UFSAR Revision 30.0 l

2

+

3 4

5 6

7 8

9

+

IGS069.,

A e

I I

C LETDOWN LINE FROM I

LOOP 4 SEE FIG.4.2-ll

............ 0.9~-~9~-----...

"'-0 1111---

,,..._,'-,/

NORMAL CHA~GING LINE TO LOOP 4 COLD LEG.

F,C. F C.

D LETDOWN ORIFICES 'r._

iClQ '

F.C.

,T>1 A,

F.C.

F.C.

E INSIDE,.,EAC:TOli!

CO~TAI\\.J M!.t..lT

.' 7 I

I F

G TO AND FROM COMPONE~

COOLING SYSTEM. SEE

..__I FIG.9. 5-1 OUTS I OE ~EI\\CTOJ.'

CON TA.I t-1 MEt.1 T I

~

LET DOWN FROM RES~DUAL HEAT REMOVAL SYSTEf1.

SEE FJG. 5.3-1

\\E.._T EXCHANGE!?

---~

H

.J

,I t

{OF!

TO DRAIN HEADER FROM SAMPLING SYSTEM K

L

.... 1 "!2P1'1 1

M

(

TO DEMINERALIZERS SEE FIG. 9. 2-2

\\_ FROM DE~INERALIZERS S!::E FIG, 9. 2-2 TO HOLD-UP TANKS SEE FIG.9.Z-4 N

0 SEE FIG. 4. 2-. ------.\\

ro e,,;;;;;,rn R ELIEf TANK I I_/'...

.*"'-SEEFIG. 4 *.*

2.-lAlllllllll'11C:&J-~'K-)--------..

r ~,.

s_E_E~FIG.11,1-1 ~

SEE FIG.9.5-l

\\_

~

I "'

REACTOR.

l

  • l I r6PC\\

\\.__)

~ J F. C.

_I..

TO VENT HEADER

. _SEE FIG. l?

ALT. CHARGING LINE TO LOOP 1 COLD LEG.

SEE FIG.4.2-1---~

F. 0, TO AND FROM COMPONENT COOLING SYSTEM. SEE REGENERATIVE 1 1 HEAT EXCHANGER TO REACTOR COOLANT DRAIN TANK SEE FIG.11.1-1 FIG, 9-5-1 -- ------"-

FAIL TO RCDT

~ ~'

\\fl l/1 -2 llJ 0

,n z -

EXCESS LETDOWN FROM LOOP 4 SEE FIG.4.2-l F.C.

FC.

I Q

\\.._,,/,

~

_ 1-1** l*-~~- A~i----.

r

~

FC 'il

-.,~

.;r EXCE.S~ LET OOWN

/4Pl' HEAT El(CHA~GE~

\\.__,...


~

/

.--~---------/-,--

u.l 0 -

Ii>

t--

0 FROM REACTOR COOLANT PUMP SEAL WATER CIRCUIT ( 4 PUMPS)

SEE FIG. 4. 2-lfa.

TO REACTOR COOLANT DRAIN TANK SEE FIG. 11.1 - 1 V

I I

I I

'

  • t

[Q"TI

\\

  • I FC.

{QPi'\\

TD SUMP I

(QPI'

\\_,,,

/

TO ANO FROM COMPONENT COOLING SYSTEM. SEE FIG. 9, 5 (QPI'\\

\\_)

...J

~,

SEA.L WATER

'* FILTE.R

~

I

'"LI-SE1'L WATE~

HEAT EXCHANGER a.* I_.

~

FROM SAMPLING SY'.:> ~~-.[->I-'

TANK THRU DRAIN

/1..-,1~~-----------

HEADER SEE FIG. It. 1-1

,.. '.,irorn RtCIPROCATING PULSATION DAMPER,----+---.. \\J CHARGING PUM? _


~~-

~

'~

~-l-k'*:,.*---t---4!111111,-llf

.7 ~ "

~ *L,C.

QPI

!r

--',J

\\

.h

',,___,.J TO PRESSURIZ::R REL:EF TANK SEE FIG.

4. 2-1;7

"-.,__C_~OL~NT I

I~

J

, L ~LTE lot J *.'ODA,

,r

. ----*--11*.

{QPt\\ - "

-~- ~

\\._,J I

II.

\\'---'l

,,- TD AUTOMATIC GAS

-4:*~*..:-t ~.~,__;J,4~--*'

ANALYZER SEE FIG. 11. 1-4 I

.1os1\\

\\

1 L rm ~,;;_/**,..* p-----!1-~-::_f

____ PI:*

TO HOLD-U~ TANKS SEE FIG.9.2-~

NOTE:

SYSTEM LINEUP SHOWN FOR NORMAL OPERATION. BORIC ACID MAKE-UP SYSTEM IN STANDBY ALIGNMENT.

VALVE POSITIONS ARE NOT GOVERNED BY THE UFSAR FIGURES BUT RATHER BY STATION PROCEDURES (EXCEPT VALVES WITH LOCKED OR SEALED, AND FAILURE POSITIONS AS INDICATED),

.I VOLUME CONTROL TANI<

~ ~

6fh TO WASTE

~

HOL)-UP

'-.__./

TANK THRU

[V ORA.IN HEADER '... ~

F.C, SEE FIG,11.l-1 FROM BORIC ACID BLENDER SEE FIG. 9,2 - 3 t:

1

.. 1 r...

I c r

' ii.

, c___.- MAKE-UP TO REFUELING WATER STORAGE TANK SEE FIG. 6. 3-1 FROM BORIC ACID BATCHING TANK SEE FIG_ 9.2 - 3 TO HOLD-UP &

BART TANKS SEE FIG. 9.2-4 FROM CONCENTRATES HOLDING TANK TRANSFER PUMPS SEE FIG. 9.2 - 3

REFERENCES:

llf'-1 (2)-5129 P-1 12>*5129A 1

2 3

4 5

6 INSIDE RE,4,CTO~

CONTAINMENT (QPI,

\\_.,, J

~

FROM REFUELING WATER STORAGE TANK,

... -+-t--------t--17 A

TO REACTOR COOLANT PUMP SEAL WATER CIRCUIT (4 PUMPS)

SEE FIG.4.2-lA

__J B

- -OUTSIDE REACTOR CONTAINMENT 5f.lAREO Dt'IICE ~

ro_i::1, Ci-!AP.6,N(~ PUMP C'R0'::>5*TIE TO/t=?sOM OTl-!EI".. UN\\T TO BORON INJECTION TANK SEE FIG.6.2/

F.O.

f----tl

',t-

--..... -..... _--11*1- L DRAIN TO SUMP TANK THRU DRAIN HEADER SEE FIG.11.1-1 ~

QDA I

I I

I

.... ~~._ _

I I

SEAL WA.T._R INJECTION l'ILTER~

C D

E TO BORON INJECTION TANK SEE FIG. 6. zy

( ONE FILTER NORMALLY IN SERVICE. I CM l 3

4 5

6 7

  • *"R" COMPONENT COOLING WATER SEc FIG.9.5-1---'

/oPI\\

\\,_)

t"'.'

,.,C!:Nl"RIFUGAL

<X j ~ CHARGING 1 '

PUMP COMPONENT COOLING WATER TO ~ FROM BEARING AND GEAR OIL COOLERS

\\

R :- r-SEE FIG.9.5-1 --

j j

I CE l<ITR I ~UGA. \\.

C\\-11>..RGING PUMP COMPONENT COOLING WATER JO ~ FROM BEARING AND GEAR OIL COOLERS SEE FIG.9.5-1 G

' \\

H y

LO 12 16 J

FROM BORIC ACID SYSTEM SEE FIG. 9. 2-3_.7

... 1 t..

/

FROM PR:MARY ~ATER

& BORIC ACID TANKS SEE FIG.9.2-3

,~

,,,--- FROM CHEMICAL

, -/

MIXING TANK I

,,,--- FROM RESIDUAL

/

HEAT EXCHANGER

._~----------

SEE FIG. 6.2-1A 1-BACK UP CROSS-TIE t

TO & FROM SAFE[Y

.__ __..,. :NJECTION PUMPS SUCTION HEADER SEE FIG. 6. 2-1 TENTHS 10 I(

20 30 L

SEE FIG. 6. 3-1 INCHES I

M 2

3 N

4.

REVISED: PER UCR-1989 D.IITE NO.

DESCRIPTION REVISIONS FILENAME: fsor-fig-9.2-l 24,dgn (roster file): fsor-fig-9.2-l 24.til APPD.

"THIS OR/I.VINO IS Tl£ PROPERTY OF THE AMERICAN ELECTRIC POWER SERVICE CORP. AIC> IS LrlANED l$IOtrl CONDITJON THAT IT IS NOT Tl'I BE REPROOUCED OR COPIED. JN 1/tQ.E OR IN PART, OR USED FOR F~-

8 NISHINO Ul"<AtllTIDN TO ANY P1:RSON VITHOOT THE WRITTEN CONSENT OF THE AEP SERVICE CORP.,OR FOR ANY PUU'OSE DETRIHENT AL TO TH!IA INT!;:AEST, At<<> IS TD BE RETLIU£D UPON R£0l.EST" INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT BRIDGMAN MICHIGAN eves - REACTOR LETDOWN g, CHARGING UNITS NO. I OR 2 DWG. NO. fSAR FIG. 9.2-1 MICH ELEC DESICIIII DIGDEEAINU DlmllONI MECM STR AEP SERVICE CORP.

1 RNERS/DE PLAZA COLUMBUS, OH 43215 0

9 fsar-fig-9.2*1_24 dgn 02123/2012 1 :33:18 PM Check Print. S469537

FSAR FIG. 9.2 - 2 CVCS REACTOR COOLANT DEMINERALIZATION UNITS NO. 1 OR 2 VALVE POSITIONS ARE NOT GOVERNED BY THE UFSAR FIGURES BUT RATHER BY STATION PROCEDURES (EXCEPT VALVES WITH LOCKED OR SEALED, AND FAILURE POSITIONS AS INDICATED).

UFSAR Revision 30.0 2

3 5

6 8

9 A

FROM C LETDOW SEE Fl VCS N LINE G. 9. 2-1 TO eves REACTOR COOLANT SEE FIG.

FILTER

9. 2-1

~ -

\\RIMARY WATER A

DEMINERALI WAT£ "'

ZEO

' ~

a B

l B

C D

E F

~

FAIL TO ~OLU ME CONTROL TANK

-' ~

TELLTALE~

J l

{.'11:LLTl>.LE l

,~

, \\

J ),

1'1;G.ENE"ANT CH~MICALS

~,.

I -

I -*.. --

LRESIN FILL rfiRESIN FILL l

,l=-*

(Z) DEBORATING

.!I DEMINERALIZERS 1 I

1

.!II 1 ~

(QFI\\~

-\\___) - -

J ),

~..

I -

t r *1.....

...i.

J )

[TELL TALE

.I

{TELLTALE

  • ~

'~

J )

l 1

~

I..

TO DRAIN HEADER SEE FIG.11. 1-1 C

D E

CM l 4

5 G

H

-* u --

QFI

~

,I, RE';IN RESIN Fill\\:,

FIL~

~.

u*

t CATION BED OEMINEll.l\\lll.ER l

'1

-* ~

J r

~

~

)

'I, t

~...

~

G H

12 16

.J K

L R!:SIN Fill, r:,

.~

l I l 1

J

,..µ.." *-*

(2) MIXED BED DEMINERALIZ.ERS

~

J

-l),

J J

'l

'. L TO SPENT RESIN STORAGE TANK SEE FIG.11.1-2 J

TENTHS 10 K

20 30 L

M

\\_ TO DRAIN HEATER SEE FIG, 11. 1-1 INCHES M

N N

0 NOTE:

LINEUP SHOWN HAS ONE MIXED BED DEMINERALIZER IN SERVICE, OTHERS IN STANDBY. OTHER LINEUPS ARE ALLOWED IN ORDER TO CHANGE, SWITCH, FILL OR DRAIN DEMINERALIZERS.

REFERENCES:

0P-1 £2)-5130 2

5 6

0---+-1---------+---II 7 REVISED PER UCR 9~-UFSAR--0589, 99-UFSAR-ll52,99-UFSAR-nas 1:EVISIONS FILENAME:

fsar-fig-9-2-2.163 (rasterfile):fsar-fig-9-2-2163.cit "THIS DR.t.llHJG IS THE PROPERTY OF THE AMERICAN ELECTRIC POWEil SERVICE COl:P *.t.f.10 IS lO.t.NEO UPON <;ONOHION THAT IT I$ NOJ TO 5E REPRODUCED

~~Si~:~E~~Fi:M:~~ :; :zyp;;;;O~\\~;:iu;o;H;UR-6 IIRITTEN CONSENT OF TI-£ AEP SERVICE COl:P.

  • DR FOR ANYPIJRPOSEOETRIMENTALTO THEIR INTE:REST, ANOISTOBE:RE:TURNE:OUPONREQIJE:ST' INDIANA MICHIGAN POWER COMPANY DONALD C. COOK DWG. ND
  • ARCH NUCLEAR PLANT STR AEP SERVICE CORP.

1 RIVERSIDE PLAZA COWMBUS, OH 43215 0

9

fsar-fig-9.2-3_21-2.dgn 3/7/2008 10:30:02 AM UFSAR Revision 30.0

+

5 6

7 8

9

+

A TO VOLUME CONTROL TANK OR CHARGING PUMPS SEE FIG.9.2-1, IGS069' A

TO MISC. DRAIN TANK SEE FIG.

10. 5-SA B

TO CHARGING PUMPS UNIT NO. I SEE FIG. ~- H r

4ai:-LOO~

l)li'AIN B

C C

D TO~ LOOI.! Dli!'l'IN f!IO'CIC ACID FIi.TU, UNIT NII E

!="ROM PAIMA.RY WA.TES<

MAKE-*UP PUMPS F

T.C.

t-"lt!ll"".. TOFLOOR DRAIN FROtll PRlM.-_RY W"-TER MAKUP PUMP$---~

G H

HR" F.C.

J FROM CONCENTRATES HOLDING

-ANK TRANSFER PUMPS SEE FIG.9.2-5 LTo i=LooR Dli.'A1 N (3J BORIC. ACIC TANKS I(

L F.C.

DEMlMF.-RA.L I Z~D WA1£R

_,_......... ______..,.~_1131 ___

TO CHARGING PUMPS UNIT NO. 2 SEE FIG. 9. 2-1 D

STEAM SUPPLY FROM AUIC. STEAM

~YS"l'EM.

E CM I 3

4 S

6 7

G TO BORIC ACID

._+-C:&:1-+-,._ BLENDER OUTLET SEE FIG. 9 2-1 3i&INCH 4 H

12 16 J

TO VOLUME CONTROL TANK OR CHARGING PUMPS SEE FIG.9.1-1 l BOR.IC,\\CID BLENOE.R.

UNIT Mli-'2.

  • ----r 30 L

INCHES M

TO BORIC ACID BLENDER OUTLET SEE FIG. 9.2-1 N

D

-._TO ~LOOR DRAIN NOTE.

1. LINEUP SHOWN HAS ONE BAST ALIGNED TO EACH UNIT, ONE BAST ON RECIRCULATION AND THE BATCH TANK ISOLATED OTHER LINEUPS ARE ALLOWED IN ORDER TO RECIRCULATE, TRANSFER, DRAIN AND FILL BASTS AND THE BATCH TANK.

VALVE POSITIONS ARE NOT GOVERNED BY THE UFSAR FIGURES BUT RATHER BY STATION PROCEDURES (EXCEPT VALVES WITH LOCKED OR SEALED, AND FAILURE POSITIONS AS INDICATED).

2, VALVE INTERNALS REMOVED PER 12-LOCP-889.

REFERENCES:

OP-11*5131 5

6


7 21.2 REVISED PER UCR-1887, REV. 0.

DATE ND.

DESCRIPTION APPD REVISIONS

-THIS DltAIIINO 11 THI! ~ltTY 01' THI! AMERICAN ELECTRIC POWER SERVICE CORP. AND 11 LCIAIED uPOII CONDITION THAT II IS NOT TO BE AEPRCIDUCED OR COPIED. IN WHDLE OR IN PART, QR USED Fmt Fl.R-NIIHINO IWCIRMATION TO ANY PERSON IIITH0UT,...

WRITTEN COldEIIT OF' THIE AEP SERVICE CORP.

  • DR FDR ANY PI.RPOSE DETRIMENIAL TO IHEIR INIERl:ST, AMJ IS TO BE AETUUED I.PON REIIUEST" INDIANA MICHIGAN POWER COMPANY DONALD C. COOK BRIDGMAN NUCLEAR PLANT eves - BORON MAKE-UP UNITS NO. 1 fir 2 MICHIGAN DWG. NO. fSAR FIG. 9.2-3 NECH SIR CHI*

AEP SERVICE CORP.

