{{#Wiki_filter:H G F E D C B A 8 7 ~- - I R F STANDPIPE TYPICAL OF 6' SEE TYP, STANDPIPE F003C I LOI 2 1/2" I 4 F014C 5TH FL 4TH FL I 4 F012C 3RD FL I 4 FOllC 1ST FL 2ND FL I :: F006C F007C 6' BSMT I j F008C F032 TYPICAL 6' SUB BSMT, 10' C' TYPICAL~ F014A ~"-/ 5TH FL F012A 4 I 4TH FL FOllA.4 I 3RD FL F006A ~ F017A +/-' DRAIN VALVE 6' 2ND FL F007A F042 6' F041 FD03A ILDI F0041 IL I 6 I DETAIL 'El' lNSPECTR TEST I SPRINKLER (TYP.) \\./ALL ~ "7' ~ 6' 1
- PERNING 2" I.Al I
( I q I ~ ,, 2---1--o---G8---c.~. ---(I)-------1--{D-----2 L VALL OPENING ( I I I 1
- DRAIN DRAIN INSPECTOR I
TEST '. .I. .I. .1. ~ - F184 2ND FL MEZZ 4' BLOCK WALL 'w'ALL 1ST FL I _J 5 C7 2 112' 4 3 M-2135-1 <G-6) NSITE STORAGE BUILDING __J RAD\\./ASTE BUILDING SYS. DESIGNATI N VSOOO (SEE NOTE lD F012 ROOF F006A 11r *t 2 2ND FL 3* EL 623'-6' M-3843 F060 FD05D FOSS F070 DRAIN M-5329 F014 I LOI F015 ILDI F021 OJ] w
- a. "
F013 ~~ ]3/4' 0
- i:, '6*
c-; FD16 ILCI w °' "'
- a. "
0 ROOF T I 3/4' F005C FOllB 619'-9' 2ND FL 3' 3* 4* zsv ~ F038 DET. D F042 _23: F019* 12' ILCI w (L 0 F046 25 ~ @ 7 - - - - - -I -[r~c l'RFI I 12' IL I
- DET, E
F036 REF t> 2 10' F009C F037 IL I 1ST FL zsv ND15. 7 F139 AUXILIARY BUILDING SYS DESIGNATION PBOOO CSEE NOTE 11) MEZZ F004B !3' L I F028 BREAK ~GLASS VALVE I ~ FIR~ 2ND FL 1ST FL FO!OC 12* :B~ (\\J le ~ -' [() (\\J ' ,c 10' <j & C REF. M-2135-1 (E-6),_ _______ _,1 5 12' 1 I 2ND FL WU 4' FOOBAY BSMT I 14* F009A FO!OA S-BSMT zsv ~ F!SS s-----vT-i FL, EL. 5---.. . ~--,"' 6" Fl 78 ILCI F187 2ND FL 2' F129 F192 F14D 3' 2 1/2' F130 ILCI 'l PLUGGED 2 6' 2 2 F090B FIOl 3* ] M-4527-1 F103 F005A I CNil tL 6Ul' 6" F004A 14' []JlJ M-3843 +/-' 6' 6' F003A I 1ST FL 583'-6' FOOlA F067 FD02A 2* -~ FTT re, PI L431 F037 1 1/2' DRAIN 1ST FL FDO!B ILDI F002B wu F026 I F075 F025 j FO!O [bQ] F024 PT 4, 2ND FL L405 L 'w ROOF C" F023 E/V F006 F063 ' DOOl F027 F038 I LOI M-4526-1 6' 10' 6' I I F131 2' ~ j I.. DiT, [bQ] F132 3* I LCI 2f.:102 1 1/2' ~ 314* F.o,a I 114* R405 ~ p PLUGGED 3/4' VENT LC] F072 F038 I LCI -F023 PT FD51 8 i F0!4D .---""" [><J I-F032 I LOI 12* M-4526-1 FD33 RF 5TH FL. 4 1** F012D 4TH FL. FO!lD 3RD FL. 6' ILDIF045 12' a, 0 (\\J ID' F081 'SEE TYPICAL STANDPIPE F029 ILDI SPRINKLER PIPING
- 1ST FL 6, r SPRINKLER PIPING zsv F019 I LOI FT N007 1
.L412 FO?
