3 to Updated Final Safety Analysis Report, Drawing, 6M721-2015, Diagram Station and Control Air
ML21055A133
Person / Time
Site: Fermi, 07200071  DTE Energy icon.png
Issue date: 02/02/2021
From:
DTE Electric Company
To:
Office of Nuclear Reactor Regulation, Office of Nuclear Material Safety and Safeguards
Shared Package
ML21055A091 List: ... further results
References
NRC-21-0002
Download: ML21055A133 (1)


Text

{{#Wiki_filter:H G F E D C B A I 8 7 3/4~ F018A r------------------------------------------------------------------------7 '*INDICATES VENDOR P5001D003 SUPPLIED VALVES VENDOR SUPPLIED AND EQUIPMENT INSTRUMENT A TI N 1

  • CONTROL 21

,,- AIR INTAKE FILTER* N COMPRESSOR SKID I PANE~ / =~~--~~ I F2220A I _.L P50N542 P50N550 I I P50N543 P50N551 F2222A rev P50N546 P50N554 IAS f1fC 1st STAGE COMPRESSOR P50N54B P50N557 SUPPLY

Lc--

W/ INTERNAL INTERCOOLER PSOR49o 1 F22J7A c r-----------J F2219A "CA" 7 ' F2208A

  • F006A 2nd STAGE COMPRESSOR 1

r3387 re F2228 b 3' ~ _J R401 L ~ H21 P408 IFTH FTL ( L405 V-----1 L404 A FE A ,.---.i N400 A FTL L402 A FTH L403 A I I I I I I I I I I I I I I I I I I I I I I I I I I F2221A ".Q~ -~Y". W/ INTERNAL AFTERCOOLER 6" 1 1 / 2 2' ~ ',1' I H-'....,--r i-:------1.---4<1-.L..,-;-r---E:--------, 4---+0!-;'k:,+--"Y 1 "-.J 3,, 6" 6' F2218A F014A" F015A TBCCW RETURN i I F2205A T8CCW SUPPLY 3/4" LINE STOP l<M-2008-1 {8-3) f- - - - -) F2203A--<M-2008-1 (8-3) ( F044A 1 ~ 4" AIR BALANCE I _h------",_,--'-"""---, 1 /2" f2206A L NE (TYP.) F2204A ,,~, / F2200.1,_-~f, 1 2

  • OIL HEATER~::=J I F2~0~:-1 133871 1 4,, ~

OIL COOLER

  • DRAIN 1 / 4" YOf----.~D::;;R~Al;;-N --:;:TR;;;A-;;;P(;:;;TY;;;P'. }-T--:::

F2207A WEST STATION Al R COMPRESSOR P5001D003 I I I L ______________ _ FDR VENDOR SUPPLIED INSTR SEE INGERSOLL -RAND D'w'GS CED!S N FILE N.)1 D8889L <Pl-15445) ____________________________________________ J D8889AI.' (Pl-15446) //,----------------{}-----[AI-D8889GA <Pl-15447) F018B DRAIN ~_L4'


7 i

P5001D002 VENDOR SUPPLIED l 1*INDICATES VENDOR /\\ INSTRUMENTATION I

SUPPLIED VALVES AIR INTAKE FILTER N COMPRESSOR SKID 1 AND EQUIPMENT I _L; P50N544 P50N552 I

F2220B

  • C NTR L:

FCV

  • P50N545 P50N553 1

B PAN Ee PsoN54 7 PsoNsss 1 IAS F2222 1 F1070 1st STAGE COMPRESSOR P50N549 P50N556 1 3387 r:, SUPPLY

c...--

B W/ INTERNAL INTERCOOLER P50R491 ! F2217B "CA" "7 l F22D88

  • i ___________ _j

~- F2229 1 F2219B 2nd STAGE COMPRESSOR I FOOSB F2221B =-c-- ,;;~V, W/ INTERNAL AFTERCOOLER 6" 1 l/2 2* I "IA" N ti I I I I FQ148

  • 3 I

FQ158 6 i TBCCW RETURN F2218B F2205B TBCCW SUPPLY i 3/ 4" <M-2008-1 (B-4) f- - - l._ _cl r2Z03B-~M-2008-1 (8-4) ( 1 /4AIR BALANCE I 1 1/2' 1 L(NE (TYP.) F22048 LC, f F044B LINE STOP 3' F2206B F22DOB F2202B 1 2"== DRAIN 1 2" I 3387 I l/4"

  • OIL HEATER 1! -

F2201B y FI071:t 1 OIL COOLER* DRAIN 1 I L--K>f-------===---f-~~ I I I f2207B

  • DRAIN TRAP{TYP.

