L-2023-037, Annual Radioactive Effluent Release Report

From kanterella
(Redirected from ML23060A301)
Jump to navigation Jump to search
Annual Radioactive Effluent Release Report
ML23060A301
Person / Time
Site: Turkey Point  NextEra Energy icon.png
Issue date: 03/01/2023
From: Strand D
Florida Power & Light Co
To:
Office of Nuclear Reactor Regulation, Document Control Desk
References
L-2023-037
Download: ML23060A301 (1)


Text

March 1, 2023 L-2023-037 10 CFR 50.36a U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D. C. 20555 RE:

Turkey Point Nuclear Plant, Unit 3 and 4 Docket Nos. 50-250 and 50-251 Renewed Facility Operating Licenses DPR-31 and DPR-41 2022 Annual Radioactive Effluent Release Report Pursuant to 10 CFR 50.36a(a)(2) and Technical Specification (TS) 6.9.1.4, enclosed is the 2022 Annual Radioactive Effluent Release Report for St. Lucie Units 1 and 2. The report provides information for the 12-month period beginning January 1, 2022 and ending December 31, 2022.

If you have any questions regarding this submittal, please contact Kenneth Mack at 561-904-3635.

Sincerely, Dianne Strand General Manager, Regulatory Affairs Florida Power & Light Company

Enclosure:

Annual Radioactive Effluent Release Report cc:

USNRC Regional Administrator, Region II USNRC Project Manager, St. Lucie Nuclear Plant USNRC Resident Inspector, St. Lucie Nuclear Plant Dianne Strand

ENCLOSURE ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT (48 pages follow)

2022 -- Turkey Point Annual Radioactive Effluent Release Report Table of Contents 1.0 REGULATORY LIMITS................................................................................ 3-4 2.0 EFFLUENT CONCENTRATION...................................................................... 4 3.0 AVERAGE ENERGY....................................................................................... 4 4.0 MEASUREMENTS AND APPROXIMATIONS OF TOTAL ACTIVITY 4-6 5.0 BATCH RELEASES........................................................................................ 6 6.0 UNPLANNED RELEASES..............................................................................6 7.0 REACTOR COOLANT ACTIVITY.................................................................... 7 8.0 SITE RADIATION DOSE................................................................................. 7 9.0 OFFSITE DOSE CALCULATION MANUAL (ODCM) REVISIONS.................. 8 10.0 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS................................. 8 11.0 PROCESS CONTROL PROGRAM REVISIONS..............................................8 12.0 INOPERABLE EFFLUENT MONITORING INSTRUMENTATION...................8 13.0 GROUNDWATER SAMPLING........................................................................8 UNIT 3 TABLES......9-22 UNIT 4 TABLES23-36 SITE DOSE TABLE..37-39 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS TABLE....40- 47 ATTACHMENT A-OFFSITE DOSE CALCULATION MANUAL......48 Page 2 of 48 14.0 ERRATA DATA.................................................................................................8

2022 -- Turkey Point Annual Radioactive Effluent Release Report 1.0 REGULATORY LIMITS 1.1 Liquid Effluent (a)

The concentration of radioactive material released in liquid effluents to unrestricted areas shall not exceed ten times the concentration specified in 10CFR20 Appendix B, Table 2, Column 2 for radionuclides other than dissolved or entrained gases. For dissolved or entrained noble gases, the concentration shall not exceed 2.0E-04 micro-curies per milliliter total activity.

(b)

The dose or dose commitment per reactor to a member of the public from any radioactive materials in liquid effluents released to unrestricted areas shall be limited as follows:

During any calendar quarter, to less than or equal to 1.5 mrem to the total body and less than or equal to 5 mrem to any organ.

During any calendar year, to less than or equal to 3.0 mrem to the total body and less than or equal to 10 mrem to any organ.

1.2 Gaseous Effluent (a)

The dose rate due to radioactive materials released in gaseous effluent from the site to areas at and beyond the site boundary shall be limited to the following:

Less than or equal to 500 mrem per year to the total body and less than or equal to 3000 mrem per year to the skin due to noble gases.

Less than or equal to 1500 mrem per year to any organ due to Iodine 131 (I-131), Iodine 133 (I-133), tritium (H-3), and for all radioactive materials in particulate form with half-lives greater than 8 days.

(b)

The air dose per reactor to areas at and beyond the site boundary due to noble gases released in gaseous effluents shall be limited to:

During any calendar quarter, to less than or equal to 5 mrad for gamma radiation and less than or equal to 10 mrad for beta radiation.

During any calendar year, to less than or equal to 10 mrad for gamma radiation and less than or equal to 20 mrad for beta radiation.

(c)

The dose per reactor to a member of the public, due to I-131, I-133, H-3, Carbon-14 (C-14) and all radionuclides in particulate form with half-lives greater than 8 days in gaseous effluent released to areas at and beyond the site boundary shall not exceed 7.5 mrem to any organ during any Page 3 of 48

2022 -- Turkey Point Annual Radioactive Effluent Release Report calendar quarter and shall not exceed 15 mrem to any organ during any calendar year. C-14 dose was calculated using the guidance of Regulatory Guide 1.109, Calculations of Annual Doses to Man from Routine Releases of Reactor Effluents for the purpose of Evaluation Compliance with 10 CFR Part 50, Appendix I, Rev1, Oct 1977.

2.0 EFFLUENT CONCENTRATION Water : In accordance with 10 CFR 20, Appendix B, Table 2, Column 2, and for entrained or dissolved noble gases as described in 1.1 of this report.

Air : Release concentrations are limited to dose rate limits described in 1.2 cut this report.

3.0 AVERAGE ENERGY The average energy of fission and activation gases in effluents is not applicable.

4.0 MEASUREMENTS AND APPROXIMATIONS OF TOTAL ACTIVITY All liquid and airborne discharges to the environment during this period were analyzed in accordance with Technical Specification requirements as stated in the Offsite Dose Calculation Manual (ODCM). The minimum frequency of analysis as required by Regulatory Guide 1.21 was met or exceeded.

4.1 Liquid Effluents Aliquots of representative pre-release samples, from the waste disposal system, were isotopically analyzed for gamma-emitting isotopes on a multichannel analyzer.

Frequent periodic sampling and analysis were used to determine if radioactivity was being released via the steam generator blowdown system and the storm drain system. Environmental sampling is performed in accordance with the ODCM and corporate policy.

Monthly and quarterly composite samples for the waste disposal system were prepared to give proportional weight to each liquid release made during the designated period of accumulation. The monthly composite was analyzed for tritium and gross alpha radioactivity. Tritium was determined by use of liquid scintillation techniques, and gross alpha radioactivity was determined by use of a solid-state scintillation system. The quarterly composite was analyzed for strontium 89 (Sr-89), strontium 90 (Sr-90), nickel 63 (Ni-63), and iron 55 (Fe-55) by chemical separation. Canal Evaporation dose calculations were done in accordance with the ODCM Section 2.0 Radioactive Liquid Effluents (p. 2-35).

Page 4 of 48

2022 -- Turkey Point Annual Radioactive Effluent Release Report All radioactivity concentrations determined from sample analysis of a pre-release composite were multiplied by the total represented volume of the liquid waste released to determine the total quantity of each isotope and of gross alpha activity released during the compositing period.

Aliquots of representative samples from the waste disposal system were analyzed on a pre-release basis by gamma spectral analysis. The resulting isotope concentrations were multiplied by the total volume released in order to estimate the total dissolved gases released.

The liquid waste treatment system is shared by both units at the site and generally, all liquid releases are allocated on a 50/50 basis to each unit respectively.