- ,g 0 '
[f) f----y 6 1 7 DET. F021
- z::
C I LOI 1ST FLR, 0 © nrT A F022 4' M-4526-1 6' F103 t FlO! w DRN w VENT MAIN HEADER 2ND FLR CEILING FD34 [bQ] FOB2 LI SEE TYPICAL ST AND PIP 2ND FL, F044 F007D 1ST FL.
- t I 6' FOOSD BSMT 4'
F009D.i FO!OD SUB, BSMT. L _____ _ REACTOR BUILDING SYSTEM TSOOO CSEE NOTE lD 7 ~ ALARM CHECK* w:i:: VE 7 i I DETAIL 'B' 2 BYPASS ILOI RA05A-G FD65A-G 7 I I I FD36 IL I F005 I LOI 10* ~ 2' DRAIN GATE VALVE TYPICAL F003B [bQ] ROOF F024 u 4* 'F026 w F102 VENT F027 F054 I t,t ro31 6' 5TH FL, 4TH FL.I ~* F014B F012B FOl!B 3RD FL, F006B 2ND FL. 1ST FL, F007B 6' 4* u FSE N401
- BSMT, 2ND El 6'
F066 I F02S DET. I WU A ~ 6' 6' ~ FOBBA-G TD DRAIN. F039A-G I F075A-G BSMT. A ~ FOOSE i--**** FOOBE -0> "'... 7 SPRINKLER ,t_X..,., HEADER I IS LATl N VALVE ALARM CHECK VALVE L=DET Al1 'A~SE~ ABLD DRN I I _J I T. 2ct1~ ~ L ~--- _J ALARM CHECK VALVE DETAIL TABLE SPRINKLER IS VALVE P8000F131 (L ) T8000F030 (LO) TSOOOF020 CL ) T8000F023 (LO) PSOOOF128 CL ) T8000F025 (L ) T8000F028 CL ) XSOOOFDDl <LO) X8000F015 CL ) V8000F031 (LO) V8000F032 (L ) XSOOOF029 CL ) T w v23* 2041 CD F192 F058 FD62 F074 Fl88 FD54 F066 F108 Fl07 FD50 F054 F062 F193 F059 F063 F075 F189 F055 F067 F106 F099 F051 F055 F063 @) F194(L ) F060(L ) F064(L ) F076CL ) F190(LO) F056(L ) F068(L ) F105(LO) F095(L ) F052CL l F056(L ) F065<L ) FSE N401 0 P&ID @IDENTIFICATION ZONE @) F195(L ) F-6 P80RA04 RA03 F061CL ) G-7 TSORAlO RA09 F065(L ) G-7 T80RA12 RAll F077(L ) E-7 T80RA02 RAD! Fl91(LO) G-6 P80RA06 RA05 F057(L ) E-6 T80RA04 RA03 F069(L ) E-6 T80RA06 RA05 F104(L ) D-5 X80RA02B RA02A F096(L ) E-5 XSORADlA RAO!B F053(L ) G-5 VBORAOB RA09 F057CL ) G-5 V8DRA10 RAll F066(L ) E-3 X80RA07 RADS I ALARM CHECK VALVE DETAIL *c* ,~, 004A-I F087 ~RA06A-G I A-G DRN [ilj} F066A-G L AUTOMATIC ALARM VALVE (TYP 7 PLACES) DETAIL *y* CUB ) SCALE NONE SEE 0 DETAIL N/A I I I A I CA!T A A A A _J ASS ~
- -4