CENTER STATION AIR COMPRESSOR P5001D002 L ____________________________________________________________ J FOR VENDOR SUPPLIED INSTR. SEE 1.' RTH!NGT N D\\o/GS-1.'3 46300GN, SK-22864,EDIS N FILE ~Bll-117 & Bll-149 FOlBC \\Ml r------------------------ -------------------- -------------------7 FILTER II SILENCER P5001D004 ~ FOO~C: 3/4 1

-
5 UNLOADER INTERCD LER CONTROL 8'

3387 ~ F006C ~ TBCCI.' ~ If) 00 e, L".' TI' R020 I\\ C / 133871 r33s7 3' ~ I~,_ H21 P408 FTL 1--1 L404 FE B ,.-~, N400 B FTH L403 B FTL L402 \\ B 6' VrJ\\ _J R40t L ~ H21 P408 FTH FTL L405 /,---.._\\ L404 C FE C N400 i-~ C FTL FTH L403 f C ~ L402 ) C ' - (PSE PT ~ r- - N002 L426,- "" \\ C C '--..::;=-';--1-'-f-+ 1 ,.._~_.., 6' r, s* 1 r I I AFTf5R0~~~~~r #l § ~ 5' I 6' f-L::-{e_,J,,-~'.1-<-i I I I 5 H21 P468 ~~~ ~--~ ~ I 1 PSE ~ I r-- N001

,...,'4-_j 1

~ C 8/4' F004C O I 1' I µ..C..Lj STRAINER O H21 PSOOlDOl 9 I P468 F963C ":::~::,:'. 112* 1/2 6 ! ,..-L.. PTT L401 C rv - ,D I w - z R R

i
,

3/4" 6' F015C LI l'.le'.'. R009 F"OlDC ~ C ti TBCCI.' T 3/4' 1/4' FOl!C C:3;4, F012C P43 I ~=~131_/.4_4'..' ~isr£~ill E.ST A TI N AIR COMPRESSOR (SPARD

13387 IF967 I

f-1' F964C rm~ 1/2" (I') ~ I L50l r,~-- FOOSC TBCCI,' C YI 3585 1 I 1??S SCFM I\\...:./ A: 1 .. 1 1 j >M-CUUl::i-1U1-:i; ) P5001D001 + IL I I .A. DRAIN I I ___ F063C _______ J L ________________________________________ ------ F868E 1' 1'

j.

DRNT ~-- l' S T F013C

314, Psooi~i/~ER I 33871 T

T\\o/T L409 C SPARE [- I' 1 FLR.DRN <D-7) 3/4' F966 1 112* SPARE [-(}--+-V} F868F F869D SPARE SPARE [--,

)

'+ 0 {-.., .L 133871 '~ INSIDE OUTSIDE F2013 r T.B. TB. AUXILIARY AlR SUPPLY TD STATION AIR RECEIVER, ~ ,D Q F2012. T I 1/2' LJ ~---<6' 3/4' fgl_: ~ :;:r2010 El F2014 F20B /

  • 2

-I -Pl R005 B

x PT L009 B

~ r~----------------------------1 I I I I I GRUP *c~ GR UP "W GRUP 1c* GRUP *o* GROUP TV L432) ~ j <SEE NOTE 6) (SEE N 1TE 65 TS~ I N426 B EEC\\./ TSE F2D7B SEE Dw'G. N425 El M-5357 B 1 1:.'...J I Tl,' L431 3/4'1 I LI'----- B F209B F20BB 3* 3' AFTERCO LER 3* ,..-,4"

  • c~I GROUP 1 D"

~ (SEE NOTE 6) C, co.,. I c, WW ,:w DZ 7 ,----r---------------------------------1 I I I ~ I I GROUP 'CtGROUP 'D'1,G/* GROUP 'D' .-l_ (SEE NTE ff' (SEE NOT1E TSE\\ I N426 A F207A ~ EEC\\./ SEE Dl.'G. M-5444 TSE ( N425 A

