8 P!Jw'ER AVAILABLE P£RMISSIVE VIEN RPS lllll[
SWITCH IS IN RUN DR STARTUP PIISITl[N RMS 611156-l ZNE G3 REF. 10 P£RMISSIVE UNLESS REFUEL PLATFORM IS OVER CORE AREA 8
I 7
P£RMISSIVE WHEN CHANNEL A REFUEL HllDE DNE RDD CONTRIIL SIGNAL IS PRESENT ZONE F7
\\
P£RMISSIVE VIEN All CHANNEL A RODS ARE IN 612110-1 ZONE D8 PERl!ISSIV[
VHEN ANY ROD IS SELECTED 612110-3 ZONE C6 PERMISSIVE W:N RPS lllDE SVITCH IS IN REFIIEL POSITION
)
RMS 68 I r' CHANNEL A REFUEL MODE ONE ROD CONTROL ZONES H7,E7 612110-6 ZONES E8,D7 612110-3 ZONES D8,D6 PERMISSIVE PERMISSIVE VHEN RPS MDD[
I r
I UNLESS GRAPPLE IS FUEL LOADED Q.DAD < 485 LBS)
PERMISSIVE UNLESS FRAME HDIST IS FUEL LOADED Q.DAD
< 400 LBSJ PERMISSIVE UNLESS TROLLEY HIIST IS FUEL LDADED Q.DAD
< 400 LBSl PERMISSIVE VHEN RPS MODE SVITCH IS IN REFUEL DR START-UP
\\
RMS GB
/
( AA '
612140-1 H7, SVITCH IS IN RLll PDSITIIIN
\\
RMS (cc' 612140-1 H6, 7
GB I 6
I PERMISSIVE VIEN RPS lllDE SVITCH IS IN RUN DR START-UP POSITION
\\
RMS G8 I ROD 'w'ITHDRA 'w' AL ENABLING SIGNALS INTERFACE 'r/ITH NMS REF. 9, SH.I 6
I PERMISSIVE IIIIEN CHANr£L B REFUEL MDII[ ONE ROD CIINTRDL SIGNAL IS PRESENT ZONE F7 PERMISSIVE VHEN RPS HOii[
SVITCH IS IN RUN POSITION
\\
RMS G8
/
( DD '
612140-1 H5, I
)
\\
\\
5 PERMISSIVE
\\/HEN ALL CHANNEL B RIJDS ARE IN 612110-1 ZONE DB PERNISSIVE VHEN ANY ROD IS SELECTED P£RHISSIVE WHEN RPS MIJDE SVITCH IS lN REFUEL POSITION RMS 68 I
< t"'cHANNEL B REFUEL MODE ONE ROD CONTROL ZONES H5,C5 612110-3 ZONES D8,D5 612110-6 ZONES E8,B6 P£RMISSIVE UNLESS RPS MDII[
SVITCH IS IN START-UP POSITION RMS GB P£RMISSIVE VH[N ALL RODS I~
rnAANDCH.B PERMISSIVE IN REFIIL MDII[ I lM ROD SELECTED P£RMISSIVE VHEN RPS HllDE SVITCH IS IN REFUEL OR START -UP I
)
I I
\\
)
P£RHISSIVE UNLESS REfUEL PLATFORM IS OVER CORE AREi,
\\
RMS GB
/
( BB '
612140-1 H4, 5
4
)
4 I
I 3
f EE" 612140-! D7, I
PERMISSIVE \\IIIEN SCRAN DISCHARGE WI.UN[ HIGH LEVEL TRIP IS NOT BYPASSED NEUTRON MONITORING SYSTEM REF. 9, 612110-1 2
( FF' 612140-)
D4, I
PERMISSIVE UNLESS SCRAM DISCIMG[
VDLUNE HIGH LEVEL TRIP IS BYPASSED 1
H I
G I
F
\\
RMS 611156-3
/
\\
RMS 6121:ifr3 I ZllN[ li5 ZONE u5 A DCD'S INCORPORATED:
ABN 12128-1 OTHER REVISIONS:
I REF. 10 PERMISSIVE VHEN SCRAM DISCHARGE VllUHE YATER LEVEL IS LO\\/
AUXILIARY DEVICE LOCAL REF. 1 CHANr£L A ANNUNCIATING ROD BUICK CONTRll REV. 0 P)~ BY 4.MLKA DAT£ CHECKED BY DATE DATE 3
CR A
,12110-3 ZONE F5 I/\\
,12110-4 ZONE G7 C
I
\\
ROD OUT BLOCK C650 THIS DRAWING WAS REFORWA'ITED BY AUTOCAD AT REVISION "A~, ALL PREVIOUS APPROVAL SlGNATURES ARE ON FU.B ON MlCROFILM IN DOCUMENT CONTROL TC A PORl'ION 05' THIS DlUWDm IS AFFECTED BY THE FOU.OWJNO; CHANGE DOCUKERT I
REF. 10 PERMISSIVE VIEN SCRAM DISCHARGE VIILUHE YATER LEVEL IS LDV AUXILIARY DEVICE LOCAL REF. 1 CHANNEL B ANMUNCIATINli ROD BLIICk CONTROL 612110-3 ZONE F5 612110-4 ZONE G7 NOTE: SEE 61721-2110-1 FDR NTES,REFERENCES AND LEGEND.
INC.CODE u
TITLE PREPARED BY DATE 161721-2110-05 LATEST REVISION A
NUCLEAR SAFETY RELATED THIS IS AN AUTOCAD PRODUCED DRAWING.
CHANGES OR REVISIONS MUST BE BROUGHT TO THE ATTENTION OF THE PLANT ENGINEERING DESIGN GROUP TO ENSURE THAT CONFIGURATION CONTROL IS MAINTAINED.
Detroit Edison Fermi 2 LOGIC DIAGRAM CONTROL ROD DRIVE HYDRAULIC SYSTEM PART 5 E
D C
B
>---------------<A APER.TURii! CARD TITLlil CHECKED BY DATE r===r=========t==:;;:AP~PRO~VED1iii1:]1BYL+/-::J.cm::::: ~2,f,l~NT!E!.frf.YSS~£M.~YSTEM p ART ~
RECIPIBNT #
CllOO EDP POSTING ENTRIES REQUIRE THE ADDlflON OF THE ARNS STATUS COl'.IE:
l:l'l'HER "IJ'Cf' OR "ASll~
OTHER APPROVALS 2
DATE DOCUMENT TYPE CODEDDDINC DRAWING NUMBER NUC OPS FILE NO.
1801 61721 2110 05 1