1 A
I -
I 0::
I
~
I 0
(L N
B C
D I
I -
~
0::
I I
I I
0 LL
~ it it '
LL 0
(L N
N E
F G
H 2"FDR-1 j
1 2
I it
' N
~~~
I I
I 2
~
~
I I
I I
-I LL
-I
~
-;le
[L
-I p:
3 B~~ ------<;)
(RW-V-1206)
LEVEL 4 FILTER LEVEL 3 FILTER LEVEL 2 FILTER LEVEL 1 FILTER POWDERED RESIN TYPE 3
CONTAINER
-I it
' N
-I
~
4 1Yi' 4
5 6
'----'------7-------'-----s---------'------g-----'-----1-o ____
..J..._ ____
1 _1 ___
___Jc.__ ____
1_2 ___ ---,7
-I 0:: e 3/4"DEMIN FLUSH WATER MATCH LINE SEE 2032 SH 3 N
I
-I 0:: e
~
+.-:::AO:::t-_.,,,__[,'tlf--------'3-'---/-=-8'_' --"S'--'-A-_1'----------? ~~G 3 2010 1020 RW-SOV-SPV10 ZONE B-12 N
I
,u -
DWG 2032 SH 4 ZONE A-6&7 N
I N
I DWG. 2032 SH. 3 ZONE A-10 (RW-V-1208) 1Yi' RW-TVM-DSF 1"
11/2" 1 "CU-2 1----ie1--1H-::i---------------------'----"------=--------------.---'-----,
(RW-V-1223)
---,' TO LINER TV MONITOR 11/2" COALESCING FILTER SA-F-FCC 1" RESIN SAMPLE POINT (RW-V-1218) 11/2" (RW-V-1219) 11/2" (RW-V-1220) 11/2" (RW-V-1221)
(RW-V-1216)
.v4" DEM IN.
,-* +----'---;~-7c::....'-- FLUSH WATER
,--@---7 I
I 1
1 THERMAL
,--------------_J
- ENCLOSURE N -I > I
~ -
N -I > I 1/4" MESH
~,----'-,,--------,
4" 2*
(RW-V-1217)
Yi' (RW-V-1222)
ENTRAINMENT SEPARATOR I
17E-
~[::7 L~ :~
1/4" PORT FOR USE 4*
W/ BEAD TYPE 11---'------itlf-"'---_J RESIN CONTAINER FREON 1/2"SA-1 3/4"SA-1 DWG 2010 c_~-='----'----cJ------,,-"'---="'-----'-----? SH 3 ZONE B-11 CHILLER RW-CH-DS 1/2" RW-SOV-SPV610 XJ--------'-----'
SA-607
_J QUICK 3/4" CO U PU NG 1-*1--CJ---.(--txl-----'~)-'-------CJ-t-t~--~
(RW-V-1307)
RW-V-1224 3"
2" 5
FILL STATION t---,
SUMP PIT 4" FDR DWG. 2017 ZONE E-4 4"
DEWATERING PUMP RW-P-DSDP (RW-V-1211) 2" (RW-V-1213) 2" (RW-V-1212)
RW-F-BDCB
~
()
0 CD I
LL I
~
0:: -
~~
HEPA COALESCING FILTER FILTER RW-F-DSHF TO ARW BUILDING ATM.
-I 0:: e
~
i';:
[L 0
CD I
LL I
~
0:: -
3*
RW-F-BDPFB CL.LA PRE FILTER
~
~
N N
N N
-I -I Pl 820 I
I Pl
~
~
819 0::
0::
DEWATERING SYS.
BLOWER RW-BLWR-DSB N
I
})
I
- ~
-~
614 614 3"
MATCH LINE SEE 2032 SH 4 6
7 REVISIONS TO THIS DRAWING REQUIRES A REVISION TO THE CORRESPONDING ISOKEY.
8 4"
-I 0::
0
,LL FOR PREVIOUS REVISIONS SEE SUPERSEDED CARDS.
VERSIONS/REVISIONS BY N.P.P.D.
NO.
DESCRIPTION DFT DATE ENG AB 09 DR-2013-0599 DCN 13-2061 DJB B 04 1 GEHORN 9
RW-P-DSSP SIGNIFICANT NUIIIBER GROUP 3"PW-1 DWG. 2032 SH. 3 ZONE A-10 NOTE 10 rr---- 7 AO I 1013 I
l_L! ____ _J AO 1012
-I 0::
0
,LL -
DWG. 2032 SH. 3 ZONE A-10 NOTE 10 rr---- 7 I
AO I
I 1019 I
L_L, ____ _J AO 1018 N
I 0 ' -
AO 1014 CU_;2)P~-1
-I
~
[L
-I -I 0::
0
~
[L
- 1.
WHERE LINES ARE INTERCONNECTED AND CONTINUED ON OTHER DRAWINGS, ZONE NUMBERS ARE APPROXIMATE ONLY.
4 FLOW DIAGRAM AS DRAWN DATE HFY 10/1/01 CHEa<ED DATE 454223017 STATUS: Release STATUS DATE: 08/04/2015 DS APPROVED: GEHORN VER: AB REV: 09 SIZE: F BURNS & ROE a,
HIGH CONDUCTIVITY (FLOOR DRAINS, CHEMICAL & LAUNDRY WASTE) PROCESS COOPER NUCLEAR STATION R -
0 APPROVED DATE 0
~o t----,--~---------;
C FILMED SEE ~~EDED 2032 SH 5
~
10 1 1 12 A
B C
D E
F G
H j