  1. 65 GROUP *c:1 GROUP *w r--------

(SEE NOTE #6) WW TV L432 \\ T t\\/4' L431 I T\\o/ n J rLJ A xw DZ cc u_N 3'..-,4' I,', L 21 PErl 0 ~ ~ ~ ~ w Q ~C-LINE F017B f---~:__----1 ~TOP 3/ 4 1 F022E 9., P5002B005 i 3' !lo;

  • 3308 I t' 3'

F209A ,A v~ F208A I V C 3' f.,C_ AFTERC LER P5002B004 '-J 4' GI

c. L~

2 PSE ~ LJ ~ Q M ~ _r;, ~i2.. _ 10£' LINE STOP rj,_ ST A TIDN l/<' AIR RECEIVER P5001A002 F04 7B 8 I F2009 ~ M v, F016B 3/4' -1VL ~23 2053 F042B I 3606 I P5001 D023 F043B 3/4 1 DRNT l' STRAINER P5001D022 F965B 1/ 2' y @_ / PXE ~-\\N533 F026 E 2' F974 ' v" 3' ~ '.3/ 4' ~ f.J MOISTURE F210B DRN l'J SEPARATOR F210DI i ~ ~ l'J Q F1001B P5002 D029B P5002-D028 F1002B EEC\\./ "-J* "' u SEE Dl.'G, M-5357 lti" EEC\\./ SEE D1.'G, M-5357 F201~ I ~ r--- F201D ) 100 SCFM t/4' F210A. DRN ~ .----r RD 7 8 B / PT N481 ~ PSE........_ MOISTURE SEPARATOR V 1' ( ) F1001A P5002h D027 F1002A 112* f-- 3307 F201AJ.;;; 1....----..1 PI I K'ozs/ ~ EEC\\,' SEE D\\o/G. M-5444 EECI.' SEE D\\o/G. M-5444 PT ,.L-1 PSE' 100 SCFM L012 ~ N481 A A I E i 1/4' I DRNT ~-_J3/4' F204B1' I 1/2' F206B DIV II CONTROL AIR COMPRESSOR <DIESEL GENERATOR PDl.'ER) P5002D002 L012 B.JI - ) l-2451-05 (G-6) ) B 7:".:::___________ LO IL PRESSURE TRIP DIV I CONTROL AIR COMPRESSOR (DIESEL GENERATOR PO\\./ER) P5002D001 L_,jc-:l _-c2c-4~5~1--0~4~(G~-~6~)-) DIV I CONTROi_ AIR AUTO START P5002 D029A ~ LO IL PRESSURE TRIP r----- DRN F1003B ~ BLD\\o/DD\\o/N IN CAP HOLE r----7 1-2451-04 (F 6) ) I I 3308 I I I I I I I I I L-------------------------- I --7

a.

I I °' I A I I 17~s;_ I E/V ~ 1' A / ~ E/V F516 I 1-2451-08 I ~ F517 A ~. -,, --;:.._ 1 SHUTTLE H21 VALVE P501A -- rial~* F2261 0 .-~J-4>-- NIAS zsv N440 A&B ~ T--MA778 ~ PXE N403 I\\ A/ PT L410 A 33077 3' 1/46 l I DRNT y _...:-7 DRN

    • II F1003A 3/4~

F204A BLOl.'DD\\o/N HOLE _.r IN CAP F206A C ~~~1-M_, _" -H-1 ------)- /s~1\\& ~~ I PTH 01 3307 I l><Jr--r-C DIV. 1-NIAS CONTROL AIR DRYER P5002D012-AIR DRYER P5002D014-PRE-FILTER P5002D016-AFTERFIL TER 7 ~ 33097 I I F215A i F216A I I GROUP 'C'I GROUP 'D' GROUP 'D'I GROUP 'C' 54621 3' 2' -v 3' 2' TV L453 A s> I I I I I ~ L __ DE _______________ 7 z

~... *;.cio'i::i.~,t~~40 3*

3* 2* ~zv ~ 2"1 <t: <t: ~~ ~~ ,I,~ ~ I I I 1 1/2' 13' T F282 i-I M-5737-1 I ( 3' I ZSV ~ @i I N407 31 I i P~T3 I 3307-!A I A I 33108 Jl 2 L 1 I 3308-lA 3' 3' 3" I I I I I I I 3* ,........ l I I "I - V.... V "l I I 2' IF211A FD F402 IL I

r-1:~~-~lE.

