Date : 10/4/2021 Distribution: Duke Energy Document Transmittal#: TR*NUC-CN-013013

1. (CNS) U S NUC REG WASHINGTON DC
2. Andrews, Sherry E DOCUMENTTRANSMITTALFORM

Purpose:

~

3. Byers, Kristi S Released By:
4. CNS - WCC/SSA Facility : CATAWBA NUCLEAR STATION Duke Energy
5. CNS C/ R DWGS. SSA SUBJECT 4800 C2ni;2rd R21d
6. CNS COMPL FILE (ORIG)X SLC Manual Revision 12 LOES i!nd 16.13*4 Q2i;umeat M101gemeot
7. CNS DOC MGMT CN04DM
8. CNS OPS SUPPORT GROUP Y2rk, SC 2iZ4S
9. CNS RP LIBRARY CNSDCBM@duke-energy.i;2m
10. CNS RP SHIFT LAB
11. CNS RP SHIFT OFFICE
12. CONTROL ROOM SSA
13. Edmond, Russell L
14. Lowery, Tonya Sul livan
15. Mironenko, Artur N
16. OPS TRAI NI NG
17. Owens, Lori
18. Pursley, Sandy
19. WESTINGHOUSE ELECTRIC CO LLC Page 1 of 1 Document ID 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 LICN - CN - CNS-SLC* 16. 13 004 - ISSUED FYIIE FYIIE FYII E FYI ILP FYIIE FYI IE FYIIE FYIIE FYIIE FYIIE FYI IE FYI ILP FYIIE FYIIE FYIIE FYIIE FYI IE FYIIE FYI IE LICN - CN - CNS-SLC-LOES - 102 - ISSUED FYI IE FYI IE FYIIE FYI ILP FYIIE FYI IE FYIIE FYI IE FYI IE FYIIE FYI IE FYI ILP FYI IE FYIIE FYI IE FYIIE FYII E FYIIE FYII E LICN - CN - SLC Letter to Manual Holders - FYI IE FYII E FYI IE FYI ILP FYII E FYI IE FYI IE FYII E FYII E FYII E FYI IE FYI ILP FYI IE FYI IE FYII E FYII E FYI IE FYII E FYII E 102 - ISSUED Remarks:

Remove and Insert Replace the following page(s) of Catawba Nuclear Station Selected Licensee Commitments (SLC) Manual with the attached revised page(s). The revised page(s) are identified by Section

  • number and contains marginal lines indicating the areas of change.

REMOVE THESE PAGES INSERT THESE PAGES LIST OF EFFECTIVE SECTIONS Pages 1-5 Pages 1-5 Revision 101 Revision 102 TAB 16.13 16.1~, Pages 1-6 16.13-4, Pages 1-6 Revision 3 Revision 4 If you have any questions concerning the contents of this Catawba Nuclear Station Selected Licensee Commitments {SLC) Manual update, please contact Nicole Edwards (704) 591-3907.

LIST OF EFFECTIVE SECTIONS SECTION REVISION NUMBER REVISION DATE TABLE OF CONTENTS 15 05/10/16 16.1 1 08/27/08 16.2 2 08/21/09 16.3 -1 08/21/09 16.5-1 7 03/30/21 16.5-2 Deleted 16.5-3 2 09/19/19 16.5-4 0 10/09/02 16.5-5 1 01/28/10 16.5-6 1 08/21/09 16.5-7 2 02/06/15 16.5-8 Deleted 16.5-9 Deleted 03/02/21 16.5-10 Deleted 16.6-1 0 10/09/02 16.6-2 Deleted 16.6-3 1 08/21/09 16.6-4

~"'_;

2 11/21/19 16.6-5 3 07/07/20 16.7-1 1 08/21/09 16.7-2 4 02/03/11 16.7-3 5 11/21/19 16.7-4 2 08/21/09 16.7-5 5 04/20/21 Catawba Units 1 and 2 Page 1 Revision 102

LIST OF EFFECTIVE SECTIONS SECTION REVISION NUMBER REVISION DATE 16.7-6 3 06/10/16 16.7-7 1 08/21/09 16.7-8 2 08/21/09 16.7-9 13 09/14/21 16.7-10 9 04/23/20 16.7-11 1 08/21/09 16.7-12 1 08/21/09 16.7-13 3 06/10/16 16.7-14 1 08/21/09 16.7-15 1 08/21/09 16.7-16 0 06/08/09 16.7-17 0 02/10/15 16.7-18 0 05/10/16 16.8-1 7 06/01/20 16.8-2 3 12/18/19 16.8-3 1 10/24/06 16.8-4 2 11/05/07 16.8-5 3 08/21/09 16.9-1 10 01/29/19 16 9-2 6 08/03/17 16.9-3 5 07/03/18 16.9-4 5 09/11/17 16 9-5 11 10/08/19 16.9-6 12 07/03/18 Catawba Units 1 and 2 Page 2 Revision 102

