MONTHYEARNG-20-0090, Certification of Permanent Removal of Fuel from the Reactor Vessel for Duane Arnold Energy Center2020-10-12012 October 2020 Certification of Permanent Removal of Fuel from the Reactor Vessel for Duane Arnold Energy Center Project stage: Request NG-20-0083, Registration of Independent Spent Fuel Installation Storage Casks2020-10-12012 October 2020 Registration of Independent Spent Fuel Installation Storage Casks Project stage: Request L-21-008, License Amendment Request to Approve Pilgrim Nuclear Power Station Independent Spent Fuel Storage Installation Only Emergency Plan2021-02-18018 February 2021 License Amendment Request to Approve Pilgrim Nuclear Power Station Independent Spent Fuel Storage Installation Only Emergency Plan Project stage: Request ML21069A3312021-03-15015 March 2021 Acceptance of Requested Licensing Action Re Independent Spent Fuel Storage Installation Only Emergency Plan Project stage: Acceptance Review L-21-057, Supplemental Information to Update - License Amendment Request to Approve the Pilgrim Nuclear Power Station Independent Fuel Storage Installation Only Emergency Plan2021-05-20020 May 2021 Supplemental Information to Update - License Amendment Request to Approve the Pilgrim Nuclear Power Station Independent Fuel Storage Installation Only Emergency Plan Project stage: Supplement ML21158A1232021-06-24024 June 2021 License Amendment No. 46, Revised License Termination Plan Project stage: Request ML21158A1262021-06-24024 June 2021 Letter - Humboldt Bay Power Plant Unit 3 - Issuance of Amendment No. 46 Re License Termination Plan Project stage: Approval ML21158A1132021-06-28028 June 2021 License Amendment Application - Revision of the License Termination Plan - May 3, 2021 Request for Additional Information Response Clarification Call Project stage: RAI NG-21-0010, License Amendment Request (TSCR-192): Independent Spent Fuel Storage Installation (ISFSI) Emergency Plan and Emergency Action Level Scheme2021-06-28028 June 2021 License Amendment Request (TSCR-192): Independent Spent Fuel Storage Installation (ISFSI) Emergency Plan and Emergency Action Level Scheme Project stage: Request ML21161A1072021-07-0909 July 2021 Request for Additional Information Regarding Pilgrim License Amendment Request ISFSI Only Emergency Plan Project stage: RAI L-21-090, Response to Request for Additional Information (Rai), License Amendment Request to Approve the Pilgrim Nuclear Power Station Independent Fuel Storage Installation Only Emergency Plan2021-07-29029 July 2021 Response to Request for Additional Information (Rai), License Amendment Request to Approve the Pilgrim Nuclear Power Station Independent Fuel Storage Installation Only Emergency Plan Project stage: Response to RAI ML21223A2412021-08-16016 August 2021 Letter to A. Sterdis, HDI, from A. Snyder, NRC - Pilgrim Nuclear Power Station - Request for Additional Information Regarding Pilgrim - License Amendment Request Independent Spent Fuel Storage Installation Only Emergency Plan Project stage: RAI ML21223A2392021-08-16016 August 2021 Request for Additional Information Regarding Pilgrim - License Amendment Request Independent Spent Fuel Storage Installation Only Emergency Plan Project stage: Request ML21223A2422021-08-16016 August 2021 Enclosure - Pilgrim Nuclear Power Station - Request for Additional Information Regarding Pilgrim - License Amendment Request Independent Spent Fuel Storage Installation Only Emergency Plan Project stage: RAI ML21238A2752021-08-26026 August 2021 Clarification Call Regarding RAI License Amendment Request Independent Spent Fuel Storage Installation Only Emergency Plan Project stage: RAI L-21-098, Response to Request for Additional Information (RAI) - License Amendment Request to Approve the Pilgrim Nuclear Power Station Independent