Text
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-1 of 2-123 Revision 0, 2020 CHAPTER 2 SITE AND ENVIRONMENT 2.1 Summary and Conclusions This section of the DSAR sets forth the site and environmental data, which together formed the basis for the criteria for designing the facility and for evaluating the routine and accidental release of radioactive liquids and gases to the environment. These data support the conclusion that there will be no undue risk to public health and safety with the facility as designed and the environmental characteristics as described. This conclusion rests not only upon the data, but upon the scientific documentation of several independent consultants in their particular area of expertise-health physics, demography, geology, seismology, hydrology, and meteorology.
Environmental characteristics of the area have been documented by field measurements and studies conducted since 1958. These studies quantified the effects on the environment of the operation of nuclear power plants.
Conservative projections have been made of the probable growth of population in the area, and these projections have been taken into account in facility design both as to control of accidents and as to assumptions about operation.
[Historical Information] According to 1980 population estimates, about 50 people reside within a 1100-m radius of Unit 2 (most of them to the east-southeast), and approximately 2600 live within 1-mile. Approximately 75,000 people reside within a 5-mile radius of the facility. The largest concentration of population is in the City of Peekskill, the center of which is about 2.5-miles northeast of the site. The most densely populated 15-degree sector, within 5-miles, is toward Peekskill to the northeast.
The 1960 population within a 15-mile radius of the site was approximately 352,000, whereas in the year 2000 the estimated population is 1,107,195. The projections do not indicate, and there is no reason to conclude otherwise, that the land usage within this radius will shift appreciably during the intervening period. (The land is now zoned principally for residential and state park use, although there is some industrial activity and minor or isolated agricultural and grazing activity.)
The outer boundary of the low-population zone has been set at 1100 m from Unit 2.
Geologically, the site consists of a hard limestone in a jointed condition that provides a solid bed for the facility foundation. The bedrock is sufficiently sound to support any loads that could be expected up to 50 tons/ft2, which is far in excess of any load that may be imposed by the facility.
Although it is hard, the jointed limestone formation is permeable to water. Thus, if water from the facility should enter the ground, it would percolate to the river rather than enter any ground-water supply.
About 80 million gallons of Hudson River water flow past the facility each minute during the peak tidal flow. This flow will provide additional mixing and dilution for liquid discharges from the facility.
The assumption in the facility design is to treat the river water as if it were used for drinking and thus to reduce radioactive discharge, by dilution with ordinary plant effluent, to concentrations that would be tolerable for drinking water. There is a very low probability of flooding at the site.
[Historical Information] Seismic activity in the Indian Point area is limited to low-level microseismicity. Detailed field investigations1-3 have been conducted in the immediate vicinity of
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-2 of 2-123 Revision 0, 2020 Indian Point and along the major faults in the region. To date, no evidence has been found in the rocks exposed at the surface or sediment overlying fault traces or in cores obtained in the vicinity of Indian Point that might support a conclusion that displacement has occurred along major fault systems within the New York Highlands, the Ramapo, or its associated branches during Quaternary time (the last 1.5 million years). In the vicinity of Indian Point, evidence that no displacement has occurred in the last 65 million years (since the Mesozoic) along specific major structures has been observed.
The facility is designed to withstand an earthquake of Modified Mercalli Intensity VII as required by Appendix A to 10 CFR 100 "Seismic and Geologic Siting Criteria for Nuclear Power Plants." The validity of the selection of an Intensity VII earthquake was adjudicated before the Atomic Safety Licensing Appeal Board. The Appeal Board's decision (ALAB-436) verified Intensity VII as the facility's design-basis earthquake.
Meteorological conditions in the area of the site were determined during a 2-year program (1955 to 1957). The validity of these conclusions has been verified by several programs, including that performed by the Atmospheric Services Department of York Services Corporation in completing a meteorological update for Consolidated Edison Company in 1981 (see Appendix 2A).
[Historical Information] These data have been used in evaluating the effects of gaseous discharges from the facility during normal operations and during the postulated accidents (as previously bounded by the historical hypothetical loss-of-coolant accident). The evaluations indicate that the site meteorology provides adequate diffusion and dilution of any released gases.
Environmental radioactivity has been measured at the site and surrounding area since 1958 in association with the operation of Indian Point Unit 1 and the construction and operation of Indian Point Units 2 and 3. Unit 3 is owned by Entergy Nuclear Indian Point 3, LLC. These measurements will be continued and reported. The radiation measurements of fallout, water samples, vegetation, marine life, etc., have shown no perceptible post-operative increase in activity. Noticeable increases in fallout have coincided with weapons-testing programs and appear to be related almost entirely to those programs. The New York State Department of Health in an independent 2-year postoperative survey4,5 found that environmental radioactivity in the vicinity of the site is no higher than anywhere else in the State of New York.
[Historical Information] Consultants who have participated in the preparation of the various reports, measurements, and conclusions appearing in this chapter include Dr. Merril Eisenbud, director of Environmental Radiation Laboratory, Institute of Industrial Medicine, New York University; Dr. Benjamin Davidson (deceased), meteorologist and director, Geophysical Science Laboratory, New York University College of Engineering; Dr. James Halitsky, senior research scientist, Department of Meteorology and Oceanography, New York University, College of Engineering; Dr. Edgar M. Hoover, Regional Economic Development Institute, Inc.; Metcalf and Eddy Engineers, hydrology specialists; Quirk, Lawler, and Matusky Engineers, Environmental Science and Engineering Consultants; Mr. Karl R. Kennison, consulting civil and hydraulic engineer; and Woodward-Clyde Consultants, consulting engineers, geologists and environmental scientists.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-3 of 2-123 Revision 0, 2020 REFERENCES FOR SECTION 2.1
- 1.
Ratcliffe 1976.
- 2.
Ratcliffe 1980.
- 3.
Dames & Moore 1977.
- 4.
Hollis S. Ingraham, Consolidated Edison Indian Point Reactor Environmental and Post Operational Survey - August, 1965, Division of Environmental Health Services, New York State Department of Health.
- 5.
Hollis S. Ingraham, Consolidated Edison Indian Point Reactor Environmental and Post Operational Survey - July, 1966, Division of Environmental Health Services, New York State Department of Health.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-4 of 2-123 Revision 0, 2020 2.2 Location 2.2.1 General
[Historical Information] Indian Point is a multiunit site consisting of approximately 239 acres of land on the east bank of the Hudson River at Indian Point, village of Buchanan, in upper Westchester County, New York. Indian Point Units 2 and 3 (see Section 2.2.3) are located north and south, respectively, of Unit 1, which has been retired. The site is about 24-miles north of the New York City boundary line. The nearest city is Peekskill, located 2.5-miles northeast of Indian Point, with a population of about 20,000. An aerial photograph, Historical Figure 2.2-1, shows the site and about 58-miles2 of the surrounding area.
2.2.2 Access The site is accessible by several roads in the village of Buchanan. A paved road links the eastern boundary of the site to the existing facility. The existing wharf is used to receive heavy equipment as needed. The site is not served by rail.
2.2.3 Site Ownership And Control Entergy owns the Indian Point Units 1 and 2 Nuclear Power Plants. As shown in Figure 2.2-3, the Algonquin Gas Transmission Company has a 26-inch gas mainline and a 30-inch gas mainline on a 65-foot wide right-of-way running east to west through the property. Unit 2 is 1450-ft north of the 26-in. Algonquin gas mainline. One 30-inch main and 2-24-inch mains pass under the river to a pipeline facilities station on the easement near the river. One 24-inch main is available as a bypass alternative and ends in the pipeline facilities station while the other two continue as the 30-inch and 26-inch mains.
The Algonquin Gas Transmission Company has installed a 42-inch gas mainline that crosses the Hudson River south of the site property and turns north. It passes through the south-easternmost corner of the site and then crosses Broadway between the Buchanan Switchyard and the GT 2/3 fuel oil storage tank. The 42-inch main joins the 30-inch and 26-inch mains north of the switchyard and east of the site. Potential hazards posed by the mainlines on IPEC structures and equipment have been evaluated.
The Georgia-Pacific Corporation has an easement, 1610-ft long and 30-ft wide, through the southerly part of the Indian Point site. The Georgia-Pacific easement is used for overhead electrical power and telephone lines and underground gas, water, and sewer lines. These easements permit Entergy to determine all activities within the right-of-way in order to ensure safe operation of the units.
Units 1, 2, and 3 have a security fence surrounding the "protected" areas. Access to the protected areas is controlled via security buildings that are manned on a 24-hr basis. In addition, spaces within the protected area designated as "vital areas" are provided with additional access control.
All roads within the site are continuously patrolled by security personnel. A site plot plan is shown in Plant Drawing 504688 (Formerly Figure 2.2-2).
2.2.4 Activities On The Site The principal activities on the site are the generation, transmission, and distribution of electrical energy; associated service activities; activities relating to the controlled conversion of the nuclear
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-5 of 2-123 Revision 0, 2020 energy of fuel to heat energy by the process of nuclear fission; and the storage, use, and production of special nuclear source and byproduct materials.
2.2 FIGURES Figure No.
Title Figure 2.2-1 Aerial Photo of Indian Point Site and Surrounding Area
[Historical]
Figure 2.2-2 Indian Point Building Identification Replaced with Plant Dwg No.
504688 Figure 2.2-3 Algonquin Gas Transmission Pipeline Hudson River Crossing &
Indian Point Nuclear Generation Facility
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-6 of 2-123 Revision 0, 2020 2.3 Topography
[Historical Information] The Indian Point Generating Station is on the east bank of the Hudson River. The river runs northeast to southwest at this point but turns sharply northwest approximately 2-miles northeast of the facility. The west bank of the Hudson is flanked by the steep, heavily-wooded slopes of the Dunderberg and West Mountains to the northwest (elevations 1086 and 1257-ft, respectively, above mean sea level) and Buckberg Mountain to the west-southwest (elevation 793-ft). These peaks extend to the west and gradually rise to slightly higher peaks.
The general orientation of this high ground is northeast to southwest. One-mile northwest of the site, Dunderberg bulges to the east. North of Dunderberg and the site, high grounds reaching 800-ft form the east bank of the Hudson River. At this location the Hudson River makes a sharp turn to the northwest. To the east of the site, peaks are generally lower than those to the north and west. Spitzenberg and Blue Mountains average about 600-ft in height, and there is a weak, poorly-defined series of ridges that run in a north-northeast direction. To the west of the site there are the Timp Mountains at an elevation of 846-ft. To the south of the site, elevations of 100-ft or less gradually slope towards Verplanck. The river south of the site makes another sharp bend to the southeast and then widens as it flows past Croton and Haverstraw.
Historical Figure 2.3-1 shows topographic features of the site and the surrounding areas.
2.3 FIGURES Figure No.
Title Figure 2.3-1 Topographical Map of Indian Point and Surrounding Area [Historical]
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-7 of 2-123 Revision 0, 2020 2.4 Population and Land Use 2.4.1 Overview The population within a 50-mile radius of the Indian Point site has been estimated for 1990.
These population estimates were taken from statistics recently released by the U.S. Census Bureau. The population within the 50-mile radius of Indian Point has increased from the 1980 estimates by approximately 68,000 people, less than half of one percent.
2.4.2 Population And Land Use According to 1990 estimates, approximately 15.465 million people live within a 50-mile radius of the Indian Point site. A major part of this number live in New York City, an area 25 to 50-miles south of the facility. Approximately 1650 persons, concentrated in sectors south to southeast of the station, live within 1-mile of the facility. Approximately 74,000 persons live within 5-miles of the facility.
The area surrounding the Indian Point site is generally residential with some large parks and military reservations. Some increased commercial development has occurred within a mile of the station since 1980. Most of the area to the east of the Hudson River within 15-miles of the site is zoned for residential uses. West of the Hudson within a 15-mile radius, the Palisades Interstate Park and residential areas are the dominant land uses. The only agricultural areas within 15-miles are south or northwest of the facility on the west side of the River.
Several maps and tables are included to illustrate the population distribution and land use of the area. Figure 2.4-1 and Figure 2.4-2 show the sector/zone approach to the population data and the area within a 50-mile radius of the Indian Point site. Historical Figures 2.4-3 through Figure 2.4-5 illustrate the 1980 population distribution radically by sectors out to 50-miles from the facility site. Historical Figure 2.4-6 through Figure 2.4-8 show, respectively, the land uses based on official zoning maps, areas served by public utilities, and areas served by sewage systems, all as of 1970. Table 2.4-1 explains the sector/zone designations for the population maps and tables that follow. [Historical] Table 2.4-2 through Table 2.4-18 give the 1990 estimated populations for all sector/zones within a 50-mile radius of the Indian Point site.
The New York State Department of Commerce projects no substantial increases in population from 1986 to the year 2013 in any of the four counties in the vicinity of Indian Point.
[Historical] Table 2.4-19 and Table 2.4-20 show the estimated and projected land uses by County for 1960 and 1980, respectively. These estimates were developed by the Regional Economic Development Institute, Inc., from Regional Planning Association data.
2.4.3 Low-Population Zone About 50 people reside within a 1100-m radius of Unit 2, most of them to the east-southeast.
This distance was used as the outer boundary of the low population zone in the analysis of a postulated fission product release. The water boundary (Peekskill Bay) of the more densely populated area of Peekskill was used as the population center distance, which exceeds 1-1/3 times the distance from the reactor to the outer boundary of the low-population zone. A low-population zone outer boundary radius of 1100-m satisfies both 10 CFR 100.11(a)(3) and 10 CFR 50.67. The low-population zone population in the year 2010 is projected to be approximately 88.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-8 of 2-123 Revision 0, 2020 2.4.4 Exclusion Area The exclusion area for Indian Point Unit 2 includes facility property within a 520-m radius of the reactor containment. An exclusion radius of 520-m satisfies both 10 CFR 100.3(a) and 10 CFR 50.67.
2.4.5 Population Data Sources The population data used in this section were developed from the following sources:
- 1.
1978 Official Population Projections for New York State Counties, prepared by the Economic Development Board, New York State Department of Commerce.
- 2.
Population by Municipality 1970-2000, prepared by the Westchester County Department of Planning, October 1979.
- 3.
Population of Rockland County, Capacity and Forecast, 1970-2000, prepared by the Rockland Planning Board, April 1978.
- 4.
Population Estimate and Projections, Orange County, New York, prepared by the Orange County Planning Department, March 1980.
- 5.
Putnam County Population Projections, prepared by the Putnam County Planning Board, 1977.
- 6.
New Jersey Revised Total and Interim Age and Sex Population Projections, 1980-2000, prepared by the New Jersey Department of Labor and Industry, Division of Planning and Research, Office of Demographic and Economic Analysis, April 1979.
- 7.
State of Connecticut Population Projections for Connecticut Municipalities and Regions to the Year 2000, prepared by the Office of Policy and Management, Comprehensive Planning Division, February 1980.
- 8.
Pennsylvania Projection Series, Summary Report, Employment by Labor Market Area, and Population and Labor Force by County for 1980, 1985, 1990, 1995 and 2000, Report No. 78, PPS-1, prepared by the Office of State Planning and Development, State Economic and Social Research Data Center, June 1978.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-9 of 2-123 Revision 0, 2020 TABLE 2.4-1 Sector and Zone Designators for Population Distribution Map1 Sector Nomenclature Zone Nomenclature Centerline of Sector in Degrees True North from Facility 22.5° Sector2 Miles from Facility Zone 0 and 360 A
0-1 1
22.5 B
1-2 2
45 C
2-3 3
67.5 D
3-4 4
90 E
4-5 5
112.5 F
5-6 6
135 G
6-7 7
157.5 H
7-8 8
180 J
8-9 9
202.5 K
9-10 10 225 L
10-15 15 247.5 M
15-20 20 270 N
20-25 25 292.5 P
25-30 30 315 Q
30-35 35 337.5 R
35-40 40 Notes:
- 1.
An area is identified by a sector and zone alphanumeric designator (refer to Figure 2.4-1). Thus, area A1 is that area, which lies between 348.75-and 11.25-degrees true north from the facility out to a radius of 1-mile. Area G4 would be that area between 123.75-to 146.25-degrees and the 3-and 4-mile arcs from the facility.
- 2.
The letters I and 0 have been omitted from sector designators so as to eliminate possible confusion between letters and numbers.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-10 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-2 Population Estimates, 1990, For All Sectors Zone Population 1
1,644 2
15,130 3
18,428 4
14,225 5
24,508 6
25,922 7
28,096 8
25,967 9
36,930 10 46,488 15 342,852 20 488,652 25 920,850 30 2,171,399 35 2,276,172 40 3,451,123 45 3,416,140 50 2,199,601
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-11 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-3 Population Estimates, 1990, for Sector A (North)
Sector, Zone Population A1 0
A2 70 A3 0
A4 0
A5 400 A6 390 A7 5,301 A8 5,898 A9 2,474 A10 874 A15 4,132 A20 36,987 A25 31,000 A30 57,873 A35 39,998 A40 20,100 A45 17,689 A50 40,853
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-12 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-4 Population Estimates, 1990, for Sector B (North-Northeast)
Sector, Zone Population B1 0
B2 54 B3 139 B4 143 B5 1,721 B6 1,553 B7 867 B8 246 B9 2,123 B10 1,187 B15 4,343 B20 7,982 B25 20,310 B30 16,651 B35 4,800 B40 6,991 B45 8,457 B50 5,761
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-13 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-5 Population Estimates, 1990, for Sector C (Northeast)
Sector, Zone Population C1 0
C2 4,879 C3 9,102 C4 4,159 C5 5,534 C6 3,895 C7 2,382 C8 1,594 C9 630 C10 1,034 C15 10,371 C20 9,685 C25 8,200 C30 12,479 C35 13,687 C40 13,067 C45 7,901 C50 6,621
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-14 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-6 Population Estimates, 1990, for Sector D (East-Northeast)
Sector, Zone Population D1 49 D2 2,379 D3 2,691 D4 1,899 D5 2,324 D6 2,272 D7 4,667 D8 4,713 D9 5,982 D10 3,900 D15 32,854 D20 14,721 D25 8,961 D30 82,240 D35 21,876 D40 18,762 D45 12,991 D50 60,032
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-15 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-7 Population Estimates, 1990, for Sector E (East)
Sector, Zone Population E1 59 E2 560 E3 0
E4 289 E5 279 E6 345 E7 1,769 E8 1,138 E9 3,287 E10 3,762 E15 17,702 E20 5,099 E25 22,465 E30 20,987 E35 15,730 E40 159,720 E45 162,993 E50 101,121
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-16 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-8 Population Estimates, 1990, for Sector F (East-Southeast)
Sector, Zone Population F1 147 F2 305 F3 336 F4 689 F5 260 F6 987 F7 475 F8 860 F9 758 F10 1,999 F15 19,121 F20 11,728 F25 49,821 F30 120,701 F35 58,734 F40 33,691 F45 0
F50 29,199
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-17 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-9 Population Estimates, 1990, for Sector G (Southeast)
Sector, Zone Population G1 575 G2 2,298 G3 1,295 G4 769 G5 420 G6 3,702 G7 3,892 G8 2,672 G9 2,159 G10 6,890 G15 27,939 G20 23,849 G25 86,999 G30 44,001 G35 17,093 G40 79,903 G45 240,102 G50 328,012
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-18 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-10 Population Estimates, 1990, for Sector H (South-Southeast)
Sector, Zone Population H1 109 H2 1,782 H3 1,363 H4 741 H5 93 H6 0
H7 0
H8 78 H9 5,039 H10 5,752 H15 22,162 H20 103,969 H25 226,002 H30 252,482 H35 209,921 H40 535,969 H45 723,004 H50 469,960
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-19 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-11 Population Estimates, 1990, for Sector J (South)
Sector, Zone Population J1 531 J2 650 J3 20 J4 129 J5 1,351 J6 4,012 J7 3,133 J8 4,308 J9 5,189 J10 4,321 J15 40,993 J20 55,102 J25 220,032 J30 954,691 J35 1,472,384 J40 1,907,927 J45 1,601,010 J50 702,739
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-20 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-12 Population Estimates, 1990, for Sector K (South-Southwest)
Sector, Zone Population K1 174 K2 1,245 K3 1,282 K4 2,049 K5 8,093 K6 4,124 K7 2,526 K8 2,531 K9 6,291 K10 9,371 K15 86,297 K20 72,902 K25 146,895 K30 427,391 K35 321,209 K40 534,296 K45 444,572 K50 353,770
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-21 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-13 Population Estimates, 1990, for Sector L (Southwest)
Sector, Zone Population L1 0
L2 63 L3 1,621 L4 2,694 L5 2,184 L6 4,059 L7 2,876 L8 902 L9 2,087 L10 4,021 L15 26,019 L20 28,753 L25 41,514 L30 94,167 L35 31,725 L40 89,824 L45 124,188 L50 54,722
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-22 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-14 Population Estimates, 1990, for Sector M (West-Southwest)
Sector, Zone Population M1 0
M2 359 M3 188 M4 399 M5 169 M6 274 M7 170 M8 15 M9 96 M10 271 M15 5,139 M20 4,976 M25 14,343 M30 8,817 M35 21,625 M40 18,889 M45 47,849 M50 30,319
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-23 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-15 Population Estimates, 1990, for Sector N (West)
Sector, Zone Population N1 0
N2 292 N3 214 N4 0
N5 0
N6 0
N7 0
N8 23 N9 438 N10 63 N15 3,321 N20 8,827 N25 10,234 N30 7,794 N35 14,233 N40 9,028 N45 9,007 N50 2,109
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-24 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-16 Population Estimates, 1990, for Sector P (West-Northwest)
Sector, Zone Population P1 0
P2 85 P3 52 P4 0
P5 32 P6 58 P7 9
P8 626 P9 357 P10 2,004 P15 17,997 P20 9,983 P25 12,394 P30 47,277 P35 5,927 P40 9,121 P45 3,960 P50 3,917
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-25 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-17 Population Estimates, 1990, for Sector Q (Northwest)
Sector, Zone Population Q1 0
Q2 0
Q3 125 Q4 189 Q5 55 Q6 0
Q7 29 Q8 321 Q9 0
Q10 1,039 Q15 7,023 Q20 9,872 Q25 10,745 Q30 12,244 Q35 10,160 Q40 7,942 Q45 5,653 Q50 6,962
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-26 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-18 Population Estimates, 1990, for Sector R (North-Northwest)
Sector, Zone Population R1 0
R2 109 R3 0
R4 76 R5 1,593 R6 251 R7 0
R8 42 R9 20 R10 0
R15 17,439 R20 44,219 R25 10,935 R30 12,144 R35 17,070 R40 5,893 R45 6,764 R50 3,504
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-27 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-19 Estimated Land Use in 1960 and Projected Land Use in 19801 Within a 55-Mile Radius Intensive 1960 and 1980 Nonintensive 1960 Nonintensive 1980 1
2 3
4 5
6 7
8 9
10 11 12 Public Community Public Industrial/
Institutional Rights-Facilities Parks Rights-Grand Residential Commercial Total and Park of-Way Total Institutions Recreation of-Way Total Open Totals 1960 Square miles 1032 216 1248 696 418 1114 4062 6424 Percentage of total developed land 43 9
52 29 19 48 High 58 12 45 22 Low 32 2
15 15 1980 Square miles 2040 368 2408 876 784 682 2342 1674 6424 Percentage of total developed land 43 8
51 19 16 14 49 1960-1980 Square miles of land to be developed 1400 220 1620 1228 Percentage of total land to be developed 58 42 Notes:
- 1.
The averages were derived from the data in Table 3. The Use of Developed Land in Selected Areas of the Regions. RPA Bulletin Number 100, Page 21, September 1962. The data for square miles excludes Monmouth County from the original Regional Plan Association (RPA) totals.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-28 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-20 (Sheet 1 of 2)
Land Use Projection by County for 1980 in Square Miles Within a 55-Mile Radius Counties in Con Ed Study Area Intensive Low Intensive Community Outside Industrial/
Facilities Parks Public Rights-State In RPA Region RPA Region Residential Commercial Community Institutions Recreation Of Way Open Conn.
Fairfield 183 33 92 83 71 171 Litchfield
[30]1
[6]
[3]
[3]
[2]
[5]
New Haven
[88]
[19]
[73]
[65]
[55]
[134]
N.J.
Bergen 118 22 20 19 16 38 Essex 83 16 6
6 5
12 Hudson 26 5
3 3
2 6
Middlesex 126 (58)2 22 (10) 18 16 14 34 Morris 130 23 69 63 54 129 Passaic 75 14 23 21 18 43 Somerset 71 (24) 13 (4) 16 15 12 30 Sussex
[34]
[8]
[107]
[97]
[83]
[199]
Union 63 12 6
6 5
11 Warren
[3]
[1]
[9]
[9]
[7]
[18]
N.Y.
Dutchess 106 19 152 138 117 283 Nassau 230 41 5
4 4
9 Orange 110 20 154 140 119 286 Putnam 37 6
42 38 32 79 Rockland 56 10 25 23 19 46
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-29 of 2-123 Revision 0, 2020
[Historical] TABLE 2.4-20 (Sheet 2 of 2)
Land Use Projection by County for 1980 in Square Miles Within a 55-Mile Radius Counties in Con Ed Study Area Intensive Low Intensive Community Outside Industrial/
Commercial Facilities Community Parks Recreation Public Rights-Of Way Open State In RPA Region RPA Region Residential N.Y.
Suffolk 279 (199)2 50 (35) 92 84 72 172 Sullivan
[8]1
[4]
[117]
[106]
[90]
[217]
Ulster
[53]
[12]
[207]
[188]
[160]
[386]
Westchester 162 31 53 48 42 99 Bronx 25 4
3 3
2 5
Kings 42 7
4 4
4 8
New York 14 2
1 1
1 3
Queens 65 11 7
7 6
13 Richmond 39 7
3 2
2 5
P.A.
Pike
[7]
[1]
[76]
[69]
[59]
142 Total RPA Region3 2040 368 7943*
7243*
6173*
14823*
Total Consolidated Edison Area 2078 383 1385 1261 1073 2583 Notes:
- 1.
Figures in brackets are for those counties outside RPAs Region. They are added to the total for Con Eds area.
- 2.
Figures in parentheses are those portions of the RPA Region contained in the Con Ed area.
- 3.
Total RPA Region figures followed by
- indicate that only the portion of the counties in Con Eds area are included.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-30 of 2-123 Revision 0, 2020 2.4 FIGURES Figure No.