4.2 Gaseous Effluents Airborne releases to the atmosphere occurred from the following sources:

- Gas Decay Tanks

- Containment Purges

- RWST via vent line

- U3 and U4 Equipment hatch during outages

- Releases incidental to operation of the plant

- Canal Evaporation Releases The techniques employed in determining the radioactivity in airborne releases are:

a) Gamma spectral analysis for fission and activation gases, b) Removal of particulate material by filtration and subsequent gamma spectral analysis, Sr-89, Sr-90 determination, and gross alpha determination, c) Absorption of halogen radionuclides on a charcoal filter and subsequent gamma spectral analysis.

d) Analysis of water vapor in a gas sample for tritium using liquid scintillation techniques.

e) C-14 curies were calculated using the guidance of Estimation of C-14 in Nuclear Power Plant Gaseous Effluents, TR 1021106, EPRI, Palo Alto, CA: 2010 Page 5 of 48 Both units share portions of the liquid and gaseous waste treatment system and generally, all treated waste from eacr reactor are allocated on 50/50 ratio.

Meterological data for the period January 2022 through december 2022, in the form Frequency Distribution Tables, are maintained on-site.

2022 -- Turkey Point Annual Radioactive Effluent Release Report 4.3 Estimation of Errors a) Sampling Error The error associated with volume measurement devices, flow measuring devices, etc., based on calibration data and design tolerances has been conservatively estimated to be collectively less than +/- 10%.

b) Analytical Error Our Q.C. Cross-Check Program involves counting unknown samples provided by an independent external lab. The errors associated with our analysis of these unknown samples, reported to us by the independent lab, were used as the basis for deriving the following analytical error terms:

ERROR NUCLIDE TYPE Liquid Gaseous 5.0 BATCH RELEASES

+/- 2.59%

+/- 3.31%

MAXIMUM ERROR

+/-7.52%

+/- 6.92%

See attached Open Effluent Management Software report.

6.0 UNPLANNED RELEASES 6.1 Liquid Release Occurrences AR (02433824): Unplanned Release; Water was observed flowing from an open valve, 3-713G, 3A CCW Heat Exchanger Vent. This corresponded with the lowering of the 3CCW Head Tank Level. The valve was closed isolating the vent flow by the SNPO after obtaining Control Room concurrence. U3 CCW was sampled 8/8/22 @ 0424 and indicated Na-24 at 1.76E-7 uCi/mL and a concentration of H-3 at 4.78E-5 uCi/mL. The water from 3-713G, 3A Heat Exchanger Vent, was not captured and allowed to flow to a floor drain which leads out to the North East Storm drain. Total curies from unplanned liquid release was conservtively 4.78E-11 curies. See table 6A.

Page 6 of 48

2022 -- Turkey Point Annual Radioactive Effluent Release Report 6.2 Gaseous Release Occurrences There were no unplanned gaseous release occurrences.

7.0 REACTOR COOLANT ACTIVITY 7.1 Unit 3 Reactor coolant activity limits of 0.25 µCi/gram Dose Equivalent I-131 and 447.7

µCi/gram Dose Equivalent Xenon (Xe-133) were not exceeded during this reporting period.

7.2 Unit 4 Reactor coolant activity limits of 0.25 µCi/gram Dose Equivalent I-131 and 447.7

µCi/gram Dose Equivalent Xe-133 were not exceeded during this reporting period.

8.0 SITE RADIATION DOSE The assessment of radiation dose from radioactive effluents to the general public due to their activities inside the site boundary assumes a visitor was at the child development center/fitness center for ten hours a day, five days each week for fifty weeks of the year, receiving exposure from both Unit 3 and Unit 4 at Turkey Point.

The child development center/fitness center is located approximately 1.75 miles WNW of the plant. Specific activities used in these calculations are the sum of the activities listed in the attached Unit 3 and Unit 4 Reg. Guide 1.21 tables. All dose to the public where a fraction of the limits and dose were maintained as low as reasonably achievable. The total calculated off-site dose to the public is summarized in the following Table A-5 per EPA 40 CFR 190 Individual in the Unrestricted Area.

Page 7 of 48

2022 -- Turkey Point Annual Radioactive Effluent Release Report 9.0 OFFSITE DOSE CALCULATION MANUAL (ODCM) REVISIONS The ODCM was revised in 2022 a complete copy is attached.

10.0 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS No irradiated fuel shipments or irradiated component shipments were made from the site. Common solid waste from Turkey Point Units 3 and 4 was shipped jointly. A summation of these shipments is given in Table 6 of this report.

11.0 PROCESS CONTROL PROGRAM REVISIONS There were no revisions to the Process Control Program during this reporting period.

12.0 INOPERABLE EFFLUENT MONITORING INSTRUMENTATION 01/05/22 (AR 02415299): R-3-19, Unit 3 Steam Generator Liquid Sample Monitor, failed on 12/06/21 at 1733. On 01/05/22, the monitor was declared out of service for more than 30 days.

09/27/22 (AR 02438074): U3 Spent Fuel Pool SPING ventilation was rendered non-functional after being shut down in accordance with 0-OP-060, Auxiliary Building HVAC section 6.1, Shutdown of Unit 3 Spent Fuel Pit Ventilation to support cable termination of RAD-3-6418 on 3-ONLINE 3-067-4DP88.

Design Change (EC 287982): Unit 3 Spent Fuel Pool SPING Rad Monitor Replacement Design Change (EC 280922): Plant Vent SPING Rad Monitor Replacement Design Change (EC 291559): U3 & U4 R-11/12 Rad Monitor Replacement 13.0 GROUND WATER SAMPLING In 2022 as part of the procedural requirements on Groundwater Protection Program, wells on site and adjacent to the site were sampled for tritium. The H-3 results were from less than MDA to 3980 picocuries per liter. Selected wells which met the criteria stipulated in the ODCM were analyzed for hard to detect beta emitters (Fe-59, Ni-63, Sr-89/90) and alpha. All results were less than the limits of the Offsite Dose Calculation Manual, Table 5.1-2, Reporting Levels for Radioactivity Concentrations in Environmental Samples. The results are reported in the Annual Radiological Environmental Operating Report.

Page 8 of 48 14.0 ERRATA DATA None.

2022 -- Turkey Point Annual Radioactive Effluent Release Report Unit 3 Reg. Guide 1.21 Tables:

1. Table A-1: Gaseous Effluents - Summation of all Releases-2.

Table A-1E: Gaseous Effluents - Mixed Mode Release - Batch Mode 3.

Table A-1F: Gaseous Effluents - Mixed Mode Release - Continuous Mode 4.

Table A-2: Liquid Effluents - Summation of all Releases 5.

Table A-2A: Liquid Effluents - Batch Mode 6.

Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Dose to a Member of the Public due to Liquid Release 7.

Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Air Dose Due to Gaseous Releases 8.

Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Dose due to Radioiodines, Tritium, and Particulates in Gaseous Releases

10. Table 5A and 5B: Liquid and Gas Batch Release Summary
11. Table 6A and 6B: Liquid and Gas Abnormal Release Summary Only tables that pertain to mixed mode release are included. Unit 3 does not have ground level or elevated releases therefore, tables A-1A, 1B, 1C, 1D are not included.

Page 9 of 48 9.