,-e--, SHUTTLE ITr1 I .VALVE ~ F2262 F2260 l.'M-PSO-7613 2' 1 1/2' HOSE CONN. FDR I w - fnE L_ _ _..::-j i:,...,:;:..:=rJ.,.-PORTABLE AIR 2' s> 2~. 2i~:e::*

  • (;l

~ ~ ~~ ~ = ~ ___ ruru ___ ru f N NN ru N ~~ ~ 0 ,---:i 1P50021 I ' !., 1 TI038Bt-: r 'i ' l J IF5o02i -I Li o37Brc 1 L I l.'.r If" \\ J ~ ,--7 I P50021 -{ f 1n38M-7 f-l.r *RJ Rj ~~ Y ipSo02l I I I r-TI037At--- f-l.'.17-I \\_) i;J---l-0 z TE N463 A LO REFER TD ~ GIC I 1,;.,-* I-2450-01 Q 1 ! 2 I I,,I PSE N415 I,' PSE --fill : I I I I ITT - ,D.,. I Im F212B I I I I I N>---- r.c=c-, : F2 l1B r-< CRPB ( : I I-24~-11 I I I I I : K CRPB ( r7-1-s~

1'""

E/V G~f,UP I GROUP 'D' _,lf:HI COMPRESSORS Q I " 15 K1101D002A & D002B A NON Q PDS =--,:!<J-_J N513 t ~f41 PTH B (t¥')TT 112c' PTL L'm DETAIL *A' <B-3) (TYPICAL FDR D037A ~ rn SE D037B, D038A &- IJ038B) PT L415 ~450 ~

  • ro I

I I I I lf ~/~ L. E

473 IA GROUP 'D' I [iRUP 'C' NON Q QA I 1... 'y F516 LO B

~ H21 <M-5737_1 <B67 L418 -~ L512 L400 ---~ E 5463 B B 3308 F215B I DIV II-NIAS CONTROL AIR DRYER I Tl,' L453 B N B 16 HI L8 NO!O I'- A 0 ~ 0 ~ 0 ~ w 8 I (EIV ~~01 E/V c-------; F002 f-...__@ I '\\.' og3 A

w. ST ATI N AIR COMP. PANEL CSIMILIAR FDR CENTER & EAST COMP. PANELS) rn VENDOR SUPPLIED AND MTD INSTRUMENTS FDR A >

AIR DRYERS OH! P5002D012, 14 16 P5002D013, 15, 17 3' 7°F219A Z F220A E/V F511A E/V F"512A E/V F513A E/V F514A E/V F515A PSE N511A PSE N512A PI R411A PI R412A PI R413A 7E1V E/V F511B E/V F512B F513B E/V E/V F514B E/V F515B PSE N511B PSE N512B PI R411B PI R412B Pl R413B fL ' "~ ~ u~ " "s "'w 5> u-' " PT L450 / T l 1 1 I I I I j H21 I 1 D4T !AS ~: I -~ P501B P5002D013-AIR DRYER }---l..;:::r:::~---'------------------1 p;ggi~~N~;;~~fRnt :r[~ 1 3309 3* F222A s.

F223A

~. F433 A,/ ~w "_j oZ, (X) c, zsv ,,,~ I N536 ---~ I ~ I A,B a:: L___ PSE PT L410 B L-""----r{>(c-J"-1):'.1:J-'=,[f--{>(h, B PXE I K A943 F216B GROUP 'D'I GROUP 'C' GROUP "C'I GROUP PD" I 3., F1041A 4: r-- N482 1 ~ Pl I F473 F1041B [51- 'f N403 Rags I L~~l F,C, ~! b - E __ J 3* l\\r.o'M-58461 F1006A I oW If) RSOO --~ ""'.':_:'.___-::~--,-;:::;:::=:;--:::=::------~L----~="~~-[X}--------1 I '---./ F1041C u o r I 3 6 D I B RV L _________________ 7 t::~ LO PTH LJf'----1 PDS 3 I

==7 <:I: ~ L515 N537 N404 i I F1006B 3* AIR DRYER P5002D030A ~ Fo20A PSE

r( CRPB <

~ ~ H2 l ~ EAST INTERRUPTIBLE CONTROL LO>~CJ-11-2451-11 I 3' P378 r4'-'-IXJ---l,..."r-'~-i P5002D034A PRE-FILTER (r --~- 1 I F1037A t1031A P5002D036A-AFTERFIL TER "' l -#1 ~1fJp L~~o L.._ ___ 7 \\./EST INTERRUPTIBLE cNTRL 3, I ~ 1------; 1 AIR DRYER P5002D030B 1 M F017A 314.. , -l)(f.1..C..---1 '---'r7..l.se7 ~-'-"i P5002D034B-PRE-FILTER I