1 RIVERSIDE PlAZA COLUMBUS, OH 43215 0

8 9

UFSAR Revision 30.0 1

2

+

3 4

5 6

7 8

9

+

A B

C D

E F

G v-Z'6'91:I 1:1\\1S:I 'ON '!>Ma FROM NITROGEN SUPPLY MANIFOLD. SEE FIG. 11.1-4

~

TO VENT HEADER FOR CONT. SEE FIG.11.1-1 FROM UNIT N0.1 REACTOR COOLANT DRAIN PUMP SEE FIG. 11.1-1 FROM UNIT N0.1 REACTOR COOLANT LETDOWN. SEE FIG.9.2-1 FROM VOLUME CONTROL TANK RELIEF VALVE (UNIT NO. ll SEE FIG.9.2-1 FROM UNIT N0.1 BORIC ACID BLENDER SEE FIG.9.2-1 _ __J FROM CONCENTRATES HOLDING TANK TRANSFER PUMPS FROM UNIT N0.1 BORON INJECTION TANK SEE FIG.6.2-1...__

ACCUMULATOR TEST LINE SEE FIG.9.3-1 SEE FIG. 9. 2-5----+----l'--.....,4..J FROM MONITOR TANKS PUMPS SEE FIG.9.2-6 __,r L FROM SPENT FUEL PIT PUMP SEE FIG.9.4-1 HOLD-UP TANK A.REA~

SUMP PUMP ALT DI SCH.

FROM UNIT N0.2 REACTOR COOLANT DRAIN PUMP SEE FIG.11.1-1 ~

FROM UNIT N0.2 BORIC ACID BLENDER SEE FIG.9.2-1~

FROM UNIT N0.2 REACTOR COOLANT LETDOWN SEE FIG.9.2-1

~

TO SPENT FUEL PIT TRANSFER CANAL SEE FIG.9.4-1 A

B C

FROM GAS DECAY TANK SEE FIG.11. 1-3 t_ TO AUX I L I AR 1 BUILDING SUMP (s) I-IOLO-UP TANKS kt,'

y_,_

QP!

(3) BORIC ACID}

EVAPORATOR FEED PUMPS TO AUX BLDG VENT SYSTEM see FIG 11. 1-3 FROM NITROGEN

~~-----~~--~ SUPPLY MANIFOLD see FIG.11. 1-4----t-----a.

FROM UNIT N0.2 BORON INJECTION TANK SEE FIG.6.2-1 ACCUMULATOR TEST LINE SEE FIG. 6. 2-1A FROM VOLUME CONTROL TANK RELIEF VALVE (UNIT NO. 2)

-l..<JIIIF""""--*-

0-SE_E_FI_G_. 9_. _z-_; ______ ~*-**

HOlD*U? TA.NI' RECIRCULATION PUMP D

E CM I 2

BORIC ACID RESERVE TANK

.. ':_j_ *-'

3 4

S 6

71 c97x I I

OLA FROM ION EXCHANGER FILTER UNITS N0.1 ~ 2 SEE FIG. 9. 2-5 G

QPA H

( )

.___J QPI QPI H

RE51N FILL CONNECTION

\\_TO ION EXCHANGER FILTER. SEE FIG.9.2-5 12 15 J

~ENTHS K

L (4)EVA?ORATOR i=EED lON E.)(C.1-lANGE:R S 10 K

20 TD WASTE HOLD-UP TANK THRU DRAIN HEADE~

SEE FIG.11.1-1 30 L

RE.5\\N FILL CONNECl'ION M

=NCHES 1

M N

TO WASTE HOLD-UP TANK THRU DRAIN HEADER. SEE FIG.11.1-1 ~

PRIMARY WATER FOR t'LUSHINGl I!

L TD ION EXCHANGE FILTER. SEE FIG. 9.2-5 TO SPENT RESIN STORAGE TANK SEE FIG.11.1-2 3

N 0

NOTE:

eves HOLDUP TANKS ARE SHOWN ISOLATED. OTHER LINEUPS ARE ALLOWED IN ORDER TO FILL, VENT, REeIRCULATE,RETRANSFER,DRAIN OR PROCESS A eves HOLDUP TANK.

VALVE POSITIONS ARE NOT GOVERNED BY THE UFSAR FIGURES BUT RATHER BY STATION PROCEDURES (EXCEPT VALVES WITH LOCKED OR SEALED AND FAIL URE POSITIONS AS INDICATED).

REFERENCES:

1 2

3 4

5 6


f----+-----

---+------117 18.0 REVISED PER UCR-1347.

or..TE t*o APPD

fsar-fig-9-2-4 _ 18--0.tif "n-ffS DRA..,.I~:6 IS THE FROP:CP.-:-Y OF THE AMER.[CAN ELECTRIC POWER SERVICE CORP. AND IS LO."-NED lJP(iN CONOr TIVN THAT l '"" i S ~1-:,1* l"() BE RE::,-,R:JIXJCC.Ll

-:-R COPIEO. IN,it--lOLE 0~ rn PART.

Oc< ~;s,:-n l"'GF<. _::uR-8

"'lSHINI:: l"'iFORMATIO'J - 8 ANY ::>CORSON \\i/ITHOUT Tl-iE

,-R1r;;
t,.1 c:O\\SErH CF 1w::

AEP SERVICE COR:P..,o~

1"0.11: AN':" l" :.1RF'OSE DETRHIF.NTAI. TO THEIR TNIFRFST,

.WD lS T-J :!E RET'.,HN;:;O UPON R;:;,;;:i:JEST'"

INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT BRIDGMAN MICHIGAN CVCS-BORON HOLD-

__....--.1 and BORIC CID ESERVE UNITS N0.1 and 2 DWG. NO. FSAR FIG. 9.2 - 4 ARCH ELEC Ml'CH STR

scu, CH:

f'fl'!f'f AMflHC:AN AEP SERVICE CORP.

j/,if l'lfC:fl'IIC:

1 RIVERSIDE PLAZA POWER COLIJMBUS, OH 43Z15 0

SYSTEM u.o.-i;: r,,rov-wo2 S"f"STEH TIM'c-l~ 00 9

VALVE POSITIONS ARE NOT GOVERNED BY THE UFSAR FIGURES BUT RATHER BY STATION PROCEDURES (EXCEPT VALVES WITH LOCKED OR SEALED, AND FAILURE POSITIONS AS INDICATED).

4.

FSAR FIG. 9.2 - 5 FLOW DIAGRAM CVCS-BORON RECOVERY UNITS NO. 1 & 2 Revised Per UCR 99-UFSAR-1343 16.6 16.6 UFSAR Revision 30.0 9

PRIMII.RY WATER FOR FLUSH\\ NG.

CONCENTRAT!:S

!-\\OLDING TANK i--

1 I

I I

I I

I ELECTRIC Hl:ATER.

ABSORPTION TOWER~

~E.E. THl5 DWG,L/7-----------

-t.... ~----------~---

ElECTRIC HEll.l'ER F.C,

'(

'LORAIN iO FLOOR STEAM SUPPLY------..

NITROGEN SUPPLY SEE FIG. 11.1-4~

r-*-- *-- --

TO VENT HEADER

_J SEE FIG. 11.1-1 EVAPORATO~

TO DRAIN HEADER SEE FIG. I L 1-1 E

STE AH CONDENSATE TO EVAP COIL ORA IN TANK SEE FIG, 10. 5-4A

('LJ S'ORI C ACID CONCENTRATE PUMPS CM I 2

3 4

5 G

G

\\ sJNCH 4 N

TO ~ FROM COMPONENT COOLING WATER SEE F!G,9.5-l i

~~

I

~-,}---,---~---'

LOCll.l~

F.O.

TO CONDENSA TE DEMINERALIZER SEE FIG. 9, 2. -6 L_ __ ----,

STEAM CONDENSATE DRAIN TO EVAP COIL DRAI N TANK SEE FIG. JO. 5-4A STRIPPING, COLUMN7 TO HOLD-UP TANKS

\\

SEE FIG. 9.2-4 FROM EVAPORATOR FEED ION EXCHANGERS SEE FIG.9. 2-4 i PRIMl'.R'f Wl'.TER FOR FLUSHING FlllSI-IIHC.

~~~ T~H~~A?. *---111"1f----t DWG.C/<o (21 D\\ST\\LL"-TE PUMPS TO DRAIN HEADER SEE FIG. II. 1-1 (2) ION EXCHAt-lGE FILTERS 12 J

TENTHS 10 K

20 L

I NCi-ES M

N 0

NOTES:

L NBAE LINEUP SHOWN FOR SHUTDOWN CONDITIONS. OTHER LINEUPS ARE ALLOWED, INCLUDING THOSE FOR PLACING INSERVICE FILLING, RECIRCULATING, BA DISCHARGE, DISTILLATE DISCHARGE, DRAINING, PRESSURIZING AND VENTING.

2, ONE NORMALLY INSERVICE.

3. INTERNALS REMOVED.

REFERENCES:

FROM WASTE EVAPORATOR FEED PUMPS SEE FIG. ll. l-2 5

6 t--+-+---------+--11 7 REVIStONS FILENAME:

fsar-fi11-9-2-5.163 (raster file): ha r-fig-9-2-5 163.cit

" THIS ORAW'INO I S THE PROl'ERTT CF" THE AMflJCAN ELECTltlC POWEi SEIMCE COIP. ~

IS LO.....,D IJl'ON CONOI H ON TIU,T JT [ S NOT TO 8E ~~UQ:;C

s~:~i.~~i:.:~: ::.P::~: w~::u:o;H
UR-B

>.;UTTEN 00-SEI-IT o-n-i.:

AEP SERVICE CORP'., OR FOil MN PURPOSE OEHHMlil'tT.._L 10 <HEI R UIT£RE:ST.

INDIANA MICHIGAN POWER COMPANY DONALD C. COOK BRIDGMAN DWG, NO.

NUCLEAR PlANT MtCtmlAN STR AEP SERVICE COM 1 RNERSIDE PLAZA COWMBUS, OH 43215 9

VALVE POSITIONS ARE NOT GOVERNED BY THE UFSAR FIGURES BUT RATHER BY STATION PROCEDURES (EXCEPT VALVES WITH LOCKED OR SEALED, AND FAILURE POSITIONS AS INDICATED).

17 Revised per UCR-1440 17 17 OP-12-5134 FROM OR TO MAIN CONDENSER DISCHARGE (VIA WASTE DISPOSAL SYSTEM)

SEE FIG. 11.1-2

REFERENCES:

17 FSAR FIG. 9.2-6 CVCS-MONITOR TANKS UNITS NO. 1 & 2 UFSAR Revision 30.0 2

3 4

5 6

7 8

9 A

9-Z6'!ll:I 11\\fS:I 'ON -~Ma RIC ACID FROM BO EV AP ORA NO. I, DIS COOLER SEE FIG TOR PACKAGE TILLATE OUTLE Tl

. 9. 2-5 '

ORTlMl<PIJIIPS FllOM MONIT StE B

C y

/2rn\\

,~

_J *

"l J -

,l ffl7 L

DI LUTE CAU5'T IC~

JC ACID/ RAMASTE, ATOR DISTILLATE FROM BOR

[ VAPOR COllER SEE Fl OUTLET G.9.1-5 SOLUTIOI.J "l

ll.T

/Qm TO DRAIN HEA~./

SEE FIG. 11.1-1.

A B

C

.J )

"l

.J D

E F

G H

u -

RE51N FILL CONNECTION f ~ (TYPICAL)

~

lt TO DRAIN HEADER

(

SEE FIG. 11. 1-1

)l (2.l EVAPORATOR

"-'~\\

CONDl:.NSA'TE CONDENSATE PEMINERAL.11.ERS FILTER

' r-(

.J L.

~

i

~

L.,.I

~

v J

1 TO SPENT RESIN STORAGE TA~

~

lWASTE DISPOSAL SYSTEM)

SEE FIG. JLI-1

.J,_

~

TO DRAIN HEADER SEE FJG. 11.1-l

.J L.

QFl

' ~

PRIMAR'( WATER

a.

)L T

"'"'"'\\

CONDENSATE FILTER

~

~

..J )

lt

..:l )

j

)

"'l

(

1

..:l)

TO DRAIN HEADER SEE FIG.11.H

~

D E

CH I 2

J 4

5

~

7 G

H 12 J

l J

C a )

  • 1J K

L M

N 0

r

.... ~

I

~

('2) eves MONITOR 1

'T~NK~

r J

3

~

1_

J ~

NOTE:

1 MONITOR TANKS ARE ISOLATED, OTHER LINEUPS ARE ALLOWED IN ORDER RECIRCULATE, TRANSFER, DRAIN TO FILL, 4

OR RELEASE A MONITOR TANK.

UNIT N°\\

-"TO PR1MAl2'< Wo\\'iE:R.

STOQAC,E TA~K.

-y UNl"T N*'2.

TO PRIMARY WATER

,I J,

5TORAGE TAN 1<.

~

~

t)~

I IXl V I

C N::

,I J,

~.

L--"""

~.

TO H0*0UP TANKS J\\ )

SEE FIG.9.H

~~~

.. ~

~

~,

)

(Z) MOMITOR

~

-TO EVAPORATOR CDNOE.NSATE TANK PUMPS 5

DEMINERALIZER', SEE THIS DWG, A/4

('

o-,..

.r

~

.,,_ l -

JL

---1--.117 DATE NO.

DESCIH F>TICJN J ~

REVISIONS (2) WASTE 'f'NDE~§ATE "TH IS ORAW!H(l I S Tf-1( PROPER TY Of ELECTRJC PO'W'B SHYICE CORP

  • t:::]Ql,IIIQ!!. Am:~

UPON CCl>C)!T ION l >tAT l T Ill NOT Hl TH: AMERICAN llE ll:EPROOUCiO r

-h-.

..r LA

~ I -

JL -

., 5 1

TENTHS 10 K

20 L

INCHES M

N OR COPIED, IN WlfOI.E GRlt-/ PART, Ollw~S:u: o~

tJR-8 ICE CORP.,OR NISHINO IHFORMATI ON TO Ntl' PERSON WRITTEN CON.sENT OF TIE A.EP SEIV

~ DR ANYP\\J~

SE DE:111:IIEHTALTO tlED INTEREST, A~

I S TO eEfiEfUR~Ul'ONREllU: S T" INDIANA MICHtGAN PO WER COW ANY DONALD C. COOK NUa.EAR Pl.A. NT 9

DWG. NO.

'"" I I ELEC I I MECH STR OAT[I

,~.