Table A-5. EPA 40 CFR Part 190 Individual in the Unrestricted Area

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report Table A-1, Gaseous Effluents - Summation of All Releases Unit: 3 January 2022 through December 2022 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases

1. Total Release Ci 1.17E-02 5.06E-03 0.00E+00 1.31E-03 1.81E-02
2. Average Release Rate for Period
3. Percent of Limit uCi/s 1.50E-03 6.43E-04 0.00E+00 1.65E-04 5.73E-04 B. Iodines and Halogens
1. Total Release Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
2. Average Release Rate for Period
3. Percent of Limit uCi/s 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 C. Particulates
1. Total Release Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
2. Average Release Rate for Period
3. Percent of Limit uCi/s 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 D. Tritium
1. Total Release Ci 5.22E-01 0.00E+00 8.87E-02 0.00E+00 6.11E-01
2. Average Release Rate for Period
3. Percent of Limit uCi/s 6.72E-02 0.00E+00 1.12E-02 0.00E+00 1.94E-02 E. Gross Alpha
1. Total Release F. Carbon-14 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
1. Total Release Ci 1.77E+00 1.81E+00 1.85E+00 1.85E+00 7.28E+00
2. Average Release Rate for Period
3. Percent of Limit uCi/s 2.28E-01 2.30E-01 2.33E-01 2.33E-01 2.31E-01 Page 10 of 48 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report Table A-1E, Gaseous Effluents - Mixed Mode Release - Batch Mode Unit: 3 January 2022 through December 2022 Batch Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases Ar-41 Ci 0.00E+00 2.73E-06 0.00E+00 0.00E+00 2.73E-06 Xe-131m Ci 4.32E-05 0.00E+00 0.00E+00 0.00E+00 4.32E-05 Xe-133m Ci 2.07E-04 0.00E+00 0.00E+00 0.00E+00 2.07E-04 Xe-133 Ci 1.14E-02 5.05E-03 0.00E+00 1.31E-03 1.78E-02 Xe-135 Ci 5.85E-05 3.44E-06 0.00E+00 0.00E+00 6.19E-05 Total For Period Ci 1.17E-02 5.06E-03 0.00E+00 1.31E-03 1.81E-02 B. Iodines and Halogens No Nuclides Found Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 C. Particulates No Nuclides Found Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 D. Tritium No Nuclides Found Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 E. Gross Alpha No Nuclides Found Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 F. Carbon-14 No Nuclides Found Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 If Not Detected, Nuclide is Not Required. Zeroes in this table indicates that no radioactivity was present at detectable levels.

Page 11 of 48

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report Table A-1F, Gaseous Effluents - Mixed Mode Release - Continuous Mode Unit: 3 January 2022 through December 2022 Continuous Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases No Nuclides Found B. Iodines and Halogens Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 No Nuclides Found C. Particulates Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 No Nuclides Found D. Tritium Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 H-3 Ci 5.22E-01 0.00E+00 8.87E-02 0.00E+00 6.11E-01 E. Gross Alpha No Nuclides Found F. Carbon-14 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 C-14 Ci 1.77E+00 1.81E+00 1.85E+00 1.85E+00 7.28E+00 If Not Detected, Nuclide is Not Required. Zeroes in this table indicates that no radioactivity was present at detectable levels.

Page 12 of 48

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report Table A-2, Liquid Effluents - Summation of All Releases Unit: 3 January 2022 through December 2022 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Products

1. Total Release Ci 9.43E-03 2.99E-02 6.53E-04 8.01E-05 4.01E-02
2. Average Concentration
3. Percent of Limit uCi/mL 7.76E-10 3.22E-09 2.26E-10 2.10E-11 1.43E-09 B. Tritium
1. Total Release Ci 2.06E+02 5.84E+01 1.78E+01 1.09E+02 3.91E+02
2. Average Concentration
3. Percent of Limit uCi/mL 1.69E-05 6.28E-06 6.15E-06 2.86E-05 1.39E-05 C. Dissolved and Entrained Gases
1. Total Release Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
2. Average Concentration
3. Percent of Limit uCi/mL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 D. Gross Alpha Activity
1. Total Release Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
2. Average Concentration uCi/mL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 E. Liquid Release Volume
1. Total Release Liters 7.27E+05 5.51E+05 1.60E+05 2.24E+05 1.66E+06 F. Dilution Volume
1. Total Release Liters 1.21E+10 9.30E+09 2.89E+09 3.81E+09 2.81E+10 G. Average Stream Flow
1. Total Release m^3/s 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Page 13 of 48 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report Table A-2A, Liquid Effluents - Batch Mode Unit: 3 January 2022 through December 2022 Batch Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Products Cr-51 Ci 2.50E-03 7.53E-04 0.00E+00 0.00E+00 3.25E-03 Mn-54 Ci 0.00E+00 8.41E-07 1.36E-06 0.00E+00 2.20E-06 Fe-55 Ci 2.17E-03 6.22E-04 0.00E+00 0.00E+00 2.79E-03 Fe-59 Ci 5.85E-04 3.88E-05 0.00E+00 0.00E+00 6.24E-04 Co-58 Ci 2.07E-03 2.86E-03 2.24E-04 6.66E-07 5.15E-03 Co-60 Ci 1.01E-04 6.55E-05 1.24E-05 0.00E+00 1.79E-04 Ni-63 Ci 4.83E-04 1.79E-02 1.15E-04 4.56E-05 1.85E-02 Zn-65 Ci 0.00E+00 2.44E-06 2.07E-06 0.00E+00 4.50E-06 Sr-89 Ci 0.00E+00 0.00E+00 1.86E-06 0.00E+00 1.86E-06 Sr-90 Ci 2.78E-06 1.11E-05 3.21E-07 1.79E-06 1.60E-05 Zr-95 Ci 3.50E-05 2.89E-06 0.00E+00 0.00E+00 3.79E-05 Nb-95 Ci 8.64E-05 0.00E+00 0.00E+00 0.00E+00 8.64E-05 Nb-97 Ci 2.76E-06 0.00E+00 0.00E+00 0.00E+00 2.76E-06 Ag-110m Ci 4.89E-05 1.03E-05 0.00E+00 0.00E+00 5.92E-05 Sn-113 Ci 9.69E-06 0.00E+00 0.00E+00 0.00E+00 9.69E-06 Sn-117m Ci 3.68E-05 5.73E-06 0.00E+00 0.00E+00 4.25E-05 Sb-122 Ci 5.92E-06 2.50E-06 0.00E+00 0.00E+00 8.42E-06 Sb-124 Ci 1.65E-04 9.68E-04 1.09E-05 0.00E+00 1.14E-03 Sb-125 Ci 6.68E-04 5.59E-03 2.79E-04 3.21E-05 6.57E-03 Te-129 Ci 3.06E-04 2.04E-04 0.00E+00 0.00E+00 5.10E-04 Te-132 Ci 3.95E-06 0.00E+00 0.00E+00 0.00E+00 3.95E-06 Cs-137 Ci 1.48E-04 9.05E-04 6.00E-06 0.00E+00 1.06E-03 Cs-138 Ci 0.00E+00 1.14E-05 0.00E+00 0.00E+00 1.14E-05 Total For Period Ci 9.43E-03 2.99E-02 6.53E-04 8.01E-05 4.01E-02 Page 14 of 48 If Not Detected, Nuclide is Not Required. Zeroes in this table indicates that no radioactivity was present at detectable levels.

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report Table A-2A, Liquid Effluents - Batch Mode Unit: 3 January 2022 through December 2022 Batch Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual B. Tritium H-3 Ci 2.06E+02 5.84E+01 1.78E+01 1.09E+02 3.91E+02 C. Dissolved and Entrained Gases No Nuclides Found D. Gross Alpha Activity Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 No Nuclides Found Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 If Not Detected, Nuclide is Not Required. Zeroes in this table indicates that no radioactivity was present at detectable levels.

