QCCP 0100-16 UNIT 1(2)
REVISION 3 i
ATTACHMENT A (Page 1 of 5)
EFFLUENT & WASTE DISPOSABLE SEMI-ANNUAL REPORT GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES Period: January through June 1997 FIRST SECOND Est. Total A. FlSSION & ACTIVATION GASES UNIT QUARTER QUARTER Error %
- 1. Total Release Cl 6.27 3.07 12.4
- 2. Average release rate for the period ACf/sec 8.06E-01 3.90E-01
- 3.
- Percent of ODCM limit Chimney &
2.43E-03 1.18E-03 Stack 1.13E-04 5.39E 05 B. IODINE
- 1. Total todine-131 C1 2.32E-04 4.06E-05 40.0
- 2. Average release rate for the period kCi/sec 2.98E-05 5.16E-06 C. PARTICULATES
- 1. Particulates with half-lives >8 days Ci 2.14E-03 1.41E-03 30.1
- 2. Average release rate for the period gCi/sec 2.75E 04 1.79E-04
- 3. Gross alpha radioactivity Ci
<tLD
<LLD
- 0. TRITIUM
- 1. Total Release ci 2.57E+01 1.49E+01 8.0
- 2. Average release rate for the period gCl/see 3.31E00 1.89E00 E. lodine 131 & 133, Tritium & Particulate
- 1. Percent of ODCM timit Chimney & Stack 1.27E-01 2.14E-01
- NOBLE GAS GAMMA / NOBLE GAS BETA DOSE LIMITS l
9803240353 980313 PDR ADOCK 05000254 R
ppy CHDi/12QTR97 14
OCCP 0100-16 UNIT 1(2)
REVISION 3 ATTACHMENT A (Page 2 of 5)
EFFLUENT & WASTE DISPOSABLE SEMI-ANNUAL REPORT MAIN CHIMNEY GASEOUS EFFLUENTS CONTINUOUS MODE BATCH MODE NUCLIDES RELEASED FIRST SECOND
- 1. Fission gases UNIT GUARTER QUARTER QUARTER QUARTER Kr-85 Ci
<LLD
<LLD NA NA Kr-85m Cl 2.63E-01 2.15E-01 NA NA Kr-87 Cl 1.87E-01 7.27E 02 NA NA Kr-88 Ci 2.27E-01 1.33E 01 NA NA Xe-133 Cl 5.61E-01 3.62E-01 NA NA ye-135 Cl 1.66E-01 9.49E-02 NA NA Xe-135m Cl 9.27E 01 3.70E-01 NA NA Xe 138 Ci 3.81E00 1.53E00 NA NA Ar-41
' Cl 1.33E-01 2.95E-01 NA NA fotal for Period Ci 6.27E00 3.07E00 NA NA m
m NUCLIDES RELEASED FIRST SECOND
- 2. lodines UNIT QUARTER QUARTER QUARTER QUARTER I-131 Ci 2.32E-04 4.06E-05 NA NA I-133 Ci 6.51E 04 3.46E-04 NA NA I-135 Ci
<LLD
<LLD NA NA Total for period Ci 8.83E-04 3.87E-04 NA NA m
m..-
NUCLIDES RELEASED FIRST SECOND
- 3. Particulates UNIT QUARTER QUAPTER QUARTER QUARTER Sr-89
- Cl 8.43E-05 6.24E-05 NA NA Sr-90
- Ci
<LLD
<LLD NA NA Cs-134 C1 (LLD
<LLD NA NA Cs-137 Ci
<LLD
<LLD NA NA Ba 140 Ci
<LLD
<LLD NA NA La-140 Ci
<LLD
<tLD NA NA Cr-51 Ci
<LLD
<LLD NA NA Mn 54 Ci
<LLD
<LLD NA NA Co-58 Ci (LLD
<LLD NA NA Co-60 Cl 1.57E-04 1.70E 04 NA NA Mo 99 Ci
<LLD
<LLD NA NA Ap-110m Ci
<lLD
<LLD NA NA j
1-131 Ci (LLD
<tLD NA NA 1-133 Ci 8.79E-05 (LLD NA NA l
Total for Period Cl 3.29E-04 2.32E-04 NA NA
- Projected value based on previous six months data.
curm u otR,7 15
QCCP 0100-16 UNIT 1 (2)
REVISION 3 ATTACHMENT A (Page 3 of 5)
EFFLUENT & WASTE DISPOSABLE SEMI-ANNUAL REPORT REACTOR VENTILATION GASEOUS EFFLUENTS CONTINUOUS MODE BATCH MODE NUCLIDES RELEASED FIRST SECOND
- 1. Fission gases UNIT QUARTER QUARTER QUARTER QUARTER Kr-85 Ci
<tLD
<tLD NA NA Kr 85m Ci
<LLD (LLD NA NA Kr-87 Ci
<LLD
<LLD NA NA Kr-88 Ci
<LLD
<LLD NA NA Me 133 Ci
<LLD
<lLD NA XA Xe-135 Ci
<lLD
<tLD NA NA ye-135m Ci (LLD
<tLD NA NA Xe-138 Ci
<tLD
<tLD NA NA Total for Period Ci
<tLD
<tLD NA NA M
M NUCLIDES RELEASED FIRST SECOND
- 2. lodines UNIT QUARTER QUARTER QUARTER QUARTER l-131 Ci
<LLD
<LLD NA NA I-133 Ci
<LLD
<LLD NA NA 1 135 C1 (LLD (LLD WA NA Total for period Ci
<LLD
<tLD NA NA m
M NUCLIDES RELEASED FIRST SECOND
- 3. Particulates UNIT QUARTER DUARTER QUARTER QUARTER Sr-8's
- Ci
<tLD
<LLD NA NA Sr-90
- Ci
<tLD
<LLD NA NA Cs 134 Ci
<LLD
<LLD NA NA Cs-137 Cl 1.59E 05 2.51E 06 NA NA Ba 140 Ci
<LLD
<tLD NA NA La-140 Ci
<LLD
<LLD NA NA Cr-51 Ci 2.25E 04
<tLD NA NA Mn-54 Cl 8.79E-05 2.70E-04 NA NA Co-58 Ci
<LLD 1.87E-05 NA NA Co-60 Cl 1.48E-03 6.44E-04 NA NA Mo 99 Ci
<LLD 2.42E-04 NA NA Ag-110m Ci
<tLD (LLD NA NA 1 131 Ci
<LLD
<tLD NA NA I-133 Ci
<LLD
<LLD NA NA Total for Period Cl 1.81E-03 1.18E 03 NA NA
- Projected value based on previous six months data.
CHEM /22QTR97 16
QCCP 0100-16 UNIT 1(2)
REVISION 3 ATTACHMENT A (Page 4 of 5)
EFFLUENT & WASTE DISPOSABLE SEMI-ANNUAL REPORT LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES FIRST SECOND Est. Total A.