\\

r-CME I P5002D036B-AFTERF"IL TER I ~i.:i.:. STATION ~ R404 3~ I AIR i--:--=:i><c-=- '- ".'-.LJ B i F1037B 19Ff5"s46] L '-j.;--F-2230 J RECEIVER F047A i* I r P5001A001 "---,--...J I F1031B 3 H~ 1 2" 016A ,----.1 I 2' I 3606~.s,r-~==~G--~===-~ L+~~,~---

  • --~

~-~T;. STOP _ _, '----c~'ic:-vj '-~c--¥ ,""--'---+- ~," N538 F042A 1-2\\~1 I ~ H21 FD43A 2' 1 EXHAUST 2* \\f DIV ll CONT AIR COMP 17INLET VALVE UNLOADER/ jRVI F219B :t F220Bz till F221A ~/ I 3309 I F~21B --;::;"; F222B ih£J i~-1--~~~ F223B J / { M-461' "

, U.J- /)

f-- I I I I I I I ~f.7 r c",{,":, V B PT L IO )- B L"'.+/-j I ~- 7 Np4-:8~~~ I I PT \\Ne' L 11 1"' B

  1. 2 CONTROL AIR RECEIVER P5002A002 1

r M-4615 (G-4) > I/ PI' R410 I-I\\ B / F228B 12, ~ 130261 3 DRN. 2058 GROUP ~u* GROUP *c* 1384§ 2' v PEN END 1384§ 3' zz ~ M-4797 <F-6) /

  1. 1 CONTROL 0'1.+/-,

AIR RECEIVER P5002AOOI I N3 2' F228A r@+---$--7 PT LOlD A 4 DE ,(E I I I I I /pr L011 A I 3026 I I I r~~~J 4 Pl R410 . A / DRN GROUP 'C'I GROUP 'D' 91~ ~~ 1* F535 ~ j: P378 1384@ 3, zz DRNT I F536 er, O', Kt-c!;r" ih V23 154071 00 OJ 3/4, q:=:p ~-~ I 3 F1046 D O 2055 2' ~ '- V23 I ru ru PT 3 r--=-----,-----=7 .----1 2007 1/ 2* T~ r-- c--~-----

i:
k G41 r

~ V23 c-='--"'--./'/ LSlO L7 f-------i !AS PNEU SUPPLY L401 V23 ' ~-'-< ~ 'efufi'/'--,,1, 2'Xl/2' 2058 ~ ~I~ ~I~ 1/2" J., G1100 F2147 V'l GHOO TO LOW RAD EVAPORATOR SKID G1122Y003 M-2511 (H-82 I CONTROL AIR COMP PANELS I P50-P401A <DIV D I P50-P401B (DIV ID E/V-F433A PSE-N483A PSE-N481A PI-R410A PI-R078A E/V-F433B PSE-N483B PSE-N481B PI-R410B PI-R078B 0 §

jO:'.

20ll 2' \\ RED, INS, 1/2" M-4797 (F-3) ~ "-./ F965A i:i:i4:a::.lf'l F1038 i 00 oo [!] Ji I TE ~ Wo ~ "=I" 1/2" I co I N520 ~[52:~ F1051 Ln in 1/2' 154071 l" t* 2"X3/4' RED F?42B ~ M 1

  • STRAINER _J

'- _/ D::: Q,'. 'd 25 I -----~ ~~:'...l...D-{,,fS===:,,..!._....J. __ tKl---"--J V 23 I 3/ 4 R HOSE CONN (Y) P5001D015

,----s
7 Q,'.~w

-l:c(f---LtM-4615 1* x 3/4' BUS:H'G 2011 1 ~--~~~ ~ F, l!ll; ¢r Dll 408 REFER TO~ Y' I-2181-03 ¢r D11 ~ i 3007 I f-ro PI PT ~gO:'.[: ~ " 1" PLUG b;s§e--c s3/4' HOSE CONN,. @fil 3, ~~~~/f~s, L___ STJJ1~~J~~R ~ R482 L517 V23 k--h'SEE'-J 3, H21P465 D OJ I,: 'v DRAIN 2055 H21P4b6 H21 --,,t--°'~ 1' 1

