ATTACHMENT Consumers Power Company Big Rock' Point Plant Docket 50-155 SEMIANNUAL RADI0 ACTIVE EFFLUENT RELEASE AND k'ASTE DISPOSAL REPORT JANUARY THROUGH JUNE 1989 August 31, 1989 g9o9050052 890830 ADOCK0500g((.
FDR R
OC0889-0011-NLO2
1 y.
s
- ye
~To TCBordine, P24-608 From WLBeckman CONSUMERS
$U$ 2 8 POWER Date August 17, 1989 COMPANY Subject BIC ROCK POINT-UNING Internal SEMIANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT Correspondence JANUARY-JUNE 1989 CC JLBeer, Big Rock TAHancock, Big Rock WLB89*060 Effluent File-RMC Tech (2)
DCC: 740/22*07*01*02/LP
. Attached please find the subject rcport prepared and reviewed in accordance with Palisades Procedure HP 10.3.
This report is believed accurate, pertinent and complete to the best of our ability in meeting the requirements of 10 CFR 50.36a and Technical Specification Section 6.9.2.2.
The Big Rock Point Radioactive Effluent Release Report was prepared by JTBroda/JHager/MAMoore, RMC Radiological Services Department with technical review assigned to TPNeal, RMC.hininistrator. Administrative review and, report approval was done by WLBeckman, Radiological Services Manager.
Report prepared by:
W JHager/JTBroda/MAMoore, Nuclear 0;krationg Analfst/RMC Support Date Technical Review performed by:
Yf TPNeal, RMC Administrator Date Administrative Review and Report approval by:
WLBeckman, Iddiptogical Services Manager Date l
l IC0889-0192A-HP01 a.
.o s
s Big Rock Point Semiannual Radioactive Efiluent Release Report January - June 1989 This report provides information relating to the radioactive ef fluent releases und solid radioactive waste disposal operations of Big Rock Point during the period of January - June 1989. Format for this report'is contained in Technical Specification 6.9.2.2.
Big Rock Point was online for most of the first and second quarters. On June 10th, Big Rock Point was taken out of service for a scheduled refueling / maintenance outage.
1.
Supplemental Information A.
Batch Releases Information relating to continuous and batch releases of gaseous and liquid ef fluents is provided in Table HP 10.3-1.
B.
Abnormal Releases None.
2.
Caseous Effluents Table HP 10.3-2 lists and summarizes all gaseous radioactive effluents released during the reporting period. The unidentified beta was 5.62E-01% of the total (particulate) release. The maximum noble gas release rate for the first and second quarters was 3.25E+02 and 2.88E+02 pCi/second,respectively.
3.
Q uid Efflucets Table HP 10.3-3 lists and summarizes all liquid radioactive effluents released during the reporting period. The unidentified beta was 7.88% of the total release. The maximum liquid effluent release concentration for the first and second quarters was 3.41E-07 and 1.03E-06 pCi/ml, respec-tively.
1 4.
Solid Radioactive Was?e Eolid radwaste classification sources, volume shlpped, curie and nuclide content are detailed in Table HP 10.3-4.
Radwaste shipments were processed and sent to Barnwell, South Carolina for burial.
5.
Summarv of Radiological Impact on Man Potential doses to individuals and populations were calculated using CASPAR and LADTAP computer program codes. The first and second querter values for curies released were input for each nuclide and summarized as follows:
A.
The maximum offsite air doses due to noble gases was during the first quarter. Doses at the site boundary (.57 mi E) were 1.10E-02 millirad beta and 1.95E-02 millirad gamma. Doses at the nearest I C0889-0192 A-HP01 1
lo' a-
?
s c
g residence / garden'(1.40 1:i E) were 1.31E-02 millirad beta and n
2.33E-02 millirad gamma.
l B.
The most restrictive organ dose to an individual in an unrestricted area (based on identified critical receptors) from gaseous effluents l.
(tritium, particulate, and iodines) was the infant thyroid far both l-the first and recond quarters. Doses were 1.84E-03 millirca and L.
