Text

H G

F E

D C

B A

8 7

If>

"i fl 0 /I I-

,fl r I

ll-

I ~-:Z r

PP>f, fll-T!el', A.NP W-~\\'f. Fil-TE.I',

i;:_ iu ::,

V4-IO<.l OOO I J

0 1 :,: :UT OFF D,._MPl>P,/

V4100F01e, I::

<?<',r-,=-

.SHt.:T OFF PAM PE"-. 7 V4\\0-:>FO!Z 1,,.--.._,

6 CHILLED 1,iATER

)M-4953 (H-4i)'",-,,-,.-,

=:,Llf'PLj'

  • s~

-- -.,, - *7 If

'~:J

<:_4953-(£_-5~-

I,/1,

\\

To i'I 2.

i..J}-..1 45 r'rT' I\\ '-

5 3/4" (V)

F306 1-1 I r-:

~-

ru II

~

Lf)

I

,tJ

'£ IL

,j ro.. -"' -

1-,

u -

Lf)

I I,

t I()

ru

,n -

Lf)

~

Lf) ru..

(")

2664t,FM 4

2076CFM 2076 CfM I-587 ::'..FM

..L. WA~H~OWN 3

2 1

NOTES:

SEE DRAWING M-4953.

A

~I~

~,;;,

I 4 -

- - - -- -- -- - - ___________ 802 C.FM 1 & -

124 c.FM

---i I

I I

) M-4945 <F-5))

1{1

-I

,.1 t'.i I

I I

I I

I I

I

.L

..J...

810 GFM F;V"fOP,ATOP, f;'/,._Pe,r,..J<iOI',

p,M. NOP.TH P.M SOUTH

-I r-r---t-

.L E>L-. 1:,1!>1-1:,

11 ! 1,,,;.e,1-0" I

I I

/I

~t,.

'"<J

"' ru 0

a, 1,,_

I ti I

i

+

~

I/

':'.! ~

L

(\\J z

~ 1-ru 2:

I di Fl',i;c;,,..i Alp, ()!

u a

L....,...J 1-\\

~

T5AM HEATII""' C.011.

41 001;100~

O IH

¥.ADWA;;,T!o E,LD(>.

!,UPfLt FAN v4100 c.002

~

0 ?(1095]

1:.IN I

\\

3268 CFM i

/IP,l>/1 AND C.OP.. P,I DO I',

4351CFM ZO>ltc lt U

I I

I-.,

t ~EA II+

1712 <:,fM 1712 CfM

'ZONl: X ZOWE ~

t.1\\1<.!:A ~

Al>ANDONf;J:>

HOPPE.I' f'M, 1A:Jl INTAKE 8'

-+--~I

~I

!'}

t-~-9-l!<:)1L I

1,urP1-Y ~"N!> £ l/4'C IL

',, CH ~ r DRAIN l -

f Afl.E.A. 14

,,._e,L-E.

.- PP, f' A PIN<.,

AP.EC-'

2076.a~ "I "u:>N,~-~-

Ml: A 7 Alll!A c,,.

{

L C.!>N T l',I FU(; 5' P.,M,

(~l w

0 i+1 I

I\\

~

~ 0 ~\\

ru c.

~

~ ~u.

V ruro "Q

j

~

I %~AND e>YPA*;,, i,,,.,.,-,Pcf' V4*00FOI!!

\\00 "/* c:.APAC.ITY f-AC.H CHILLE..D r

--J..

/

CODL.11-lC..

H.,,r-1--....,,

V4100B007

  • I)

~

""'DWN:>TE !:>1-DCa,

,UPPLY F/>.N 1'4100 coo I

\\__ O.MUT orf DAMP!eP.,

V4i 00 FOi I WATE"r:

I F318 COIL)lf; l_;-..L-l~F319 I

1" V

~,

3'SZ F289 C:HIL.Le.0 WATE'P..