  • F839k V23 V23 GllP013 P378 2*

00 "X314,, BUSHIN ~ 2054 2053 F1044 (J', 3 "=I"

0:

V23 HOSE ~ 3/4';;; 2 1/2' 2005 CONN'S V23 v 23 STATION AIR H21P462 H21P463 Gl!P022 1* f§ 2058 2005 ~ I 1*X3/4'BUSHING l'Xl/2' ~ ~ lIB_j BLACK

GALV, 3*

I BUSHING V23 2055 ru js4 sl V23 V23 2 2058 2058 i::j I"--" IM I I I


~ I I

r I STATION AIR L_j STATION AIR _j H21P461 I G11P020 Gl!P016 00 1 112* <-f4M ~55-i419933-;c:EE::-T7>>7'--i7:_-,-ll 1-- ~ sz ~ F732C ~PEN -7 I I I I I I 1' 0 u..___-'- 2' ~~ ~*,,..~ 55t gj V23 ~ 2~5-8 3 HOSE CONN'; J 2~x3;4~ BUSHING 3/ 4" F2149 i OPEN PIPE BLOWOFF l6W>,1-Gll-0884-l ?i:x3/ 4';:'-3/ 4"x!/2" t/2 G1100 G1100 TO HIGH RAD EVAPORATOR F2148 SKID G1122Y002 -t><};) M-2511 (H-5) ) TO CARBON BED VALVE RACK SKID (G1122Y005) SEE DIAGRAM 6M721-4615 FDR C NT!NUAT! N OF IAS B. NIAS PIPING D 'w'NSTREAM OF CONTROL AIR RECEIVERS. 314.. ~F:2145 f 3/4"x1 2" <111do 3/4" ~ OSE CON ECTION ~AIR FILTER rBASEMEN~ CO!. U/18 M-2512 (C-8) ) NOTES: IU 2' ,---AIR COALESCING

1. UNLESS OTHERWISE SHO\\./N1 FILTER ALL INSTRUMENT PIS NUMBERS ARE PREFIXED P50 F866 F867 ALL VALVE AND ~QUIPMENT PIS NUMBERS ARE PREFIXED P5000 1 ~rc--txcf-'2,_'--i 1'

" 2U03P3PE(RC 8 ) 2, \\./HERE POSSIBLE ALL INSTRUMENTS TD BE LOCATED r 1*1-IN ACCESSIBLE AREAS. ETCHED DISC FILTER 3. CONTROL AIR COMPRESSOR CMC S\\/ITCHES LOCATED BACK\\o/ASH SKID IN MAIN CONTROL ROOM AND NORMALLY PLACED IN N E G1102Y001 AUTO P SITl N, CONTROL AIR COMPRESSORS TO BE M-2033 (C/D-8) STARTED IMMEDIATELY ON NORMAL PO\\./ER AND LD\\./ER \\./HEN DIESEL GENERATOR LOADING PERMITS ON F868 1 EMERGENCY P l.'ER. F869 4, IAS DENOTES INTERRUPTABLE AIR SUPPLY, TD REACTOR BUILDING 3' SEE D\\./G 6M721-2085... I F868C F F868D 1 1" :I 8' (TURBINE BUILDING 1ST FLOOR HEADER) 00 154081 I F?3JB 2 112* r-F735B I ~~1 I 6 5, NIAS DENOTES N N-INTERRUPTABLE AIR SUPPLY.

6. QA LEVEL I FDR NIAS PORTION

'I --------""Fil35,,7"'03"'5ccA'" 2, FLOOR~ { 3RD COL ROI.' 2ND J!O !ST F036A FLr *** I F037A 1---------,, FLOOR 3;4*ZF038A F033 v~ 2' F039AI 3/4' F034A* 16' TD REACTOR BUILDING 6 SEE D1.'G M-2085 TD RHR F040 !ST FLOOR F037B M-N-2055 (B 7) ~ COL ROI.' KB s IXJ F135 ¢ V'J 2* F138~ F140C ::$: _., F139C COL ROI.' K5 F141C F038B C L{3RD ROI.' F039B l,. 1/2' K7 2ND CDL{3RD ROI.' KS 2ND 3/4' F035B FLDR -

