80 81 82 83 84 85 86 87 88 89 MIXED BED DEMINS RESIN SAMPLERS U-2 RESIN SAMPLERS U-2 RESIN SAMPLERS

( ISOLOK AUTO SAMPLER (DWG 108019) S2-3333-21/2 I9 U-1 STM GEN 52 _4344 _2 DC-6981 06-1 I I DWG I O8 0 I 9 I TO c- 88 -c 04 >-----I....--, V-1 I A NOTE 6 S2-3335-2 1/2 UNIT 2 80 86 S2-3334-21/2 88 19 79 -D 08 84A-A SPENT RESIN -c EDUCTORS LOADOUT S2-1597-21/2 -c EL, I 15, -0" S2-3323-2 BW SEAL 19 19 2-1 & 2-2 U-1 DEMINERALIZERS 1-2 GLAND (DWG 108019) NOTE 8 S2-3331-21/2 [8J S2-3333-21/2 A V-IOA V-153A S2-3327-2 16 V-12A 85A -A TEST 85A -A

- RV-48 A

Du SPENT RESIN FCV-1 306A S2-3486-21/2 S2-2142-21/2 RV-50 DEWATER ING EDUCTORS ( 452E -A 32)

I S2-1597-21/2 S2-5878-4 PUMP RETURN S2-3479-2 DC-663270-35 SEAL S2-3343-11/2 GLAND S2-3344-11/2 ------..(S2A-C(

V-10B V-153B I- I S2-3332-21/2 S2-3332-21/2 [8J S2-3335-21/2 U-1 DEMINERALIZERS S2-3328-2 16

...___,---.303 FI f'-------,

85A -A TEST 85A -A S2-3334-21/2

-- (161C-Bl34)

- (274B-E 33)

I S2-5869-3/4

( I 64C-B 34)

FCV- I 308A nv I EL, I 00' -0" S2-3324-2 BW 79 -A 08 Du

( 456E -A I 32)

(272B-E 33)

LT I PT 65 nV 16 16 A6

&'h S2-3920-1 1/2 (ITT S2-3597-2 V-11B A 6 3I S2-3919-11/2 S2-3485-11/2 Yv-14D 65B -D >---....----' &L V-l 4A V-14B S2-3484-21/2 (278B-E I 33)

RADWASTE ION V V V EXCHANGER 0-1 LT vn nv V-1 76B 28 nv S2-3921-3/4 16 16 V-1 76C V-1 76D s s- 16 V-80 S2-3923-1 S2-3924-I 14

~

1 S2 RESIN SAMPLE ((ill RESIN SAMPLE RETURN V-85 V-88 S2-3926-1 LT RETURN B 86A -A >-------, I0 S2-3/4 S2-3/4 (278E-A 33) I 057 I

IO t--- 86A-A B S5-2 STRAINER STRAINER S5-2 BW 4" 14" BW V-86 STRAINER V-87Ml---t-r'---+---- STRAINER

~ 6 V-156B S2-3071-11/2 i---- 82A -B) 6 SPENT RESIN STORAGE TANK 611 P-0120 y.lEJ 4

[El ~G&E S2-3/4 V-55C V-51A nV V-51B S2-3/4 PG&~*

V-55D E

H i

P-0120 6"

SPENT RESIN STORAGE TANK V-21B 28 MOTIVE WATER TO S2-5870-3/4 0-1 5_.._ S2-3482-11/2 V-159 S2-3483-11/2

-{><}---- -A5 0-2 LOADOUT EDUCTOR 0-2 DC-663270-42 &'h DC-663270-40 NOTE 7 u D NOTE I 0 -2

- -{><}----

llf-2 NOTE STRAINER S2-1640-1 1/2 V-55A V-160 S2-3336-11/2 V-55B STRAINER NOTE 10 7 28 22 3" Du 3/4X42D 3"

,______.,___, V- 36A u D NOTE 9

NOTE V-36B FCV 9 NOTE 12 2 Du u D 2 1056 (LOCATED V-6B I LOCATED FCV NOTE 12 INSIDE V-37A

  • PGE PGE
  • INSIDE S2-3337-3 H S2 1057 TANK ROOMI V-6A  :,-------+1-1 V-37B TANK ROOMI S2-3338-3 E s S-2 S-2 C D D ( 447M-E 32)

I C

86A RESIN S2-3070-2 82A LOADOUT l_jJ l_jJ vn V-35 S2-3383-11/2 SAMPLERS S2-3383- I 1/2 BW EDUCTOR 0-1 S2-5872-3


-------- V-166 S2-3385- I1/2 V-29 S2-1588-2 28 S2-3340-11/2

-....t-----~78IA-B MOTIVE WATER TO 28 V- I 5 7 V-23 ~~ NOTE 9 V-21A V-156A LOADOUT EDUCTOR 0-1 u D S2-3475- I1/2 83A LOADOUT Vn

r14x420 l_jJ EDUCTOR 0-2 FLUSH WATER n V nV ISOLOK (FROM PROCESSED HCV RESIN 86A WASTE PUMPS! 28 STR S2-3355-11/2 130 28 S2-3475-11/2 V-163 S2-3386-11/2 SAMPLERS l_jJ 65 -D ").-----"--1 PI 22 31 S2-3355-I1/2 V-70 V-151 V-33 LJ Vn S2-3382-3 NOTES:

