SAFEGUARDS INFORMATION HOLTEC Krishna P. Singh Technqlogy Campus, 1 Holtec Blvd., Camden, NJ 08104 DECOMMISSiONING INTERNATIONAi..
Telephone (856) 797-:0900.
Fax (856) 797-0909 10 CFR 50.90 10 CFR 50.54(p)
October 05, 2020 ATTN: Document Control Desk
. U.S. Nuclear Regulatory Commission Two White Flint North
_1_ 154_5J~ockville Pike Rockville, MD 20852-2738 Pilgrim Nuclear Power Station Renewed Facility License. No. DPR-35 NRC Docket Nos. 50-293 and 72-1044
Subject:
Physical Security Plan Revision and License Amendment Request to Incorporate Alternate Measures
References:
[1]
Letter, Holtec Decommissioning International, LLC to US NRC, "Notification of Revised Post-Shutdown Decommissioning Activities Report and Revised Site-Specific Decommissioning Cost Estimate for Pilgrim Nuclear Power Station," November 16, 2018 (ML18320A040)
[2]
Letter, Holtec Decommissioning International, LLC to US NRC, "Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations," March 31, 2020 (ML20091M858)
[3]
NRC Interim Staff Guidance, NSIR/DSP-ISG-03, "Review of Security Exemptions/License Amendment Requests for Decommissioning Nuclear Power Plants," September 28, 2015 (ML15106A737)
[4]
Letter from Holtec Decommissioning International, LLC to U.S. Nuclear Regulatory Commission - Pilgrim Physical Security, Training &
Qualification, Safeguards Contingency Plan, and Independent Spent Fuel Storage Installation II Plan, Revision 19A to Support NRC Review of the Physical Security Plan Revision and License Amendment Request Incorporating Additional Independent Spent Fuel Storage Installation dated July 22, 2020.
Pursuant to the provisions of 10 Code of Federal Regulations (CFR) 50.90, 10 CFR 50.54(p),
10 CFR 73.55(r), and 1 O CFR 50.4, Holtec Decommissioning International, LLC (HDI) hereby NOTE: THE ENCLOSURES TO TIDS LETTER CONTAIN "SAFEGUARDS INFORMATION', AND "SECURITY RELATED INFORMATION'. THE ENCLOSURES AND ATTACHMENTS MUST BE PROTECTED ACCORDINGLY. UPON REMOVAL OF THE ENCLOSURES, THIS LETTER IS DECONTROLLED."
HDI-PIL-20-076 Page 1 of4 SAFEGUARDS INFORMATION Sob/
NHssz~
- J£L 1v1055
SAFEGUARDS INFORMATION Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 HOLTE C ----------------
oecoMMissioNING Telephone (856) 797-0900 I NT ERNA TIO NA L Fax (856) 797-0909 1-------t-c:qtJeS men pe ammg to the Pilgrim Nuclear Power Station (PNPS).
Physical Security, Training & Qualification and Safeguards Contingency Plan (PSP) and a proposed revision to License Condition 3.G, Physical Protection.
The proposed changes reflected in the enclosed Pilgrim Physical Security Plan (PSP) introduce an alternative measure with regards to the physical protection of Spent Nuclear Fuel (SNF), from radiologici:1I sabotage and/or theft. Specifically, the proposal is a change in the defensiv~ ~tr-_at~gy.3he changes would implement a Nuclear Regulatory-commission (NRCfapproved alternative measure as allowed by 10 CFR 73.55 (r} "Alternative Measures".
Specifically, the proposal is a change in the defensive strategy. The change would implement a Nuclear Regulatory Commission (NRC) approved alternative measure as allowed by 10 CFR 73.55 (r} "Alternative Measures". This License Amendment Request (LAR) will show that the process and measures utilized for the protection against radiological sabotage and/or theft of SNF with regards to the Pilgrim Nuclear Power Station (PNPS)
- Protected Area (P/A), meet the same performance objectives and requirements as specified in 10 CFR 73.55.
The proposed changes are appropriate for a facility that is performing the "DEGON" method of decommissioning and is within the descriptions provided by the Post-Shutdown Decommissioning Activities Report submitted to the NRC on November 16, 2018 (Reference
- 1) and is aligned with the revised schedule provided in the HDI Annual Report on Status of Decommissioning Funding for Reactors and Independent Spent Fuel Storage Installations submitted to the NRC on March 31, 2020 (Reference 2).