DR!fM~IC DI¥1UIJoll m fllc'lfc*

~~~~ffl ~-

POWIII COJ1JMBUS. OH 43216 0

...\\fsar-fig-6.2-1A&9.3-1_27.dgn 6/1/2016 7:29:24 AM 1

2

+

3 5

6 7

8 9

+

A B

C D

E 1 *

\\_TO O'TJ-16.-,

AtcUMULATOR~

... ccUMUL... TOR T,t\\Nk F

0

~

I

~.

F,C.,

~

H J

rim FROM NITROGEN

'-.,,,I SUPPLY MilNlFOlD SEE FIG. Ll, 1-4

.. A TO AND FROM COM~ONENT I(

L t 2 > RE':IIDUAL HEi\\,T E>CCMANC..ER.~

TO AND FROM COMPONENT M

'+----1 I-COOLING SYSTEM _____ _,.

SEE FIG.'3,5-1 E

COOUNl.l S't'SfEM SEE FI0,9.5-1 w

I-z z

w lJJ

==

~ z 2

~

~ z z

0 0

u

(.)

c::

c::

0

§ I-u

~

i'.fi rr::

UJ lJJ Cl

~

fO PRESSURIZER F.tF~"\\.

RELIEF TANK SEE F IO. 4. 2-1

~

Cl ci5

-TO REACTOR COOLANT S1STEM COLD LEGS SEE F1G.4, 2-L LOOP NII ti) 2 I

ro REACTOR COOLANT GD III 0R.\\IN TANI< SEE

~ ~ FIG,11, 1-I To ACCUMULATOR

, ~

TANKS F:C

~---

I A

I LISX~*

1lo.2 No,-_3-No"""'

..?-

I

.\\

f

....~ '"'

I ACCUMULATOR FILL

~

~ *

  • I I-5 TO UPPER CONTAIN-MENT SPRAY HEADE~

,~'Ft.:

I..

~

~

~

..L

\\.

J -

i. TNE SEE FIG. 6. 2-! ::;;;;~j~_l~~--.J~* F:;:.c:._J...,...JLJ' ~-

1


i.iii-----t<

.~.t I SEE FIG, 6, 3-l--._._

~

.i-. --*: -----~-..

~

~,..-

LOOP N'I I

I I

I I I

I I

I * /Ii

~1-f<')III" _______.... F re 11or LEGS (Res, LOOP Hi ?a I

SEE FIG.4.2-1

~ *

1

~*\\

' ~'"'}j

~

TO FIRESSUUZER

~

REltEF TANK SEE FIG, ~, 2-LA FROM SArETV INJECTION PUMP IN) DISCF.IARGE L~~ H~ I I t ~, ___________ _

SEE FlG,6,2-1 ~-

~.

FROM LOOP NO. 2 TANltS, SEE FI~. It, 2-l~ -

I Lim

.1 '

......$ROH'SAFETY INJ~CTl0N

__,.-, ~

PUMP (S) DISCHARGE

~*.....--~

SEE FI0,6.2-1 I I

  • I

' ~

TO CHARGING PUMP SUCTION HEADER _J SEE FIG. '3, 2-1 I

(

I r FliOH Ri;J1JE~ING WATER STORAGt TANI<,

SEE F[G, 6. 3-1 REFUELING llA TER RETURN SEE FIG,

s. 3*1 la(:;::.:~-----

j TO PRESSURIZER RELIEF HOT LEG SEE

~

F!G., 2-l ----..tllllj:~

.... -~... --------.. =--------M~-~--*-~-----------------..

TO Ofl.lfll 1/,td.,VI

_J I

ENCI..O!)IJ~I."'\\ ----**

MQ'TCll lOCil.TEC 1**-**-**----**-**-

~NS\\D'i ~-~~~!_7_...., l!:r

- \\_

G~--

l'Il.,ti' C

~l:~T REMOTE POCKET STRAINER POCK ET

-:111 STRA INER,

~...... J

--~.....

~

\\.

.J r

!'~OM. OT~l."-

V.DI\\. \\I I. 'iii NC.\\..O 111,.UI I.

F I

L.C

  • r 1 I

.- 'JO PRESSURIZER RELIEF rANI<.

SEE FIG. 4. 2-L

-""' 1, I ~

-i1,

.I:

---el-!"l-4..... --*-o~-tMt-KJ'l4~--I I I

~

I I...o.

  • \\......I'

-"' "\\..

__ / _________ -..... _":'~L.~

V ' -'i>> _

-TO SAFETY ~NJECTION, TO lPPER CONT.l.IN-

~

PUH? SUCTIOM, MENT SPRAY HEA_D_ER_/

n.t, L SEE FIG, 6,,-1 SEE F'IG. 6, 3-1 F. D,

~

\\

/

TO CHEM.

~ VOLUME CONTROL SYSTEM F'OR PURIFlCATION

.SEE F.lG, 9, 2-:-l.

' I

\\.

7

~--11-----------t,1:_*_L_.0_._-I.--"'~ ~ JL,C

~

I T

i ~-' '*

~

, VIJ..\\/oe.

27. 0

~

! i:NCt.OSUft -

I L-*-**-**-**-**-**-**-**-**-**-* -**-**-**-**-** **-**-:,

tQ M!Slt>UH. 1-il!AT Rl!MOV-'\\.: -

~ -

,,)

P.UW! R00M SUMR 01'1-1111 V._l..'VI.

'TO COlf?'AINMENT SPRAY EMC\\.D!.urt! ~IN TO O"TM a11 SYSTEM SEE FJG, 6. J-1 ReSl0UA.\\ HEAl PUMP ROOM SUMA __,

RECIRCULATION SUMP IGS069.4 A

B C

D E

CH I 3

4 5

6 7

0 316 INCH 4 H

12 I L.0.

16

/

)E

.I J

TENTHS 10 I(

20 Le t:!.' P.ESICUAI.. HEAT P.!ti10VAl. PIJMP~

30 L

INCHES M

2 I

w J

L.0, N

0 NOTES:

1, VA""LVE JEST LINES NOT SHOlrN.

2, SYSTE~ IN STANDBY READINESS titv~C~~s?ti~RJJ~w~ NOT GOVERNEO BY THE UFSAR FIGURES BUT RATHER EIY Sl"A.TION PROCEDURES (EXCEPT VALVES WITH LOCKED OR SEALED, AND FAILURE POSITIONS AS INOICATEC).

REFERENCES:

OP-I 121 -5143

\\

1 2

3 5

6


+--7 1

REVISED PER UCR-2096, REY. 0 AND UCR-2097, REV.0 1

REVISED PER UCR-2093, REY, I AND UCR-2094, REV, 1 DATE NO.

DESCAIPT [ON REVISIONS APPC.

REFER TD !JfAWING MICROFILM OR MASTER IrtlEX FOR APPROVAL DA TES AAD SIGNA TUlES. ICADO-RASTER>

  • THIS DR.A\\IING IS Tt-E: PROPERTY <7 THE AMERICAN ELECTRIC POWER SERVICE CORP. APCI IS LDAIED uPON CONJITION THAI IT IS NOT TO 1!E REPRODUCED OR COPIED, IN IIHOLE OR IN PART* OR USED FOR FuR*

8 NISHING INFORMATION TO ANY PERSC:11 WITHOUT Tl£ WRITTEN CONSENT CF Tl£ AEP SERVICE CORP.,OR FOR ANY PUIFOSE DETRU£NTAL TO Tl-£1A INTEREST, AtCJ 15 TO 19E RETLRNED LPON Re:QUEST*

INDIANA MICHIGAN POWER COMPANY DONALD C. COOK BRIDGMAN NUCLEAR PLANT EMERGENCY CORE COOLING (RHRl UNITS NO. I & 2 MICHIGAN DWG. NO. FSAR FIG. 6.2-1A & FIG. 9.3-1 9

ARCH ELEC NECH SIR tlCM.1!1*

DESI* EIIGINEEIIINI DIYISDII N

AEP SERVICE CORP.

1 RIVERSIDE PLAZA COLUMBUS, OH 43215 0

FSAR FIG. 9.4 - 1 SPENT FUEL PIT COOLING & CLEAN-UP UNITS NO. 1 & 2 VALVE POSITIONS ARE NOT GOVERNED BY THE UFSAR FIGURES BUT RATHER BY STATION PROCEDURES (EXCEPT VALVES WITH LOCKED OR SEALED, AND FAILURE POSITIONS AS INDICATED).

3.

UFSAR Revision 30.0 5

6 7

8 9

A B

~-16'!)1::I lllfS::f *oN -~Ma VENT TO DRAIN HEADER /

SEE FIG. 11. 1-1_,,

DEMit-lERALI tE:D WATER A

B C

D VENT°"

C D

E TO eves HOLD-UP TANK SEE FIG. 9. 2-4 F

REFUELING WATER PURIFICATION PUMP SEE NOTE 2 SPENT FUEL PIT PUMP SEE NOTE 1 G

H TO COMPONENT COOLING SYSTEM. SEE FIG. 9. 5-1 UNIT N2 I UNIT N2 I J

K FROM COMPONENT COOLING SYSTEM. SEE FIG. 9. 5-1 SPENT FUEL PIT HEl'sT EXCHl'sN<;ER STR/1.INER~

L FROM COMPONENT COOLING smrn. see e,s. s '7 M

r TO COMPONENT COOLING

/

SYSTEM. SEE FIG. 9. 5-1 SPENT FUE.L PIT HE.AT E.XCI-IANCiER SPENT FUEL PIT SKIMMERS ~

SPENT F'UEL PIT SKIMMER. F'ILTER FROM eves HOLD-UP TANKS RECIRCULATION PUMP, SEE FIG. 9. 2-4 SPENT FUEL PIT PUMP SPENT FUEL PIT OUTSIDE REACTOR CONTAINMENT INSIDE REACTOR CONTAINMENT

?}//1/7 DEMINEKALllEC


i~-~~-~~-----::=====:==---------1 WATE.R ---

F.C.

F.C.

N 0

NOTES:

1. ONE SFP PUMP AND HEAT EXCHANGER NORMALLY IN SERVICE.
2. REFUELING WATER PURIFICATION PUMP ALIGNED TO UNIT 1 RWST VIA THE SFP DEMINERALIZER.

OTHER LINEUPS PERMITTED AS DESIGNED.

REFERENCES:

OP-I <21-5143 OP-I (2)-5141C 3

5 6

1---4-1---------L-.I 7 REVISIONS FILENAME:

har-fig-9-4-1.163 (raster file): fsar-fig-~-4-1 163.cit

~

FROM REFUELING WATER UNIT Ni 'Z. ~

§rnR~rt tf-\\

TO REFUELING WATER STORAGE TANK SEE FIG.6.3-1 REFUELING CAVITY "THIS ORAWINU IS THE PROPERTY OF THE AMERICAN ELECTRIC POWER SERVICE CORP. ANO IS LOANED UPONCONOITIONTHATITISNOTTOBEC;REPROOUCED TD RWST HEATING PUMP~

-VENT (UNIT NII I) t----+--{Ml-----4--j I-..._ __._. TO REFUELING WATER SEE FIG.6. J-1 SPENT FUEL PIT DEN\\INERA.Ll'Z.ER REFUE:LING, WATER PURlf-lC!s-TION FILTH,

~

TO SPENT RESIN

'------~HI------.,,-

STORAGE TANK SEE FIG.11.1-2 TO DRAIN HEADER SEE FIG.11.1-1 E

CM 1 2

4 5

G

\\sINCH 4 H

  • TO DRAIN HEADER SEE FIG.11. 1-1 12 16 D[MIN[RALll[D WATER.-----+--~

J STORAGE TANK SEE FIG. 6. 3-1 (UNIT NS!2)

F. C.

F.C.

L.C.

L,C, 30 L

REACTOR VESSEL T N2 I t:ail

/

l<.E.ACTOR VESSEL UNIT N2 2 M

TO REACTOR COOLANT DRAIN TANK SEE FIG. II. 1-1 REFUELING CAVITY TD REACTOR COOLANT DRAIN TANK SEE FIG. II. 1-1 N

OR COPIED, INWHOLEORINPART,ORUSEOFORFUR-NISHINGINFORMATIONTOANYPERSON\\IITHOUTTf-E

~RITTEN COIIISO:NT o.- T-E AEP SERVICE CORP.,OR i:cQRAt,,iYPURPOSEOETRIMENULTOTHEIRINTERE.ST, ANDISTOBERETURNEOUPONRE0UEST" INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT DWG. NO.

~

MIIRJ'C'JIN KiCTRIC POWER STR AEP SERVICE CORP.

1 RIVERSIDE PLAZA COLUMBUS, OH 43216 0

8 9

fsar-fig-9.5-1_22.1.dgn 07/29/2009 10:58:13 AM UFSAR Revision 30.0

+

+

1 2

3 5

6 A

I L-S'6 *01::1 l:IVS::l 'ON "OMO

'CF!'

J *

(2) RESIDUAL HEAT REMOVAL PUMP MECHANICAL SEAL HEAT EXCHANGERS OIL COOLER (TYP)

B CF!

CF A I

C J

  • I I

I

' CF I I }

D

' I II (2) CONTAINMENT SPRAY/

PUMP, MECHANICAL SEAL HEAT EXCHANGERS---

  • l I

,,)

,J I

I' 1

~ ' 1 I

I

.I I~ '

a.

A 11

-I r"'

.. lll-lll-CX.:t-... lX,-.~.. lia.. _.. _____ _.

' I, IGi\\

\\.J BEARING OIL COOLER (TYP)

-OIL COOLER (TYPl

~

(2) MECHANICAL SEAL, HEAT EXCHANGERS i (TYPl i

I E

l

/

10 FL.OOR I --.

u,*--~(2) RESIDUAL HEAT IY-

__..1 EXCHANGERS I

F r

I G

I H

I J

"'" \\/ENT Ii OVERfL0W

\\JAC(JUM BRE).KER.

. ~

I

~

r A~

  • A

~ TO DRAIN HEADER

,o FLOOR

..., tEC.

SEE FJG. ll.1-2 DR~IN----

..,.......---COMPONENT COOLING

/

SURGE TANK J_..

~~~L;-A--l

~

.---t-il

...... t-,

T I

I I

'--.J

~ct I

l'\\.cHEMICAL

~

CHARGING TANK

.--f:

.... ~.* __ __,, ~.._ _

_., "-..__-i:_c_.___, * \\

I DEMINERAL~

+._ -

F-OR ORIGIN WATER

~..

SEE THIS DWG E/6 j

I

' I LCfR\\ fCTA\\

...1!1-,.,P-..

-... '9

... _*y

... ~ ~'-I 1

7

.-,--,-----r--....,...,r+

'CF I'

-r..

~

SEE NOTE 2

. tCRs'I LCRA),

(2l COMPONENT COOLING HEAT EXCHANGERS TO & FROM ESSENTIAL SERVICE WATER SEE FIG. 9. 8-7 (2) CENTRIFUGAL

/'

\\..._,/

L_ (2l SAFETY INJECTION PUMPS 1'---TO RCS

~ FROM RESIDUAL CHARGING PUMPS__/ -,--;::;;-"T-"'*-----~~----------*----

HEAT REMOVAL PUMPS

}

.,.cFi',

{

SEE FIG. 6. 2-!A I

TO OTHER REACTOR

~

FROM OTHER REACTOR I ** COOLANT PUMPS

,~

~

COOLANT PUMPS COO~E!i-

      • l -. -

{m\\

OIL

/

-LOWER. GUID-E -

BEARING COOLER

~

(4l REACTOR

~

CF!

COOLANT PUMPS rr;.r,,,,;;

I

!'CFA

{'cri;\\

,.o,i

  • P-<7 I

--~

T

>,.,I __ y I I

,_ :z:

z L.LJ L.LJ
c l\\'1---t.~==:;

f

~ ::

,_ :z

z:

0 8 u A-

--~---

A r:.F.,-

~-..

,-TO COMPONENT COOLING

, SURGE TANK, CHEM FEED

    • SEE THIS DWG J/2 r

~

c.:

0 0

c' I

l I

,srr FJG. 9. z-1 r*

LETDOWN l.,

HEAT EXCHANGER SEAL WATER 1

HEAT EXCHANGER

....____,\\.

'-----"~SEE FIG. 9. 2-1 I(

=-1.. ~*.,:l)~K),-,c0**a-,{"'.;""",....

  • THERMAL ~

!JOA)

TO & F 0ROM REACTOR

-;,._ -*~.-

BARRIER-

.1 SUPPORT.COOLING

    • i--.-cl**~~,A_;b+*-~~=

~

t,.J F.C **

-EXCESSLETDOWN

'---1),,_.

1 --~

SEEFIG.9.2-1

~ u,----~--~~..-1*11-*,----.. --.. -------..... -------------£8*3'-*..

< ;:s

~ *

~I""'

I

  • ~

L.LJI~

TO '111\\SIE GAS re-_

TO~ FROM ~ASTE GAS COMPRESSOOS. SEE FIG. 11.1-3 I

,fFA" I

HEAT EXCHANGER"

'"C.4 V

CFA

~ ;:;;

C.Ff COMPRESSOR

o

't l '

z: S "'LT.

SEE FIG, 11.1-3 ~

FLOOR..---+----------"---,

I L

I@)

\\.

7

~ -.

I I

TO UNIT N91.

.am

'CY (2l COMPONENT COOLING PUMPS (ll SPARE (UNIT t) ONLY>

M

' Ir I

N I

0 CROSS-TIE

~FROM UNIT *2

-ti----

NOTES:

1.

BOTH cc~ PUMPS AND HEAT EXCHANGERS SHOWN IN S1:.RVICL VALVE POSITIONS ARE NOT GOVERNED BY THE UFSAR FIGURES BUT RATHER BY STATION PROCEDURES {EXCEPT VALVES WITH LOCKED OR SEALED, AND FAILURE POSITIONS AS INDICATED).

2.

CTR IS UPSTREAM OF ISOLATION VALVE FOR UNIT 2 HEAT EXCHANGER HE-15W ONLY,

REFERENCES:

TO & FROM

~-SPENT FUEL PIT

+.

A i -

7

~

'r OP-1 OP-1 OP-1 OP-1 OP-1 OP-1 OP-1 (2) -5135 (2) -5135A (2) -5135B (2l -5135C (2) -51350 (2l -5135E (2) -5135F

z:

0 SEE FIG. 9.~

TO FLOOR I SPENT FUEL PIT HEAT EXCHANGER 6,.c.: -..

I _e,t I

,,~.

UNIT *2 ONL y_/* *,-..._-----,

r------------~L_J.9.

1

.9 1 __

I CONCENTRATE COOL ER I

DISTILLATE I

COOLER I

I I

I

~

z 1

2 3

t--

1--

5 f-6 t--

7 l

REACTOR...

7 '

  • 1 1.~,-"'------+--,,

1/

FROM OTHER{ _

'f COOLANT 1-..._

~ o RE'T'U7,

\\,_,J ~ l'LDl!l /cil\\

'\\_

--;---i---------i--- 7 8

I

,I

.i'i" I

PUMPS F.(.I TO SG BLOWDOWN SAMPLE COOLERS (4) --

~

~r.~orROM PENETRATION L

--- ~

_ \\._~l~G C~IL !TYPl ~iot::><>9~-.... --__.__

k

\\J +-,l,~=1~=1rroiww~A S~TiFE'GG AA's;--' ( 2 l WASTE GAS COMPRESSORS

~--=~~t,-r::,._~l~:;:.---r:.:.:,..._"":.,..

~-~=---~--l"-111,'..

~....

COMPRESSOR HEAT EXCHANGERS SU""

i,.-TI..LLT,,,_\\J;.

SEE FIG. 11. 1-3 (UNIT 1 1 ONLY)

.-,LY-L.c:.

TELlTIILE

~- -----.. --------*~-----*----------------.. ~-------*-------

~

'--.__AT UNIT *!-ONLY

--1\\TUNIT l-.lliONLY7 _

I r,--~-~UN_fr..

M!*2*":l:J.--*------.;-,1--.. -------**.p-~-P-OS*T-AC*c*ID*E*N-T *u-ND*I-LU_T_E_D -L*IO*u*ID-.. --------!!~!!!

ONLY SAMPLE HEAT

,-1 l,nl /4n' EXCHANGER

,t1.,.r_--.--,

~

1

~ _

CONDENSER

~ROM SG BLOWOOWN SAMPLE COOLERS(4J,..