Page 15 of 48

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report TABLE A-4: Dose Assessments 10 CFR Part 50, Appendix I Doses to a member of the public due to Liquid Releases Unit: 3 January 2022 through December 2022 Organ Dose Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Bone Limit Percent of Limit mRem mRem 1.24E-05 4.89E-05 2.05E-06 1.44E-07 6.35E-05 5.000 5.000 5.000 5.000 10.000 0.000 0.001 0.000 0.000 0.001 Liver Limit Percent of Limit mRem mRem 1.24E-05 4.89E-05 2.05E-06 1.44E-07 6.35E-05 5.000 5.000 5.000 5.000 10.000 0.000 0.001 0.000 0.000 0.001 Total Body Limit Percent of Limit mRem mRem 1.24E-05 4.89E-05 2.05E-06 1.44E-07 6.35E-05 1.500 1.500 1.500 1.500 3.000 0.001 0.003 0.000 0.000 0.002 Thyroid Limit Percent of Limit mRem mRem 1.24E-05 4.89E-05 2.05E-06 1.44E-07 6.35E-05 5.000 5.000 5.000 5.000 10.000 0.000 0.001 0.000 0.000 0.001 Kidney Limit Percent of Limit mRem mRem 1.24E-05 4.89E-05 2.05E-06 1.44E-07 6.35E-05 5.000 5.000 5.000 5.000 10.000 0.000 0.001 0.000 0.000 0.001 Lung Limit Percent of Limit mRem mRem 1.24E-05 4.89E-05 2.05E-06 1.44E-07 6.35E-05 5.000 5.000 5.000 5.000 10.000 0.000 0.001 0.000 0.000 0.001 GI-Lli Limit Percent of Limit mRem mRem 1.24E-05 4.89E-05 2.05E-06 1.44E-07 6.35E-05 5.000 5.000 5.000 5.000 10.000 0.000 0.001 0.000 0.000 0.001 Page 16 of 48

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report TABLE A-4: Dose Assessments 10 CFR Part 50, Appendix I Doses to a member of the public due to Liquid Releases Unit: 3 January 2022 through December 2022 Organ Dose Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Skin mRem 1.44E-05 5.61E-05 2.35E-06 1.62E-07 7.30E-05 Limit mRem 5.000 5.000 5.000 5.000 10.000 Percent of Limit 0.000 0.001 0.000 0.000 0.001 Page 17 of 48

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report TABLE A-4: Dose Assessments 10 CFR Part 50, Appendix I Air Doses Due To Gaseous Releases Unit: 3 January 2022 through December 2022 NG Dose Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Gamma Air Limit Percent of Limit mRad mRad 1.71E-07 7.36E-08 0.00E+00 1.88E-08 2.63E-07 Beta Air Limit Percent of Limit mRad mRad 5.10E-07 2.18E-07 0.00E+00 5.65E-08 7.84E-07 NG Total Body Limit Percent of Limit mRem mRem 1.44E-07 6.24E-08 0.00E+00 1.59E-08 2.23E-07 NG Skin Limit Percent of Limit mRem mRem 3.47E-07 1.46E-07 0.00E+00 3.75E-08 5.31E-07 Page 18 of 48

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report TABLE A-4: Dose Assessments 10 CFR Part 50, Appendix I Doses due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: 3 January 2022 through December 2022 Organ Dose Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Bone Limit Percent of Limit mRem mRem 2.51E-02 2.57E-02 2.62E-02 2.62E-02 1.03E-01 7.500 7.500 7.500 7.500 15.000 0.334 0.342 0.349 0.349 0.688 Liver Limit Percent of Limit mRem mRem 2.51E-02 2.56E-02 2.62E-02 2.62E-02 1.03E-01 7.500 7.500 7.500 7.500 15.000 0.335 0.342 0.349 0.349 0.688 Total Body Limit Percent of Limit mRem mRem 2.51E-02 2.56E-02 2.62E-02 2.62E-02 1.03E-01 Thyroid Limit Percent of Limit mRem mRem 2.51E-02 2.56E-02 2.62E-02 2.62E-02 1.03E-01 7.500 7.500 7.500 7.500 15.000 0.335 0.342 0.349 0.349 0.688 Kidney Limit Percent of Limit mRem mRem 4.74E-03 4.82E-03 4.93E-03 4.92E-03 1.94E-02 7.500 7.500 7.500 7.500 15.000 0.063 0.064 0.066 0.066 0.129 Lung Limit Percent of Limit mRem mRem 2.51E-02 2.56E-02 2.62E-02 2.62E-02 1.03E-01 7.500 7.500 7.500 7.500 15.000 0.335 0.342 0.349 0.349 0.688 GI-Lli Limit Percent of Limit mRem mRem 2.51E-02 2.56E-02 2.62E-02 2.62E-02 1.03E-01 7.500 7.500 7.500 7.500 15.000 0.335 0.342 0.349 0.349 0.688 Page 19 of 48

2022 -- Turkey Point Annual Radioactive Effluent Release Report Table A-5. EPA 40 CFR Part 190 Individual in the Unrestricted Area Total Dose Visitor Dose Limit Total Dose Visitor Dose (mrem)

(mrem)

(mrem)

Percent of Limit (%)

Percent of Limit (%)

Bone (mrem) 1.97E-01 1.68E-01 25 7.88E-01 6.72E-01 Liver (mrem) 1.97E-01 1.68E-01 25 7.88E-01 6.72E-01 Thyroid (mrem) 1.97E-01 1.68E-01 75 2.63E-01 2.24E-01 Kidney (mrem) 3.70E-02 3.16E-02 25 1.48E-01 1.26E-01 Lung (mrem) 1.97E-01 1.68E-01 25 7.88E-01 6.72E-01 GI-LLI (mrem) 1.97E-01 1.68E-01 25 7.88E-01 6.72E-01 Skin (mrem) 3.09E-06 2.64E-06 25 1.24E-05 1.05E-05 Total Body (mrem) 1.97E-01 1.68E-01 25 7.88E-01 6.72E-01 Gamma Air Dose (mrad) 5.26E-07 8.89E-08 10 5.26E-06 8.89E-07 Beta Air Dose (mrad) 1.57E-07 2.65E-07 20 7.85E-07 1.33E-06 Noble Gas Total Body Air Dose (mrad) 4.46E-07 7.54E-08 500 8.92E-08 1.51E-08 Noble Gas Skin Air Dose (mrad) 1.06E-06 1.79E-07 3000 3.53E-08 5.97E-09 Page 20 of 48

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Report Table 5A and 5B - Liquid and Gas Batch Release Summary Unit: 3 January 2022 through December 2022 A. Liquid Batch Release Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Year Totals

1. Number of Batch Releases 57 45 13 17 132
2. Total duration of batch releases min 5.42E+03 4.17E+03 1.22E+03 1.72E+03 1.25E+04
3. Maximum batch release duration min 1.10E+02 1.20E+02 1.10E+02 1.20E+02 1.20E+02
4. Average batch release duration min 9.52E+01 9.26E+01 9.40E+01 1.01E+02 9.50E+01
5. Minimum batch release duration min 5.00E+01 6.00E+01 7.30E+01 8.50E+01 5.00E+01 B. Gas Batch Release Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Year Totals
1. Number of Batch Releases 2

20 1

3 26

2. Total duration of batch releases min 5.70E+01 6.65E+02 1.70E+01 8.60E+01 8.25E+02
3. Maximum batch release duration min 3.20E+01 6.00E+01 1.70E+01 4.00E+01 6.00E+01
4. Average batch release duration min 2.85E+01 3.33E+01 1.70E+01 2.87E+01 3.17E+01
5. Minimum batch release duration min 2.50E+01 2.50E+01 1.70E+01 2.00E+01 1.70E+01 Page 21 of 48

