-07-30030 July 2024 NEI 7-30-24 Trial Use RG 1.247 Path Forward Final ML24197A0652024-07-17017 July 2024 SDP Realism Public Meeting NEI Presentation ML24172A1952024-06-27027 June 2024 NEI Slides for 06-27-2024 Public Meeting Structures as IROFS at Fuel Cycle Facilities ML24178A0372024-06-26026 June 2024 NRC Power Uprate Review Preparation June 26, 2024 Public Meeting Slides ML24164A1972024-06-17017 June 2024 Public Meeting Slides - NRC Staff Comments and Observations on NEI 10-01, Rev 2 Industry Guideline for Developing a Plant Parameter Envelope in Support of an Early Site Permit ML24130A1972024-05-0909 May 2024 NEI Presentation Slides on Rapid and Large-Scale Nuclear Reactor Deployments for Remote Industrial Applications - May 14 2024 Public Meeting ML24129A1382024-05-0808 May 2024 NEI Slides on Centralized Inspections for May 9, 2024 Public Workshop ML24114A1142024-04-18018 April 2024 NEI Supplemental Information on NRC Comments on NEI 20-07, Draft Revision E - April 18 Meeting (Non-Proprietary) ML24103A1532024-04-12012 April 2024 NEI Supplemental Information on NRC Comments of NEI 20-07 Rev E (Non-Proprietary) - Slides ML24092A3132024-04-0303 April 2024 Public Mtg_2024-04-03 Pre-submittal Meeting with the Nuclear Energy Institute (NEI) to Discuss an Update to NEI 03-12, Security Plan Template (Revision 8)_NEI Slides ML24088A2252024-03-26026 March 2024 NEI Slides for Centralized Inspections March 2024 ROP Public Meeting ML24075A2092024-03-14014 March 2024 NEI Advanced Reactor Di&C Task Force Slides - Accident Monitoring Instrumentation ML24075A2102024-03-14014 March 2024 NEI Alan Campbell Slides - Non-Safety-Related with Special Treatment – Digital Considerations ML24082A1792024-03-14014 March 2024 RIC-2024 TH18 True Slides ML24086A5342024-03-14014 March 2024 RIC 2024 TH23 Slides - the Industry’S Innovation Imperative ML24067A2592024-03-13013 March 2024 RIC-2024 W14 Slides - NEI-BHoltzman an Industry Perspective on Advanced Reactor Construction Oversight ML24067A0062024-03-0808 March 2024 1 - NRC - Workshop3 - Non-LOCA Release Fractions Feedback - Final ML24067A0072024-03-0808 March 2024 2 - NRC - Workshop3 - Non-LOCA - FFRD - Final ML24067A0092024-03-0808 March 2024 3 - NRC - Worshop3 - CR Dose Presentation - Final ML24067A0102024-03-0808 March 2024 4 - NRC - Workshop3 - EQ Presentation - Final ML24067A0122024-03-0808 March 2024 6 - NRC - Workshop3 - Best Estimate Dose ML24067A0132024-03-0808 March 2024 7 - NRC - Workshop3 - Closing Remarks ML24067A2882024-03-0808 March 2024 1 (Revised)-NRC_Workshop3_Non-LOCA Release Fraction Feedback-Final ML24016A2372024-01-17017 January 2024 NEI Environmental Reviews Slides Public Meeting 1-17-24 ML24010A0202024-01-11011 January 2024 Public Meeting on SLR Efficiencies - NEI Presentation ML24008A0442024-01-0909 January 2024 NEI - Slides for NRC Workshop 1 on Revision to RG 1.183 R1 - Final - ML24008A044 ML23342A0262023-12-14014 December 2023 December 14, 2023, Presentation on NEI 23-01 Operator Cold Licensing Training Plan for Advanced Nuclear Reactors ML23347A1782023-12-13013 December 2023 12-14 NEI EPRI Presentation NRC Public Meeting 16-03 R1 ML23303A1922023-10-30030 October 2023 NEI Slides for SLR Public Meeting - Oct 31 2023 ML23324A2392023-10-24024 October 2023 S1P6 - Hilary Lane - NRC AMT Workshop - Oct. 2023 ML23261C3792023-09-27027 September 2023 NEI 22-04 Pre-Submittal Meeting with NRC - September 27, 2023 ML23258A1992023-09-20020 September 2023 NEI 99-02 Draft Rev. 8 Update for Sept 2023 ROP Public Meeting ML23242A0782023-08-30030 August 2023 Hbu Workshop IV Industry Presentation: Drive to Deploy ATF with Increased Enrichment and Higher Burnup ML23242A1662023-08-30030 August 2023 the Future of Nuclear Power: 2023 Baseline Survey (Slides) ML23230A0142023-08-22022 August 2023 Industry Slide Presentation for 8-22-23 Meeting on ARCAP-TICAP and DG-1404 Guidance Documents ML23228A0042023-08-18018 August 2023 NEI Slides for Public Meeting to Discuss Possible Efficiencies on the Subsequent License Renewal Review - August 18, 2023 ML23191A0162023-07-11011 July 2023 NEI Comments on Risk-Informed Process for Evaluation (RIPE) DORL TSG - 7/11/23 Public Meeting Slides from NEI ML23191A0632023-07-0707 July 2023 NEI Cybersecurity Presentation for July 2023 ROP Public Meeting ML23191A0662023-07-0707 July 2023 NEI 99-02 Draft Rev. 8 Update for July 2023 ROP Public Meeting ML23160A1512023-06-15015 June 2023 25 - Industry - Industry Perspectives on ASME III and XI Pre-Service Inspection ML23160A1422023-06-15015 June 2023 20 - Industry - Industry Perspective on Performance Monitoring ML23116A1892023-05-31031 May 2023 Industry Observations of NRC Licensing Program (NEI Slides May 2023) ML23136A5912023-05-18018 May 2023 NEI Safety Culture Presentation for May 2023 ROP Public Meeting ML23125A3192023-05-0909 May 2023 NEI Presentation for May 9, 2023, Public Meeting on NEI 22-05, Revision a ML23117A3712023-05-0202 May 2023 NEI Lessons Learned Meeting Slides, May 2, 2023 ML23115A0302023-04-27027 April 2023 NEI Perspective on Performance Monitoring in Use of Probabilistic Fracture Mechanics for Optimizing Inspections of Non-RPV Pressure Vessels, April 27, 2023 ML23088A0822023-03-30030 March 2023 NEI Presentation - March 30, 2023 PRA Configuration Control Public Meeting ML23082A0572023-03-28028 March 2023 Proposal to Establish Alternate Requirements for Components Commensurate with Safety and Risk 2024-08-20
[Table view] |
Text
Industry Lessons in Decommissioning Project Management J o h n S a u g e r, E n e r g y S o l u t i o n s Jeff Dostal, Holtec
Carrying Zion Lessons Forward Lesson Learned:
A sacrificial soil layer was relied on to capture any contamination from Class A waste piles.