The proposed PSP is consistent with the guidance provided by NRC Staff in NSIR/DSPISG-03, "Review of Security Exemptions/License Amendment Requests for Decommissioning Nuclear Power Plants" (Reference 3).
Pursuant to 10 CFR 50.91(a)(1), HDI has performed an evaluation and determined that the proposed amendment presents no significant hazards consideration under the standards set*
forth in 10 CFR 50.92(c), and, accordingly, a finding of "no significant hazards consideration" is justified. Furthermore, HDI has evaluated this proposed license amendment against the criteria for identification of licensing and regulatory actions requiring environmental assessment in accordance with 10 CFR 51.21 and has concluded, pursuant to 10 CFR 51.22(b), that no environmental impact statement or environment assessment need be prepared in connection with the proposed amendment. to this letter provides a summary and an evaluation of the proposed PSP which is based on Revision 19A (currently in the NRC approval process). Attachment 1 includes NOTE: THE ENCLOSURES TO TIIIS LETTER CONTAIN "SAFEGUARDS INFORMATION', AND "SECURITY RELATED INFORMATION'. THE ENCLOSURES AND ATTACHMENTS MUST BE PROTECTED ACCORDINGLY. UPON REMOVAL OF THE ENCLOSURES, TIDS LETTER IS DECONTROLLED."
HDI-PIL-20-076 Page2 of4 SAFEGUARDS INFORMATION
HOLTEC DECOMMISSIONING INTERNATIONAL SAFEGUARDS INFORMATION Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax(856)797-0909 1--------=e---fle--->>'ign1f1Cafrt-hazards-cons1 era I0n etermination and environmental review conclusion. to this letter provides a markup of the current PNPS Rene~ed Facility License to reflect changes to License Condition 3.G, -Physical Protection. Attachment 3 to this letter provides the retyped (clean} page of the proposed license condition change.
- Enclosure 1 to this submittal contains attachments that are "Safeguards Information" and "Security Related Information" and must be protected accordingly. Disclosure of Safeguards Inf<>rmatio_n i~ prohibited by Section-147 of the AtomicEnergyAction of 1954 as amended.
Security Related Information is to be withheld from public disclosure pursuant to 10 CFR 2.390. Enclosure 1 provides a description and evaluation of the proposed PSP revision, including a description of programmatic assumptions applied to the development of the proposed PSP based on 10 CFR 72.212(b}(9}. Enclosure 1 also includes a summary of the alternative measure requested pursuant to 10 CFR 73.55(r}, descriptions of key design features of the proposed PSP, and a list of Orders applicable to the PSP with cross references to relevant PSP sections.* contains "Safeguards Information" and must be protected accordingly. This enclosure provides the Pilgrim Physical Security, Training & Qualification, Safeguards Contingency Plan, and Independent Spent Fuel Storage Installation II Plan," Revision 20.
This is a revised version of the PSP that was submitted via Reference 4. is a compact disk (CD} that provides an electronic copy of the above referenced documents. As such, the CD contains "Safeguards Information" and must be protected accordingly.
HDI requests approval of the proposed license amendmentby March 31, 2021. Once approved, the amendment will be implemented within 30 days.
Pursuant to 10 CFR 50.91, "Notice for public comment; State consultation," paragraph (b}, a non-safeguards copy of this submittal is being provided to the Commonwealth of Massachusetts, Emergency Management Agency.
This letter contains no new regulatory commitments.
If you have any questions or need further information, please contact me at (856) 797-0900, ext. 3813.
NOTE: THE ENCLOSURES TO TIIIS LETTER CONTAIN "SAFEGUARDS INFORMATION', AND "SECURITY RELATED INFORMATION'. THE ENCLOSURES AND ATTACHMENTS MUST BE PROTECTED ACCORDINGLY. UPON REMOVAL OF THE ENCLOSURES, TIIIS LETTER IS DECONTROLLED."
HDI-PIL-20-076 Page3 of4
_ SAFEGUARDS INFORMATION
SAFEGUARDS INFORMATION HOLTEC Krishna P. Singh Technology Campus, 1 Holtec Blvd.; Camden, NJ 08104 DECOMMISSIONING INTERNATIONAL Telephone (856) 797-0900 Fax (856) 797-0909 1-----'-------t---eeelar-e--ttnder the pe11alty-uf perJury that the forgoing is true and correct.