Fuel Storage Installation Only Emergency Plan2021-09-0707 September 2021 Response to Request for Additional Information (RAI) - License Amendment Request to Approve the Pilgrim Nuclear Power Station Independent Fuel Storage Installation Only Emergency Plan Project stage: Response to RAI ML21257A3832021-09-15015 September 2021 E-mail from A. Snyder, NRC, to A. Sterdis, Holtec, - Pilgrim Nuclear Power Station - Follow-on Request Re Request for Additional Information 2 Pilgrim - License Amendment Request Independent Spent Fuel Storage Installation Only Emergency Pl Project stage: RAI ML21257A3792021-09-15015 September 2021 Clarification Call 2 Re Request for Additional Information Pilgrim - License Amendment Request Independent Spent Fuel Storage Installation Only Emergency Plan Project stage: Request ML21257A3822021-09-15015 September 2021 Summary of Clarification Cal with Holtec Decommissioning International, Llc. Regarding Second Follow-On Emergency Preparedness Request for Additional Information Project stage: RAI ML21287A6192021-10-14014 October 2021 E-mail from S. Phillips, MEMA, to A. Snyder, NRC, Pilgrim Nuclear Power Station, Commonwealth of Massachusetts Consultation Response to Amendment Review for Emergency Preparedness Project stage: Request ML21265A3032021-10-21021 October 2021 Enclosure 2 - Pilgrim ISFSI Only SER Input Final Project stage: Other ML21251A1622021-10-21021 October 2021 Ioep Amendment No. 257 Project stage: Request ML21251A1732021-10-21021 October 2021 Enclosure 1 - Pilgrim Amendment No. 257 ISFSI Only Emergency Plan Project stage: Other ML21251A1722021-10-21021 October 2021 Issuance of Amendment No. 257 ISFSI Only Emergency Plan Cover Letter Project stage: Approval ML21335A0712021-12-0101 December 2021 Request for Additional Information - Duane Arnold Energy Center ISFSI Only Emergency Plan Project stage: RAI ML21335A0702021-12-0101 December 2021 Cover Letter to B. Coffey from K. Conway - Duane Arnold Energy Center RAI Re License Amendment Request for ISFSI Only Emergency Plan Project stage: RAI ML21335A0662021-12-0101 December 2021 Request for RAI License Amendment Request ISFSI Only EP Project stage: Request ML22357A1002023-03-31031 March 2023 And Prairie Island Nuclear Generating Plant, Units 1 and 2 - Issuance of Amendments Standard Emergency Plan and Consolidated Emergency Operations Facility Project stage: Approval 2021-06-24
[Table View] |
Text
LICENSE AMENDMENT REQUEST RELATED TO PROPOSED EMERGENCY PLAN CHANGES FOR THE HOLTEC DECOMMISSIONING INTERNATIONAL, LLC PILGRIM NUCLEAR POWER STATION DOCKET NO. 50-293 AND 72-1044 By application dated February 18, 2021 (Agencywide Documents Access and Management System [ADAMS] Accession No. ML21049A192), as supplemented by the letters dated May 20, 2021 and July 29, 2021 (ADAMS Accession Nos. ML21140A045 and ML21140A045, respectively), Holtec Decommissioning International, LLC (HDI) requested approval by the U.S. Nuclear Regulatory Commission (NRC) of the proposed Pilgrim Nuclear Power Station (PNPS) Independent Spent Fuel Storage Installation Facility (ISFSI) Only Emergency Plan (IOEP) to support the planned off-load of the PNPS spent fuel pool and transfer of the spent fuel to the ISFSI.
The following are clarifications to the responses provided for the requests for additional information (RAIs). Timely and accurate response to these draft clarifications is requested.
RAI-1
Previous RAI Request: Please clarify that American Medical Response provides transportation for contaminated injured personnel.
HDI (PNPS) response:
Brewster Ambulance Service is currently under contract with the town of Plymouth to provide medical transportation service to the Plymouth area. PNPS has confirmed that Brewster Ambulance Service is capable of transporting contaminated injured personnel.
