Text

..

TEST NUMBER 8276

_ g._

Independent s Textile tea $

Service,Inc.

P.O. Box 1948 /1503 Murray Avenue Dalton, Georgia 30722-1948 / Phone 404-278 3013 REPORT CUSTOMER:

BOSTON EPISON MARCH 4, 1987

SUBJECT:

Specimens of the submitted samples were prepared and tested in accordance with ASTM E-648 and/or Federal Test Method 372. NFPA 253 FLOORING RADIANT PANEL TEST Sample Description Style:

PATTERN:

L8203 Color:

363 Roll No.:

DYE LOT M 18261 Fiber:

Pile:

I Secondary Backing:

Burlington's pressure sensitive adhesive was used to give Test Assembly :

i the carpet, described above, directly to 1/4 inch asbestos /

1 (SAME AS TEST # 8273) ement board for testing.

Test Results Specimen No.1 Specimen No. 2 Specimen No.3 Critical Radiant Flux:

.77 watts /cm2

,94 watts /cm2

,73 watts /cm2 Total Burn Length:

26.0 cm.

16.0 cm.

27.0 cm.

Flame Front Out:

28.0 minutes 7g,o minutes 26.0 minutes Average Critical Radiant Flux:

.82 watts /cm2 Estimated Standard Deviation

,ig watts /cm2 n

12%

coefficient of variation 0 tc enla NOTE: SOME SEPARATION OF PRIMARY BACKING FROM SECONDARY OCCURED DURING TESTING DU o'

TO MELTING OF PREC0AT LAMINATE.

N oc w

r (0/)T4)

c Do Authorized Sigpre

[]

ok INDEPENDENT TEXTu.E TESTING SERVICE, INC.

d O

our setters and reports are for the exclusive use of the customer to whom.they are addressed. and their communication to any others or the use of tne occ name of independent Text <ie Testeng service. Inc. must receive our poor wntten approvat oar 6etters and reports apply only to the sample tested and O

are not necessaniy indicative of the cualities of apparently identicai or similar products The reports and setters and tne name of the independent g Textise Testing service. Inc.. are not to be used under any circumstances in advertising to the general public

}-400 J

  • .