LIST OF EFFECTIVE SECTIONS SECTION REVISION NUMBER REVISION DATE 16.9-7 4 08/21/09 16.9-8 5 08/21/09 16.9-9 3 08/21/09 16.9-10 5 08/21/09 16.9-11 3 08/21/09 16.9-12 3 02/10/15 16.9-13 4 09/27/16 16.9-14 1 09/25/06 16.9-15 2 08/21/09 16.9-16 2 08/21/09 16.9-17 0 10/09/02 16.9-18 Deleted 16.9-19 3 02/20/12 16.9-20 0 10/09/02 16.9-21 1 10/13/16 16.9-22 1 08/21/09 16.9-23 5 08/03/17 16.9-24 2 10/24/06 16.9-25 2 08/21/09 16.9-26 1 11/15/18 16.10-1 1 08/21/09 16.10-2 1 10/24/06 16.10-3 1 08/21/09 16.10-4 0 08/04/20 Catawba Units 1 and 2 Page 3 Revision 102

LIST OF EFFECTIVE SECTIONS SECTION REVISION NUMBER REVISION DATE 16.10-5 1 03/16/21 16.11-1 1 07/27/13 16.11-2 6 05/13/21 16.11-3 0 10/09/02 16.11-4 1 08/21/09 16.11-5 0 10/09/02 16.11-6 3 08/03/15 16.11-7 12 08/06/20 16.11-8 0 10/09/02 16.11-9 0 10/09/02 16.11-10 1 08/21/09 16.11-11 1 03/20/03 16.11-12 0 10/09/02 16.11-13 1 07/27/13 16.11-14 0 10/09/02 16.11-15 0 10/09/02 16.11-16 1 10/24/11 16.11-17 0 10/09/02 16.11-18 1 08/21/09 16.11-19 0 10/09/02 16.11-20 3 11/21/19 16.11-21 0 10/09/02 16.12-1 0 10/09/02 16.13-1 1 08/03/17 16.13-2 Deleted Catawba Units 1 and 2 Page4 Revision 102

LIST OF EFFECTIVE SECTIONS SECTION REVISION NUMBER REVISION DATE 16.13-3 Deleted 16.13-4 4 10/04/21 Catawba Units 1 and 2 Page 5 Revision 102

Minimum Station Staffing Requirements 16.13-4 16.13 C_ONDUCT OF OPERATIONS 16.13-4 Minimum Station Staffing Requirements COMMITMENT Minimum station on shift staffing shall be as indicated in Table 16.13-4-1.

APPLICABILITY: According to Table 16.13-4-1.

REMEDIAL ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A. Minimum station staffing A.1 Initiate action to fill required Immediately requirements not met. positions.

A.2 Restore minimum station 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> staffing levels.

TESTING REQUIREMENTS TEST FREQUENCY TR 16.13-4-1 Verify stationon shift staffing levels. 12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> Catawba Units 1 and 2 16.13-4-1 Revision ~

Minimum Station Staffing Requirements 16.13-4 Table 16.13-4-1 Minimum Station Staffing Requirements POSITION BOTH UNITS IN. ONE UNIT IN MODES BOTH UNITS IN MODES 1-4 1-4 MODES 5, 6, OR NO MODE Operabons Shift Manager (GSM)

Shift T echnlcal Advisor (STA)

Semor Reactor Operator (SRO)<1J(2)(:J) 2 2 Reactor Operator (RO)(1l(~l 3 3 2 Non-Licensed Operator (NhQA_Q)(1l!§l 5 5 4 Shift Communicator 1 1 1 Fire Brigade Leader1J 1 1 1 F1re Bnqade Memoorei 1 1 1 Chemistry Technician Radiation Protection Qualmed lndMdual 2 2 2 (Note 5)

Qese-Asses6ment Quakfied lndMdual 4 1-Mechanical Maintenance Technician Instrumentation and Electncal Technician 2 2 2 Medical Emergency Response Team 2 2 2 (MEAT)

Secunty Personnel Per Secunty Plan Per Security Plan Per Secunty Plan (1) Either a SRO (active or Inactive), RO, or other designated personnel (NLO) may be designated as the flre bngade leader. The totals for the appropnate position shall be increased by one, depending upon wt11ch position is bemg used to fulfill the role of flre brigade leader (2) In addltlon to these requirements, dunng CORE ALTERATIONS (1ncludlng fuel loading or transfer), a SRO or SRO llmrted to fuel handling shall be present to directly supervise the activity. Dunng this time, no other duties shall be assigned to this person.