Title Figure 2.4-1 Schematic Sector/Zone Diagram Figure 2.4-2 Indian Point Station Ten and Fifty Mile Radius Map Figure 2.4-3 Five Mile Sector/Zone Diagram [Historical]
Figure 2.4-4 Ten Mile Sector/Zone Diagram [Historical]
Figure 2.4-5 Fifty Mile Sector/Zone Diagram [Historical]
Figure 2.4-6 Map and Description Showing Land Usage [Historical]
Figure 2.4-7 Map and Description of the Area Showing Public Utilities
[Historical]
Figure 2.4-8 Map and Description of the Area Showing Sewage Systems
[Historical]
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-31 of 2-123 Revision 0, 2020 2.5 Hydrology The hydrologic features of the Indian Point site are relevant to the analysis of radioactive liquid discharges from the facility. These features are the Hudson River, ground water and wells, and surface-water reservoirs. During the conduct of normal activities, liquid wastes are discharged to the Hudson River through the circulating water discharge canal. Ground-water contamination from accidental ground seepage or leakage from the facility will flow to the river because of the higher elevation of the facility relative to the river.
Between 2005 and 2007, GZA GeoEnvironmental (GZA), performed a comprehensive hydrogeologic investigation of the site. This investigation was initiated to understand groundwater flow and contaminant transport. During this investigation numerous borings were advanced to study the site geology, hydrology and aquifer properties. Details of the geology, hydrology and aquifer properties can be found in the GZA report5.
The hydrology in the environs of the Indian Point site has been extensively studied for Con Edison by numerous consultants, augmenting the data base established through the investigations of various governmental agencies. The initial Con Edison study was conducted in 1955 by Kennison,1 who analyzed the flow characteristics of the river at the site. Metcalf and Eddy2 further examined the river flow, and also investigated local groundwater hydrology and surface-water reservoirs. The salient aspects of these and other studies3,4 are reported below.
The Hudson River below the dam at Troy (immediately below the confluence of the Hudson and Mohawk Rivers) is a tide-influenced, estuarine waterway. (see Figure 2.5-1.) Fresh water from the combined Hudson and Mohawk Rivers, as well as from numerous tributaries, discharges directly into the tidal portion of the river. Seawater enters the extreme lower reaches of the river through the Narrows and the Harlem/East River. The distribution of saltwater is influenced by fresh water flow, tides, physical characteristics of the river channel, and weather.
Flow in the Hudson River is controlled more by the tides than by the runoff from the tributary watershed. River width opposite the facility ranges from 4500 to 5000-ft. Water depths within 1000-ft of the shore near the site are variable with an average depth of 65-ft; at some points the depth exceeds 85-ft. River cross-sectional areas in the vicinity of the site range from 165,000 to 170,000-ft2. Tidal flow past the facility is about 80 million gpm about 80-percent of the time, and it has been estimated that this frequency flow is at least 9 million gpm in a section 500-600-ft wide immediately in front of the facility. Mean tidal flow in the vicinity of the site is over 70 million gpm.
The average downstream flow (for a 17-year period preceding 1930) is in excess of:2 11,700,000 gpm 20-percent of the time.
6,800,000 gpm 40-percent of the time.
4,710,000 gpm 60-percent of the time.
3,100,000 gpm 80-percent of the time.
1,800,000 gpm 98-percent of the time.
The facility is designed to use the dilution characteristics of the large tidal flow and releases will be managed such that discharges into the river would not contravene regulatory limitations.
Historical flow patterns were further examined by Quirk, Lawler, and Matusky3,4 who reported both long-term (monthly) river discharges and potential drought flows. Quirk, Lawler, and Matusky also
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-32 of 2-123 Revision 0, 2020 analyzed and reported on the hydraulic conveyance properties of the estuary and the effects of tide and salinity on movement in the estuary.
Review of historical records indicates that flooding at the site is non-existent. Flood stages are primarily the effect of tidal influence, with the secondary influence of runoff. The highest recorded water elevation in the vicinity of the site was 7.4-ft above mean sea level (MSL), which occurred during an exceptionally severe hurricane in November 1950. Subsequent to that occurrence, the highest water elevation recorded at the site was 9-ft 8-in. above MSL, which occurred during the extra-tropical Superstorm Sandy in November 2012. Since the river water elevation would have to reach 15-ft 3-in. above MSL before it would seep into any of the Indian Point buildings, the potential for any flooding damage at the site appears to be extremely remote.
Seven different flooding conditions governing the maximum water elevation at the site were investigated, including the following:
- 1.
Flooding resulting from runoff generated by a probable maximum precipitation over the entire Hudson River drainage basin upstream of the site.
- 2.
Flooding caused by the occurrence of any upstream dam failure concurrent with heavy runoff generated by a standard project flood.
- 3.
Flooding due to the occurrence of a probable maximum hurricane concurrent with a spring high tide in the Hudson River.
The severest flooding condition revealed by the study results from the simultaneous occurrence of a standard project flood, a failure of the Ashokan Dam and a storm surge in New York Harbor at the mouth of the Hudson River resulting from a standard project hurricane. The water level under these conditions would reach 14-ft above MSL. Local wave action due to wind effects has been determined to add 1-ft to the river elevation producing a maximum water elevation of 15-ft above MSL at the Indian Point Site. Since this maximum water elevation is 3-in. lower than the critical elevation of 15-ft 3-in. noted earlier, it is reasonable to conclude that flooding in the Hudson River will not present a hazard to the safe operation of Indian Point.
The three most severe hurricanes to hit New York Harbor (September 21, 1821; November 25, 1950 (mentioned previously); and September 12, 1960) produced tidal surges at the Battery of 11-ft, 8.2-ft and 6.3-ft, respectively. Accordingly, these surges would appear as 7.5-ft, 5.5-ft, and 4.3-ft surges at Indian Point. The 5.5-ft surge predicted for the November 25, 1950, hurricane agrees well with the actual surge that produced the 7.4-ft-high watermark recorded for Indian Point on that date.
The Quirk, Lawler and Matusky report indicated that the combination of the maximum probable runoff, upstream dam failures and maximum ebb tide in the Hudson River is a less severe condition than the one postulated above. This latter scenario would cause the water level at Indian Point to be 11.7-ft above MSL, also below the critical control elevation.
The report also indicates that the combination of probable maximum hurricane, spring high tide, and wave run-up will cause the water level at Indian Point to reach 14.5-ft above MSL. This is also below the critical control elevation of 15-ft-3-in. Table 2.5-1 summarizes the Indian Point water surface elevations resulting from the various combinations.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-33 of 2-123 Revision 0, 2020 In view of the recorded hydrologic history of the Hudson River and New York Harbor and the predicated maximum hurricane surge at Indian Point, flooding at the site is a highly unlikely possibility.
Within a 5-mile radius of the facility only one municipal water supply uses ground water. Other wells in this area are used for industrial and commercial purposes. The rock formations in the area and elevations of wells relative to the facility are such that accidental ground leakage or seepage percolating into the ground at Indian Point will not reach these sources of ground water, but will flow to the river.
Only two reservoirs within a 5-mile radius are used for municipal water supplies. The first, Camp Field Reservoir, is the raw-water receiving basin for the system, which serves the city of Peekskill. This system uses the Catskill Aqueduct and Montrose Water District as alternative sources of water supply. The second reservoir, the impounding reservoir for the Stony Point water system, serves the towns of Stony Point and Haverstraw, and the villages of Haverstraw and West Haverstraw. The Stony Point system is connected to the Spring Valley Water Company to provide an alternative source of supply. A third reservoir within 5-miles of the facility, Queensboro Lake, supplies water to a state park area only. The location of these reservoirs, and others within a 15-mile radius of the site, are shown on Figure 2.5-2. The city of New York's Chelsea Pumping Station is located about 1-mile north of Chelsea, New York, on the east bank of the Hudson River, about 22-miles upstream of the site. Water will be pumped from intakes in the river at the rate of up to 100 million gal per day into the city reservoir system as required to supplement the primary supply from watersheds during severe drought conditions. This source, however, was not used during the recent 1981 drought.
The discharge of any contaminant into a tidal estuary will result in its distribution throughout the estuary. Factors affecting this distribution include tide amplitude and current, river geometry, salinity distribution, and freshwater discharge. Quirk, Lawler, and Matusky investigated for Con Edison the influence of these factors and determined the effect of radioactive discharges on overall river concentrations, and specifically conditions at Chelsea Pumping station, as discussed in Section 4.1. During the conduct of normal activities, the facility discharge will not exceed its maximum permissible concentration. Compliance with regulatory release limits is further discussed in Section 4.1.
REFERENCES FOR SECTION 2.5
- 1.
Letter report of Karl L. Kennison, Civil and Hydraulic Engineer, to G. R. Milne, Con Edison, November 28, 1955.
- 2.
Metcalf and Eddy Engineers, Hydrology of Indian Point Site and Surrounding Area, October 1965.
- 3.
Quirk, Lawler, and Matusky Engineers, Transport of Contaminants in the Hudson River above Indian Point Station, May 1966.
- 4.
Quirk, Lawler, and Matusky Engineers, Evaluation of Flooding Conditions at Indian Point Nuclear Generating Unit No. 3, April 1970.
- 5.
GZA, Hydrogeologic Site Investigation Report for the Indian Point Energy Center, January 7, 2008.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-34 of 2-123 Revision 0, 2020 TABLE 2.5-1 Water Surface Elevation at Indian Point Resulting from Stated Flow and Elevation Conditions Component Flow at Indian Point Elevation at the Battery -
Datum MSL (ft)
Flow at Indian Point (million cfs)
Elevation at Indian Point -
Datum-MSL (ft)
Elevation at Indian Point Including Local Oscillatory Wave Height Datum MSL (ft)
- 1. Probable maximum flood MSL 0.00 1.100 12.7 13.7
- 2. Probable Maximum flood and tidal flow High water
+/-2.20 1.014 12.4 13.4
- 3. Probable Maximum flood and tidal flow Low water 2.20 1.165 13.0 14.0
- 4. Standard project flood and Ashokan Dam failure MSL 0.00 0.705 7.2 8.2
- 5. Standard project flood Standard project hurricane
+11.00 0.550 13.0 14.0
- 6. Standard project flood and Ashokan Dam failure Standard project hurricane
(+11.00) 0.705 14.0 15.0
- 7. Probable maximum hurricane and spring high tide Probable maximum hurricane
+17.5 13.5 14.5
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-35 of 2-123 Revision 0, 2020 2.5 FIGURES Figure No.
Title Figure 2.5-1 Map & Description Showing Location of Sources of Potable &
Industrial Water Supplies & Watershed Areas Figure 2.5-2 Hudson River Drainage Basin
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-36 of 2-123 Revision 0, 2020 2.6 Meteorology 2.6.1 General
[Historical Information] Meteorological parameters related to atmospheric transport and diffusion have been extensively investigated in the Indian Point area since 1955. Studies of the wind flow characteristics, induced by the topography surrounding the site, illustrated the unique valley wind system and the channeling of low-level winds.
Meteorological studies1-3 were conducted from 1955 to 1957 by the Research Division of New York University, under the direction of Prof. Ben Davidson, in support of Unit 1 licensing activities. Data from these studies illustrated the channeling of the air flow by the terrain into downvalley (north-northeast) and upvalley (south-southwest) regimes. Historical data collected by the U.S. Weather Bureau in 1932 also illustrated the valley wind system.
Subsequent meteorological investigations were conducted from 1968 through 1972 by New York University School of Engineering and Science, Department of Meteorology and Oceanography, under the direction of Dr. James Halitsky and Mr. Edward J. Kaplin. These studies supported the earlier findings of the valley wind system by Prof. Davidson and are documented in Appendix 2A of this DSAR and in the FSAR for Indian Point Unit 3.
The most recent meteorological programs and data analyses conducted in the Indian Point environs since 1972 were documented in a York Services Corporation report (Meteorological Update, September 1981). This report is included in Appendix 2A. The 10-m elevation on the 100-ft meteorological tower used for the Unit 2 siting studies is the backup tower to the 400-ft (122-m) primary tower. The 10-m tower installed at the Buchanan Service Center is also available as an additional contingency.
The York Services Report summarizes the meteorological activities conducted for Indian Point from 1955 to 1981. Included are topographic effects, wind correlations, data collection, diurnal wind distribution, trajectory analyses, atmospheric stability, and wind distributions. The report substantiates previous studies conducted on the existence of the valley wind system in the environs of Indian Point.
2.6.2 Historical Information - Application of Site Meteorology to Safety Analysis of Loss-Of-Coolant Accident Section 6.2.1.4 describes the application of meteorology data to the analysis of the Fuel Handling Accident. The following information is retained as historical information.
The atmospheric dispersion factors required for the original safety analysis were computed for the worst possible meteorological conditions that could prevail at the Indian Point site.
A search of the records indicated that the most protracted consecutive period during which the wind direction was substantially from the same direction was 5 days. The winds in this case were from the northwest and speeds ranged from 15 to 30 mph.
The most frequent wind flow at low heights under inversion conditions was down the axis of the valley. This direction, roughly 10- to 30-degrees, was also the direction of maximum wind frequency. Because of the relatively high frequency of inversion conditions associated with this wind direction, the original safety analysis assumed that the distribution of wind speed and
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-37 of 2-123 Revision 0, 2020 thermal stability during the hypothetical accident was exactly that measured at the 100-ft tower level for the 5-to 20-degree wind direction.
The valley wind is diurnal in nature, that is, up-valley during unstable hours and down-valley during stable hours. In general, these local winds are most frequent under clear sky and relatively light prevailing wind conditions. The diurnal variation of the vector mean wind as measured 70-ft above river during September-October 1955 is shown in Figure 2.6-1 for conditions in which the large-scale flow was virtually zero (12 days) and in Figure 2.6-2 for conditions in which the large-scale flow (geostropic wind) was less than 16 mph (35 days). It may be seen that for these virtually stagnant prevailing wind conditions, there is a regular diurnal shift in wind direction and that the mean vector wind associated with the down-valley flow is approximately 6 mph.
A measure of the magnitude of the diurnal shift in wind direction is shown in Figure 2.6-3, where the steadiness of the wind (vector) mean speed over the mean scalar speed is shown as a function of time and the strength of the prevailing flow. Where the steadiness is close to one, the persistence of a given wind direction is very high. These data indicate that a consecutive 24-hr down-valley flow with light wind speeds and inversion conditions is extremely improbable due to the diurnal variation of the steadiness.
The original safety analysis of the loss-of-coolant accident assumed that the accident occurred during down-valley inversion flow conditions and that this condition persisted for 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> with average wind speeds slightly less than 2 m/sec. Figures 2.6-1 and 2.6-2 indicate that the duration of the down-valley flow is about 12-hr rather than 24-hr and that the vector mean wind speeds are approximately 2.5 m/sec.
In view of the discussion above, it was concluded that the original safety analysis for the first 24-hr is conservative to within a factor of about 2.
The remainder of the original safety analysis assumed that for the next 30 days, 35-percent of the winds were in the 20-degree sector corresponding to the nocturnal down-valley flow and that wind speed and thermal stability were as observed over the period of 1 year as measured at the 100-ft tower location. If the observations were distributed uniformly throughout the year, slightly over 100 hr per month of 5-to 20-degree winds could be expected to occur. The original analysis assumed that 276-hr of 5-to 20-degree winds occurred in the first 31 days after the accident, and that about 130 of these hours were characterized by inversion conditions.
Approximately 35 weak-pressure gradient days were observed in September-October 1955 or about 430 hr per month. From Figure 2.6-3, the hour during which the down-valley flow is quite persistent under weak-pressure gradient conditions are from 0 to 8 hr. Assuming that the steadiness is 1.0 during these hours (it is in fact about 0.9 or less), the number of down-valley inversion winds per month during September and October is on the order of 140 hr per month.
This indicates that the meteorology assumed in the original safety analysis beyond the first 24-hr was reasonable for the worst months (September and October) and was undoubtedly conservative with varying degrees of conservatism for the remainder of the year.
The inversion frequency assumed for the original 30-day accident case was conservative because the evaluation was made from concurrent assumptions concerning the postulated meteorological conditions, namely:
- 1.
Inversion conditions prevail for 42.4-percent of the time.
- 2.
The wind direction is within a narrow 20-degree sector for 35-percent of the time.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-38 of 2-123 Revision 0, 2020 This was equivalent to assuming that in the model 20-degree sector, the inversion frequency is 14.8-percent for the 30-day period. The observed annual maximum inversion frequency for a 20-degree sector is 6.2-percent (p. 29, Table 3-3, Section 1.6 of Reference 3). If we assumed that the inversion frequency is spread uniformly throughout the year, almost 3 months worth of inversions in the model 20-degree sector were considered to occur in the first 31-day month after the original analyzed accident. The assumption of uniform spread of inversion frequency over the year was examined above where an attempt was made to isolate those local meteorological conditions at Indian Point, which might yield the highest 30-day dose. It was concluded that the "worst" meteorological conditions were associated with the nocturnal down-valley flow, which was most frequent during September and October.
REFERENCES FOR SECTION 2.6 [HISTORICAL INFORMATION]
- 1.
New York University, Research Division, A Micrometeorological Survey of the Buchanan, N.Y., Area, NYU Technical Report 372.1, November 1955, which was Exhibit L-1, Docket 50-3, given in its entirety. The topography of the area surrounding the site is described and the effects of the topography on meteorological conditions are discussed.
The types of data collected, the methods and frequencies of collection, the description and location of the equipment, and the general scope of the meteorological program are indicated in this report. Seasonal wind characteristics, including speeds, directions, and frequencies are tabulated.
- 2.
New York University, Research Division, Evaluation of Potential Radiation Hazard Resulting From Assumed Release of Radioactive Wastes to the Atmosphere From Proposed Buchanan Nuclear Power Plant, Sections 1, 2, and 3 of NYU Technical Report 372.3, April 1957. This report was submitted to the NRC in its entirety as Exhibit L-5, Docket 50-3. These sections discuss the diffusive conditions and the climatological data of the site. The basis for evaluating the diffusion parameters selected for the safety analysis is given on pages 19 to 21. Section 3 contains tables of frequency distribution of diffusion classes and wind directions, and also wind roses.
- 3.
New York University, Research Division, Summary of Climatological Data at Buchanan, N.Y., 1956-1957, NYU Technical Report 372.4, March 1958, was Exhibit L-6, Docket 50-
- 3. This report summarizes the final meteorological testing at Indian Point.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-39 of 2-123 Revision 0, 2020 2.6 FIGURES Figure No.
Title Figure 2.6-1
[Historical Information]
Diurnal Variation of Mean Vector Wind for Virtually Zero Pressure Gradient Conditions Figure 2.6-2
[Historical Information]
Diurnal Variation of Mean Vector Wind for 24 Hr Periods of Weak Pressure Gradient Conditions Figure 2.6-3
[Historical Information]
Steadiness of Wind as a Function of Time of Day for Indicated Pressure Gradient Conditions
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-40 of 2-123 Revision 0, 2020 2.7 Geology and Seismology
[Historical Information] The Indian Point site and surrounding area were studied in 1955 by Sidney Paige, consulting geologist, before the construction of Unit 1 In 1965, Thomas W. Fluhr, P.E., an engineering geologist, reviewed the geology of the site and made additional borings at the location of Unit 2.
In 1982, a report by Woodward-Clyde Consultants was done to update this Section. The previous studies are listed in the reference list of the report. The report is included in Appendix 2B.
Between 2005 and 2007, GZA GeoEnvironmental (GZA), performed a comprehensive hydrogeologic investigation of the site. This investigation was initiated to understand groundwater flow and contaminant transport. During this investigation numerous borings were advanced to study the site geology, hydrology and aquifer properties. Details of the geology, hydrology and aquifer properties can be found in the GZA report1.
A seismic monitoring network exists in the vicinity of the site and data from this network is periodically evaluated.
REFERENCES FOR SECTION 2.7
- 1.
GZA, Hydrogeologic Site Investigation Report for the Indian Point Energy Center, January 7, 2008.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-41 of 2-123 Revision 0, 2020 2.8 Environmental Radioactivity Monitoring for environmental radioactivity in the vicinity of the Indian Point Station began in 1958, approximately 4 years before the operation of Unit 1. Measurements since that time have indicated that the present operation of Units 2 and 3 and the past operation of Unit 1 have had no significant effect on the environment. The monitoring program implementsSection IV.B.2 of Appendix I to 10 CFR Part 50 and thereby supplements the radiological effluent monitoring program by verifying that the measurable concentrations of radioactive materials and levels of radiation are not higher than expected on the basis of the effluent measurements and the modeling of the environmental exposure pathways. Measurements of radioactivity in the environment are summarized in the Annual Radiological Environmental Operating Report, which is submitted annually as required by the facility's Technical Specifications.
Determinations of radioactivity in the environment are made regularly. Sample locations are defined in the Offsite Dose Calculation Manual (ODCM).
The overall objectives of the environmental monitoring program are as follows:
- 1. To establish a sampling schedule for Indian Point Units 1 and 2 that will recognize changes in radioactivity in the environs of the facility.
- 2. To ensure that the effluent releases are kept as low as is reasonably achievable (ALARA) and within allowable limits in accordance with 10 CFR 20.
- 3. To verify projected and anticipated radioactivity concentrations in the environment and related exposure from releases of radioactive material from the Indian Point site.
Results of environmental surveys conducted by Con Edison have been verified by the Bureau of Radiological Health Service of the New York State Health Department in previous years and presently, by the New York State Bureau of Environmental Radiation.1, 2 Environmental surveys have also been confirmed by Dr. Merril Eisenbud, Director of Environmental Radiation Laboratory, Institute of Environmental Medicine, New York University Medical Center, who has found that the levels of environmental radioactivity are associated with natural background and fallout of nuclear weapons testing.3 In a study of the radioactivity in the Hudson River, Mr. Sherwood Davis, Director, Bureau of Radiological Health Service, New York State Department of Health, et al., have concluded that the discharges from Indian Point Unit 1 "are a minute fraction of the federal limits."4 The above results were obtained in preoperational and operational periods of Units 1 and 2 in the late 1950s and in the 1960s. In the more recent years of the late 1970s, radiological impact evaluations have shown similar results. These evaluations of actual historical Unit 2 releases have been performed for inclusion in the effluent release reports and have shown that operation of the Unit 2 facility has had an insignificant impact on the environs.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-42 of 2-123 Revision 0, 2020 REFERENCES FOR SECTION 2.8
- 1.
New York State Department of Health, Division of Environmental Health Services, Consolidated Edison Indian Point Reactor, Post Operational Survey, August 1965.
- 2.
New York State Department of Health, Division of Environmental Health Services, Consolidated Edison Indian Point Reactor, Post Operational Survey, July 1966.
- 3.
New York University Medical Center Institute of Environmental Medicine, Ecological Survey of the Hudson River: Progress Report No. 2, submitted to Division of Radiological Health, USPHS, Contract PHS 86-95, Neg. 141, December 1966.
- 4.
F. Cosolito, et al., Radioactivity in the Hudson River, Symposium on Hudson River Ecology, Hudson River Valley Commission of New York, October 4-5, 1966.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-43 of 2-123 Revision 0, 2020 NOTE: This information is classified as Historical Information APPENDIX 2A FACILITY SAFETY ANALYSIS REPORT (FSAR)
CONSOLIDATED EDISON COMPANY OF NEW YORK, INCORPORATED INDIAN POINT NUCLEAR GENERATING UNIT NO. 2 METEOROLOGICAL UPDATE SEPTEMBER, 1981 YSC PROJECT + 01-4122 prepared by:
EDWARD J. KAPLAN BRUCE R. WUEBBER Senior Scientist Staff Meteorologist ATMOSPHERIC SERVICES DEPARTMENT
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-44 of 2-123 Revision 0, 2020 TABLE OF CONTENTS LIST OF FIGURES LIST OF TABLES 1.0 GENERAL 1.1 Historical 1.1.1 Introduction 1.1.2 Tower Siting and Instrumentation 1.1.2.1 Hudson River 1.1.2.2 General Topography 1.1.2.3 Site Configuration 2.0 METEOROLOGICAL PROGRAM AT INDIAN POINT 2.1 122m Meteorological Tower 2.1.1 Siting 2.1.2 Instrumentation 2.1.2.1 Sensor Configuration 2.1.2.2 Instrumentation Specifications 2.1.2.2.1 Climatronics F460 Wind Speed Transmitter 2.1.2.2.2 Climatronics F460 Wind Direction Transmitter 2.1.2.2.3 Climatronics TS-10 and TS-10WA Motor Aspirated Shields 2.1.2.2.4 Climatronics 100087, 100087 Temperature-Delta Temperature 2.1.2.2.5 Climatronics DP-10 Dew Probe 2.1.2.2.6 Climatronics 1000971 - Heated Rain -
Snow Gauge 2.1.2.2.7 Data Collection Systems 2.1.3 Meteorological Support System 2.2 Data Log 2.2.1 Indian Point Tower IP3 2.2.2 122 Meter Meteorological Tower 3.0 ANALYSES DATA
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-45 of 2-123 Revision 0, 2020 3.1 Indian Point Tower IP3 3.2 122M Meteorological Tower (IP4) 3.2.1 October 1, 1973 to August 31, 1974 3.2.2 August 1, 1978 - July 31, 1979 3.2.2.1 Surface Air Trajectories Analyses -
Summary 3.2.3 March 1980 - December 1980 3.2.3.1 General 3.2.3.2 Wind Frequency Distributions 3.2.3.3 Diurnal Wind Distributions 3.2.3.4 Resultant and Concurrent Hourly Winds 3.2.3.5 Summary - Trajectory II Study 3.2.4 January 1, 1979 through December 31, 1980 3.2.4.1 Data Analyses 3.2.4.2 Wind Frequency Distributions 3.2.4.3 Diurnal Wind Direction Distributions 3.2.4.4 Wind Speed Distributions 3.2.4.5 Wind Velocities and Atmospheric Stability 3.2.4.5.1 Joint Frequency Distribution of Wind Direction and Stability 3.2.4.5.2 Frequency of Occurrence of Stability Categories 3.2.4.5.3 Average Wind Speed and Diurnal Variation as a Function of Stability Categories 4.0
SUMMARY
4.1 Meteorology 4.1.1 General 4.1.2 122 Meter Meteorological Tower System 4.1.3 Local Meteorological Characteristics 4.1.4 Conclusion
5.0 REFERENCES
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-46 of 2-123 Revision 0, 2020 LIST OF FIGURES Figure No.