~ l t AL ARM 7 4' F009B FO!OB SUB BSMT, 7 2 DRN ")?SPRINKLER HEADER I 'I' ISOLATION VALVE I CHECK VALVE A DETA AIL 'A' (SEE TABLD _J FD64 BYPASS 7 1' 8000 049/ I I INSPECTOR TEST H TBOOO F105 F009E TYPICAL ARRANGEMENT FDR INTERPRETING INSTRUMENT NUMBERS IN TABLE 7 LI\\ \\E!?} M-2135-1 (D-6) I I ALARM CHECK VALVE A~~I DETAIL 'D'.,..-BYPASS i_'-c:070 1 ~ 0 SPRINKLER HEADER IS LATI N VALVE (TSO) I ALARM CHECK VALVE ;-lJYPASSI DETAIL 'E' / _J i ALARM CHECK VALVE rBYPASS DETAIL 'F' 7 i BYPASS L!J DRAIN F136 2 1/2' 6' F096 5TH FL! I, 6' F092 F093 14TH FL (\\J [f) 2 1 1/2' 3RD FL~F133 F135 5*Lt 4 3' 4' F134 F095 4* 3* M-4527-t F097 1ST FL. 6' BSMT F141 ' M I !M I I -*-,'@ F18~ ill] ti 3/4* f-J F!Bl 2ND FL MEZZ F094 ---~~~----- -- -- FTT L416 '--,./ 6' SPARE F086 ~2* FOOSH F007G 4' 2 112* F006G 2ND FL 2' 2 1/2' F009~ 3RD FL F042H PT
- 449, FD22
~ 14 1 I ~D [ FOOSG ~~ 4 IL I
- ~6\\1 FSE
,N47 F042G M-2100 2ND 4* SEE DTL. 'G' F005G [bQ] 6' 2' DJiJ 6' 10* F021 F009F FO!OF 4 I 3RD FL FOOS~ ~ 12ND FL FD05F DJiJ IL I F006F IL I F007F F052 u I ill F099F 4' 4' 4' F074 6'... cC DRAIN HIGH ROOF F035 16* I LO I FD14E [bQ] F016E 2 1/2 F007H F006H F005H IL I 1ST FL 4' F026J F069 2 1/2' _1_~ TURBINE BUILDING SYS,DESIGNATI N U8000 (SEE NOTE 11) ST AND PIPE THRU HIGH ROOP 2 1/2' * * ~ 14' F009B FOOSE F007B 3RD FL 2ND FL F005B 4' IL I F006B (\\J 0 a, (\\J r:i 7 2 1/2 1 L 'w ROOF F071 FD09C FOOBC I 3RD FL C' 6, FD05C 2ND FL RISER 1ST FL. 6, TD 3RD FL, [bQ] F007C F006C 7 2 112* HIGH R F F026K 4* ST AND PIPE THRU HIGH ROOF 7 2 1/2' HIGH ROOF F026L 4* ST AND Pl PE THRU HIGH R F 6' 6' 0 a, ru ' " FD15E 1 ' F017E 3RD FL I F009E FOOSE 2ND FL 6' I, L J 1 * (\\J 0 aJ (\\J ,c F006E FOlBE ] L 'w ROOF F036 ~------- F009D 3RD FL F008D 2ND FL F005D ILDI 12* DRAIN 6' 4* FD12D IL I F032 DRAIN DELUGE VALVES (TYP!CAU SEE D'wG M-5733-1, DETAIL *D~ F030 ZS ,N051)_WU FT FS U 040E 1ST FL 12' RADS (\\J 0 a, (\\J F090D CZ NE B6) FDR DELUGE VAL VE DETAIL D Le - 6' s* F029D DRAIN F090C F029C [iJjJ ~ ( ~T.) DRAIN I I 11 I I -'-{! " ~ F090B ~ F029B ~ -IN4D6/ I l'J
- 8.
