ML21130A266
| ML21130A266 | |
| Person / Time | |
|---|---|
| Site: | Cooper |
| Issue date: | 04/21/2021 |
| From: | Nebraska Public Power District (NPPD) |
| To: | Office of Nuclear Reactor Regulation |
| Shared Package | |
| ML21130A114 | List:
|
| References | |
| NLS2021013 | |
| Download: ML21130A266 (1) | |
Text
{{#Wiki_filter:* z 0 ! 0 z '---------------------------7 ~ TRANSMITTER/ STATION SIGNAL COMMON COM HOT 120V AC 60HZ NEUTRAL 22% FLOW LIMIT REACTOR RECIRCULATION PUMP A/B SPEED CONTROLLER CONFIGURATION FUNCTION BLOCKS TYPICAL FOR CONTROLLERS RRFC-SIC-16A/B HLD4 °1 t---~ REGULATED {-------'=----{_l)H ACH/DC+
~0 N ACN/DC-100% FLOW SWITCH #1 EQU[PMENT
!Zjt--~G~R~O~UN~D~~0 CASE/ SAFETY GROUND 22% FLOW LIM IT 39 ,---,r::--------'-'--<lJ,,XMTR+ ,1_5 4D../7l COM >-----<A 01 >--------- HLD1 01t-------------------,B TSW1 ,---------------,SC TSW_ LOGIC: A --,- B I C SEL2 01t--------, SCALER RRFC-MVl-17A/B ,--7 MV/1 I TRAN s M ITTERI I s s I L *>- -~ _J TB-1209 RRFC-SI-1A/B .---7 I 1 1 I <Zl 0 I -' I I L __ _J INDICATOR PERCENT SPEED (ACTUAL) RRFC-SI-2A/B T 9 L _____ j.2:"..q;1+--01,f + 01 >---------------~ SC = LO SC = HI OUTPUT = A OUTPUT = B
t----lR OR R
+ - 19 I 7 ---,__A __ s_c_L_1 _0~1>------~~.::::~ AouT2 ct7=>--"10~!Hi _____ 1:-'1 -l!_L__I_J<Zl 0 I DISCH VALVE OR LOW F.W. FLOW RR-REL-K4A/B (CONTACT OPENS FOR LIMIT) 12 DIN1 QS - OUTPUT "HIGH" NORMAL OPERATING CONDITIONS 45% FLOW RUN BACK _o_s ___ ~- ,_, I I SPEED DEMAND L _J OUTPUT SIGNAL 20-100% INDICATOR PANEL 9-4 PANEL 9-4 PERCENT SPEED DEMAND 45% RUN BACK FEED PUMP TRIP & REACTOR LEVEL LOW RECIRC FLOW RUN BACK 40% FLOW START-UP 100% FLOW HLD2 °1 HLD5 SWITCH #2 ~---IA 01>----------+-~ ~----------------<B TSW2 ,---*--+----------------------------<SC RAMP RATE LIMIT 1 %/sec. OUTPUT SIGNAL CHARACTERIZER ,-c-- ---lFR;-----~+ho,,_..1.17"!._i:.,-:::,-, _____,::,-:::,-,_!..--..::~'m_,.,,,_d t----iX CHR1 OY>--~-----;S AOUT1 I I I I I 2500 I ~-_-_.... --igs ct1or1"~:1:-_+-,----1:-,_-1_;--:-1-wOJ I ~---~ L __ _J -,---<A 01 >--~ SPEED DEMAND OUTPUT SIGNAL 0-100% SCOOP TUBE POSITIONER 13 RR-REL-K49A/B "\\l+ 01-14 DIN2 OS 40% FLOW LIM IT HLD3 o1t--- SWITCH #3 ---;A 01 f----~ (CONTACT OPENS FOR RUN BACK) 5 OUTPUT "HIGH" ,--+--+----------'.:_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::_-::; ~c TSW3 NORMAL OPERATING CONDITIONS T 9 L-----+.'.215~;,[+----m\\ + 01-RRMG-REL-K3A/B 16 - DIN3 OS - ""ll ___ _, LOW VALUE SELECT --i--iA 01 - ~-1-lB SEL1 --,-...,c -R >-----+---IA SPLIM 01 t---+-~ HS>--- LS - SETPOINT LIMIT 20-100% E RLM 1 Rli---- '------'F~L 1-- OUTPUT SIGNAL TO LIMIT COMPARISON A CMP1 °1 -EL REVERSE ACTION LIMIT 16% ,--7 -~c=---~no~y~2~*---------'-I-~m I RDUT1 C l'.Z)-'2"'8---------+-{[) ~D I I LOSS OF SPEED DEMAND SIGNAL OR ANALOG OUT FAILURE OR ON-LINE ERROR L __ _J SCOOP TUBE LOCK OUT CKT. & ALARM ,--7 I~ I I I L __ _J SCOOP TUBE JORDAN CONTROLS ELECTRONIC CONTROL CABIN ET RELAY K 19A/B 2-184-12A/B RELAY K5A/B 2-184-12A/B FIELD BREAKER (CONTACT CLOSED FOR START-UP) START UP RELAY ENERGIZED TD START DE-ENERGIZED DURING RUN OUTPUT "LOW" NORMAL OPERATING CONDITIONS >----jA ~---<B
<-----IC 01 f--~
RESET PERMISSIVE JORDAN CONTROLS ELECTRONIC CONTROL CAB! NET
iR 01 >-----.
