CHAPTER 11 WASTE PROCESSING AND RADIATION PROTECTION TABLE OF CONTENTS PAGE CALVERT CLIFFS UFSAR 11-i Rev. 51 11.0 WASTE PROCESSING AND RADIATION PROTECTION 11.1-1 11.1 WASTE PROCESSING 11.1-1 11.1.1 DESIGN BASIS 11.1-1 11.1.2 WASTE PROCESSING SYSTEMS 11.1-1 11.1.2.1 Liquid Waste Processing Systems 11.1-1 11.1.2.2 Gaseous Waste Processing System 11.1-8 11.1.2.3 Solid Waste Processing System 11.1-11 11.1.2.4 Materials Processing Facility 11.1-12 11.1.2.5 Interim Resin Storage Facility 11.1-13 11.1.2.6 West Road Cage 11.1-13 11.1.2.7 Original Steam Generator Storage Facility 11.1-13 11.1.3 MONITORING INSTRUMENTATION 11.1-14 11.1.4 TESTS AND INSPECTIONS 11.1-14 11.
1.5 CONCLUSION
S 11.1-15 11.2 RADIATION PROTECTION AND MONITORING 11.2-1 11.2.1 DESIGN BASIS 11.2-1 11.2.2 SHIELDING DESIGN AND EVALUATION 11.2-1 11.2.2.1 Primary Shielding 11.2-1 11.2.2.2 Secondary Shielding 11.2-2 11.2.2.3 Containment Shielding 11.2-2 11.2.2.4 Fuel Handling Shielding 11.2-2 11.2.2.5 Auxiliary Building Shielding 11.2-3 11.2.3 RADIATION MONITORING 11.2-3 11.2.3.1 General 11.2-3 11.2.3.2 Digital Processing Radiation Monitors 11.2-5 11.2.3.3 Process and Effluent Radiation Monitoring 11.2-5 11.2.3.4 Area Radiation Monitoring 11.2-8 11.2.3.5 Radiological Environmental Monitoring 11.2-9 11.3 RADIATION SAFETY 11.3-1 11.3.1 GENERAL 11.3-1 11.3.2 ACCESS CONTROL 11.3-1 11.3.3 PERSONNEL PROTECTIVE AND MONITORING EQUIPMENT 11.3-1 11.3.3.1 Protective Equipment 11.3-1 11.3.3.2 Personnel Monitoring Program 11.3-1 11.3.4 RADIATION SAFETY FACILITIES 11.3-3 11.3.4.1 Change Room and Decontamination Facilities 11.3-3 11.3.4.2 Health Physics Laboratory Facilities 11.3-3 11.3.4.3 Health Physics Instrumentation (Excluding Process and Area Monitoring Systems) 11.3-3
CHAPTER 11 WASTE PROCESSING AND RADIATION PROTECTION TABLE OF CONTENTS PAGE CALVERT CLIFFS UFSAR 11-ii Rev. 51 11.4 RADIOACTIVE MATERIALS SAFETY 11.4-1 11.4.1 MATERIALS SAFETY PROGRAM 11.4-1 11.4.2 SEALED SOURCE CONTAMINATION 11.4-1 11.4.3 FACILITIES AND EQUIPMENT 11.4-1 11.4.4 PERSONNEL AND PROCEDURES 11.4-1 11.4.5 REQUIRED MATERIALS 11.4-2
CHAPTER 11 WASTE PROCESSING AND RADIATION PROTECTION LIST OF TABLES TITLE PAGE CALVERT CLIFFS UFSAR 11-iii Rev. 51 11-1 WASTE PROCESSING SYSTEMS COMPONENT DESCRIPTION 11.1-16 11-2 PREOPERATIONAL DESIGN ESTIMATES OF LIQUID EFFLUENT CONCENTRATIONS 11.1-21 11-3 PREOPERATIONAL DESIGN ESTIMATES OF TOTAL ANNUAL RADIOLOGICAL IMPACT 11.1-22 11-4 RADIOACTIVE WASTE PROCESSING SYSTEM SOURCES 11.1-23 11-5 PREOPERATIONAL DESIGN ESTIMATES OF RADIOACTIVITY