Executed on October 05, 2020.
Sincerely, A d L
~
olgned by Andrea L stenf,s n rea *. ~~~=.:t':.';;Sterdls,c=US, St d
- Decomrnlsslonlng titemallonal, er IS
=~~~~I~~;
Andrea L. Sterdis HDI Vice President, Regulatory and Environmental Affairs Holtec Decommissioning International, LLC Attachments 1. Summary and Evaluation of Proposed Changes (uncontrolled)
- 2. Proposed Change to PNPS Renewed Facility License Condition 3.G (mark-up)-
(uricontrolled)
- 3. Revised PNPS Renewed Facility Operating License Condition 3.G (clean copy)-
(uncontrolled)
Enclosures
- 1. Description of PNPS Physical Security Plan Changes - (Safeguards Information)
- 2.
- Pilgrim Physical Security, Training & Qualification, Safeguards Contingency Plan, and Independent Spent Fuel Storage Installation II Physical Security Plan, Revision 20 (Safeguards Information)
- 3. Compact Disk, Containing Enclosures 1,2, and 3 (Safeguards Information) cc:
(without Enclosures 1, 2, and 3)
NRC Regional Administrator - Region I NRC NMSS Project Manager (Pilgrim Nuclear Power Station)
Director, Massachusetts Emergency Management Agency NOTE: THE ENCLOSURES TO TIIlS LETTER CONTAIN "SAFEGUARPS INFORMATION', AND "SECURITY RELATED INFORMATION'. THE ENCLOSURES AND ATTACHMENTS MUST BE PROTECTED ACCORDINGLY. UPON REMOVAL OF THE ENCLOSURES, TIIlS LETTER IS DECONTROLLED."
HDI-PIL-20-076 Page4 of4 SAFEGUARDS INFORMATION
HOLTEC Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 DECOMMISSIONING iNTERNATIONAl-to HDI Letter HDI-PIL-20-076 Telephone (856) 797-0900 Fax (856)797-0909 Summary and Evaluation of Proposed Changes to IIDI-PIL~20-076 Page 1 of7 (8 pages including ~over page)
HOLTEC Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 DECOMMISSIONING INTERNATIONAL Telephone (856) 797-0900 Fax (856) 797-0909 Summary and Evaluation of Pro osed Chan e!S__ ___ ~-------------------c-1.0 Summary of Proposed Changes This proposed change to the Pilgrim Nuclear Station (PNPS) Physical Security Plan (PSP) reflects the introduction of an alternative measure with regards to the physical protection of Spent Nuclear Fuel (SNF), from radiological sabotage and/or theft. Specifically, the proposal is a change in the defensive strategy. The change would implement a Nuclear Reguiatory Commission (NRC) approved alternative m~~~ure as allowed by 10 CFR 7'3.55(r)-"Alternative-
-Measures": Thislicense Amendment Request (LAR) will show that the process and measures utilized for the protection against radiological sabotage and/or theft of SNF with regards to the PNPS Protected Area (P/A), meet the same performance objectives and requirements as specified in 10 CFR 73.55.
The proposed PSP was developed to meet regulatory requirements for protection of the spent fuel against the design basis threat of radiological sabotage. The* proposed PSP is designed to meet the physical protection requirements for protection of spent fuel stored in the Spent Fuel
- Pool (SFP), and the existing Independent Spent Fuel Storage Installation (ISFSI) storage pad, as well as in the new ISFSI II storage pad.
. This proposed PSP requires prior NRC approval PSP LAR (Reference 1) submitted on April 2, 2020 which added the security protection requirements applicable to the new PNPS ISFSI II
. storage area._
The proposed PSP is consistent with NRC guidance provided in Nuclear Security Incident Response/Division of Security Policy - Interim Staff Guidance (NSIR/DSP.:.ISG)-03, "Review of Security Exemptions/License Amendment Requests for Decommissioning Nuclear Power
.Plants," (Reference 2).
The proposed PSP addresses Orders previously issued by the NRC which are applicable to the current Pilgrim PSP.