FISSION & ACTIVATION GASES UNIT QUARTER QUARTER Error %
- 1. Total Release (not including tritium, ci 1.09E-02 9.39E-03 5.6 gases & alpha)
- 2. Average diluted concentration during pCi/mL 2.10E-09 1.37E-09 batch discharges for the period 3.
Percent of applicable limit
- 2.72E-02 1.69E-03 1.29E-02 7.06E-04
- 4. Maximum diluted concentration during pCi/mL 7.98E-09 3.08E-09 batch discharges mmmmmmmmmmmmmmmemammmmmmmmmmmmmme -
B. TRITIUM l
- 1. Total Release Ci 5.84E00 8.29E00 4.0
- 2. Average diluted concentration during pCi/mL 1.13E-06 1.21E-06 batch discharges for the period 3.
Percent of applicable limit 3.76E-02 4.03E-02 C.
DISSOLVED & ENTRAINED GASES l
- 1. Total Release Ci
<LLD
<LLD NA
- 2. Average diluted concentration during pCi/mL
<LLD
<LLD batch discharges for the period plicable limit NA NA j
D.
GROSS ALPHA ACTIVITY
- 1. Total Release Ci
<LLD
<LLD NA
- 2. Average diluted concentration during pCi/mL
<LLD
<LLD batch discharges for the period E. VOLUME OF WASTE RELEASED (prior to Liters 1.82E+06 1.67E+06 dilution)
F. VOLUME OF DILUTION WATER USED Liters 5.18E+09 6.86E+09 DURING BATCH DISCHARGES l
G.
TOTAL VOLUME OF DILUTION Liters 2.64E+11 3.10E+11 WATER USED DURING PERIOD (quarter)
]
1 I
o Whole Body / Organ (ODCM)
CHEM /120TR97 17
OccP 0100-16 UNIT 1(2)
REVISION 3 ATTACHMENT A (Page 5 of 5) 1 EFFLUENT & WASTE DISPOSABLE SEMI-ANNUAL REPORT LIQUID EFFLUENTS CONTINUOUS MODE BATCH MODE FIRST SECOND FIRST SECOND NUCLIDES RELEASED UNIT QUARTER QUARTER QUARTER QUARTER Sr-89 Ci
<LLD
<LLD
<LLD 3.63E-05 Sr-90 Ci.
<LLD
<LLD 1.98E-04 3.84E-06 Cs-134 Ci
<LLD
<LLD
<LLD
<LLD Cs-137 Ci
<LLD
<LLD 6.67E-03 2.56E-04 I-131 Ci
<LLD
<LLD
<LLD
<LLD Co-60 Ci
<LLD
<LLD 3.13E-03 5.17E-03 Co-58 Ci
<LLD
<LLD 1.41E-05 2.21E-04 Fe-59 Ci
<LLD
<LLD
<LLD 6.95E-05
]
f Zn-65 Ci
<LLD
<LLD
<LLD
<LLD i
Mn-54 Ci
<LLD
<LLD 3.94E-04 8.26E-04 j
Cr-51 Ci
<LLD
<LLD 2.83E-04 2.56E-03 Zr-95 Ci
<LLD
<LLD
<LLD
<LLD Nb-95 Ci
<LLD
<LLD
<LLD
<LLD 1
)
Mo-99 Ci
<LLD
<LLD
<LLD
<LLD Ag-110m Ci (LLD
<LLD 1.19E-05 3.44E-05 i
)
Ba-140 Ci
<LLD
<LLD
<LLD
<LLD La-140 Ci
<LLD
<LLD
<LLD
<LLD 2.00E-04 2.08E-04 Unidentified Ci
<LLD
<LLD
<LLD
<LLD Total for Period Ci
<LLD
<LLD 1.09E-02 9.39E-03 (above)
)
Xe-133 Ci
<LLD
<LLD
<LLD
<LLD Xe-135 Ci
<LLD
<LLD
<LLD
<LLD
\\u Date: % 14- 'd Prepared by:
t I7!98 Approved by:
o Date:
CHEM /12QTR97' 10
' EFFLUENT AND WASTE DISPOSAL-SEMIANNUAL REPORT -
Supplemental Information Facility Guad Cities Nuclear' Power Station January - June 1997
. Licensee Commonwealth Edison Comoany 1.
Regulatory. Limits a.
For Noble Gases:
Dose rate 1.
Less than 500 mrem / year to the whole body.
2.
Less than 3000 mrem / year to the skin.
Dose Gamma Radiation
- 1. -Less than or equal to 5 mrad / quarter.
2.
Less than or equal to 10 mrad / year.
Beta Radiation 1.
Less than or equal to 10 mrad / quarter.
2.
Less than or equal to 20 mrad / year.
i b..c.
For Iodine-131 for Iodine-133, and for all radionuclides in particulate. form with half-lives greater than 8 days.
Dose Rate 1.
Less than 1500 mrem / year Dose
'1.
Less than or equal to 7.5 mrem / quarter 2.
Less than or equal to 15 mrem / year.
d.
For Liquid Less than or equal to 3 mrem to the whole body during any calendar quarter.
Less than or equal to 10 mrem to any organ during any calendar quarter.
Less than or equal to 6 mrem to the whole body during any calendar year.
Less than or equal to 20 mrem to any organ during any calendar
. year.
CHIN \\EAWRIT '
2.
Maximum Permissible Concentration a.,b.,c.,
For fission and activation gases, iodines, and particulates with halflives greater than 8 days, allowable release limits are calculated by solving equations 10.1 and 10.2 from the Offsite Dose Calculation Manual. The alarm setpoint is conservatively set at approximately 10% of the 10CFR20 limit.
d.
For liquid effluents allowable release limits are calculated by solving equations 10.3 and 10.4 from the Offsite Dose Calculation manual. The MPC values used for the monitors were as follows:
radwaste discharge 4.60E-05 uCi/ml service water 1.0E-05 uC1/ml 3.
Average Energy The average gamma energy used to calculate the alarm setpoints for the noble gas monitors was 0.655 Mev for the First quarter, and 0.518 Mev for the Second quarter.
4.
Measurements and Approximations of Total Radioactivity a.
Fission and Activation Gases:
b.
c.
Particulates:
The main chimney and reactor building ventilation exhaust systems are continually monitored for iodines and particulates.
These samples are pulled every 7 days and analyzed by gamma isotopic.
The particulate papers are composited every 31 days and sent to a vendor for Sr 89-90 and gross al]ha analysis. Noble gas grab samples are pulled and analyzed Jy gamma 1sotopic weekly.
Tritium samples are pulled and analyzed every month.
The continuous strip chart recorders for the monitors on the release points are reviewed monthly for spikes and the activity released is calculated.
An additional calculated activity for noble gases is added to the Main chimney release each month.
This calculation is done because most of the grab samples show less than the lower limit of detection due to the low amount of activity and the large dilution flow at the sample point.
The calculation takes into account the normal offgas train and the gland steam contribution to the release.
The avercge flow at the release points are used to calculate the curies released.