Title Figure 1 Ground Contours at Elevation 200 Feet Figure 2 Ground Contours at Elevation 400 Feet Figure 3 Elevations in the Indian Point Region Figure 4 Water Courses in the Indian Point Region Figure 5 Existing and Historical Meteorological Towers at Indian Point Figure 6 Indian Point Meteorological Site Figure 7 Tower Configuration Figure 8 Station Configuration Figure 9 Indian Point - Meteorological Support Systems Figure 10A Two Station Wind Correlation Data Period - October 1973 Figure 10B Two Station Wind Correlation Data Period - December 1973 Figure 11 Position of One Mile Grid in Relation to Topographic Features Figure 12 Position of Wind Files on Grid Figure 13 Average March, 1980 East and West Bank Diurnal Wind Distributions Figure 14 Average June, 1980 East and West Bank Diurnal Wind Distributions Figure 15 Average December, 1980 East and West Bank Diurnal Wind Distributions Figure 16 Locations of Monitoring Sites in Relation to One Mile Grid Figure 17 Comparison of 10M Level Diurnal Wind Distributions Figure 18 Comparison of 122M Level Diurnal And Wind Distribution Figure 19 Diurnal Distribution of Wind Speeds Figure 20 Percent Probability Distribution of Wind Speeds
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-47 of 2-123 Revision 0, 2020 LIST OF TABLES Table 1 Tower and Instrumentation Record Table 2 Valid Data Log Table 3 Comparison of Annual Percent Occurrence of Stability Categories Table 4 Summary of Trajectory End-Points Table 5 Summation of Trajectory End Points - August, 1978 Table 6 Summation of Trajectory End Points - January, 1979 Table 7 Summation Trajectory Occurrences South of Indian Point Table 8 Locations of Stations Relative to Indian Point Table 9 Valid Data for Trajectory Wind Sites Table 10 Frequency Distribution of 24 Hour Resultant Wind Directions Table 11 Summary of Two-Station Wind Correlations Piermont (Site 1)
Referenced to Selected Monitoring Locations (Site 2)
Table 12 Concurrence of Two-Station Wind Directions Table 13 Diurnal Distribution of Occurrences of Eight-Hour Trajectories With On Grid Reversals Table 14 Summary of Trajectory End-Point Counts Table 15 Summary of Trajectory End-Points (Percent)
Table 16A Historical Comparisons of Wind Frequency Distributions - March Table 16B Historical Comparisons of Wind Frequency Distributions - July Table 16C Historical Comparisons of Wind Frequency Distributions - December Table 17 Comparison of Percent Wind Frequency Distributions - Summer Table 18 Comparison of Percent Wind Frequency Distributions - Winter Table 19 Comparison of Diurnal Resultant Wind Directions Table 20 Indian Point (10M) Wind Speed (MPH) - Summer Season Table 21 Indian Point (10M) Wind Speed (MPH) - Winter Season Table 22 Indian Point (122M) Wind Speed (MPH) - Summer Season Table 23 Indian Point (122M) Wind Speed (MPH) - Winter Season Table 24 Maximum Diurnal Wind Speed (MPH)
Table 25 Annual Summary of Wind Direction Percent Frequency Distribution As A Function of Stability - 10M Level Table 26 Summary of Wind Direction Percent Frequency Distribution As A Function of Stability - Summer Season Table 27 Summary of Wind Direction Percent Frequency Distribution as A Function of Stability - Winter Season Table 28 Historical Comparisons of Percent Occurrence of Stability Table 29 Comparison of Percent Occurrence of Stability on 122 Meter Tower Table 30 Diurnal Variation of Stability Class and Wind Speed (10M)
Table 31 Diurnal Variation of Stability Class and Wind Speed (122M)
Table 32 Diurnal Variation of Stability Class and Wind Speed (Delta-T 400-200)
Table 33 Comparisons of Average Wind Speeds (MPH) As A Function of Stability
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-48 of 2-123 Revision 0, 2020 FACILITY SAFETY ANALYSIS REPORT (FSAR)
CONSOLIDATED EDISON COMPANY OF NEW YORK, INC.
INDIAN POINT NUCLEAR GENERATING UNIT 2 METEOROLOGICAL UPDATE 1.0 GENERAL 1.1 HISTORICAL BACKGROUND 1.1.1 Introduction Meteorological data were initially collected and evaluated with respect to Indian Point, Buchanan, New York and its environment during the period from 1955 through 1957. This work was accomplished under the direction of Professor Benjamin Davidson of New York University under contract with the Consolidated Edison Company of New York, Inc. (Con Edison). The data and studies during this period were the bases for the Environmental Reports relevant to Indian Point Nuclear Generating Units 1, 2 and 3.
With respect to the Facility Safety Analysis Report (FSAR) for Unit 2, the Environmental Report Supplement, Appendices Volume 1 as Appendices C, D and E contains:
NYU Technical Report 372.1 (November, 1955), B. Davidson NYU Technical Report 372.3, Section 2 and 3, (April, 1957), B. Davidson and J.
Halitsky NYU Technical Report 372.4 (March, 1958), B. Davidson In 1968 under the direction and supervision of Dr. James Halitsky of New York University, Con Edison contracted to establish experimental meteorological monitoring, data collection and evaluation activities at the Indian Point site and at specified sites in its environment (Halitsky, Laznow and Leahy, February 1970). The original purpose of the above investigation, as noted in the reference, was modified after the studies had begun in order to provide the AEC Construction Hearings for Indian Point Unit 3 with clarification of aspects of the 1956-1957 meteorological data base for the Units 1, 2 and 3 diffusion models. This phase of data collection began in December, 1969.
A report dealing with the results of this latter phase (Halitsky, Kaplin and Laznow, NYU GSL Technical Report No. TR 7103, May 1971) appears as Appendix G in the FSAR Unit 2 Environmental Report Supplement Appendices Volume 1 and as Supplement 1 in the FSAR for Unit 3. The focus of the above report was to validate present site meteorology as representing no significant change in relation to site meteorology from the 1955-1957 period.
Data collection and evaluations continued under this program and a report was submitted by Kaplin and Laznow (1972) representing the data collection period from 1 January, 1970 through 31 December 1971. A copy of this report appears in FSAR for Unit 3 as Supplement 10 (January, 1973).
With respect to Indian Point on-site meteorological measurements, there were for the purpose of the reports that have been cited, three different meteorological towers at three different locations. These are specifically delineated in Figure 1 of Halitsky, Kaplin and Laznow (1971).
The meteorological data collected during the 1955-1957 were from the 300 Foot Tower designated as IP1. Meteorological data collected and reported by Halitsky, Kaplin and Laznow
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-49 of 2-123 Revision 0, 2020 (1971) and Kaplin and Laznow (1972) were from the 100 Foot Tower designated as IP3. The base of IP3 Tower was about 200 feet from the base location of the original IP1 Tower.
Using input data meteorological data from Indian Point Tower (IP3), Bowline Point and the Cape Charles along with sequences of upper air pilot balloon observations Kaplin, Laznow and Wurmbrand (1972) provided Con Edison with input information for the location of the 90-percent probability air monitoring sites, overlay patterns for the prediction of the distribution of gaseous releases and evaluation of the requirements of the AEC Safety Guide 23 (1972).
All data on the IP3 Tower were collected in accordance with U.S. AEC Safety Guide No. 23, On-Site Meteorological Programs as delineated 2/17/71. The IP3 Tower was maintained from March 1972 through December 1973 by York Research Corporation, Stamford, Connecticut under contract with Con Edison. The last formal report for this tower was prepared and submitted to Con Edison by Kaplin and Kitson (1974) for the 1973 data collection period.
In April of 1973, York Research Corporation under contract with Con Edison began work on the erection of an on-site 400 Foot Meteorological Tower approximately 1725 feet-S and 1750 feet-W of the IP3 Tower. The function of this tower was to develop micro-climatological data suitable for the design of cooling towers and the evaluation of their potential environmental impact on the Indian Point site and its environs. Concurrent studies were conducted to develop three dimensional aspects of the local valley flow using pibal balloons, constant level tetroons and balloon-sondes. In addition, a concurrent study was conducted to develop background levels of ambient air salt concentrations. The results of these studies were submitted in two reports:
Kaplin, Kozenko and Kirshner (1974) and Kaplin, Kitson and Kozenko (1974). This latter report compared meteorological data from the IP3 Tower. At the conclusion of 1973, the primary source of reduced on-site meteorological data were from the IP4, 400 Foot Meteorological Tower. IP3 Tower systems maintenance was continued in accordance with Safety Guide 23 through October 1, 1976 and meteorological data were recorded on analog charts. Data collection was transferred to the IP4 Tower on July 1, 1976. The 400 Foot Tower (IP4) servicing, maintenance and data collection and data selective processing is on-going. Its systems have been updated to meet present requirements of NUREG-0654 Appendix 2 (1980) and proposed Revision 1 to NRC Safety Guide 1.23 (1980).
The continued maintenance services, etc., of the 400 Foot Meteorological Tower by York Research Corporation/York Services Corporation was continuous under contract with Con Edison until September 30, 1978, and from October 1, 1978 through the present time under contract with the Power Authority of the State of New York (PASNY).
In September, 1979, York Services Corporation under contract with Con Edison began a study of north to south surface air trajectories analyses and evaluations based on real-time wind data available from the Indian Point vicinity. This study incorporated local wind velocity data from the 400 Foot Meteorological Tower at Indian Point, the Orange and Rockland Utilities, 350 Foot Meteorological Tower in Haverstraw, New York, as well as from selected U.S. Department of Commerce, NOAA, Weather Stations. For this study, meteorological data were analyzed and evaluated for the period from August 1, 1978 through July 31, 1979. The final results of this study were presented in reports: Kaplin, E.J. and B. Wuebber, (1979) and Kaplin, E.J. (1979).
As an outgrowth of these studies an expended network of surface (10M) wind velocity monitoring stations were sited at key locations along the Hudson River Valley north and south of Indian Point and inland to the east. This network consisted of new anemometer stations in addition to the Indian Point 400 Foot Meteorological Tower, the Bowline 350 Foot Meteorological Tower and the U.S. Department of Commerce, NWS Station at Westchester
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-50 of 2-123 Revision 0, 2020 County. These wind data were digitalized and evaluated by New York Services Corporation under contract to Con Edison for the purposes of defining surface air flow patterns within a 10-15-mile range of Indian Point with emphasis on generating refined estimated of southward movements. As completed, ten consecutive months (March 1, 1980 - December 31, 1980) were evaluated and a total of 7,264 eight-hour parcel trajectories were created objectively using appropriate local one-hour wind velocity averages on a real time basis. The results of this study were submitted to Con Edison: Kaplin, Edward J. and B. Wuebber (1981).
For the purpose of this FSAR, second meteorological update, meteorological data have been analyzed and evaluated from the 400 foot (122 Meter) Indian Point Meteorological Tower for the two year period from January 1, 1979 through December 31, 1980.
1.1.2 Tower Siting and Instrumentation 1.1.2.1 Hudson River There are a number of pertinent facts about the Hudson River itself that are relevant to its ability to induce and/or influence mesoscale flow phenomena that are dominant factors in the Indian Point environs. The most important factor is that it is not a river but, rather a tidal estuary. From New York City, 154-miles north to Troy, there is no drop in the surface elevation of the river.
Except for spring runoff from the Andirondacks, which can smother the tide down to Albany, there is almost imperceptible downstream current.
Since there is no slope to the river surface, it will not support its own gravity flow. Any air movement within its canyons during minimal atmospheric pressure gradient periods can be strictly local cells, which may actually block continuous horizontal air movement over the water surface.
Thermally induced air movement of the Atlantic sea breeze follows the natural path of the river.
It has been noted, however, that Iona Island 45-miles north of the tip of Manhattan is considered the point of maximum inland intrusion. The northward movement of sea breeze does not proceed up the Hudson River Valley and Hackensack River Valley at the same speed. The inland movement along the Hackensack Valley lags the Hudson Valley movement. The Hackensack River is on the west side of the Hudson and is specifically delineated because its headwaters are just south of the South Mountains and isolated from the Hudson River by the Hook Mountains and the Palisades. The South Mountains are the east-west extension of the Hook Mountains. The South Mountains abut the Ramapo Range and form a sheer wall from the Southern boundary of the west bank community of Haverstraw.
1.1.2.2 General Topography Each of the reports cited in Section 1.1.1 describe in some detail general topography in the Indian Point environs. The most recent was provided by Kaplin and Wuebber, 1981. Indian Point is located in the lower Hudson River Valley 27-miles due north of northern boundary of New York City (Manhattan Island).
The Indian Point area has been described by Halitsky, et. al., 1970, as being located roughly on the axis of a north-south valley enclosed by the Dunderberg and Buckberg Mountains to the west and Blue Mountain and Prickly Pear Hill on the east. The shape of the valley at the 200 foot and 400 foot elevation levels are given in Figures 1 and 2. At the 200 foot contour level the
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-51 of 2-123 Revision 0, 2020 valley width is two miles at Dunderberg Mountain and opens southward to a width of five miles at Prickly Pear Hill.
The Hudson River, flowing southward through the valley, resembles a gourd with its curved 3/4-mile thick northern neck nestling at the base of Dunderberg Mountain while the bulbous three mile thick body fills the southern part of the valley between South Mountain and Prickly Pear Hill. The Indian Point peninsula lies in the hollow of the curved neck.
Beyond its northern end, the valley is split into two branches by Manitou Mountain. The Hudson River passes through the steep, narrow northwest branch between Manitou and Dunderberg Mountains. The northeast branch, between Manitou and Blue Mountains, is about 1.5-miles wide at Manitou Mountain but degenerates with distance into three tributary valleys containing Annsville Creek, Sprout Brook and Peekskill Hollow Brook with sources in the mountainous region north of Peekskill.
South of Haverstraw Bay, the valley opens up rapidly to the southeast while the west bank of the Hudson River follows the blocking of the east-west orientated South Mountains to assume a southward course along the Hook Mountains to the Palisades Mountains.
At elevations higher than 200 feet the solidity of the eastern wall of the valley breaks, first between Blue Mountain and Prickly Pear Hill to form at 300 feet the irregular drainage system, which supplies Furnace Brook, and then at 400 feet into an irregular array of mountain tops.
The western wall is till fairly solid at 300 feet but breaks at 400 feet into two well-defined valleys containing Cedar Pond and Minisceongo Creeks. However, just to the west are Ramapo Mountains whose elevations exceed 1000 feet. Figures 3 and 4 (Kaplin and Wuebber, 1981) show the elevations of significant mountain peaks and water courses in the region of Indian Point.
1.1.2.3 Site Configuration The location of the specific meteorological towers associated with earlier studies in the Indian Point environs are available in Figure 1 of Kaplin and Laznow (1972), FSAR 3, Supplement 10, 1973 and in Figures 1a and 1d of Kaplin, Kitson and Kozenko (1974).
Table 1 lists the operational periods and the instrumentation associated with each tower. Not included in this listing are those wind monitoring sites that were used for the most recent study (Kaplin and Wuebber 1981, Sec. 2.4 & 2.5). In this study, an 11 site monitoring network was established equipped with Climatronics Mark III, wind speed and direction systems. This network was operable for all or part of the period from March, 1980 through December, 1980.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-52 of 2-123 Revision 0, 2020 TABLE 1 TOWER AND INSTRUMENTATION RECORD (INCLUDES PARAMETERS NOT REQUIRED BY PROPOSED SAFETY GUIDE 1.23)
Meteorological Base Elevation Operational Period Exposure Station Ft. MSL From To Parameter Instrument M. Above Grade Indian Pt (IP1) 130 1956 1957 Wind Temp. Diff.
Aerovane Honeywell 91 & 30 91-2 & 30-2 USS Jones (J) 0 1956 1957 Wind Aerovane 21 Indian Pt (IP2) 60 1968 1969 Wind Temp. Diff.
Climet Bristol 30 29 - 1.5 Montrose (MP) 60 1968 6/71 Wind Climet 30 Bowline Pt (BP) 5 9/68 11/69 Wind Climet 30 11/69 8/72 Wind Aerovane 30 9/68 11/69 Temp. Diff.
Honeywell 30 - 3 11/69 2/72 Temp. Diff.
Bristol 30 - 3 2/72 8/72 Temp. Diff.
Climet-(Rosemont) 30 - 3 Bowline Tower 10 Note 2 Present Wind Climatronics 100, 50 & 10 Note 2 Present Temp. Diff.
Climatronics 100-10 & 50-10 Trap Rock (TR) 90 1969 7/72 Wind Climet 30 USS Cape Charles (CC) 0 3/70 9/70 Wind Aerovane 30 Indian Pt (IP3) 120 11/69 9/76 Wind Aerovane 30 11/69 9/76 Wind Climet 30 6/73 9/76 Wind Climet 10 Backup Met System (IP3) 12/81 Present Wind Climatronics 10 11/69 10/71 Temp. Diff.
Honeywell 29 - 2 8/72 9/76 Temp. Diff.
Climet-(Rosemont) 30-3 & 9-3 8/72 9/76 Amb. Temp.
Climet-(Rosemont) 9 8/72 9/76 Dew Point Climet-(Foxboro) 30,9 & 3 8/72 9/74 Net Radiation Teledyne Geotech 9
5/70 12/70 Turbulence Bivane*
30 Note 2 -
Bowline Tower is located at approximately Latitude 41° 13N and Longitude 73° 58 W. This location is about 3000 feet NW of the earlier Bowline Point Tower. It began operation in the 1972/73 time period.
- Intermittent usage.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-53 of 2-123 Revision 0, 2020 TABLE 1 (Contd)
Meteorological Base Elevation Operational Period Exposure Station Ft. MSL From To Parameter Instrument M. Above Grade Indian Pt (IP4) 117 9/73 Present Wind Climatronics 122, 38 & 10 122 M. Tower 9/73 6/80 Wind Climatronics 85 - Note 1*
6/80 Present Wind Climatronics 60 9/73 9/79 Amb. Temp.
EG & G 10 9/79 Present Amb. Temp.
Climatronics 10 9/73 9/79 Dew Pt.
EG & G 122, 61 & 10 9/79 Present Dew Pt.
Climatronics 10 9/73 9/79 Temp. Diff.
EG & G 122-10 & 61-10 9/79 Present Temp. Diff.
Climatronics 122-10 & 60-10 1/74 Present Net Rad.
Teledyne Geotech 10 7/80 Present Precipitation Climatronics 1
Indian Pt (IP4) **
117 9/73 7/77 Visual Range EG & G FSM 10 10M Tower Emergency Control Center #
135 7/24/80 11/81 Wind Climatronics 11.8 Note 1* -
85 meter wind speed and wind direction moved from the 85 meter level to the 60 meter level as required by proposed Revision 1 to NRC Safety Guide 1.23.
- Tower and System Removed 07/22/80.
- Tower and System Removed 07/22/80.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-54 of 2-123 Revision 0, 2020 2.0 122M METEOROLOGICAL TOWER 2.1.1 Siting The relative locations of the existing meteorological towers in historic perspective are shown in Figure 5. Specific details of site location are shown in Figure 6.
2.1.2 Instrumentation 2.1.2.1 Sensor Configuration The sensor configuration and exposure on the existing operational 122M Meteorological Tower are shown in Figures 7 and 8.
2.1.2.2 Instrumentation Specifications The following specifications apply to specific operational sensors that are a part of the total meteorological support systems at Indian Point.
2.1.2.2.1 Climatronics F460 Wind Speed Transmitter Accuracy:
0.07 M/S or 1%
Range:
0-56 M/S Threshold:
0.22 M/S Distance Constant:
1.5 M 2.1.2.2.2 Climatronics F460 Wind Direction Transmitter Accuracy:
+/-2° Range:
0-540° Threshold:
0.22 M/S Distance Constant: 1.5 M Damping Ratio: 0.4 at 10° initial angle of attack 2.1.2.2.3 Climatronics TS-10 and TS-10WA Motor Aspirated Shields Shield Effectiveness:
Under radiation intensities of 110 W/m3 (1.6 cal/cm2/min) radiation error not exceeding 0.1°C Aspiration Rate:
3 M/S at sensor location 2.1.2.2.4 Climatronics 100087, 100087 Temperature-Delta Temperature (matched thermistor)
Temperature:
Range:
-34 to +50°C Accuracy:
+/- 0.2°C Time Constant:
10 sec. To 63% (in TS-10 Shield)
Linearity:
+/- 0.2%
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-55 of 2-123 Revision 0, 2020 Delta Temperature:
Range:
+/- 10°F Sensitivity:
0.02°F Accuracy:
0.1°F or +/- 5% of delta-T not to exceed 0.3°F Response Time:
10 sec. To 63% in TS-10 Shield 2.1.2.2.5 Climatronics DP-10 Dew Probe (YSI Lithium Chloride)
Range:
-40° to 42°C Accuracy:
+/- 0.5°C Response Time:
1°C/min.
2.1.2.2.6 Climatronics 1000971 - Heated Rain - Snow Gauge (Tipping Bucket)
Accuracy:
+/- 1% up to 3/hr Resolution:
0.01 Size:
8 diameter x 24 height Conversion Accuracy:
+/- 0.2%
2.1.2.2.7 Data Collection Systems Analog:
Wind Systems:
Esterline-Angus Model E1102R - Rectigraph Recorders Temperature, Dew Point, Delta Temperature: Tracer Westronics Model M11E, Multipoint Precipitation:
Esterline-Angus Model MS 401C Digital:
Climatronics Data Processor:
1MP/801 Tape Collection Interface:
Tandeberg TD1 10-50 2.1.3 Meteorological Support System The meteorological systems at Indian Point are equipped, maintained and operated in compliance with the specification of NUREG-0654, Appendix 2 (1980); Proposed Revision 1 to NRC Regulatory Guide 1.23 (1980); and applicable regulatory requirements. The total system as presently operated is outlined in Figure 9.
2.2 DATA LOG 2.2.1 Indian Point Tower IP3 Meteorological data from the IP3 Tower were reduced and evaluated (Kaplin and Kitson, 1974) through December 1973. From the period 1974 through September 1976 the tower system was maintained, as previously noted. Analog records were provided to Con Edison for storage. Tower removed from service in September, 1976. (Reactivated as site for Backup Wind System: 12/01/81.)
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-56 of 2-123 Revision 0, 2020 2.2.2 122 Meter Meteorological Tower (IP4)
The data log for the 122 Meter Meteorological Tower for the period from October 1973 through August 1974 can be found in Kaplin, et. al., 1974. Subsequent to the completion of the above report and the data contained therein, the meteorological analog charts and the data collection magnetic tape were documented and transmitted to Con Edison for storage.
Commencing in August 1977, wind velocity data at the 10 and 122 meter levels and the delta temperatures: 60-10M and 122-10M were reduced to hourly averages and transmitted to Con Edison in addition to the analog charts. The summary of valid data for these parameters for the period from August 1977 - July 1981 is shown in Table 2 on concurrent and total hours basis. The concurrent basis assumes that if any parameter is missing. The total basis relates an individual missing data hour to the total number of possible data hours in a month.
On the concurrent basis, the average valid data collection was 92.4 +/- 10.8-percent. On a total hour basis, the average valid data collection was 98.2 +/- 2.5.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-57 of 2-123 Revision 0, 2020 TABLE 2 VALID DATA LOG*
1977 1978 1979 1980 1981 Month Concurrent Total Concurrent Total Concurrent Total Concurrent Total Concurrent Total January N/A N/A 89.8 98.2 94.8 99.0 98.4 99.7 99.9 99.9 February N/A N/A 92.1 97.4 98.1 99.7 90.5 98.4 67.7 89.2 March N/A N/A 95.1 98.9 97.4 99.6 97.3 99.1 98.0 99.3 April N/A N/A 98.1 99.6 96.7 99.4 100.0 100.0 100.0 100.0 May N/A N/A 95.3 98.6 90.3 98.0 88.4 98.0 100.0 100.0 June N/A N/A 86.8 95.6 95.0 99.1 96.7 99.0 100.0 100.0 July N/A N/A 94.1 96.8 92.6 98.8 71.1 94.1 99.4 99.8 August 94.2 98.7 95.3 99.2 52.3 92.0 77.7 92.7 September 84.7 94.4 99.7 99.9 57.5 92.3 98.3 99.7 October 95.0 98.9 98.1 99.4 94.0 98.2 96.1 99.4 November 98.9 99.5 98.8 99.6 98.3 99.7 99.6 99.9 December 75.3 95.5 96.4 99.4 100.0 100.0 98.9 99.8 Concurrent Average:
92.4 +/- 10.8%
Total Parameter Hours:
98.2 +/- 2.5%
- Based on six (6) parameters: wind data at 10 and 122M and delta-temperatures: 60-10M and 122-10M NA - Values not available.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-58 of 2-123 Revision 0, 2020 3.0 ANALYSES DATA 3.1 INDIAN POINT TOWER IP3 A FSAR documented study with respect to the Indian Point IP3 Meteorological Tower was prepared by Kaplin and Laznow (1972) [Referenced FSAR 3 Supplement 10, 1973]. This report covered the data collection period through 1971. Additional data were subsequently provided through 1972 to provide composite joint wind velocity frequency distribution for Pasquill Stability Categories (FSAR 3 Supplement 13 and 16, 1973).
Kaplin and Kitson (1974) provided an analyses of IP3 for the period March 1973 through December, 1973.
This report confirmed the earlier study that wind data in the Indian Point environs based on monthly diurnal wind distributions, wind frequency distributions and joint wind stability categories are comprised of two seasons with little apparent transition. The winter season reflects little or no average diurnal variation in the hourly resultant winds, dominant winds from the west to north. The summer season is characterized by dominant north-northeast winds during the evening and early morning hours with a sharp transition to south to southwest winds during the day and another transition in late afternoon to the evening pattern.
The wind frequency distributions and joint frequencies as a function of Pasquill Stability Categories were comparable in 1973 with data collected in 1970 and 1971.
It is noted that the temperature gradients on the IP3 Tower were derived from delta-temperatures: 99-7 feet and wind measured at 105 feet above a grade elevation of 120 feet MSL.
Kaplin, et. al., (1974) compared three months (October - December, 1973) of IP3 wind data as measured at 105 feet above grade with concurrent three months of data from the 125 foot level on the 122 Meter Meteorological Tower (IP4) (grade elevation:
approximately 117 feet MSL) using a two station wind correlation program (Appendix B, Kaplin, et. al, 1974).
Figures 10A and 10B show the relationships obtained for October and December, 1973.
The November results were similar with the directional relationships falling between that obtained for October and December. The maximum variations between the two sites occurred with winds from E-ESE and SW to WSW. These corresponded to sectors of minimum average wind speeds. Deviations between the two sites can be attributed to local factors including terrain elevation, land use and ground cover.
The wind direction displacement effects found in the two station correlations were confirmed in the monthly diurnal analyses.
3.2 122M METEOROLOGICAL TOWER (IP4) 3.2.1 October 1, 1973 to August 31, 1974 The purpose of the 122M Meteorological Tower at Indian Point (IP4) was to develop a three dimensional micro-climatological data file to be used to assess the impact of proposed cooling towers and to provide the basis for design criteria as required. The results of one year of operation of this tower were presented in a final report (with Appendices) by Kaplin, et. al., 1974.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-59 of 2-123 Revision 0, 2020 Except as noted in the previous section, the meteorological data collected and evaluated were not compared at the time of this study with historical meteorological data associated with FSAR 2.
This study determined that the two distinctive seasonal patterns existed at each of the four levels of wind velocity measurement: 10M, 38M, 85M and 122M. Wind directions tended to back with elevation assuming an orientation parallel to general terrain contours.
