TO 480V SWGR BUS 1F
< CD r2r2
(/) (/)
SA 1AL f 60A u u "
TO 480V SWGR BUS 1F
<( CD
~i:t Ul 11>
1 A 1C 15A 10 8 "
G1 TO u u 480V SWGR BUS 1G 5A 1AL T
60A 0
60A 81
~
<I "
50A G1
~ ii,
,-: ON oNI oo N<<>
la 0.,,
~
1E G1 1AR f 30A
~
30A G1 G1 2
18 1AR f
1F G1 30A 30A G1 G1 1C 3
(
3/4 3/4 TO 480V SWGR BUS 1G 8 "
z 7A 1A w
~
18 1.5 G1 1C 20 z<
t::-1 t:,.
z"'
- , I u~
'- I 1D G1 18 2A 100A
~~
0..,
c:: m w
C, -
G1 G1 1E 50 l
z-~t
~,
c."'
- , I 1CL f 60A I
"' 5 u
60A G1
~ -" "
I "
5 u
1CR 28 5D 2C 1EL G1 4
30A 81 2A 30A 10
~¥
,_ ii!
"' I a! "-
I W x
I 100 G1 DIV I 460V 3¢ 3W MCC M 800A BUS (REACTOR BUILDING UPPER EL 958' -3")
MCC COMPARTMENT UNIT # -
1YPICAL 30A 30A G1 10 3A 3
G1
~~
N..,
c:: m w
C, -
G1 38L
- a.
<I "
1E 15A 7.5 50A G1
~ iii G1 38R 48R OON I")~ I
'-'-~-'oo rvv-," N <<>
la O"'
~
1FL f 30A u a.
15A G1 1FR 3C Q. 0 G1 4A 2AL f 60A 50A G1
~ ii, OON l">~I oo r.'V"""' N <<>
la 0.,,
~
48L 2AR f 30A 30A G1 gi
<I "
~ ii,
,n ON
~~I oo
,VV-," N <<>
la 0.,,
J z C.
4C
~
}200A f 60A 200A 60A 3 G1 z V,
§k
'"U
~
- a. "
J,n o-u, DIV II G1 30 28 4D 3
460V 3¢ 3W MCC U 600A BUS G1 2CL JQ o-u, z SAL ill
- a.
<I "
(REACTOR BUILDING UPPER EL 958' -3")
1 ER 2A 2C 3A 3C 4A 4C SCL 60A 60A G1 J~
o"'
ul C.
50A G1 2CR f 60A j'l 0"'
ul "
SAR 60A G1
~ -" "
- f 30A 30A G1 SCR 20 3
200A 100 li' u I
- , I
- ,; b xi 58 5D 3A 38L 100A 3
G1 SC 3
30 G1 G1 6AL f60A
- a. "
60A G1 MCC COMPARTMENT UNIT #
1YPICAL 5FL 5FR f 30A 30A G1 0 ;,
z
~u:
u"'
..,0
"'a.
6AR 1
C. "
C.
f 30A 30A G1 6AL
'---------------------------7 38R f 30A 10A G1
~
<(
~ ~ ;!
V-.IV-.IN ~ -I
~
3C 100
~J
- J I a."-
Q."'
- , I 3
G1 460V 4A 100A 4
G1 4C 200A z
~~
I
- , I
- ,; b xi DIV I 3¢ 3W 1200A 58 G1 MCC BUS SC p
rn' CD " -"'
~i:;:j
- ,; 0
- ,; ::2 w
B 40 G1 50 f 200A N -
200A G1
~ 200A
(~~~R FLOOR)
(RADWASTE BUILDING EL 877'-6")
68 6C 6D 6E 6F 30A 20A G1 G1 G1 G1 7.5 TO 6AR 6BL 6BR 3
7A R
f;j Q. "'
B 40 78 G1 480V SWGR BUS 1G 1A 1C 7C 15A 1D TO 480V SWGR BUS 1F u
u "
18 MCC COMPARTMENT UNIT # -
1YPICAL 7D 7E I
G1 G1 G1 1C 15A 2
8A 1
G1 G1 10 10A
- '§'
zo 88 R
- [j
- a. "'
w B G1 G1 0 w I
~
1E 1F 2AL 2AR 1E 2AL 2AR f 60A 30A DIV I 460V 3¢ 3W MCC N 600A BUS (REACTOR BLDG LOWER EL 931 '-6")
2BL 2BR 2C 2D 2E f 60A T
,aOA 2F 100A 30A 15A 15A 3
BC G1 N
z
~I oo
,VV-," N <<>
la 0.,,
.i:_(..,
z "
~
SEE NOTE 4 2
G1 8D 30 C.