ClllMEAWRPT
d.
Liquid Effluents.
The river discharge tanks are analyzed before discharge by gamma isotopic. A composite representative portion of this sample saved. This is composited with other discharges that occurred every 31 days and is analyzed for tritium and gross alpha. The batch composites are composited quarterly and sent to a vendor for Sr 89-90 and Fe 55. The discharge bay is sampled every 31 days and analyzed by gamma isotopic, for tritium and gross alpha.
It is sampled quarterly and sent to a vendor for Sr 89-90 and Fe 55 analysis.
The tank volumes and activities are used to calculate the curies l
released for the River Discharge Tank. The total water released l
during the quarter and the activity is used to calculate the diluted activity released at the discharge bay, from batch discharges, e.
Estimated Total Error Percent The estimated total error percents were calculated by taking the square root of the sum of the squares of errors for sampling and measurement parameters.
The estimated total error percent for the solid waste radwaste curies is 12.3%.
f.
Less than the lower limit of detection (<LLD).
Samples are analyzed such that the Technical Specification LLD requirements are met. When a nuclide is not detected during the quarter then <LLD is reported.
1 5.
Batch Releases a.
Liquid 1.
number of releases 19 2.
total time 18.485 minutes 3.
maximum time 1.125 minutes 4.
average time 973 minutes 5.
minimum time 723 minutes 6.
average stream flow, discharge 49.9 gpm.
dilution 2.10E+05 gpm.
b.
Gaseous NONE CHIMTAWRIT
)
6.
Abnormal Releases a.
Gaseous NONE b.
Liquid 1.
On March 25, 1997 oil was identified in the Waste Water Treatment Plant (WWTP) effluent. The cause was 1000 gallons i
of slightly contaminated Turbine Lube oil (~4.2E-07 uC1/ml) made its way to the WWTP due to a leak from the oil storage l
tank to a floor drain which drained to the U-1/2 oil separator and finally to the WWTP.
It is estimated that no i
more than 5.0E-03 uCi were released during this evaluation.
This amount was added to the monthly effluent release l
calculations for March 1997.
i l
l CIID4\\E&WRPT
=
EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT Supplemental Information Facility Guad Cities Nuclear Power Station January - June 1997 Licensee Commonwealth Edison Comoany
'1.
Regulatory Limits a.
For Noble Gases:
Dose rate 1.
Less than 500 mrem / year to the whole body.
2.
Less than 3000 mrem / year to the skin.
Dose Gamma Radiation 1.
Less than or equal to 5 mrad / quarter.
2.
Less than or equal to 10 mrad / year.
Beta Radiation 1.
Less than or equal to 10 mrad / quarter.
2.
Less than or equal to 20 mrad / year.
b.. c.-
For lodine-131, for Iodine-133, and for all radionuclides in particulate form with half-lives greater than 8 days.
Dose Rate 1.
Less than 1500 mrem / year Dose 1.
Less than or equal to 7.5 mrem / quarter 2.
Less than or equal to.15 mrem / year.
d.
For Liquid Less than or equal to 3 mrem to the whole body during any calendar quarter.
Less than or equal to 10 mrem to any organ during any calendar quarter.
Less than or equal to 6 mrem to the whole body during any calendar year.
Less than or equal to 20 mrem to any organ during any calendar year.
CHEM \\EAWRPT J
2.
Maximta Permissible Concentration a.,b.,c.,
For' fission and activation gases, iodines, and particulates with halflives greater than 8 days. allowable release limits are calculated by solving equations 10.1 and 10.2 from the Offsite Dose Calculation Manual. The alarm setpoint is conservatively set at approximately 10% of the 10CFR20 limit.
d.
For liquid' effluents allowable release limits are calculated by solving equations.10.3 and 10.4 from the Offsite Dose Calculation manual. The MPC values used for the monitors were as follows:
radwaste discharge 4.60E-05 uCi/ml service water 1.0E-05 uCi/ml 3.
Average Energy The average gamma energy used to calcula'te the alarm setpoints for the noble gas monitors was 0.655 Mev for the First quarter, and 0.518 Mev for-the Second quarter.
4.
Measurements and Approximations of Total Radioactivity a.
Fission and Acti /ation Gases:
b.
c.
Particulates:
The main chimney and reactor building ventilation exhaust systems are continually monitored for iodines and particulates. These samples are pulled every 7 days and analyzed by gamma isotopic.
The particulate papers are composited every 31 days and sent to a vendor for Sr 89-90 and gross al)ha 6nalysis. Noble gas grab samples are pulled and analyzed )y gamma isotopic weekly.
Tritium samples are pulled and analyzed every month.
The continuous strip chart recorders for the monitors on the release points are reviewed monthly for spikes and the activity released is calculated. An additional calculated activity for noble gases is added to the Main chimney release each month.
This calculation is done because most of the grab samples show less than the lower limit of detection due to the low amount of activity and the large dilution flow at the sample point. The calculation takes into account the normal offgas train and the gland steam contribution to the release.
The average flow at the release points are used to calculate the-curies released.
~ CHEM \\EAWRPT I
u
d.
Liquid Effluents The river discharge tanks are analyzed before discharge by gamma isotopic. A composite representative portion of this sample saved. This is composited with other discharges that occurred every 31 days and is analyzed for tritium and gross alpha. The batch composites are composited quarterly and sent to a vendor for Sr 89-90 and Fe 55. The discharge bay is sampled every 31 days and analyzed by gamma isotopic, for tritium and gross alpha.
It-is sampled quarterly and sent to a vendor for Sr 89-90 and Fe 55 analysis.
The tank volumes ano activities are used to calculate the curies released for the River Discharge Tank. The total water released during the quarter and the activity is used to calculate the diluted activity released at the discharge bay, from batch discharges.
e.
Estimated Total Error Percent The estimated total error percents were calculated by taking the square root of the sum of the squares of errors for sampling and measurement parameters. The estimated total error percent for the solid waste radwaste curies is 12.3%.
f.
Less than the lower limit of detection (<LLD).
Samples are analyzed such that the Technical Specification LLD requirements are met. When a nuclide is not detected during the quarter then <LLD is reported.
5.
Batch Releases a.
Liquid 1.
number of releases 19 2.
total time 18.485 minutes 3.
maximum time 1.125 minutes 4.
average time 973 minutes 5.
minimum time 723 minutes 6.
average stream flow. discharge 49.9 gpm.
dilution 2.10E+05 gpm.
b.
Gaseous NONE CHEM \\EAWRIT -
6.
Abnormal Releases a.
Gaseous NONE b.
Liquid 1.
On March 25. 1997 oil was identified in the Waste Water Treatment Plant (WWTP) effluent. The cause was 1000 gallons of slightly contaminated Turbine Lube oil (-4.2E-07 uCi/ml) made its way to the WWTP due to a leak from the oil storage tank to a floor drain which drained to the U-1/2 oil separator and finally to the WWTP.
It is estimated that no more than 5.0E-03 uC1 were released during this evaluation.
