IR 05000416/2022012

From kanterella
(Redirected from ML22109A230)
Jump to navigation Jump to search
License Renewal Phase 1 NRC Inspection Report 05000416/2022012
ML22109A230
Person / Time
Site: Grand Gulf Entergy icon.png
Issue date: 04/20/2022
From: Nick Taylor
NRC Region 4
To: Franssen R
Entergy Operations
References
IR 2022012
Download: ML22109A230 (8)


Text

April 20, 2022

SUBJECT:

GRAND GULF NUCLEAR STATION - LICENSE RENEWAL PHASE 1 NRC INSPECTION REPORT 05000416/2022012

Dear Mr. Franssen:

On March 11, 2022, the U.S. Nuclear Regulatory Commission (NRC) completed an inspection at Grand Gulf Nuclear Station and discussed the results of this inspection with you and other members of your staff. The results of this inspection are documented in the enclosed report.

No findings or violations of more than minor significance were identified during this inspection.

This letter, its enclosure, and your response (if any) will be made available for public inspection and copying at http://www.nrc.gov/reading-rm/adams.html and at the NRC Public Document Room in accordance with Title 10 of the Code of Federal Regulations 2.390, Public Inspections, Exemptions, Requests for Withholding.

Sincerely, Nicholas H. Taylor, Chief Engineering Branch 2 Division of Operating Reactor Safety Docket No. 05000416 License No. NPF-29 Enclosure:

Inspection Report 05000416/2022012 Signed by Taylor, Nicholas on 04/20/22

ML22109A230 X SUNSI Review By: GAP ADAMS:

X Yes No Sensitive X Non-Sensitive Non-Publicly Available X Publicly Available Keyword NRC-002 OFFICE SRI:EB2 RI:EB2 C:EB2 C:PBC C:EB2 NAME G. Pick M. Chisolm N. Taylor J. Josey N. Taylor SIGNATURE

/RA/

/RA/

/RA/

/RA/

/RA/

DATE 4/20/22 4/20/22 4/20/22 4/19/2022 4/20/2022

Enclosure U.S. NUCLEAR REGULATORY COMMISSION

Inspection Report

Docket Number:

05000416

License Number:

NPF-29

Report Number:

05000416/2022012

Enterprise Identifier:

I-2022-012-0000

Licensee:

Entergy Operations, Inc

Facility:

Grand Gulf Nuclear Station

Location:

Port Gibson, MS

Inspection Dates:

March 7 to 11, 2022

Inspectors:

M. Chisolm, Reactor Inspector

G. Pick, Senior Reactor Inspector

Approved By:

Nicholas H. Taylor, Chief

Engineering Branch 2

Division of Operating Reactor Safety

SUMMARY

The U.S. Nuclear Regulatory Commission (NRC) continued monitoring the licensees performance by conducting a NRC inspection at Grand Gulf Nuclear Station, in accordance with the Reactor Oversight Process. The Reactor Oversight Process is the NRCs program for overseeing the safe operation of commercial nuclear power reactors. Refer to https://www.nrc.gov/reactors/operating/oversight.html for more information.

List of Findings and Violations

No findings or violations of more than minor significance were identified.

Additional Tracking Items

None.

INSPECTION SCOPES

Inspections were conducted using the appropriate portions of the inspection procedures (IPs) in effect at the beginning of the inspection unless otherwise noted. Currently approved IPs with their attached revision histories are located on the public website at http://www.nrc.gov/reading-rm/doc-collections/insp-manual/inspection-procedure/index.html. Samples were declared complete when the IP requirements most appropriate to the inspection activity were met consistent with Inspection Manual Chapter (IMC) 2515, Light-Water Reactor Inspection Program - Operations Phase. The inspectors reviewed selected procedures and records, observed activities, and interviewed personnel to assess licensee performance and compliance with Commission rules and regulations, license conditions, site procedures, and standards.

OTHER ACTIVITIES

- TEMPORARY INSTRUCTIONS, INFREQUENT AND ABNORMAL

===71003 - Post-Approval Site Inspection for License Renewal The inspectors evaluated the material condition of Unit 1 in the spring 2022 while the plant was shut down for Refueling Outage R23. This period allowed the inspectors to evaluate inaccessible areas prior to entry into the period of extended operation and to evaluate the licensee conducting aging management reviews. The period of extended operation is the additional 20 years beyond the original 40-year licensed term and begins after midnight on November 1, 2024.

In addition, the inspectors performed this inspection to evaluate whether the licensee:

(1) completed the necessary actions to comply with the license condition and commitments that are a part of the renewed operating license;
(2) implemented the aging management programs as described in the updated final safety analysis report; and
(3) implemented programs that agreed with those approved in the safety evaluation report and described in the updated final safety analysis report. Specific activities evaluated during this inspection are described in the following paragraphs.

The inspectors evaluated whether the licensee implemented the aging management programs described in NUREG-2211, Safety Evaluation Report Related to the License Renewal of Grand Gulf Nuclear Station, Unit 1, (ML16288A185). The inspectors verified that the licensee implemented procedures, documented inspection results, and initiated corrective action documents.