/CTI\\

'.> 1--,c;,,._...

-*-1*><1*_~....

~

/AT UNIT *1 ONLY

__ rCAP

~;~~---~~~~::::.:==========~~

~~~----.. --------~--*-~

~

OUTSIDE

'CFJ',

-, :.-_ r -TO LLfil)_R _____

":1'7 (m\\

~ -

~ '

I

,_"f'~

  • ~, * : \\....,../

0, 11 I

'CF I, - -. _,1 t V f I C

---TO REGENERATIVE

~

F.l.

I

\\

~

r-*

HEAT EXCHANGER I

SEE FIG, 9. 2-1

-FROM VOLUME CONTROL TANK SEE FIG. 9. 2-1

, CF I

' 7

< I

._ ___.,___ ___ _.l, [

~ rCAP

,p

,... ___ 1

'v TO P.. FROM POST ACCIOENT

\\

.. SAMPLING SYSTEM

( U 2 0 NL Y }

9

_, ___ INS_IDE_CONT~=-- --- -- 1-- c.::---J I '-EVAPORATOR I

I ~~.~

CONDENSER

'. I I

1 DISTILLATE COOLER7 I

V PUMP BEARING OIL COOLER I

TO.AWD FROt.A C"tHE:R.5.. Ml'"LE:

Hl,t,,T & 'iC.Hi.Nl!i!115 TO AWO ¥ROM OTH!ll 'SAMP'LI rl!At.T l!:XCM._WGU'!i

.. '\\_/4 I( FROM A!F\\

H ~

REC.I RC..~,., SKIMMER hAN. kaTOR (T'fPIU..L)

  • ~

I I

I I

I I

I I

VENT I..,...___..

..__,__ ____ ___.( CONDENSER I 'i.~.------------.-.,,-

1 BORIC ACID L_..:. ___ --- _Ev~ 0 RA ::..9_R ::'L ____ J, ______

R E_C_I_P R_o_c_A_T I_N_G_C_H_A_R G_I_N_G _P_U_M P_-""7.c_._J COOLER,-~ r-----i,.1ii..

  • -t

__,~ II I

I I

I I

I I

I I

IGS069.tl A

B C

D E

I CM I 2

3 t-4 s

6 7 I

,....--+-{CTT.\\c_T_T.-,

_;--....i.... ~

/cr:f\\

~,\\

~~-- J

. ~*... *..........

1111

  • .)~*(X~~Ji-.*I,,..~SAMPLE RACK SAMPLE RACK G

~~

I~

~~

\\~---- SAMPLE EXCHANGERS <TYPJ I

I H

'12 116 J

L N

22, ( REVISED PER UCR-1938, DATE NO, DESCRIPTION REVISIONS FILENAME:

fsar-lig-9.5-1 22.1.dgn (raster file): fsar-fig-9.5-1 22.1.tif APPO.

THIS DRAVING IS THE PROPERTY OF THE AMERICAN ELECTRIC POWER SERVICE CORP. ANO IS LOANED l.l'ON CONDITION THAT IT IS NOT TO BE REPRODUCED OR COPIED. IN WHOLE OR IN PART, OR USED FOR FUR-NISHING INFORMATION TO ANY PERSON VITHOUT Tl£ ltRITTEN CONSENT OF THE AEP SERVICE CORP., OR FOR ANY PURPOSE DETRIMENTAL 10 THEIR INTEREST, AIICl IS 10 BE RETURNED UPON REQUEST" INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT BRIDGMAN MICHIGAN COMPONENT COOLING UNITS NO. I OR 2 DWG. NO. fSAR FIG. 9.5-1 ARCH I I ELEC SCALE**

DATE:*

DESIGN ENGlt.t:ERIMG OIYISION1

-~

I MECH I I SIR I AEP SERVICE CORP.

1 RIVERSIDE PLAZA COLUMBUS, OH 43215 0

8 t--

9

UFSAR Revision 30.0 1

2

+

3 4

5 6

7 8

9

+

A I

L-9'6'91~ l:IVS~ 'ON 'OMO Unit 1 only MSX\\.T

. ~-...,I I FROM MAIN STEAf.1 LEAD SEE FIG.

10. 2-1, 10. 2-lB I I A

F.C.

I I

B I

C TO NUCLEAR SAMPLING ROOM I

0 f

', Ii,..........., '-.._,,I rom

'J I i I

I

'. r--'f--,

E fA I

F I

G I

FROM COMPONENT COOL ING SEE FIG./9.

5-1 7 <~:~

I ICE~'l,e(;::>F<)A..... -...

\\.

j

-SAMPLE CO UNG C _ _..

COtL. TYPE. TYP)

OT!'

r-TO COMPONENT

/i COOLING SEE

,,/

FIG. 9.5-1 H

I TO STEAM GEN.

SLOWDOWN TREATMENT PUMP SEE FIG.11.5-1 J

TO F'LR 011.~IN I

r-

  • I I

I I

K I

I I_ -

___ I I

L I

SAMPLING, SIMI HOOi? 7 (Typical for all sample

/ ~--- Connection!, except Steam Generator. lowdown).

t.

V -TO UNIT Nq, 2 SINK

~ DEMIN. WATE ~

M I

N TO BLPG. EXMAUST

/

VtNTIU.TION SYSTE.M UNIT N'ii 2 SINK CStt.11U>.R TO UNIT Nill

,-0 DR,i,lN HtP.PER Fo R CONT. ':> EE ii-ii, OWCi. 12-L./~

I

REFERENCES:

OP* 1 (2l*Sl 41 OP*l (2)-5!41A OP-'. (2l*5141B OP*l (2l*5141D NOTE:

0

\\

SKlTCH II M-4

  • SAMPLING SYSTEM SHOWN IN L----------~------11-------~~W~W.;IR~A.UC~K-;-'~' S~RIIDY ----........... ---+--------------F-ROM. DEMINERALIZED-1 E ~Cl.O$ED SAMPLE. SINK STANDBY ALIGNMENT.

1 2

3 4

ACCUMULATOR SAMPLES SEE FIG.6.2-IA 5.l\\MPLINq

~

WATER FOR !=UJSHING

'--------+--------------------:-;VALVEPOSITIONSARENOTGOVERNEDB THE UFSAR FIGURES BUT RATHER BY t-FROM LETDOWN LINE rji::.:,Q.... $;;:::X\\:)-~--t'Nl!jlilt._., *..,.~---------------.J.

/19, STATION PROCEDURES (EXCEPT VALVES

,.. ____ ~ ~--

AT DEMIN. INLE~~

. 1

  • WITH LOCKED OR SEALED, AND FAILURE

/rsx\\Ll5X:').

r<;,;,(~_

1sx':).

SEE FIG. 9. 2-1,

\\,____,/ I POSITIONSASINDICATED).

'I,.-

H l

\\

~

TO SAMPLIIJC::. SINK.

'\\.._,,_,7,....._...,I \\--.....,1 _..,1 FROM LETDOWN LINE AaQs;::x~,\\~,+ol --iLM.M~!*;,;.:**_-_-_,_-_-_:*.-_-_._:-.:-_:-_-_-i:*======......==~=~~=;t:==========t===~i-;._-_-_-_-_:*.-_-_--~i:-_-_-_-_-_-.,1-,-*---~-=-==*=*=*=*=*=*=*=*=*=*=*=*=*==*=*=*=*=*===*=*==*t*:*:*:*:*:*:*:*:*:*:*::*:*:*:*:*:*:* ~""!~:::~:~ ~ :'JEE SK, "M*4" r+

I Af OEMIN. OUTLET...........,

7

, I

\\

~

r L.>,.

C SEE FIG. 9. 2-l __...


.... ---------**.....__.=J Ft*L*.F~.2"'~-,*..;.~~(}-c_,.L.....

(}-..... F~-*-*-...... 9 *. i---------~-*~~'.9~,~~---*-* ________ ~... ---+~-1------r--~~*:--------4*r-----~-----~~~~=~-rllllllllj*~:~*~,-----~ -.

a F.C.

. l.

/'\\ I

£,FROM PRESSURIZER STEAM SPACE SEE FIG. 4. 2-1

'<}-

/N $X\\

.'T\\ '

J-f F.C.

L~ROM PRESSURIZER

'LIQUID SPACE SEE FIG.4.2~1

. I TO VOLUME CONTROL 1

. '?.F-~~

T :c.

TANK SEE FIG. 9. 2-I TO POST ACCIDENr I

SAMPLING SYSTEM SEE FIG.9.6-2 ____....--.,,,

L FROM VOLU~E CONTROL TANK GAS SPACE SEE FIG. 9. 2-1

. 9 I f,C, I f.C,


.1 TO BLOC,, r.')( HAUe. T VE.NT SY!:>TE.M, -------

I

'TO VENT HOR

  • SEE FIG. 11. 1-1 I

IP

  • r 1

CAP 1'1'7\\

~

TO eves HOLD-UP TANKS

.*.: L,~

I I

I I

. r

-+---:.:.

.,,ri.*

_f---1_

POSf ACCIDENT UNDILUT~D Fl!OM u>.11T.):). i-/

REACTCR COOLANf SAMPLE' FROM HOT LEG LOOP 3

\\ SEE FIG. 4.2 -1

\\

r----K: (}--

LN S_:0-

!i~

l

'\\,.__,7 F.C..

\\DECAY

\\ COIL.

\\.....,__,/ *

  • F. c:

L FROM HOT l.EG LOO? 1 SEE FIG.4.2-1 I

I I

~*

8 cC ~

-1} ~

z J '-"

TO POST ACC!DEN

a. ~ I UNDILUTED RE-

~ I fC '\\ ACTOR COOLANT Ul

s;;

SAMPLE SEE

<C *SK "o-7"

\\

FRO.. M RESIDUAL HEAT

~I u1 REMOVAL LOOP ii ~

  • SEE FIG. 9. 3-1

~, Ji

.?,.?~.?, 0

~.

.?,

F.C.

F.C.

TO POST-l'.c.

ACCIDENT 1

~

SAMPLING

~~

C?~ -~:-,

. I. /

'/

I I

.... "I'------=----,,......

I

--Sl>.MPLE HEAT E.llCHA.NGER COIL T'iPE (TYPICA.L)

'-. TO COMPONENT COOLING '~ATER SYS SEE FIG.9.5-1

9. G-2C, ->....._<::)Ii/_ --~--1 C,

_,-,-... 0

~-

F.C, F.c.

!i.. '1\\PLIKG itlCK *~11

.l "Ill' l

/IPI

...l.

t r

I 6

..J.

'ttPl\\

I rl

,- PWSU~IZ.Ef:?

H LIQVID

~PLi Y!S1EL.

.... I-ln,f

,,.,-VOLUME.

CONTlc :IL TANK 5AMPL*~

Vi5~£."

a

..--l=ROM \\t.ll.,\\C.L.I..A.R $Af,,i\\flt..ll\\Uit "btNK.

>E>IS TWI"' DW<,, I!' N/4,

_/VFltOM Ut'IIT ll=Z 1 * }~v-FROM "POST ACCIDENT SAMPLING SEE FIG.9.6-2 SKETCH "0-7" 9.: REVISED PER UCR-1746

  • DATE NO.

DESCRIPiION REVISIONS FILENAME; lsor-lig-9-6-1 19-3.dgn

!raster Iii*): fsor-lig-9-6-1 19-3.lif

APPO,

THI$ DRAWING IS THE PA:OPE'.RTY OF THE: AMEJQ:CAN ELECTRIC POWER SERVICE! CORP. ANO IS LOANED UPON CONOIT[QN THAT IT IS NOT TO BE REPROOUCED OR COPIED, IN WHOLE OR IN PART, OR US£D FOR FUR-NISHING INFORMATION ro ANY PERSON WITHOUT THE wRITT£N CONSENT OF THE AEP SERVICE CORP., QR FOR ANY PURPOSE DETRIHENTA~ TO THEIR INTEREST, AND IS TO BE RETURNED UPON REQUESTN INDIANA MICHIGAN POWEii COMPANY DONALD C. COOK BRIDGMAN NUCLEAR PLANT SAMPLING UNIT N0.1 OR 2 MICHIGAN DWG. NO. FSAR FIG. 9.6-1 ARCH I ELEC SCAL£l ORI DATEI DE8l8N iNOlt£ERlNO DIVlllON&

FRCM RESIDUAL HEAT

_,L~.I;:S<x\\:)l....... ?.~

?,~-t>-.,..'---~- FROM COMPONENT

}-TO DRAIN HEADER REMOVAL LOOP ----------\\-__...,1..

.. 1..,

COOLINO WATER sys 1 ~sEE FIG.11. 1-1 a.,~...

SEE FIG. 9. 3-1

\\_

F.C F.C.

SEE FIG. 9. 5-1 a.---------.---------*1!11111--------~1~---------,,,---------"P-*-C=f**::c:r*:q:

  • r;,p,,
    :i,;::r:,:p,*:::r;:rr-----~----r,:;:::::;::.=F*::;:::.: *:r:-u~

-~:.::3::f -~----:~---~::;:;:;::;:;:;::w:i*::w~

  • i.uF:i:J,.::;::;:;:;:.,~.----~----i==*~*~L*'F*:r:::; *t2*=fI:C:ci1~3-----:------r1 AEP SERVICE CORP.

1 RNERS(DE PLAZA COLUMBUS. OH 43215 10s0694 A

I B

c D

E CM *1 2

3 F4 5

6 7 I G

1316 rNcH I4 H

112 I1s J

lrENTHS 110 K

120 130 L

IJNcHES 11 M

12 N

0 5

6 7

9

FSAR FIG. 9.6 - 2 POST-ACCIDENT SAMPLING UNITS NO. 1 AND 2 NOTE:

VALVE POSITIONS ARE NOT GOVERNED BY THE UFSAR FIGURES BUT RATHER BY STATION PROCEDURES (EXCEPT VALVES WITH LOCKED OR SEALED, AND FAILURE POSITIONS AS INDICATED).

16.5 Revised Per UCR 98-UFSAR-0793 16.5 UFSAR Revision 30.0 A

2 5

6 8

9 A

8 C

D E

F G

H J

K L

M N

D

,.f,C-T().f. C.

Q,$, C. T, *. c.

I FROM UNIT I FROM fJN1r 2

~tf,ft'l~..,...-+----**---1*1----------------C:>1------------------------------.. ------------------------K:J---------------------t*t-----tlllll----+~....____'l3/4f1'tffT F.C,

c, DEMINiftAL it£ D WA.i£.R RI Tl.JIU,/ -ro I.JN!T I CONr,,,,IN/tll&Nf 8

FROM NUCLEAR SAMPLING SYSTEM FIG. 9. 6-1 F.O.

F.C.

FC.

FC.

C FO FO FO FROM NUCLEAR SAMPLING SYSTEM FI G. 9. 6-1 D

FC.

FC.

E ARGON GAS C,ALll;JRA.T10N F.c NtTFlOGEN

<,AS (2) WA~iE. C.Ol-LE.C. TION TANK OISC.HAP.<.i,C PUMPS F:C.

CM l 4

5 6

N I TROGEN GAS TO & FROM COMPONENT COOLING ~ATER FIG. 9. 5-1 POS T ACCIDENT LIQUID AND GAS SA MPLE PANEL SEISMIC CLASS 111:

Cl WASTE C0LL£CTI0N TANK L.C.

\\ 6 INCH 4 F,C.

H 12 DM1NERALll WATE.q NJTP.06£N s

PH CAL18RA. TJON SYSTE:M O,i CA£J8MTJO/t,/ S~TFM F.C.

r:c FC.

J F.C.

F.C.

OEM;JvCRAL !ZCO WAT£H TEITTHS 10 K

20 FROM NUCLEAR SAMPLING SYSTEM FI G. 9. 6-1 F.O FROM NUCLEAR SAMPLING SYSTEM FIG. 9. 6-1 F.O.

FO F.C.

r.c..

F:C.

O.&'iAt# ro WAS7£ t)1Sp,:)!:,,'f',. P"l-"f l/v Hi;,Ai,;JER 30 L

l NCHES FC.

M FC F.C.

F,C, li'f!TUtlN 'T"C:, U,-M T 2 COIJT'A.IAIH~J.JT N

5

REFERENCES:

OP-1 C2l-SIUD 6

0--+--i---------+---- 7 REVISIONS FILENAME; hcr-fig-9-6-2.163 (rasler fil,): ha,-fit-9-6-2 163.,it

  • n us ORo\\llitlG IS TIE PROPERT,. CF TT£ AMERICAN ELECTRIC POWER SUVICE CO.. ANO lS LO,.,NED UP-ON CONDITION 11,.U IT I S NOT TO~ IIEPRODVC~

~~~::~~:":7i~ ~ :~/~v~ls:UT~N;uR-a WRITTEN COJ,ISENT OF" II-£ Al!P SERVICE CORP., OR FOR ~

PIJ1:POSE DCTRll'ENl.o.L TO THEIR OOEIIEST, INDIANA MICHIGAN POWER C0"'9ANY DONALD C. COOK NUCLEAR PLANT BRIDGMAN DWG. NO.

ARD<

--KAN

_,,,RRTRK' l'OWIR MICHIGAN STR AEP SERVICE CORP.