In times of weak synoptic pressure gradient patterns, there were abrupt transitions in the diurnal flow patterns consistent with valley flow winds particularly during the summer season. These transitions began at the surface and progressed up to the 122M level.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-60 of 2-123 Revision 0, 2020 TABLE 3 COMPARISON OF ANNUAL PERCENT OCCURRENCE OF STABILITY CATEGORIES Stability Category Year Tower Gradient (M)
A B
C D
E F
G 1970 IP3 29 - 3 21.68 2.20 3.39 33.35 24.75 9.01 5.62 1971 IP3 29 - 3 19.17 2.75 2.97 22.74 30.87 11.69 9.75 1970-72 IP3 29 - 3 16.25 1.82 2.95 29.71 26.61 13.27 9.45 1970-72* IP3 29 - 3 6.76 2.67 2.13 32.65 40.57 11.78 3.31 1973 IP3 29 - 3 23.14 3.16 3.70 20.87 25.02 13.89 10.23 1973-74 122M-IP4 60 - 10 10.35 3.21 2.94 25.38 44.86 11.35 1.91 1979 122M-IP4 60 - 10 12.27 3.25 3.86 29.30 40.39 8.83 1.31 1980 122M-IP4 60 - 10 13.32 4.06 4.60 29.81 33.97 11.34 2.07 1979-80 122M-IP4 60 - 10 12.80 3.66 4.23 29.56 37.17 10.08 1.69
- Temperature difference corrected by a factor of 0.605; (FSAR 3, Supplement 16, April 1973)
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-61 of 2-123 Revision 0, 2020 The morning transition during the summer season was sharply defined. At 0800 EST all levels had approximately the same resultant wind direction. The evening transition began just after 1800 EST and was sharply defined a the 10M and 38M levels. The 10M level reached its nocturnal northeast drainage wind by 2100 EST along with the somewhat more erradic 38M level. The 85M and 122M levels rotated systematically and did not reach their nocturnal directions (NNE-N) until 0200 EST. The systematic rotations are referenced to the average diurnal distributions on a real time basis, the upper wind levels could be disconnected from the lower wind levels with an intermediate shear zone generated by winds up to 180° out of phase.
The resultant winds of the 122M Tower (IP4) associated with the diurnal variation curves for the summer season, veered after the morning transition until about noontime, then steadied out at SW-WSW before backing into the nocturnal pattern after the evening transition. The resultant summer season winds for the IP3 Tower (Kaplin and Laznow, 1972) in 1970 and 1971 veered throughout the entire day. In Kaplin and Kitson (1974),
the summer IP3 diurnal resultant winds exhibited the veering - backing trait. Kaplin and Laznow (1972) indicated that the question of backing or veering was related, on any given day, not only to strength of the valley drainage flow wind but also to relative strength of local land-sea circulations.
On an annual basis there were no significant differences between the percent frequency distribution of occurrences of stability categories (Pasquill) between the adjusted composite year 1970-1972 for IP3 (FSAR 3, Supplement 16, April 1973) and lower temperature gradient level on the 122M Tower (IP4). These comparisons are shown in Table 3. It is presumed that if all individual years of IP3 data were similarly adjusted prior to classification, they would also be reasonably comparable to results based on the temperature gradient 60-10M on the 122M Tower.
3.2.2 August 1, 1978 - July 31, 1979 Wind velocity data (10M level) from the 122M Meterological Tower at Indian Point and the Orange and Rockland Utilities, Inc. 100M Meteorological Tower were used to evaluate the path of air parcels in the Indian Point environs without considering stability (Kaplin and Wuebber, 1979 and Kaplin, 1979).
Each hour a parcel movement was initialized from Indian Point. Each parcel was projected forward for eight consecutive hours in hourly increments. The average wind velocity at 10M level of the 122M Tower was used to determine the speed and direction of the parcel for its initial hour increment. Subsequent movement of each parcel was determined by the location of the parcel after the initial hour on a zone of influence file that assigned a wind vector to that location: Indian Point or Bowline.
Prior to usage the wind velocity for selected 1978-1979 data were assessed by comparison with historical data files (1973-1974) at Indian Point. There were no variations that could not be accounted for by climatological variations of at least synoptic scale when assessed with reference to U.S. Department of Commerce, NOAA, EDS, LOCAL CLIMATOLOGICAL DATA for LA GUARDIA AIRPORT, NEW YORK and SIKORSKY AIRPORT, Bridgeport, CONNECTICUT.
In considering persistent southward movement of an air parcel from Indian Point assuming that Bowline would be representative of air movement south of Grassy Point, an examination of resultant winds for August 1978 and January, 1979 (typical summer
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-62 of 2-123 Revision 0, 2020 and winter seasons) indicated that such movements did not occur. While concurrent hourly average north winds were found 14 times in August and 17 times in January, these occurrences represent only 13.3-percent and 16.5-percent of all north winds relative to all north winds at Bowline. These results were anticipated, particularly during periods of light winds and weak synoptic pressure fields, from the opposing patterns of the diurnal variation curves for the two monitoring sites.
3.2.2.1 Surface Air Trajectories Analyses - Summary Trajectory end points were derived on an objective basis using surface wind data from monitoring stations. The use of observed wind data appropriate to the moving air parcels location at a given time is important since these data inherently account for local wind pattern aberrations that may be of topographic and/or unique micro-meteorological origin. No individual atmospheric stability category was explicitly considered.
The ability of the derived trajectories to generate realistic movement patterns is contingent on having sufficient wind monitoring sites to define the actual wind flow field in and around the area of interest on a concurrent real time basis.
The area of interest was limited to ten miles south of Indian Point. For practical purposes the study area was 21 x 21 square miles subdivided in a one mile grid as shown in Figure 11. Indian Point was located near the top center of the area at grid point 10, 16. This allowed for 15-miles of due south movement. The South, Hi Tor and Hook Mountains are emphasized because of the barrier that they form for air movement due south of Indian Point.
Trajectories were generated for each of the 12 months in the data file based on Indian Point and Bowline wind data. These were the only available data applicable to the study area. Trajectories were created for up to eight consecutive hours of movement.
For the first hour of the trajectory, Indian Point was used as the origin of an air parcel, which would travel a distance and in a direction determined by the hourly average wind velocity at the 33 (10M) level of the Meteorological Tower. Subsequent movement depended on the location of the trajectory end point after the first hours movement.
Zones for which the Bowline and Indian Point wind velocity measurements were considered as representative had been previously assigned. Trajectories for each hour of the month were computed. The end points were accumulated as summations of occurrences in their appropriate grid squares. In the process of generation, all end points were moved and accumulated whether or not they were in the 21 x 21-mile square. Only those end points within the study area boundary appear on tabular printouts. In any given period, an end point could pass out of the grid and move back in at a subsequent time interval.
For August, 1978, and January, 1979, two different patterns of weather station representative areas were used as shown in Figure 12. Pattern 1, which was used for all 12 months of data, had Bowline winds dominating after passage of a line three miles south of Indian Point (through Grassy Point). Pattern 2, used for August and January only, moved this line one mile further north (through Stony Point). The influence patterns are the same for the first hours movement.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-63 of 2-123 Revision 0, 2020 A summary of the August, 1978 and January, 1979, results in terms of percent of total possible trajectory end points remaining in the 21 x 21-mile area for selected trajectory time periods is shown in Table 4.
TABLE 4
SUMMARY
OF TRAJECTORY END-POINTS August, 1978 January, 1979 Pattern I No. of Occur.
% Total No. of Occur.
% Total Hour 1 722 (729) 99.0 707 (721) 98.1 Hour 2 617 (728) 84.8 486 (720) 67.5 Hour 4 420 (726) 57.9 225 (718) 31.3 Hour 6 312 (724) 43.1 157 (716) 21.9 Hour 8 206 (722) 28.5 113 (714) 15.8 Pattern II Hour 1 722 (729) 99.0 707 (721) 98.1 Hour 2 595 (728) 81.7 486 (720) 67.5 Hour 4 414 (726) 57.0 226 (718) 31.5 Hour 6 308 (724) 42.5 157 (716) 21.9 Hour 8 207 (722) 28.7 115 (714) 16.1
( ) =Total number of trajectories generated.
The actual number of points within the grid network does not differentiate between those points that have never left the network and those that have recirculated. This feature takes on added importance if total distance of travel is a consideration.
Summaries of occurrences within designated grid sectors are shown in Table 5 for August, 1978 and Table 6 for January, 1979. In terms of totals in the grid area, there is no significant effect of influence pattern assignment. This effect does show up in Tables 5 and 6 when the occurrences south of Indian Point are totaled. For this purpose, a SW sector is defined encompassing the area below Indian Point from the grid edge to ordinate Line 9. The S sector extends one mile south of Indian Point along ordinate
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-64 of 2-123 Revision 0, 2020 TABLE 5 SUMMATION OF TRAJECTORY END POINTS AUGUST, 1978 SECTOR KEY 17-21 NW N
NE 16 W
I.P.
E 1-15 SW S
SE 1-9 10 11-21
% TOTAL 35 164 133 46.0 HR 1 26 8
15 6.8 232 84 25 47.2
% TOTAL 40.6 35.4 24.0 99.0 PATTERN 1 PATTERN 2
% TOTAL
% TOTAL 52 93 109 41.2 52 93 109 42.7 HR 2 20 10 7
6.0 18 10 7
5.9 192 51 83 52.8 148 50 108 51.4
% TOTAL:
42.8 25.0 32.2 84.8
% TOTAL 36.6 25.7 37.6 81.7
% TOTAL
% TOTAL 43 38 40 28.8 44 38 36 28.5 HR 4 7
2 2
2.6 7
1 2
24.4 128 27 133 68.6 111 29 146 69.1
% TOTAL:
42.3 16.0 41.7 57.9
% TOTAL 39.1 16.4 44.4 57.0
% TOTAL
% TOTAL 33 19 18 22.4 30 19 19 22.1 HR 6 7
0 1
2.6 6
0 1
2.3 100 10 124 75.0 86 17 130 75.6
% TOTAL:
44.9 9.3 45.8 43.1
% TOTAL 39.6 11.7 48.7 42.5
% TOTAL
% TOTAL 28 6
4 18.4 28 6
4 18.4 HR 8 3
0 1
1.9 3
1 1
2.4 67 7
90 79.6 53 15 96 79.2
% TOTAL:
47.6 6.3 46.1 28.5
% TOTAL 40.6 10.6 48.8 28.7
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-65 of 2-123 Revision 0, 2020 TABLE 6 SUMMATION OF TRAJECTORY END POINTS JANUARY, 1979 SECTOR KEY 17-21 NW N
NE 16 W
I.P.
E 1-15 SW S
SE 1-9 10 11-21
% TOTAL 25 52 86 23.1 HR 1 10 10 27 6.7 154 72 271 70.3
% TOTAL 26.7 19.0 54.3 98.1 PATTERN 1 PATTERN 2
% TOTAL
% TOTAL 22 21 58 20.8 24 21 56 20.8 HR 2 14 5
16 7.2 12 5
16 6.8 133 41 176 72.0 100 45 207 72.4
% TOTAL:
34.8 13.8 51.4 67.5
% TOTAL 28.0 14.6 57.4 67.5
% TOTAL
% TOTAL 17 4
19 17.7 14 4
21 17.3 HR 4 7
0 3
4.4 7
0 3
4.4 67 16 92 77.8 57 14 106 78.3
% TOTAL:
40.4 8.9 50.7 31.3
% TOTAL 34.5 8.0 57.4 31.5
% TOTAL
% TOTAL 16 2
7 15.9 15 2
8 15.9 HR 6 2
1 0
3.2 2
1 0
1.9 46 8
73 80.9 39 8
82 82.1
% TOTAL:
40.8 7.0 51.0 21.9
% TOTAL 35.7 7.0 57.3 21.9
% TOTAL
% TOTAL 9
1 4
12.4 6
0 4
8.7 HR 8 3
1 0
3.5 3
1 0
3.5 34 10 51 84.1 29 9
63 87.8
% TOTAL:
40.7 10.6 48.7 15.8
% TOTAL 33.0 8.7 58.3 16.1
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-66 of 2-123 Revision 0, 2020 Line 10 to the grid base. The SE sector comprises the remaining area to the east of the S line and below Indian Point. These results are summarized below in terms of number of occurrences and percentage of total possible observations:
TABLE 7 SUMMATION TRAJECTORY OCCURRENCES SOUTH OF INDIAN POINT August, 1978 Pattern 1 Pattern 2 Southwest South Southeast Southwest South Southeast Occur Occur Occur Occur Occur Occur Hour 1 232 31.8 84 11.5 25 3.4 232 31.8 84 11.5 25 3.4 Hour 2 192 26.4 51 7.0 83 11.4 148 20.3 50 6.9 108 14.8 Hour 4 128 17.6 27 3.7 133 18.3 111 15.3 29 4.0 146 20.1 Hour 6 100 13.8 10 1.4 124 17.1 86 11.9 17 2.3 130 18.0 Hour 8 67 9.3 7
1.0 90 12.5 53 7.3 15 2.1 96 13.3 JANUARY, 1979 Hour 1 154 21.4 72 10.0 271 37.6 154 21.4 72 10.0 271 37.6 Hour 2 133 18.5 41 5.7 176 24.4 100 13.9 45 6.3 207 28.8 Hour 4 67 9.3 16 2.2 92 12.8 57 7.9 14 1.9 106 14.8 Hour 6 46 6.4 8
1.1 73 10.2 39 5.4 8
1.1 82 11.5 Hour 8 34 4.8 10 1.4 51 7.1 29 4.1 9
1.3 63 8.8 The effect of the pattern change is not so much as to alter the total; rather, it is to shift the number of occurrences from the SW sector to the S and SE sectors. There are anomalies found that may be associated with recirculation.
After five miles of southward movement from Indian Point, the results seem to indicate the anomaly of surface wind impaction against the South Mountain and High Tor Ridges.
This anomaly occurred since there were no local wind measurements available to induce deflections.
Historical studies have shown such deflections do exist. The present results cannot account for terrain unless the trajectory paths are deflected by observed surface winds.
This requires a larger monitoring network, strategically placed, than was available. This need for further definition of local wind field is confirmed by the differences that appear in the results generated by Patterns 1 and 2.
At the present time, based on historical studies, Pattern 2 is probably the better representation of local trajectories for the available data.
Assuming a continuous 1 M/S wind speed (2.2 MPH), the number of occurrences in the south sector represent those parcels that have traveled with the effective speed (neglecting recirculation). Of the totals given, only four have traveled greater than ten miles for August (1); five for August (2); six for January (2); six of January (1); and three for January (2). These points would have to had passed through or over the South, High Tor and Hook Mountain Ridge lines.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-67 of 2-123 Revision 0, 2020 3.2.3 March 1980 - December 1980 3.2.3.1 General The results of the Trajectory II Study conducted by York Services Corporation for Con Edison have been recently submitted (Kaplin and Wuebber, 1981).
It was concluded from the initial trajectory study (Kaplin and Wuebber, 1980; Kaplin, 1980) that a lack of directional persistence of low speed surface winds (10M) at Indian Point and Bowline make recirculation of local air probable. There were indications of both convergence and divergence of local air streams. Objectivity created surface air parcel trajectories generated anomalies by passing over or through abrupt terrain features. The two local monitoring sites available were unable to resolve these anomalies.
In the Trajectory II Study, a supplemental network of ten surface wind monitoring stations were established for the express purpose of objectively assessing the southward movement of air parcels from Indian Point (see Figures 3 and 4). Sites were selected, specifically, in an attempt to resolve anomalous flow patterns with respect to terrain and tributary river drainage basins. A listing of sites used is shown in Table 8. A listing of valid data collected for the period is shown in Table 9.
3.2.3.2 Wind Frequency Distributions An historical evaluation of the representativeness of the data collected in 1980 was made for Indian Point and Bowline. Variations in wind frequency distributions were found to be associated with climatological variations on the synoptic-cyclonic scale.
These variations can be naturally expected between any given year or set of years. For example: Over a 20 year period (1960-1979) prior to 1980 Bridgeport, WBAS, for the month of July had an average wind directional frequency for a north wind of 6.5 +/- 2.7-percent with an absolute maximum of 12.9-percent in 1974 and an absolute minimum of 3.0-percent in 1979. In 1980, the frequency set a new low of 2.8-percent. A further extreme example was found at La Guardia WBAS. Based on an eight year average (1972-1979) the northwest wind has a frequency of 12.2 +/- 4.2-percent with minimum of 6.1-percent (1973) and a maximum of 16.5 (1974). In 1980, a new maximum of 18.2-percent was observed while in 1979, the frequency was 7.9-percent, which was the second lowest value in the period.
It was noted that the climatic variations of wind frequencies at Indian Point were generally minimal and less pronounced. This was attributed to topographic confinement.
The wind frequency data for Indian Point and Bowline for the data collection period were adjudged to be representative (Figures 6.1-6.4, Kaplin and Wuebber, 1981). It was assumed that all concurrently collected wind velocities were representative of respective monitoring sites and relationships between sites could be evaluated.
It was found that wind frequency distribution patterns in themselves were deceptive representations of the continuity of air movement in the lower Hudson River valley unless there was an understanding of the patterns of wind velocity variations on a temporal basis.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-68 of 2-123 Revision 0, 2020 TABLE 8 LOCATIONS OF STATIONS RELATIVE TO INDIAN POINT Station Distance (miles) from Indian Point Direction (degrees)
Iona Island 2.50 334 Annsville 2.20 020 Watch Hill Road 3.15 132 Jurka 6.65 122 Croton Point 6.40 155 Ossining 8.80 151 Grassy Point 3.20 191 Bowline Point 4.15 190 South Nyack 13.60 174 Piermont 15.95 173 Kingsland 13.00 163 Eastview 11.90 145 Westchester County Airport 20.00 135
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-69 of 2-123 Revision 0, 2020 TABLE 9 YORK SERVICES CORPORATION ONE RESEARCH DRIVE, STAMFORD, CT CLIENT: CONSOLIDATED EDISON OF NEW YORK VALID DATA FOR TRAJECTORY WIND SITES PERIOD OF RECORD: 1980 SITE PERCENT VALID DATA MARCH APRIL MAY JUNE JULY AUGUST SEPT OCT NOV DEC 01-Piermont 79.23 78.75 63.71 66.67 100.00 100.00 71.25 37.10 0.00 0.00 02-Ossining 98.59 100.00 100.00 100.00 100.00 99.80 99.93 96.77 100.00 100.00 03-Iona Island 96.77 53.75 85.28 69.72 53.76 95.63 100.00 99.46 100.00 82.80 04-Jurka/Grassy 78.76 55.97 0.00 0.00 0.00 0.00 0.00 81.85 100.00 84.95 05-Kingsland 87.57 94.65 17.47 59.79 98.66 100.00 100.00 100.00 74.03 93.55 06-Watch Hill 74.46 0.00 0.00 0.00 48.79 70.56 100.00 85.48 100.00 100.00 07-South Nyack 79.17 100.00 83.87 100.00 100.00 100.00 100.00 100.00 100.00 100.00 08-Annsville 100.00 100.00 90.86 100.00 77.28 100.00 71.81 98.92 100.00 100.00 09-Eastview 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 100.00 10-Croton Point 99.73 100.00 89.85 100.00 98.12 96.77 81.39 47.04 100.00 36.96 11-West Cty Apt 99.87 100.00 100.00 99.86 100.00 100.00 100.00 100.00 100.00 100.00 12-Indian Point 99.66 100.00 94.82 99.24 95.41 94.69 99.17 99.93 100.00 99.46 13-Bowline Point 72.45 99.72 98.91 85.97 92.41 98.52 96.53 96.98 96.46 86.16
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-70 of 2-123 Revision 0, 2020 3.2.3.3 Diurnal Wind Distributions The diurnal variation curves for Indian Point and Bowline for the data collection period (March through December 1980) were found to be historically representative. For selected winter and summer months, they demonstrated all the attributes of the two season characteristics (Figure 6.21-6.27, Kaplin and Wuebber, 1981).
With some variation at selected monitoring sites, it was found that the diurnal wind distributions were not only seasonally characteristic but characteristic of the monitoring site locations. They could, almost without exception, be uniquely categorized as Hudson River west bank; Hudson River east bank; or inland (Figures 6.28-6.33, Kaplin and Wuebber, 1981).
The characteristics of this uniqueness were examined by combining all appropriate sites to generate average east and west bank diurnal wind distributions (Figures 6-38-6.42, Kaplin and Wuebber, 1981). The average diurnal curves for March, June and December, 1980 are shown in Figures 13, 14, and 15. A computer check revealed that individual days at any given site could be found that had observed 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> diurnal wind variation patterns that matched their own monthly average distributions and/or the appropriate east or west bank average diurnal distribution based on the criteria 16 or more hours of fit +/- 45° (not necessarily consecutive).
While there are unique common characteristics to the diurnal wind distribution patterns in the Indian Point environs, variations in local meso-scale factors dictate that the ultimate path of an air parcel whose movement is determined by surface (10M level) wind velocities is governed by time of departure as well as point of departure. Between wind velocity monitoring sites in the region, persistent wind direction and wind speeds are not supported. This is most obvious during the summer season or at any time that the area is under the influence of a weak synoptic-cyclonic pressure gradient pattern.
Between individual monitoring sites there is apparent divergence and convergence of surface air.
3.2.3.4 Resultant and Concurrent Hourly Winds A first approach at the evaluation of southward movement of air for prolonged periods of time was made for the data collection period March 1, 1980 through December 31, 1980, by examining the frequency distribution of the 24 hour2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> resultant winds (Kaplin and Wuebber, 1981). These results are shown in Table 10 as a function of persistence category (the ratio of the resultant to arithmetic average wind speeds). At persistence levels greater than 0.9, a north wind was found in only four out of 273 possible valid cases (1.4%). The average wind speed 2.75 M/S. The high wind speeds associated with all northerly winds implies strong synoptic-cyclonic scale pressure gradient systems are the generating mechanism.
Simple liner relationships between high persistent, 24-hour resultant winds between Indian Point and Piermont (bearing 173° about 16-miles from Indian Point) showed that an average 24-hour resultant wind direction of 012 +/- 22° at Indian Point was related to an average 24-hour resultant wind at Piermont of 359 +/- 24°. At the same time, for corresponding cases, the average resultant wind speed at Indian Point was about 2.5 +/-
0.9 M/S and the concurrent average resultant wind speed at Piermont was 5.6 +/- 1.2 M/S. The angular offset implies terrain tracking and high average resultant wind speeds indicate the necessity for a strong pressure gradient field.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-71 of 2-123 Revision 0, 2020 Such replacements were also implied when concurrent hourly average wind data from the selected monitoring sites were correlated to Piermont. These results are shown in Table 11 for the available concurrent data collected during the period from March 1, 1980 through October 31, 1980. Out of 4,394 valid data hours, there were only 56 (1.3%) in which Indian Point and Piermont had concurrent winds from the north (350-011°). Almost half of these cases (26:0.59%) occurred in May, 1980. There was only one such hour out of 742 valid data hours in July, 1980. For July, in fact, for 3,355 concurrent data hours from five southern sites there was only one additional hour in which a site, South Nyack, had a north wind direction concurrent with Piermont.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-72 of 2-123 Revision 0, 2020 TABLE 10 FREQUENCY DISTRIBUTION OF 24 HOUR RESULTANT WIND DIRECTIONS INDIAN POINT (10 METER LEVEL)
Persistence Persistence Resultant
> 0.9
> 0.8 <0.9 Wind Aver. SPDS (MPH)
Aver. SPDS (MPH)
Direction No. Obs.
Result.
Mean No. Obs.
Result.
Mean No. Obs.
350-011 4
5.75 6.15 6
4.87 5.62 2
012-034 20 4.97 5.22 6
4.05 4.67 4
035-056 13 4.81 4.98 8
3.56 4.04 1
057-079 5
4.06 4.24 2
2.70 3.15 2
080-101 0
0 1
102-124 0
0 0
125-146 0
0 0
147-169 0
0 1
170-191 2
2.90 3.10 1
3.20 3.70 0
192-214 10 3.38 3.53 5
2.38 2.76 5
215-238 3
4.07 4.23 7
2.69 3.11 1
237-259 0
3 4.40 5.27 2
260-281 0
1 2.40 3.00 2
282-304 0
3 3.03 3.70 1
305-326 6
4.17 4.48 4
5.15 6.00 3
327-349 13 7.82 8.22 8
4.64 5.40 7
76 54 31 Percent:
25.94 18.43 10.58 Number of Valid 24-hour Resultants ( >17 hours): 293 Percent Valid Data: 97.39
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-73 of 2-123 Revision 0, 2020 TABLE 11
SUMMARY
OF TWO-STATION WIND CORRELATIONS PIERMONT (SITE 1) REFERENCED TO SELECTED MONITORING LOCATIONS (SITE 2)
North Wind at Piermont North Wind at Site 2 Number of Observations Resultant Wind @ Site 2 Resultant Wind @ Piermont Station North Winds Concurrent Winds Speed Speed Month (Site 2)
Total Piermont Site 2 All Directions North Direct.
(mph)
Persist.
Direct.
(mph)
Persist.
March South Nyack 588 83 33 70 10 331 3.3 0.90 025 8.5
- 0.
Kingsland 481 71 74 133 39 004 6.7 0.96 001 9.2
- 0.
Ossining 586 83 25 31 4
327 3.8 0.92 023 7.5
- 0.
Iona Island 565 76 16 65 3
327 5.0 0.73 042 9.4
- 0.
Indian Point 589 83 67 137 7
035 4.2 0.89 334 9.3
- 0.
April South Nyack 567 50 25 63 6
346 1.9 0.65 025 6.6
- 0.
Kingsland 490 39 68 145 13 008 3.2 0.79 018 8.1
- 0.
Ossining 567 50 28 45 2
316 2.6 0.85 030 8.8
- 0.
Iona Island 354 30 21 26 2
308 4.5 0.73 043 11.0
- 0.
Indian Point 567 50 58 129 6
020 2.4 0.64 340 8.5
- 0.
May South Nyack 359 46 20 33 2
327 3.7 0.84 032 6.8
- 0.
Kingsland 67 2
2 9
0 256*
2.1*
0.98*
031*
10.0*
- 1.
Ossining 474 68 37 28 4
309 6.4 0.85 036 9.9
- 0.
Iona Island 415 66 22 20 2
301 7.3 0.89 052 6.6
- 0.
Indian Point 422 50 58 91 26 350 3.5 0.79 356 10.1
- 0.
June South Nyack 480 17 19 57 2
332 4.0 0.92 036 8.2
- 0.
Kingsland 284 5
2 30 1
301*
5.6*
0.95*
031*
5.4*
- 0.
Ossining 480 17 16 41 0
318 7.3 0.90 046 6.7
- 0.