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Report Table 6A and 6B - Liquid and Gas Abnormal Release Summary Unit: 3 January 2022 through December 2022 A. Liquid Abnormal Release Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Year Totals

1. Number of Abnormal Releases 0

0 1

0 1

2. Total Activity of abnormal releases Ci 0.00E+00 0.00E+00 4.78E-11 0.00E+00 4.78E-11 B. Gas Abnormal Release Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Year Totals
1. Number of Abnormal Releases 0

0 0

0 0

2. Total Activity of abnormal releases Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Page 22 of 48

2022 -- Turkey Point Annual Radioactive Effluent Release Report Unit 4 Reg. Guide 1.21 Tables:

1. Table A-1: Gaseous Effluents - Summation of all Releases
2. Table A-1E: Gaseous Effluents - Mixed Mode Release - Batch Mode
3. Table A-1F: Gaseous Effluents - Mixed Mode Release - Continuous Mode
4. Table A-2: Liquid Effluents - Summation of all Releases
5. Table A-2A: Liquid Effluents - Batch Mode
6. Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Dose to a member of the public due to Liquid Release
7. Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Air Dose Due to Gaseous Releases
8. Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Dose due to Radioiodines, Tritium, and Particulates in Gaseous Releases
9. Liquid and Gas Batch Release Summary
10. Table 6: Liquid and Gas Abnormal Release Summary Only tables that pertain to mixed mode release are included. Unit 4 does not have ground level or elevated releases therefore, tables A-1A, 1B, 1C, 1D are not included.

Page 23 of 48

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report Table A-1, Gaseous Effluents - Summation of All Releases Unit: 4 January 2022 through December 2022 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases

1. Total Release Ci 1.17E-02 5.06E-03 0.00E+00 1.31E-03 1.81E-02
2. Average Release Rate for Period
3. Percent of Limit uCi/s 1.50E-03 6.43E-04 0.00E+00 1.65E-04 5.73E-04 B. Iodines and Halogens
1. Total Release Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
2. Average Release Rate for Period
3. Percent of Limit uCi/s 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 C. Particulates
1. Total Release Ci 9.41E-06 1.94E-05 0.00E+00 0.00E+00 2.88E-05
2. Average Release Rate for Period
3. Percent of Limit uCi/s 1.21E-06 2.47E-06 0.00E+00 0.00E+00 9.13E-07 D. Tritium
1. Total Release Ci 4.20E-01 0.00E+00 0.00E+00 0.00E+00 4.20E-01
2. Average Release Rate for Period
3. Percent of Limit uCi/s 5.40E-02 0.00E+00 0.00E+00 0.00E+00 1.33E-02 E. Gross Alpha
1. Total Release F. Carbon-14 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
1. Total Release Ci 1.37E+00 1.57E+00 1.85E+00 1.81E+00 6.59E+00
2. Average Release Rate for Period
3. Percent of Limit uCi/s 1.76E-01 2.00E-01 2.33E-01 2.28E-01 2.09E-01 Page 24 of 48 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report Table A-1E, Gaseous Effluents - Mixed Mode Release - Batch Mode Unit: 4 January 2022 through December 2022 Batch Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases Ar-41 Ci 0.00E+00 2.73E-06 0.00E+00 0.00E+00 2.73E-06 Xe-131m Ci 4.32E-05 0.00E+00 0.00E+00 0.00E+00 4.32E-05 Xe-133m Ci 2.07E-04 0.00E+00 0.00E+00 0.00E+00 2.07E-04 Xe-133 Ci 1.14E-02 5.05E-03 0.00E+00 1.31E-03 1.78E-02 Xe-135 Ci 5.85E-05 3.44E-06 0.00E+00 0.00E+00 6.19E-05 Total For Period Ci 1.17E-02 5.06E-03 0.00E+00 1.31E-03 1.81E-02 B. Iodines and Halogens No Nuclides Found Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 C. Particulates Co-58 Ci 8.73E-06 7.34E-06 0.00E+00 0.00E+00 1.61E-05 Co-60 Ci 4.47E-07 5.42E-07 0.00E+00 0.00E+00 9.90E-07 Zr-95 Ci 0.00E+00 4.95E-06 0.00E+00 0.00E+00 4.95E-06 Nb-95 Ci 2.35E-07 6.55E-06 0.00E+00 0.00E+00 6.78E-06 Total For Period Ci 9.41E-06 1.94E-05 0.00E+00 0.00E+00 2.88E-05 D. Tritium H-3 Ci 1.28E-01 0.00E+00 0.00E+00 0.00E+00 1.28E-01 E. Gross Alpha No Nuclides Found Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 F. Carbon-14 No Nuclides Found Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 If Not Detected, Nuclide is Not Required. Zeroes in this table indicates that no radioactivity was present at detectable levels.

Page 25 of 48

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report Table A-1F, Gaseous Effluents - Mixed Mode Release - Continuous Mode Unit: 4 January 2022 through December 2022 Continuous Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases No Nuclides Found B. Iodines and Halogens Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 No Nuclides Found C. Particulates Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 No Nuclides Found D. Tritium Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 H-3 Ci 2.92E-01 0.00E+00 0.00E+00 0.00E+00 2.92E-01 E. Gross Alpha No Nuclides Found F. Carbon-14 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 C-14 Ci 1.37E+00 1.57E+00 1.85E+00 1.81E+00 6.59E+00 If Not Detected, Nuclide is Not Required. Zeroes in this table indicates that no radioactivity was present at detectable levels.

Page 26 of 48

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report Table A-2, Liquid Effluents - Summation of All Releases Unit: 4 January 2022 through December 2022 Total Release Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Products

