ML21209A390
| ML21209A390 | |
| Person / Time | |
|---|---|
| Site: | Summer |
| Issue date: | 04/30/2021 |
| From: | Dominion Energy South Carolina |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML21209A581 | List:
|
| References | |
| 21-167 | |
| Download: ML21209A390 (1) | |
Text
RN 18-045 January 2019 14 13 SYSTEM DATA rn:)
GPM PSIG *
"F BY REMARKS 2
9000 50 95 NORMAL 7700 50 130 POST ACCID A
3 1000 50 95 NORMAL 820 50 116 POST ACCID 4
1000 to 45 124 NORMAL 600 500 45 130 POST ACCID 17 0.032 50 100
- APPROX.
B C
D E
LOOP "B' J - 9
RNm-8 19 REQ'Dl F
G H
J HYDROSTATIC TEST TEMP. 60" 18 50 100 N/A N/A 16 16 130 20 135
<1%
25 JPM 15 65 130 65 135
<1 1/.
82 JPM 10 12 5 95 165 95
<1%
210 RJS 9
16 150 20 150
( 1%
25 ccs 8
16 9 5 20 214
( 1%
25 ccs 7
16 124 20 130 25 WTW LRC K
6 65 124 6 5 130 8 2 WTW LRC 5
65 9 5 65 9 5 82 ccs NOTE 3 PSIG F
PSIG F
DURATION HYDRC BY CHO REMARK NORMAL UPSET DESI GN DATA 12 11 10 9
8 7
6 5
4 3
- ------------------------'-'16'---'-------------------------------- ---------------------'1-"6-' -----l -222, SHT.4 X
l()
IS) l()
N 16" 20'x16" 20" 24 "x20" COUPLING
~
24" 30'x24'
~
8' XGK00018 (NOTE 121 NO TE 12 VENT '\\_
1/2" 1/4/F= 1' -0,,
0' 5'
10' 15' HVAC CHIL LER B CONTR OL IGAI DWG B-208 109 SHT VU02 I
I I_~ v M
ZS 6'
/RNn - 55 3126B-SW 6"
~
3122B - SW H~CD L~I ROh-1 IPX4485A-HR-SW\\
ROh-1 13123-SW 0-4
-841 vu CDl I
I 0- 4
%)Tse ROh-1 FT L CD~ j L VENl
- 841 VU PX IFT4491-HR-SW 4491
-- 1~1 TW 4503 3/4' 44858 TE 4504 VE~
',_L---1'~1-----'
! (FB\\.0.
1' 5
XHX VU 3/4!I 3/4",------illfllllt------1 CHILLED WATER
- ,---~c----j--
D-302 - 841 LDC0-¥
~
ROh-1 --------~
13122-SW 20' STATION DRAINAGE E - 911 - 106 LOC H-9 26 3/4 -------~-c HVAC SYSTEM MECHANICAL I WATER CHILLER CONO "B' llli:)
ROh-1 IPX4485B-HR - SW TI 4505
\\~
~o 1'
3/4"x1/2".n!-__.Y '-~R~-h_
!FT 4491-LR-SW ROh-3 \\
3149-SW ROh-1 J-13
-611 cc ROh-1 4'
SET AT 3/4" 70 PSIG l"
151X 11:)
RNi - l 0
--.--3144B-SW v7 ROh-1
_.A,
'>3t'13,'"igmgc--sr1w-:;--3:c3/4-*' *v IPX4515B-HR-SW
!FT 4490-HR-SW 1"x3/4" ROh-1 IPX4515A-HR-SW COMPONENT COOLING ~
~
75 HEAT EXCHANGER "B' ~
~
31258-SW SAMPL E SCE&G 3180B-SW STATION DRAI NAGE E-911-106 LOC.H-11 X -
l() -' -
RDh-1 13125-SW TE FT RDh-1 151X 152 3
(/)
l()
m
.C N z-Ct: M 3"
RN -14 3123B-SW
~
6' RN -16 31278-SW 15 16 MRF-21746 3195B-SW ROh-1 PX 4506 2
~~\\58A-r5w--'-~-t:t 3/4" ECR - 50933B,
6
_ I 7
16 8
24'x20" 7 9 COUPLING RNm - 6 20' 8
9 16' 20 "x16" 30"x2 4" G-3
-222, SHT. 4 I PX4506A-HR-SW~
,----------'-- ---~
8' RNj -1 0 t
(qD 64 PSIG
~
XPS0254B I
---rl
' i,_ ____ __:Ef33 >----------f,0-----"----'--------j f-----------l 1
<9Tsc
~~
1 1
COUPLING RNm-7 C-2 I lMS 094 ~ 17 SHT.l LOCAL CHEMICAL ~
ADOIT[ON SKID 18 20' RN - 15 3104B-SW ROp-49 31318-SW TW 1'
>-------i 4507 ROi-22 3119B-SW 1/2' QUICK CONNEC T 3/4' ~~
i:J--cJ~o*_L_J
~
\\
ECR50863 43123B-SW BY VENDOR 153X 8"
DIESEL GENERATOR "B"COOLER ---~
ZS ROl - 39
\\
3120B - SW l '
OSP-661 TI XHE - 17B-DG 3/4" 3/4" x1/2' 4509 I Q)
£j)-
ZS
~
_l~
<e<
~
LO ROh-1
!FT 4492-HR-SW
!FT 4492-LR-SW ROh-1 I PX4506B - HR-SW ED
[ssJ
- T I
CO2 DG ' B' HI LUBE OIL /HI WATER
- JACKET TEMPERATURE LOGIC SEE GAi OWG 0- 802- 014, SHT 5 17sx +sP-12,4 H-3 4*
I f---f I (231 SHT. 31 I"
XPS-147B-SW
]!DRAI N!
