1 Comparison of 2020 Version of Kyoto SAR and 2021 Version of Kyoto SAR vs NEW 2022 version of JAEA SAR Comparison Table Chapter J/170/B(U)F-96 (2020 version of Kyoto)

(USA/0835/B (U) F-96, Rev. 0 Expires 4/26/25)

Chapter J/2039/B(U)F (2021 version of Kyoto)

(USA/0841/B (U) F, Rev. 0 Expires 12/8/26)

NEW J/2043/B (U) F (2022 version of JAEA)

Entirety of SAR Contents of Fuel Information Kyoto University Fuel JAEA Fuel:

JMTR, JRR-3, JRR-4 and JMTRC Entirety of SAR Contents of Fuel Information Kyoto University Fuel Spectrum Converter (Kyoto)

Contents of Fuel Information FUEL CONTENTS PREVIOIUSLY AUTHORIZED - NO CHANGE:

Fuel of JAEA Previously Authorized in J/170/B (U) F-96:

JRR-3, JMTR, and JMTRC FUEL CONTENTS DELETED:

Kyoto University Fuel Spectrum Converter (Kyoto)

JMTR MEU Fuel JMTRC HEU Follower Fuel JRR-4 Fuel N/A N/A

()-A (14)

The information added to this report is as follows:

Planned years of use (60 Years)

PLANNED YEARS OF USE PREVIOUSLY AUTHORIZED - NO CHANGE:

Planned Years of Use Previously Authorized in J/2039/B (U) F (Planned years of use (60 Years))

2

()-A.4.4

()-F Hoisting accessory:

Consideration of fatigue of hoisting accessory A chapter (II)-F: Consideration of Aging of Nuclear Fuel Package was added.

HOISTING ACCESSORY PREVIOUSLY AUTHORIZED - NO CHANGE:

Hoisting accessory:

Consideration of fatigue of hoisting accessory was Previously Authorized in J/2039/B (U) F AGING CHAPTER PREVIOUSLY AUTHORIZED - NO CHANGE:

A chapter (II)-F: Consideration of Aging of Nuclear Fuel Package was previously authorized in J/2039/B (U) F.

()-A Structural Analysis A.5.3 Drop test of fuel plate Kyoto University N/A STRUCTURAL ANALYSIS PREVIOUSLY AUTHORIZED - NO CHANGE:

Structural Analysis Previously Authorized in J/170/B (U) F-96.

Deleted: Drop test of fuel plate (Kyoto University) was deleted.

()-A Structural Analysis A.10.10 Mechanical characteristic of JRR-4B Fuel Plate Deleted Deleted STRUCTURAL ANALYSIS PREVIOUSLY AUTHORIZED - NO CHANGE:

Structural Analysis Previously Authorized in J/170/B (U) F-96.

Deleted: Mechanical characteristic of JRR-4B Fuel Plate

3

()-B Thermal Analysis

()-B THERMAL ANALYSIS PREVIOUSLY AUTHORIZED - NO CHANGE:

Thermal Analysis previously authorized in J/170/B (U) F-96.

(II)-C Containment Analysis CONTAINMENT ANALYSIS - CHANGE IN LEAK RATE Change in Leak Rate Table. C.12, Table C.15:

Because certain JMTRC fuel used for the leak rate calculation was deleted, another previously authorized JMTRC fuel element was used for the leak rate calculation, and consequently the leak rate changes from both the J/170/B (U) F-96 and J/2039/B(U)F SARs. However, the leak rate under the accident conditions remains less than the reference value, consistent with the previous authorizations.

()-D Shielding Analysis

()-B SHIELDING ANALYSIS PREVIOUSLY AUTHORIZED - NO CHANGE:

Shielding Analysis previously authorized in J/170/B (U) F-96.

4

()-E Criticality Analysis Target of criticality evaluation (Fig.E.8 Fuel of Kyoto university Fuel of JAEA:

JMTR, JRR-3, JRR-4 and JMTRC

()-E Target of criticality evaluation Fuel of Kyoto university Spectrum converter CRITICALITY ANALYSIS PREVIOUSLY AUTHORIZED - NO CHANGE:

Target of criticality evaluation (Fig.E.8 Fuel of JAEA was target of criticality evaluation and Previously Authorized in J/170/B (U) F-96:

JRR-3, JMTR and JMTRC Regulations for the Safe Transport of Radioactive Material 2012 Entirety of SAR 2018 2018 PREVIOUSLY AUTHORIZED IN J/2039/B (U) F - NO CHANGE.