M-4953 <G-3l'>

12c:*ru"1--I V

{i l,

~I-

~1 f

\\I 0 "

s; 0

T 496 cfM t_ ___________

3425CFM __

3425 CFM 3425 CFM

-+__.____,

t :t I

I

_ ___ _1_71.._ CFM.J 1712 CFM NEW Fl L TER, l".M 124 Cl"M 802 CFM

'Z.G>>-l!!.. %

e>IST\\Ll.ATE SURG.E TANK i4,--. D\\'oTILL.&.TE SURG:iE. T.A.tb::.

M-4798

- )

~:12 (F-1)(

Al TE

~tt'.U/oLD - UP TANK.

M-4798 <F-7)

C-2)

~

A.IF!../

PARATOR M-4 798 (F - 7)

M-E>/Af', RllP1"llF1.E. DISC-All<

~79_8 (E:-f,_l.;:'.

j,,it--< M-2263 (F-6)

"T E'VAP. R.VPiURE:. DISC.

<M-2263 il:..::.§.' <

M-4945 (E-6) >

6:-L-1:,0 I 1* 0 11 t TM 20-0025 BALANCING DAMPER~

,n -

I E:\\..., b.01 1-to 11

'l'.

~

ro

...L.

.AAE1,e, fU E.1-POO I-FI I..-TE:;FI,, OEar-1lN, R\\ol.

149 O'M

-Z.ONe X

L__, __.,

I 149 CF'M L l49 <:.FM

--7 I L__

298 CFM

...L.

~

M'f:. A I ~

FUE::1- ?OOL.-

Fll-lE.P. r:,EMIN fl.NI 149 CFM zo.ie ~

r IL,,

00 M

687 CFM 836 --~FM 149~ t r -1 Jo."-E A 20 I

WA 1~ne:. DE:.MIN I

R,M 149 C~M

-Z.O>-lc X L_.

I 149 CFJ'I I

"-l~

273 c.fM 1804 CFM MOOUt.ATINu OAMPe,P, Hl(aH*EFI', FII..TEF-,-

V4100F030 r---,

V4100 DOOc,

-1 G--.... 1--1:

!>AMPl-f !>TAT'ION H

be>;)~TiP. !!,<HAUl>T FAN V4IOO '-00&

1431 Cl'M

!>AMI'~ -';,T/'IT'IOl'I EN(.~UP,&

<J+FM

,(S\\101,i,I Oi,I P41P l-lAOOl(A-4))

1861 CfN',

5211 c,,,,.,

a, M.,

ro

_I I

I 0 "f'M

~r-- --;8~~ - - - j - - - -

2-;5 ~M

~~ :tl--!1:!

2928CFM 3407 C Ff-'\\

~

~I I

-gll- - - -

347CJ'll- --;,7CFN,- r-: ~-=: ;t =~ f -

-=--1134 G,fM -=-=L- -=--~--:__ --=--=-2n: CFIA-==-;7rr '1.SCFlt\\

I r------11-'-, 00 \\i oo O" \\J I,

..1..

I i,..v..,... ~~

C.

u 0.,.

M

...L DUCT BLOCKED AND SEALED I..

~

\\J a

..b i:

IL v 0

t I

t I

I I

I-1240 e,;-,.,,

I Ji,--1

"-REA l'l.

7 AAEA l!:> t T/,!lll""'t t

t,._I\\EA. l!O

,._;...,, i&

"Hi:MICAI.

M!:DIC:AI.

'.Jr-Nl1DF\\

WE!>T ::OP.P.IPOI',

"-"!>T C.OP.PolC>OI",

I A"-cA 21 1

157 i:.Fr-1 I

I 157 C.PM I...,1,---

WM.TE COcl-.Cj r

fIPE> (,/\\~L.,\\>P.,'( I 1291CPM AND AflseA.

IG>

puMPAl!>L-E V/\\SY5 OF'e\\AATINC,

/>UA 2!o GONVl!.YOPi MOiO P, AP..cA 455 Crl"\\

A1'.!!.A 21#

co,.tV!: Yo"-.

DRUM c.APPINI,, AP-cA 3077C.FM ZONe X 0 C~M

__J iU~NTAl!,I.!:

,'\\l'eA 3077 <<;.Fr-,

Z.0>-11!. _.::;i:.

o_ -

__J e:vAPOR.AiO~

CFM I E.tr1>-u1>ER.