(3) Wrth any unit In MODES 1-4, a SRO shall be present In the control room at all times Catawba Units 1 and 2 16.13-4-2 Revision ~

Minimum Station Staffing Requirements 16.13-4 (4) For each fueled unit, a RO shall be present at the controls at all times.

(5) One RP Qualified lndMdual must meat or exceed RP Technician minimum ANSI quahftcatlons per Technical Spectftcabon 5.2.2.d.

(Sill Of the 5 requlrecl AOs, three are required by TS 5.2.2.a and 2 are required by the fire protection program and SLC 16.13-1 "Fire Br1gade".

Catawba Units 1 and 2 16.13-4-3 Revision ~

Minimum Station Staffing Requirements 16.13-4 BASES The requirements of this SLC consolidate Catawba station staffing requirements into one document. This SLC includes tho unit staff requirements of tho Catmvba Fao11ity Operating Licenses, Technical Speoifioation (TS) 6.2.2, 10 CFR 50.54(m), applicable Operations Management Prooedurec (OMPs), Administrative Direotivo (AD) AD TQ ALL 0086, "Fire Brigade Training," tho Gata1Nba Fire Protection Program, tho Catawba Emorgenoy Plan, and SLC 16.13 1, "Fire Bngado." Tho total requirement for oaoh position was obtained by summing tho various individual requirements for that position. The bases for the numbers in the first column of Table 16.13-4-1 are as follows:

1 GSM (active SRO) - Required by 10 CFR. 50.54(m)(2}(ii) and the Fleet Common Emergency Planimplemented via OMP.

1 S+A-STA - Required by TS 5.2.2g and implemented via OMP and tho Fleet Common Emergency Pan. The STA is assigned collateral ERO functions of Shift Classification Advisor, Shift Dose Assessor and Core/Thermal Hydraulics Engineer. Noto that old TS (pro Improved TS) Table 6.2 1, whioh implemented tho requirements of NUREG 0737. "Clarification of TMI /\ction Plan Requirements," did not require an STA on shift when both units 'Nore in MODE 6, 6, or defueled. Table 16.13 4 1 is more restricti¥o in that it requires an ST/\ on shift at all times.

2 SROs (active SRO) - Required by 10 CFR 50.54(m)(2)(i). Per TS 5.2.2b and 10 CFR 50.54(m}(2)(iii), at least 1 SRO must be in the control room.

3 ROs - Required by 10 CFR 50.54(m)(2)(i).

§a NLOs AOs - ~Required by TS 5.2.2a and 2 required by tho Fire Protection Program and SLC 16.13-1, Fire Brigade.and Section B, Table B 1a of tho Emergency Rian and implemented via OMP.

2 NLOs Required by tho f'ire Protection Program and implemented via AD and OMP.

1 Shift Communicator - Required by the Fleet Common Emergency Plan.

This position is designated to perform off-site communications during the first 75 minutes following Emergency Class Declaration with no collateral duties.

Any off-site communicator qualified individual may be credited towards fulfilling the ERO requirement.

Fire Brigade Loader - Required by SLC 16.13-1, "Fire Brigade."the Gata1Nba Facility Operating Licensee and Fire Proteotion Program and implemented via AD and OMP. Tho individual fulfilling this position shall be a SRO, RO, or other designated personnel (NhGAO) who is qualified to be a fire brigade leader. This individual functions as the fire brigade leader and is not available for other activities when directing the fire brigade. No regulations explicitly specify that the fire brigade leader be a SRO or RO. However, the fire brigade leader shall have sufficient training in or knowledge of plant safety related systems to understand the effects of a fire and fire suppression systems on safe shutdown capability.

Catawba Units 1 and 2 16.13-4-4 Revision ~

Minimum Station Staffing Requirements 16.13-4 4 Fire Brigade Members - Required by SLC 16.13-1, "Fire Brigade" 1 Chemistry Technician (ERO) Required by NEI 12-01 Phase 2 Extended Loss of AC Power (ELAP) ERO Staffing Analysis Report.Sootion B, Tabla B 1a of tho Emorgonoy Plan. Any technician who is qualified may be credited towards fulfilling the ERO requirement.

BASES (oontinued) 2 Radiation Protection Qualified Individuals (ERO) - Required by Section B, Table B-1a of the Emergency Plan. 1 Radiation Protection Technician is required by TS 5.2.2d and may be counted towards fulfilling the ERO requirement. Any RP Qualified Individual may be credited towards fulfilling the ERO requirement. In the event of a fire, the RP -Qualified Individual will respond to the fire for radiological monitoring purposes until directed otherwise.

1 Dose Assessment Qualified Individual (ERO) Required by Sootion B, Table B 1a of tho Emorgonoy Plan. This position is designated to perform Off Sito Dose Assessment during tho first 76 minutes following Emergonoy Class Deolaration with no oollatoral duties. Any Dose Assessment Qualified Individual may be oroditod to1.-.1ards fulfilling tho ERO requirement.