The inspectors reviewed supporting documents including implementing procedures, work orders, inspection reports, engineering evaluations, and condition reports; conducted interviews with licensee staff; and visually inspected structures, systems, and components including those not accessible during power operation to verify that the licensee completed the necessary actions to comply with the license conditions stipulated in the renewed facility operating license.

Post-Approval Site Inspection for License Renewal===

(1) The inspectors evaluated the aging management programs described below and walked down selected areas of the facility while performing this Phase 1 license renewal inspection.

A.1.23 Inservice Inspection Program The Inservice Inspection Program manages aging effects for ASME Class 1, 2, and 3 pressure-retaining components including welds, pump casings, valve bodies, integral attachments, and pressure-retaining bolting using volumetric, surface, or visual examination as specified in ASME Section XI code. Every ten years this program is updated to the latest ASME Section XI code edition and addendum approved by the NRC in 10 CFR 50.55a.

The inspectors reviewed this program to ensure that the licensee would continue to manage the effects of aging during the period of extended operation. The inspectors verified that this program had no enhancements and no exceptions. The inspectors identified no issues during review of this aging management program.

A.1.34 One-Time Inspection - Small-Bore Piping Program and Commitment 24 This program provides a one-time volumetric inspection of a sample of Class 1 piping locations that are susceptible to cracking. The program includes pipes, fittings, branch connections, and all full and partial penetration (socket) welds with a nominal pipe size diameter less than 4 inches (NPS < 4) and greater than or equal to NPS 1 in systems that have not experienced cracking of ASME Code Class 1 small-bore piping.

Commitment 24 specified, Implement the One-Time Inspection - Small-Bore Piping Program for Grand Gulf Nuclear Station (GGNS) as described in License Renewal Application (LRA) Section B.1.34.

Because the licensee had not had any failures of their small-bore piping welds after 30 years of operation, the licensee decreased their sample population as allowed by the Generic Aging Lessons Learned report. The licensee decreased the sample size for their volumetric examinations from 10 percent, with a maximum of 25, of the socket welds and 10 percent, with a maximum of 25, of the butt welds to 3 percent with a maximum of 10 socket welds and 3 percent with a maximum of 10 butt welds. The inspectors determined that, during ultrasonic examination of a 3-inch carbon steel butt weld (DBA-23, FW-11), the licensee had identified an internal diameter connected flaw. The licensee documented this deficiency in Condition Report GGN-2022-02194. Because the licensee had an initial sample population of seven welds, the licensee doubled the sample population.

Based on review of the actions implemented related to the Small-Bore Piping Program, the inspectors could not determine whether the licensee met their commitment since all the inspections had not been completed at the time of the inspection. This commitment will be reviewed during the Phase 2 inspection.

Plant Condition Monitoring Walkdowns The inspectors walked down the facility looking at the structures, systems, and components for signs of aging, such as corrosion on piping and supports, corrosion of cable trays, water intrusion, cracking, and spalling of concrete.

Specific areas walked down and components evaluated during this inspection included:

Drywell - multiple elevations

Suppression Pool

Turbine Condenser Bay

Inside Turbine-Generator Bioshield During the walk downs of the areas, the inspectors did not identify any signs of aging that affected the structures, systems, or components.

INSPECTION RESULTS

No findings were identified.

EXIT MEETINGS AND DEBRIEFS

The inspectors verified no proprietary information was retained or documented in this report.

On March 11, 2022, the inspectors presented the NRC inspection results to Robert Franssen and other members of the licensee staff.

DOCUMENTS REVIEWED

Inspection

Procedure

Type

Designation

Description or Title

Revision

71003

Corrective Action

Documents

CR-GGN-

22-02113, 2022-02194

Drawings

M-1070A

Standby Diesel Generator System

Engineering

Evaluations

GGNS-EP-08-

LRD05

Aging Management Program Evaluation Report Class I

Mechanical, Section 4.8, Inservice Inspection

GGNS-ME-19-

00023

Review of the Inservice Inspection Program for License

Renewal Implementation

GGNS-ME-19-

00034

Review of One-Time Inspection - Small-Bore Piping Program for

License Renewal Implementation

GGNS-ME-19-

00042

Review of the Structures Monitoring Program for License

Renewal Implementation

Miscellaneous

NUREG-2211

Safety Evaluation Report Related to the License Renewal of

Grand Gulf Nuclear Station, Unit 1

Procedures

CEP-ISI-100

ASME Section XI, Division 1, Fleet Administrative Controls for

Inservice Inspection Program

EN-DC-150

Condition Monitoring of Maintenance Rule Structures

EN-DC-351

Inservice Inspection Program Duties and Responsibilities

EN-FAP-LR-024

One-Time Inspection

EN-MA-145

Maintenance Standard for Torque Applications

LMT-21-PAUT-

29

Encoded Phased Array Ultrasonic Examination of Small Bore

Austenitic and Ferritic Socket Welds (= 2.0? OD NPS)

SEP-ISI-GGNS-

001

ASME Section XI, Division 1, GGNS Inservice Inspection

Program

Work Orders

00541780