1 RNERSIDE PlAZA COLUMBUS, OH 43215 0

9

UFSAR Revision 30.0 FUa TRANSFER SYSTEM CONT(TOI CII WIKQl.

l<Ol'IJt atna, ~mm, SParr!=UEL STORAGE POOt.

  • j 1 *

,~---CDff(TOR ch.

WIIQI CABl..

i stCTIOll A-4 Jw.yl9131.

UFSAR Revision 30.0 c..

C I,

~

~..

A1 13X14 C1 13X12 E1 13X11 A5 13x14 B1 12X14 D1 12X12 F1 12X11 93 12X14 Typical Radc-to-Aadc Oap: ~.

C 58'*31/8.

82 12X14 D2 12X12 F2 12x11 84 12X14 A2 13X14 C2 E2 13x11 H

13X14*8X2 A3 13X14 C3 13X12 E3 13x 11 A4 13X14 C4 13X12 E4 13x11 Total Storage: 3616 cens (Include 3 triangular comer cefts)

FIGURE 9. 7-2 : COOK SPENT FUEL POOL LAYOUT f

I r z

4 16'

  • The storage pattern for any of these individual modules may be as shown in this figure or Figure 9.7-4.

Title:

NORMAL STORAGE PATTERN (Mixed Three Zone)

Sheet 1 of 1 UFSAR Figure: 9.7-3 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN Change

Description:

UCR-1961 Revision: 23 UNIT 1 UFSAR Revision 30.0 REGION 1 CELLS 0

REGION 2 CELLS 121 REGION 3 CElLS

  • The storage pattern for any of these individual modules may be as shown in this figure or Figure 9.7-3.

Title:

INTERIM STORAGE PATTERN (Checkerboard)

Sheet 1 of 1 UFSAR Figure: 9.7-4 AMERICAN ELECTRIC POWER COOK NUCLEAR PLANT NUCLEAR GENERATION GROUP BRIDGMAN, MICHIGAN Change

Description:

UCR-1961 Revision: 23 UNIT 1 UFSAR Revision 30.0

  • MODULE A1
  • ,iooDCE C1
  • MODULE E1

~

  • MODULE 181 EMPTY LOCATIONS REGION 1 CEUS REGION 2 CELLS
  • - *,'.l'. ** *... :- ** :- ~-

r'.; ::.**

-r.-* ::: :*: :: ~: ;:_ ~:~

-***,I':-: *-,.;

. : :- **. ~- :-: :-. :-:

. :..-.. -~ *.... :-*

-: *"-.'.*. :.: :x:-- >-..

REGION 3 CELLS

UFSAR Revision 30.0 u

u a

ElSOOOl----i--4---4----4--~~-~---..~~-I

~-

!30000~---4---4---4---+-'-.J-~~~-~

C:

J

~~000t----+--_.,__.....,__.,,.-+--~~-;-----1,-_-'

5 INITIAL ENRICHMENT, jgU-235 F I GURE 5

  • 7-5: ACCEPTABLE BURNUP DOMAIN IN REGIONS 2 &, 3 July 1994

...\\fsar-fig-9-8-1_18.dgn 12/14/2017 12:59:20 PM UFSAR Revision 30.0 1

2

+

3 4

5 6

7 8

9

+

A B

C D

I-8'6'01.:l ~VS.:l * 'ON -~Ma DRUMMING AREA, TRUCK LOADING AREA AND SEE THIS D

J/1, PERSONNEL ACCESS WAL'tCJ/VAY AREA DRY PILOT DELUGE VALVE f Pl.ANT CONCIIE.f!

IIIOIJIIIALl;l tL0H D MOctN* !tLPtii AUTON.IT

  • VE IGS0694

..- Ill fNII 7"-11, ~

II: 11,/,,ttl'. 1)11" PIU)T 0e~UC,1!: ¥~~¥1-

"---FLUINDUT NEW fl'UlL lfCf.lVING Al( A o~v IO'II.OT

  • DI~ U Cl!* VI.LVI ICE>' PLAN*a*

F1*1. PROTECTION PIPIN6 IN AU#fLIAlt1 IUILDIHa

'IIRV1e1. eulLPIN8 HYDRANT OFFICE &UII.PIN&

FLUSMOUT(TYP>-t-.._.

!RNOTE7.

mNDlll.a/4 SIINtn.. QM, SIENOTEIO.ct/1 SEINOff 11..0/3


o CIITIMtlFCIIMD ILI.GTIIC PE.LUfti YA\\.VU NU.Tl.* M't UNIT Nel r HYDRANT Sll!l'ollil<IN ~51111!.'> l'OR MtSll!Kt 11,11110 1 UllolTa.Hll,\\!;1,1"1' RC:11' " C:11,\\III.C:Qili,I. F11,,Tblll$,

CA.!il.11 TUI.I~,,iO$!: Rll:!1.fi, AIIK IY.0Gi e,a-,; -.0~ i 4oM 1 Pftl:A.c.TICl t.l tll'IILl~l.!:~,C1l:.ILI. !!IQ PIIM" SP"lll,ll(I.E:~8 1 TUI-I *uPfltoA.T !PRl~Kl.*R.

CHAAtDAL, 1'11.Tt.R, 1,1,~1c.* !al,,~ i-lU.Cl*I\\.,.,MIii

~ 011~101!: l.0019 1,11:,W OFF ~1.0(li 5,PFlri.i,..1.1:ll, STl:IFU:IWO~

1'a.c.ll. !iPR,11,Ul,1.e:R~, r*1111c. l'M~

81111.1111-lli !'IF'ltlt,11, ~ilol. el.,,.TE~, C.Olollolll!C. 1'1 'lN& TC 111'1"' t. llil.. TSII! ':l'T"'III,, -1lf TAN,<!, 1 FIii I PUM ~ CE:'TJ.

_. 1 Ml!IC M<lbl '1',T<l,,-lt),J A'JDIT, I~...

A B

C D

E F

Dlff PILDT MLVE __,,,,

MIIIIMDU!IIS~

FCAM.CCltlN.

"1111 C.ONTAINMENT UNIT NO. I fROM f'UMP INTAKI C..H-"M.U G

DRY PILOT VALVE TSC/NAB BUILDING I I ru&L MANDLINGi A IIIA. I I rf,uNT I I J

ICIV PLAN*"A" TO AUi. lUILDINe IEE IClf PLAN"I" C.ONTAINHtNT UNIT NO.I CONTROL IIOON ClGIITIDL IIOOM UNIT N* I UNIT NII UNIT I

  • I(

L HYDRANT-,

'T"Milll'CIRMIIPI IILkT"IC

~l~u~* ~M.YI:

TRANSPOAMlll D!C.K C6J TINIUORM&R 11.lCTRIC PIU,*I YN.Vl'I FWINaUf (T,RJ 111-.,11 **v UNIT NII H"l'DRA"AT ENGINE DRIVEN PUMP

==*siT*R'a:MHtlUltiiR!----------;::-:::::~ ---""'4 -------'

ABANDON IN PLACE NOT AVAILABLE FOR SERVICE E

CH I 3

4 5

6 7

G 316 INCH 4 H

12 16 J

TENTHS ENGINE DRIVEN PUMP ABANDON IN PLACE NOT AVAILABLE FOR SERVICE 10 I(

2D 30 L

INCHES M

1 M

N TRANSFORMER ELECTRIC DELUGE VALVE ENGINE DRIVEN PUMP

--..IAIBANDON IN PLACE PtJt,f HIJ.JSE FROM FIRE VATER STIIIAGE TANKS 2

3 N

0 0 DEN0TH. FIi" MOSf CONN F AB WAREI-IOOSE ACB NOTI! Ip 1/S, 1(/S Mfil. GEN fND SPR:lt.lkl.!ft "'-~lo\\ VA..111:

NOTI! 'I, F/5, K/S' BAS&.M£NT GE'M END SPR,1,11(..1,i-o\\\\,l,"M,-'I.I/II NAIi 4,,1s *.J/5 8A5fM!'NT TIJIP61NE ~NO Pli='II.IC'ii !P1111i..r'-i...i.._,1,,RM

\\IAL. ',j I!:,

NGTI Ir ~IS. J/S AtlX\\1 1... "t PIID PUMP SPRIIIAIR Al.MM VALW.

NOT! I* CIS SIRVlC IM..DG. IPRIMICI.IR

,&I.NIM VALVE Mptg i C/5 0PFICI 8\\DII. SPR'INIC.LliR ALARM VALVE.

NOD It C/Gi

=ir.. Sl'i:'1~~ w.vr.

~OJI I, C/r.

AUX, &01\\.IR Sl'RIIIIK\\.I" ALARM VALW NOTE 10, CJGt 110ffl.l SHID DELUCII YA.LV HAIi !\\t C/&

OPFICI BUILDING ROA.0 OVIRMANG CIILU(H VH.VI

~l.i 1ili'6

'~~~~ ~l~I ~,

!PAINKI.E:R ol\\1.A,IIIIM VA.LV*I N,QTI. 'f '.J/+

LIi.ii T COhJTRQL. RM c:A!il.t W.U I. T TIIMl"'oR.._ll '{.,,,_ lij!CI.AR AIAltM 'l"'-1.'11*

NOTE BEE EBENCES:

1111'-I lll*IIUC 111'-I lll*IIIZIC

...i 111-111311

  • -1 111-tlQI IP*I U!l-llJIH VALVE POSITIONS ARE NOT GOVERNED BY THE UFSAR FIGURES BUT RATHER BY STATION PROCEDURES (EXCEPT VALVES IMTH LOCKED OR SEALED, AND FAILURE POSITIONS AS INDICATED) 7,4 REVISED PER UCR 2100, REV,0 DATE NO.

DESCRIPTION REVISIONS APPD.

REFER TO CRAVING MICROFILM OR MASTER INDEX FDR APPROVAL DATES AND SIGNATURES. (CADD-VECTORJ

.THIS CRAVING IS THE PROPERTY OF THE AMERICAN ELECTRIC POWER SERVICI: CORP. AN> IS LOANED UPON CONDITION THAT IT IS NOT TO BE REPRODUCED 1

2 3

5 6

7 OR COPIED, IN WHOLE OR IN PART, OR USED FOR F~-

8 NISHINO INFORMATION TO ANY PERSON WITHOUT THE IIIRITTEN CONSENT OF THE AEP SERVICE CORP,,OR FOR AN'I' P\\APOSE DETRIMENTAL TO THEIR INTEREST, A"-0 IS TO BE RETURNED UPON REQUIST" INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT BRIDGMAN MICHIGAN FIRE PROTECTION WATER UNITS 1 ~ 2 DWG. NO. FSAR FIG. 9. 8-1 ARCH ELEC DA.TEI*

DESIGN ENOINEERING DIVIIICINI

,.,...ulERK'AJII iiiMS,1CJJ1,c MECH STR AEP SERVICE CORP.

1 RIVERSIDE PLAZA COLUMBUS, OH 43215 0

9

fsar-fig-9-8-2.dgn 08/02/2013 10:11:39 AM UFSAR Revision 30.0 1

2

+

3 5

6 7

8 9

+

A z-8'6 'Dl::I 1::1\\1S::I 'ON '!>Ma B

TO UNIT NO. 2 GEN PURGING TO UNIT NO. I GEN PURGING\\\\

C D

E F

l1l VAPORIZERS~ rC::h \\

REACTOR CONTAINMENT UNIT N2 I TELEPHONE EQUIPMENT ROOM-~

ALE Slf1fU&E]

RECORD STORAGE VAULT

---~

\\

I

..r CO2 TANK~ ------

~

  • M S

7 Ya TOI-IS

..___~- ~

r,..

I S

~ I

'f I

~---*....

s

"'f

  • I LIQUID FILL LINE-**----=-==-=

VAPOR EQUALIZING LINE-~'

KEY PLAN"C" AR~ANGEMENT OF PIPING AT COi STORAc,c TP,;~K VAPORIZERS~ PIPING IN OFFICE BUILDING.

DIESEL OIL PUMP VALVE STATION ROOM s

.f.

s k

REFRIG, COMPT.

\\

ENGINEERED SAFETY TRANS. ROOM SYSTEM MOTOR CONTROL CENTER

'r- *S,-__ ----

1-------=+=--__J s

K SWITCHGEAR ROOM CABLE ~~~LT~***f**~~*~---

... s...

OUTSIDE BUILDING WALL~

SWITCHGEAR ROOMS s h CD DIE.SE.L GENERATOR ROOM

-~--------_J AB DIESEL GENERATOR ROOM

,------ SA.FETY VA.LVE. Dl~CHARGE L / -LIQUID FILL LINE VA.POR E.QU.C,.LIZING LINE CONTROL ROD DRIVE EQUIPMENT ROOM PLANT BATTERY AND TRANS-

- FORMER ROOM I 5 HALOM 1301 I

CONTROL ROOM

__ CABLE VAULT,


c:: :

s AUX CABLE

A, SAFETY VALVE_/

0 H

.J I(

I+-~ AUXILIARY BUILDING REACTOR CONTAINMENT UNIT N~ 2 I

~

T I

1/

I 5

  • ---- - +---- - -----j'--'F--......_- - _.._ ___ - ----.. - --- - --+- - -+-1-==_c'ttlP-* ~-

L TURBINE OIL TANK ROOM/

LUBE OIL R007 M

N


~----- CO2 SUPPLY UNIT Ne I

-,,.-UNIT N2 2 SEE THIS I

DWG., G/9.

s s

I I

I I

II

\\

TURBINE OIL TANK ROOM s

~ __.__ ____ _._ ~---~

KEY PLANs" TURBINE ROOM CO2 PIPING M

5 0

LEGEND MASTER VALV SELECTOR VA ro r---...,_ __ TO ELECT. PE.NE.TRA.TION ARE.A..

V 5 ',-1 s k I

V

,I

  • Sr
  • p, h

~

5 I

~

ENGINEERED SAFETY SYSTEM MOTOR CONTROL CENTER TRANS. ROOM q

1 tC02 HOSE REEL (TYPICAL}

'~

ABANDONED IN PLACE

,,....----ABANDONED IN 1

1

~

PLACE. REPLACED

~/

BY HALON 1301

~

s k s

f-',

CONTROL ROOM SWITCHGEAR ROOM CAB~y _YAU.LT 5

CONTROL ROD DRIVE E.GUIPMENT ROOM.

HE~DE.R TO CO2 HOSE..

RE;ELS

  • GABLE VAULT

---~*HALON

... K.. ~- -~--: :~

~ 1301

, ~

M K AUX c,\\BU:

VAULT

(~;,/\\

    • ~

r RE F RIGE.RA.TION COMP.t>.RTMENT I

M\\

/

,, CO2, STORA.GE TA.N K

!7 Tr.,N tTO UNITS NQI ~

LUBE OIL ROOMS AND TURBINE OIL TANK s

I-',

\\\\

II ROOMS. '.:,EE. hC 'I C 1.. t,N B. M/1 PLANT 8ATTER'f

/\\ND TRANS-

>---F0RMER ROOM K E y F' '- A N,, A'1 AUXILIARY BUILDING CO2,. PIPING I

'f

'f s

s, f--',

s C[) OIE.SEL AE DIESEL GEN ERATO!<

GENERATOR ROOM ROOM DIESEL OIL PUMP~ VALVE STATION ROOM 7

SWITCHGEAR ROOMS

REFERENCES:

OP-I W-5l53G OP-l 12>*5l53H 0P-1 {2)-5153D NOTE:

VALVE POSITIONS ARE NOT GOVERNED BY THE UFSAR FIGURES BUT RATHER BY STATION PROCEDURES (EXCEPT VALVES 111TH LOCKED OR SEALED., AND FAILURE POSITIONS AS INDICATEul.

0 REVISED PER UCR* 18IO DATE NO.

DESCRIPTION REVISIONS FILENAME:

fsar-fig-9-8-2 25.0.dgn

{raster file): fsar-fig-9-8-2=25.0.tif

THIS DRAWING IS THIE PROPERTY OF' THIE AMERICAN ELECTRIC POWER SERVICE CORP *.uc, IS LDAtED lFON CON>ITION THAT IT IS NOT TO 1!!1E REPRODUCED OR COPIED. Ill IIHDLE OR IN PAIIT. DR USED FOR F'uA-NISHINO INF'CIAMATION 10 MY PERSON vITtOJT THIE WRITTEN CONSENT OF THIE AEP SERVICE CORP.,CIR FOR ANY PURPOSE DETRIMEN1AI. TO THEIR INTEREST, Ml> IS TO BE RET'-"'CD I.PON REQUEST" INDIANA MICHIGAN POWER COMPANY DONALD C. COOK BRIDGMAN NUCLEAR PLANT FIRE PROTECTION co 2 UNITS NO. I g, 2 MICHIGAN DWG. NO. fSAR FIG. 9.8-2 ARCH ELEC IMIII *

.......... Dh'III*

NECH AEP SERVICE CORP.

1 RNERSJDE PLAZA COLUMBUS, OH 43215 IGS069 A

B C

D E

CM I 3

4 5

6 7

0 H

12 16

.J TENTHS 10 I(

20 30 L

INCHES M

2 3

N 0

1 2

3 5

6 7

8 9

COMPRESSED AIR SYSTEM UNITS NO. 1 & 2 FSAR FIG. 9.8 - 3 NOTE:

VALVE POSITIONS ARE NOT GOVERNED BY THE UFSAR FIGURES BUT RATHER BY STATION PROCEDURES (EXCEPT VALVES WITH LOCKED OR SEALED, AND FAILURE POSITIONS AS INDICATED).