Iona Island 368 12 8
16 0
301 8.5 0.88 062*
9.1*
- 0.
Indian Point 475 17 28 80 4
326 3.1 0.73 006 5.6
- 0.
July South Nyack 744 10 25 114 1
332 2.7 0.92 041 7.9
- 0.
Kingsland 724 10 25 98 0
337 2.3 0.55 052 5.7
- 0.
Ossining 744 10 37 66 0
326 4.5 0.79 047 6.8
- 0.
Iona Island 401 5
9 45 0
302*
10.0*
0.95*
054*
5.7*
- 0.
Indian Point 742 10 35 108 1
007 2.3 0.64 358 4.7
- 0.
- Less than 10 valid data points
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-74 of 2-123 Revision 0, 2020 TABLE 11 (Contd)
SUMMARY
OF TWO-STATION WIND CORRELATIONS PIERMONT (SITE 1) REFERENCED TO SELECTED MONITORING LOCATIONS (SITE 2)
North Wind at Piermont North Wind at Site 2 Number of Observations Resultant Wind @ Site 2 Resultant Wind @ Piermont Station North Winds Concurrent Winds Speed Speed Month (Site 2)
Total Piermont Site 2 All Directions North Direct.
(mph)
Persist.
Direct.
(mph)
Persist.
Aug.
South Nyack 744 24 44 95 1
334 3.0 0.75 058 11.9 0.95 Kingsland 744 24 52 93 1
313 4.8 0.74 054 11.7 0.92 Ossining 741 24 58 96 2
336 6.9 0.84 047 10.5 0.87 Iona Island 679 24 15 80 0
308 4.9 0.66 036 9.8 0.80 Indian Point 719 24 32 139 3
037 2.5 0.70 332 5.2 0.73 Sept.
South Nyack 513 37 36 63 10 348 2.5 0.88 018 12.6 0.91 Kingsland 513 37 22 42 3
345 4.6 0.79 026 9.6 0.90 Ossining 512 36 36 87 9
354 5.0 0.86 010 9.4 0.84 Iona Island 513 37 10 34 3
322 4.8 0.76 024 11.7 0.91 Indian Point 501 37 38 102 4
031 3.4 0.83 339 7.2 0.85 Oct.
South Nyack 379 24 28 83 5
335 2.8 0.91 019 10.7 0.92 Kingsland 379 24 25 64 5
018 3.0 0.73 019 11.4 0.96 Ossining 379 24 31 69 4
007 4.0 0.85 016 11.8 0.95 Iona Island 379 24 12 38 3
291 2.8 0.77 016 12.9 0.99 Indian Point 379 24 24 89 5
031 2.9 0.95 009 7.5 0.86 Table 11 can be summarized in terms of the valid wind direction data from the five designated sites concurrent with wind directions at Piermont (Note: The data from these sites should not be presumed concurrent with each other simultaneously).
This summary is shown in Table 12.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-75 of 2-123 Revision 0, 2020 TABLE 12 CONCURRENCE OF TWO-STATION WIND DIRECTIONS (Relative to Piermont) 5 Site Total
% Valid Percent (Concurrent Data Basis)
Concurrent Data 6 Site Basis All Directions North Wind March 2809 62.93 15.52 2.24 April 2545 58.91 16.03 1.14 May 1737 38.91 10.42 1.96 June 2087 48.31 10.73 0.34 July 3355 75.16 12.85 0.06 August 3627 81.25 13.87 0.19 September 2552 59.07 12.85 1.14 October 1895 42.45 18.10 1.16 Since these data are derived from hourly average wind directions, it is again shown that there is little likelihood of sustaining south bound movement of air from Indian Point beyond 15-miles.
3.2.3.5 Summary-Trajectory II Study A modified version of the generic model TRAJECTORY (Kaplin and Wuebber, 1980) was used as a basis of a study, which involved the use of concurrent hourly average wind data from a network of 13-14 monitoring stations within 20-miles of Indian Point. All but four sites were located on the Hudson River shorelines. Only two sites were used to the north of Indian Point. As with the original study (Kaplin and Wuebber, 1980),
emphasis was on the objective creation of the trajectories of air parcels originating hourly at Indian Point with a speed and direction equal to the average wind at the 10 meter level of Indian Point 122 Meter Meteorological Tower.
In the Trajectory II Study (Kaplin and Wuebber, 1981), each parcel of air was tracked for eight consecutive hours after its movement was initiated as dictated by two factors:
The movement time interval and the wind velocity at the coordinate end point of the parcel at the end of movement time interval. As in the earlier study a 21 by 21-mile grid pattern of one mile squares was used to generate tabulations of the trajectory segment end-points. While the tabulations assumed each point to be located in the center of each square, the actual coordinates within the squares were used as a starting point for the next hourly trajectory segment. Subsequent movement of a parcel from a given set of coordinates was determined by the appropriate average hourly wind velocity assigned to grid square as determined by a zone of influence file. While trajectories were objectively created, the zone of influence file required the subjective assignment of each available wind velocity monitoring site to specific grid squares. The wind velocity for any given hour within these assigned grid squares would be the same as that of the specified control monitoring site.
Influence assignments were based on assessments of local wind patterns (historical and present) with some consideration for obvious meso-scale modification factors:
topographic channeling, drainage flow patterns, thermally induced flow patterns, etc.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-76 of 2-123 Revision 0, 2020 For the purpose of the study, all movements of parcels past the grid boundaries were assumed to continue their movements under the influence of the site whose wind was being used at the time that a boundary was crossed.
When only a few wind monitoring sites are available to cover a large area, movement controlled solely by a single sites non-variant hourly average wind was not a critical factor. As the number of monitoring sites increased and zones of influence became smaller, discrete movement based on a single wind in a given hour increment would allow a parcel to move through a zone of influence without modification of its controlling wind, which could be substantially different in direction and speed than that associated with the by-passed zone. In the TRAJ3 model, as used in this study, parcel end point coordinates at the end of each hour, which had been previously determined by the non-variant wind at the parcel source at the beginning of each hour, were the resultant of 30 discrete movements (two minute intervals) within the hour interval. On this basis, a wind speed of 30 mph was required in order for a parcel to travel with a non-variant wind for more than one mile. A discrete wind velocity was reassigned to a parcel according to its coordinates (zone of influence) at the end of each two minute intervals.
In effect, a parcel could, in extreme, alter its direction and speed 30 times in a given hour and not apparently move at all if it were trying to move from one zone of influence to another at a boundary line between zones and the wind in the two zones were in opposition. Such apparent anomalies were found as a matter of routine.
Figure 16 shows the grid system that was used in the Trajectory 2 Study, Indian Point was located at coordinates 7,17. In the development of the trajectories recirculation was allowed. This is a parcel could leave the grid boundaries and be brought back onto the grid at a later time if dictated by a change in the wind at the monitoring site controlling its movement.
In the first hour of movement for the ten months of data, only 390 parcels out of 7,344 (5.3) left the grid system and did not return. Of these 345 (4.7%) were crossings of the northern grid boundary, 40 (0.5%) were crossings of the western grid boundary and 5 (0.1%) were crossings of the southern grid boundary. There were no crossings of the eastern grid boundary. Of the five points crossing the southern boundary, all occurred in December, 1980. To cross the southern boundary a minimum speed of 7.6 M/S (17 mph) was required.
During the ten months (206 days) of record there were only 35 days (11.4%) in which there are no rotation and/or recirculation (flow reversal) characteristics in at least one of the 24 trajectories created daily. This does not take into account any trajectories that may have experienced reversals wholly outside of the grid area.
If flow reversals and rotational trajectories were due solely to synoptic scale meteorological patterns, then randomness would be expected in the starting time occurrence frequency as a diurnal function. The actual pattern observed for those eight hour trajectories, which contained at least one on grid or on-off-on grid flow reversal is shown in Table 13. These results include those reversals of synoptic origin and can be interpreted as consistent with the local average diurnal wind patterns induced by meso-scale phenomena when the following factors are taken into account:
Nocturnal flow patterns generally north to south with minimal with speeds Afternoon flow patterns generally south to north with maximum wind speeds
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-77 of 2-123 Revision 0, 2020 Summaries of the trajectory end-point counts and percentages are shown on a monthly basis in Tables 14 and 15 for selected time increments up to the complete eight hour trajectory. The idealized valley is shown in Figure 16. It is noted that the idealized valley contains 64 out of 441 (14.5%) possible grid box end-point coordinates: ten grid boxes are north of Indian Point; and 54 are on a line with Indian Point and south. With respect to total grid, 84 boxes are to the north and 357 are to the south.
The effect of dominant meso-scale factors are readily discernible in the results.
Differences in north and south boundary crossings of trajectory points can be related to the normal seasonal distribution of local wind velocities as well as their diurnal distribution patterns. During the summer season it would take up to six hours of persistent north sector winds from Indian Point to Piermont to generate a south boundary crossing. Such a persistent diurnal time span is improbable. After eight hours, only 6.7 percent of all possible trajectory end-points for all time intervals in July 1980 (5,924 possible) were found to cross the southern boundary (a distance of 17-miles from Indian Point). The highest crossing percentage, 30.7 percent of 5,924 possible, occurred in December, 1980.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-78 of 2-123 Revision 0, 2020 TABLE 13 Diurnal Distribution of Occurrences of Eight-Hour Trajectories with On Grid Reversals Starting End Number of Trajectory with Flow Reversals Hour Hour Mar Apr May June July Aug Sept Oct Nov Dec Total 0100 0900 7
9 13 13 14 9
13 7
7 10 102 0200 1000 11 9
15 9
11 10 15 10 9
6 105 0300 1100 9
11 12 15 14 14 12 12 8
8 115 0400 1200 12 11 18 14 17 13 11 12 6
10 124 0500 1300 10 11 16 17 21 13 14 11 4
9 126 0600 1400 9
11 10 13 19 13 14 11 7
11 118 0700 1500 10 8
9 10 10 12 12 7
9 9
96 0800 1600 6
7 5
10 9
10 14 7
10 7
85 0900 1700 6
10 6
8 11 6
10 4
7 8
76 1000 1800 5
7 10 11 7
8 9
4 9
7 77 1100 1900 6
8 4
4 9
7 9
6 4
5 62 1200 2000 2
8 2
4 10 8
10 5
6 4
59 1300 2100 2
8 4
5 6
5 8
4 5
6 53 1400 2200 3
4 5
5 11 5
7 6
5 6
57 1500 2300 2
7 6
4 12 11 8
6 8
6 70 1600 2400 5
5 7
6 12 11 8
6 10 7
77 1700 0100 7
6 10 9
17 12 9
6 8
8 92 1800 0200 10 7
12 8
16 10 9
9 7
9 97 1900 0300 10 3
14 11 14 8
7 6
7 10 90 2000 0400 12 9
14 7
15 8
6 6
6 8
91 2100 0500 12 8
13 5
8 8
7 7
9 8
85 2200 0600 15 9
12 10 8
6 7
8 6
8 89 2300 0700 10 12 13 8
10 9
8 9
5 9
93 2400 0800 7
5 12 10 13 11 9
8 5
11 91 TOTAL 188 193 242 216 294 227 236 177 167 190 2130 TOTAL POSSIBLE 736 712 736 712 736 736 712 736 712 736 7264 OCCURRENCE (%)
25.5 27.1 32.9 30.3 39.9 30.8 33.1 24.0 23.5 25.8 29.3
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-79 of 2-123 Revision 0, 2020 TABLE 14
SUMMARY
OF TRAJECTORY END-POINT COUNTS March April May June July August Sept Oct Nov Dec Number of Hours/Month 744 720 744 720 744 744 720 744 720 744 Total Number of End-Points 5924 5732 5924 5732 5924 5924 5732 5924 5732 5924 Elapsed Time Number of End-Points 2 Hours -
Number of Trajectories 742 718 742 718 742 742 718 742 718 742 Within Grid 490 440 577 559 593 599 498 595 538 513 In Valley (North of Indian Point) 41 29 49 65 51 57 36 39 30 44 In Valley (Indian Point and South) 95 94 150 148 305 185 178 204 139 123 Percent Grid Points in Valley 28.3 28.0 34.5 38.1 60.0 40.4 43.0 40.8 31.4 32.6 4 Hours -
Number of Trajectories 740 716 740 716 740 740 716 740 716 740 Within Grid 275 244 356 355 433 361 328 371 285 297 In Valley (North of Indian Point) 20 8
17 34 28 26 15 22 13 17 In Valley (Indian Point and South) 43 59 118 106 139 146 109 156 97 78 Percent Grid Points in Valley 22.9 27.5 37.9 39.4 38.6 47.6 37.8 48.0 38.6 32.0 6 Hours -
Number of Trajectories 738 714 738 714 738 738 714 738 714 738 Within Grid 173 183 257 257 342 277 250 255 175 213 In Valley (North of Indian Point) 8 5
9 13 20 9
6 16 7
11 In Valley (Indian Point and South) 18 42 93 91 105 119 80 106 63 46 Percent Grid Points in Valley 15.0 25.7 39.7 40.5 36.5 46.2 34.4 47.8 40.0 26.8 8 Hours -
Number of Trajectories 736 712 736 712 736 736 712 736 712 736 Within Grid 121 135 190 194 276 226 199 188 130 160 In Valley (North of Indian Point) 9 5
6 9
9 3
5 4
6 11 In Valley (Indian Pint and South) 11 25 73 61 91 87 51 70 47 38 Percent Grid Points in Valley 16.5 22.2 41.6 36.1 36.2 39.8 28.1 39.4 40.8 30.6 Total Past South Boundary*
1643 958 1048 636 399 708 657 926 1706 1821 Percent Past South Boundary 27.7 16.7 17.7 11.1 6.7 12.0 15.0 15.6 29.8 30.7 Total Past North Boundary*
1013 1676 937 Percent Past North Boundary 17.1 28.3 15.8
- This count includes all end-points for all time intervals.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-80 of 2-123 Revision 0, 2020 TABLE 15
SUMMARY
OF TRAJECTORY END-POINTS (Percent) 2 Hours 4 Hours 6 Hours 8 Hours Total
% On
% In Total
% On
% In Total
% On
% In Total
% On
% In Month Traj.
Grid Valley Traj.
Grid Valley Traj.
Grid Valley Traj.
Grid Valley March 742 66.0 18.3 740 37.2 8.5 738 23.4 3.5 736 16.4 2.7 April 718 61.3 17.1 716 34.1 9.4 714 25.6 6.6 712 19.0 4.2 May 742 77.8 26.8 740 48.1 18.2 738 34.8 13.8 736 25.8 10.7 June 718 77.7 29.7 716 49.6 19.5 714 36.0 14.6 712 27.2 9.8 July 742 79.9 48.0 740 58.5 22.5 738 46.3 16.9 736 37.5 13.6 August 742 80.7 32.6 740 48.8 23.2 738 37.5 17.3 736 30.7 12.2 September 718 69.4 29.8 716 45.8 17.3 714 35.0 12.0 712 27.9 7.9 October 742 80.2 32.7 740 50.1 24.1 738 34.6 16.5 736 25.5 10.1 November 718 74.9 23.5 716 39.8 15.4 714 24.5 9.8 712 18.3 7.4 December 742 69.1 22.5 740 40.1 12.8 738 28.9 7.7 736 21.7 6.7 Average 73.7 28.1 45.2 17.1 32.7 11.9 25.0 8.5 Standard Deviation 6.5 8.4 7.0 5.3 6.7 4.6 8.1 3.3
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-81 of 2-123 Revision 0, 2020 In any given month of the ten that were investigated and out of the 7,242 complete eight hour trajectories that were generated, there were a number of basic pattern types.
There were those whose sequence of temporal end-points exhibited basic straight line tendencies. These were generally associated with high wind speeds. There were those whose sequence of end-points that rotated in a more or less smooth pattern but they were not usually associated with a meso-scale diurnal rotation or terrain induced deflections. In addition, there were those that exhibited characteristics of recirculation and those in which there were sharp reversals. These were induced by wind velocity changes of synoptic scale origin and/or most frequently they appeared in those trajectories, which included the morning or evening transitional periods, meso-scale induced. In the latter cases, of rotation, recirculation and reversals, the sequences may occur wholly on the grid or on-off-on on the grid.
Examination of details of specific trajectories and concurrent opposing winds suggests that three block regions can be projected in the lower Hudson Valley within the grid system. These regions are:
Peekskill Bay Haverstraw Bay Tappan Zee The reality of the zones of divergence and convergence on a concurrent wind basis were premised on the continuity of air flow movements locally and for air streams that were projected to cross the Hudson River. This latter feature was not uniquely demonstrated with respect to surface (10 meter) level wind velocities. If some local wind patterns were induced by thermal differentials between land and water during periods of weak geostrophic pressure gradients in accordance with sea breeze concepts: during the day air will move from cool water to warm land with return flow aloft; at night, a reverse flow pattern may develop. If this occurred on opposite shorelines of a wide river, concurrently, then there should be vertical motions induced by convergence and divergence in the mid river area or a region of air flow directionally independent of the shoreline circulations. The light wind speeds that were normally found at Croton Point during periods of weak geostrophic flow may result from its proximity to a mid river transition zone. (During periods of strong northwesterly gradients Croton Point had a high frequency of west to west northwest winds implying a cross river flow parallel to South Mountains.)
In addition to the land-water effects in so far as they generate local on-shore and off-shore winds, the effect of nocturnal drainage winds should be considered. The Kingsland Park site was one example. A zone of convergence frequently develops at night between that site and Ossining. This was also apparent from the average diurnal monthly diurnal wind distributions. If only drainage winds are considered, from Figure 4, Ossining would reflect drainage from the Croton River and/or a secondary local river both of which would generate air movements from the north-northeast. Kingsland Park is, however, at the outfall to Gory Brook, while this drains from the north-northeast, it hooks in its final section and outfalls into the Hudson from the southeast. There were no measurements available upon which to alter these directions after the air streams flow into the Hudson River itself. For the objective creation of eight hour trajectories, these winds were presumed to extend into the Hudson River and generate local blocks on a concurrent hourly basis.
The dominance of mesoscale flow factors on surface winds in this study have been demonstrated over and over since local meteorological data have been collected. The
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-82 of 2-123 Revision 0, 2020 surface wind data sets used for this study are from the most extensive network of concurrent monitoring stations that have ever been deliberately located in the region.
These data have been evaluated by many of the routine methodologies common to earlier local studies. All of the data sets were found to exhibit characteristics of complex meso-scale flow fields distortions. The east shore stations were found to share some common characteristics on a daily basis and the same was true for the west shore stations. These characteristics were frequently in opposition to each other. At the same time inland stations had characteristics that were entirely different from either the east or the west shore stations.
The creation and interpretation of eight hour trajectories from these data sets could not be truly separated from the concurrent flow fields on an hourly basis. The eight hour trajectories were a result of the constantly changing concurrent flow field. They were a distinct function of movement interval when based on hourly average wind velocities; and therefore, it may be presumed that in a dynamic flow field they would be equally sensitive to the wind averaging interval itself. As noted earlier, this study did not account for vertical air movement, the trajectories were therefore extremely sensitive to one crucial factor - the assumption of continuity of air movement across the Hudson River without midstream directional distortions.
The results of this study indicated that continued southward movement of air parcels in the Hudson River Valley could not generally be sustained past Piermont, if, in accordance with the data evaluated, Permonts winds are assumed to be representative of the full width of Hudson River.
3.2.4 January 1, 1979 Through December 31, 1980 3.2.4.1 Data Analyses In the previous sections, with reference to the Trajectory I and Trajectory II studies, portions of 1979 and 1980 data from the Indian Point Meteorological Tower were analyzed and evaluated with reference to the studies that were in progress. Some of these analyses included references to historical data. In both of these studies it was concluded that the meteorological data being obtained at Indian Point were representative of that site and that any observed variations in wind frequency distributions and diurnal variations were assignable to transient climatological deviations from the norm on, at least, the synoptic-cyclonic scale of meteorological events. There was no indication that any changes could be attributed to local physical or dynamic modification, and/or in monitoring equipment and analyses techniques, which could introduce permanent data bias.
To maximize the recent data analyses, all of 1979 and 1980 have been evaluated and compared to historical data as available. The amount of valid data for these years has been previously tabulated in Table 2.
3.2.4.2 Wind Frequency Distributions For Climatological perspective, historical comparisons have been made for selected months: March, July and December, between the wind direction, wind frequency distributions at the 10 meter level of the 122 Meter Indian Point Tower and climatological data available from Bridgeport, Connecticut and La Guardia Airport in New York City. These latter sites are within the synoptic-cyclonic scale range of Indian Point.
The distributions are shown in Table 16. With respect to March and July, climatological
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-83 of 2-123 Revision 0, 2020 frequency extremes are noted on a nine year basis for La Guardia and a 21 year basis for Bridgeport.
The fluctuations of the frequency distributions and the extremes can be associated with the frequency distribution fluctuations at Indian Point when consideration is given to the fact that winds at Indian Point are channeled by the west bank terrain.
Tables 17 and 18 give the percent frequency distribution of wind direction at Indian Point at the on seasonal basis for the 10 meter and 122 meter sensor levels. These data are compared to comparable results for 1973-1974 (Kaplin, et. al.1974, Appendix D).
In the summer season (Table 17), there is a frequency shift at the 10 meter level from SW and SSW in 1974 to SSW and S in the 1979-1980 period. This shift (with a directional bias) can be related to a similar shifting pattern at Bridgeport and La Guardia as found for July in Table 15. This shift tendency is also found implied at the 122 meter level. There is no reason to expect that these pattern changes are permanent.
For the winter season (Table 18) there is a recent bias of wind frequencies to the NNW ad N sectors at both the 10 meter and 122 meter levels at Indian Point. These shifts have their counterpart in the March and December distributions of Table 16.
It is concluded that the wind velocity data that has been collected in recent years is consistent with the data base for FSAR 2 at all measurement levels when normal climatological variations are considered.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-84 of 2-123 Revision 0, 2020 TABLE 16A HISTORICAL COMPARISONS OF WIND FREQUENCY DISTRIBUTIONS MARCH Indian Point LaGuardia Bridgeport 1974 1979 1980 1974 1979 1980 1974 1979 1980 N
.120
.078
.125
.044
.137*
.085
.044
.083
.077 NNE
.108
.093
.104
.032
.038
.016**
.012
.020
.040 NE
.115
.174
.173
.109
.105
.085
.097
.031
.052 ENE
.019
.039
.057
.085
.032
.061
.069
.043
.097 E
.008
.011
.030
.000**
.013
.024
.020##
.095
.061 ESE
.004
.009
.007
.008**
.013
.008**
.008
.018
.031 SE
.011
.004
.011
.008**
.023
.032
.016
.035#
.004##
.027
.014
.016
.040
.044*
.032
.012
.031#
.016 S
.057
.094
.085
.085
.199*
.145
.036
.082#
.069 SSW
.051
.133
.091
.036
.035
.057
.040
.051
.040 SW
.045
.065
.046
.052
.018
.024
.085
.057
.069 WSW
.020
.042
.024
.028
.024
.028
.057
.035
.032 W
.036
.049
.039
.089
.069
.048
.113
.065
.113 WNW
.076
.047
.024
.137
.097
.077
.145
.077
.101 NW
.124
.065
.034
.165
.079
.182*
.133
.097
.137 NNW
.129
.085
.134
.081
.066
.081
.093
.134
.048 CALM
.000
.000
.000
.000
.008
.016
.020
.047#
.012
- 9 Year High (1972-1980)
- 9 Year Low (1972-1980)
- 21 Year Low (1960-1980)
- 21 Year High (1960-1980)
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-85 of 2-123 Revision 0, 2020 TABLE 16B HISTORICAL COMPARISONS OF WIND FREQUENCY DISTRIBUTIONS JULY Indian Point LaGuardia Bridgeport 1974 1979 1980 1974 1979 1980 1974 1979 1980 N
.034
.066
.047
.093*
.036
.044
.129#
.030
.028##
NNE
.141
.112
.111
.032
.035
.040
.057
.012##
.016 NE
.148
.104
.158
.057
.059
.052
.028
.015
.012##
ENE
.054
.085
.073
.048
.055
.040##
.020
.028
.032 E
.026
.044
.045
.020
.013
.016
.069
.082
.057 ESE
.011
.019
.022
.012
.013
.008
.016
.054
.024 SE
.020
.013
.022
.044*
.031
.032
.048
.020
.016 SSE
.024
.028
.026
.016**
.032
.040
.020
.022
.020 S
.053
.079
.085
.081**
.184
.161
.073
.102
.129 SSW
.110
.212
.123
.069
.085
.073
.052##
.079
.113 SW
.129
.097
.094
.061**
.095
.133*
.085
.157
.125 WSW
.044
.028
.050
.081
.063
.040**
.154
.114
.109 W
.047
.038
.061
.149*
.073
.073
.145#
.105
.117 WNW
.043
.024
.031
.089
.063
.081
.048
.057
.052 NW
.034
.026
.024
.073
.067
.093
.004##
.069
.069 NNW
.015
.015
.031
.057
.043
.052
.048
.026
.069 CALM
.000
.000
.000
.020
.051
.020
.004
.030
.012
- 9 Year High (1972-1980)
- 9 Year Low (1972-1980)
- 21 Year High (1960-1980)
- 21 Year Low (1960-1980)
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-86 of 2-123 Revision 0, 2020 TABLE 16C HISTORICAL COMPARISONS OF WIND FREQUENCY DISTRIBUTIONS DECEMBER Indian Point LaGuardia Bridgeport 1973 1979 1980 1973 1979 1980 1973 1979 1980 N
.068
.101
.082
.081
.044
.093
.101
.058
.048 NNE
.172
.071
.148
.077
.016
.044
.048
.019
.057 NE
.162
.067
.124
.081
.046
.065
.097
.030
.040 ENE
.041
.023
.061
.040
.046
.044
.044
.031
.020 E
.015
.018
.023
.020
.013
.008
.024
.035
.012 ESE
.004
.004
.011
.016
.009
.004
.016
.013
.000 SE
.004
.008
.016
.024
.011
.000
.024
.015
.004 SSE
.015
.030
.023
.040
.008
.004
.024
.012
.024 S
.033
.100
.070
.093
.047
.056
.044
.023
.016 SSW
.048
.091
.081
.040
.058
.056
.048
.020
.024 SW
.049
.042
.057
.061
.122
.081
.048
.040
.069 WSW
.019
.042
.024
.044
.071
.044
.028
.093
.085 W
.026
.108
.031
.089
.206
.081
.141
.233
.157 WNW
.044
.094
.057
.149
.144
.121
.141
.238
.157 NW
.126
.120
.070
.069
.078
.157
.101
.066
.153 NNW
.074
.062
.114
.069
.059
.133
.044
.036
.097 CALM
.016
.000
.000
.008
.022
.008
.024
.038
.036
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-87 of 2-123 Revision 0, 2020 TABLE 17 COMPARISON OF PERCENT WIND FREQUENCY DISTRIBUTIONS - SUMMER Wind 10 Meter Level 122 Meter Level Direction 1974 1979 1980 1979-80 1974 1979 1980 1979-80 N
3.66 5.53 7.15 6.34 6.54 7.25 8.19 7.72 NNE 10.71 10.27 10.07 10.17 10.67 11.22 10.27 10.74 NE 15.89 12.58 13.68 13.13 6.40 4.85 5.31 5.08 ENE 6.20 7.46 7.78 7.62 2.41 1.88 2.26 2.07 E
2.85 2.68 3.27 2.97 1.83 1.88 1.60 1.74 ESE 1.59 1.59 1.97 1.78 1.66 1.00 1.28 1.14 SE 2.20 1.31 1.77 1.54 2.91 1.61 1.83 1.72 SSE 2.85 2.52 2.09 2.30 2.88 2.40 2.86 2.63 S
8.47 13.28 9.05 11.17 13.04 18.49 14.20 16.36 SSW 11.86 17.39 12.75 15.07 9.82 12.74 9.95 11.35 SW 12.23 9.14 8.17 8.65 10.64 10.22 8.32 9.28 WSW 3.63 3.26 4.08 3.67 5.56 5.14 5.21 5.18 W
3.08 4.28 4.95 4.62 4.44 4.12 5.24 4.68 WNW 2.61 2.74 3.88 3.31 4.17 3.85 4.37 4.11 NW 3.19 2.43 3.65 3.04 5.05 6.84 7.71 7.27 NNW 2.41 2.77 3.59 3.18 3.79 5.71 8.28 6.99 VAR.