This amount was added to the monthly effluent release calculations for March 1997.
CllIME&%1 TIT
CaEd WE CITIES STAT 13 Jmrt rd1997
)
h 33 ft. VIE SPiB ard E2 DIREnl3 196-33 ft.DiffEEXIIAL TEME INER OF 0ESRIAll0NS = 1988 VAMS ARE PEEEXT OCCREEE V12 DIRECil3 CLASSES =
STABilliY CLASSES -----
SPIB ---
CLASS I NE E EE E ESE SE SSE $ $2 2 kSW W N W N TOTAL H E 2 I 55 E [5 TOTAL G.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 C 2.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 A B.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 L $$.00.00.00.00.00.00.00.00.00.00.00.00.00.00.50.00.00
.00 N E.00.00.00.00.00.E.00.00.00.00.00.00.00.00.00.00.00
.00 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.00 0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 1 2.00.00.00.00.05.00.00.05.00.00.05.05.00.00.00.00.20
.20 I.45.15.30.05.10.10.15.25.15.15.50.25.5.35.20.35 3.U 3.77 3 55.35. 5.35.35.20. 5.25.10. 5. 5.15.35.30.70. 6.20 4.78 4.78 E.10.15.20.15.6.20.50.15.05.30.10.30.30.10.20.10 3.37 3.37
)
ES.00.00.05.15.40.50.30.20.05.00.10.00.00.05.00.05 1.5 1.N I
13.98
)
a.i0.00.a.05.20.05.m.30.i0.20.6.6.60.50.5.s 3.n 3.n E.00.00.05.10.05.05.00.05.05.05.00.05.15.10.05.20.96
.96 4 2.05.10.00.10.M.20.15.15.05.15.10.40.5.6.05.05 2.46 2.46
- I.50.75.80.86 1.31.75 1.11.86.65.05.70 1.36 3.82 5.33 3.07.96 22.89 22.89 7 55.20.05.05.65 1.01.96 1.06.60.50.60.96 1.71 1.01 1.41.65.30 11.72 11.72 5.00.00.05.20.00.55.25.25.35.35.05.00.00.05.00. 5 2.16 2.16 ES.00.00.00.00.15.5.05.00.00.10.00.00.00.00.00.00.55
.55 44.47 0.25.10. 5. 5. 5.25.00.10.30. 5.50.30 1.91 1.!!.75. 5 6.54 6.54 E.00.00.00.05.10.00.00.00.00.00.05.05.20.10.00.00.55
.55 8 2.05.00. 5.05
.0"
. 5.00.00.00.05.00.10.50.35.40. 5 1.86 1.86
- t.30.35.75.96 2.01 1.!!.35.05.10.20.20.86 4.58 7.55 2.06.10 !!.0
!!.0 1 SS. 5.10.00.15.10.60.20. 5. 6.70.50.35.30.35.05.15 4.12 4.12 2 5.00.00.00.00.00.05.00.00.15.00.00.00.00.00.00.00.20
.20 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 34.91 G.00.00.00.00.00.20.00.00.00.00.05.00.10.30.00.00. 6.65 1 E.00.00.00.00.00.05.00.00.00.00.00.05.00.05.00.00.15
.15 3 2.00.00.00.00.00.00.00.00.00.00.10.00.35.30.00.00.75
.75 I.00. 5.15. 5.05.50.00.00.00.00.00.15 1.61 1.66.45.05 4.93 4.93 j
l $5.00.00.00.00.00.00.00.00.00.00.00.00.00.00.05.05.10
.10 1
8 5.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
{
Es.00.00.00.m.00.a.00.m.s.00.m.m.m.00.00.00.00
.00 6.59 l
t
Cdd 50 CITIES STAtl01 JauryArch 1997 33 ft. WIE SPEED nd V!E DIRECil8 196 33 ft. DIMENTIAL TDPERATM i
-- -- --- SIMILM CUSE!
gg.........
W!E DIECilt CUSE5 ----
CLASS I E E [E I IE E SE 5 53 9N V N W N TOTAL U E 2 I
$5 E El TOM
]
f tu.00.s.00.s.00.00.00.a.00.s.00.00.00.00.00.00.00.00 I
1 m.R.00.#.s.00.n.00.00.00.00.00.a.n.00.m.00.00
.00 l
9 SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 N.00.00.00.00.00.5.00.00.00.00.00.00.00.00.00.00
.5
.05 2 55.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 4 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.N
.00 IS.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.05 B.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 6 W.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 i 2.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 I.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 2 55.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 4 M5.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.00 101 2.41 2.06 3.17 4.18 6.24 7.04 4.38 3.17 3.22 3.42 4. 2 6.79 16. 5 21.13 8.80 3.17 100.00 10.92 1.66 5.28 53.27 20.72 5.73 2.41 1 2.00 Wid Directim by Stellity i N E EE I EE SE SSE 5 52 WH W W W N TOM -5fMilm CLA55[5-
.35.10.35.10. 5.50.00.40.40.45 1.01.75 2.62 2.01 1.11.50 10.92 htruly thstdle
.00.00.05.15.15.10.00.05.05.05.05.15.35.25.05.20 1.66 Mderately kstile
.10.10.05.15.05.45.15.20.05.20. 5.55 1.11 1.31.45.10 5.28 Slittly hstele 1.26 1.!! 2.01 2.!! 3.47 2.62 1.61 1.16.91.40 1.41 2.62 10.26 14.89 5.78 1.46 53.27 betral
. 2.40.40 1.16 1.31 1.81 1.51.75 1.21 1.56 1.61 2.41 1.61 2.46 1.!!.70 20.72 Sil$tly Stele
.10.15. 5.35.45.80.75.40.55.65.15.30.30.15.20.15 5.73 MWerately Stele
.00.00.05.15.55.75.35.20. 5.10.10.00.00.05.00.05 2.41 htrmly Stdle Vid Directim by Wid Sped I N E EE E (E SE 55[ 5 SW WH V N W N TOR -VIE SPES CLASES-
.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 CALM
.91. 5.91.70 1.!! 1.06 1.21.75. 2.70.91.96. 5 1.!!. 5.70 13.98 0.9 - 3.5 $
.M.91 1.061.96 2.72 2.82 2.62 2.!! 1.71 1.512.26 3.97 5.N 8.5 4.181.8144.47 3.6 7.5 $
.65.55 1.06 1.26 2.26 2.36.55.20 1.01 1.21 1.26 1.66 7.49 9.56 3.27.55 34.91 7.6 12.5 $
.00. 5.15. 5.05.75.00.00.00.00.15.20 2.06 2.31. 2.10 6. 9
!!.6 18.5 $
.a.N.n.00.s.05.00.00.00.00.00.a.00.00.00.00.05 18.6 24.5 $
.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
> 24.5 $