2.0 Applicable Regulatory Requirements Pursuant to 10 Code of Federal Regulations (CFR) 50.54(p) and 10 CFR 50.90, Holtec Decommissioning International, LLC (HDI) is requesting approval of proposed Pilgrim PSP and an amendment for a conforming change to PNPS Renewed-Facility License Condition 3.G. In accordance with 10 CFR 72.212(b)(9), the proposed PSP is required to protect spent fuel against the design basis threat of radiological sabotage in accordance with the same provisions setforth in the physical security requirements of 10 CFR 73.55 with certain conditions and exceptions as specified in the regulation. This submittal includes requests for alternative measures pursuant to 1 O CFR 73.55(r), 10 CFR 50.90 and 10 CFR 50.54 that support the proposed PSP revision.
3.0 No Significant Hazards Consideration Determination The proposed PSP revision addresses the physical protection of material on site that is licensed under the PNPS Renewed Facility License, as well as the general license for the PNPS ISFSI. to HDI-PIL-20-076 Page2 of7
HOLTEC DECOMMISSIONING INTERNATIONAL Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 PNPS has submitted the certifications~or 1 o GER 50 82(a)(1 ), (RefereRre-3t-ther-efor-e-t-he 10 1-------.CFR Part 50 license for PNPS no longer authorizes operation of the reactor or emplacement or retention of fuel into the reactor vessel, pu~uant to 10 CFR 50.82(a)(2).
The proposed amendment incorporates an alternative measure per 10 CFR 73.55(r),
"Alternative Measures" as the regulatory basis for the proposed change. The* modifications associated with this proposed amendment include removal of three buildings on site fo allow for better line of site and interdiction of adversaries, minor modifications to the interior of buildings to-strengthen fighting positions; and enhancing existirrg security' intruder deforrenffeatures.
around the site. HDI has evaluated the proposed amendment to determine if a significant hazards consideration is involved by focusing on the three standards set forth in 10 CFR 50.92, Issuance of Amendment, as discussed below:
- 1. The proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated.
Response: No PNPS has submitted notifications pursuant to 10 CFR 50.82(a)(1) for permanent cessation of power reactor operations and permanent removal of fuel from the reactor vessel. Upon docketing of the 10 CFR 50.82(a)(1) certifications, under 10 CFR 50.82(a)(2) the PNPS Part 50 license no longer authorizes operation of the reactor or emplacement or retention of fuel into the reactor vessel. The irradiated fuel at PNPS is currently stored in the SFP and within the ISFSI on a single pad.
In this condition, the number of credible accidents or transients is significantly smaller than for a plant authorized to operate the reactor or emplace or retain fuel in the reactor vessel.
Construction of the second ISFSI pad is in progress and scheduled for completion in the fourth quarter 2020 to allow for complete off-load of the SFP to dry storage in casks within the new ISFSI II storage pad.
The proposed amendment would have no significant effect on facility SSCs and no significant effect on the capability of facility SSCs to perform their design functions.for any accident previously evaluated, it does not significantly increase the likelihood of the malfunction of facility SSCs and does not increase the probability or consequenc~s of an accident previously evaluated.
The casks are maintained in ~ccorqance with the provisions of the general license for the PNPS ISFSI, utilizing the Holtec International HI-STORM 100 Cask System, Certificate of Compliance (CoC) No. 72-1014, and in accordance with the associated Cask Final Safety Analysis Report (FSAR). The HI-STORM 100 Cask System consists of spent nuclear fuel (SNF) residing within a fuel basket structure contained with.in a sealed metallic canister, or Multi-Purpose Canister (MPC).}"heHI-STORM 100 receives and contains the sealed MPC for long term storage, and provides gamma and neutron shielding, ventilation passages, missile protection, and protection against natural phenomena and accidents for the MPG. Cask FSAR Chapter 11, "Accident Analysis", to HDI-PIL-20-076 Page 3 of7
HOLTEC Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 DECOMMISSIONING INTERNATIONAL Telephone (856) 797-0900 Fax (856) 797-0909 Section 11.2 provides the evaluation oiaccidents for::t~~8-Gask-Systei11 w Ic satisfies the following minim1.,1m acceptance criteria:
The MPG confinement boundary maintains radioactive material confinement, The MPG fuel basket structure maintains the fuel contents subcritical, The stored SNF can be retrieved by normal means, and The system provides adequate shielding.
The Hl~STORM 100 Cask Sy;te~ p~ovid~; the spent nu~lear fuel and radioactive material in storage with confinement, radiation shielding, criticality and passive heat removal, independent of other facility SSCs.