6.51 0.00 0.00 0.00 1.56 0.00 0.00 0.00 CALM 0.07 0.00 0.00 0.00 0.14 0.00 0.00 0.00 MISS.
0.03 0.77 2.09 1.43 6.50 0.79 3.13 1.96 NO VALID HOURS 2951 4411 4407 8818 2952 4413 4373 8786
% HRS IN DISTR 100.
99.9 99.8 99.8 100.
99.9 99.0 99.5
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-88 of 2-123 Revision 0, 2020 TABLE 18 COMPARISON OF PERCENT WIND FREQUENCY DISTRIBUTIONS - WINTER Wind 10 Meter Level 122 Meter Level Direction 1974 1979 1980 1979-80 1974 1979 1980 1979-80 N
7.19 10.73 11.90 11.32 7.23 11.15 10.97 11.06 NNE 13.67 10.34 10.05 10.20 13.67 13.22 14.33 13.78 NE 12.22 11.45 15.11 13.29 5.63 4.79 4.90 4.85 ENE 4.75 5.90 6.30 6.10 1.93 1.80 1.79 1.79 E
1.59 2.86 3.02 2.94 1.60 1.45 1.79 1.62 ESE 0.95 0.71 0.85 0.78 1.16 0.92 1.65 1.29 SE 0.99 0.67 1.26 0.96 1.36 1.75 1.44 1.60 SSE 1.81 1.98 1.49 1.73 1.79 1.82 1.76 1.79 S
6.44 6.50 5.63 6.06 8.67 10.57 8.26 9.41 SSW 7.39 8.11 7.65 7.88 8.25 8.64 8.04 8.34 SW 5.76 6.24 5.72 5.98 9.36 5.87 5.59 5.73 WSW 2.58 4.31 3.04 3.67 3.51 3.18 3.37 3.27 W
3.32 4.77 4.01 4.39 2.94 3.78 4.14 3.96 WNW 5.42 5.90 4.62 5.26 5.08 6.24 5.24 5.74 NW 11.88 9.63 7.10 8.36 14.01 14.56 13.46 14.01 NNW 8.80 8.80 12.07 10.44 10.42 10.27 13.28 11.78 VAR.
4.23 0.00 0.00 0.00 1.18 0.00 0.00 0.00 CALM 0.66 0.00 0.00 0.00 0.04 0.00 0.00 0.00 MISS.
2.80 1.11 0.18 0.64 5.50 0.00 0.00 0.00 NO VALID HOURS 4967 4341 4368 8709 4924 4342 4368 8710
% HRS IN DISTR 97.6 99.9 100.
100.
96.8 100.0 100.
100.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-89 of 2-123 Revision 0, 2020 3.2.4.3 Diurnal Wind Direction Distributions Seasonal diurnal distributions of the resultant wind directions for the combined 1979-1980 data period are shown in comparison to the 1973-1974 data collection period in Table 19 and in Figures 17 and 18.
The diurnal patterns with the exception of the summer season at the 122 meter level from the 2300 to 0900 are nearly identical for the 1979-80 data set and the historical 1973-74 data set. The deviation of the 122 meter level during the nocturnal hours is also consistent when considered with respect to the summer wind frequency shift at the 122 meter level to a sharply defined south wind maximum.
It is concluded on the basis of the diurnal wind distributions that the patterns at all levels are consistent with the data base for FSAR 2 at all measurement levels with consideration for normal climatological variations.
3.2.4.4 Wind Speed Distributions All variable valid wind speeds at the 10 meter and 122 meter levels have been evaluated on a seasonal basis to determine their diurnal characteristics and the cumulative probability distributions. The results of these analyses are shown in Tables 20 and 21 for the summer season and Tables 22 and 23 for the winter season. For visual comparison, the diurnal variability is shown in Figure 19. The probability distributions are shown in Figure 20. In this latter Figure, the annual cumulative probabilities have been included. These curves were generated by combining the cumulative points in Tables 20-23.
The maximum average diurnal wind speeds from this data set can be compared with those of the 1973-1974 season as shown below in Table 24. There are no significant differences.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-90 of 2-123 Revision 0, 2020 TABLE 19 COMPARISON OF DIURNAL RESULTANT WIND DIRECTIONS 10 Meter Level 122 Meter Level Summer Winter Summer Winter Time 1974 1979-80 1973-74 1979-80 1974 1979-80 1973-74 1979-80 0100 051 034 357 359 351 300 327 329 0200 054 036 358 002 008 313 328 333 0300 050 036 359 003 007 321 329 334 0400 042 043 360 004 355 325 334 335 0500 048 048 001 003 004 327 335 335 0600 050 041 000 007 007 331 336 337 0700 042 040 001 007 011 338 339 338 0800 017 023 357 004 012 341 340 338 0900 337 348 352 356 350 334 337 339 1000 293 302 343 351 317 312 336 336 1100 258 269 335 344 260 279 325 331 1200 246 259 329 336 241 272 320 325 1300 246 247 327 336 248 261 319 321 1400 246 249 323 333 246 260 316 316 1500 233 246 322 332 233 251 313 316 1600 228 244 316 336 221 245 306 315 1700 230 233 321 337 223 239 307 312 1800 226 237 327 340 222 239 303 313 1900 232 245 330 345 233 239 308 317 2000 290 346 340 348 248 250 313 320 2100 049 033 345 355 259 263 315 325 2200 049 018 347 358 277 276 319 329 2300 055 033 351 358 297 282 321 331 2400 045 037 354 360 317 287 321 330
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-91 of 2-123 Revision 0, 2020 Job Number: 01-4122-00 TABLE 20 YORK RESEARCH CORPORATION ONE RESEARCH DRIVE, STAMFORD, CONNECTICUT 06906 CLIENT: CON EDISON CO. OF NY SITE: INDIAN POINT (10M)
PARAMETER: WIND SPEED (SUMMER SEASON)
UNITS: MPH DIURNAL ANALYSIS MAY 1, 79,80 - OCT. 31, 79,80 OBSERV PARAM AVG PARAM STD DEV MAX VALUE RANGE VALID PTS 1
2.775 1.643 10.500 10.000 362 2
2.748 1.634 9.000 8.500 362 3
2.780 1.643 10.000 9.500 362 4
2.805 1.713 10.000 9.400 362 5
2.748 1.615 9.500 8.900 359 6
2.813 1.790 10.000 9.500 358 7
2.936 1.867 13.000 12.500 358 8
3.103 1.806 12.000 11.400 363 9
3.323 1.899 10.500 9.900 363 10 3.481 1.663 10.000 9.400 361 11 3.809 1.712 10.500 9.900 362 12 3.969 1.618 10.000 9.400 363 13 4.133 1.801 14.000 13.400 363 14 4.104 1.825 12.000 11.000 362 15 4.019 1.833 12.500 11.500 361 16 3.825 1.804 13.000 12.400 359 17 3.562 1.759 12.000 11.400 360 18 3.076 1.641 9.000 8.500 361 19 2.669 1.609 12.000 11.500 362 20 2.593 1.634 10.000 9.500 361 21 2.706 1.763 12.000 11.500 361 22 2.702 1.752 10.000 9.500 361 23 2.710 1.744 10.000 9.500 361 24 2.694 1.684 10.000 9.500 362 TOTAL 3.171 1.802 14.000 13.500 8669 CUMULATIVE PROBABILITY DISTRIBUTION MAY 1, 79, 80 - OCT 31, 79, 80 CATEGORY OP. LIMIT CATEGORY POINTS CATEGORY PERCENT CUMULATIVE POINTS
< LIMIT CUMULATIVE PERCENT
< LIMIT 0.500 39 0.4 39 0.450 1.000 1177 13.6 1216 14.025 2.000 1996 23.0 3212 37.047 3.000 1977 22.8 5189 59.850 5.000 2474 28.5 7663 88.385 7.000 772 8.9 8435 97.290 9.000 181 2.1 8616 99.377 12.000 48 0.6 8664 99.931 16.000 5
0.1 8669 99.988 23.000 0
0.0 8669 99.988 30.000 0
0.0 8669 99.988 40.000 0
0.0 8669 99.988 50.000 0
0.0 8669 99.988 70.000 0
0.0 8669 99.988 NUMBER OF VALID DATA POINTS = 8669 NUMBER OF MISSING DATA POINTS = 163 REPRESENTING 98.2-PERCENT VALID DATA
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-92 of 2-123 Revision 0, 2020 Job Number: 01-4122-00 TABLE 21 YORK RESEARCH CORPORATION ONE RESEARCH DRIVE, STAMFORD, CONNECTICUT 06906 CLIENT: CON EDISON CO. OF NY SITE: INDIAN POINT (122M)
PARAMETER: WIND SPEED (SUMMER SEASON)
UNITS: MPH DIURNAL ANALYSIS MAY 1, 79,80 - OCT. 31, 79,80 OBSERV PARAM AVG PARAM STD DEV MAX VALUE RANGE VALID PTS 1
7.821 5.161 30.000 29.500 357 2
7.595 5.070 24.000 23.500 356 3
7.581 5.153 26.000 25.400 355 4
7.413 5.097 27.000 26.500 356 5
7.233 5.043 32.000 31.400 353 6
7.436 5.383 35.000 34.500 354 7
7.499 5.616 47.000 48.400 355 8
7.332 5.442 47.000 48.400 359 9
7.717 5.320 38.000 37.400 360 10 8.086 5.399 33.000 32.000 362 11 8.881 5.312 30.000 28.500 361 12 9.595 5.217 28.000 26.000 359 13 10.232 5.394 40.000 39.000 358 14 10.409 5.450 36.000 34.500 359 15 10.762 5.485 30.000 28.000 357 16 11.087 5.397 32.000 31.000 355 17 11.262 5.184 31.000 30.400 353 18 10.764 4.780 25.000 23.500 354 19 10.266 4.919 33.000 32.000 354 20 9.879 5.015 28.000 27.000 354 21 9.256 5.022 27.000 28.400 356 22 8.781 5.299 28.000 27.400 356 23 8.383 5.140 28.000 27.400 356 24 8.070 4.944 26.000 25.500 357 TOTAL 8.888 5.388 47.000 46.500 8556 CUMULATIVE PROBABILITY DISTRIBUTION MAY 1, 79, 80 - OCT 31, 79, 80 CATEGORY OP. LIMIT CATEGORY POINTS CATEGORY PERCENT CUMULATIVE POINTS
< LIMIT CUMULATIVE PERCENT
< LIMIT 0.500 7
0.1 7
0.082 1.000 169 2.0 176 2.057 2.000 511 6.0 687 8.029 3.000 638 7.5 1325 15.484 5.000 1303 15.2 2628 30.712 7.000 1205 14.1 3833 44.794 9.000 1132 13.2 4965 58.023 12.000 1565 18.3 6530 76.312 16.000 1258 14.7 7788 91.013 23.000 652 7.6 8440 98.633 30.000 99 1.2 8539 99.790 40.000 15 0.2 8554 99.965 50.000 2
0.0 8556 99.988 70.000 0
0.0 8556 99.988 NUMBER OF VALID DATA POINTS = 8556 NUMBER OF MISSING DATA POINTS = 276 REPRESENTING 98.9-PERCENT VALID DATA
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-93 of 2-123 Revision 0, 2020 Job Number: 01-4122-00 TABLE 22 YORK RESEARCH CORPORATION ONE RESEARCH DRIVE, STAMFORD, CONNECTICUT 06906 CLIENT: CON EDISON CO. OF NY SITE: INDIAN POINT (10M)
PARAMETER: WIND SPEED (WINTER SEASON)
UNITS: MPH DIURNAL ANALYSIS NOV 1, 79, 80 - APR 30, 79, 80 OBSERV PARAM AVG PARAM STD DEV MAX VALUE RANGE VALID PTS 1
4.508 2.958 21.000 20.500 362 2
4.462 2.940 14.000 13.500 362 3
4.524 3.163 18.000 17.500 362 4
4.453 3.043 16.000 15.500 361 5
4.298 2.886 15.000 14.400 361 6
4.292 2.961 15.000 14.500 362 7
4.461 3.102 18.000 17.500 363 8
4.556 3.141 15.000 14.400 363 9
4.906 3.212 17.000 16.400 363 10 5.153 3.182 16.000 15.400 363 11 5.310 3.050 16.000 15.500 361 12 5.556 2.995 16.000 15.400 362 13 5.731 3.163 18.000 17.400 362 14 5.702 3.240 16.500 15.900 362 15 5.589 3.109 17.000 16.400 361 16 5.336 3.243 20.000 19.400 360 17 5.030 3.084 20.000 19.500 360 18 4.671 2.858 15.000 14.400 360 19 4.611 2.906 16.000 15.500 361 20 4.502 2.883 15.000 14.400 361 21 4.500 2.972 16.000 15.400 362 22 4.457 2.970 16.000 15.400 361 23 4.381 2.855 16.000 15.400 361 24 4.398 2.874 18.000 17.500 362 TOTAL 4.808 3.088 21.000 20.500 8678 CUMULATIVE PROBABILITY DISTRIBUTION NOV 1, 79, 80 - APR 30, 79, 80 CATEGORY OP. LIMIT CATEGORY POINTS CATEGORY PERCENT CUMULATIVE POINTS
< LIMIT CUMULATIVE PERCENT
< LIMIT 0.500 18 0.2 18 0.207 1.000 788 9.1 806 9.287 2.000 1332 15.3 2138 24.634 3.000 1178 13.6 3316 38.207 5.000 2122 24.4 5438 62.657 7.000 1591 18.3 7029 80.989 9.000 841 9.7 7870 90.679 12.000 614 7.1 8484 97.753 16.000 181 2.1 8665 99.839 23.000 13 0.1 8678 99.988 30.000 0
0.0 8678 99.988 40.000 0
0.0 8678 99.988 50.000 0
0.0 8678 99.988 70.000 0
0.0 8678 99.988 NUMBER OF VALID DATA POINTS = 8678 NUMBER OF MISSING DATA POINTS = 34 REPRESENTING 99.6-PERCENT VALID DATA
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-94 of 2-123 Revision 0, 2020 Job Number: 01-4122-00 TABLE 23 YORK RESEARCH CORPORATION ONE RESEARCH DRIVE, STAMFORD, CONNECTICUT 06906 CLIENT: CON EDISON CO. OF NY SITE: INDIAN POINT (122M)
PARAMETER: WIND SPEED (WINTER SEASON)
UNITS: MPH DIURNAL ANALYSIS NOV 1, 79, 80 - APR 30, 79, 80 OBSERV PARAM AVG PARAM STD DEV MAX VALUE RANGE VALID PTS 1
10.919 6.869 49.000 48.500 359 2
10.669 5.562 38.000 37.400 359 3
10.636 6.799 40.000 39.400 358 4
10.297 6.804 37.500 36.900 358 5
10.075 6.354 34.000 33.400 358 6
9.832 6.485 32.000 31.500 358 7
9.902 6.811 44.000 43.500 356 8
10.283 7.067 38.000 37.400 356 9
10.525 6.978 36.000 35.400 358 10 10.596 7.032 37.000 36.400 360 11 11.086 6.961 36.000 35.000 362 12 11.828 7.011 34.000 33.500 362 13 12.309 7.218 48.000 47.000 362 14 12.530 7.250 45.000 44.400 362 15 12.727 7.184 43.000 42.000 362 16 12.635 6.992 40.000 38.500 362 17 12.302 6.778 42.000 41.000 361 18 11.921 6.035 32.000 31.400 361 19 11.645 6.061 32.000 31.400 360 20 11.398 6.093 37.000 36.400 360 21 11.106 6.216 40.000 39.400 360 22 10.658 6.206 39.000 38.400 358 23 10.488 6.182 36.000 35.000 358 24 10.551 6.178 41.000 40.500 359 TOTAL 11.124 6.726 49.000 48.500 4629 CUMULATIVE PROBABILITY DISTRIBUTION NOV 1, 79, 80 - APR 30, 79, 80 CATEGORY OP. LIMIT CATEGORY POINTS CATEGORY PERCENT CUMULATIVE POINTS
< LIMIT CUMULATIVE PERCENT
< LIMIT 0.500 6
0.1 6
0.070 1.000 105 1.2 111 1.286 2.000 418 4.8 529 6.130 3.000 458 5.3 987 11.437 5.000 910 10.5 1897 21.981 7.000 895 10.4 2792 32.352 9.000 1009 11.7 3801 44.044 12.000 1622 18.8 5423 62.839 16.000 1518 17.6 6941 80.429 23.000 1230 14.3 8171 94.681 30.000 372 4.3 8513 98.992 40.000 78 0.9 8621 99.896 50.000 8
0.1 8629 99.988 70.000 0
0.0 8629 99.988 NUMBER OF VALID DATA POINTS = 8629 NUMBER OF MISSING DATA POINTS = 83 REPRESENTING 99.0-PERCENT VALID DATA
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-95 of 2-123 Revision 0, 2020 TABLE 24 MAXIMUM DIURNAL WIND SPEEDS (MPH)
Season Level (M) 1973-1974 1979-1980 Summer 10 4.0 4.1 Summer 120 11.0 11.3 Winter 10 5.0 5.7 Winter 122 13.0 12.7 The median wind speeds extracted from Figure 20 at the 50 percent probability level are 1.1 M/S, 1.7 M/S and 1.4 M/S at the 10 meter level for the summer season, winter season, and annual basis, respectively. At the 122 meter level, these values are 3.4 M/S, 4.4 M/S and 3.9 M/S on the summer, winter and annual basis, respectively. These values bracket those presented by Kaplin and Laznow (1972) for the IP3 Tower.
Corrected for exposure elevation no significant change would be expected between the two sets of values.
The variation of winds during the 1979-1980 season are consistent with data obtained during the 1973-1974 operational period. There is no reason to expect any significant variations with respect to the meteorology as used in FSAR 2.
3.2.4.5 Wind Velocities and Atmospheric Stability 3.2.4.5.1 Joint Frequency Distribution of Wind Direction and Stability Stability categorizations as referenced in this study are in accordance with NRC Pasquill Tables as derived from local temperature change with elevation. Except as noted, actual temperature measured gradients have been converted to °C/100M directly from temperature difference values (°F) per difference between sensor height levels.
Tables 25, 26 and 27 show the summary frequency distributions for the 10 meter level of wind direction and stability categories for the 1979-1980 data collection period. The tables show the annual, summer season and winter season summaries respectively.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-96 of 2-123 Revision 0, 2020 TABLE 25 ANNUAL
SUMMARY
OF WIND DIRECTION PERCENT FREQUENCY DISTRIBUTION AS A FUNCTION OF STABILITY - 10M LEVEL (JANUARY 1, 1979 - DECEMBER 31, 1980)
Stability Class Wind Direction A
B C
D E
F G
N 1.28 0.36 0.48 3.39 2.67 0.50 0.09 NNE 1.76 0.40 0.46 3.15 3.33 0.80 0.17 NE 0.63 0.35 0.58 4.22 4.66 2.12 0.40 ENE 0.06 0.07 0.17 1.59 2.61 1.84 0.43 E
0.01 0.03 0.03 0.64 1.49 0.59 0.11 ESE 0.01 0.01 0.01 0.27 0.73 0.21 0.04 SE 0.03 0.01 0.02 0.23 0.67 0.26 0.02 SSE 0.09 0.03 0.04 0.45 1.04 0.31 0.05 S
2.04 0.25 0.29 1.74 3.39 0.76 0.11 SSW 2.58 0.51 0.38 2.14 5.04 0.72 0.05 SW 1.16 0.33 0.35 1.89 3.03 0.51 0.03 WSW 0.49 0.17 0.16 0.96 1.44 0.39 0.02 W
0.56 0.22 0.17 1.40 1.64 0.43 0.06 WNW 0.47 0.15 0.26 1.64 1.49 0.21 0.03 NW 0.70 0.31 0.32 2.36 1.85 0.10 0.01 NNW 0.80 0.40 0.49 3.26 1.60 0.17 0.04 CALM 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MISSING 0.12 0.05 0.03 0.21 0.51 0.15 0.02 TOTAL %
12.80 3.66 4.23 29.56 37.17 10.08 1.69 NO. OF HOURS 2244 641 742 5183 6519 1768 297
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-97 of 2-123 Revision 0, 2020 TABLE 26
SUMMARY
OF WIND DIRECTION PERCENT FREQUENCY DISTRIBUTION AS A FUNCTION OF STABILITY SUMMER SEASON - 10M LEVEL (MAY 1, 1979, 80 - OCTOBER 31, 1979, 80)
Stability Class Wind Direction A
B C
D E
F G
N 1.68 0.26 0.37 1.25 2.06 0.57 0.07 NNE 2.65 0.42 0.43 2.90 2.41 1.01 0.18 NE 0.58 0.31 0.46 3.46 4.44 3.17 0.35 ENE 0.11 0.10 0.24 1.38 2.66 2.62 0.39 E
0.02 0.07 0.01 0.57 1.57 0.61 0.05 ESE 0.01 0.01 0.00 0.31 1.01 0.36 0.06 SE 0.05 0.02 0.01 0.17 0.84 0.40 0.02 SSE 0.15 0.06 0.05 0.50 1.07 0.40 0.08 S
3.32 0.36 0.43 2.47 3.58 0.85 0.05 SSW 4.10 0.75 0.59 2.93 5.70 0.85 0.01 SW 1.84 0.49 0.48 2.23 3.03 0.51 0.05 WSW 0.87 0.20 0.18 0.94 1.05 0.34 0.00 W
0.88 0.28 0.19 1.38 1.42 0.34 0.07 WNW 0.80 0.09 0.25 0.94 1.03 0.15 0.05 NW 1.05 0.19 0.17 0.84 0.63 0.10 0.02 NNW 0.78 0.19 0.24 0.97 0.74 0.20 0.02 CALM 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MISSING 0.22 0.06 0.01 0.31 0.68 0.22 0.03 TOTAL %
19.11 3.86 4.11 23.54 33.92 12.69 1.48 NO. OF HOURS 1687 341 363 2078 2994 1120 131
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-98 of 2-123 Revision 0, 2020 TABLE 27
SUMMARY
OF WIND DIRECTION PERCENT FREQUENCY DISTRIBUTION AS A FUNCTION OF STABILITY WINTER SEASON - 10M LEVEL (NOVEMBER 1, 1979, 80 - APRIL 30, 1979, 80)
Stability Class Wind Direction A
B C
D E
F G
N 0.87 0.46 0.60 5.56 3.28 0.44 0.11 NNE 0.85 0.38 0.49 3.41 4.26 0.59 0.16 NE 0.86 0.40 0.69 4.99 4.88 1.06 0.45 ENE 0.01 0.05 0.10 1.79 2.56 1.06 0.48 E
0.00 0.00 0.06 0.72 1.40 0.56 0.18 ESE 0.00 0.01 0.01 0.23 0.45 0.06 0.02 SE 0.02 0.00 0.02 0.29 0.49 0.11 0.01 SSE 0.02 0.01 0.03 0.40 1.01 0.23 0.02 S
0.75 0.13 0.14 1.01 3.19 0.68 0.17 SSW 1.04 0.28 0.17 1.34 4.37 0.59 0.08 SW 0.48 0.16 0.22 1.55 3.03 0.51 0.02 WSW 0.10 0.13 0.14 0.99 1.84 0.45 0.03 W
0.24 0.15 0.14 1.42 1.86 0.52 0.06 WNW 0.13 0.22 0.28 2.34 1.95 0.28 0.02 NW 0.34 0.42 0.47 3.90 3.09 0.10 0.00 NNW 0.83 0.62 0.75 5.58 2.47 0.14 0.06 CALM 0.00 0.00 0.00 0.00 0.00 0.00 0.00 MISSING 0.02 0.03 0.05 0.11 0.33 0.09 0.01 TOTAL %
6.39 3.44 4.35 35.65 40.47 7.44 1.91 NO. OF HOURS 557 300 379 3105 3525 648 161
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-99 of 2-123 Revision 0, 2020 There are distinctive seasonal biases that coincide with variations in wind direction occurrence frequencies. It will be seen that these biases are consistent with variations in stability and wind speed on diurnal basis.
3.2.4.5.2 Frequency of Occurrence of Stability Categories Table 28 shows a summary of historical comparison of percent occurrence of stability categories between the various reporting periods for the IP3 Tower and of the 122M Tower (IP4) for 1973/74. (Based on concurrent wind speed and temperature gradients).
The former gradients were based on temperature differences from the 30M and 2M levels while the latter were based on differential measurements between the 60M and 10M levels.
On an annual basis there is generally good agreement between the results for the 122M Tower and the IP3 Tower composite year with temperature correction (FSAR 3, Supplement 13, 16).
The variation in percentages at the stability extreme A and G are most probably related to the lower gradient base level of measurement on the IP3 Tower - 2 meters. One would expect higher or lower temperatures closer to the ground with less accuracy in the thermal adjustment factor in these extreme ranges.
Table 29 shows a similar comparison for the 122 Meter Meteorological Tower for the 1973-1974 data collection period and the 1979-80 data collection period. These results are based on current wind speed data for the tower levels as noted. The 122M is shown based on two gradient differences: 122-10M and 122-60M. The percent occurrences of stability categories are sharply defined functions of season and, for the upper level, the vertical defined functions of season and, for the upper level, the vertical temperature gradient. This is apparent in both data sets.