BACKUP PLANT AIR COMPRESSOR 17 REVISED PER UCR-767.

17 FSAR FIG. 9.8 - 3 UFSAR Revision 30.0 2

3 4

5 6

8

'.l IGS0694 A

B C

D E

F

'ON 'OMa N

!OOPS! HEADER DETAIL A ITYP. 4 PLCSl G

AUXILIAAl BUILDING I

I I

FOP. I-IOSE C.ONN'5 lN ;ucL HAMDLINC.

l<P.EI< ~ EL.~1o'-o' H

.J K

F.C.

F~OM 01>.Y CONTROL AIR 11,ltEIVER. ~.-E Tl41':> OWG. J/1

oR \\.10
.1, toNII'!,,.Iii EL.i.,;*.o*

L M

2"TO 1-101' MACHINE $I-IOP, ~~~!!;;,_;;;;;;;;;;;;;;;;;;;;J11\\-,-'--~--+Jl'-----+---IP-IP-l~.,_ *._..., _______.,..._ ___ _. *.., _____ ~"I

~ r.;O'-o".

rnsn ROOM,/ OECC1_.~~-.. -***- -*-.. ------lf'---+-..1 ROOM,~-.. - -

TO OIES&EL C.ENERATOR ROOM:, ;eoR 1405! C0>!7 TO \\.loi;E CONN ':> IN 5ERI/IC.! e1.oo., MAC\\-1\\W!

SI-IOP, RESULTS SHOP t AUX. Ml.CHINE SI-IOP--+----..

~~\\t~~t~A~~~~~*-...,~~t.....-

TO ~OSE CONN'S. 11'/

TURBINE LAt,GINC, 3" MAKE-UP WATER""\\

SYSTEM MIXEDB!:D \\

  • DEMINERALIZERS,~

CATION EXCHANGERS.

TO CM"-HI\\CA.I..

ClU!t,,.~\\~1AWI'-.

l'OR I-IOSI, cowM'!,.I. T l,\\A\\1' 5Tll,M E>KLOSUQ.i ~EE. DI/IG.

FOR HOSE CO>llf5.

AT EL 587'*0' FOP, 1-\\05-. C:OHN'5 Ai !\\..51?>'*0' 1

.,...-FROM "N" DRY CONTROL AIR RECIEVER TO GO"TA1NMENT

.SEE TMIS DWG,. K/4 CONTROL AIR TO &ERVIC.ES DETAIL B TO DIESEL GENl:fV,iOP.

ROOM~ fOF\\ ~O~la,o.. N'S.

_ _ _______ _. __ _rt TUR~IWE G£Nf.RATOR~

\\

\\_ TO GENERATOR FOR PURGE

\\_

TO HOSE CONN:S. IN TURBINE LAGGIN(l N

DETAIL B ITYP. 2 PLCSl 0--~'---\\o --------~~-~n-------_.-1/4--------r-------_ -----_:----rr--------------,-0 1-0SECONN.F(J(

/

UNLOADING ACID _/

510~/-GiE Tl,.tJl( OR H05E COHN.

(i11'\\CAL)

PUMP AND UNIT N! 1 UNIT lol2'2 A

B C

D E

rM 1 2

J 4

5 6

G 3,,.,..,,...,, 4

>-I

.I 0

50 PSI HEADER 10 PSI HEADER 61 PSI HEADER

REFERENCES:

OP-I 12>-5120A THROUGH OP-I t2l-5120W 0P-1 12l-5120X 2

5 6

l--+-f--------+---17 R!VISIONS FILEHAMl: har-lig-9-8-3.163 (rashr fil*J : hcr-lig-9-8-3 163.cit "THIil; 111<... lllNG IS THE PROPCIITY OF ne AMERICAN ELECRIC POWE:lt SERVla COI.P. A.N~ 15 LO.t.lED U'CN OONOITTON It.AT 1T IS NOT TO 8E "E*"CIOUC-U OR COPIED, IN WHOLE Oil IN P,.IH, OIi US[0 ~OIi "UR-NlS!tlNj, lM>Ql'IHUl ON TO """< "liR!WN IIITHOUT Tl*£ IIRITTEN CONSi:NT OIC" Tl-Iii 4EP SERVICE CORP.,OR FOR " '" P~?OSE CETIUHEHTAL TO TI-EIR HITERE9l,

INDIANA MICHIGAN POWER COMPANY DONALD C. COOK DWG. NO.

NUCLEAR PLANT AEP SERVICE CO/IP.

1 RIVERSIDE PLAZA COLUMBUS, OH 43215 8

'.l

UFSAR Revision 30.0 1

2

+

3 4

5 6

7 6

A p-9*5*91:1 l:l\\fS:1- 'ON '!>MO CROSS-TIE TO UNIT N0.2 SEE FIC. 9. 8-5 I

  • 't '

I TUR\\31NE. OIL COOLER$

FROM MT/MFPT EHC CONTROL FLUID COOLERS B

  • > **>>i

f.C,,

9 Dl5CHARGE. TUNNEL

+

IGS0694 A

B

... \\fsar-fig-9.8-4_27.dgn 8/16/2017 8:49:45 AM WFX t I

  • C 11-.lTl,,KE, TtJNNa.L C

D E

F G

H J

K L

M r

AFTE.R. COOLE.R LN(,, W.e.TER FR0\\.1 C0NDUC.TlVITY ROOM.

7 I

'-10 MT/MFPT EHC CONTROL FLUID fi V

0 r

D E

VllATER JI\\CKE.T VE.NT-I CONTROL A.IR COMPR5.S$OFI, 0

. --o ----

2. ND !:> T Nc.E JNfERCOOLER 7 0

OIL C.001..ER-0

.,,~.._ __...

) 15T S1AG.I:.

I~ ~ INTER.COOLER-'

PLt--NT -'lR C.OMPRE~50R

- A.FTER COOLE.R I

LcR~SS-TIE UNIT N0.2 SEE FIG.3.8-5 FROM ICE MACHINE FROM STEAH'GENERATOR I

I

' t CM 1 2

BLOwOOWN HEAT EXCH~NGER..-..-......_.

£.ED PU~P TURBINE Lue..E OIL COOLER$

i::c' * ~. r,._

  • I. ~
=

C:001..JNC,. 'f,IA TE.R TD J CONDUCTIVJTY A.COM 3

4 5

6 7

G

  • f FRffi CONTAINMENT VENTILATlON UNITS

/

SEE FIG.1.8-6 _ __.

F 316 INCH 4 H

I,

.....1*--a.*

I I

""l WFS

- CROSS-TIE TO UNIT NO. 2 SEE F1G. <J. 8-5

(?.> WOl--l -l;.55E.NT!AL SEP.VICE. ~!>-.TE.Fl

PUMPe, 12 16 J

(10) REFR.IG.ERATION UNIT CONDENSER'S TO ICE MACHINE 1 TO DEMINERALIZED WATER

/

SYS. TE.M RETENTIOJ\\l TA.l,JK. _/'A'-t8:3-'

TO SPARE HEADERS TO STEAM GENERATOR BLOWDOWN FLASH TANKS AND HEAT EXCHANGERS SEE FIG. 11. 5-1

.A TO CONTAINMENT

~.

VENTILATION UNITS.H--e--+J<,,t-

,--l,l>i,,l----4... -4 SEE FIG. 9,8-6 7

DUPLEX STRAINER ---..... 00

~ FtM

\\.

./

CONTAINMENT

~

CHILLED WATER SUBSYSTEM I >

/4'PS ~

\\........,,'

- ;: CYCLONE

( ) (

SEPARTORS-k ",

  • I.

'\\.

~..

~

TO CONTAINMENT CHILLER CONDENSERS TENTHS 10 K

20 30 L

INCHES 1

M N

I F

  • 2 3

N l

NOTE:

REFERENCES:

OP-1-5114 OP-1-5114A 0

L SYSTEM LINEUP SHOWN FOR NORHAL FULL PO~ER OPERATION.

VALVE POSITIONS ARE NOT GOVERNED BY THE UFSAR FIGURES BUT HATH ER BY STATION PROCEDURES (EXCEPT VALVES WJTH LOCKED OR SEALE.D, ANU FAILURE POSITIONS AS INDICATED}.

7 4 REVISED PER UCR-2168, REV.!

DATE NO.

DESCRIPTION APPD.

REVISIONS REFER TO DRAWING MICROFILM OR MASTER INDEX FOR APPROVAL DATES AND SIGNATURES. CCADD*RASTERl "THIS DRAWING IS THE PROPERTY OF THE AMERICAN ELECTRIC POWER SERVICE CORP. ANO IS LOANED UPON CONDITION THAT IT rs NOT TO BE REPRODUCED OR COPIED, IN WHOLE OR IN PART, OR US£D FOR FUR-NISHING INFORMATION TO ANY PERSON WITHOUT THE WRITTEN CONSENT OF THE AEP SERVICE CORP., OR FOR ANY PURPOSE DETRIMENT AL TO THEIR INTEREST, AND IS TO BE RETURNED UPON REQUEST" INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT BRIDGMAN MICHIGAN NON-ESSENTIAL SERVICE WATER UNIT NO. 1 DWG. NO. FSAR FIG. 9.8-4 ARCH ELEC MECH STR SCALE)*

DESIGN ENGINEERING OIVIS10N1 REFER TO ORIGINAL ISSUE MICROFILM FOR SIGNATURES AEP SERVICE CORP.

I RIVERS/OE PLAZA COLUMBUS, OH 43215 0

1 2

3 4

5 6

7 6

9

UFSAR Revision 30.0 A

l 2

+

3 4

5 6

7 8

9

+

TGS0694 A

B

~

~

-~

/

L Aftercooler

~

,.. '.4 r

r

)

~

'}...

TO AUX FEEDWATER t-~--1':>=<A.!-.......

PUMP BEARINGS

~

  • ~

,. 0

~IA

~

C i,

D 0

r-2ND '.:>TAGE.

\\NTERC..OOLE.R E

1 0IL COOLE-R.


r-~~

L'1sT STAGE INTE,RC0OLE.R Q*@ -~:-:;~

PLANT AIR l.OMPRE."~:,"':>OR FROM STEAM (;EM'::P.AT<,P, BlOWDOW"I HEAT EYC.HANr_.EF\\--.,

FROM CONTAINHE~J_

_,,/

  • VENTILATION UN~

SEE FIG. 9. 8-6 CROSS-TIE TO UNIT NO. 1 SEE FIG. 9.8-4 TO STEAM GENERATOR SLOWDOWN FLASH TANKS

~ HEAT EXCHANGERS SEE FIG 11. 5-1

, r

, 7 TO CONTAINMENT VENTILATION UNITS SEE FIG 9.8-6

'. ; C:."-,;;i::::,CYCLONE

() (

SEPARATORS ~;

,]7

-~

'i' 0 0 i..~,.------ DUPLEX STRAINER W~;,

TO CONTAINMENT j y-'

CHILLER CONDENSERS B

C D

CROSS-TIE TO.J, UNIT N0.1 SEE FIG.9.0-4 E

F 7

I

  • lY',.

"\\.;' -;t Q-0 F. C.

._-D~-<7-,._

TO MT /MFPT

~

  • EHC CONTROL FLUID COOLERS L:.J CM l 3

4 5

6 7

G A

FO,

  • -~ --

~ -

G H

~

Aftercooler j Water Jacket Vent I

0 J,.

(I /'

I

_J CONTROL AIR COMPRESSOR J

See Note2 I

I I

....... ~

I I

K L

M N

0 TURBIN!= OIL COOLERS I

I I I '

  • I I I

I I

I I

_L I

J,.

  • j C

I I.

I I I

I I

l I

r J

~,..

I I

I NOTE A:

1. SYSTEM LINEUP SHOWN FOR NORMAL FULL POWER OPERATION. VALVE POSITIONS ARE NOT GOVEHNED BY THE UFSAR FIGURES BUT RATHER BY STATION PROCEDURES (EXCEPT VAVLES WITH LOCKED OR SEALED, AND FAILURE POSITIONS AS INDICATED).
2. Unit 2 only.

*~-)f(J-l"i:'&

'I.)lllf.)K"i,,.e-*llllj"......

-x-

f. C-,

7:-

,t CROSS-TIE TO UNIT NO. 1 SEE FIG. 9.8-4

\\

...~-sl-~rFROM MT/MFPT

= -. EHC CONTROL

' 'r

/'NF~,

. r

' J FLUID COOLERS

\\

{4) FEED PUMP TURBINE LUBE OIL COOLERS

~

COOLING WATER TO CONDUCTIVITY ROOM INT>'\\KE TUNNEL

,I X

L.:.J COOLING WATER FROM CONDUCTIVITY ROOM (z) ScAL OIL*

c;;.oOL!:.R5

\\,.

c~I

~

(i).,,

' -~

J

~

J I

I~

~


~----------..... --.... i---~/

~---~

\\

Di5CHARC.E'. TUNNEL

\\6 INCH 4 H

12 16 J

TENTHS 10 K

20 30 L

INCHES 1

M 2

3 N

REFERENCES; OP-2-~II*

OP-2*5.JJU 7 41 REVISED PER UCR-2168, REV. 1 DATE NO.

DESCRIPTION REVISIONS APPD.

REFER TO DRAWING MICROFILM DR MASTER INDEX FDR APPROVAL DATES AND SIGNATURES. <CADD-RASTERJ "THIS DRAWING IS THE PROPERTY OF THE AMERICAN ELECTRIC POWER SERVICE CORP, AND IS LOANED UPON CONDITION THAT IT IS NOT TO BE REPRODUCED OR COPIED, IN WHOLE OR IN PART, OR USED FOR FUR-NISHING INFORMATION TO ANY PERSON WITHOUT THE WRITTEN CONSENT OF THE AEP SERVICE: CORP., OR FOR ANY PURPOSE DETRIMENTAL TO THEIR INTEREST, AND rs TO BE RETURNED UPON REQUEST

INDIANA MICHIGAN POWER COMPANY DONALD C. COOK BRIDGMAN NUCLEAR PLANT NON ESSENTIAL SERVICE WATER UNIT N0.2 MICHIGAN DWG. NO. FSAR FIG. 9.8-5 ARCH ELEC DATE;*

DESIGN ENGINEERING DIVISIOMi MECH STR DR**

AEP SERVICE CORP, 1 RIVERS/OE PLAZA COLUMBUS, OH 43215 0

1 2

3 4

5 6

7 8

9 L~-~--cc-,---~c=-=-=~;-;--;::-;------------------------------------------------------------------------------------------------------------------ ------------~----------~----

.. 11sar-11g-9.s-5_27_dgn 8/16/2017 9:2131 AM

fsar-fig-9.8-6_23.dgn 08/28/2010 12:59:34 PM UFSAR Revision 30.0 A

9-9*5 *01::1 1

2

+

3 4

5 6

7 8

9

+

IGS06!M A

B C

D E

F G

H J

I(

l:IVS::I 'ON "OMO OUTSIDE REACTOR CONTAINMENT INS I OE REACTOR CONTAINMENT I

I

~

(4) VENTIL.ATION UNITS

.9.

UPPER CONTAINMENT

~

Unll2 Only F.O.

~.c.

F. c..

I t.OWER C.ONTAll'JMEPIIT I

VENTILATION (.)Nil RC PUMP MOTOR I

AIR COOLER UNIT Q

/Wn\\

\\....J

~*A

'"I,

~ i 9.

.9..

.... T..... -...

F.C.

F.C.

,G;:-;:,..

' ~

LOWER CONTAINMENT VENTILATION UNIT

, I I

I VO~

LOWER CONTAINMENT VENTILATION UNIT I

R.C. PU~ MOTOR

  • D+C..*--**. AIR COOLER UNIT
  • ~-:::+::)-..

--- UPPER CONTAINMENT VENTILATION UNIT

-... -------~

~

UPPER CONTAINMENT

  • VENTILATION UNIT

.9.

_9 F C.

F.C.

I

_ 9_

_'r _

-- I F C.

!':C.

L'WTI WTI r '(

'C___J I

_ 1'

_'(_

I INSTRUMENT ROOM i ~ I l

/\\

VENTILATION UND,.(WFA\\ ~FA--1

/23\\

-. ~.:

--- I~ l'Q

""~~-~'--=~ f A.

~

Uml2 Only I,

I'll 1- -

~ J I~

~~

~

-.--~,-"---"--"-

c*t:*::i-*-1----41**1-11-t------.. -~O--ll!~---~*-..;:~-------------..,;;------------------------,

f Urnt20aly

,/.......

[

i

,..*--------"--1:BJ'r--c.'rt!IIJ.*---F:-.C-1.r~f~;I--* C_. -:1_*~)_..,.'_..._:g) 'j>------.

  • 1 r.o.

F.c.

F' c..

.. _.J

~--:o.