3 Cdd SE Cll!ES STAT 13 Jury 4rd 1997 296 ft. Wie SPE9 al Wit DIRECT 13 296-33 ft. DIRERSTIAL IDPERATRE RHER Of 35ERVATIO 2101 VALES RE PERCRT OCCMEEE Sp((p......................... yte DIRECil0N CLASSE5 - ---- --- ----- -------
ST81LITY uASSE5 - ------
CIA 55 i K E EE E ESE SE SSE 5 52 2N I N E N TOTAL GE 2 I
!! MS ES TOTAL G.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 C 2.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 A I.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 l 55.00.00.06.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 N E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.00 0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 W.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 1 2.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 I.14.00.19.05. 5.00.00.05.00.00.14.00.14.05.10.05.95
.95 3 55. 5. 5.00.05. 5.05.00.00.10. 5.00.19.00.00.05.00.62
.62 5.00.05.00.10.00.05. 5. 5.05.05.05.05. 5.00.00. 5.57
.57 IS.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 2.14 0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 E.5.00.00.05.00.05.00.05.05.05.05.00.10.10.05.00.57
.57 4 2.00.00.10.14.10.05.05.05. 5.00.14.05.14. 5.10.10 1.09 1.09 t.48.4.62.19.43.10.57.14.43.29.48.57.10.29.4.33 5.95 5.95 7 55.19. 5.14.10.19.14.14.10. 5.19.19.14.19.24.19.00 2.24 2.24 E.00.00.00.00.10.19.19.10.33.05.10.00.10.00.05.10 1.29 1.29 ES.00.00.00.00.00.00.5.00.00.5.00.5.00.00.00.00.14
.14 11.28 G.00.00.5.00.00.00.00.00.00.10.10.14.14.5.10.10.76.76 E.14.05.14.5.5.19.00.00.00.05.05.10.33.19.19.10 1.52 1.62 8 2. 5.00.14.00.10.19.00.19. 5.00. 5.14. 4.19.19.29 2.05
!.5 I. 4.43.71.38 1.29. 4.52.52.76.19.52 1. 5 1.52 3.05 3.19.95 16.04 16.04 1 55.24.19.29.14. #. 5.29.29.24. 4.29.43.24. 4.76.57 5.43 5.43 1 MS.05.05.05.05.33.10.38.24.19.10.14.00.05.14.10.00 1.95 1.95 IS.00.00.00.00.10.00.05.10.10. 5. 5.00.10.10.00.00.62
.62 28.%
B.00.5.00.00.05.10.00.14.00.14.00.00.5.24.19.00.95.95 1 E.00.10.5.00.00.05.00.10.00.00.19.05.38.38.14.05 1.4 1.48 3 2.00. 5.00.00.10.19.00.00.19.00.10.24.52.52.33. 5 2.28 2.28 B.29.19.48.571.191.051.19.6.43.24.33.71 1.90 7.47 2.67.6219.80 19.80 155.14.5.00.24 1.5.67.81.76.29.M 1.5.76.5.4.24.24 8.47 8.47 8 E.00.00.00.14.10.10.24.29.05.29.10.05.10.00.00.00 1.43 1.43 ES.00.00.00.00.00.00.5.14.10.10.00.00.5.00.00.00.43
.43 34.N
Cadd WE CITIES stall 5 Jimary&cn 1957 296 ft.W!E SPEED ad VIE DIRECil5 296 33 ft. DIffESTIAL TDl9tAIRE SPEED -- - - - - - - --- - - - WIS DIEW3 UES --- --
--- ----- ST81LITT MES -- - - --
CLAS5 I E E EE E ESE SE SSE 5 SW WN 1 N W N TEAL EU E 50 1 55 E ES TOTAL EU.00.00.00.00.00.00.5.00.10.10.5.00.00.5.5.00
.2.2 1 E.00.00.00.00.00.10.05.00.00.00.10.05.00.14.10.00.52
.52 9 2.00.00.00.00.00. 5.00.00.00.95.00.00.19.14.00.00.43
.0 N.00.10.0.62.0.67.14.05.19.N.29.0 1.71 3.71 2.05.14 11.23 11.23 2 SS.14.00.00.00.05. 4.62.29.76.33.57.33.24.19.00. 5 4.05 4.05 4 E.00.00.00.00.00.10.14. 00.10.29.14.00.00.00.00.00.76
.76 IS.00.00.00.00.00.00.00.00.00.05.00.00.00.00.00.00
.5
.05 17.42 EU.00.00.00.00.00.00.00.00.5.00.00.00.00.00.00.00.05. 5 6 E.00.00.00.00.00.00.00.05.10.00.10.00.00.00.00.00.24
.H T Sli.00.00.00.00.00.10.00.00.00.00.5 A.00.00.00.00.14
.14 I.05.00.00.05.00.19.00.00.05.00.00.00 1.57 1. 5. 4.00 4.24 4.24 2 55.00.00.00.00.00.00.00.00.33.62.19.00.00.00.00.05 1.19 1.19 4 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 5.5 101 2. 4 1.86 3.38 2.90 6.19 5.43 5.57 4.14 5.09 5.00 5.57 5.52 11.11 20.09 11.76 3.81 100.00 2.14 4. 0 6.00 58.21 21.99 6.00 1.24 100.00 Wid Directin by Stdility i N E EE E ESE SE SSE 5 SW WG V N N N TOTAL -5TEILITY CLASSES-
.00.05.05.00.05.10.05.14.14.33.14.14.19.33.33.10 2.14 Extratly hstele
.19.14.19.10.05.38.05.19.14.10.48.19.81.81.48.14 4. 0 MWerately Unstdle
. 5.05.24.14.29.57.05.24.29.05.33. 0 1.33.90.62. 0 6.00 Slightly hstdie 1.0 1.19 2.0 1.86 3.2 2.48 2.0 1.24 1.86 1.00 1.76 2.76 6.9516.42 8.95 2.09 58.21 hatral
.76.33. 0.52 1.81 1.38 1.86 1. 0 1.76 2.52 2.28 1.86 1.52 1.38 1.24.90 21.99 Slightly Stele
. 5.10.05.29.52.32 1.00.67.71.76.52.10.29.14.14.14 6.00 Nderately Stdle
.00 00.00.00.10.00.14.24.19.24.05. 5.14.10.00.00 1.24 Ertruely Stele Wid Directin bylid Speed X N E EE E ESE SE SSE 5 SW WG V N N N TOTAL WIE SPEED CLASSES-
.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 CALM
.19.10.19.19.10.10.05.10.14.10.19.24.19.5.H.10 2.14 0.9 3.5 sph
.71.52. 5.48.81.52 1.00.43.90.62. 5.81.62. 6. 5.52 11.28 3.6 7.5iph
.95.71 1.38.62 2.331.001.241.331.33.951.191.5 2.5 4.19 4.52 2.00 28A 7.6 12.5 sph
. 0. 0.52.95 2. 4 !.14 2.28 1.90 1. 5 1.62 1.76 1.81 3.86 9.09 3.57.95 34.84 12.6 - 18.5 mph
.14.10. 0.62.48 1. 2 1.00.33 1.14 1. 8 1.14.81 2.14 4.24 2.19.19 17.42 18.6 24.5 sph
.5.00.00.05.00.29.00.5.52.62.33.00 1.57 1.E.4.5 5.5
> 24.5 sph I
Cdd 92(1115 STA1101 AprlWe 1997 33 ft.115 SPES W VIE DIECTION 196-33 ft. D!ffEBilAL TERRATE NIBOf 0853 VAT 1015 2164 RES E SUIKCREKE
- --- - ST21LITY CLASSE5 SPB
- - -- --- - -- --- --- WT OlECTM CLASE5 --.- --.