1 Mechanical Maintenance Technician (ERO) Required by NEI 12-01 Phase 2 Extended Loss of AC Power (ELAP) ERO Staffing Analysis Report.Seotion B, Table B 1a of the Emorgonoy Plan. Any toohnioian who is fire brigade qualified may be credited to 111ards fulfilling tho ERO requirement and tho fire brigade requirement. In the event of a fire, tho toohnioian will respond to tho fire until dirootod othoFY,'iso.

2 Instrumentation and Electrical Technicians (ERO) Required by NEI 12-01 Phase 2 Extended Loss of AC Power (ELAP) ERO Staffing Analysis Report.

Section B, Table 8 1a of tho Emergency Plan. Any technician 'Nho is fire brigade qualified may be credited towards fulfilling tho ERO requirement and tho fire brigade requirement. In the event of a fire, tho technician will respond to tho fire until direotod othorv,1iso.

2 MERT (ERO) Required by AD-SY-ALL-0280, Medical Emergency Response Team (MERT) and Technical Rescue Programs.Section B, Table B 1a of tho Emergonoy Plan. Any toohnioian who is qualified may be credited towards fulfilling tho ERO requirement. In tho 0'1ent of a fire, tho technician will respond to tho fire for soourity purposes until dirootod othon'i'iso.

Catawba Units 1 and 2 16.13-4-5 Revision ~

Minimum Station Staffing Requirements 16.13-4 Minimum station staffing totals for the SRO and RO positions in Table 16.13-4-1 are a function of the number of units in MODES 1-4. The totals for the remaining positions in Table 16.13-4-1 are not a function of the operational MODES of the units. -

10 CFR 50.54(m)(2)(i) requires 2 active SROs when both units are in MODES 1-4, 2 active SROs when one unit is in MODES 1-4, and 1 active SRO when no units are in MODES 1-4.

10 CFR 50.54(m)(2)(i) requires 3 ROs when both units are in MODES 1-4, 3 ROs when one unit is in MODES 1-4, and 2 ROs when no units are in MODES 1-4.

BASES (continued)

The primary purpose of the Fire Protection Program is to minimize both the probability and consequence of postulated fires. Despite designed active and passive fire protection systems installed throughout the plant, a property trained and equipped fire brigade organization of at least 5 members is required to provide immediate response to fires that may occur at the site.

The fire brigade requirement is mot by using personnel from Operations and SPOC. 3 personnel from Operations are required (inoluding the fire brigade loader) and the other 2 personnel are from SPOC.

The 2-hour REMEDIAL ACTION for restoring minimum station staffing levels is consistent with TS 5.2.2c and 5.2.2d, which allow 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> to accommodate unexpected absence of on-duty shift crew members provided immediate action is taken to restore the shift crew composition to within the minimum requirements.

REFERENCES 1. Catawba Facility Operating Licenses for Units 1 and 2, NPF-35 and NPF-52.

2. . Catawba TS 5.2.2.
3. 10 CFR 50.54(m).
4. OMP 1-10, "Shift Manning and Overtime Requirements."
5. AD-TQ-ALL-0086, "Fire Brigade Training."
6. CNS-1465.00-00-0006, "Plant Design Basis Specification for Fire Protection."

Catawba Units 1 and 2 16.13-4-6 Revision ~

Minimum Station Staffing Requirement s 16.13-4

7. EP-ALL-EPLAN, "Duke Energy Common Emergency Plan,"

Rev. O

7. Catm'lba Emergency Plan.
8. SLC 16.13-1, "Fire Brigade."
9. Catawba Nuclear Station 10 CFR 50.48(c) Fire Protection Safety Evaluation (SE).
10.
  • John Stang, Senior Project Manager Offioe of Nuclear Reactor Regulation, lotter to Mr. Michael R Glover dated July 29, 2011, Emergency Plan Safety Evaluation. (ML11158A209).
10. Letter dated 8/26/2021 from Andrew Hon (NRC) to Steve Snider (Duke),

Subject:

Catawba Nuclear Station, Units 1 and 2; McGuire Nuclear Station, Units 1 and 2; Oconee Nuclear Station, Units 1, 2, and 3; Brunswick Steam Electric Plant, Units 1 and 2, Shearon Harris Nuclear Plant, Unit 1; and H. B.

Robinson Steam Electric Plant, Unit No. 2 - Issuance of Amendments for Common Emergency Plan Consistent with NUREG-0654, Revision 2 (EPID L-2020-LLA-0198} ADAMS Accession No. ML21155A213.

11. EP-CNS-EPLAN-ANNEX, "Duke Energy Catawba Eflaff:YQlergency Plan Annex," Rev. O Catawba Units 1 and 2 16.13-4-7 Revision ~