D u28 16 tE- C-0250 V-175A V-25A I, EQUIPMENT, VALVES, & INSTRUMENT TO BE PROVIDED BY CNS/NSA; PG&E PRO-S2-3355-I1/2 VIDES THE PIPING, SEE DWG, 101935 INSA VALVE INVENTORY),( 80-E)

BIA

( 452B-A 32) S2-3375-11/2 2, 'BW' DENOTES BUTTWELDED (ALL 2 LINES CARRYING SPENT RESIN TO AVOID

~

I SLUICE WATER S2-3151-3/4 28 FCV-63 S2-3339-3 ENTRAPMENT OF RESIN AT JOINTS!,

BOA FOR u D SERVI CE 82 A V" D S2-4008-1 V-149 l_jJ RESIN DISPOSAL AIR ~ SPENT RESIN V-175C 16 V-25C nV 16 3, VALVE POSITIONS ARE SHOWN WITH THE SPENT RESIN STORAGE TANKS 0-1 & 0-2 IN THE FILLING AND LOADOUT OPERATIONS RESPECTIVELY, D

nV TRANSFER S2-3479-2 V-77 PCV- FILTERS V-175B 4, PG & E VALVES WITH ITEM NUMBERS ARE SPECIFIED ON SPEC, 0722,

  • -A"°"2 28

&ll S2-11/2 I ' -___, _ 16 ~-~ OVERFLOW LJ S2-3379-3 S2-3374-1 1/2 5, ALL PIPING ON THIS SHEET SHALL BE PG&E CODE CLASS H, EXCEPT ISOLOK D V-25B S2-3376-1 1/2 AUTO SAMPLING SYSTEM, & AS NOTED, RV-40 f-lo-~- 83A -c FILTERS S2-1800-3 S2-4009-2 BYPASS V-158A nV 6, AUTOMATIC RESIN SAMPLE COLLECTION DEVICES I PG&E CODE CLASS "E" I ARE V-158C A2 NOTE I I NOTE I I LOCATED AT COORDINATES: ( 82 _A) 3/4X42D V-25D 16 V-175D S2-3378-3 vn ~ PX S2-3475-11/2

~--- , ., =t=

393 7,3/4 "0 BALL VALVE,PITTSBURG BRASS CO, MODEL SPH-I3-BW-XXS 2/0ESL(83+89-C)

P-0120 R-0186 21 ..=i1e-

  • S2 392 PX S2-3377- 8, 2"DIAM, 3-WAY BALL VALVE, BW ENDS, PITTSBURG BRASS MANUFACTURING CO,

~,~~~ ~ S2-3549-3 S2-1626-4_~ V-I MODEL NO,MP-H-17 BW/2 PO/CO/OE/IS FLOW PATTERN N0,2, 316 SS, ( 82-A) ro 3/4X42D Du Du P-0120 S2-3477-2

~

s2 - 3 47 8 -2 A2 0- I (~---, ,----,

(SEETYP, DRAINS ON SRMW PP 0-2 I c?, H START-UP 6 6

t--r-,---;--1----<; 64 -c Du 28 PROCESSED WASTE V-22C

~

A I6 S2-5878-4 NOT 9, 3" BALL VALVE PITTSBURGH BRASS MODEL #SPH-19-BW I IOI 2/0E SI FP, 316 SS, 10, SCH XXS, ( B3-C)( 89-C) 11, CHECK VALVE INTERNALS REMOVED. ( 85-D)( 87-E)

( 87-C) ( B4-C) m 12, 1/20 PLUG VALVE,300# 316 SS XOMOX MODEL 0366 SW,UHMW SLEEVE IP-01201 m S2

  • STRAINERS RECEIVERS W/ MODEL 60 ACTUATOR, ( 83-C) ( 89-C)

~ ~ ~

ro' S2-1248-4 0 17~~ ,,., S2-3514-3 S2-1249-4 0 _2

~E G)

+-

p _0 I 20 R-0 I 86 (:s:-+-4---t r----r1 11 16....__.,,, 600# FLNG S2-3550-3 28 t-'-t-r---~ 64 -c S2-1627-4 UNIT E 0 ou D[...,.-11-+- I TYP, 4 I D

iH7 y2 PX Du S2-5863-21/2 m t5 BY CNS/NSA BY PG&E W CASI NG 28 SEAL 267 SPENT RESIN SRTF

\i' ": NOTE I ORA IN l'\.IA ORA IN

'.-:3;

~"'

~~

1 1 TO 5~ sH. TO AUX, MISC,EQUIP,1_ 44 '11-slBLDG, DRN,TK,o-1vvsuMP MOTIVE WATER PPS DC-663268-1 FILTERS B4A BYPASS I-cl v ~

PG SHEET O

Sex E

PAGE CO O"

020 9 82' REV

-*3N,..PG'"'IC---------------------------------------,,--------------------------"""T--------------------------r------....1-------"T'".....,______...,_____T""_ _ _ _ _ _ _ _..._...._....___~

6/ I I /98 CMG9 BSG I KERS I J, DALAL MECHANICAL M I 6690 3/3 I /00 Revised pe, FCT 023040 1----A_T_E--t---W-N-+-R-E-t--I-V-t---=-p-=-R----:O-=F-=E----:S----:S--::-I----:O----=N-A-L----=-E----=NG----IN----=-EE=cR::-----t-----:P:-:E:--::D----=1----=s----=c----=.-----t-----:P::cE=c,,---------t-P::cE::--E=cX----:P::c.-------J