4~!fl Urnt20aly 0

0 A

~ *-. i r

"'--~

7

~

INSTRUMENT ROOM VENTILATION UNIT UPPER CONTAINMENT VENTILATION UNIT R.C. PUMP MOTOR AIR COOLER UNIT UPPER CONTAINMENT VENTILATION UNIT LOWER CONTAINMENT VENTILATION UNIT rfA SUPPLY HEADER. SEE FIG.9.8-4 OR FIG.9.8-5 B

'Wfil J

I

. I -

....... (WFx\\

-0 R C PUMP MOTOR

.. C;K._1-.... AIR COOLER UNIT (ITT'\\

"'\\ol"Di',:::,-_,..-.._UPPER CONTAINMENT~

VENTILATION UNIT (.....__,,. '

. !~

'.J..

LOWER CO;.A~MENT7 VENTILATION UNIT

~ -

....,...a.,"'

\\

UPPER CONTAINMENT VENTILATION UNIT I'-'

I I *s

'i'.

F.C.

.. 'i'-

F. c..

I I

I I

I

~) VENTILATION UNITS -

J

,I

!.OWER CO/IITAINMEt,/T \\

  • 7 ' *

'!' 1 *

~ -

~.,,,.,.,,7'*1,,,

', ~',I, '. '

,,.,,,,.,,,~,......

{Z.l VENTILATION UNITl/S INSTRUMENTATION ROOM

' ~

~

' -~

I

~

Urnl20a~

i-i---------~--,.~---~----'?.~--~--------------------.....

F.0.---... " IJ F.C.

    • c.

7 C

RC PUMP MOTOR

..i[>KJ....iti-AIR COOLER UNIT

' ',-._ __ RETURN HEADER. SEE FIG.9.8-4 OR FIG.9.8-5 D

E CM l I

I 3

4 5

6 7

G H

12 16 J

TENTHS 10 I(

LLI J

I I

I uJ

..J II>

V)

Lil 20 I

I L

30 L

M REKTOR COOL~N1' PUMP--,

l"'OTOR II.I~ C,l)~~l=I'<?.

(?~ Pl~ MOTOR.

TOT.1..t. OF (4) PIJ~PS I I I

INCHES M

2 3

' I I

N 0

1 2

3 NOTE:

VALV E POSITIONS ARE NOT GOVERNED BY THE U FSAR FIGURES BUT RATHER BY STATI ON PROCEDURES (EXCEPT VALVES WITH LOCKED OR SEALED, AND FAILURE POSIT IONS AS INDICATED).

4 5

REFERENCES:

OP* I-C2I *5ll*A 6


t--1 7 I

I N

23 REVISED PER UCR-1~28, REV, 0, DATE "'°*

DESCRIPTIOl't REVISIONS FILENAME:

fsar-lig-9.8-6 23.dgn (raster file): hor-fig-9.8-6 23.tif APPD.

,.THIS DRAWIIIIG IS THE PROPiATY OF THli AMERICAN ELECTRIC POWER SERVICE CORP. AND IS LOANED

...aN CONDITION lHAT 11 [S NOT TO BE REPRODUCED OR CQPIID, IN VHOLI QR IN PMtT, OR USED FOR F'-'I*

NI9-IING UECIRMA TION TO ANY PERSON WIJHOUT Tl£ WRITTEN CONSENT OF' Tl£ AEP SERVICE CORP., OR FOR ANY PLRPOSE DETRIIENrAL 10 Tl£IA INTEREST1 AM) IS TO BE RETIMED uPON RECIUESY-INDIANA MICHIGAN POWER COMPANY DONALD C. COOK BRIDGMAN NUCLEAR PLANT NON-ESSENTIAL SERVICE WATER UNITS NO. 1 ~ 2 MICHIGAN DWG. NO. fSAR FIG. 9.8-6 MICH ELEC DATIi*

MECH AEP SERVICE CORP.

1 RIVERSIDE PLAZA COLUMBUS, OH 43215 0

8 9

fsar-fig-9.8-7_21-2.dgn 3/7/2008 10:52:05 AM UFSAR Revision 30.0

+

3 5

6 7

8 9

+

A I

,-s*s*m::1-H\\fS::1- *oN '!)M(] I TO UNIT NO. 1 CONTROL ROOM AIR CONDITIONING CONDENSER SEE SK "G-2" I

+-

I -

I

(

... ~--.. --_-

TO"lbAFP

  • ENCLOSURE COOLER

\\_

~

TOEMDAFP ENCLOSURE COOLER I

C I

D I

(2) CONTAINMENT SPRAY HEAT EXCHANGERS t

..---e-1.... --------.

TO UNIT NO. 1 CONTROL ROOM AIR CONDITIONING CONDENSER SEE/

t FROM UNIT NO. 1 CONTROL ROOM AIR CONDITIONING CONDENSER SEE SK "G-2" TO TURBINE DRIVEN AUX. FEED PUMP SEE FIG, 10.5-1 TO MOTOR DRIVEN ALIX.

FEED PUMP SEE FIG. 10.5-1 I

~

/\\

I IGS069' iJ

'N

  • --~1--1-""-r-

-- ESW TO AFP ENCL.

COOLER RETURN

.II "I

~ " I

..... } TO &FROM HEAT l i

'l EXCHANGERS FOR OTHER~

EMERG. GEN. DIESEL I W ii,

~~

C -.. ;,.~-

\\J ESW TO AFP ENCL

/

COOLER RETURN

..... "-..._*--->Kl~-..

A I

B I

,G,.i\\

.\\../

I JACKEi WAlt:t<

COOLER I LUBE OIL COOLER I

HEAT EXCHANGERS FOR EMERGENCY GEN.

DIESEL ENGINE

'TO DISCHARGE TUNNEL I

C I

D

'~.

~

I E

I F

I

/FROM AIR HANDLING UNIT G

I TO AIR HANDLING UNIT ~

,II, H

FI

~2 n

,(:;.,l('. _______.-.ci.

(4) CONTROL ROOM AIR CONDITIONING CONDENSERS

'-RETURN SEE THIS DWG CIS, U5 SUPPLY SEE THIS OWG D!2, A/3, J/2, N/3 SKETCH "G-2" TYPICAL ARRANGEMENT OF PIPING AT CON1ROL ROOM AIR CONDITIONING CONDENSERS p

I I

t t

(4) COMPONENT COOLING HEAT EXCHANGERS I

-.)

TOW-MDAFP ENCLOSURE COOLER E

e---t~._ TO TDAFP ENCLOSURE

.. COOLER NF"A WP:.

fl TO MOTOR DRIVEN AUX, FEED PUMP SEE FIG. 10.5-1 UNIT N0.1 UNIT NO. 2 w

- ~

I

)

WP FROM OTHER ESSENTIAL SERVICE WATER PUMPS P.

~

I I

(4) DUPLEX STRAINERS (4) ESSENTIAL SERVICE WATER PUMPS I CM I

~

3 F'4 5

6 7 I G

flp I

PS ii H

I hs J

I I(

TO UNIT NO. 2 CONTROL

\\

ROOM AIR CONDITIONING

\\

CONDENSER SEE SK "G-2"

\\

\\

TO & FROM COMPONENT COOLING SYSTEM SEE FIG. 9.5-1 TO & FROM CONTAINMENT SPRAY SYSTEM SEE FIG. 6.3--1 FROM UNIT NO. 2 CONTROL ROOM AIR CONDITIONING CONDENSER SEE SK "G-2" I

w L

I M

(2) CONTAINMENT SPRAY HEAT EXCHANGERS

---, I..------~

~

I

.--,,---------. ft

'NFI t:a I

ljjil1'\\

~

TO MOTOR DRIVEN AUX, TO *w* MDAFP FEED PUMP SEE FIG. 10.5-1 ENCLOSURE.,_.. __

  • I I

N TO UNITN0.2 CONTROL ROOM AIR CONDITIONING CONDENSER SEESK"G-1/

f I-+

I I

D NOTE:

SYSTEM LINEUP SHOWN FOR NORMAL FULL POWER OPERATION. VALVE POSITIONS ARE NOT GOVERNED BY THE UFSAR FIGURES BUT RATHER BY STA1ION PROCEDURES (EXCEPT VALVES WITH LOCKED OR SEALED, ANO FAILURE POSITIONS AS INDICATED).

.., 1..,.

~

k ~

COOLER

~

/

..._ TO "E" MDAFP

_,r_,.-...____

,111..

1111.

  • INDICATION ONLY.

.-----------~,;~ ENCLOSURE COOLER

.....-1111--**-... ---.1-'"f.. -.. r,-..

J L

~ -

TO TDAFP ENCLOSURE rn TURBrNE DRIVEN Alx.

I

  • ftC"I -

COOLER -

,=

FEED PUMP SEE FIG. 10.5-1

-~ \\

I

/i, ~I /\\

J

'".. ~'~

itfit,l\\

i.

.~

l

'J

t.

l J

TO AND FROM HEAT EXCHANGERS FOR OTHER EMERG. GEN. DIESEL ENGINE

(

FAIL TO AIR INTAKE MANIFOLDS (2] AIR INTAKE MANIFOLDS

)

I JACKETWATER I COOLER I

I LUBE OIL COOLER I HEAT EXCHANGERS FOR EMERGENCY GEN.

DIESEL ENGINE TO DISCHARGE TUNNEL I

L I

ESW TO AFP ENCL COOLER RETURN -..

I I

ESW TO AFP ENCL COOLER RETURN ~..

N

REFERENCES:

lP-J ~2>-51ll OP-1 *~>--~lJl.l.

11.l REVISED PER UCR-18'41,REV.0, DATE ND.

DESCRIPTION REVISIONS APPD

-THIS DltAIIINO 11 THI! ~ltTY 01' THI! AMERICAN ELECTRIC POWER SERVICE CORP. AND IS LCIAIED uP011 CONDITION THAT II IS NOT TO BE AEPRCIDUCED OR COPIED. IN WHDLE OR IN PART, QR USED Fmt Fl.R-NIIHINO IWCIRMATION TO ANY PERSON IIITH0UT,...

WRITTEN COldEIIT OF' THIE AEP SERVICE CORP.

  • DR FDR ANY PI.RPOSE DETRIMENIAL TO IHEIR INIERl:ST, AMJ IS TO BE AETI.RfED I.PON REIIUEST" INDIANA MICHIGAN POWER COMPANY DONALD C. COOK BRIDGMAN NUCLEAR PLANT ESSENTIAL SERVICE WATER

~ITS NO. 1 g, 2 MICHIGAN DWG. NO. fSAR FIG. 9.8-7 AllCH I ELEC I NECH I I SIR I Ill.Ill*

CHI*

111S1C111 IGIClll!N DIWI-fiij -- 1 AEP SERVICE CORP.

!!!91!'(

J'fff:,;f/:5,~

I 0

3 5

6 7

8 9

...\\UCR-2088\\FSAR-FIG-9-9-1.27 12/10/2015 10:04:14 AM UFSAR Revision 30.0 A

L-6'6 Dl:I l:IS'lf:I 'ON '!>MC 1

2

+

3 5

6 7

8 g

+

lGS069 A

B B

o I UNIT N VENT A*

C ITEM i,jll I

'2 3

4 5

Gt 7

e 9

10 II I '2 1 '!

14 I 5

' (o 17 I!

"' f'9""

20 C

COORD, EC.

C:i,4,

!j 5 DS e. l<.5 05$1<5 HI "ils ISi JS FS $GS C7 I; J7 C? tJ?

EG.

FG. $ QiG, FCil $Gt:.

ea:.

07 I-IG,,Jrt,I<&

ea?~CE>

C7 A8 ~ l!.8 A. -

N! or CONNI.

I

2.

I

a.

Z, 5

2.

2 I

2.
2.

I' I

4

2.

I 6

D E

LOCATION (AR!.lt, 011. !NCLOIURE)

Pl.CONTAMINATION 1!.RI..,_

L!T DOWN Ht~'T tlCCHANIIR

~~J'.. ~~1.,.C?_EJ~,~!l~A l"'I I NA I ION

"-'N !QU\\P'M!NT ROOM CATION 81.D D!MIN.

MIK!tl 8!0 D!Mli'I.

CtlORA.TING DEMIN.~ ~PEN'l'r1Jt1 PITDEMIIII

!VAIi! ~u:c \\OM EXCHANGER t°1~~iE11!..,\\1,TIAL SIRVICI WATl!'II

~ORICACIP INJECTION Ti\\NK WAl'I' t IAI COMflll.lllOII.$

W\\.UME CON'TII.O I. TAM'-

$IA.I. WATElt ~EAT ElC~A.lilGl.lt.

CONCENTRATE f.101.PIN& TANK Plitt TIINl'lt.\\.

MONITOR TANIC.I MOT 1.A!iOR,._TOR't' I-IOOP EX HA.UST MOT 1..-.SORA. '!'ORV CAEl1 NE.T EX 1-1._UST V

~ '

DPIUM STO"Alil ¢ ORIJMMINGi,t1,*,~

D WASTE GAS DECAY TANK VENT SEE FIG, 11. 1-3

~ -

1/2. 1 1""01"1,.... N~ '11!:NT R.A01A.'T" ION.... 1"'11"1.,I NG,

&"1' Ir 'T' I. i"'I,

E

)

'\\

CM I F

G H

liE'M COO~C>. NI 01' LOCATION

  • N 11.

CONNS.

( AR!.A O" l9'CI.Oll.l"I )

2. I

&8 I

IIIINT MIIN ITOII.AII TAIO,

'2...'Z.

ce I

WAITI.. IW.l'I 11-.LMII (2 GPM) 2, !,

ce I

SAMPI.INCi ROOM IAMPl.l ~INK HOOP 24 e&

I SFIPIAV AODITlVE 'l'AHIC ZS ca.

l 5AMPI.I "OOM P.ACK 'c.'

2.G ca I,

WAITI lVA!t,,1.t0 FIL Tl,ll

'2. ?

08 I

w-.&Tt HOL.0* \\JP 'TAMIC. *

'Z 8 08 I

Pt.lFll,LI NGi WATlll rn. Tt.l 2.9 ea $1<8

2.

"l'I ¥'.tAY 30

~S$J8 2

C0NC.lNTII.ATL ~ 11-.1. WTl,IN~EC'I' ~I1..T!.R 31 E 8 ¢ \\.&

VAi.Vt Ol'l.1'ATINI GIAl.1.tll.'I'

32.

E8$L8 l

BORIC ~"D EVAPORATO" 3!

FBtL8.

2, II.EC, Pl.HIT~ATIOM 34 F&.ICB 2,

,i !It T\\UOII.I.

35 F8t1C.&

2.

'CIA.S 01.CAY TA.NII.,l,.lll'-

~ r..

J6$H6 z

RIA,CT0"- COOi.ANT FIi.Tiit.

3 7 F9 $ 1(.9

2.

l'IPl TUNNll.

3&

G961<9 2

REACTOR CCOl..lt.NT PR..,IN TA.NII. Pl.IMP

~9 J9 I

'IUMfl TA.MW. e P\\IMII 40 H9 I

AUX, 11.0G, IIIMP

. 4 I 07 I

SPl!NT FUEL. PIT F'U MP!,

4'Z Dl:P I

N~W FUEL.STOlt.Atac ROOM J

I(

ITEM

COORO, NII Nt OF CONN$,

L I.OCi\\TION (AltE.A OR ENCI.O'!IUREI I-IOLl:>-UP TA.NII.I M

44 M9 I

!10RIC,\\Cll)!\\l~P.F!!PPUMP$

45 EC-.

'l.

MOT M,l,.CHINE. $HOF' S 2 A/7 I

HOT LAl!IO~A'roRV HOOD EXHAUST, S 2i e/,

I

,-,ccESS CONTROi. ARr~ TOILlTS $1.0t'l<ER S 4-

~/7 I

PERSONNEi.

OECONTAMINATION AREA

'! 5 e/7 2

HOT LABORAiO~'!' HOOP BY F'A'Sl'!i f----+----+---+------------~

!5 la A/7 1

AiOMIC. AB'&>RF'T\\ON HOOO VENT

!S1

~/71 ~/7 2

VENT ~OM LAUNDR'!' ROOM 1----~--~----1--------------

C/8 1

C/7 3

E,I

!>/7 I

N UNIT NI'!

VE.NT

©..... -1 0

SYMBOi.i lil.ElilSTE~ WITH OPPOiED 11...t.DI!.

DAMP!R..

~EP.l. FILTER ROUGHING FILTER IIEl.'l'ING CQII.

COOL.ING CO.II.

Fi!OLL TYF'E PFi!E*F'LTER 1

2 3

©~...... -o-1 © CA.MF'&"

N0RMALLV CI.OS!C 0

3 4

5 6

7

z

~

[BJ 5 ! ~-11]111x¥~~

2

  • CAMPER NORMAi.LY OPEN BACI( O~AFT DAMPER MOTOFit ()!'~RATt.O c,.,.111,, R 5

© ©

~ 1------

il!e~PB!~l~oiJg~i Ngi G~V~t~~D

,-~t-,::)i-+++--4,,__. __ ~,-------.. ------------"'"'!r-l ~ (Z) ~~~T~~f~,J~Mt~,~~ ¥!r~fr~;~~~~I~~~~8A~~~mo~~D G

316 INCH 4 H

12 16 J

TENTHS 10 I(

20 30 L

z

i tll'IIIA.T <l\\001Tlvt TA.~W.

