0 to Updated Final Safety Analysis Report, Drawing 921D796, Sheet 1, Functional Control Diagram Area Radiation Monitoring System
ML21130A222
Person / Time
Site: Cooper Entergy icon.png
Issue date: 04/21/2021
From:
Nebraska Public Power District (NPPD)
To:
Office of Nuclear Reactor Regulation
Shared Package
ML21130A114 List: ... further results
References
NLS2021013
Download: ML21130A222 (1)


Text

1 A

B C

D E

F G

H

(/)

z 0

U)

~

J 0:::

ci z

1 RANGE

.01-100 MR/HR

.1-1000 MR/HR 1-10 4 MR/HR 100-10 6 MR/HR (TYPICAL)

AREA RADIATION MONITOR WITH OPTICAL ISOLATOR DRYWELL SENSOR &

CONVERTER (HIGH RANGE)

RE-40A LOCAL TYP (40B)

RAD 2

SENSOR &

CONVERTER RE-2, 11, 12, 14, 16, 17, 20, 21, 22, 23, 28, 29, 30 RE-4, 5, 6, 15, 25, 26, 27 RE-18 RE-1 MONITOR (HIGH RANGE)

PMIS TABLE 5 RM-40A CR TABLE 1 AUXILIARY UNIT RM-AU2, 11, 12, 14, 16, 17, 20, 21, 22, 23, 28, 29, 30 RM-AU4, 5, 6, 15, 25, 26, 27 RM-AU18 RM-AU1 POWER PANEL CPP I

I I

3 INDICATOR &

TRIP UNIT RA-2, 11, 12, 14, 16, 17, 20, 21, 22, 23, 28, 29, 30 RA-4, 5, 6, 15, 25, 26, 27 RA-18 RA-1 4

AI.ARM MODULE AM-2, 11, 12, 14, 16, 17, 20, 21, 22, 23, 28, 29, 30 AM-4, 5, 6, 15, 25, 26, 27 AM-18 AM-1 (TYPICAL)

AREA RADIATION MONITOR CHANNEL WITHOUT AUX UNIT SENSOR &

CONVERTER RE

  • I LOCAL
  • TABLE 2 5

TABLE 2 RANGE SENSOR &

CONVERTER

.01-100 RE-3, 7, 8, MR/HR 9, 10, 13, 19, 24 INDICATOR &

TRIP UNIT RA-3, 7, 8, 9, 10, 13, 19, 24 6

TABLE POWER SUPPLY ES-53A ES-53B ES-53C (TYPICAL)

AREA RADIATION MONITOR CHANNEL WITH AUX UNIT PMIS TABLE 4 PMIS TABLE 4 SENSOR &

CONVERTER CONTROL POWER FROM LOCAL 120VAC DISTRIBUTION PANEL I

I I

AUDIO ALARM AM-* I LOCAL RE

  • I LOCAL
  • TABLE 1 I

I I

t AUXILIARY UNIT RM

  • I LOCAL
  • TABLE 1
  • TABLE 1 I

I MULTI-CHANNEL POWER SUPPLY FOR AREA RADIATION MONITORS


~-----r-------------------------7 I

I I

I 8

3 TABLE 4 CHANNELS PMIS SENSOR &

POWERED INPUT POINT CONVERTER 1-10 N091 RE-1 N092 RE-2 11-20 N093 RE-3 21-30 N094 RE-4 N095 RE-5 N096 RE-6 N097 RE-7 N098 RE-8 N099 RE-9 N100 RE-10 N101 RE-11 N102 RE-12 N103 RE-13 TABLE N104 RE-14 N105 RE-15 N106 RE-16 N107 RE-17 N108 RE-18 N109 RE-19 N110 RE-20 N111 RE-21 N112 RE-22 N113 RE-23 N114 RE-24 N115 RE-25 N116 RE-26 TYP (40B) 9-2

  • TABLE 3 ES-* I CR t

t

__._*--~'---

OPTICAL ISOLATOR I0-40A CR TYP (40B)

CONTAINMENT RADIATION RECORDER (MULTIPOIND 9-2 RR-40 CR 9-2 (TYPICAL)

AREA RADIATION MONITOR WITHOUT RECORDER, WITH OR WITHOUT AI.ARM RW (WITHOUT ALARM)

SENSOR CONVERTER RE-45A LOCAL RADIATION MONITOR RM-45A LOCAL (WITH ALARM)

SENSOR CONVERTER RE-458 LOCAL RADIATION MONITOR RM-458 LOCAL 2

18-53 A,B,C 9-11

  • TABLE 2 RA-"'