ROb-1 13127-SW RETURN TO S.W, POND PEN DING/HOLD CHG Use with reference;,.
ECR: 5D585 DATE: 9-/5 * /0 INITIALS: TME 5
10/22/18 JMR 4
3/4/G RHM 3
9/4/2012 TGB 2
7/28/11 JTS 4/J0/11 RHM 0
1/6/09 JNC NO.
DATE BY I u
(/).
~en 18 RE 'DI ROi - 21 31308-SW NOTE 11 COUPLING RNm-7 13 REO'DI ESSENTIAL REVISED PER ECR-50933B REVISED PER ECR-50863 REVISED PER ECR-505850 REVISED ER ECR-50585 REVISED PER ECR-5D695 REVISED PER ECR-71215 REVISION 2
- NOTES,
- l. ALL PIPING TO BE LINE SPEC 152N.
EXCEPT AS NOTED,
- 3. TEMP CORRESPONDI NG TO PERTINENT HEAT EXCHANGER OUTLET.
- 5. ALL STATUS LIGHT INDICATE BOTH OPEN AND CLOSED POSITIONS.
- 6.
- DENOTES MI SSION DUO CHECK OR EQUAL.
- 9. RECORDER SHARED WITH REACTOR BLOG SPRAY PUMP FLOW INSTRUMENTATION.
- 11. XVC03130 A/B MAY NOT PROVIDE ADEQUATE I SOLATION FDR USE AS A BOUNDARY DURING SYSTEM DRAINING.
REFERENCE NCN5063 ISP. '4.
- 12. 8' SW-TO-EF X-CDNNECT PI PING FROM 24' HEADER TO INLET FLANGE OF TEE I S L INED WITH CURED-IN-PLACE PIPING TO ELIMINATE CORROSION AND MI C BUILD-UP.
!SEE TR04330-005 & ECR506951 WEKO SEALS INSTALLED INTERNALLY TO PIPING TO SEAL ENDS OF CURED-IN-PLACE PIPELI NER.
13, Bl6.5 150
- 14. 8' SW-TO-EF X-CONNECT PIPING FROM OUTLET FLANGE OF TEE TO INLET OF XVG01037B-EF IS COATED WITH PLASTOCOR TO ELIMINATE CORROSION AND MIC BUILD - UP.
15, XPS - 0235 IS A 3/4j" SST SPACER RING INSTALLED BY ECR-50695 THIS IS A NUCLEAR SAFETY RELATED DOCUMENT. NO DEVI ATION SHALL BE I NITIATED OR PERFORMED WITHOUT PRIOR DOCUMENTATION AND WRIT TEN APPROVAL FSAR FIGURE 9.2-2 SH.3 SOUTH CAROLINA ELECTRIC & GAS COMPANY VIRGIL C. SUMMER NUCLEAR STATJON PIPING SYSTEM FLOW DIAGRAM SERVICE WATER COOLING AME WTW 8 - TR-'"JN OUTSIDE RB u
DESIGN ENGINEERING MGR SP SCEM; MGR RS A SCN-IA COl,IP/INY V. C. SUMMER NUCLEAR STATION JENKINSVILLE, S. C.
MADE CHECKED LE APPROVN...
MGR RS
- 2.
3, MGR WTW JNC PAH MGC PAH MGC =
HO SCALE D-302-222 3
5 LE CKO.BY APPROVAL DRAW ING i'a.J~BER SHT. NUMBER REV A
B C
D E
F G
H J
K