w ilj O Q.
z !cc LL.I w"'"'
0 <(0 ZQ.::,
0..,J uu,v, G1 BE 50A 2
DIV II 15A G1 8F z "
JQ o-u I
- a.
15A G1 G1 60A G1 JQ o-
'-'1 "
9A 460V 3¢ 3W MCC V 600A BUS G1 (REACTOR BUILDING LOWER EL 931 '-6")
2BL 2BR 2C 2D 3AL 9C 1
1A1 7.5 z
~~
°' I ~!
OCD 01 en-G1 9D 81 1A2 3AR z "
100A 1 G1 9E 15A 81 G1 181 G1 9F 10A G1 1
182 MCC COMPARTMENT UNIT # -
1YPICAL 38 3D 3E G1 5D G.,,
5 z
MCC COMPARTMENT UNIT # -
1YPICAL 38L 38R 3C f 30A 15A G1 N
z 30A 30A G1
~ ii, G1
<I "
,n ON
~~I z " (
108 100A CD
.l:
- J I C. "-
c."'
- , I V, -
3F G1 oo
,VV-," N <<>
la 0.,,
~
10C 11A G1 10 z<
~I uu
°' I _...
u"'
WI o:-
G1 3/4 4AL 4AR 3D 118 11C 15A 48 3E 2.5A 2
G1 3/4 3F 60A 20
~J I u
- J I a."-
Q."'
- , I G1 48 15A 2
G1 4C 50A zo G1 J___30A 0_:)
NEW VERTICAL SECTION #12 FURNISHED BY CONTRAcf E69-26, 4D 81 INSTALLED & CONNECTED BY I
CONTRACT E69-17.
~
11D 11E 15A 2
G1 4C 4D 11F G1 G1 4E 12D 81 12A 12C 13A 138 13C 5A 58 SC 5D SE SF 128 70A 3
13D 4
G1 81 1F 28 38 48 SE 6C 6D 6E 6F f 60A f 30A f 60A f 30A f 60A f 30A f 60A f 30A f 60A T 60A f 60A T
30A f 60A f 30A T 30A 2BL 30A 81
}60A *35A 81 2BR
}60A *35A G1 2C G1 4
G1 200A 100 CD z.\\
"- I
~If a."-
Q."'
- , I 100A 3
G1 G1 40 2DL 2DR 2E f 60A 50A f 60A 30A 81
(
30A F
3 w
~
4 3
- , 0 100 lj' CD
,- I
- , I
<( "-
I W
xi G1 3A 1/2 oc"--
..,,a I 0-::, I
~a.(,)
I
,_ u C.
0$1 IU-G1 40 38 4
G1 G1 100 li' 0
,- I
- , I
<( "-
I W
xi 3C G1 G1 0 -
60A 81 3D 15A G1 3/4 10A G1 X
~ ~ ~
__._,.,._,N ~
I
~
&l 3E G1 5
0 60A G1 g
20A 81 1.5 3F
...J ':
...J IO oai 01 ol oz C.
f 100A 100A 81 Zv, 9k WU 4A 48
}
100A f 100A G1 PWR DIST BOX
~
OON l'l ~I oo N <<>
I -e......