Inside containment, waste processing tents with a layer of geo textile was used with an asphalt pad inside, and a negative pressure, HEPA-filtered ventilation system.
The tented structures were adequate, but the sacrificial soil approach required changes.
©2023 Nuclear Energy Institute 2
Carrying Zion Lessons Forward (cont.)
Improvements implemented:
No waste is no loner allowed to be stored outside in weather.
Haul paths to waste processing structures are scanned weekly.
Waste processing facility openings undergo face velocity analysis to determine what site wind conditions support maintenance of a negative pressure envelope.
Waste production schedules were changed to flatten the waste production and transportation curve during decommissioning, eliminating the need to stockpile.
These improvements are producing results as expected and will be continued at west coast and ES owned facilities.
©2023 Nuclear Energy Institute 3
Managing RV Internals Cutting Debris Lesson Learned:
Once fuel has been moved to the ISFSI, the largest remaining source term in the plant is the Reactor Vessel Internals. Less than adequate chip management (chips are creating during mechanical cutting of internals components) can result in chips moving outside the cavity.
©2023 Nuclear Energy Institute 4
Managing RV Internals Cutting Debris (Cont.)
Lessons incorporated at other facilities:
More extensive rinsing of class A, B/C liners before being placed in a shipment cask. This is followed up by smears looking for chips.
Raised standards and metrics for chip collection at facilities going through RVI work.
Development of plans, strategies, and processes to collect any residual chips during equipment removal such that they can be consolidated for removal, packaging, and shipment.
Design modifications for all T-bell designs to prevent mechanical over travel.
©2023 Nuclear Energy Institute 5
LTP Complexity As the largest commercial nuclear facility decommissioned, Zion submitted in excess of 40,000 pages associated with the LTP, release records, and RAI responses. Efforts must be undertaken to streamline submittals and where possible, organize data such that reviewers can follow the string from generation of site specific DCGLs, hard to detects, survey design etc.
NEI suggests a followup session where suggestions can be discussed and considered around organization of data and reports.
©2023 Nuclear Energy Institute 6
Workforce As an industry we are dealing with an aging workforce. License termination is a highly technical, specialized process that requires years of experience and mentoring to create competent professionals for this field. NEI members have had success in hiring and developing new talent through a combination of advanced, specialized graduate level courses, extensive training, and development of training materials that incorporate qual cards, etc.
What can NEI members do to share our results of these efforts with NRC, including providing reference materials?
©2023 Nuclear Energy Institute 7
Lessons from Oyster Creek Waste Reduction in the Decommissioning Process
- Recycling / Reuse of material and components
- Isolation and segmentation of higher waste class materials
- Reduction of processes that Result in Generation of Additional Waste Use of Innovation to improve Worker Safety and Efficiency
- Dose Reduction through remote operation
- Mitigating High Heat Stress Conditions
©2023 Nuclear Energy Institute 8
End of Indsutry Presentation 1 Lessons in License Termination Planning and Execution B i l l B a r l e y, S o u t h e r n C a l i f o r n i a E d i s o n Jean Fleming, Holtec Sarah Roberts, Energy Solutions
Licensee and NRC communication Early engagement with NRC for LTP NRC reviewer front-end involvement for site familiarity Regional involvement in QA/QC of LTP/FSS processes Direct interaction on RAI clarification between licensee and HQ reviewers/PM
©2023 Nuclear Energy Institute 11
Consistent quality products for LTP and reports Review of recent RAIs and incorporation into LTP submittal Utilize checklists for LTP submittals and reports for completeness Goal of NEI 22-01 to drive consistency
©2023 Nuclear Energy Institute 12
Need to streamline LTP and FSS reports to restrict copious amount of verbiage and data in submittals Utilize QA/QC of programs to limit data requirements Similarly, characterization data could be limited in LTP submittals Define limits to stand alone for reports
©2023 Nuclear Energy Institute 13
End of Industry Presentation 3