MONTHYEARML21070A0502021-03-11011 March 2021 Notice of Pre-Application Meeting for the Crystal River 3 Reactor Pressure Vessel Package Project stage: Meeting PMNS20210594, 5/25/21 Notice of Pre-Application Meeting for the Crystal River 3 Reactor Pressure Vessel Package2021-05-0404 May 2021 5/25/21 Notice of Pre-Application Meeting for the Crystal River 3 Reactor Pressure Vessel Package Project stage: Meeting ML21160A0812021-06-0909 June 2021 Summary of May 25, 2021 Meeting with Orano Federal Services Encl 1 Meeting Attendees Project stage: Meeting ML21160A0822021-06-11011 June 2021 Encl 2: Public Presentation - CR3MP Crystal River 3 Middle Package 2nd NRC Meeting Project stage: Meeting ML21244A4852021-08-31031 August 2021, 1 September 2021 Orano Federal Services, LLC, Submittal of Safety Analysis Report for the CR3MP Package, Rev. 0 Project stage: Request ML21244A4892021-08-31031 August 2021 Orano Federal Services, LLC, CR3MP Safety Analysis Report, Revision 0 Project stage: Other ML21244A4862021-09-0101 September 2021 Orano Federal Services, LLC, Submittal of Safety Analysis Report for the CR3MP Package, Rev. 0 Project stage: Other ML21244A4872021-09-0101 September 2021 Orano Federal Services, LLC, Affidavit Project stage: Other ML21286A8002021-10-15015 October 2021 Enclosure 1 - Request for Supplemental Information and Observation for the Model No. CR3MP Package Project stage: Other ML21286A7982021-10-15015 October 2021 Request for Supplemental Information for the Review of the CR3MP Package Project stage: Request ML21286A7992021-10-15015 October 2021 Request for Supplemental Information for the Review of the CR3MP Package Project stage: Approval ML22006A3662021-12-22022 December 2021 Enclosure 1: Affidavit Pursuant to 10 CFR 2.390 Project stage: Other ML22006A3652022-01-0606 January 2022 Orano Federal Services, LLC, Response to Request for Supplemental Information for the Review of the Model No. CR3MP Package Project stage: Supplement ML22033A5412022-01-31031 January 2022 Orano Federal Services, LLC, Table of Changes for CR3MP Safety Analysis Report, Revision 2 Project stage: Other ML22006A3692022-01-31031 January 2022 Enclosure 4: CR3MP Transport Package Safety Analysis Report, Revision 1 Project stage: Other ML22006A3702022-01-31031 January 2022 Enclosure 5: Table of Changes for CR3MP SAR Revision 1 Project stage: Other ML22033A5372022-02-0202 February 2022 Review of the Orano Federal Services Updated Safety Analysis Report (Revision 2) for the Model No. CR3MP Package Project stage: Other ML22175A0442022-06-24024 June 2022 Letter Request for Additional Information for the Review of the Model No. CR3MP Package Project stage: RAI ML22356A3132022-12-19019 December 2022 Orano Federal Services, LLC Submittal of RAI Responses and SAR Revision 3 for the CR3MP Package Project stage: Other ML22356A3182022-12-19019 December 2022 Enclosure 5 - Table of Changes for CR3MP SAR Revision 3 Project stage: Other ML22356A3142022-12-19019 December 2022 Enclosure 1 - Responses to NRC Request for Additional Information on the Model No. CR3MP License Project stage: Response to RAI ML22356A3162022-12-31031 December 2022 Enclosure 3 - CR3MP Transport Package Safety Analysis Report, Revision 3 Project stage: Other ML23113A0122023-05-0202 May 2023 Encl 1 - Request for Additional Information CR3MP Project stage: RAI ML23159A2772023-05-31031 May 2023 Enclosure 4: CR3MP Transport Package Safety Analysis Report, Revision 4 (Non-Proprietary Version) Project stage: Other ML23159A2752023-06-0808 June 2023 Enclosure 2 - Non-Proprietary Responses to NRCs Second Request for Additional Information on the Model No. CR3MP License Application Project stage: Request ML23159A2732023-06-0808 June 2023 Orano Federal Services, LLC Response to Second Round Request for Additional Information for the Review of the Model No. CR3MP Package Project stage: Request ML23208A1472023-08-0404 August 2023 Special Package Authorization for the CR3 Middle Package(CR3MP) - Docket No. 71-9393 Project stage: Other ML23208A1442023-08-0404 August 2023 Special Authorization for the Crystal River 3 Middle Package CR3MP Project stage: Request ML24109A2992024-04-18018 April 2024 Orano Federal Services, LLC - Request for Extension of CR3MP Special Package Authorization, EPID L-2021-NEW-0003 Project stage: Request 2022-01-06
[Table View] |
Text
Enclosure Request for Supplemental Information and Observation for the Model No. CR3MP Package Docket No. 71-9393 This request for supplemental information (RSI) identifies information needed by the staff in connection with its acceptance review of the Crystal River 3 Middle Package (CR3MP). Orano Federal Services LLC (Orano FS) submitted an application for approval of the CR3MP package, as a Type B(U)-96 Package under 10 CFR 71.41(d). The CR3MP will transport a segment of the Crystal River 3 decommissioned reactor vessel to a disposal site.
Request for Supplemental Information RSI-1 Provide the information that was used to determine the packages fixed and loose surface contamination activities reported in the application.
The premise of the containment analyses was a surface contamination value. SAR Section 1.2.2.3 and Section 5.2 indicated that surrogate data and empirical samples were used to estimate the surface contamination. A detailed discussion of the data and empirical samples that demonstrate the bounding nature of the dispersible activity (which includes fixed and loose surface contamination) was not provided.
This information is needed to determine compliance with 10 CFR 71.47(b), 71.51(a)(b).
RSI-2 Provide the supporting information that justifies the hydrogen concentration produced in the package and address relevant analyses that were not provided or considered.
The focus of the applications hydrogen generation calculation was the effect from grout, which is introduced into the RPV after it is drained of water, according to SAR Section 1.2.2.2. Specifically, Section 5.4.4 of the application stated that the analysis was based on the gas generated per energy absorbed parameter (G) for the cement-based grout.
However, the radiolysis discussion did not address the following considerations:
- a.
The application did not quantify free (unbound) water within the package or address that free water often forms during processes that use cement. The radiolysis analysis should consider the effects of unbound (free) water, recognizing that water (liquid, vapor) has a (G) value of approximately 0.45 molecules/100 eV (gamma), which is much higher than the SARs stated (G) value for grout (0.02 molecules/100 eV (gamma)).
- b.
The application referenced a paper (Dole and Friedman, 1986) when determining the grouts (G) value. However, other papers (see EPRI NP-5977, September 1988) have indicated (G) values ranging from 0.11 to 0.35 molecules/100 eV.
There was no discussion that justified the use of the Dole and Friedman (G) value (0.02 molecules/100 eV) for the CR3MP grout rather than other values (e.g., 0.35 molecules/100 eV).
- c.
According to Section 5.4.4 of the application, the radiolysis calculation only considered the effect of gamma energy because it represented the majority of the contents energy; other types of radiation energy (e.g., alpha) accounted for 4% of the total. The impact on the radiolysis calculation from the other energy components may not be negligible because the applications cited radiolysis document (Dole and Friedman, 1986) noted that the grouts (G) value for alpha energy potentially could be approximately 23 times greater than the gamma energy-related (G) value.
This information is needed to demonstrate compliance with 10 CFR 71.43.