'--..../ ~ 'c"'--, I ~ 11n7 (EN\\ l 12 I I PT L413 F029A 6' RA07 PT L412 7 LNIF064 i _l-{r DRAIN F090 I 13 I I -'-{! DRAIN I 5 & C REF 6) & C REF,'l) & C REF 6) & C REF,6) 4 3RD F006A F009A FOOSA STAND PIPE !ST THRU 3RD FL FT ,L43 [bQ] 4' F005A FD07A 12' VENT F024 (\\J 0 a, ru ' " FTT .L437;. 7 r-=--____,,e, BYPASS 3 5 6' F004G F075G L417 - ~O e I(:'. SEE DETAIL 'Y' CTYP 7 PLACES) __ _ _ _ _ _ _ T1 I & C REF, 10) FT FSE _/4,., FIRE 6' F013D j 4* F014D F015D,lXl- []JlJ !LOI FD17D FO!BD F004f F075F L418 N41~ _ ~ I @ 6 F040G I ~~9D (\\J 0 00 (\\J le F004E G' F004D z I _ I F004C ~ z]\\;IRE 7 FT FSE M F075E l!::41w411 Jro9i9 i i f ;_@ iiiii F040H F091.. 092 F093 F094 F095 F096 F09? INSPECTOR "]---- DRAINS TEST _/4,., ' I TYP, S LH_:[IRE (,'-:;-, 10 J F041E I 1@ F041G J I & C REF, 10h I I I LC I 6' SPARE F029 I ILCI ~ FT FSE _/4,., FlRE I @ L42 N414 L.!i:i I 19 /'jc:--~ F075B ~ hT - F041H j z i,2 - ~ PNL, U80P455 ::c___..$ SPARE esi'\\'-- U80P456 N4i7J-F020D 2 112* (\\J 0 00 ru ' 12' e; _,,--.,,r- ~ z]\\;IRE ru - @) ~ v,E/ V \\.----,Ir I -. L':J I l!J!J f;l(1 I I" _J F 42E FOO 7 /
- 1-----i F029F le -
z F031 F016D F003 FOO! F004A [jJjJ 12' [IT] I PT L451 >------~ DRAIN w t-I LOI 7 -"' ' s1---- [() (") - (\\J ' "'* F002 w L'.J _J w "
1t:J,-
~ -' [f) (") - ru
- k
- I THIS DRAWING WAS REFORMATTED BY MICROSTATfON AT REVISION "AW". ALL F063_,.cf,-"
I PREVIOUS APPROVAL SIGNATURES ARE ON FILE ON MICROFILM IN DOCUMENT CONTROL ~IN M-2135-1 (G-6i FIRE PROTECTION SYSTEM PUMPS & \\./ATER SOURCE 1
- THE FIRE SUPPRESSI N 'wATER SUPPLY CONSISTS F AN ELECTRIC FIRE PUMP
~ DIESEL DRIVEN FIRE PUMP EACH DELIVERING 2,500 GPM @ 150 PSIG, EITHER PUMP IS SUFFICIENT BY ITSELF TD SUPPLY THE MAXIMUM SYSTEM DEMAND, PRESSURE CONTROL OF SYSTEM
- PRESSURE
~ 'wATER SUPPLY lN THE CLOSED SYSTEM IS MAINTAINED @ 150 PS!G BY THE C NTINU USL Y OPERATING JOCKEY PUMP.
- THE ELECTRIC FIRE PUMP 'will ST ART -UP AUT MA TICALL Y 'wHEN THE PRESSURE IN THE SYSTEM DROPS TD 130 PSIG, DUE TD FAILURE OF THE JOCKEY PUMP TD MAINTAIN PROPER PRESSURE,
- THE DIESEL DRIVEN FIRE PUMP \\./ILL START-UP \\./HEN THE LINE PRESSURE DROPS TD 110 PSIG.
- SHOULD EITHER DR BOTH FlRE PUMPS START THEY 'will CONTINUE RUNNING UNTIL THEY ARE SHUT - FF MANUALLY VALVES
- ALL VALVES TD BE N RMALL Y OPEN UNLESS NOTED FIRE HYDRANTS
- MAXIMUM DISTANCE BET'wEEN FIRE HYDRANTS TD BE 300 FT.
- HYDRANTS TD BE LOCATED AT LEAST 40 FT. FROM BLDGS.
- HYDRANTS CAN BE USED FDR 'wASH D 'wN 'w!TH UT SOUNDING ALARM.
- AS REQU]RED BY TECHNICAL SPECIFICATION HYDRANTS ND, 9,10,11, 8.
12 ARE TD BE PROVIDED \\,/!TH INDIVIDUAL HOSE HOUSE. FLO\\./ S\\./ITCHES
- THE FIRE PROTECTION SYSTEMS INSIDE OF ALL BUILDINGS SHALL BE USED FDR FIRE FIGHTING NL Y,
- FL 'w S'wITCHES lN FlRE PROTECTION LINES 'will INDICATE USAGE F LINES AND SOUND ALARM,
- ALARM DR SIGNAL \\,/ILL BE MONITORED IN CONTROL ROOM NOTES
- 1. THE STANDPIPE SYS. IS DESIGNED FDR CLASS 11 SERVICE PER NFPA ND, 14 1976
- 2. ALL FIRE HYDRANTS SHALL HAVE A E,* INLET
- 3. THE HOSE ST A TI NS SHALL BE SD LOCATED SD THAT EACH SECTI N OF THE BUILDING 'will BE 'wITHIN 30 FT, OF A NOZZLE ATTACHED TD 100 FT. F HOSE.