ROOI'\\ "IL.ill/\\ ~.!1'!'

INCHES I

M 2

3 N

REFERENCES:

6

._.............. _______ L--1 7 REVISED FOR 1

  • UCR-2088 REV 1 DATE NO.

DESCRIPTION REVISIONS FILENAME:

FSAR FIG 9-9.l.27

!raster file): FSAR FIG 9.9*1_27.TIF

  • THIS DRAVINCI IS TtE PROPERTY OF' THE AMERICAN ELECTRIC POWER SERVICE CORP. MID IS LOMED I.PON CONJITIDN THAT IT IS NOT TO BE REPRODUCED OR COPIED. IN ltHOL.E OR IN PART* OR USED FOR FuR*

8 NISHING INFORMATION TO ANY PERSON VITICIUT THE IIRITTEN CONSENT OF Tl£ AEP SERVICE CORP.,DR FOR ANY PURPOSE DETRIMENTAL TD THEIR INTEREST*

AND IS TO BE RET!.RNED I.PON RECk£Sr INDIANA MICHIGAN POWER COMPANY DONALD C. COOK BRIDGMAN NUCLEAR PLANT AUXILIARY BUILDING VENTILATION UNIT NO. 1 & 2 SHEET 1 OF 2 MICHIGAN DWG. NO. FSAR FIG. 9.9-1 ARCH ELEC NECH STR AEP SERVICE CORP.

1 RIVERSIDE PLAZA COLUMBUS, OH 43215 0

g

COMPONENT COOLING PUMP AREA SKETCH "D-9" COMPONENT COOLING PUMP AREA VENTILATION SYSTEM NOTE:

VALVE POSITIONS ARE NOT GOVERNED BY THE UFSAR FIGURES BUT RATHER BY STATION PROCEDURES (EXCEPT VALVES WITH LOCKED OR SEALED, AND FAILURE POSITIONS AS INDICATED).

FSAR FIG. 9.9 - 2 AUXILIARY BUILDING VENTILATION UNITS NO. 1 & 2 SHEET 2 OF 2 Revised per A) UCR-295 B) UCR-1482 17 F.C.

F.C.

17 A

B 17 OP-12-5148 F.O.

F.O.

1 OF 3 SETS F.C.

F.C.

17 B

B 17 UFSAR Revision 30.0 f-2 A

B C

z-&-n> 1::1 1,11,s::1 *oN '!)M(l OUTSIDE.A.UX. BUILDING r - - - -

-INSIDE,,_Ul(, BUILDING I

SUPPLY UN.IT rCOND.RE.TURN TO COMPONENT

/~

PPL COOLING PUMP VENT.

"'TEAM SU

'(

f>Y'o TEM.SEE SK " D* ':l"

- --7 I

I I

D I FRESH I AIR I 1NTAKE I LOUVER I

I I

I i

I SUPPLY ~:G~S;E~

E 3

(UNIT NO, 2 ONL'/)

L TO COMPONENT s

PPLV COOL.ING PUMP VENT.

TEl>.M SUrn;_,...----_

S'l'STEM.SEE SK ' D*':l" 4

5 6

8 9

A SUPPLY REGl!:JTE.R _ ___/

UN I T NO I 0"L'(

(UNl'l' NO. 2 ONLY)-'----

J 5\\.JPPLY R!:GisrER U N.lT NO 1 :)NL'(

SUPPLY REGISTE.R----

SUPPLY REGISTER,--- /-

B Sl<.E.TCH " D-5" AUXILIARY BUILDIN6 GE.NER/>.L SUPPLY VENTIL1'TION (TY PIC1'L FOR UN IT I OR 2)

(4UNOTa,TOTAL- '2 foREAC-H UNIT)

C D

E CM I F

I G

'5UPPLY

{'"'--REG,ISTER5 J

4 5

6 7

G H

TO PLANT VENT SEE FIG. 9. 9-1 ITEM 50 2 Ell.HAUST UNIT:,

(I ST1'NDBY)

OUTSIDt AUX. BVILDING INSIDE AUX, ~UIL.PING SPE.NT FUEL POOL H

II 16

..J K

i L

M E.NGINE.ERE.P SMETY FEATURES VENT 1'NP PIPE 51-lAFT

-} FROM CONTl>.INMENT SPRl>.Y HE1'T E.XCH. ENCLOSURES.

1-0---i

-} FROM RESIDUAL HEAT EXCl-l,ENCLOSURES.

-.a----

FROM S,O..FETY INuE.CTION PUMPS ENCLOSURE.'5.

/

!'ROM CENTRlrn61>.L CHl>.RGING

-.rs--.,;~ PUMP ENCLOSURES FROM RECIPROCA.TING CHARGING PUMP ENCLOSURE..

l='ROM RE.SIPUl>.L HEl>.T

  • od--oiiJ RE.MO\\IALPUMP$ ENCL05URES.

FROM CONTl'.INME.NT SPR,O..Y PUMPS ENCLOSUl<E.S.

SKETCH *1..-S' ENGi N E.ERED SASETY FEA.TURE VE.N'Tll..,O..TION SYSTEM (TYPIC1'L FOR UNIT I OR 2)

FRESH,O..IR INT-'KE ~

I LOUVER ~

[i FUEL HANDLING ARE,O..

N

'--coNDE.NSATE. RHURN(TYP)

..J TO UNIT NO. I VENT SEE FIG. 9. 9-1 FUEL HA.NOLINC. />.ll.EI>.

E. XK/0,.UST FANS t I STl>.NDBY )

TENTHS 10 K

20 30 L

t LFRESH AIR INTAKE LOUVER SKETCM "M-9" l"U EL HANDLING V E.NTIL,,_ TION SUPPLY SY!:.TEM INCHES 1

M N

0 SYMBOL';,

!,ACI( 0/2AF'I' OAMPE~

All2 OPEIZATE.D DA'-'1PE2 PAMPER (N,0,)

DAMPER (N.C.)

EXH1'UST HOOP REGISTER WITH OPPOSED BLADE DAMPER CHARCOAL FILTER HEP/>. Fl L.TER ROUGH I NG l'ILTER HEi.TING COIL COOLING COIL

@::M TYPE Pli!E*FILHR REVISIONS "THIS 0~ 1,,VI~ I S 11-tE ~ OPE.RH OF" THE AMflJCAN E~Ec:TJUC POWER SERVICE C:0ltP *.o.w IS LON.ED lJf'ON CONDITI ON Tft> T lT IS NOT TO ~ E REPf'/00\\!aiD 6

o<< C~!E.D, I N \\MOLE (!fl IH ?a.11.J, OR USED FOR f\\!R-8 N!SHilfO Il'l'ORHA.TJON TO.o.N, P.RSOO ~ITHOUT HE 1111nrrn CO.SENT OF TIE ~* SERVICE CORP., OR FOR"1trF'ORF SE OE TR lMEN TALTOTHE IRIHTEREST,

INDlANA. MICHIGAN POWER COMPANY DONALD C. COOK DIW. NO.

NUCUAR PLANT AEP SERVICE CON'.

1 RNERSIDE PLAZA COLUMBU~ OH 43216 0

UFSAR Revision 30.0 1

2

+

3 4

5 6

7 8

9

+

A L-0L '6 *01:1 llVS:l 'ON '9MO IGSOS94 A

HUMIDIFIER PACKAGE FSAR*FIG-9.10-1_27.DGN 7/28/2015 9:10:53 AM B

2 STAGE ELECTRIC BLAST COIL B

C 27.0 D

RETURIJ TO r ESSENTIAL 51:RV~~

WA. T'S It AIR CONDITIONING UNIT E

NORTH l-ro CONTROl.

ROOM VENT-r EXPANSION TANI<

CHARG t NG BOTTLE R.ETVRN TO -.......

ES$E1'1TIAL SERV!CE w-.'!'1::ll..

LIQUID CHILLER PACKAGE FROM ESSENTIAL SERVICE WATER HEADER

_ TO CONTROL ROOM I

[

l

-,.I AIR DISTRIBUT\\01'1 SYSTEM

+\\_To COMPUT~R RM.

C D

I

  • l.

I

  • I
  • I
  • I j
  • l j

l.

l

,---'--~--II,,- SIGHT GLASS PRf:SS.

R1:DUCING VAI..VE

,..--MAl<t. UP WAiER.

SOUTH E

CM I 2

3 4

5 6

7 G

H J

' I>. {::,.

~i,/i, 4 *c,.*

X X

X X

X X

-t>-:

. [>

!i't:-...

x X

'\\c~

X X

X 2 FANS CONTROL ROOM PRE.SSURIZER UNIT FROM J Ct:lNTROI..

ROOM UNIT 1 G

\\6 INCH 4 H

12 16 J

K F.A.I.

I I

I Bubble Tight Butterfly Damper I (Typ.)

F.A.I.

F.A.I.

TENTHS

.--I-RETURN AIR

~

~

FROM HVAC I EQUIPMENT RbOM I


t-- RETURN AIR I

I~

'-r-..

O! IOf Ill !!:!

O!

0: 10!

[): <(

4'. ro al wl~

..J -

l/1

~I~

µJ,~

9 iii

~,~

  • 10 K

20 FROM CONTROL ROOM.

30 L

M L

INCHES 1

M 2

3 N

SYMBOLS MANUA.L VOLUME DAMPER 0

{J N..ORMALLY OPEN DAMPER JI NORMALLY CLOSED DAMPER

~

BACK DRAFT

~

DAMPER

~

m I

~

ROUGHING OR PREFII..TER AE!.SOLUTE FILTER CHARCO.l>.I.. FILTER CHILLED WATER COIL COhl.:tROL OFF ReFRIGERANT LINE TEMPERATURE OR PRESSURE ELECTRIC BLAST COIL HEATeR NOTE:

VALVE POSITIONS ARE NOT GOVERNED BY THE UFSAR FIGURES BUT RATHER BY STATION PROCEDURES (EXCEPT VALVES WITH LOCKED OR SEALED, AND FAILURE POSITIONS AS INDICATED).

REFERENCES:

oP-1. (2>-5149 1

2 3

4 5

6


ll--+-----------11--- 7 N

27.o REVISED PER UCR-2057, REV.O DATE NO.

DESCRIPTION REVISIONS REFER TO DRAWING MICROFILM OR MASTER INDEX FOR APPROVAL OATES ANO SIGNATURES, CCAOD-RASTER)

"THIS DRAWING IS THE PROPERTY OF THE AMERICAN ELECTRIC POWER SERVICE CORP. AND IS LOANED UPON CONDITION THAT IT IS NOT TO BE REPRODUCED CR COPIED, IN WHOLE OR IN PART, OR USED FOR FUR-NISHING INFORMATION TO ANY PERSON WITHOUT THE WRITTEN CONSENT OF THE AEP SERVICE CORP., OR FOR ANY PURPOSE OETRIMENTAt... TO THEIR INTEREST, AND IS TO BE RETURNED UPON REQUEST" INDIANA MICHIGAN POWER COMPANY DONALD C. COOK BRIDGMAN NUCLEAR PLANT CONTROL ROOM VENTILATION UNIT NO.1 MICHIGAN DWG. NO. fSAR FIG. 9.10-1 ARCH ELEC DESIGN ENGINEERING OIVISIONr MECH STR AEP SERVICE CORP.

1 RIVERSIDE PLAZA COLUMBUS, OH 43215 0

8 9

...\\FSAR-FIG-9.10-2.26 2/3/2015 4:20:27 PM UFSAR Revision 30.0

+

+

A I

z-0L*s*91~ l:l'IS~ *oN '!>Ma l

2 HUMIDIFIEI 3

5 6

7 8

9 PACKAGE IGS069<4 A

I!. STAGE ELECTRIC BL~E,i C.OIL HUMID IF I El PACKAGE I

B I

C I

D

..J

~

=~

I'\\

c8

~ ~.: ~

)

~

..l L,11

~~~~

.. I-

r <

u~

{Ml1~11"

--~

\\..

IUTl/11.IJ '\\'O f

,I

'* jiSIMTIAL

'.*~

Pl\\111:1

-,~ WA.T'lil I':);

  • ¢-

e LIQUID CHILLER

,~

~

PACKAGE

  • -----~--*-*-*-*-*:;.f"*-.* ---------

1,---- ~--

~~~v --1

  • I 1 - -.1.... _ - - -

l°'~/ vf-+ :00-Loo-rC I ~

a I I I

  • EVAPORATOR l i f ICllll'RESSOR 7 COt<<lENSER r o

'I I

I J L+ t"--/v"'\\ :--* -

L J

X II c214~~R t, __ ----, r I J-I f

ICOll'REssoR 1 COt<<lENSER r 1

-+-I I-+ l"V',/V"',

---* 9 L...Q_ J 1* f rATER REGULATING :

COMPRESSOR

  • VALVES i;> I CIRCUIT 2 L---*

I FROM ESSENTIAL SERVICE WATER 1AOER

\\

}

Ess!inAL SERVICE WA1JfRJ 1~

\\AIR CONDITIONING. U>-JIT C

\\._

H LIQUID CHILLER PACKAGE r*----------------------- ---------

.--~- ~-

_~~ --1 1 r--.1....---- '"'~._,,....;+- '°°"" 1.oo-1 I

~ EVAPORATOR l I.!.

~

I f !COMPRESSOR 7 CONDENSER r '

I J L + I I

LCOlf'RESSOR J

~

f X

I CIRCUIT I I ~

I

. f

!COMPRESSOR 1 CONDENSER r 1

! -+-I 1--+I -~-~-~-~

---* 9 L...Q_ J 1

fiATER REGULATING : :}ii,aAL I

COlf'RESSOR

¥ VALVES 9 I

  • WATER CIRCUIT 2

~

~

, ~

!£ADER SERVICE WATER HEADER

_ 1

/26.

. TO COIIITR.OL ROOM

. AIR 0ISTRIBUTION S'l"SiEM

\\_

'1b CCMPUTIFI RM, B

I C

I D

I E

I F

I

(

l.

  • H" INORTHI f.J p,-,ss.

R!DUC1NG VAi.Vi!

I l-T"O CONTROi..

R.00M ISOUTHI I

I I

I I

I I

I I

E lcM I 2

3,-4 5

6 7 I 0

I H

I J

'*[>',C l~

'o.*t>t::.

4*t>'

~

t>',<3'

~-i:>:

~

','.0.

A,().,

'2 FANS C:O~iROL ROOM l=RtSiURIZER U'-IIT I

1111 FiilOM J CONTROi.

ROOM I UNIT 21 I

0 H

'12 116 J

I I(

I I

J_

LB-fJ- ~

F.A.I.

Bubble light I BullllrtlyDamper

{fyp.)

I

___._REtURN AIR

~

~

FROM HVAC

~-- I ltu6~ENT I

L

.---t REiU"-N AIR.

FROM C:ONTROl.

R.OOM.

11

    • , I
  • I **,,

!TENTHS 110 I(

120 130 L

I M

I I

I I

I I

I 12 N

N01E:

I 0

5XMS06$

MANW4..L VCLUM!

CAMP'EA t;j N..ORMAi..LV OPl!N DAMPER

,. NORMll.1.LV c1.ose:c CAMPER

~

BA.C.I( ORAFT,

~

O~M'Pi'R.

~

RO.UC!iHlNG. OR

~

P..RUI\\..TER I Al,SOLUTE Fl l T!R CMJIIRCO..,_I. FIL T Flt

~II.I.ED WATER COIL COllll'.ROI. OFF Rl!P"RIC!!iERA.NT LINE' Tl!MP~~iURE OR PRES')UR£'

VALVE POSmONS ARE NOT GOVERNED BY THE UFSAR FIGURES BUT RATHER BY STATION PROCEDURES (EXCEPT VALVES WITH LOCKED OR SFAI El'l, AND FAIWRE POSITIONS AS INDICATED).

REFERENCES:

0P*I 121-1111 l

2 3

5 6


7 Revised per UCR-2002, N

126.C UCR-2083, UCR-2068 &

UCR-2069 DATE NO.

DESCRIPTION REVISIONS REFER 10 DRAWING MICRIJ'ILM OR MASTER ItllEX FOR APPROVAL OATES ANO SIONATIJlES. tCAOO*RASIER>

  • THIS DRAVINIJ IS THE PROPERTY OF' THE AMERICAN ELECTRIC POWER SERVICE CORP. MID IS LOMED I.PON CONJITIDN THAT IT IS NOT TO BE REPRODUCED OR COPIED, IN ltHOL.E OR IN PART* OR USED FOR FuR*

NISHINO INFORMATION TO ANY PERSON vJTtQJT THE IIRITrEN CONSENT OF THE AEP SERVICE CORP.,OR FOR ANY PURPOSE DETRINEN1AL TO THEIR INTEREST, AND II TO IE IIET!.RNED I.PON AECk£Sr INDIANA MICHIGAN POWER COMPANY DONALD C. COOK NUCLEAR PLANT BRIDGMAN MICHIGAN CONTROL ROOM VENTILATION UNIT NO. 2 DWG. NO. FSAR FIG. 9.10

  • 2 ARCH I ELEC MECH I I STR I IDAIII
  • l'l'!'!I JIMIIRICJIN li,M KKmlC -

I AEP SERVICE CORP.

1 RIVERS/OE PLAZA COLUMBUS, OH 43215 0

8 9