1. Total Release Ci 9.43E-03 2.99E-02 6.53E-04 8.01E-05 4.01E-02
2. Average Concentration
3. Percent of Limit uCi/mL 7.76E-10 3.22E-09 2.26E-10 2.10E-11 1.43E-09 B. Tritium
1. Total Release Ci 2.06E+02 5.84E+01 1.78E+01 1.09E+02 3.91E+02
2. Average Concentration
3. Percent of Limit uCi/mL 1.69E-05 6.28E-06 6.15E-06 2.86E-05 1.39E-05 C. Dissolved and Entrained Gases
1. Total Release Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
2. Average Concentration
3. Percent of Limit uCi/mL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 D. Gross Alpha Activity
1. Total Release Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00
2. Average Concentration uCi/mL 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 E. Liquid Release Volume
1. Total Release Liters 7.27E+05 5.51E+05 1.60E+05 2.24E+05 1.66E+06 F. Dilution Volume
1. Total Release Liters 1.21E+10 9.30E+09 2.89E+09 3.81E+09 2.81E+10 G. Average Stream Flow
1. Total Release m^3/s 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Page 27 of 48 N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report Table A-2A, Liquid Effluents - Batch Mode Unit: 4 January 2022 through December 2022 Batch Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Products Cr-51 Ci 2.50E-03 7.53E-04 0.00E+00 0.00E+00 3.25E-03 Mn-54 Ci 0.00E+00 8.41E-07 1.36E-06 0.00E+00 2.20E-06 Fe-55 Ci 2.17E-03 6.22E-04 0.00E+00 0.00E+00 2.79E-03 Fe-59 Ci 5.85E-04 3.88E-05 0.00E+00 0.00E+00 6.24E-04 Co-58 Ci 2.07E-03 2.86E-03 2.24E-04 6.66E-07 5.15E-03 Co-60 Ci 1.01E-04 6.55E-05 1.24E-05 0.00E+00 1.79E-04 Ni-63 Ci 4.83E-04 1.79E-02 1.15E-04 4.56E-05 1.85E-02 Zn-65 Ci 0.00E+00 2.44E-06 2.07E-06 0.00E+00 4.50E-06 Sr-89 Ci 0.00E+00 0.00E+00 1.86E-06 0.00E+00 1.86E-06 Sr-90 Ci 2.78E-06 1.11E-05 3.21E-07 1.79E-06 1.60E-05 Zr-95 Ci 3.50E-05 2.89E-06 0.00E+00 0.00E+00 3.79E-05 Nb-95 Ci 8.64E-05 0.00E+00 0.00E+00 0.00E+00 8.64E-05 Nb-97 Ci 2.76E-06 0.00E+00 0.00E+00 0.00E+00 2.76E-06 Ag-110m Ci 4.89E-05 1.03E-05 0.00E+00 0.00E+00 5.92E-05 Sn-113 Ci 9.69E-06 0.00E+00 0.00E+00 0.00E+00 9.69E-06 Sn-117m Ci 3.68E-05 5.73E-06 0.00E+00 0.00E+00 4.25E-05 Sb-122 Ci 5.92E-06 2.50E-06 0.00E+00 0.00E+00 8.42E-06 Sb-124 Ci 1.65E-04 9.68E-04 1.09E-05 0.00E+00 1.14E-03 Sb-125 Ci 6.68E-04 5.59E-03 2.79E-04 3.21E-05 6.57E-03 Te-129 Ci 3.06E-04 2.04E-04 0.00E+00 0.00E+00 5.10E-04 Te-132 Ci 3.95E-06 0.00E+00 0.00E+00 0.00E+00 3.95E-06 Cs-137 Ci 1.48E-04 9.05E-04 6.00E-06 0.00E+00 1.06E-03 Cs-138 Ci 0.00E+00 1.14E-05 0.00E+00 0.00E+00 1.14E-05 Total For Period Ci 9.43E-03 2.99E-02 6.53E-04 8.01E-05 4.01E-02 Page 28 of 48 If Not Detected, Nuclide is Not Required. Zeroes in this table indicates that no radioactivity was present at detectable levels.

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report Table A-2A, Liquid Effluents - Batch Mode Unit: 4 January 2022 through December 2022 Batch Mode Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual B. Tritium H-3 Ci 2.06E+02 5.84E+01 1.78E+01 1.09E+02 3.91E+02 C. Dissolved and Entrained Gases No Nuclides Found D. Gross Alpha Activity Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 No Nuclides Found Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 If Not Detected, Nuclide is Not Required. Zeroes in this table indicates that no radioactivity was present at detectable levels.

Page 29 of 48

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report TABLE A-4: Dose Assessments 10 CFR Part 50, Appendix I Doses to a member of the public due to Liquid Releases Unit: 4 January 2022 through December 2022 Organ Dose Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Bone Limit Percent of Limit mRem mRem 1.24E-05 4.89E-05 2.05E-06 1.44E-07 6.35E-05 5.000 5.000 5.000 5.000 10.000 0.000 0.001 0.000 0.000 0.001 Liver Limit Percent of Limit mRem mRem 1.24E-05 4.89E-05 2.05E-06 1.44E-07 6.35E-05 5.000 5.000 5.000 5.000 10.000 0.000 0.001 0.000 0.000 0.001 Total Body Limit Percent of Limit mRem mRem 1.24E-05 4.89E-05 2.05E-06 1.44E-07 6.35E-05 1.500 1.500 1.500 1.500 3.000 0.001 0.003 0.000 0.000 0.002 Thyroid Limit Percent of Limit mRem mRem 1.24E-05 4.89E-05 2.05E-06 1.44E-07 6.35E-05 5.000 5.000 5.000 5.000 10.000 0.000 0.001 0.000 0.000 0.001 Kidney Limit Percent of Limit mRem mRem 1.24E-05 4.89E-05 2.05E-06 1.44E-07 6.35E-05 5.000 5.000 5.000 5.000 10.000 0.000 0.001 0.000 0.000 0.001 Lung Limit Percent of Limit mRem mRem 1.24E-05 4.89E-05 2.05E-06 1.44E-07 6.35E-05 5.000 5.000 5.000 5.000 10.000 0.000 0.001 0.000 0.000 0.001 GI-Lli Limit Percent of Limit mRem mRem 1.24E-05 4.89E-05 2.05E-06 1.44E-07 6.35E-05 5.000 5.000 5.000 5.000 10.000 0.000 0.001 0.000 0.000 0.001 Page 30 of 48

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report TABLE A-4: Dose Assessments 10 CFR Part 50, Appendix I Doses to a member of the public due to Liquid Releases Unit: 4 January 2022 through December 2022 Organ Dose Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Skin mRem 1.44E-05 5.61E-05 2.35E-06 1.62E-07 7.30E-05 Limit mRem 5.000 5.000 5.000 5.000 10.000 Percent of Limit 0.000 0.001 0.000 0.000 0.001 Page 31 of 48

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report TABLE A-4: Dose Assessments 10 CFR Part 50, Appendix I Air Doses Due To Gaseous Releases Unit: 4 January 2022 through December 2022 NG Dose Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Gamma Air Limit Percent of Limit mRad mRad 1.71E-07 7.36E-08 0.00E+00 1.88E-08 2.63E-07 Beta Air Limit Percent of Limit mRad mRad 5.10E-07 2.18E-07 0.00E+00 5.65E-08 7.84E-07 NG Total Body Limit Percent of Limit mRem mRem 1.44E-07 6.24E-08 0.00E+00 1.59E-08 2.23E-07 NG Skin Limit Percent of Limit mRem mRem 3.47E-07 1.46E-07 0.00E+00 3.75E-08 5.31E-07 Page 32 of 48

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report TABLE A-4: Dose Assessments 10 CFR Part 50, Appendix I Doses due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: 4 January 2022 through December 2022 Organ Dose Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Bone Limit Percent of Limit mRem mRem 1.94E-02 2.22E-02 2.62E-02 2.56E-02 9.35E-02 7.500 7.500 7.500 7.500 15.000 0.259 0.297 0.349 0.342 0.623 Liver Limit Percent of Limit mRem mRem 1.94E-02 2.22E-02 2.62E-02 2.56E-02 9.35E-02 7.500 7.500 7.500 7.500 15.000 0.259 0.296 0.349 0.342 0.623 Total Body Limit Percent of Limit mRem mRem 1.94E-02 2.22E-02 2.62E-02 2.56E-02 9.35E-02 Thyroid Limit Percent of Limit mRem mRem 1.94E-02 2.22E-02 2.62E-02 2.56E-02 9.35E-02 7.500 7.500 7.500 7.500 15.000 0.259 0.296 0.349 0.342 0.623 Kidney Limit Percent of Limit mRem mRem 3.67E-03 4.18E-03 4.92E-03 4.82E-03 1.76E-02 7.500 7.500 7.500 7.500 15.000 0.049 0.056 0.066 0.064 0.117 Lung Limit Percent of Limit mRem mRem 1.94E-02 2.22E-02 2.62E-02 2.56E-02 9.35E-02 7.500 7.500 7.500 7.500 15.000 0.259 0.296 0.349 0.342 0.623 GI-Lli Limit Percent of Limit mRem mRem 1.94E-02 2.22E-02 2.62E-02 2.56E-02 9.35E-02 7.500 7.500 7.500 7.500 15.000 0.259 0.296 0.349 0.342 0.623 Page 33 of 48