4, STANDPIPE STATIONS N EACH FLOOR SHALL BE PROVIDED 'w!TH A 2 1/2' x 1 1/2' HOSE CONNECTION ADAPTER, 5, SEE Q,A,P,R, 30 FDR FIRE PROTECTION QUALITY ASSURANCE REQUIREMENTS. 6, 0 INDICATES SPRINKLER C NNECTl N 7, FDR YARD FIRE PROTECTION RING HEADERS SEE M-2125 THRU M-2130. B. ALL PJ,V,'s IN YARD SHALL BE LOCKED OPEN OR LOCKED CLOSED
- 9. FDR
- 1.
- 2.
3, 4, 5, 6, 7, 8, 9, 10,
- 11.
- 12.
- 13.
- 14.
- 15.
- 16.
17,
- 18.
- 19.
- 20.
- 21.
- 22.
SYSTEM FUNCTIONAL OPERATING M-2100 TURB. HSE 2101 l 2801 2802 2803 2086 REACTOR BLDG 2293 J 2294 2295 2554 R/'w BLDG. 2255 l 2256 2257 2259 2260 3400 3401 3402 3404 M-N-2051 2202-1 2130 SERVICE BLDG, J RHR COMP. ~ SKETCH SEE DVG M-5733-1 F /P RISER & SECT, F /P HI ROOF F/P BASEMENT F /P 1st, FL. SOUTH F /P 1st. FL. NORTH F /P DIAG. RISERS F /P HD'RS & RISERS F /P HD'RS ~ RISERS F /P HD'RS ~ RISERS PIPING ASS'Y BSMT PIPING ASS'Y BSMT PIPING ASS'Y 1st. FL, PIPING ASS'Y 1st, FL, PIPING ASS'Y 1st, FL. MEZZ PIPING ASS'Y 1st. FL. MEZZ F /P 1st. FL. SOUTH F /P 1st. FL. NORTH F /P 2nd, FL, OFFICE F/P SECT & DTLS FIRE PR T. P & ID FIRE PR T, PIPING FIRE PR T. PIPING & 2
- 10. = DESIGNATES ISOMETRIC DRA'w!NG NUMBER DR VALVE LOCKED POSITION EITHER LOCKED PEN DR LOCKED CLOSED AS INDICATED BY L DR LC, M-4526-1 M-4527-1 M-4542 M-3843-1 M-5033 M-5503 M-2135-1 PIPING ISOMETRIC -
FIRE PROTECTION SPRINKLER SYSTEM REACTOR & AUX, BLDG. PIPING ISOMETRIC - FIRE PROTECTION HOSE ST A TI N, REACTOR & AUX. BLDG, GENERAL ARRANGEMENT - FIRE PROTECTION REACTOR, AUX, RAD'wASTE BLDG. & G.S,'w.P.H. PIPING ISOMETRIC - FIRE PR TECTl N SYSTEM RAD'wASTE BLDG. UNIT # 2 PIPING ISOMETRIC FIRE PROTECTION SYSTEM RAD'wASTE BLDG. UNIT # 2 SF FIRE PROTECTION DIAGRAM - FIRE PR TECTI N SYSTEM (SHEET 2) lL THE F LL 'w!NG SYSTEM DESIGNATIONS APPLY TD THIS DRA'w!NG PBDOO X8000 UBOOO VBOOO TBOOO THESE SYSTEMS ARE NOTED SEPARATELY BY ENCLOSING THEM IN PHANTOM LINES AND NOTING EACH AREA BY BUILDING NAME AND/OR DETAIL NUMBER 'w!TH THE AREA SYSTEM DESIGNA TI N. UNLESS NOTED THER\\,/ISE EACH SEPARATED SYSTEM PIS NUMBERS 'will USE ITS SYSTEM NUMBER AS PREFIX IN THE F LL 'w!NG MANNER, ALL INSTRUMENT PIS NUMBERS 'will BE PREFIXED BY PSO (USO, XSO, ETC,) ALL EQUIPMENT AND VALVE NUMBERS \\,/!LL BE PREFIXED BY PSOOO CUSOOO, X8000, ETC.) I & C NOTES
- 1. SEE D'wG. 1-2488-01 FDR LISTING F REF D'wG'S, APP!CABLE DOC &
SUMMARY
DATA. 2,£ INDICATES ALARM N FIRE PR TECTl N SYS, MIMIC SEE I & C REF D'wG ND. 5 3, ELBD\\./ REQUIRED FOR ACCESS TD 4, SEE CECO FDR INSTR LOCA TI NS I & C REFERENCES l,
- 2. M-2000
~ 2001 LEGEND & SYM, 3, M-S-2000 & 2005 GS'w PMP HSE
- 4. M-2010 GS'w SYS. DIAG.