2.16E-03 millirem, respectively, m
C.
The maximum total body dose to individuals (adult) in unrestricted water related exposure pathways was 2.46E-02 millirem for the first
?
quarter and 2.27E-02 millirem for the second quartar. The maximum l:
organ dose was the child bone for the first quarter and the adult
~
i bene,for the second quarter. Doses were 4.41E-02 millirem and 4.49E-02. millirem, respectively.
D.
Integrated total body dose to t:ae general population and average dose to individuals within the population from liquid effluent releases within a distance of 50 miles from the site boundary were:
1,18E-02 manRem and 7.66E-05 millirem for the first quarter; and 11.29E-02 manRem and 8.38E-05 millirem for the second quarter.
E.
Integrated total. body dose to the general population and average dose to individuals within the population from gaseous effluent releases within a distance of 50 miles from the site boundary were:
1.29E-02 manRem and 8.38E-05 millirem for the first quarter; and 1.02E-02 manRem and 6.62E-05 millirem for the second quarter.
j F.
There was no entrained noble gas present in either the first or second quarter liquid releases.
6.
There were no changes to the PCP during this reporting period.
7.
Offsite Dose Calculation Manual (ODCM)
The ODCM has undergone a technical revision and is attached in it's entirety.
IC0889-0192A-HP01 2
..a s
TABLE HP 10.3-1 BIC ROCK POINT SEMIANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT BATCH RELEASES JANUARY 1989 to JUNE 1989 A.
Caseous - Continuous Release B.
LIQUID 1st Quarter 2nd Quarter Number of Releases 7
10 Total Release Time Minutes 1.76E+03 1.34E+03 Maximum Release Time Minutes 6.80E+02 2.05E+02 Average Release Time Minutes 2.51E+02 1.33E+02 Minimu:n Release Time Minutes 1.29E+02 2.00E+01 IC0889-0192A-HP01 3
_a,___.m._____m. - _ _ _ _ -. -. - - - - - - - - - - - - - - -
J 0
s TABLE HP 10.3-2 BIC ROCK POINT SEMI ANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT CASEOUS EFFLJENTS - SUMMATION OF RELEASES JANUARY 1989 to JUNE 1989 Est Total A.
FISSION AND ACTIVATION CASES UNITS ist QUARTER 2nd QUARTER Error %
1.
Total release Ci 2.42E+03 1.78E+03 2.
Average release rate for period uCi/sec 3.11E+02
- 2. 26 E+ 02 5.5 3.
Percent of annual avg MPC 8.59E-02 6.27E-02
, B.
IODINES 1.
Total Iodine Ci 4.46E-03
- 4. 70 E-03 2.
Average release rate for period
- uCi/sec
- 5. 74 E-04 5.98E-04 5.6 3.
Percent of annual ave irc 1.80E-05 1.94E-5 C.
PARTICitLATES 1.
Particulate with half-life >
8 days Ci 8.29E-04 3.61E-04 2.
Average release rate for period uCi/see 1.07E-04 4.60E-05~~
3.
Percent of annual ava MPC 1.14E-06 1.23E-06 18.7
- 4.
Cross alpha radioactivity Ci 4.45E-07 1.42E-06 5.
Cross alpha release rate for period uCi/see 5.72E-08 1.81E-07 D.
TRITIUM 1.
Total release Ci 1.31E+00 1.29E+00 2.
Average release rate for period uCi/see 1.68E-01 1.64E-01 3.
Percent of annual avg MPC 7.65E-06 7.46E-06 E.
1.
Beta air dose at site boundary due to Noble Cases (TS 13.1.4.2a) mRads 1.10E-02 8.12E-03 2.
Percent limit 1.1E-01 8.12 E- 02 3.
Camma air dose at site boundary due to Noble Cases (TS 13.1.4.2a) mRads 1.95E-02 1.42E-02 4.
Percent limit I
3.90E-01 2.84E-01 F.
1.