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Release Report TABLE A-4: Dose Assessments 10 CFR Part 50, Appendix I Doses due to Radioiodines, Tritium, and Particulates in Gaseous Releases Unit: 4 January 2022 through December 2022 Organ Dose Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Skin mRem 1.30E-06 1.79E-06 0.00E+00 0.00E+00 3.09E-06 Limit mRem 7.500 7.500 7.500 7.500 15.000 Percent of Limit 0.000 0.000 0.000 0.000 0.000 Page 34 of 48

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Report Table 5A and 5B - Liquid and Gas Batch Release Summary Unit: 4 January 2022 through December 2022 A. Liquid Batch Release Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Year Totals

1. Number of Batch Releases 57 45 13 17 132
2. Total duration of batch releases min 5.42E+03 4.17E+03 1.22E+03 1.72E+03 1.25E+04
3. Maximum batch release duration min 1.10E+02 1.20E+02 1.10E+02 1.20E+02 1.20E+02
4. Average batch release duration min 9.52E+01 9.26E+01 9.40E+01 1.01E+02 9.50E+01
5. Minimum batch release duration min 5.00E+01 6.00E+01 7.30E+01 8.50E+01 5.00E+01 B. Gas Batch Release Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Year Totals
1. Number of Batch Releases 20 32 1

3 56

2. Total duration of batch releases min 2.19E+04 7.50E+03 1.70E+01 8.60E+01 2.95E+04
3. Maximum batch release duration min 1.30E+04 1.04E+03 1.70E+01 4.00E+01 1.30E+04
4. Average batch release duration min 1.09E+03 2.34E+02 1.70E+01 2.87E+01 5.27E+02
5. Minimum batch release duration min 2.50E+01 2.50E+01 1.70E+01 2.00E+01 1.70E+01 Page 35 of 48

Florida Power & Light Co., Turkey Point Nuclear Annual Radioactive Effluent Report Table 6A and 6B - Liquid and Gas Abnormal Release Summary Unit: 4 January 2022 through December 2022 A. Liquid Abnormal Release Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Year Totals

1. Number of Abnormal Releases 0

0 0

0 0

2. Total Activity of abnormal releases Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 B. Gas Abnormal Release Totals Units 1st Quarter 2nd Quarter 3rd Quarter 4th Quarter Year Totals
1. Number of Abnormal Releases 0

0 0

0 0

2. Total Activity of abnormal releases Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Page 36 of 48

2022 -- Turkey Point Annual Radioactive Effluent Release Report Site Dose Reg. Guide 1.21 Tables:

Canal Reuse/Return tritium Only tables that pertain to site ground mode release are included. Unit 3 and Unit 4 combine their effluent to the canal system. The tables for continuous release from evaporation from the canal are considered ground releases are included.

1. Table A-1B: Gaseous Effluents - Ground Level Release --Return - Continuous Mode
2. Table A-4: Dose Assessments 10 CFR Part 50, Appendix I: Dose due to Radioiodines, Tritium, and Particulates in Gaseous Releases Page 37 of 48

2022 -- Turkey Point Annual Radioactive Effluent Release Report Reg. Guide 1.21, Table A-1B, Gaseous Effluents - Canal Return/Re-Use Ground Level Continuous Mode Unit: Site January-2022 thru December-2022 Nuclides Released Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual A. Fission and Activation Gases No Nuclides Found B. Iodines and Halogens Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 No Nuclides Found C. Particulates Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 No Nuclides Found D. Tritium Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 H-3 E. Gross Alpha Ci 6.09E+01 1.04E+02 2.34E+01 1.41E+01 2.03E+02 No Nuclides Found F. Carbon-14 Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 No Nuclides Found Ci 0.00E+00 0.00E+00 0.00E+00 0.00E+00 0.00E+00 Page 38 of 48

2022 -- Turkey Point Annual Radioactive Effluent Release Report TABLE A-4: Dose Assessments 10 CFR Part 50, Appendix I Doses due to Tritium Return From Closed Cooling Canal Evaporation Unit: Site January 2022 through December 2022 Organ Dose Units 1ST Quarter 2ND Quarter 3RD Quarter 4TH Quarter Annual Liver mRem 3.22E-03 5.51E-03 1.24E-03 7.45E-04 1.07E-02 Limit mRem 5

5 5

5 10 Percent of Limit 6.44E-02 1.10E-01 2.50E-02 1.50E-02 1.07E-01 Thyroid mRem 3.22E-03 5.51E-03 1.24E-03 7.45E-04 1.07E-02 Limit mRem 5

5 5

5 10 Percent of Limit 6.44E-02 1.10E-01 2.50E-02 1.50E-02 1.07E-01 Kidney mRem 3.22E-03 5.51E-03 1.24E-03 7.45E-04 1.07E-02 Limit mRem 5

5 5

5 10 Percent of Limit 6.44E-02 1.10E-01 2.50E-02 1.50E-02 1.07E-01 Lung mRem 3.22E-03 5.51E-03 1.24E-03 7.45E-04 1.07E-02 Limit mRem 5

5 5

5 10 Percent of Limit 6.44E-02 1.10E-01 2.50E-02 1.50E-02 1.07E-01 Gi-LLI mRem 3.22E-03 5.51E-03 1.24E-03 7.45E-04 1.07E-02 Limit mRem 5

5 5

5 10 Percent of Limit 6.44E-02 1.10E-01 2.50E-02 1.50E-02 1.07E-01 Page 39 of 48

2022 -- Turkey Point Annual Radioactive Effluent Release Report TABLE 6 SOLID WASTE AND IRRADIATED FUEL SHIPMENTS Page 40 of 48

WMG Suite 9.5.4 Reg Guide Activity Report Report Date: 01/31/2023 NRC Regulatory Guide 1.21 Activity Report Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Shipment, Package, and Category During Period From: 01/01/2022 to 12/31/2022 Percent Cutoff: 1.0%

Dry Active Waste Waste Class A Nuclide Name Abundance Activity (Ci)

Fe-55 47.83%

4.11E-01 Co-58 4.47%

3.84E-02 Co-60 9.43%

8.10E-02 Ni-63 33.21%

2.85E-01 Nb-95 1.13%

9.72E-03 Sb-125 1.02%

8.80E-03 Total Combined Nuclide Name Abundance Activity (Ci)

Fe-55 47.83%

4.11E-01 Co-58 4.47%

3.84E-02 Co-60 9.43%

8.10E-02 Ni-63 33.21%

2.85E-01 Nb-95 1.13%

9.72E-03 Sb-125 1.02%

8.80E-03 Other Waste Waste Class A Nuclide Name Abundance Activity (Ci)

Fe-55 54.96%

1.92E-02 Co-58 6.06%

2.11E-03 Co-60 10.59%

3.70E-03 Ni-63 24.83%

8.67E-03 Total Combined Nuclide Name Abundance Activity (Ci)

Fe-55 54.96%

1.92E-02 Co-58 6.06%

2.11E-03 Co-60 10.59%

3.70E-03 Ni-63 24.83%

8.67E-03 Sum of All 4 Categories Waste Class A Nuclide Name Abundance Activity (Ci)

Fe-55 48.1%

4.30E-01 Page 41 of 48

WMG Suite 9.5.4 Reg Guide Activity Report Report Date: 01/31/2023 NRC Regulatory Guide 1.21 Activity Report Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Shipment, Package, and Category During Period From: 01/01/2022 to 12/31/2022 Percent Cutoff: 1.0%

Co-58 4.53%

4.05E-02 Co-60 9.47%

8.47E-02 Ni-63 32.88%

2.94E-01 Nb-95 1.12%

1.00E-02 Sb-125 1.01%

9.00E-03 Total Combined Nuclide Name Abundance Activity (Ci)

