Letter Sequence Approval |
|---|
|
|
MONTHYEARML20096C9121984-08-0606 August 1984 Requests Extension to 841215 for Response to Generic Ltr 84-15 Re Diesel Generator Reliability.Extension Requested Due to Manpower Constraints,Time Needed to Collect,Verify & Analyze Data & Time Required to Formulate Future Actions Project stage: Other ML20101N6601984-12-28028 December 1984 Forwards Response to 840702 Generic Ltr 84-15 Re Reduction in Number of Cold Fast Starts Surveillance Tests for Diesel Generators & Diesel Generator Reliability Data Project stage: Other ML20101S5361985-01-28028 January 1985 Forwards Revised Pages to 841228 Response to Generic Ltr 84-15 Re Diesel Generator Reliability Data.Revised List of Failures & Causes of Failures for Each Diesel Generator for Last 20 & 100 Demands Encl Project stage: Other ML20101R8571985-01-31031 January 1985 Informs That Diesel Generator Reliability Info Submitted in in Response to Generic Ltr 84-15 Precludes Separate Response to Generic Ltr 83-41 Re Fast Cold Starts of Diesel Generators Project stage: Other ML20134A1321985-10-25025 October 1985 Advises of Review of Tech Specs & Intent to Prepare Application for Amend in Response to Generic Ltr 84-15 Re Diesel Generator Reliability.Schedule Discussed W/Nrc Project Manager on 851008 Project stage: Request ML20140F8511986-03-21021 March 1986 Proposed Tech Spec Sections 2 & 3 Incorporating Surveillance Requirements for Solid Radwaste.Discussion,Justification & Significant Hazards Consideration Encl Project stage: Other ML20140F8391986-03-21021 March 1986 Application for Amend to License DPR-40,changing Sections 2 & 3 of Tech Specs to Incorporate Surveillance Requirements for Solid Radwaste Project stage: Request ML20140F8161986-03-28028 March 1986 Forwards Application for Amend to License DPR-40,changing Sections 2 & 3 of Tech Specs to Incorporate Surveillance Requirements for Solid Radwaste.Certificate of Svc Encl. Fee Paid Project stage: Request ML20205M3801986-04-0909 April 1986 Application for Amend to License DPR-40,revising Tech Specs Re Surveillance Requirements for Emergency Diesel Generator Project stage: Request ML20205M3641986-04-0909 April 1986 Forwards Application for Amend to License DPR-40,revising Tech Specs,Re Surveillance Requirements for Emergency Diesel Generators Project stage: Request ML20207S1161987-03-13013 March 1987 Forwards Response to Questions Raised on 860321 Application for Amend to License DPR-40 Re Testing of Emergency Diesel Generators to Complete Generic Ltr 84-15 Actions Project stage: Request ML20216D0571987-06-22022 June 1987 Proposed Tech Specs Re Deletion of Requirement to Start Diesel Engine Project stage: Other ML20216D0271987-06-22022 June 1987 Update to 860321 Application for Amend to License DPR-40, Incorporating Discussion,Justification & Significant Hazards Considerations Re Deletion of Requirement to Start Diesel Engine Project stage: Request ML20235G8961987-09-24024 September 1987 Safety Evaluation Supporting Amend 111 to License DPR-40 Project stage: Approval ML20235G8881987-09-24024 September 1987 Amend 111 to License DPR-40,incorporating Revised Surveillance Requirements for Diesel Generators Into Tech Specs,Per Generic Ltr 84-15, Proposed Staff Actions to Improve & Maintain Diesel Generator Reliability Project stage: Other ML20235G8721987-09-24024 September 1987 Forwards Amend 111 to License DPR-40 & Safety Evaluation. Amend Incorporates Revised Surveillance Requirements for Diesel Generators Into Tech Specs,Per Generic Ltr 84-15, Proposed Staff Actions..., Per Util 860328 Request Project stage: Approval 1986-03-21
[Table View] |
Text
_
September 24, 1987 Docket No. 50-285 Mr. R. L. Andrews Division Manager - Nuclear Production Omaha Public Power District 1623 Harney Street Omaha, Nebraska 68102
Dear Mr. Andrews:
SUBJECT:
ISSUANCE OF AMENDMENT NO.111 TO FACILITY OPERATING LICENSE NO.
DPR FORT CALHOUN STATION, Uh7T N0. 1 (TAC N0. 55860)
The Commission has issued the enclosed Amendment No.111 to Facility Operating License No. DPR-40 for the Fort Calhoun Station, Unit No. 1.
This amendment consists of changes to the Technical Specifications in response to your application dated March 28, 1986, as supplemented April 3, 1986, March 13 and June 22,'1987.
The amendment incorporates revised Surveillance;Requirerrents for the diesel
~
generators in accordance with Generic Letter 84-15 entitled, " Proposed Staff Actions to Improve and Maintain Diesel Generator Reliability."
A copy of the Safety Evaluation is also enclosed.
The notice of issuance will be included in the Commission's next regular bi-weekly Federal Register notice.
Sincerely, i
Anthony Bournia, Project Manager Project Directorate - IV i
Division of Reactor Projects - III, IV, V and Special Projects Office of Nuclear Reactor Regulation
Enclosures:
1.
Amendment No.lli to DPR-40 2.
Safety Evaluation cc w/ enclosures:
g7993OO270 870924 ADOCK0500g5 See next,.page PDR DIST UTION:
U)6cket File DHagan Wanda Jones OGC-Bethesda Fort Calhoun File NRC PDR PNoonan (3)
EJordan EButcher Local PDR ABournia JPartlow ACRS (10)
PD4 Reading JCalvo ARM /LFMB TBarnhart (4)
- 0. Chopra
[
l LTR NAME: FORT CALHOUN AMENDMENT 55860 09 PD4/L,AQl{'
PD4/PM Og-Belesda PD4/D /?/C PNoonan /
ABournia JCalvo 09/fl/87 09/h /87 09
/87 09/1y/87 0FF CIAL RECORD COPY C-
7 Fort Calhoun Station Mr. R. L. Andrews Unit No. 1 Omaha Public Power District' l
l CC:
Harry H. Voigt, Esq.
.LeBoeuf,. Lamb,' Leiby & MacRae 1333 New Hampshire' Avenue, NW Washington, D.C.
20036 Mr. Jack'Jensen, Chairman Washington County. Board of Supervisors Blair, Nebraska 68008 Mr. Phillip Harrell, Resident Inspector U.S. Nuclear Regulatory Commission P. O. Box.309 Fort Calhoun, Nebraska 68023
~
Mr. Charles B. Brink, nan, Manager Washington Nuclear Operations
.C-E Power Systems
'7910 Woodmont' Avenue Bethesda, Maryland' 20814 Regional Administrator, Region IV' U.S. Nuclear Regulatory Commission Office of Executive Director for Operations 611 Ryan Plaza Drive Suite 1000 Arlington, Texas -76011 Harold Borchert, Director Division of Radiological Health Department of Health 1
3 301 Centennial Mall, South P.O. Box 95007 Lincoln, Nebraska 68509 W. G.. Gates, Manager Fort Calhoun Station P. O. Box 399 i
Fort Calhoun, Nebraska 68023 I
(
l-l l-L
)