Maximum organ dose to public based based on critical receptors (TS 13.1.4.3a) mrem 1.84E-03 2.16E-03 2.
Percent of limit I
2.45E-02 2.88E-02
- Note:
Data is reported for I-131 and 1-133 only IC0889-0192A-HP01 4
b e; E
r TABLE HP 10.3-2 4
BIC ROCK POINT SEMIANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT CASEOUS EFFLUENTS JANUARY 1989 to JUNE 1989 1..
FISSION CASES Units
- 1st QUARTER 2nd QUARTER Krypton-85m Ci 3.48E+01 2.79E+01
-Krypton-87 Cl 1.70E+02 1.36E+02
- , \\
-Krypton-88 Ci 1.08E+02
'8.80E+01 Xenon-133 Ci 1.45E+01 1.15E+01 Xenon-133m Ci None Wone Xenon-135 Ci 1.68E+02 1.33E+02 XenoU-135m Ci 2.78E+02 2.02E+02 Xenon-138 Ci 1.16E+03 8.20E+02 Nitrogen-13 Ci 4.83E+02 3.62E+02 Total for Period Ci 2.42E603 1.78E+03 2.-
IODINES Iodine-131 Ci 5.63E-04 6.67E-04 Iodine-132 Ci None None Iodine 133 Ci 3.90E-03 4.03E-03 Iodine 134 Ci None None Iodine-135 Ci None None Total for Period Ci 4.46E-03 4.70E-03 l
l
'IC0889-0192A-HP01 5
t.
s.L gj,.
4 TABLE HP 10.3-2 BIC ROCK POINT SEMIANNUAL RADI0 ACTIVE EFFLUENT RELEASE REPORT CASEOUS EFFLUENTS JANUARY 1989 to JUNE 1989-3.
PARTIC!ILATES*
Units let QUARTER 2nd QUARTER Chromium-51 Ci 3.88E-04' 9.60E-05 Manganese-54 Ci 3.36E-05 2.64E-05 Cobalt-58 Ci 2.22E-06 None Bari um-140 Ci 1.36E-04 9.10E-05 Cob 41t-60 Ci 6.14E-05 3.76E-05 Zine-65 Ci 5.48E-06 7.52E-06 Niobium-95 Ci 2.51E-07 None Cesium-134 Ci 4.83E-05 5.30E-06 Cesium-137 Ci 7.64E-05 4.56E-05 Iron-59 Ci 1.68E-05 None Silver-110m Ci 1.73E-05 6.7E-06 Lanthanum-140**
Ci 4.14E-04 2.72E-04 Strontium-91**
-Ci 2.35E-04 None Bromine-82**
Ci 4.11E-04 2.99E-04 Sodium-24**
Ci 2.04E-04 7.30E-05 Molybdenum-99**
Ci 4.88E-05 2.29E-05 Str,ntium-89***
Ci 4.00E-05 2.74E-05 Strontium-90***
Ci 5.88E-07 3.25E-06 Net. unidentified beta Ci 3.20E-06 1.46E-05 Total Ci 2.14E-03 1.03E-03 Particulate with half-lives >B days.
Particulate with half-lives (8 days; not reflected in overall isotopic totals.
- Calculated from vendor analysis of monthly stack gas filters. Reported vendor cnalyzed Sr 89/90'results were input to CASPAR code as Sr90 to yield conservative dose estimates.
IC0889-0192A-HP01 6
(f#
~
- e
.~
- TABLE HP 10.3-3.
BIG ROCK POINT SEMIANNUAL RADIOACTIVE EFFLUENT RELEASE REPORT LIQUID EFFLUENTS - SUMMATION OF RELEASES JANUARY 1989 to JUNE 1989 Est Total A.
FISSION'AND ACTIVATION PRODUCTS UNITS 1st QUARTER 2nd QUARTER Error %
1.
Total. release (not including tritium, gases, alpha)
Ci 2.82E-02 3.76E-02
- 2.. Average diluted concentration during period uci/ml 1.37E-09 1.81E-09 5.0 3.