5, I-2030-01,02,03 FP.S. MIMIC PNL BOX. 6, I-2878-01 MAIN & S.S. TRANS. DEL. SYS 7, 1-2878-02 REG, TRANS, DEL. SYS.
- 8. I-S-2481-02 SID ELECTRIC FIRE PUMP
- 9. I-S-248l-03A SID DIESEL FIRE PUMP
- 10. 1-2878-43 'w ID DELUGE PNL. USOP455
- 11. I-2878-45 12, J-2053-02
'w/D 'w/D FIRE DET, SYS, PNL, X82P414 RELAY RM. CAB. H11PS29 [NUCLEAR 6M721-2135 LATEST REVISION BA SAFETY RELATED THIS IS A MICROSTATION PRODUCED DRAWING. CHANGES OR REVISIONS MUST BE BROUGHT TO THE ATTENTION OF THE PLANT ENGINEERING DESIGN GROUP TO ENSURE THAT CONFIGURATION CONTROL IS MAINTAINED. INC.CODE Detroit Edison Fermi 2 T>TLE T FT ,LOO! 800 1 iBAIDCD'S INCORPORATED: PREPARED BY DATE FIRE DIAGRAM PROTECTION (SHEET 1) SYSTEM ~ b' c\\. 5 SEE DET. ~IT -lT /~ " 34_ /1-..,----....._....., _17 I I I F061 1 2 BYPASS i 7 ,,,4 ) L-- ".J-------C A. PORTION OF THIS DRAWING IS AFFECTED BY THE FOLLOWING: H G F E D C B NSPECTOR ESTI I I El 7 /V8000\\ 7\\ DRAIN I INSPECT RI TEST SPRINKLER HEADER ISOLATION VALVE E-1-cl F062 DRN 3 ,,7 SPRINKL-v HEADER 2 SPRINKLER HEADER ISOLATION VALVE I TC CHANGE DOCmcENT CHECKED BY DATE !OTHER REVISIONS: APERTURE CARD TITLE ~ A IN 'I~~. 1 ~ SPRINKLER HEADEJ ISOLATION VALVE CV80) _J R 800 ~- L'l~V:NJ 1 F047 SPRINKLER HEADEJ lS LATI N VALVE CV80) _J "j IN
- ,\\ (:J-i~1s".> t'.YBOOO\\
1 @) LSPRINKLERHEADER ISOLATION VALVE CVBO) ~ DRAIN (TYP, 3 PLCS) _J I L ~ I ALARM CHECK VALVE DETAIL 'G' _<U~ _J ~:c~ ISOLATION VALVE ALARM CHECK VALVE L DE~L -~ CSE.:_! AB1:_E::_ h I __J I L 4 DRN ALARM CHECK VAL VE DETAIL '!' <SEE TABLD I _J A CORRECTED FSE T80N402 LOCATION PER DIAG FIRE PROTECT SYSTEM SH_l CARD 20-22469 PREPARED BY DATE ANDRE'w LE'wALLEN j 4-11-20 APPROVED BY David Kakoczki for T. Murphy llI n ATE <I /JBIZC. DATE '1' v;J'-" EDP POSTING ENTRIES HEQIJIRE THE ADDmoN OF THE ARMS STATUS CODE: EITHER n AFC" OR n ASBn APPROVED BY OTHER APPROVALS DATE ~ PLANT IDENTIFICATION SYSTEM: NUMBER P8000, T8000, U8000 V8000 DOCUMENT TYPE CODEDDDMEC DRAWING NUMBER NUC OPS FILE NO. 1801 6M721-2135 ARMS RECIPIENT # TO IS '//o1.P}}