The modifications associated with this proposed amendment include removal of three buildings on site to allow for better line of sight and interdiction of adversaries, minor modifications to the interior of buildings to strengthen fighting positions, and enhancing existing security intruder deterrent features around the site. The proposed security modifications do not significantly affect the ability of the Cask System and MPG to perform their functions as described in the Cask FSAR. Hence the proposed amendment has no effect on the ability of the Cask System to perform its design function nor would it increase the likelihood of an acciden(previously evaluated
- 2. The proposed change does not create the possibility of a new or different kind of accident from any accident previously evaluated Response: No The proposed amendment does not involve any physical alteration of any facility SSCs or Cask System components required to mitigate or prevent any accident previously evaluated, and does not have a significant effect on the capability of any facility SSC or Cask System component to perform its design functions.
Thus, the proposed amendment does not create any initiators or precursors of a new or different kind of accident than previously evaluated. Likewise, the proposed amendment does not create the possibility of a new failure mode associated with any SSC malfunction or personnel errors that could result in a new or different kind of accident.
Since the proposed amendment does not significantly affect any Cask System components; the credible events for the ISFSI are not changed.
Therefore, the proposed amendment does not create the possibility of a new or different kind of accident from any previously evaluated.
- 3. The proposed change does not involve a significant reduction in a margin of safety Response: No Pursuant to 10 CFR 50.82(a)(2), the 10 CFR Part 50 license for PNPS no longer authorizes operation of the reactor or emplacement or retention of fuel into the reactor vessel, therefore the occurrence of any postulated accidents associated with an operating nuclear reactor is no longer credible. *
- to HDI-PIL-20-076 Page4of7
HOLTEC Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ oa1*04 PECOMMl551C>NiNG INTERNATIONAi-Telephone (856) 797-0900 Fax(856)797-0909 After all fuel is removed from the ool and saiely stored in dry casks-u:a-eittler:-tSJ;Sr-1'.p};:aH'ld1------
ocatIon, a postulated fuel handling accident is no longer credible in this configuration~
The proposed amendment does not involve a significant change in any facility SSC or Cask System component's design, configuration, or operation. Therefore, the modifications associated with this proposed amendment do not significantly affect the capability or manner in which facility SSCs or Cask System components perform their s*afety functions, or the safety margins associated with their design and function.
Therefore, the proposed amendment does noJ_involve a_significant reduction in a margin-of
- *safety: *- - * - -
~ --- *.
4.0 Environmental Considerations HDI has evaluated this proposed amendment against the criteria for identification of licensing and regulatory actions requiring environmental assessment in accordance with 10 CFR 51.21, and determined that it meets the criteria for categorical exclusion set forth in 10 CFR 51.22(c)(12). The proposed amendment is being submitt~d under the provisions of 10 CFR Part 50 for approval of a safeguards plan and changes to the PNPS Renewed Facility License, and in accordance with 10 CFR Part 72.
Activities associated with the proposed amendment do not involve any significant construction impacts, and are consistent with the plan for future reduction in the security area that focuses primarily on the storage for spent fuel,- described in NUREG-0586, "Generic Environmental Impact Statement on Decommissioning of Nuclear Facilities," as a general activity expected to occur during decommissioning. The proposed amendment is confined to (i) organizational and procedural matters; (ii) modifications to systems used for security; and (iii) administrative changes. The proposed amendment also addresses security organizational changes and describes procedural and other administrative changes.
Therefore, pursuant to 10 CFR 51.22(b), an environmental assessment or impact statement.is not required to be prepared in connection with the proposed amendment.
5.0 Precedent None 6.0 Conclusion Based on the considerations discussed above, (1) there is reasonable assurance that the health and safety of the public will not be endangered by the proposed changes, (2) activities consistent with the approved changes will be conducted in compliance with the Commission's regulations, and (3) the issuance of the amendment will not be inimical to the common defense and security or to the health and safety of the public.
7.0 References
- 1.
Letter from Holtec Decommissioning International, LLC to U.S. Nuclear Regulatory Commission - "Physical Security Plan Revision and License Amendment Request to Incorporate Additional Independent Spent Fuel Storage Installation," dated April 2, 2020.
(ML20136A038) to HDI-PIL-20-076 Page 5 of7
HOLTEC DECOMMISSIONING INTERNATIONAL Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909
- 2.
NRC Interim Staff Guidance NS
- empt...,*,n<
- ,,r------------i Icense Amendment Requests for Decommissioning Nuclear Power Plants," September 28, 2015 (ML15106A737)
- 3..