Percent of MPC Y
1.62E-02
- 2.,1 ? E-02 B.
TRITIUM 1.-
Total release Ci 8.88E-02 4.26E-02 2.
Average diluted concentration during period uCi/ml 4.31E-09 2.05E-09 6.39 3.
Percent of MPC 1.44E-04 6.83E-05 C. - DISSOLVED AND ENTRAINED CASES 1.
Total Release Ci None None 2.
Average diluted concentration during period uCi/ml None None None 3.
- D.
CROSS ALPHA RADIOACTIVITY (Total' Release)
Ci 1.18E-06 2.58E-06 1.
Average diluted concentration during period uCi/ml 5.73E-14 1.24E-13 E.
VOLUME OF WASTE RELEASED (Prior to Dilution)
Liters 1.17E+05 1.55E+05 F. - VOLUME OF DILUTION WATER USED DURING PERIOD Liters 2.06E+10 2.08E+10 C.
MAXIMUM DOSE COMMITMENT - WHOLEBODY mrem 2.46E-02 2.27E-02 Percent of TS 13.1.4.la limit 1.64E+00 1.51E+00 l~
l H.
MAXIMUM DOSE COMMITMENT - ORGAN mrem 4.41E-02 4.49E-02 Percent of TS 13.1.4.la limit 8.82E-01 8.98E-01 IC0889-0192A-HP01 7
\\
e TABLE HP 10.3-3 BIG ROCK POINT SEMIAN'4UAL RADIOACTIVE EFFLUENT RELEASE REPORT LIQUID EFFLUENTS JANUARY 1989 to JUNE 1989 1.
NUCLIDES RELEASED Units 1st QUARTER 2nd QUARTER Cesium-137 Ci 8.23E-03 4.77E-03 Cobal+-58 Ci None 8.53E-05 Manganese-54 Ci 5.52E-03 7.98E-03 Cobalt-60 Ci 6.43E-03 1.14E-02 Cesium-134 Ci 4.40E-04 1.27E-03 Iron-59 Ci 4.03E-04 1.30E-03 Zine-65 Ci 3.14E-04 1.28E-04 Mol ybd enum-99 Ci None 6.85E-05 Chromium-51 Ci None 1.21E-03 Silver-110m Ci 6.74E-05 1.21E-04 Stontium-92 Ci 1.25E-05 None Strontium-89**
Ci 2.49E-05 1.56E-04 Strontium-90**
Ci 1.15E-04 1.55E-04 Net Unidentified Beta Ci 6.61E-03 8.94E-03 Fission & Activation Product Total (Above)
Ci 2.82E-02 3.76E-02 Xenon-133 Ci None None Tritium Ci 8.88E-02 4.26E-02 Crand Total Ci 1.17E-01 8.02E-02 Calculated from vendor analysis of monthly radwaste composite samples.
Reported net beta and vendor analyzed Sr 89/90 results were input to LADTAP code
]
as Sr-90 to yield conservative dose estimates.
I I
l IC0889-0192A-HPG1 8
L
' {..
TABLE HP 10.3-4 BIG ROCK POINT SEMIANNUAL RADI0 ACTIVE EFFLUENT RELEASE REPORT SOLID RADIOACTIVE WASTE JANUARY 1989 to JUNE 1989 Wsste '
Source of Solidification Container Volume
- Total
- Principal Cims Waste Agent Type (cu ft)
Curies Radionuclides C.
Dewatered N/A HIC 1.94E+02 1.40E+01 Cs-137,Co-60,Mn-54 Filters Ni-63,C-14,Fe-55 C
Dewatered N/A HIC 8.3E+01 8.59E+01 Fe-55,Co-60,Mn-54, Filters Cs-137,Ni-63,C-14
- NOTE: Total curies are estimated (sealing factors used) 00 NOTE: Gamma isotopes are measured quantities; all other isotopes are estimated.
OC0889-0011-NLO2 9
,