Text
OFFICIAL USE ONLY - SENSITIVE UNCLASSIFIED INFORMATION OFFICIAL USE ONLY - SENSITIVE UNCLASSIFIED INFORMATION Wyatt Padgett Licensing and Performance Assessment Manager Louisiana Energy Services, LLC P.O. Box 1789 Eunice, NM 88231
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION REGARDING LOUISIANA ENERGY SERVICES RISK ASSESSMENT FOR CLASSIFIED NETWORKS (ENTERPRISE PROJECT IDENTIFIER L-2021-LLL-0007)
Dear Wyatt Padgett:
The U.S. Nuclear Regulatory Commission (NRC) staff has reviewed the Louisiana Energy Services (LES), doing business as URENCO USA (UUSA), letter Submittal of Risk Assessment Report for Classified Systems, dated October 7, 2021, (Agencywide Documents Access and Management System Accession Number [Accession No. ML21286A133, Non-Public). The staff has also reviewed your response to the Request for Supplemental Information submitted via letter dated December 21, 2021 (Accession No. ML21361A044) and held discussions with UUSA staff on the draft RAIs during a site visit held April 19-21, 2022 (Accession No. ML22126A158, Non-Public). Our review of your application has identified that additional information is needed before final action can be taken.
The additional information, specified in the enclosure, should be provided within 30 days from the date of this letter. In addition to the RAIs, Security Categorization Report template has been incorporated as enclosure 2.
Pending your response, the proposed completion date has been revised from March 25, 2022, to July 30, 2022. This date could change depending on the findings of our technical review, urgent assignments, or other factors. We will promptly communicate any significant changes to this schedule.
This document transmits enclosures 1 and 2 which containing sensitive, unclassified information. When separated from the enclosures, this document is decontrolled.
May 20, 2022
OFFICIAL USE ONLY - SENSITIVE UNCLASSIFIED INFORMATION W. Pagett 2
OFFICIAL USE ONLY - SENSITIVE UNCLASSIFIED INFORMATION In accordance with 10 CFR 2.390 of the NRCs Agency Rules of Practice and Procedure, a copy of this letter will be available electronically for public inspection in the NRC Public Document Room (PDR) and in ADAMS. ADAMS is accessible from the NRC Web site at http://www.nrc.gov/reading-rm/adams.html. The PDR is open by appointment only. You may submit your request to the PDR via e-mail at PDR.Resource@nrc.gov or call 1 800 397-4209 between 8:00 a.m. and 4:00 p.m. (EST), Monday through Friday, except Federal holidays.
If you have any questions regarding this communication, please contact me at (301) 415-7154, or via e-mail to Matthew.Bartlett@nrc.gov.
Sincerely, Matthew Bartlett, Project Manager Fuel Facility Licensing Branch Division of Fuel Management Office of Nuclear Material Safety and Safeguards Docket No.: 07003103 License No.: SNM-2010
Enclosures:
- 1. Request for Additional Information
- 2. Security Categorization Report Template cc: LES@listmgr.nrc.gov Signed by Bartlett, Matthew on 05/20/22
ML22123A090 (Pkg) ML22123A091 (Ltr) ML22123A092 (Enc),
ML22123A090 (Encl. 2)
ML22123A090; Ltr ML22123A091 OFFICE NMSS/DFM/FFLB NMSS/DFM/FFLB OCIO/GEMSD/CSB
/CSOT OCIO/GEMSD/CSB NAME MBartlett ELee SFigueroa for MMangefrida GNalabandian DATE May 3, 2022 May 4, 2022 May 9, 2022 May 19, 2022 OFFICE NMSS/DFM/FFLB NMSS/DFM/FFLB NAME JZimmerman MBartlett DATE May 19, 2022 May 20, 2022