Letter, Entergy Nuclear. Operations,.lnc. to USNRC, "Certifications of Permanent Cessation of Power Operations and Permanent Removal of Fuel from the Reactor Vessel,"
dated June 10, 2019, (Accession No. ML 1961A033).
- 4.
NUREG-0586, "Final Generic Environmental Impact Statement on Decommissioning ci _
~Nuclear i=acilities,"~Volumes--1 & 2-of-Supplement-1,-Novembet 200Z{M[023470327ancf - -
- 5.
NRC Regulatory Guide 5.69, "Guidance for. the Application of the Radiological Sabotage Design-Basis Threat in the Design, Development, and Implementation of a Physical Security Program that Meets 10 CFR 73.55 Requirements".
8.0 Tables Table -1 PNPS Physical Security Plan (PSP), Revision 20, 10 CRF 73.55(r) Change Matrix to HDI-PIL-20-076 Page 6 of7
HOLTEC DECOMMISSIONING iNTERNATIONAl-Table 1 Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax(856)797-0909 PNPS Physical Security Plan (PSP), Revision 20, 10 CRF 73.SS(r) Change Matrix PSP Section Section Title Details Section Protection Against a Vehicle Updated verbiage to be in line with the 11.2.2 Bomb of...
current shutdown and defueled condition.
__ Section __
11.2.3
_ _ Waterbome-ThreatMeasures- -
- lJpdated verbiage to-be in line with the current shutdown and defueled condition.
Chapter 18 Figure 25.1 Appendix A Appendix B Appendix C Chapter 7 Section 7.1 Section 7.2 Appendix D Response Requirements Facility Layout Glossary of Terms and Acronyms Training and Qualification Plan PNPS Safeguards Contingency Plan Protective Strategy Defense in Depth Strategy Outer Defense - Vehicle Barrier System (VBS) and OCA Land-based Assault PNPS Independent Spent Fuel Storage Installation II (ISFSI II) to HDI-PIL-20-076 Page7 of7 Modified the committed number of Armed Responders and Armed Officers.
Updated to reflect removal of structures and addition of security barriers.
NO CHANGES NO CHANGES N/A Updated verbiage to be in line with the current shutdown and defueled condition with regards to Target Sets.
Updated verbiage to be in line with the current shutdown and defueled condition with regards to additional access/egress point through barrier system NO CHANGES*
HOLTEC Krishna P. Sing'1 Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 DECOMMISSIONING INTERNATIONAi..
.Attachment 2 to.
HDI-PIL-20"'."076 Telephone (856) 797-0900 Fax(856)797-0909 Proposed Change to PNPS Renewed Facility License Condition 3.G (mark-up) to HDI-PIL-20-076 Page 1 of2 (2 pages including cover page)
HOLT EC DECOMMISSIONING INTERNATIONAL Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 Telephone (856) 797-0900 Fax (856) 797-0909 Existing License Condition 3.G (first paragraph) (mark-up)
G.
Physical Protection The licensee shall fully implement and maintain in effect all provisions of the Commission-approved physical security, training and qualification, and safeguards contingency plans including amendments made pursuant to provisions ofthe Miscellaneous Amendments and * *
- Search Requirements revisions-to-10-CFR 73;55 (51 FR 27817 and27822), ana the aufhority-of-10 CFR 50.90 and 10 CFR 50.54(p). The combined set of plans, which contain Safeguards Information protected under 10 CFR 73.21, is entitled: "Pilgrim Nuclear Power Station Security Plan, Training and Qualification Plan, and Safeguards Contingency Plan, Revision O," submitted by letter dated October 18, 2004, as supplemented by letter dated May 16, 20 to HDI-PIL-20-076 Page2 of2 October 05, 2020
K_ris_h_n_a_P_._S_in_g_h_T_ec_h_n_ol_og_y_C_a_m_p_u_s_,_1_H_o_lre_c_B_lv_d_.,_C_a_m_d_e_n,_N_J_0_8_1_0_4 HOLTE C Telephone (856) 797-0900 DECOMMISSIONING INTERNATION,H Fax (856) 797-09()9 to HDI-PIL.. 20-076-Revised PNPS Renewed Facility Operating License Condition 3.G (clean copy) to HDI-PIL-20-076 Page 1 of2 (2 pages including cover page)
K_ris_h_n_a_P_._S_in_gh_T_ec_h_n_ol_o_gy_C_am_pu_s_,_1_H_o_lte_c_B_lv_d_.,_C_a_m_d_e_n_,N_J_08_1_0_4 HOLTE C Telephone (856) 797-0900 P~COMMl!iSIONiNG INHRNATIONAL Fax (856) 797-0909 Revised License Condition 3.G (first paragraph) (Clean Copy)
G.