CLAS5 I E E EE E EE E SE 5 52 2B I N N N TOTAL G E 2 i SS E B TOTAL R.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 W.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 00 C 2.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 A I R.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 L $$.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 1 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 B.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.00 5.00.00.00.00.00.00.00.00.00.00.00.00.00. #.00.00.00.00 t.00.00.00.00.00.00.00.00.00.00.00.00.00.00.5.00.05
.05 1 2.00.00.00.00.00.00.00.00. 5. 5.00.00.00.05. 5.00.18
.18
- I.5.00.00.23.28.42.28.23.14.14.47.N.23.33.19.05 3.47 3.47 3 55.4.32.60.32.M.60.9.E.2.E.4.55.37.69.5.32 8.09 8.09 E.29.53 1.01.0.58 1.6 1.01.67.67.43.39.39.39 1.01.39.19 10.07 10.07 5.00.20.35.50.2 1.59.75.E.10.5.5.30.5.40.05.00 6.52 6.52 28.37 0.42.28.18.32.28.00.M.32.37.42.92.9.55 1.02.2.32 6.18 6.98 E.5.18.18.05.00.14.05.5.05.5.32.14.14.28.00.18 1.5 1.5 4 2.M.18.14.23.14.14.05.28.23.23.92.14.23.4.23.09 3.79 3.79 I.60.6 1.06 1.5 1.48 1.20.60.74.46.51 1.5 J4.6.E.E.51 13.03 13.03 7 55.E.23 1.39 1.57 1.16 1.02.79.28.23 1.20 1.5.79 1.11 1.20.55.51 13.91 13.91 E.05.05.32.09.5.42.14.18.6.5.5.00.00.14.18.M 1.N 1.94 0.00.00.00.00.00. 2.09.00.00.00.00.00.00.00.00.00.69
.H 42.24 0.14.37.32.42.32.28.32.28. 5.42.83.18.37.92.97 1.02 7.26 7.26 5.00.09.05.14.14. 5.05.00.00. 5.14.00.00. 5.14.05.97
.97 8 2. 5.18.18.14. 5. 5.00.05.00.05.14. 5.14. 5. 5.09 1.39 1.39 I.E.14.92 1.5.74.37.6.18.5.32.55.23.23 1.48 1.29.51 10.30 10.30 155.N.00.09.55.32.M.23.5.M.4 1.5.09.09.5.14.05 3.56 3.56 2 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 B.R.00.00.00.00.00.00.00.00.00.00.00.#.00.00.00.00
.00 23.48 G.00.5.23.18.09.00.00.00.00.00.00.05.M.4.51.5 1.11 1.71 1 5.00.00.00.00. 5.00.00.00.00.00.00. 5.00.14. 5.00.28
.28 3 2.00.00.00.5.5.5.00.00.00.00.00.5.R.18.09.00.51
.51 I. 5.00.14.32.00. 5.14.00.00.00. 5.09.32 1.06.32.05 2. 0 2.0 1 SS.H.00.00.00.00.5.00.05.5.00.05.00.00.00.09.00.28
.28 8 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 5.H.00.00.00.00.N ~.00.00.00.00.00.00.00.00.00.00.00
.00 5.41
CaEd 50 CITIES STATIS April 4ne 1997 33 ft. VIE SPEED ad W!E DIECil5 196-33 ft. DIFFEEEIR IDPRATRE Sp[g.................................. VIE DIECil5 M25 - ---- ------
--- -- STEILI1Y MES -
CLA55 i M E IE E EE E SE $ 52 2N V N W M TOTAL R E 50 1 55 E El TOTE D.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 1 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 9 2.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 I.00.00.00.00.00.00.00.00.00.00. 5.23.18.00.00.00
.4
.4
! 55.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 4 5.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 ES.00.00 '.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 B.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 6 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 i 2.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 I.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.N 2 55.00.00.00.00.00.00.00.00.00.00.00.00. 5.00.00.00
.5
.5 4 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.05 TOT 3.57 3.4 7.18 8.89 7.N 8.68 5.87 4.70 3.32 5.319.33 5.03 5.6410.617.00 4.08100.0015.H 3.19 5.87 29.90 5.2 !!.017.21 100.00 Wid Directie by 5tability i E E IE E ESE SE SSE $ 52 2 WW W N N N TOTAL -5TABilllY CLASSES-
.55.H.74.92.69.28.42.60.4.D 1.76.8 1.02 2.40 2.36 1.39 15.N Extratly kstable
.05.28.23.18.18.23.09.09.05.09. 4.18.14. 4.23. 4 3.19 MWerately thstable
.14.37.32.42.28.23.05.32.28.32 1.06.23. 4.74. 4.18 5.87 511ptly kstable 1.39.79 2.13 3.70 2.50 2. 5 1,71 1.16.70.97 2.36 1.67 1.67 3.52 2.45 1.11 29.90 leutral 1.11.55 2.2 2.6 2.261.761.621.02.97 2.313.001.431.621.N.5.2 5.5 Slittly 5 table
.H.58 1.H.72.62 1.91 1.15.86.77.53.43.39.19 1.15.57.29 !!.01 MWerately Stale
.00.20.35.50.80 2.19.N.6.10.25.25.30.35.40.05.00 7.!! Extratly Stable Wid Direction by Wid Sped i K E EE I EE SE 55E $ SW 2N W W W W TOTAL -VIE SPED CLASSES-
.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 CALM
.N 1.5 1.96 1.68 2.44 4.11 2.64 2.20 1.56 1.52 1.56 1.61 1.M 2.48.81.56 28.17 0.9 3.5 sph 1.51.573.53.513.103.511.801.51.432.504.712.402.733.742.501.7142.24 3.6 7.5 sph
. 0.79 1.57 3.14 1.62.92 1.29.55.28 1.29 2.91.55. 0 2.54 2. 0 1.71 23.48 7.6 - !!.5 gh
. 5. 5.37.55.18.14.14.05.05.00. 5.23.51 1. 5 1.06.09 5.41
!!.6 18.5 sph
.00.00.00 '.00.00.00.00.00.00.00.05.23.18.00.00.00
.4 18.6 24.5 sph
.00.00.00.00.00.00.00.00.00.00.00.00.05.00.00.00
.5
> 24.5 sph
CmEd QU4D UTIES STAlla Apri14me 1997 296 ft. VIE SPEED af VIE DIRECil3 296-33 ft. DIff[BTIAL TEFERAME INER Of 0859VAll35 2145 VALUES ARE PERCSIOCCWREEE STEILITY CLASSE5 -
Spg
......... V!E DREOD CLESE5 -------