0 I<) ~
!l' 30A 30A 81 G1 G1 MCC COMPARTMENT UNIT #
1YPICAL 5CL 5CR 5D 2
50A G1 J:.__o, 0_:)
ZCD 1::-1 z"'
00 i= J_
=>o a, I o-F 2
SE f
f 30A 60A f 100A f 100A 60A G1 15A G1 ffi 0
zw
-w
.., o-u z ow
~~
-u 60A 81 70A G1
~~
,-: ON
"'NI
.. ' oo N <<>
Is O"'
~
MW223 70A G1
~ ~N
>C NI
"< 0 0 N <<>
Is 0..,
...c~
~
= N... --'----~
~ MW256
(
SF 100A 75A 100A 100A G1 6AL 60A G1 J.
o" ul Zv,
§k
..,u z
6AR 60A 60A G1 f J, 30A *30A 68 30A z
~~
°' I ~!
QCD 01 en-G1 100A 4
G1 60 6C G1 2
81 6D 30A G1
~ ii,
,n ON
~~I oo r,,-v-""' N <<>
la 0.,,
2 G1
~
6E 1.5 0
<I ~
6F 50A 2
7CL f 60A 60A G1 VERSIONS/REVISIONS BY NPPD NO.
DESCRIPTION ORDER OFT DATE ENG AY 79 DR-2020-0021 20-001 DLR 6 10 20 JDMADDO G1 7CR z<D
~I uu o: I _...
u"'
.., I o:-
f 30A 0.. 0 N::J 0
<] ~ :::!!
G1 SIGNIFICANT NUIIIBER GROUP G1 t:
z
- c. I W,a<
!;;i:=>.-
"'a. I zx"'
w.., I 0" C.
za.u O=> I uo-G1 15A G1 0
1.5 2
15A 81 25 0 2
20A 81 25 2
G1 7.5 20
- ,~
I u
- J I a."-
Q."'
- , I G1 G1 FUSE LEGEND:
G1-GOULD TYPE TRS FUSE 81-BUSSMAN TYPE FRS FUSE NOTES
- 1. FOR SYMBOL LIST SEE DWG 3070.
- 2. FOR MOTOR CONTROLS &: THEIR OPERATIONAL FUNCTION, SEE RELATED ELEMENTARY DIAGRAMS.
- 3. EACH SOG INCLUDES A GROUND FAULT RELAY, A 480-120V XFMR, A TERMINAL STRIP & TWO FUSES.
THESE DEVICES ARE LOCATED IN A RELAY COMPARTMENT SEPARATE FROM THE STARTER. REFER TO DRAWING 3042, 3253 & THE !TE DRAWING 85870008.
- 4. EQUIPMENT ABANDONED IN PLACE.
NEW VERTICAL SECTION #9 FURNISHED BY CONTRACT E69-26, __ _
INSTALLED &: CONNECTED BY j
CONTRACT E69-17.
7D 1.5
~
~
<D J,
0 z 8 t I
C. C.
- , I IC.-
81 7E f 200A 0
~
~
w I:'
X u u "
5 z
BAL 8AR BBL 8BR
}30A }30A
- 30A *30A G1 G1 f 60A 4
60A G1 8D BE BF COOPER NUCLEAR STATION AUXILIARY ONE LINE DIAGRAM MOTOR CONTROL CENTERS M, N, P, U, V, & W 9AL 9AR 98L 9BR 9CL 9CR 9D 6E f 60A BOA G1 AS
}60A }30A f 30A f JOA
[JsoA CJ20A 20A 81 20A 81 G1 G1 1.5 CD
- a I "
~
o-z I
":J ii!
- a. I
~5
<D"'
- ,w AUGMENTED
~ Ir RW & RADWASTE ~ ~
BLDG VENT u (/)
MONJTORS
~ S:
81 454003880 STATUS: Release BUILT STATUS DATE: 06/10/2020 DS APPROVED: JDMADDO VER: AY REV: 79 SIZE: F DRAWN DR CHEO<ED JAC APPROVED WCF DATE 6-1-94 DATE 11-8-94 DATE 11-11-94 BURNS & ROE -
0 0
~u I----.---~------------;.
FILMED 3005 SH 4
~