40 41 42 43 44 45 46 47 48 49

~

c-1

~-------------'T-T-~---

EL.93' 1

~~Pi7~T~~~~NT AUXILIARY BLDG EL.sg*

i C ,1 I -;4 NOTE 6 FUEL HANDLING BUILDING rI ___ c2~~-

~ C-3234-2 i::

I C-1600-2

___ ..,+/--_~

ic-2525-1 C-3237-2 CONT PURGE TO VENTILATION C- 3623 - 2 T ... C-3128-2 ROOM r""1---1[::.EL.1--------------------------------------------------iD I

1 I c-31 19-2 I I I' -5" WHITEY S.S.' 44S6

~ 45C3 45V I I I K-3129-3 A EL, II O '

C-3624-2 EL. 9 4 '

.J I

,!, S-3/a NOTE 7 EL. 85'

-EL. 89' RUB HOSE CONN 45VI Jv A

~----------r--

C-3624-2 C-21 I I - I K-1114-4 FILTER PACKAGING STATION AIR PALLET K-1658-1 K-1930-1 K-3238-3 EL, 140' K-I K-3235-2 K-2997-2 K-2789-2 K-2577-1 TO SPENT 28-C 13 FUEL GATE

-~-~-~.J /\I 11 CNT PURGE Lili 25' PS I TO SPENT FUEL TO SPENT FUEL SEAL POOL SUMP PIT POOL GATE SEAL EL. 140' 25C2 C-3322-1 K-3/4 TO CASK TO AUXILIARY K-3459-2 DECONTAMINATION K-1864-2 45VI CONTROL BOARD K-2 AREA OPEN TO DEFLATE SEALS

( TYP l I 50.tt FLANGE NOTE 7 K-3232-4 EL. I 04' K-2094-2 K-3466-2 TC TC EL. 89' Cs.2_ ,,S~3/a

@; (s) L_B s-1/, ffi- ,,S-1/,

1+--+--'----'-'---'--""-'--"--'---'--K"---4'--'o..C8.C.5_-'-,I- EL. 144, E HI PRESSURE C-0656 ITEM B ~ ITEM N, BOTTLES ITEM K-3/4 K2-3/4 I I K2-3/4 I0 WI TH REGULA TOR 19, I B K-5390-1 RADWASTE K2-3941-3 K-2382-3 B

ION EXCHANGE

~,

K-3512-1

/

/

K-3455-11/,

K-1889-1 K-3511 -I ' \

\

\

EL, 143'

f. \

\

K-750-2 \

K-754-2 \

\

K-1 I

C K-3699-1 I C EL.56' I I

I I

K-2058-3 I

I I

K-3123-2 EL. I 4 7 0 0 N

0 0

N I

N ALL INSTRUMENT AIR HEADER WJTH L SPEC "C" ARE R-0182. ALL 0

ABOVE SERVJCE AlR HEADER VALVES JNE SPEC I

"K" ARE R-0181. 2" AND BELOW SERVICE AlR VALVES Lil ARE P-0 181 EXCEPT AS NOTED,~

2. ALL VALVES WJTH ITEM NOS. ARE UNDER SPEC 8729 TURBINE BUILDING REFER TO PG&E DWG I 02039 EXCEPT AS NOTED.

Q)

3. SARACO TANK CO, SERIAL NO. NB 872c1.

+- C-3045-2 C-2141-2 '1. 3/4" WATTS, NO. 8252 0 1 -&-

EL.119' 5. 3" UNITED, NO. 12 A3 0 t+--+-0-0-K*--- T O LO RESERVOIR NUPRO PLUG VALVE B-6P6T 3/s"T 6 1

C-2144- 4692 1/.

z 7. REFER TO PG&E DWG Oc19096 FIG. 616~

CHECK VALVE, STOCK CODE 9c1-1510, N (_'J I 8. DWG 6011166-1~

CJ)

X 0

E ,--!><J----------i C-3239-3 f+C::..-_4:..::8:.::8.:..1_;-2=---t>(]-c-o;2~.z!8;i_:c;');~L- TO TECH SUPPL y I NSTRUMEN:-:: :5-2t E

L L

Q)

If)

~

V)

Lil N

(TYP) SEE NOTE I K- _

3240 4

-~~~---------- K-3226-4

~~~~----~~~~~C-2148-3 UNIT 2 0

J CD II WEST REV, z R-0181 P G & E CO.

108025 36 0

(_'J K-3224-3 I

<C 3" u 0 SHEET 4 PAGE 0 INPGIC 5/2/02 RXG2 RHSI KERSI Jo DALAL MECHANICAL M 16690 3/3 I /200"1 (ev i sed per FCT 026"161 DATE OWN RE IV PROFESSIONAL ENGINEER PE DISCO PE it