INDICATOR TRIP UNIT I

CR RA-*

INDICATOR TRIP UNIT I

CR I

I I

9-11

  • TABLE1 I

I I

9-11

  • --L __ L __________________________ J I

I I

I I

I

~--r-----------------------------~

I L---------7 r----------J I

I t

t AREA RADIATION RECORDER (MULTIPOIND RR-55 I

CR POWER FROM

/

120VAC INSTRUMENT BUS 9-2 DOWNSCALE TRI PS


7 I

r-------~----*---~-------~--------~-------~-------7 I

I I

I 9-~R ADMINISTRATION HIGH RADIATION HIGH RADIATION ALARM I

9-~R CONTROL ROOM HIGH RADIATION RA-458 I LOCAL I

9-~

REFUELING FLOOR AREA HIGH RADIATION RADWASTE BUILDING AREA HIGH RADIATION (TYPICAL)

PORTABLE AREA RADIATION MONITOR MPF RADIATION DETECTOR RE-60 TYP 61 62 LOCAL RADIATION MONITOR RM-60 LOCAL TYP 61 62 TIP ROOM HIGH RADIATION REACTOR BUILDING HIGH RADIATION (TYPICAL)

AREA RADIATION MONITOR ARW RADIATION ELEMENT RE-*

LOCAL

  • TABLE 6 RADIATION MONITOR RA-*

LOCAL

  • TABLE 6 TURBINE BUILDING HIGH RADIATION 9-k!;;R AREA MONITORS DOWNSCALE RANGE 1-104 N117 RE-27 N118 RE-28 N119 RE-29 N120 RE-30 TABLE 5 PMIS RADIATION INPUT POINT MONITOR N063 N064 DETECTOR RE-31, 32, 33, 34, 35 RM-40A RM-408 TABLE 6 AUXILIARY UNIT RM-AU31, 32, 33, 34, 35 RADIATION MONITOR RA-31, 32, 33, 34, 35 AUXILIARY

-PWR IN FOR PREVIOUS REVISIONS, SEE SUPERSEDED CARDS.

UNIT (LPAR 1)

REVISIONS BY N.P.P.D.

RM-*

CR NO.

REVISIONS DFT CKD APP DATE

  • TABLE 6 DRUM HANDLING N01 REV & REDRAWN PER APA DCN C93-1813 DR JAC WCF 10-26-93 CONTROL ROOM N02 CED 6014761 (DCN 05-1374)

DLR JDN KZ 2-1-11 3

4 5

6

~

8 3

9 10

-53A POWER

~CHANNEL SUPPLY 1

2 3

4 NUMBER 5 I 6

7 8

9 10

-538 POWER 11 12 13 14 SUPPLY 15116 17 18 19 20

-53C POWER 21 22 23 24 SUPPLY 25 126 27 28 29 30 INDICATION Ile TRIP UNITS FOR EACH CHANNEL WILL BE ARRANGED PER CHART ABOVE 1 1 SIGNIFICANT NUMBER GROUP 1

2 3

4 5

COOPER NUCLEAR STATION FUNCTIONAL CONTROL DIAGRAM 12 llQIES;

1.

SENSOR & CONVERTER TO BE MOUNTED AT 7 FT ELEVATION FROM FLOOR. AUXILIARY UNIT TO BE MOUNTED AT 5 FT ELEVATION FROM FLOOR.

2.

FOR SENSOR & CONVERTER LOCATIONS REFER TO INSTRUMENT DATA SHEETS.

3.

FOR LOCATION AND IDENTIFICATION OF INSTRUMENTS SEE INSTRUMENT DATA SHEET LISTED IN MPL FOR EACH INSTRUMENT.

4. ALL COMPONENT NUMBERS PREFIXED BY 18 EXCEPT WHERE OTHERWISE SHOWN.

REFERENCE DOCUMENTS

1.

791 E268 AREA RADIATION MONITORING ELE.

2.

791 E267 PROCESS RADIATION MON SYS.

3.

CNS-EE-78 MPF LLRW PLAN AND DETAILS.

INFORMATION ONLY 452005509 DRAWN I DATE DR 10-11-93 GENERAL 6

I DATE CHECKED JAC 10-29-93 ELECTRIC I

DATE APPROVED WCF 10-29-93

~

Ii:

FILMED REVISION AREA RADIATION MONITORING SYSTEM 921D796 SH 1 N02 ~

9 10 1 1 12 A

B C

D E

F G

H r---

CX) 0 J

~

~

0 0 u