  • , I I

, A 2" I FLOOR ~ F036B F034B F035C FLR - FLDR~ 2'1 ro;;;c~ 4' F034C 1---- 1ST FLOOR F037C COL ROI,' K4 F038C 2' 2' I F868B 6' 8',- ' F034L'7 12" 1 4' F035J _., 3RD FLOOR F036J .., 2ND FLOOR F028 .,-3RD F035H F137 3' FLOOR L--

-----i)<\\--11 TD

--LINE MACHINE STOP F500 SHOP F139F.. F139 ~ F139G 2, F037H _., 1ST >- CDL RD\\./ M12 COL RD\\./ -< R7 2ND ~~M-Jr3/4= F034K F036 Fl40F $: F140E 40G ' I, COL 3/4 1

  • F038H FLOOR.,1 1..-.lST F037G FLOOR -i:*

3/4'¥F038G F141F :t COL ROI.' MlO F035F a, (3RD FLOOR - 2' ROI.' MS F141E ~.,) 2ND F036F FLOOR - COL RD\\./-< e---l M2 a L ro29J u BASEMENT -h TYPICAL DRIP 3/4:z;<,.F030J LEG SEE DETAIL 18 N Dl.'G {_. M-3009---,i F031J,1,. 112* ~ COL RO\\./ M6 ,I,. F141G F039H F035D 1/2.. 2' F034G 'V'J '3RD FLOOR I I F035E 3RD FLOOR - F036D 2ND FLOOR -12' F037E C-1ST FLOOR - F03BEZ COL{ F036E RD\\./ 2ND FLOOR... ~ 2 7 M6 F029H FD BASEMENT 11><1-, -j F140D 314 COL F030H ROI.' 6 F035G '3RD FLOOR - 1/2'1 F039G F036G COL t2ND FLOOR - ROI.' F037F R2 c*~t-1-;;-, 1ST FLOOR

  • 2'

\\F 034F 3/4# F038F F~~-EI I I F~: 1D F034E~. F031H I :z F034H 1/2' 112* F039F $:r34J 3' 4' 2' L_J"~-----SERV!CE AIR TD CND 1, POLISH DEMIN F029A 3/4'f F030A 112*1 F031A CJ"' zw CDL ROI.' L14 I 2801 F524 v~ M-2011 CJ R R _J _J "' "' w w f-z 2 ~ 3' zz -'w TD GEN SERV, TD C!RC. \\./TR PUMP HSE :r: PUMP HSE, '3I "'f-w Z zW M-S-2024 M-R-2027 1 112* i:r:iw F032 [)! (.-') 3N =>" 1----,>(f---~---, f- "' 1 1/4p F396 F139H .., Fl39B f-'>. +,F139A ¥F140B F039C: ZFo34D 112* 12* ~01; ~ 398 F399 I 3326 I c,,---> M 2006 cD 3) > 3;4* F397 P1100F179 ZF395 . F140A z F140H Ir141A ,1,.F141B tF141H 8 F037D - A '-J 314 1 "-- "'1 acW R-' $'.,F 38D.J.- FIELD ROUTED TD RACK G11P021 F039D I COL ROI.' L1 3/4'..,, F029G F030G 1/2' F031G CDL ROI.' P2 7 3/4' -'+,F029F F030FZ 1:¢

8:Fo96 3'

--- F029E F029D L 1/2' F031Fi 3/4' 3/4~

  • F030E F030D TO CONDENSATE BACK\\./ASH TANK ~

M-2011-1 1/2' (C-2) .a,.F031E 112** .a,.F031D COL RD\\./ R9 COL ROI.' R4 COL ROI.' RB 6 ~F029C ~I zro30C ~ 1/2' CDL IF031C ROI.' Rll 3/4' f--* F029B F03 Bz: 1/2* ,I,. F031B COL ROI.' R14 5 I " - ru D D OJ I > I X \\.,,, \\123\\ ~ v, V'l 112~ PI ~ 3*zz I 11 I ~ I A V23 ~ ~1 1/2' sz 2053 ~ E IU <>---9 N 'su6'11FS37B N IU (~~~) z ~ F837C M-2031 <D-3)) 1 #x112* 8 ~ I 1/2* BUSH'G M-2031 (C-4)) 1*x3;4* BUSH'G (\\J Xo V23 ~ 1r GALV. 2054 ~BLACK 3/4' HOSE (') D OJ I,: N OJ '-- F837A ~ u R I f-OJ 2',()(1 2*x3;4* BUSHING V23 2058 e--:l==-1 -=2-* m 1