American Medical Response no longer provides this service to the Plymouth area.
DPP-PIL-EP-001 (IOEP), Section 2.1 Overview of ISFSI Emergency Plan on page 6 has been changed as follows:
Emergency services are provided by local, public, and private entities.
Fire support services are provided by the Plymouth Fire Department; law enforcement support services are provided by local, Commonwealth, and Federal law enforcement authorities, as appropriate; ambulance services are provided by Brewster Ambulance Service; and medical services are provided by Beth Israel Deaconess Medical Center and Morton Hospital.
Issue:
However, it is not clear to the NRC staff that there is a letter of agreement with the Brewster Ambulance Service.
Request:
Please clarify if there is a letter of agreement with the Brewster Ambulance Service and if it specifically states that they would provide transportation of injured personnel for PNPS, including contaminated injured personnel. If this agreement is provided through a contract with the town of Plymouth, please provide documentation that specifically states the Brewster Ambulance Service would provide transportation of injured personnel for PNPS, including contaminated injured personnel.
RAI-2
Previous RAI Request: Please clarify how the Plymouth Township will be notified for an emergency at the PNPS ISFSI.
HDI (PNPS) response:
Procedures have been established for the prompt notification to MEMA [Massachusetts Emergency Management Agency] and the Town of Plymouth in the event of an emergency declaration. PNPS Procedure EP-IP-100, Emergency Assessment and Response, Attachment 9.2 Event Notification Checklist provides the contact number for the Town of Plymouth that would be used by the Emergency Director to notify the town of an event at the Station.
Issue:
However, the sections of the proposed IOEP identified previously in the RAI have not been revised in response to the RAI.
Request:
Please revise the proposed IOEP as appropriate.
RAI-5
Previous RAI Request: Please clarify how onsite announcements are made.
HDI (PNPS) response:
Procedures have been established for the prompt notification of ISFSI personnel in the event of an emergency declaration. Announcements, are made via security radios utilizing PNPS Procedure EP-IP-100, Emergency Assessment and Response,.2 Event Notification Checklist.
Issue:
However, it is not clear to the NRC staff how personnel (public, as well as workers) in the ISFSI Controlled Area as well as the decommissioning reactor site located within the Owner Controlled Area (or within the site boundary) would be notified of an emergency declaration or any potential protective actions.
Request:
Please clarify how onsite announcements are made to personnel without security radios in the ISFSI Controlled Area, as well as the decommissioning reactor site located within the Owner Controlled Area of an emergency declaration or any potential protective actions.
RAI-6
Previous RAI Request: Please clarify if weekly testing of the commercial telephone system is required.
HDI (PNPS) response:
At the ISFSI, testing of both the portable radios and commercial telephone system is done by Security on a more frequent basis in accordance with Security procedures, therefore weekly testing of the commercial telephone system is not required.
Issue:
However, Section 10.0, Table 10-1 Communication Systems, of Enclosure 1, Attachment 1, has not been revised and provides the testing frequency for the commercial telephone system as weekly.
Request:
Please revise the proposed IOEP as appropriate.
New Clarification RAI discussed in the August 11, 2021 call.
Issue:
Table 1, Emergency Plan Initiating Conditions Being Deleted, of Section 3.1, Elimination of SFP Initiating Conditions and EALs, of the February 18, 2021 application provides, PD-HU1 Confirmed SECURITY CONDITION or threat (1 or 2 or 3) at the Independent Spent Fuel Storage Installation (ISFSI)
However, Table PD-1: Recognition Category PD and E Initiating Condition Matrix, in the, ISFSI Only Emergency Action Levels (EALs) and Technical Bases, of the February 18, 2021 application, as well as the May 20, 2021 supplement provides, PD-HU1 Confirmed SECURITY CONDITION or threat.
Request:
Please indicate what version of PD-HU1 is accurate and is to be reflected in the approval.