Fe-55 48.1%

4.30E-01 Co-58 4.53%

4.05E-02 Co-60 9.47%

8.47E-02 Ni-63 32.88%

2.94E-01 Nb-95 1.12%

1.00E-02 Sb-125 1.01%

9.00E-03 Page 42 of 48

WMG Suite 9.5.4 Reg Guide Report Report Date: 01/31/2023 NRC Regulatory Guide 1.21 Report Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From: 01/01/2022 to 12/31/2022 Resins, Filters, And Evaporator Bottoms Waste Class Volume ft³ m³ Curies Shipped A

0.00E+00 0.00E+00 0.00E+00 B

0.00E+00 0.00E+00 0.00E+00 C

0.00E+00 0.00E+00 0.00E+00 Unclassified 0.00E+00 0.00E+00 0.00E+00 All 0.00E+00 0.00E+00 0.00E+00 Major Nuclides for the Above Table:

Dry Active Waste (DAW)

Waste Volume Curies Class ft³ m³ Shipped A

1.33E+04 3.76E+02 8.59E-01 B

0.00E+00 0.00E+00 0.00E+00 C

0.00E+00 0.00E+00 0.00E+00 Unclassified 0.00E+00 0.00E+00 0.00E+00 All 1.33E+04 3.76E+02 8.59E-01 Major Nuclides for the Above Table:

H-3, C-14, Mn-54, Fe-55, Co-58, Co-60, Ni-59, Ni-63, Sr-90, Zr-95, Nb-94, Nb-95, Tc-99, Ag-110m, Sb-125, I-129, Cs-137, Pu-238, Pu-239, Pu-241, Am-241, Cm-242, Cm-243 Irradiated Components Waste Volume Curies Class ft³ m³ Shipped A

0.00E+00 0.00E+00 0.00E+00 B

0.00E+00 0.00E+00 0.00E+00 C

0.00E+00 0.00E+00 0.00E+00 Unclassified 0.00E+00 0.00E+00 0.00E+00 All 0.00E+00 0.00E+00 0.00E+00 Major Nuclides for the Above Table:

Other Waste Waste Class Volume ft³ m³ Curies Shipped A

3.50E+03 9.92E+01 3.49E-02 B

0.00E+00 0.00E+00 0.00E+00 Page 43 of 48

WMG Suite 9.5.4 Reg Guide Report Report Date: 01/31/2023 NRC Regulatory Guide 1.21 Report Solid Waste Shipped Offsite for Disposal and Estimates of Major Nuclides by Waste Class and Stream During Period From: 01/01/2022 to 12/31/2022 Sum Of All Low-Level Waste Shipped From Site Waste Class Volume ft³ m³ Curies Shipped A

1.68E+04 4.75E+02 8.94E-01 B

0.00E+00 0.00E+00 0.00E+00 C

0.00E+00 0.00E+00 0.00E+00 Unclassified 0.00E+00 0.00E+00 0.00E+00 All 1.68E+04 4.75E+02 8.94E-01 Major Nuclides for the Above Table:

H-3, C-14, Mn-54, Fe-55, Co-58, Co-60, Ni-59, Ni-63, Sr-90, Zr-95, Nb-94, Nb-95, Tc-99, Ag-110m, Sb-125, I-129, Cs-137, Pu-238, Pu-239, Pu-241, Am-241, Cm-242, Cm-243 Page 44 of 48 C

0.00E+00 0.00E+00 0.00E+00 Unclassified 0.00E+00 0.00E+00 0.00E+00 All 3.50E+03 9.92E+01 3.49E-02 Major Nuclides for the Above Table:

H-3, C-14, Fe-55, Co-58, Co-60, Ni-59, Ni-63, Sr-90, Nb-94, Nb-95, Tc-99, I-129, Cs-137, Pu-238, Pu-239, Pu-241, Am-241, Cm-242, Cm-243

WMG Suite 9.5.4 Report date: 1/31/2023 NRC Regulatory Guide 1.21 Report Shipment and Package Summary Solid Waste Shipped Offsite for Disposal During Period from: 1/1/2022 to 12/31/2022 Shipment Date Manifest ID Destination Package Name Category Name NRC Class DOT Type 3/3/2022 PTN-W-22-001 Energy Solutions Gallaher Road Facility ESUU101067 Dry Active Waste A

Limited Quantity 3/3/2022 PTN-W-22-002 Energy Solutions Gallaher Road Facility ESUU200889 Dry Active Waste A

Limited Quantity ESUU202021 Dry Active Waste A

Limited Quantity 3/30/2022 0847-05-0001 EnergySolutions LLC.

ESUU200644 Dry Active Waste A

A LSA-II 3/30/2022 0847-04-0004 EnergySolutions LLC.

ESUU200980 Dry Active Waste A

A LSA-II 4/18/2022 PTN-W-22-005 Energy Solutions Bear Creek Road Fac.

ESUU200819 Dry Active Waste A

A LSA-II ESUU200556 Dry Active Waste A

A LSA-II 4/21/2022 PTN-W-22-006 Energy Solutions Bear Creek Road Fac.

ESUU200425 Dry Active Waste A

A LSA-II ESUU200845 Dry Active Waste A

A LSA-II 4/27/2022 PTN-W-22-007 Energy Solutions Bear Creek Road Fac.

ESUU200829 Dry Active Waste A

A LSA-II ESUU200499 Dry Active Waste A

A LSA-II 5/6/2022 PTN-W-22-008 Energy Solutions Gallaher Road Facility ESUU100362 Dry Active Waste A

Limited Quantity 8/18/2022 PTN-W-22-009 Energy Solutions Gallaher Road Facility PTNOIL-1 Other Waste A

A LSA-II ESUU200378 Dry Active Waste A

A LSA-II 10/13/2022 PTN-W-22-010 Energy Solutions Bear Creek Road Fac.

ESUU200943 Dry Active Waste A

Limited Quantity ESUU200704 Dry Active Waste A

Limited Quantity Page 45 of 48

WMG Suite 9.5.4 Report date: 1/31/2023 NRC Regulatory Guide 1.21 Report Shipment and Package Summary Solid Waste Shipped Offsite for Disposal During Period from: 1/1/2022 to 12/31/2022 11/2/2022 PTN-W-22-012 Energy Solutions Gallaher Road Facility ESUU100720 Other Waste A

Limited Quantity 11/2/2022 PTN-W-22-011 Energy Solutions Gallaher Road Facility ESUU200354 Other Waste A

Limited Quantity ESUU200686 Other Waste A

Limited Quantity 12/5/2022 PTN-W-22-013 Energy Solutions Bear Creek Road Fac.

ESUU200827 Dry Active Waste A

Limited Quantity ESUU300167A Dry Active Waste A

Limited Quantity Page 46 of 48

WMG Suite 9.5.4 Reg Guide Report Report Date: 01/31/2023 During Period From: 01/01/2022 to 12/31/2022 Total Shipments by Carrier Number of Shipments per each carrier Number of Shipments Mode of Transportation Destination 5

Hittman Transport Energy Solutions Bear Creek Road Fac.

1560 Bear Creek Road 5

Hittman Transport Energy Solutions Gallaher Road Facility 628 Gallaher Road 2

Hittman Transport EnergySolutions LLC.

Clive Disposal Site - Bulk Waste Facility 1

Landstar Energy Solutions Gallaher Road Facility 628 Gallaher Road Page 47 of 48

THIS PAGE INTENTIONALLY LEFT BLANK Page 48 of 48