There are seasonal differences in the two data sets particularly in the A and G stability category extremes at the 122M level, however, is noted that the percent occurrences in the 1973-1974 data set are based on only one or less than ten observations where these percentage differentials are most extreme. Where more data points are available in each stability category as for the lower gradient level (61-10M), there is generally good agreement.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-100 of 2-123 Revision 0, 2020 TABLE 28 HISTORICAL COMPARISONS OF PERCENT OCCURRENCE OF STABILITY Temperature Stability Class No. of Gradient (M)
A B
C D
E F
G Observ.
Summer (1974) 61-10 21.44 5.46 4.37 27.92 30.21 9.28 1.31 2747 1973 (IP3)*
25.52 2.62 3.64 17.38 26.81 13.39 10.63 2935 Winter (1973/74) 61-10 4.00 1.92 2.13 23.93 53.24 12.53 2.25 4797 1973 (IP3)*
21.49 3.52 3.74 23.29 23.76 14.24 9.96 4229 Annual (1973/74) 61-10 10.35 3.21 2.94 25.38 44.86 11.35 1.91 7544 1970/72 (IP3)1 6.42 2.55 2.23 31.19 38.75 11.25 3.16 8366 1970 (IP3)*
21.68 2.20 3.39 33.35 24.75 9.01 5.62 NA 1971 (IP3)*
19.17 2.75 2.97 22.79 30.87 11.69 9.75 NA 1970/72 (IP3)1*
15.52 1.74 2.82 28.38 25.42 12.68 9.03 8366 1973 (IP3)**
23.14 3.16 3.70 20.87 25.02 13.89 10.23 NA
- Concurrent basis 1 Composite year with temperature correction - concurrent basis (FSAR 3) 1* Composite year concurrent basis (FSAR 3)
- March-December only concurrent basis NA Not Available NOTE: Gradient for IP3 Tower: 30-2 M
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-101 of 2-123 Revision 0, 2020 TABLE 29 COMPARISON OF PERCENT OCCURRENCE OF STABILITY ON 122 METER TOWER Wind Freq Stability Class No. of Temperature Date LVL (M)
A B
C D
E F
G Observ Gradient(M)
Summer 1974 10 21.44 5.47 4.37 27.92 30.21 9.28 1.31 2747 61 - 10 1979/80 10 19.34 3.93 4.22 23.96 34.35 12.73 1.48 8557 60 - 10 1974 122 0.51 0.66 2.15 47.40 41.54 7.72 0.04*
2747 122 - 10 1979/80 122 4.54 5.50 5.81 42.84 34.95 6.23 0.14**
7838 122 - 10 1974 122 0.04*
0.04*
0.11**
20.13 74.01 5.42 0.25**
2747 122 - 61 1979/80 122 0.17**
0.42 1.49 68.09 26.72 2.82 0.29 7838 122 - 60 Winter 1973/74 10 4.00 1.92 2.13 23.93 53.24 12.53 2.25 4797 61 - 10 1979/80 10 6.44 3.47 4.37 35.79 40.55 7.46 1.92 8648 60 - 10 1973/74 122 3.17 1.70 1.63 41.46 48.86 3.09 0.08**
4797 122 - 10 1979/80 122 0.59 1.18 2.78 56.07 34.75 4.29 0.31 8594 122 - 10 1973/74 122 0.02*
0.31 1.19 41.94 49.59 6.82 0.13**
4797 122 - 61 1979/80 122 0.28 0.14 0.37 71.89 25.35 1.84 0.13 8594 122 - 60 Annual 1973/74 10 10.35 3.21 2.94 25.38 44.86 11.35 1.91 7544 61 - 10 1979/80 10 12.86 3.70 4.30 29.90 37.47 10.08 1.70 17205 60 - 10 1973/74 122 2.63 1.33 1.82 43.62 46.20 4.77 0.07 7544 122 - 10 1979/80 122 2.48 3.24 4.23 49.76 34.84 5.22 0.23 16432 122 -10 1973/74 122 0.03 0.08 0.80 34.00 58.48 6.31 0.17 7544 122 - 61 1979/80 122 0.23 0.27 0.91 70.08 26.00 2.31 0.21 16432 122 - 60 It may be inferred that, except as stated for the reasons noted, the percent frequency of stability classes with the existing tower system is representative and consistent with data referenced in FSAR 2.
- Single observations
- Less than ten observations
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-102 of 2-123 Revision 0, 2020 3.2.4.5.3 Average Wind Speed and Diurnal Variation as a Function of Stability Categories Tables 30, 31, and 32 show the average wind speed and number of observations as functions of time of day and stability category for the summer and winter seasons of the combined 1979 and 1980 data collection period.
The results are derived from valid wind speeds measured at 10M relative to the temperature difference 60 - 10M and 122M wind speeds based on the temperature difference between 122-10M and 122-60M. The latter gradient was generated by subtraction of gradient levels:
(122-60) = (122-10) - (60-10)
These tables indicate a distinctive diurnal pattern to the stability. During the summer season at the 10M level for all practical purposes G stability does not occur between 0700 to 1900 EST and F stability does not occur between 0900 and 1400. During the nocturnal hours between 1900 to 0600, for all practical purposes A, B, and C stability categories do not appear. Stability Category A appears from 0700 to 1800 EST and is the dominant gradient between 0900 and 1600 EST. Out of 2,855 observations during this time interval, the percent frequency of occurrences were 52.9 for A, 8.1 for B, 8.4 for C, 24.2 for D, 6.1 for E, 0.2 for F, and 0.04 for G.
In the winter season at 10M, the A, B, and C stability categories do not appear during the nocturnal hours from 1900 to 0600 (with random singular exceptions). D is the dominant day time stability category and E is the dominant nighttime category.
Somewhat similar patterns are found with the upper level gradients based on the 122-10M and 122-60M temperature gradients. Between these latter two gradients TABLE 30 Diurnal Variation of Stability Class and Wind Speed (concurrent data)
TABLE 31 Diurnal Variation of Stability Class and Wind Speed (concurrent data)
TABLE 32 Diurnal Variation of Stability Class and Wind Speed (concurrent data)
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-103 of 2-123 Revision 0, 2020 TABLE 33 COMPARISONS OF AVERAGE WIND SPEEDS (MPH)
AS A FUNCTION OF STABILITY Year/
Anemom Stability Class Temperature Season LVL A
B C
D E
F G
Gradient (M)
Summer 1974 10M 4.2 4.4 4.0 3.8 2.7 2.3 2.6 60 - 10 1979/80 10M 4.0 3.6 3.5 3.7 2.7 2.1 2.2 60 - 10 1974 122M 4.3**
14.3 12.3 9.5 7.7 4.5 4.5*
122 - 10 1979/80 122M 11.2 10.4 9.8 10.0 7.6 4.8 4.3**
122 - 10 1974 122M 3.5*
49.0*
3.8**
10.6 8.2 4.4 2.6**
122 - 60 1979/80 122M 9.3**
12.6 12.1 10.0 6.4 4.3 4.0 122 - 60 Winter 1973/74 10M 4.8 5.2 4.8 6.1 5.0 2.4 2.3 60 - 10 1979/80 10M 5.9 6.4 6.0 5.9 4.0 2.2 2.8 60 - 10 1973/74 122M 15.8 11.5 10.1 13.5 9.0 5.7 3.6**
122 - 10 1979/80 122M 13.9 12.4 13.9 12.9 8.6 5.6 8.6 122 - 10 1973/74 122M 16.0*
15.0 13.9 13.3 9.7 6.0 4.7**
122 - 60 1979/80 122M 19.9 21.0 20.4 12.3 7.8 7.2 6.3**
122 - 60 for the same data base the number of occurrences of A, B, and C stability categories in both summer and winter seasons are substantially reduced and become almost random when based on the 122-60M gradient. The obvious implication is that temperature gradient extremes are controlled by the surface level. This is consistent with Kaplin, et.
al., 1974.
At the upper levels, for the summer season, F stability has a distinct diurnal function. It rarely occurs during the daytime from 0800 to 2000 EST. The distribution of G stability during the summer season, while a diurnal function, is clearly biased to the early morning hours. It occurs more frequently with relation to the 122-60M gradient than the 122-10M gradient. These factors are consistent with a nocturnal cool air surface drainage flow. This routine drainage flow does not exist during the winter season, and the occurrence frequencies, while still diurnal, are clearly related to the local surface air temperatures.
It is noted that during the winter seasons, drainage flow patterns are not routine occurrences. They can occur, however, during periods of weak pressure gradients.
They are dependent on the horizontal and vertical temperature gradients that develop between the land (snow covered or bare ground) as well as the Hudson River (free water or ice bound).
The average wind speeds as a function of stability category are shown in Table 33 for the 1973-1974 data collection period and the 1979-1980 data period. As noted, there are some apparent anomalies with respect to the 122 meter level wind speeds. These
- Single observations
- Less than 15 observations
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-104 of 2-123 Revision 0, 2020 are probably induced by the few data points available in 1973-1974 rather than a reality. Where the total number of occurrences were in a more reliable range, at the 10 meter and the 122 meter levels, there was good agreement between average wind speeds.
Based on these data, it is concluded that within the range of normal climatological variations, there are no significant changes in the local meteorological parameters on a seasonal and annual basis. The existing meteorological data are consistent with data referenced in FSAR 2.
4.0
SUMMARY
4.1 METEROROLOGY 4.1.1 General The meteorology of the Indian Point site and its environs has been thoroughly studied over the span of years. For the past nine years the source of on-site meteorology has been the 122 Meter Meteorological Tower that became fully operative as of October 1, 1973. This tower is located at latitude: 41° 15 55 N and longitude 73° 57 08 W (N38 + 31.453 and E22 + 49.473 on the Indian Point Grid).
A review of data and literature has revealed that the original Coordinates above were based on pre-1983 topographical maps that used North American Datum 1927 (NAD27) for its basis. The geodetic gurus revised the standards in the 1980s, and in the United States the USGS adopted the North American Datum 1983 (NAD83) model of the Earths curvature, and the international community adopted WGS84 (World Geodetic System 1984) the following year, which is essentially the same model. WGS84 is the default map datum built into all GPS receivers, and is also the basis for most electronic maps including Google, MapQuest, Microsoft, Bing, etc. Also, depending upon the GPS unit or mapping system used, the numbers vary. The latitude and longitude coordinates for the met tower were only used to provide location information to the FAA when tower lights were out and the FAA no longer requests latitude and longitude information. Based on this information, the above coordinates should not be used to locate the primary tower.
Meteorological data from the 122 Meter Tower have, in previous studies and in this report, have been compared, in so far as possible, to those meteorological data, which were the data base for the FSAR 2 Report.
4.1.2 122 Meter Meteorological Tower System The 122 Meter Tower and support systems as presently comprised, maintained, and operated are in compliance with the meteorological measurement programs included in Regulatory Guides 1.23 and 1.97 and the criteria set forth in NUREG-0654, -0696, and
-0737.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-105 of 2-123 Revision 0, 2020 The system is outlined in Figure 4. It consists of an instrumented 122 Meter Tower.
The critical sensors are for winds at the 10, 60, and 122 meter levels; ambient temperature and dew point at the 10 meter level and temperature difference between the 60-10 meter and 122-10 meter levels. In addition, a precipitation gage is located within the tower complex. All sensor signals are carried to a trailer, which houses:
Signal Conditioners Analog Recorders Data Acquisition System - Magnetic Tape Terminal Printer LED Satellite Displays for Control Rooms 2 and 3 Telephone Modems Dedicated Telephone Lines Air Conditioning Systems All systems are operated on primary AC voltage. A backup diesel generator within the complex provides for the automatic transfer of power if the primary source is cut off.
Appropriate meteorological data are transmitted from the Meteorological Trailer to:
Reactor Control Rooms 2 (CON-EDISON) and 3 (PASNY)
MIDAS and ARAC Computers The Emergency Control Center in addition to the computer systems and interrogation systems receives wind data from backup wind sensors.
The status of the backup wind system and the MIDAS computer may be assessed by remote telephone interrogation.
4.1.3 Local Meteorological Characteristics All earlier studies and the data evaluated and included in this report indicates that the most important characteristic of the Indian Point area is the prevalence of winds from the north and south sectors. These winds are induced by meso-scale factors: terrain channeling at all times and drainage flow and land-sea circulations during periods of weak synoptic-cyclonic scale pressure gradient field.
At all wind levels there are distinctive diurnal variation patterns to local winds as well as to the local winds in addition to the local atmospheric stability as determined by vertical temperature gradients related to Pasquill stability categories. Unstable A, B, and C categories are dominant daytime occurrences. Stable F and G categories are nocturnal occurrences.
Because of the dominance of meso-scale factors in the Indian Point and lower Hudson Avenue Valley environs, persistent straight line flow of air from Indian Point is impossible. Paths of movement of air parcels are best generated by the use of local data on a real time basis. Recirculation of air parcels within a time frame of eight consecutive hours is a likely event. Within ten miles of Indian Point there are three zones, which indicated the probability of convergence and divergence of local surface air streams:
Peekskill Bay Haverstraw Bay Tappan Zee
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-106 of 2-123 Revision 0, 2020 4.1.4 Conclusion From the evaluation of previous studies and the recent data years January 1, 1979 -
December 31, 1980, it has been concluded that the meteorological data being collected at the 122 Meter Meteorological Tower are representative of the Indian Point site and are consistent with the original and expanded meteorological data basis of FSAR for Unit No. 2. All deviations of data at any given time (not otherwise specifically assigned to measurement techniques, methodologies, and, evaluation procedural changes to comply with existing Regulatory Guides) can be assigned to normal regional climatological variations in any given year on, at least, the synoptic-cyclonic meteorological scale.
5.0 REFERENCES
- 1)
Halitsky, James, J. Laznow and D. Leahey, (1970): Wind Observations at Indian Point, Montrose and Bowline Point, 31 August 1968 to 30 June 1969. New York University, School of Engineering and Science, Department of Meteorology and Oceanography, G.S.L. Technical Report No. TR-70-3, February, 1970.
- 2)
Halitsky, James, E. J. Kaplin and J. Laznow (1971): Wind Observations at Indian Point, 26 November 1969 to October 1970. New York University, School of Engineering and Science, Department of Meteorology and Oceanography, G.S.L.
Technical Report No. TR 71-3, May, 1971.
- 3)
Kaplin, Edward J. and J. Laznow (1972): Meteorological Observations at Indian Point, Trap Rock, Montrose Point and Cape Charles, 1 January 1970 to 31 December 1971. New York University, School of Engineering and Science, Department of Meteorology and Oceanography, G.S.L. Technical Report No. TR-73-1, December, 1972.
- 4)
Kaplin, Edward J., J. Laznow and M. M. Wurmbrand (1972): Selection of Air Monitoring Locations, Calculations of Dispersion Patterns for Diffusion Overlays, and Recommendations for a Meteorological Program to Satisfy A.E.C. Safety Guide.23 at the Indian Point Complex. New York University, School of Engineering and Science, Department of Meteorology and Oceanography, G.S.L.
Technical Report No. TR-72-3, July, 1972.
- 5)
Kaplin, Edward J. and C. E. Kitson (1974): Final Report - Meteorological Services and Data Evaluation Indian Point 100 Foot Tower. York Research Corporation Report NO. Y-8127, September, 1974.
- 6)
United States Atomic Energy Commission Safety Guide 23 - Onsite Meteorological Programs, February 17, 1972.
- 7)
Kaplin, Edward J., M. Kozenko and J. Kirschner (1974): Report No. 1, Meteorological, Ambient Salt Studies and Upper Air Studies at Indian Point, Buchanan, NY, York Research Corporation Report No. Y-8162/8166, January, 1974.
- 8)
Kaplin, Edward J., C. E. Kitson, and M. Kozenko (1974): Final Report:
Meteorological, Upper Air and Ambient Salt Studies, York Research Corporation Report Nos. Y-8162 and Y-8166-2, October, 1974. (With Appendices A-N, I and II)
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-107 of 2-123 Revision 0, 2020
- 9)
U.S. Nuclear Regulatory Commission (1980): NUREG-0654 (FEMA-FEP-1),
Criteria for Preparation and Evaluation of Radiological Emergency Response Plans and Preparedness in Support of Nuclear Power Plants: Appendix 2, Meteorological Criteria for Emergency Preparedness at Operating Nuclear Power Plants, January, 1980.
- 10)
U.S. Nuclear Regulatory Commission (1980): Proposal Revision 1 to Regulatory Guide 1.23 - Meteorological Programs in Support of Nuclear Power Plants, September, 1980.
- 11)
Kaplin, Edward J. and B. Wuebber (1979): Final Report, Surface Air Trajectory Analyses, York Services Corporation Report No. 1-1025, December, 1979.
- 12)
Kaplin, Edward J. (1979): Executive Summary, Final Report, Surface Air Trajectory Analysis, York Services Corporation Report No. 1-1025-1, December, 1979.
- 13)
Kaplin, Edward J. and B. Wuebber (1981): Final Report Indian Point Trajectory II Study, York Services Corporation Report No. 01-4013, July, 1981.
- 14)
FSAR: Final Facility Description and Safety Analysis Report, Consolidated Edison Company of New York, Inc., Nuclear Generating Station No. 2.
- 15)
FSAR: Final Facility Description and Safety Analysis Report, Consolidated Edison Company of New York, Inc., Nuclear Generating Station No. 3.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-108 of 2-123 Revision 0, 2020 NOTE: This information is classified as Historical Information APPENDIX 2B INDIAN POINT FSAR UPDATE REVISED Prepared for:
Consolidated Edison Company, Inc.
of New York 4 Irving Place New York, NY 10003 Submitted by:
WOODWARD-CYCLE CONSULTANTS 201 Willowbrook Boulevard Wayne, New Jersey 07470 16 April 1982
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-109 of 2-123 Revision 0, 2020 TABLE OF CONTENTS Page No.
INTRODUCTION Physiography 2.7A-1 General Geology and Tectonics 2.7A-2 Geology of the Hudson Highlands 2.7A-3 Geology of the Manhattan Prong 2.7A-4 The Geology of the Newark Basin 2.7A-7 History of Brittle Deformation 2.7A-8 Recent Seismicity 2.7A-12 CONCLUSION 2.7A-15 REFERENCES R-1 GLOSSARY G-1 TABLES Table 1 - Geologic Time Scale Table 2 - Stratigraphic Correlation Chart Table 3 - Geologic History in the Croton Falls Area FIGURES Figure 1 - Location Map Figure 2 - Seismotectonic Map
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-110 of 2-123 Revision 0, 2020 INDIAN POINT FSAR UPDATE INTRODUCTION This report is intended as an update and synthesis of previous geologic reports on the area surrounding Con-Edisons Indian Point nuclear facilities. The report reflects current thinking on the geology, structure, tectonic history, neotectonics and recent seismicity in the region. Main sources of information include Ratcliffes (1976) final report on the Ramapo fault system, the Dames and Moore Geotechnical Investigation of the Ramapo Fault (1977), and the recent literature on the subject of the geology of the Manhattan and Reading Prongs.
Con Edisons Indian Point power plants are located in Buchanan, New York, on the east bank of the Hudson River. The site is situated in the central portion of the Peekskill Quadrangle.
Physiography The rocks in the vicinity of the Indian Point generating stations belong to three geologic provinces, the Hudson Highlands, the Manhattan Prong and the Newark Basin (Figure 1).
Rocks that outcrop within the provinces range in age from Precambrian through Triassic (Jurassic?).
The landscape consists of northeast trending ridges and rather broad swampy valleys.
Ridges are supported by bedrock and tend to follow prominent generally northeast, structural trends. Valley walls tend to be steep, the result of modification by Pleistocene glaciation. Elevations in the area reach a maximum of 1000 feet, and range from 50 to 300 feet above sea level in low lying areas.
General Geology and Tectonics The eastern third of the North American continent has been the site of episodic tectonism since Precambrian time (see Table1). Paleozoic aged tectonism has molded a broad geologically varying zone known as the Appalachian orogen. The core of the orogen is marked by intrusive rocks modified by ductile and brittle deformation and regional metamorphism. The Indian Point site lies within the Manhattan Prong of the Appalachian Mountains.
The earliest recognized event in the area occurred in Precambrian time, and is known as the Grenville Orogeny. The Grenville orogeny, dated at 1.1 b.y., produced brittle and ductile deformation accompanied by regional granulite facies metamorphism and intrusive activity. The deformation and metamorphism affected the rocks of the Reading Prong and the Precambrian rocks of the Manhattan Prong. The Grenville events are not tectonically or temporarily related to the development of the Appalachian Orogen, which began in the latest Precambrian.
The earliest tectonic activity in the Appalachian Orogen probably involved latest Precambrian continental rifting and associated intrusive activity. The opening of the Proto-Atlantic Ocean (Iapetus) set the stage for the development of the Appalachian geosyncline. The geosyncline received sediments from earliest Precambrian through the mid-Ordovician time. The Taconic orogeny occurred in Mid-Ordovician time, and
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-111 of 2-123 Revision 0, 2020 resulted in extensive thrust faulting, folding, metamorphism and intrusion in the northern Appalachians. The Taconic orogeny, generally interpreted as a continent-island arc collision was very intense in the Manhattan Prong region, and produced most of the structure evident in the current map pattern.
The Acadian orogeny (Devovian), possibly a continent-continent collision, was the next pulse of orogenic activity. The Acadian orogeny caused considerable deformation, metamorphism and intrusion in New England, but was not as intense as the Taconic orogeny in the Manhattan Prong.
The rocks of the Hudson Highlands (see Figure 1), an extension of the Reading Prong in New York State, consist of Precambrian gneisses and granites of Grenville (1.1 b.y.) age.
The Manhattan Prong is underlain by Precambrian basement. An unconformity separates Cambro-Ordovician aged metasedimentary rocks from Precambrian rocks.
The Newark Basin is filled with Triassic (Jurassic?) arkosic sediments diabase intrusives and basaltic flows.
Geology of the Hudson Highlands The Hudson Highlands outcrop in a northeast (040°) trending belt, approximately 10-miles wide, north, northwest and west of the Indian Point site (Figure 1). Four major rock types are present in the vicinity of Dunderburg Mountain, across the Hudson River from Indian Point. They are quartzo-feldspathic +/- calc-silicate hornblende gneiss; migmatitic quartzo-feldspathic biotite +/- gamet gneiss; calc-silicate bearing quartzite; and gneissic hornblende granite. Granite probably intruded the gneisses during Precambrian time.
Heleneck and Mose (1978) mapping in Highlands rocks near Lake Carmel, New York, recognize a mappable sequence of five rock units consisting of, gray migmatitic quartzo-feldspathic gneiss; amphibolite hornblende gneiss; leuco-granite gneiss and amphibolite; layered quartzo-feldspathic gneiss; and interlayered feldspathic quartzite and amphiboite. Highland rocks represent a sequence of Precambrian aged mio-and eugeosynclinal deposits, that have undergone a complex sequence of metamorphism and deformation. The rocks typically yield Rb/Sr ages of 1.1 billion years, the time of Grenville regional metamorphism. Mineralogic and textural evidence indicates that the rocks were metamorphosed to granulite facies, and multiply deformed during the Grenville orogeny. Recrystallization from granulite toemphibolite facies in Highland rocks near Lake Carmel accompanied folding during the Taconic orogeny (mid-Ordovician). Evidence of Taconic recrystallization in other areas of the Highlands remains equivocal. The Highlands are separated from the rocks of the Manhattan Prong and the Newark Basin by a complex fault system known as the Ramapo Fault Zone.
Geology of the Manhattan Prong The Manhattan Prong is a sequence of highly deformed metamorphic rocks, trending north-northeast, from New York City through Westchester County and western Fairfield County, Connecticut. The prong is bounded on the east by Camerons Line, a complicated structure possibly representing a suture between two crustal blocks. On the west, the prong is bounded by the Newark Basin border fault and the Hudson River.
The stratigraphy of the Manhattan Prong has long been the subject of controversy and frequent revision, however, most recent workers recognize five formations within the prong. In order of decreasing age they are the Fordham Gneiss, the Yonkers-Pound
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-112 of 2-123 Revision 0, 2020 Ridge Granite, the Lowerre Quartzite, the Inwood Marble and the Manhattan Schist (see Table 2). The Fordham and Yonkers formations are Precambrian in age, and are separated from the Cambro-Ordovician aged Lowerre, Inwood and Manhattan formations by an angular unconformity. The relative ages of the Fordham and Yonkers formations are not known with absolute certainty. The Fordham is generally considered at least Grenville in age, and the Yonkers latest Precambrian.
Halls (1968) detailed subdivision of the rocks of the Manhattan Prong near White Plains, New York, served as a basis for more recent workers. Correlations of the White Plains stratigraphy to other parts of the prong are tenuous due to the complex structural and metamorphic history of the area. Difficulties in correlation are compounded by the possibility of changes in original sedimentary facies.
The Fordham was divided into five members by Hall. They are:
Fordham A - Brown weathering garnet biotite quartzo-feldspathic gneiss.
Fordham B - Gray garnet biotite quartz feldspar gneiss interlayered with amphibolite.
Fordham C - Gray biotite hornblende quartzo-feldspathic gneiss with some amphibolite.
Fordham D - Rusty weathering sillimanite-garnet biotite quartzo-feldspathic gneiss.
Fordham E - Silliceous biotite-quartz plagioclase gneiss.
Most of the Fordham rocks probably represent metamorphosed eugeosynclinal deposits, interbedded with mafic volcanics. The Fordham formation was deformed and metamorphosed to granulite facies during the Grenville orogeny. Mineralogic and structural evidence indicates that the Fordham was recrystallized and deformed during Plaeozoic orogenesis.
The Yonkers Granite is thought to represent a metamorphosed rhyolite, emplaced during the opening of the Proto-Atlantic in late Precambrian time.
The assignment of formation status to the Lowerre, has been the subject of debate for nearly 100 years. It was first named and described by Merril in 1896, but many workers in the 20th century preferred to consider the Lowerre as part of the Fordham. In addition, the unconformity between the Cambro-Ordovician rocks and the Fordham, has not been recognized by all workers in the prong. The Lowerre is a relatively thin (40-ft.
thickness), discontinuous unit representing an arkosic sandstone. The discontinuity of the unit is probably the result of deposition on an irregular Precambrian aged erosional surface. The Lowerre consists of quartz, with considerable amounts of potassium feldspar and minor biotite. The Lowerre is always observed in the same stratigraphic position, at the base of the Cambro-Ordovician aged cover rocks, overlying and truncating various members of the Fordham.