CLASS X N E EE E ESE SE SSE 5 SSV 2N V N E N TOTAL G E SU R 55 E IS TOTAL G.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 C SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 A I.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 L $$.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
,00 I NS.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.00 5.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 1 2.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 I.09. 5.00.00. 5. 6.14. 5.14.14. 5.09.09.09. 5.09 1.31 1.31 3 55.18.00.00.06.00.12.00.00.00.00.00.06.00.00.00.00.42
.42 E.6.14.05.00.H.05.00.05.05.00.00.09.00.00.00.5
.5
.6 B.00.00.00.00.06.00.00.00.00.06.00.00.00.00.00.06.19
.19 2.56 0.00.14.00.05.00.00.00.00.00.00.00.05.05.05. 5.00.37.37 E.14.09.6.05.05.09.00.00.00.3.14.14.23.5.09.09 1.40 1.40 4 SU.09.19.23.00.5.14.00.5.09.28.33.09.19.37.00.23 2.33 2.33
- I.33.42.23.51.23.33.42.42.42.51.75.37.42.28.09.09 5.83 5.0 7 55.19.37.33.14.E.14.14.23.28.42.23.19.19.14.23.09 3.96 3.96 E.6.19.00.09.23.05.14.33.09.09.00.14.09.05.09.14 1.82 1.82 ES.00.00.00.00.90.05.H.M.5.5.05.05.09.E.00.00
.56 16.27 0.09.28.23.14.09.09.14.19.19.19.14.5.14.28.19.28 f.70 2.70 E.19.14.14.14.14.19.6.14.09.14.23.09.09.28.19.28 2.56 2.56 8 $U.14.19.14.14.19.05.00.28.5.14.37.09.09.23.05.23 2.38 2.38 X.33.51.84.56 1.31.65.19.37.37.5.70.23.23.70.37.28 8.30 8.30 1 55.33.37.70.98.98.33.75.70. 6.56.47.42.56.70.33.33 9.14 9.14 2 E.28.09.6.09.37.33.33.93.42.47.05.23.19.14.37.23 4.62 4.62 ES.00.00.00.00.00.09.14.37.19.19.00.05.M.09.14.00 1.35 1.35 31.05 B.00.14.14.5.14.5.05.00.19.33.23.M.09.37.33.09 2.33 2.33 1 E.00.00.09.5.19.05.09.14.09.09.14.00.05.09.09.05 1.!!
1.21 3 $U.00.00.14.M.05.5.09.5.09.14.19.05.00.05.23.05 1.26 1.26
- I.51.42.98 1.E.N.47.51.37.28.37.47.79.23.93.84.70 10.35 10.35 155.05.19.E 1.17 1.07.93.47.42.33 1.03.75.H.47.98.28.33 9.6 9.5 8 5.H.19.23.14.14.19.5 1.17.6.56.9.00.5.09.14.14 4.52 4.52 ES.00.00.00.00.00.5.14.5.37.05.05.00.00.00.00.00.79
.79 30.12
CmEd 50 CITIES STAT 13 Aprl14e 1997 296 ft.WIE SPEG ad VIE DIECTIR 296 33 ft. DIffEENTIALIDPERATRE STRllm CLEES ----------
sp[g......
.............. VIE DIECT!5 CLEE5 ---
CLASS I E E EE E ESE SE SSE 5 SW 2N V N W W TOTAL EU E 2 1 55 E ES TOTAL EU.2.5.14.00.00.00.00.19.M.09.5.00.5.61.51.5 1.91 1.91 1 2.00.05.00.33.05.00.00.00.00.19.19.00.05.33.28.05 1.49 1.6 9 2.00. 5.00.19.14.00.05.00.00.09.00.00.05.19.14.05.93
.93 N.5.00.42 1.26.N.09.56.28.H.47.70.09.19 1.03.79.23 6.67 6.67 2 $$.00.00.19.61.14.5.5.05.23 1.03.42.M.23.00.5.00 3.26 3.26 4 E.00.00.00.00.00.00.00.05.19.09.00.00.00.00.00.00.33
.33 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 14.59 EU.00.00.5.00.00.00.00.00.00.00.00.00.05.05.14.00.28.28 6 E.00.00.5.05.00.00.00.00.00.00.00.00.00.05.5.00.19
.19 1 2.00.00.00.00.00.00.00.00.00.09.00.00.09.33. 5.00.56
.H I.00.00.00.5.05.14.09.09.09.P.28.28.75 1.40.P.05 4.01 4.01 2 55.00.00.00.05.00.05.00. 5. 5.19.00.00.00.00.00.00
.N
.37 4 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 E3.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 5.41 TDT 3.30 4.29 6.15 8.9 7.66 5.015.36 7.18 5.83 9.15 7.5 4.40 5.0810.02 6.57 4.2100.00 7.60 6.5 7.46 35.46 26.8111.93 2.M 100.00 Wid Directie by 5tability i K E EE E ESE SE SSE 5 SW 9N V N N N TOTAL -SIABilllY CLASSES-
.09.E.H.23.23.19.19.37.47.61.42.19.37 1.35 1.21.47 7.60 Extruely kstable
.33.28.37.61.42.33.19.28.19.51.70.23.42.M.70.47 6.5 Moderately kstable
.!!.42.51.42.42.23.14.37.23.75.5.23.42 1.17.47.H 7.46 Slipily kstable 1.351.40 2.47 4.012.N 1.771.91 1.01.40 2.52 2.981.861.914.43 2.521.6 36.46 hatral
.74.931.86 3.00 2.N 1.E 1.451.451.54 3.221.861.321.451.82.93.75 26.81 Sliptly Stable
.56.61.37.33.N.61 1.12 2.52 1.40 1.!!.14.47.33.28.61.56 11.93 Moderately Stable
.00.00.00.00.06.23.37.H.61.34.M.M.19.14.14.06 2.5 Extratly Stable Wid Directie by Wid Speed
-1 E E EE E ESE SE ME 5 52 WH V N N N TOTAL -VIE SPEED CLASSES-
.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 CALM
.N.19.05.06.20.26.14.14.19.20.09.5.M.5.5.20 2.56 0.9 3.5 W
.N 1.40.5.N 1.!!.79.791.12.931.61.491.031.261.03.56.E 16.27 3.6 - 7.5 $
1.351.592.142.53.08!.721.02.981.962.331.961.171.402.421.01.031.5 1.6 !!.5 $
.6.93 2.24 3.12 2.421.86 2.00 2.24 2.00 2.H 1.91 1.6.5 2.5! 1.91 1.35 30.12 12.6 18.5 $
.09.19.75 2. 2.70 -.19.70.56.61 1.96 1.35.19.56 2.14 1.82.42 14.59 18.6 - 24.5 W
.00.00.09.14.5.19.09.14 14.E.28.28.5 1.82.61.5 5.41
> 24.5 #
QCCP 0100-16 UNIT 1(2)
REVISION 4 ATTACHMENT A (Page 1 of 5)
EFFLUENT & WASTE DISPOSABLE SEMI-ANNUAL REPORT GASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES Period: July through December 1997 Est. Total A. FISSION & ACTIVATION GASES UNIT QUARTER QUARTER Error %
- 1. Total Release Cl 1.43E+01 3.34E00 12.4
- 2. Average release rate for the period gCl/see 1.80E00 4.20E-01
- 3.