AJZ.eA 2267 CF'"'\\,

L.:;r-.1.e :x.

~ILiEI', !'oM, I

1291 <:.FM

,',.i"l.E. 1291 CfM 6T01'/\\C,Ei ""',

I Ci:C.ONTAMIN>:

40':>~T APoE" 1431 C:FM I

HJ!.A 397 CFM 83 C-fM 2069 crM 4194 CF,1 157 c.F'M I r -

-Z.QHE :C Vf.l E X

-z. ">I I: :2I

'------- ~ -----'

'%G)*.1e :a:

2e1,1a JI.

u, Ne :ir.

149 C.~M

~-r--=-=

f LOO!', PRA IN fll.'TcFI l'M, 149 C.FM ZONE! Z A"'-e>j_ 1. 2

-l-149 CFM I

I I

I

__J I

! 149 C.FM

~---~~

ft..OOF\\ OP.Al N DISMIN. l',M, 149 C.FM l-<>NI!. ;x_

"'"'ei,J. 1.?>

4-149 CFM L ____ _:l]~CFM ____ u_~f- -

-=:::...:.=-~'1.5 C.FM r---------1:::f1----- ---- ____ -:.: __ l:

41 CF!!_f.:'.\\A)(_r- _____ ~~-,\\--- ______

' _______ ~ ___ --~ _ -~

I

-- INF'll.~il:::N MA<. 1,......,1.;I'RA.'TION

---J---

---~

r---4J-----,

,-.-----~

t-.

~

~

O\\L COAll=$C.eP-..

!2

~

ETC:HlcD Dl!)c:;,,

E'!C11e;i, 01 l-cu~,c~..

fll.'T!e.P.. P..M, Fl,LTEF'. l"r,.!

COAL,-l!e!>G-~I',

430 CFM 41 c.FM Ml>,.',(,

41 U:M M/>..',(.

a,l'll'<.l i:>OR.

430 UM

'Z.ON?:: X.

'Z.ONE. :X:

'Z.ONI! :% I 430 CFl-1 A

AllE.ij_ 24

.i.n... _L 24 I 'Z.ONE.X I "'".1 24 AREA 24

~

..L

-+-

41 CFM M"'J.

41 CFM 83 C,FM NIA'/..

430 Cl'"\\V\\

___ ~O C.FM ___ _

TT I

_J I

I 83 l,ft,,(

_J

---~-----

Z.ONI!: :11:

I 1------~*

811 CFM 662CfM 513<:.!'M I

I I

II l:L. $e>ll>*o1 o:L.. S.&l>-o 2680 1:1""1 2680CFM 3896 C:.l"M 3896CFM 1117 CFM t

> M-2040 (G-3~

t

'I

'-<_ M-2040 <G-8) -(

c..VAP SURGE lAMK 405 CF\\.1

~

2515 i:.l"M

)M-2032-1 <D-3l >---t{

2780 C:FM

'FLOOR DR~ll..l ':>l.lMP 1

1 7

M-2222 <D-3))

l V

~

(8-4797 (B-6)<

W,._S1e S1'1-1PLIS. 1,._\\.I\\<.

v a..

Fl-I',. PPoA:"' T.~NK 1-- -

- - - 372C.;;; -


7

~

- - - -- ~:~O ;;~- -

- ;r-- - -- - - --

M-2033 (F-6) <_

I

,-----------------------11 ro r,-----------705C.FM-----------7 bl

"'"~;e c:c:1..1.1:.:.ToR Tl',.1 1

1 1 r - *- - - -*---* -- - -- - - - -,

1 ___

,n I c.e.Nil',1fua,e. Fe.Ee> TAN"-

,n 1

4 797 rn-:si<

Wl\\.,Tr£. MMPt..E TAlll<.

AN!"- ~4 A.1'.E A

~ eo

~

A Seo

,._._'!.A t6>A A"-!.~ !>I

~,,._ 31 T

I,.

-<f:1-4797 CB-3K I

AJ',!:A tB fl:~ C> TAN I'\\

t SVAPl'l',ATOP, WA.4;,Tf..