  • coPPER TUBING

< PEN) 154101 (v2~ ~ 3/4' F840D l'Xl/2' BUSHING F865 1 'X3/ 4'BUSHING V S 1384§ BLACK I GAL V, 3.. zz 2' F839E 154081 F840C v~ V'J1*-....'-..I NlE 2' 154081 ~ V ---2* E<>N<>E 2 V',1..-... F839F 2'SZ [ 2'X3/ 4' RED, INSERT 2 1 x3;4* 2' CONNECTION 3-HDSE CONNECTIONS I ~

I i I I ~ ~

l l l MULTIPLE N E E N N E HOSE CONNECTIONS £_yd_ ~ 2'X3/4' BUSHING '<'.F749 V23 2058 z ~ _J ~ w z ~ °' °' <1: r 3' 5982 'j J--...'.:::::::r::::,_-"1,-.H 2' 3RD P5000F2233_,/ I J-2 P5000F2232 P5000F2234 STATION AIR SERVICING TURBINE OUTAGES 4 Q"7 (J-~ L,C-,J r-r, FLOOR l(PDI' \\!Sit 'B' \\. PIS# 'A' P5002DD37A P5002D037B P5002D038A P5002D038B DETAIL 'A" <REF, F -2,3) PTS# #El P50R874A P50R874B P50R875A P50R875E cs1DCD'S INCORPORATED, OTHER REVISIONS: F838F STATION AIR H21P414 I __ _j PIS# 'C' P5000F2251A P5000F2251B P5000F2253A P5000F2253B PIS# 'D' P5000F2250A P5000F2250B P5000F2252A P5000F2252B THIS DRAWING WAS REFORMATTED BY MICROSTA.TION AT REVISION "BR", ALL PREVIOUS APPROVAL SIGNATURES ARE ON FILE ON MICROFILM: IN DOCUMENT CONTROL TC A PORTION OF THIS DRAWlNG IS AFFECTED BY THE FOIJ.OWJNG: CHANGE DOCUMENT CARD 20-30663 PREPARED BY APPIWVED BY 10 3 DATE /0-1-1.0 DATE Jo~z-20 EDP POSTING ENTRIES REQUIRE THE ADDITION OF TSE ARMS STATUS CODE: EITHER "AFC" OR "ASE" RA03 1' BUSHING PREPARED BY CHECKE_!? BY J,,E>PROVED BY OTHER APPROVALS ? REFERENCES 7, FDR SYSTEM FUNCTIONAL OPERATING SKETCH SEE M-5730-1 THRU M-5730-7, 8, DELETED

9. D DESIGNATES ISOMETRIC DRA\\o/ING NO.

(PREFIX ND. 6M72D DR LOCKED PEN/LOCKED CLOSED VALVE POSITION AS INDICATED BY LO DR LC. M-2000 FDR ABBREVIATIONS M-2001 FDR SYMBOLS I 6M721-2015

,wvr~TON I-2450-03,-04,-05 VALVE LOGICS M-2085 ST A TI N AIR RISERS LATEST..... *-*-..

cs

  • 'w' RTHINGTON D'w'G N, \\J346300 GN I-2450-01 STATION AIR COMPRESSOR LOGIC DIAG, 1-2450-02 CONTROL AIR COMPRESSOR LOGIC DIAG.

M-5357 EEC\\./ DIV.II M-5357 RBCC\\o/ M-5444 EEC\\./ DIV.I M-2008 TBCC\\J SYS, D\\./G, INC.CODE T DATE D_ATE DATE DATE TITLE NUCLEAR SAFETY RELATED THIS IS A MICROSTATION PRODUCED DRAWING. CHANGES OR REVISIONS MUST BE BROUGHT TO THE ATTENTION OF THE PLANT ENGINEERING DESIGN GROUP TO ENSURE THAT CONFIGURATION CONTROL IS MAINTAINED. Detroit Edison Fermi 2 DIAGRAM STATION AND CONTROL AIR APERTURE CARD TITLE DIAG STATION AND CONTROL AIR PLANT IDENTIFICATION SYSTEM NUMBER P5000, P5001, P5002 DOCUMENr TYPE CODEDDDMEC NUC OPS FD.E NO. 1801 DRAWING NUMBER 6M72l-20l5 1 ARMS RECIPIENT # DATE ISSUED TO IS 10\\'5\\ioio REV. cs H G F E D C B A}}