>----ITV
;TC SETPT
---<SR ,---!LU LO 5 MANUAL SETPOINT t------lPR PN t-- ,----t-'t------{,!."!J XMTR + ADJUSTMENT
;RV PF>--
I I 20 --<RX LE>--- + OR ---IRY CNt-- (._ ___ ) r:;: -- -- 7 2500 I ""'-i ~' I I 2500 I I - I I POSITION I FEEDBACK L SIGNAL _J SCOOP TUBE POSITIONER
,_......- 18 AIN1 01 >----+--+-----+------------------+--------------+---------------+-+--------
--- -~fl~c~--~~j soocW>--- 1 '-t--------<V NLt-- SCOOP TUBE POSITION 0-100% ET>-- >----1 A NOT2 01 t---lP OST1 RT>-- 01 >--- A NOT3 01 l°"L A B AND1 011-~ OR1 01 1-- -A B -C I.::_ __ RESET LED LED
;X WO>---
---<Y SE>--------+-~ ---IU1
;U2
--<CL ---!EL OPERATOR DISPLAY PERMISSIVE LED'S ANALOG DISPLAY L= LOOP STATUS P= POSITION S= STATION STATUS S= SETPOINT V= OUTPUT NOR1 --,---afcc---;;;no~;i,32LJ RO UT2 C 17)-'3U.1 _ _J nc OUTPUT SIGNAL SCOOP TUBE POSITION DEVIATION SCOOP TUBE RESET PERMISSIVE -c R A1 A 01 >---~ >-------------------------------------------+-----+--IP ALARM A2 - NOT1 ~---10 A3 - M - BLOCK TYPE AOUT_ QUALITY STATUS: OS TRANSITION LO~HI 01 ---<,A LMT1 HS 1-LS CONDITION HI Z OR OPEN CKT MPU CONTROLLER BOARD JUMPERS JUMPER {SHUNT) IP W2 DESCRIPTION ETHERNET//LIL/ MOD BUS JUMPER INSTALLED YES DEV ALARM LIMIT +/-2% RANGE 0-100% NOTE:
- 1. RRFC PUMP SPEED CONTROLLER REQUIREMENTS AND CONFIGURATION DESCRIPTION, CED 2001-0017 ATTACHMENT: F W4 LONWORKS 1/0 BUS WB REAL TIME CLOCK BATTERY YES
- 2. SHUNT INSTALLED ON N/C OF WB DURING STORAGE, YES CONTROLLER BOARD VERSION DEPENDENT (NOTE 2)
FOR PREVIOUS REVISIONS, SEE SUPERSEDED CARDS, REVISIONS BY N.P.P.D. NO. REVISIONS DFT CKD APP DATE N05 CR-CNS-2007-00411CDCN 07-0045 DLR DLR DJB 1 17 07 N06 CED 6010820 cOCN 05-17651 DJB PAM DLR 04 29 08 N07 CED 6010820 fOCN 08-05171 KG KG TJO 5 5 08 SIGNIFICANT NUIIIBER GROUP INSTALLED ON CLK WHEN CONTROLLER INSTALLED IN THE FIELD. 4 COOPER NUCLEAR STATION REACTOR RECIRCULATION CONTROLLER CONFIGURATION DRAWN 1 DATE DLR 8/21/01 CHEa<ED I DATE JDN 3/19/02 APPROVED I DATE KMD 3/19/02 AS BUILT 454244494 CADD DRAWING DO NOT REVISE MANUALLY GENERAL ELECTRIC a, 0 N 0 0 ~u C FILMED REVISION 730E197BB SH 68 N07 0 ~}}