,...,._~,FIE.I', ~cur:t,t PUMP f\\OOM 331 CFi-1

'Z.O,l'I: X J

CHICMIG-"L, ""j,'ff.

C.ONDE.NS,,.TE C.ONt>l!.N,..ATE' 505 2192 f"l',lw{

}u 4384 Cf'M SPe..NT P.!e~IN

!>PESNT fl~IN C,;lNC.oNTl',AT~l>

C.El'ITP.IF'lll:>5 LJTIL.ITY PUMP P"'°'H. SLUDGE 505, *.,.

PHA"'1' p;;c.ANT CFM

---'--[7,

'7

~LLl""-l fl.~lf'C..

705 c.FM

~LLlfl.f',~ Di;LI\\IIT l',f<.iP\\'-. !'UMP fEE.C PUMP MA.t<IFOI-C

FsM, l"UM I' P,M.

_,.~

!'UMP f'-M, PLIMi' P.M.

PUMI' 1',M,

!")M *

,._M, AP.~ A, 513 C_.M L-----~

AAE._f ->,1 CENTRIFUGE FEED TANK WA~Tf; ',,N-11"1.ll' TANI'-

M= '21

!:t_ic_215 cc-n<

' F'-="' e>1',A1,-I 405 c.FM C.111..0RIDE. W~'!.TE,,._Ill<. 'f/M'Tf WUIC.*

2'>>1!! JC 372CfM 505 C.FM 505 c.rl".

,oP.l'IIDOP.

745 c,M 745 crM 372 <:FM 265CFM

~

2515-q,1"1 ZOI-I!: X

'tOt-11!. X --

2.<0IJE ::it.

I\\P.E""

't01'1!: ~

'ZOl-le :lC

ZONE :SC
  • zo1-1e :X.

Gill

'%<)Me :II.

RM.

513 CFM Z<>NI':' X I

I 1-'v-*-lv- --7

--'v-1------l 6577CF"l

'---~----'

1--------l

.1-.-~----'

l--4----'

..,23, 993.:.,OM I

993 CFM I

1 CFM TOTAi_

RM..

405 a,"1,4 rl

~

Q1-2215 (C-6)<.:

l.ONI!:. $.

WN,TE ~Ul1/4E TANI';

I r--------

I 331i:.l'M _ ---=-==---=-t-,---- i--i;~-

.----w..,11; A..l<r.A ?>'2.

filC.FMJ rt 1

"""Mrl.1'-,.,_NI'>

WIV,Tli P..1-i, C.1-Af'lflE" Tl',.

993 -'J" M l'."1

ZQl,IE -,C:

331i.Et1 Mi"'.]..,,,

.;-oi-, 1 X

-+-

...L

$.P"EiNi l's!!.<!; IN Tl',AN<,fE.P. l'UMP l',M, 331 '-FM

%.Of.IE _:,r.

l:

~

a

(\\J

___________________________.....zl

~-1--

1 1

SAMPLE (2002CFl¥\\i'-1lN"'fil<JJ I


_ ~O~C..:21_ _ ----- -- _j ~

I l-I ot C.Ol.lTA\\l,lEl<.VE.!:!!

I

\\JALL PENETRATIONS) 1 r

~

372 ~M w

M-5094,c-D I

7

.----~ ----1

~- -~

~

~

i

.---+~

f (

HU!A e,a,

,pf.NT P,f!>IN

~

J,Jl,ZA UA I()

,-. ~

A11-I!,._

~ I CONl>ISN..,.,Tli 1

SLURRY FEED

, -Z.-£ coN,a,rfM'TI,;,, !i: 7 >I'. i 7 Mf;Ti,;l',INt:> i>UM

~I f'\\INlli l),EeP'*

f T"NI'> !')>'\\.

.1\\-Z FE..D TANK N'I °' c 2 v !3 i:.ue,1,;.1.,E,

.J...

J P-M
  • PIPE TUNNEL 745 C.(M 372 'Ff-1 I- ~ 4.

w 2002<:..P'M 405 GFM 165'0 '-fM

%.DNl! :Jt

,c~

ZOI-IE X 2 ;;,-

.J ~ f-

-' ;J. >--

'.ZG>>E.:lC

'-HIEM IC.A!. '///,'?TE TAN I'.