CONCENTRATIONS IN REACTOR COOLANT AND REACTOR COOLANT WASTE PROCESSING SYSTEM EFFLUENTS 11.1-24 11-6 PREOPERATIONAL DESIGN ESTIMATES OF MISCELLANEOUS WASTE PROCESSING SYSTEM EFFLUENTS 11.1-25 11-7 PREOPERATIONAL DESIGN ESTIMATES OF TOTAL ANNUAL LIQUID RELEASE VIA TURBINE BUILDING DRAINS 11.1-26 11-8 PREOPERATIONAL DESIGN ESTIMATES OF ANNUAL DISCHARGES 11.1-27 11-9 PREOPERATIONAL DESIGN ESTIMATES OF TOTAL PLANT GASEOUS EFFLUENTS 11.1-31 11-10 PROCESS AND EFFLUENT RADIATION MONITORS 11.1-32 11-11 AREA RADIATION MONITORS 11.2-10
CHAPTER 11 WASTE PROCESSING AND RADIATION PROTECTION LIST OF FIGURES FIGURE CALVERT CLIFFS UFSAR 11-iv Rev. 51 11-1 REACTOR COOLANT WASTE PROCESSING 11-2 WASTE GAS AND MISCELLANEOUS WASTE PROCESSING 11-3A SHIELDING ARRANGEMENTS 11-3B 11-3C 11-4 sh 1 RADIATION MONITORING SYSTEM 11-4 sh 2 11-5 REACTOR CAVITY SEAL 11-6 NEUTRON SHIELDING SECTION, UNITS 1 AND 2 11-7 POST-ACCIDENT RADIATION DOSES - AUXILIARY BUILDING PLAN AT ELEVATION (-)10'0" AND (-)15'0" 11-8 POST-ACCIDENT RADIATION DOSES - AUXILIARY BUILDING PLAN AT ELEVATION 5' 11-9 POST-ACCIDENT RADIATION DOSES - AUXILIARY BUILDING PLAN AT EL. 27'0" 11-10 POST-ACCIDENT RADIATION DOSES - AUXILIARY BUILDING PLAN AT ELEVATION 45'0" 11-11 POST-ACCIDENT RADIATION DOSES - AUXILIARY BUILDING PLAN AT ELEVATION 69'0"
CHAPTER 11 WASTE PROCESSING AND RADIATION PROTECTION LIST OF ACRONYMS CALVERT CLIFFS UFSAR 11-v Rev. 51 ALARA As Low As Reasonably Achievable ALPS Advanced Liquid Processing System ASME American Society of Mechanical Engineers ASTM American Society for Testing and Materials CCNPP Calvert Cliffs Nuclear Power Plant, Inc.
CVCS Chemical and Volume Control System DAW Dry Active Waste DLR Dosimeter of Legal Record DRD Direct-Reading Dosimeter ECCS Emergency Core Cooling System ED Electronic Dosimeter GL Generic Letter GM Geiger Mueller HEPA High Efficiency Particulate Air LOCA Loss-of-Coolant Accident MHA Maximum Hypothetical Accident MPF Materials Processing Facility MWIE Miscellaneous Waste Ion Exchanger MWMT Miscellaneous Waste Monitor Tank MWPS Miscellaneous Waste Processing System MWRT Miscellaneous Waste Receiver Tank NEMA National Electrical Manufacturers Association NRC Nuclear Regulatory Commission ODCM Offsite Dose Calculation Manual OSG Original Steam Generator RCA Radiologically Controlled Area RCDT Reactor Coolant Drain Tank RCS Reactor Coolant System RCW Reactor Coolant Waste RCWPS Reactor Coolant Waste Processing System SFP Spent Fuel Pool SRW Service Water SWPS Solid Waste Processing System WGPS Waste Gas Processing System