The Inwood Marble, consisting of dolomite and calcite marble interlayered with calc-silicate schists, overlies the Lowerre. Hall has divided the Inwood into five members, that lens in and out. In map pattern, the Inwood does not appear to be continuous, the result of tectonic thinning of fairly ductile marble during deformation. The Inwood
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-113 of 2-123 Revision 0, 2020 represents deposition on a carbonate bank, widespread in the Appalachian orogen during the late Cambrian and early Ordovician.
In the White Plains area, Hall recognizes three mappable members of the Manhattan, A, B, and C (see Table 2). Manhattan A (basal Manhattan) is a fissile sillimanite garnet biotite schist, interlayered with marble and calc-silicate schist. The Manhattan A may be a transitional facies between carbonate and clastic sedimentation. It is recognized by Ratcliffe (1976) near the Cortlandt complex, and by Brock (1977) north of White Plains.
Manhattan B is a discontinuous amphibolite and Manhattan C is a brown weathering, garnet muscovite biotite schitose gneiss. The Manhattan Formation was originally deposited in a miogeosyncline, and represents pelites, mafic volcanics and greywackes.
The Manhattan Prong was metamorphosed, deformed and intruded during two major orogenic episodes, the Taconic (late Ordovician) and the Acadian (Devonian). A late Acadian metamorphic and deformational event can be recognized in some locations within the prong (Brock and Mose 1979). Mose and Hall (1979) infer a mid-Ordovician unconformity within the New York City group based on structural and isotopic evidence.
Brock (1977) has worked out a detailed sequence of events for the Manhattan Prong near Croton Falls, New York (see Table 3). The rocks of the prong were metamorphosed to K-feldspar sillimanite grade (upper amphibolite facies) at the peak of the Taconic orogeny. At this time the rocks underwent intense deformation, reflecting the effects of four distinct fold events during the orogeny. Taconic aged recrystallization affected the Precambrian rocks of the Manhattan Prong, destroying most Grenville aged metamorphic and structural features. Granulite facies mineralogy and textures survive as relicts within the Fordham, but are not present in the Cambro-Ordovician rocks, supporting the inferred unconformity between Fordham and younger rocks.
During Silurian time, deformation eased, but the prong was intruded by the Croton Falls and Cortlandt mafic complexes. The Acadian orogeny (Devonian) produced another set of folds (F5), metamorphism of kyanite-staurolite (mid-amphibolite facies) grade, and the intrusion of the Peekskill Granite. The final Paleozoic metamorphic and deformational event occurred late in the Acadian Orogeny or during the Mississippian, causing local retrograde metamorphism (muscovite grade) and folding (F6) (Brock, 1977). The final orogenic event is seen locally as tight isoclinal folds. Late metamorphism is evidenced by recrystallization on undeformed joint faces.
The ductile deformation occurred coevally with brittle deformation along the border fault and within the Manhattan Prong. The relationship of Precambrian, Paleozoic and post Paleozoic aged faulting will be discussed in a following section.
One of the significant problems involving rocks of the Manhattan Prong is correlation on a regional scale (see Table 2). The Fordham Formation is often correlated with the Precambrian Highlands gneisses. Some workers have tried tracing the Highlands across the boundary fault, comparing structure and metamorphic details with Fordham rocks.
Correlation is tenuous since the Grenville age yielded by the Highlands and Fordham rocks, is a metamorphic age, not a time of deposition. Correlation of the rest of the New York City Group with rocks of the surrounding region is based on similarities in lithology, structural position, radiometric age determinations and fossil evidence. The Lowerre is considered the metamorphosed equivalent of the Poughquag Sandstone. The Inwood is correlated with the Wappinger Limestone Group, and the Manhattan with the Annsville Phyllite and Hudson River Shale. Metamorphism increases from chlorite grade near the Hudson River, to K-feldspar-sillimanite grade near the Connecticut border.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-114 of 2-123 Revision 0, 2020 The Geology of the Newark Basin The third geologic province in the area is the Newark-Gettysburg Basin. The basin extends 140-miles from York County, Pennsylvania, to Rockland County, New York (Figure 1). The basin, a down dropped crustal block, formed during Mesozoic time.
Deposition was continuous from the late triassic through the upper Jurassic (Dames and Moore, 1977). Intrusion of the Palisades sill apparently occurred during deposition of sediments in latest Triassic-earliest Jurassic. The extrusion of the Watchung basalt flows followed later in the Jurassic. Rocks of the Newark series are in contact with the crystalline rocks of both the Manhattan and Reading Prongs, but the nature of the contact varies. At the northeastern edge of the basin, Triassic sediments unconformably lie over the Highland rocks, while the northeastern edge of the basin is in fault with the rocks of the Highlands.
The Newark Group is divided into four formations, the Hammer Creek Conglomerate, the Stockton Arkose, the Lockatong Argillite, and the Brunswick Shale and Sandstone.
Deposits of conglomerate and sedimentary breccia lie at the edges of the basin, reflecting proximity to the uplifted Precambrian and Paleozoic rocks that are the sources of the Triassic aged sediments.
The boundary fault between the Newark series and older crystalline rocks is the Ramapo fault. Movement along the fault and subsidence of the basin, concurrent with sedimentation, produced the half-graben configuration of the basin. The rocks within the basin are not greatly deformed, displaying broad open folds of uncertain origin, gentle dips of strata, and minor faults with small offsets.
History of Brittle Deformation A series of north-northeast trending faults pass through the area surrounding the Indian Point sites. The faults, some of which have been episodically active since the Precambrian time are collectively known as the Ramapo fault system. The system is composed of a number of parallel to sub-parallel branches and draws its name from the Ramapo fault, the boundary between the Reading Prong and the Newark Basin.
Ratcliffe (1976) mapped the faults in the vicinity of the Indian Point site, and interpreted a chronologic sequence of fault movements. Ratcliffe classified faults utilizing radiometric ages, cross-cutting lithologic relationships, and textural evidence. Dames and Moore (1977) utilize Ratcliffes conclusions, and present evidence for timing fault movements based on geothermometry of fluid inclusions in calcite. More recently, Nelson (1980) and others have examined the stratigraphy and pollen remains in swamps and sag ponds along the Ramapo, seeking evidence of Post-Pleistocene faulting in the area. In addition, Aggarwal and Sykes (1978), Yang and Aggarwal (1981) Dames and Moore (1977), and Woodward-Cylde Consultants (Quarterly Reports, Jan 1977 - Jan 1982) have studied the recent seismicity in the region, solving for magnitude and location of earthquake epicenters.
The earliest documented movement along the Ramapo fault system is Grenville age (Ratcliffe 1976). Textural evidence seen in the Canopus Pluton indicates that movement along the Canopus Hollow fault (north of Peekskill) was synchronous with emplacement of the pluton. Flow structures and mylonitization displayed within the pluton indicate crystallization during shearing. Drag folds and the overall shape of the pluton suggest right lateral strike-slip motion. The Canopus Pluton, a diorite-monzontie,
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-115 of 2-123 Revision 0, 2020 has been radiometrically dated at 1150 m.y. (Rb/Sr), thus providing a minimum age for movement along the fault.
The Lake Peekskill fault is defined by a shear zone in the Precambrian gneisses that has not affected the Annsville Phyllite (Ordovician). The fact that the Annsville has not been deformed, places a limit on the last motion along the fault. Ratcliffe (1976) states that both the Canopus Hollow and Lake Peekskill faults were not reactivated during Paleozoic time, however, in a more recent article (Ratcliffe 1980) he suggests that movement as recent as Triassic has taken place within the Canopus Fault Zone.
Dames and Moore (1977) disagree with Ratcliffes 1976 opinion, citing as evidence a sheared inlier of Poughquag Quartzite near Canopus Lake. The shear zone is considered by Dames and Moore to reflect thrust faulting along a northeast trending fault, sub-parallel to the Canopus Hollow fault. This implies post-Precambrian reactivation along the Canopus Hollow Fault. An additional strike-slip shear zone was mapped by Dames and Moore in Highland rocks, near the southwest corner of Canopus Lake, along the strike of the Canopus Hollow fault. This shear is considered additional evidence for reactivation of the Canopus Hollow fault in Paleozoic time. It is important to note that local activity occurring along part of a fault does not require movement along the entire length of a fault. Furthermore, the shear zone that displaces the Poughquag is not necessarily an extension of the Canopus shear zone, and may in fact be related to Paleozoic aged folding. Thus, Paleozoic aged movement along the Canopus Hollow fault is not required in the vicinity of Indian Point.
A number of faults of Paleozoic age separate the Manhattan Prong from the Hudson Highlands. Most prominent are the Thiells fault, the Annsville fault, the Peekskill fault and the Croton Falls fault. The Peekskill and Croton Falls faults outcrop on the east bank of the Hudson River, and generally trend east-west. The Thiells fault, outcropping on the west bank of the Hudson, and the Annsville fault on the east bank trend northeast.
The Ramapo fault extends northeast from Peapack, New Jersey separating the Newark Basin from the Reading Prong. At Ladentown, it splays into two branches, trending 020° and 060°, respectively. The 060° branch connects with the Thiells fault, and the more northerly trending branch extends into the Highlands, through Tomkins Cove, New York.
The Peekskill, Croton Falls, Thiells and Annsville faults are primarily Paleozoic in age.
The faults are marked by mylonite and ultra-mylonite, displaying retrograde chlorite grade, green schist facies mineral assemblages. Movement along the faults is generally right-lateral-strike-slip. Mid-Ordovician minimum ages of movement are inferred from cross-cutting relationships with dikes related to the Rosetown Pluton (mid-Ordovician),
and radiometric ages of undeformed biotites from within shear zones (Ratcliffe, 1976).
A lower Devonian K-Ar age of 396 m.y. places the most recent probable movement along the Roa Hook branch of the fault squarely within the Acadian orogeny. Similar data is available for the Thiells fault.
Younger faults can be distinguished from Paleozoic aged and older faults (Ratcliffe, 1980) by their different mineralization, and cataclastic textures. Younger faults are characterized by open work breccias, clay gouge, platy fracture and deeply incised fault scarps. Older faults display healed breccia, semi-ductile mylonite shear zones, and higher temperature minerals that reflect the general pattern of Paleozic aged regional metamorphism.
Reactivation and development of new faults occurred during Mesozoic time (Ratcliffe, 1980). Deep seated zones of weakness in crystalline basement were utilized in the
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-116 of 2-123 Revision 0, 2020 development of the Triassic basin, particularly the Ramapo-Cheesecote and Mott Farm Road faults (Ratcliffe, 1976). Structural evidence indicates that normal faulting was dominant during mesozoic time, with the latest activity along the Mott Farm Road branch of the Ramapo, dated at 163 m.y. by K-Ar methods (Ratcliffe, 1976). Late north-south vertical strike-slip faults with both left-lateral and right-lateral movements are present in the vicinity of Indian Point. The relationship of these faults to the Ramapo is uncertain, although the faults are probably Mesozoic in age (Ratcliffe, 1976; Dames & Moore, 1977).
Detailed work (Ratcliffe, 1976) shows that north-south faults at Tomkins Cove across the river from Indian Point are the youngest in the area. Mineralogy and textures found in the young, Tomkins Cove faults bear a strong resemblance to faults that have been radiometrically dated as Mesozoic. In addition, the time of last movement along the faults is constrained by the lack of fault related deformation in overlying Pleistocene sediments (Ratcliffe, 1976, 1980; Dames and Moore, 1977). A group of faults located at the Indian Point site was mapped in detail by Dames and Moore (1977). Displacement along the faults is not significant, no more than a few feet. The faults are filled with undeformed euhedral calcite crystals, many of which contain fluid inclusions.
Temperature equilibrium studies on the fluid inclusions indicate average formation temperatures of 160°C. Dames and Moore (1978), infer a depth of formation, by applying the geologically conservative geothermal gradient of 50°C/km. This yields a temperature of 150°C at 3 km.
The amount of time necessary to expose rocks that form at a depth of 3 km is a function of denudation rates. A minimum of 45 m.y. is required to remove 3 km of material, if the rather rapid denudation rate of 15,000 yrs/meter is applied (Dames and Moore, 1978). This calculation sets another constraint on the possible minimum age of last movement on the faults. The growth of calcite in the fault zones has been attributed to circulating hydrothermal fluids related to Mesozoic igneous activity (Dames and Moore, 1978), suggesting a time of last movement in the Mesozoic.
Radiometric age determination of undeformed minerals that have grown within fault zones (Ratcliffe, 1976) and the lack of fault related deformation of Pleistocene deposits and surface features (Dames and Moore, 1977); Ratcliffe 1976, 1980), provide the best evidence that the faults in the Indian Point area have not moved in the last two million years. Data from recent drill cores that intercepted the Ramapo fault plane, show that the dip of the structure is highly variable. The cores, taken at four locations along the fault, indicate that the dip is consistently to the southeast, ranging from 45° through 70° (Ratcliffe, 1980). Textural evidence observed in the cores, indicate that the dominant latest motion in the fault has been right oblique normal faulting (Ratcliffe, 1980).
Recent Seismicity In the last twenty years, the catalogue of instrumentally recorded seismic events in the northeast has grown tremendously. Locally, this is the result of a dense network of seismic stations, situated in the area around Indian Point, that has been operated since 1975. Data collection by regional seismic stations has continued in the same area since 1970 with a reported detection threshold of about magnitude 2 mb (Lg). Seismic networks have provided a basis for accurately determining the location, magnitude, and in some case focal mechanism solution for many small magnitude seismic events in the area of the power plant and the Ramapo fault zone. This recent seismicity is not markedly dissimilar from the historical seismicity reported for the region. The composite data set does not define or suggest a structural association of earthquakes, however, a
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-117 of 2-123 Revision 0, 2020 regional overview does suggest a higher level of activity in the northern New Jersey, southeastern New York area than that of the surrounding areas.
A number of hypotheses have been proposed to explain the observed pattern of seismicity. Current seismicity in the northeastern United States has been attributed to:
a proposed stress system in which the maximum compressive stress trends to the northwest (Yang and Aggarwal, 1981); proximity to relatively young igneous bodies (McKeown, 1978); the response of the crust to glacial unloading (Stein and others, 1979); and, in the immediate region about the site, proposed reactivation of pre-existing fault zones based on a spatial correlation with surface traces of faults exposed within the region (Aggarwal and Sykes, 1978).
Earthquakes occurring near Indian Point have been characterized as shallow focus (<10 km) and low magnitude (1.0-3.0) (Aggarwal and Sykes, 1978). Focal mechanism solutions reported for earthquakes near the Ramapo fault or the margins of the Triassic basin indicate thrust movement on faults that parallel the dominant structural grain in the exposed bedrock (Figure 2) (Aggarwal and Sykes, 1978; Yang and Aggarwal, 1981).
The stress field required for this interpretation, must be compressional and oriented to the northwest (Yang and Aggarwal, 1981). Whereas some of the seismic activity in southern New York may be related to northeast trending structures, a number of other trends, transversely oriented with respect to the dominant structures are present (Ratcliffe, 1976; Pomeroy et al, 1976; Blackford and Statton, 1978; Quarterly Report for the Indian Point Seismic Monitoring Network, November 1979 through January 1980)
(see Figure 2). Thompson and Bebel (1979) describe northeast and northwest trends of epicenters in the coastal plain area of New Jersey, Delaware and Pennsylvania.
Many studies have attempted to quantify the stress regimes operating in the vicinity of the Ramapo fault. Dames and Moore (1977) determined the near surface stress by in-site measurements. While these results are variable, a fairly consistent northeast to eastwest trend for the horizontal component of compression was determined. This stress direction is transverse to that suggested by others (Aggarwal & Sykes, 1978) who base their interpretations on reported focal mechanism solutions. It is, however, in general agreement with regional stresses inferred from measurements and observations made throughout the northeastern United States (Sbar and Sykes, 1973).
An examination of the distribution of earthquakes in the vicinity of Indian Point indicates that not all earthquakes in the region can be attributed to northeast trending faults. A sequence of earthquakes occurred near Annsville, New York, from 17 January to 23 January 1980. A composite focal mechanism solution was constructed using data recorded by the Indian Point Seismic Monitoring Network. The solution indicates thrust faulting along one of two possible planes, oriented N2°W 29°E or N16°W 62°W (Quarterly Report for the Indian Point Seismic Monitoring Network, November 1979 - January 1980). This trend is obliquely oriented to the dominant structural fabric in the region, and requires a compressive stress field oriented east-west to northeast-southwest.
Low level microseismicity existing in the region is evidence that crustal adjustments are continuing in response to regional stresses. No evidence exists at the surface or in drill cores of the fault zones (in particular the Ramapo fault zone), that suggest any contemporary movement along faults exposed at the surface since the major period of activity during Mesozoic time. In fact geologic data obtained from cores of the Ramapo fault zone (Ratcliffe, 1980) show evidence of normal faulting as the last movement, which is consistent with the Mesozoic faulting regime and inconsistent with the thrust mechanism proposed by Aggarwal and Sykes (1978). To date, no satisfactory stress
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-118 of 2-123 Revision 0, 2020 regime has been proposed that adequately accommodates the observed pattern of low level seismicity, regional stress measurement data and those stresses inferred from recently reported focal mechanism solutions.
CONCLUSION Low level microseismicity in the region is evidence that crustal adjustments are continuing in response to regional stresses. Detailed field investigations (e.g., Ratcliffe, 1976, 1980; Dames and Moore, 1977) have been conducted in the immediate vicinity of Indian Point, and along the major faults in the region. To date, no evidence has been found in the rocks exposed at the surface or sediments overlying fault traces or in cores obtained in the vicinity of Indian Point, that might support a conclusion that displacement has occurred along major fault systems within the New York Highlands, the Ramapo or its associated branches during Quaternary time (the last 1.5 m.y.). In the vicinity of Indian Point, evidence that no displacement has occurred in the last 65 m.y.
(since the Mesozoic) along specific major structures has been observed.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-119 of 2-123 Revision 0, 2020 Aggarwal, Y.P., and Sykes, L.R., 1978, Earthquakes, faults and nuclear power plants in southern New York and northern New Jersey: Science, v. 200, p. 425-429.
American Geological Institute, 1977, Glossary of Geology, Gary, M., McAfee, R. Jr., and Wolf, C.L. eds., Am. Geol. Inst., Falls Church, Va., 805 p.
Blackford, M., and Statton, C. T., 1978, The Annsville, New York earthquake of September 2, 1977. Presented at the seventy-third annual meeting of the Seismological Society of America.
Brock, P.W.G., Structural and age relationships within the New York City Group in southeastern New York, Unpublished Grant Proposal.
Brock, P.W.G., and Mose, D.G., 1979, Taconic and younger deformation and metamorphism in the Croton Falls area, southeastern New York: Bull. Geol. Soc.
Am., Pt. II, v. 90, p. 1158-1195.
Dames & Moore, 1977, Geotechnical investigation of the Ramapo Fault System in the region of the Indian Point Generating Station.
Hall, L.M., 1968, Times of origin and deformation of bedrock in the Manhattan Prong, in:
Zen, White, Hadley and Thompson, eds., Studies of Appalachian Geology, Northern and Maritime, Interscience Publishers, New York, p. 117-128.
Heleneck, H.L. and Mose, D.G., 1978, Geology and geochronology of Precambrian rocks in the Lake Carmel region, Hudson Highlands, New York: Geol. Soc. Am.,
Abstracts with Programs, v. 10, no. 2, p. 47.
Heleneck, H.L. and Mose D.G., 1976, Structure, petrology and geochronology of the Precambrian rocks in the Central Hudson Highlands; in: Johnson, J.H., ed.,
Guidebook to Field Excursions, 48th Annual Meeting of the New York State Geological Association: New York, Vassar College, p. B1 1-27.
Mc Keown, F.H., 1978, Hypothesis: Many earthquakes in the central and southeastern United States are casually related to mafic intrusive bodies: Jour. Res. U.S. Geol.
Surv., v. 6, p. 41-50.
Merrill, F.J., 1896, The geology of the crystalline rocks of southeastern New York: New York State Museum. Ann. Rpt. No. 50, Appendix A., p. 21-31 Mose, D.G. and Hall, L.M., 1979, Rb-Sr whole-rock age determination of Member C of the Manhattan Schist and its bearing on allochthony in the Manhattan Prong, southeastern New York: Geol. Soc. Am., Abstracts with Programs, V. 11, no. 1,
- p. 46.
Nelson, S., 1980, Determination of Holocene fault movement along the Ramapo Fault in southeastern New York using pollen stratigraphy: Geol. Soc. Am., Abstracts with Programs, v. 12, no. 2, p. 75.
Pomeroy, P.W., Simpson, D.W., and Sbar, M.L., 1976, Earthquakes triggered by surface quarrying-the Wappingers Falls, New York sequence of June, 1974: Bull. Seis.
Soc. Am. V. 66, p. 685-700.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-120 of 2-123 Revision 0, 2020 Ratcliffe, N.M., 1976, Final Report on major fault systems in the vicinity of Tomkins Cove-Buchanan, New York: Report for Consolidated Edison Company, Inc. of New York, 157 p.
Ratcliffe, N.M., 1980, Brittle faults (Ramapo Fault) and phyllonitic ductile shear zones in the basement rocks of the Ramapo seismic zone, New York and New Jersey, and their relationship to current seismicity, in: Manspeizer, W., ed., Field Studies of New Jersey Geology and Guide to Field Trips, 52nd Annual Meeting of the New York State Geological Association, Newark, N.J., Rutgers University, p. 278-312.
Robinson, P., and Hall, L.M., 1979, Tectonic synthesis of southern New England in: The Caledonides in the USA, I.G.C.P., 1979. Blacksburg, Va.
Sbar, M.L., and Sykes, L.R., 1973, Contemporary compressive stress and seismicity in eastern North America: An example of intra-plate tectonics: Bull. Geol. Soc.
Am., v. 84, p. 1861-1882.
Stein, S., Sleep, S., Geller, R.J., Wang, S-C, and Krueger, G.C., 1979, Earthquakes along the passive margin of eastern Canada: Geophys. Res. Letts. v.6, p. 537-540.
Thompson, A.M., and Bebel, D.J., 1980, Modern seismicity in the middle Atlantic Seaboard Region, and some neotectonic Implications: Geol. Soc. Am., Abstracts with Programs, v. 12, no. 2, p. 55.
Woodward-Clyde Consultants, Quarterly Reports for the Indian Point Seismic Monitoring Network, Jan., 1977-Jan., 1982.
Yang, J-P, and Aggarwal, Y.P., 1981, Seismotectonics of northeastern United States and adjacent Canada. Jour. Geophys. Res., v. 86, p. 4981-4998.
In addition, the following reports were used as background information:
Fluhr, T.W., 1965, Memorandum on geologic features of Indian Point Nuclear Power Plant site: for Consolidated Edison Company of New York, Inc., 9 p.
Paige, S., 1955, A geologic report on the Indian Point Power House Site of the Consolidated Edison Company, Inc., New York.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-121 of 2-123 Revision 0, 2020 GLOSSARY amphibole - A complex chain silicate mineral rich in iron and magnesium.
amphibolite - A metamorphic rock whose main components are amphibole and plagioclase feldspar amphibolite facies - Rocks formed at moderate temperature and pressure conditions during regional metamorphism.
angular unconformity - An unconformity recognizable by the deposition of sediments over deformed rocks.
argillite - A compact mudstone, generally not laminated and not fissile.
arkose - A feldspar rich, generally coarse grained, sandstone derived from continental rocks.
breccia - A generally coarse grained rock composed of angular or broken fragments of rock, which may be formed tectonically in a fault zone, or by sedimentary processes.
brittle deformation - A term used to describe faulting and fracturing of rocks.
calc-silicate - A descriptive term applied to minerals or rocks consisting of calcium bearing silicates, such as diopside.
chlorite - A green iron-magnesium rich platy mineral.
chlorite grade metamorphism - Low-grade regional metamorphism indicated by the first appearance of chlorite in rocks of appropriate composition.
dike - An igneous intrusion that cuts across planar features of a rock.
disconformity - A break in the time-stratigraphic record separating two sequences of rock, both of which are bedded parallel to the unconformity.
ductile deformation - Occurs where rocks fold or flow when subjected to a stress field.
eugeosyncline - A geosyncline or basin in which vulcanism is associated with clastic sedimentation.
euhedral - A crystal bounded by well developed crystal faces.
facies - A set of conditions that specify the environment of formation of rocks (metamorphic or sedimentary).
geosyncline - A long linear basin, characterized by subsidence coincidental with sedimentation.
geothermal gradient - The relationship of temperature to depth (pressure) in the earths crust.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-122 of 2-123 Revision 0, 2020 gneiss - A metamorphic rock formed by regional metamorphism, generally high grade.
granulite facies - Rocks formed at very high temperatures and pressures during regional metamorphism.
intrusion - The emplacement of an igneous body in a pre-existing rock.
isocinal folds - A fold in which the limbs are parallel.
mafic - A term used to describe dark rocks or minerals containing large amounts of magnesium or iron.
marble - A metamorphic rock consisting primarily of calcite or dolomite.
metamorphic grade - Rocks of any composition that have been metamorphosed under a specific range of temperature and pressure conditions.
metasediment - A metamorphosed sedimentary rock.
migmatite - A mixed rock composed of metamorphic material containing segregation of igneous material formed by injection or in-situ partial melting.
miogeosyncline - A geosyncline lacking volcanic deposits, commonly located adjacent to continental margins.
neotectonics - Post-Miocene structural history of the earths crust.
orogen - A region that has been subjected to orogeny.
orogeny - The development of structures, metamorphism and igneous activity relating to mountain building.
pelite - A sedimentary or metamorphic rock rich in aluminum.
quartzite - A metamorphic or sedimentary rock consisting mainly of quartz.
retrograde metamorphism - Recrystallization of metamorphic rocks at conditions that are lower grade than those at which the rock was originally metamorphosed.
schist - A well foliated metamorphic rock that easily separates into flakes or slabs due to an abundance of platy minerals.
sedimentary facies - An restricted area within a litho-stratigraphic unit representing a particular depositional environment.
sill - An igneous intrusion that parallels the layering of the country rock.
tectonic - Pertaining to the forces that cause crustal deformation.
throw - The vertical component of fault motion.
unconformity - A primary feature representing erosion or non-deposition, resulting in a break in the stratigraphic sequence.
IP2 DEFUELED SAFETY ANALYSIS REPORT Page 2-123 of 2-123 Revision 0, 2020 TABLE 1 GEOLOGICAL TIME SCALE TABLE 2 PROPOSED CORRELATION OF THE STRATIGRAPHIC SUBDIVISIONS IN THE MANHATTAN PRONG WITH ROCKS IN ADJACENT AREAS TABLE 3 GEOLOGIC HISTORY IN THE CROTON FALLS AREA (after Brock & Mose, 1979)
FIGURES Figure No.
Title Figure 1 Geological Map, Southeastern New York (after Brock & Mose, 1979)
Figure 2 Seismicity of Southeastern New York and New Jersey (after Dames &
Moore, 1977)