ML17332A041

From kanterella
Jump to navigation Jump to search
Registration of Spent Fuel Cask Use
ML17332A041
Person / Time
Site: Holtec, Vermont Yankee  File:NorthStar Vermont Yankee icon.png
Issue date: 11/16/2017
From: Chappell C
Entergy Nuclear Operations, Entergy Nuclear Vermont Yankee
To:
Document Control Desk, Division of Spent Fuel Management
References
BW 17-040
Download: ML17332A041 (2)


Text

~Entergy BW 17-040 November 16, 2017 ATTN: Document Control Desk Director, Division of Spent Fuel Management Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Washington, DC 20555-0001

\\

Entergy Nuclear Vermont Yankee, LLC Vermont Yankee 320 Governor Hunt Rd.

Vernon, VT 05354 (802) 257-7711 Coley C. Chappell Manager, Design & Program Engineering 10 CFR 72.212(b)(2)

SUBJECT:

Vermont Yankee Registration of Spent Fuel Cask Use Vermont Yankee Nuclear Power Station Docket Nos. 50-271, 72-59, and 72-1014 License No. DPR-28

Dear Sir or Madam:

Entergy Nuclear Operations, Inc. (ENO) operates the Vermont Yankee Nuclear Power Station (W) Independent Spent Fuel Storage Installation (ISFSI) in accordance with the general license provisions of 10 CFR 72.210. In accordance with 10 CFR 72.212, "Conditions of general license issued under§ 72.21 O," paragraph (b)(2), registration of the use of each cask is required no later than 30 days after using the cask to store spent fuel.

The following information is provided in accordance with 10 CFR 72.212(b)(2):

Licensee Name Licensee Address Reactor License Number Reactor Docket Number ISFSI Docket Number Contact Name and Title Cask Certificate Number Coe Amendment Number Entergy Nuclear Operations, Inc.

Entergy Nuclear Vermont Yankee, LLC 320 Governor Hunt Rd Vernon, VT 05354 DPR-28 50-271 72-59 Coley Chappell Manager, Design & Program Engineering 1014 10

BVY 17-040 / Page 2 of 2 29th Cask Cask Model Numbers Cask Identification Numbers 30th Cask Cask Model Numbers Cask Identification Numbers 31 51 Cask Cask Model Numbers Cask Identification Numbers

\\ \\

Initial Use: October 23, 2017 Overpack: HI-STORM 100S Version B Multi-Purpose Canister: MPC-68M HI-STORM Overpack: Serial Number 990 Multi-Purpose Canister: Serial Number 546 Initial Use: October 27, 2017 Overpack: HI-STORM 1 OOS Version B Multi-Purpose Canister: MPC-68M HI-STORM Overpack: Serial Number 997 Multi-Purpose Canister: Serial Number 549 Initial Use: November 02, 2017 Overpack: HI-STORM 100S Version B Multi-Purpose Canister: MPC-68M HI-STORM Overpack: Serial Number 998 Multi-Purpose Canister: Serial Number 552 This letter contains no new regulatory commitments. Should you have any questions concerning this letter, please contact me at 802-451-3374.

Sincerely, llr~Aul,(__

CCC/dme

/

f'"'

cc:

Mr. Daniel Dorman Regional Administrator, Region 1 U.S. Nuclear Regulatory Commission 2100 Renaissance Blvd, Suite 100 King of Prussia, PA 19406-2713 Mr. Jack D. Parrott, Senior Project Manager Office of Nuclear Material Safety and Safeguards U.S. Nuclear Regulatory Commission Mail Stop T-8F5 Washington, DC 20555 Ms. June Tierney, Commissioner Vermont Department of Public Service 112 State Street - Drawer 20 Montpelier, Vermont 05602-2601