Physical Protection The licensee shall fully implement and maintain in effect all provisions of the Commission-approved physical security, training and qualification, and safeguards contingency plans including amendments mad_e P!JrS_Uant to __ 10_CFR]2.212(b){9)and to-the-authority of 10CFR
-50.90-ana 10 Ci=-R 50.54(p). The combined set of plans, which contain Safeguards Information protected under 10 CFR 7321, is entitled: "Pilgrim Nuclear Power Station Security Plan, Training and Qualification Plan, Safeguards Contingency Plan, and Pilgrim ISFSI II Physical Security Plan, Revision 20;" supplemented by letter dated October 05, 2020. to HDI-PIL-20-076 Page2 of2
- SAFEGUARDS INFORMATION Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 HOLTE C ---------------------
o~coMM,ss10NiN(;
Telephone (856) 797-0900 INT~RNhTIONAL J to HDI Letter HDI-PIL-20-0 76 Description of PNPS Physical Security Plan Changes (33 pages including Cover Sheet)
Fax (856) 797-0909 NOTE: ATTACHMENTS 1,2,3 and 7 TO THI~ ENCLOSURE CON)"AIN "SAFEGUARDS INFORMATION' AND MUST BE MUST BE PROTECTED ACCORDINGLY. ATTACHMENTS 4, 5, and 6 CONTAIN SECURITY RELATED INFORMATION AND MUST BE PROTECTED ACCORDINGLY. UPON REMOVAL OF THESE ATTACHMENTS THIS ENCLOSURE BECOMES DECONTROLLED. to HDI~PIL-20-076 P~ge 1 of33
- sAFEGUARDS INFORMATION
SAFEGUARDS INFORMATION Krishna P. Singh Technology Campus, 1 Holtec Blvd., Camden, NJ 08104 HOLTE C ------------'------C...----------
oecoMM1ss10N1Nc; Telephone (856) 797-0900 INT~RNATIONA~
Fax (856) 797-0909 Description Page No.
Purpose of Requested License Amendment................................................................ 3 Executive Summary................................................................................................................. 5 Description and Evaluation of Proposed Changes.............................................. :....... ~........... 8 1.0 Summary Description
-- 2;0-Detailed*DescriptiO"n and-Basis for fhe-Cha-nges 2.1 Proposed Changes to the Pilgrim Physical Security Plan 2.2 Programmatic Assumptions Used for Alternative Measure
- 1. Defense in Depth
- a. Design Basis Threat
- b. Target Set(s)
- c. Defensive Strategy
- 2. Evaluation Date
- 3. Training
- 4. Equipment
- 5. Modifications Design and Implementation 2.3 Alternative Measures Proposed for the Pilgrim Physical Security Plan 2.4 Summary Evaluation of Proposed Alternative Measures 2.5 Applicable Orders for Pilgrim Nuclear power Station 2.6 Actions To Be Completed Prior to Implementation of Revision 20 3.0 References Attachments to Enclosure 1................................................................................ 33 : Target Set(s) (SGI} : Blast Calculations (SGI} : Pilgrim 360 - Defensive Strategy Evaluation and Data (SGI} : Lesson Plan and Training Needs Analysis (SRI) : 10 CFR 73.55 - Compliance Matrix (SRI} : 10 CFR 73 Appendix C - Compliance Matrix (SRI) : NRC Order EA-13-132, Compliance Matrix (SGI)
NOTE: ATTACHMENTS 1,2,3 and 7 TO THIS ENCLOSURE CONTAIN "SAFEGUARDS INFORMATION' AND MUST BE MUST BE PROTECTED ACCORDINGLY. ATTACHMENTS 4, 5, and 6 CONTAIN SECURITY RELATED INFORMATION AND MUST BE PROTECTED ACCORDINGLY. UPON REMOVAL OF THESE ATTACHMENTS THIS ENCLOSURE BECOMES UNCONTROLLED. to HDI-PIL-20-076 Page2 of33 SAFEGUARDS INFORMATION