1',"1

  • 165 c.rM U)14E~

-~

~

(J', 'Z~

~

.:z-:t"U..

l:?UJ

?UJ

.C.

-:t" i.\\,\\ili cl I

l..:..J

,,c( ~ ':>

4._ :E: >

_I. )_

z.01,1!!. :,c L

All~A...Z!IIA.

'i' >-

~ "'n

<>. o :z oz

~----=:;';--:;";t*--_, ti,

<-M---2-2-15-(F

___ 3_)_<~

3/4: ~t 4

ul

<ii

~

~

662 C..FM --

M-2222 (C-7) ~

lol----G ---<:. M-2040 (E-2is,'

~

~

COll.0 P\\\\A=E SEP I

) M 2240 I (C 4)>

r v I 2002 c;
M :j I

$.PENT f',EIPJN T NI',

WA'iT!. OIi-TANI'\\

,n b

q

~

2267 c.i=M a

M-2222 <F-7)

~

gk~~ ~h~2~~&~ RAT R 1,

~

Go I

ru

)M-2032 (D-3) >

r 6M721-4952 LATEST REVISION AZ 2275 CFM 1613 C..f""

f¥1',!l'ra C...MIP'II>

I',

1282.c.f'M c:.

w;:1-,.a.____

)M-2511 (H-1) >

1 705 C.FM 1117 CFM 1117 c..FM EQUIP\\'<\\'T. t>l".A\\l-1 SllMP

  • '1.. x] l/2" B!P2J4Wo~ SKID M-2511 (H-1) 1 1/2'

!'xi 1/2' LD\\J RAD EVAPORATOR SRI)) Cil122Y003 l'

M-2511 (H-1) ea.1-.,;,s7~.,.11 1 1/2' 1 1/2" 40 CFM SAMPLE BATCH TANK SKID Gll22Y008 M-2513 (F-3)

P\\B TANK SKID G 122Y004 M-2511

<F-ll HEPA FILTER V4100D110 Az1oco's INCORPORATED, THE FLOW NUMBERS INDICATED ARE HISTORICAL DES[GN VALUES:

THIS DRAWING WAS REfORMATI'ED BY MICROSTATION AT REVISION "Q". ALL PREVIOUS APPROVAL SIGNATURES ARE ON FILE ON MICROFILM IN DOCUMENT CONTROL TC A PORTION OF THIS DRAWING IS AFFECTED BY THE FOLLOWING; CHANGE DOCUMENT PREPARED BY INC.CODE T

DATE TITLE 1,1.. ;s1 1*"'*

NON-NUCLEAR SAFETY RELATED THIS IS A MICROSTATION PRODUCED DRAWING.

CHANGES OR REVISIONS MUST BE BROUGHT TO THE ATTENTION OF THE PLANT ENGINEERING DESIGN GROUP TO ENSURE THAT CONFIGURATION CONTROL IS MAINTAINED.

Detroit Edison Fermi 2 RADWASTE BUILDING HEATING VENTILATION AND AIR CONDITIONING FLOW DIAGRAM H

G F

E D

C B

CHECKED BY DATE OTHER REVIS IO NS:

I APERTURE CARD TITLE I A 8

7 6

5 4

ADDED TM 20-0025 AT REV. AZ PREPARED BY ZACH VlLLERS APPROVl!:D BY DATE I0-27-20 CHECKED BY

'Y'-~--

3 DATE

'0-27-ZP DATE

  • r.,,,--z.:t-ld EDP POSTING ENTRIES REQUIRE THE ADDmON OF THE ARMS STATUS CODE:

EITHER "AFC" OR "ASB" APPROVED _BY __

ATS OTHER APPROV, 2

RAD BLDG HVAC FLOW DIAG UNIT 2 PLANT IDENTIFICATION SYSTEM NUMBER V4100 DOCUMENT TYPE CODEDDDMEC

,. DRAWING NUMBER NUC OPS FILE NO.

1801 6M721-4952 1

ARMS RECIPIENT #

DATE tsSUED TO IS t[2-7IW'-O REV.

AZ