ML21130A286

From kanterella
Jump to navigation Jump to search
0 to Updated Final Safety Analysis Report, Drawing 4259, Sheet 1, Containment Vessel Penetration Location
ML21130A286
Person / Time
Site: Cooper 
Issue date: 04/21/2021
From:
Nebraska Public Power District (NPPD)
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21130A114 List: ... further results
References
NLS2021013
Download: ML21130A286 (1)


Text

V>

z 0 !

0 z 180' I

X-33

\\ 6'.

2 SPACES 0 1'-6"=3'-0" EL. 905' -0" (REF.)

(OUTSIDE FACE OF CONCRETE SHEILD WALL)

\\~------~EL. 900'-11" (TYP.)

EL. 911'-6" X-30 270" X-34 SECTION 1 -1 X-31 51' SEE NOTE 4

/

... /

/

/

/

EL. 898'-9" I 0' I

SECTION 2-2 SEE NOTE 4 180' X-29

    • ~.

SECTION SEE NOTE 4 225' EL. 946'-Q" 270' 3-3 TOP OF STEEL EL. 901'-3" X-7A X-9A EL 904'-10" X-7B 180' SECTION SEE NOTE 4 180' X-8 X-7C X-9B X-7D 14'-8" 14'-Q" 10'-Q" 9'-0" EL. 908'-4" EL. 913'-7" X-12 EL. 907'-o*

6 SPACES @

3'-6"=21'-Q" X-13A EL. 912'-2 7/16" 0"

4-4 SECTION 5-5

'---------------------------7 X-11 EL. 906'-6" X-13B X-49 1*-a*

1'-10"/ /

X-100D_/_/

X-100C 2 SPACES 0 EL. 920' -1 o*

X-44 120' X-43 EL. 920'-6" EL. 920'-10" X-47 180' X-10 X-46

/

'o.

EL 919'-1"

'o.

X-45 X-40C X-40D SEE NOTE 4 2'-0"=4'-o"x-1oos EL. 920'-10 1/2" EL. 922'-6'"

-- 270' X-4 180' 165' 150' 135' 120' 105' 90' I -----

165' 150' 135' 120' 105' 90' 75' 60' 45' 30' 15' STRETCHOUT VIEW OF i

DRYWELL DRYWELL HEAD o*

X-101C X-1018 X-101A SECTION SEE NOTE 4 345' 330' 315' 300' 285' 270' 255' 240' 225' 210' 195' 180' O'

X-105A X-1058 X-105C 6-6 EL. 919'-5" EL. 919' -5" EL. 977'-2 3/4" OF SHEAR LUG

-<<-(!_-EL. 961'-10-3/_4_"

SPRAY HEADER

~-EL. 938'-=-o*

I X-1 04E \\

4 SPACES Cl 1'-5"=5'-8" X-100A o*

').

X-1040 X-106 SECTION 7-7 SEE NOTE 4 3 SPACES @

3'-0"=6'-0" X-101F X-105D EL. 920'-10"

___ __/

EL. 936'-10" 345' 330' 315' 300' 285' 270' 255' o*

OUTSIDE OF DRYWELL 240' 225' 21 o*

195' 180' FOR PREVIOUS REVISIONS, SEE SUPERSEDED CARDS.

REVISIONS BY N.P.P.D.

NO.

REVISIONS N10 REDRAWN PER CR96-0160 DCN 97-0094 OFT CK* APP DATE SPB JEH JRF 1-31-9 EL. 931'-10" EL. 926'-10"

-~-

EL. 906'-10"

-~

EL. 901'-10" EL. 896'-10" EL. 879'-4" NOTES:

1. FOR PENETRATION, TYPE, NOTES AND REFERENCE DWGS. SEE DWG. #4262 (FOR REF. ONLY).
2. PENETRATIONS ARE HORIZONTAL IN ELEVATION AND RADIAL IN PLAN UNLESS OTHERWISE NOTED.
3. ELEVATIONS GIVEN IN SECTIONS ARE AT INSIDE FACE OF DRYWELL SHELL, UNLESS OTHERWISE NOTED.
4. FOR ORIENTATION TO BUILDING SEE DWG. #4260 SHEET 2.
5. FOR SECTION NOT SHOWN ON THIS DWG. SEE DWG #4262 (FOR REF. ONLY).
6. ALL PENETRATION ARE SHOWN IN THEIR APPROXIMATE LOCATIONS.

SIGNIFICANT NUIIIBER GROUP THIS DRAWING IS NOT TO SCALE 4

DRAWN CHEa<ED APPROVED DATE DATE DATE CONTAINMENT VESSEL PENETRATION LOCATION SHEET 1 SEE SUPERSEDED O\\RDS FILMED 454004628 AS BUILT CADD DRAWING DO NOT REVISE MANUALLY BURNS & ROE

<O...

N -

0 0

~u REVISION C

4259 N1O 0

~