- Percent of ODCM timit Chimney &
5.38E-03 1.46E-03 Stack 2.67E-04 6.35E-05
- 8. 10 DINE
- 1. Total fodine-131 Cl 1.08E-03
<LLD 40.0
- 2. Average release rate for the period nCl/sec 1.36E 04
<LLO C. PARTICULATES
- 1. Particulates with half-lives >8 days Cl 5.79E-03 8.38E 03 30.1
- 2. Average release rate for the period gCi/sec 7.28E-04 1.05E-03
- 3. Gross alpha radioactivity Ci
<LLD
<LLD D, TRITIUM
- 1. Total Release C1 2.59E+01 7.13E00 8.0
- 2. Average release rate for the period sci /sec 3.26E00 8.97E-01 E. lodine 131 & 133, Tritium & Particulate
- 1. Percent of ODCM timit Chimney & Stack 4.65E-01 2.29E-01
- NOBLE GAS GAMMA / NOBLE GAS BETA DOSE LIMITS Document Retention:
Life of Plant 14
]
QCCP 0100-16 UNIT 1(2)
REVISION 4 ATTACHMENT A (Page 2 of 5)
EFFLUENT & WASTE DISPOSABLE SEMI-ANNUAL REPORT MAIN CHIMNEY GASEOUS EFFLUENTS CONTINUOUS MODE BATCH MODE i
FOURTH THIRD FOURTH NUCLIDES RELEASED THIRD l
- 1. Fission gases UNIT QUARTER QUARTER QUARTER QUARTER Kr 85 Ci
- 3. 74E- 01
<tLD NA NA Kr-85m Cl 4.06E 01 2.16E-01 NA NA Kr-87 Cl 7.2SE-01 6.85E-02 NA NA Kr-88 Ci 6.10E-01 1.90E-01 NA NA Xe-133 Cl 9.31E-01 4.55E 01 NA NA xe-135 Ci 9.22E-01 9.05E-02 NA NA l
xe-135m C1 2.46E00 3.39E-01 NA NA xe-138 C1 7.51E00 1.42E00 NA NA Ar-41 4.06E-01 5.65E-01 NA NA Total for Period C1 1.43E+01 3.34E00 NA NA M
NUCLIDES RELEASED THIRD FOURTH THIRD FOURTH
- 2. lodines UNIT QUARTER QUARTER QUARTER QUARTER I.131 Cf 1.03E-03
<LLD NA NA l-133 Ci 4.66E-03
<LLD NA NA l-135 Ci 4.68E-03
<LLD NA NA Cl 1.04E-02
<LLD NA NUCLIDES RELEASED THIRD FOURTH THIRD FOURTH
- 3. Particulates UNIT QUARTER QUARTER QUARTER QUARTER Sr-89 Ci 5.26E-05 1.11E-04 NA NA j
Sr-90 Ci
<LLD
<tLD NA NA Cs-134 Ci
<tLD
<LLD NA NA Cs-137 Ci
<tLD
<LLD NA NA Ba-140 Cl 7.93E-05 (LLD NA NA La 140 Ci
<LLD
<LLD NA NA Cr-51 Ci
<LLD
<LLD NA NA Mn-54 Ci
<LLD
<LLD NA NA Co-58 Ci
<LLD
<LLD NA NA Co 60 C1 2.21E-04 1.07E 04 NA NA Mo-99 CI
<LLD
<LLD NA NA Ag-110m Ci
<tLD
<LLD NA NA l 131 Ci 2.79E-05
<LLD NA NA j
1-133 C1 2.61E-04
<LLD NA NA fotal for Period Cl 6.42E-04 2.18E-04 NA NA
- Projected data based on previous six months available data.
15
gccP 0100-16 UNIT 1 (2)
REVISION 4 ATTACHMENT A (Page 3 of 5)
EFFLUENT & WASTE DISPOSABLE SEMI-ANNUAL REPORT REACTOR VENTILATION GASEQUS EFFLUENTS CONTINUOUS MODE BATCH MODE NUCLIDES RELEASED
<LLD NA NA Kr-85m Cl
<LLD
<LLD NA NA Kr-87 Ci
<LLD
<LLD NA NA Kr-88 Ci
<LLD
<LLD NA NA xe-133 Ci
<LLD
<LLD NA NA xe-135 Ci
<LLD
<LLD NA NA xe-135m Ci
<LLD
<LLD NA NA AR-41
<LLD
<LLD NA NA Total f or Period Cl
<tLD
<LLD NA NA M
NUCLIDES RELEASED
- 2. Iodines UNIT QUARTER QUARTER QUARTER QUARTER l-131 Ci 2.29E-05
<LLD NA NA 1-133 Cl 1.52E 04
<LLD NA NA I-135 Ci
<LLD
<LLD NA NA Total for period Cl 1.75E-04
<tLD NA NA NUCLIDES RELEASE 0
- 3. Particulates UNIT QUARTER QUARTER QUARTER QUARTER Sr-89 Cf 5.24E-06 3.27E 05 NA NA Sr-90 Ci
<LLD
<lLD NA NA Cs-134 Ci
<LLD
<LLD NA NA Cs-137 Ci
<LLD
<LLD NA NA Ba-140 Ci
<LLD
<LLD NA NA La-140 Ci
<LLD (LLD NA NA Cr-51 Cl 1.61E-03 1.56E-03 NA NA Mn-54 Ci 8.27E-04 2.80E-04 NA NA Co-58 Cl 1.47E-04 8.94E-05 NA NA Co-60 Cl 1.66E-03 5.96E 03 NA NA Mo-99 Cl 9.01E-04 2.36E-04 NA NA Ag 110m Ci
<LLD
<lLD NA NA 1-131 Ci
<LtD
<LLD NA NA 1-133 Ci (Lt D (LLD NA NA Total for Period i Cl 5.15E-03 8.16E-03 NA NA 16
QCCP 0100-16 UNIT 1 (2)
REVISION 4 ATTACHMENT A (Page 4 of 5)
EFFLUENT & WASTE DISPOSABLE SEMI-ANNUAL REPORT LIQUID EFFLUENTS - SUMMATION OF ALL RELEASES
~
THIRD FOURTH Est. Total A.
FISSION & ACTIVATION GASES UNIT QUARTER QUARTER Error %
- 1. Total Release (not including tritium, Ci 2.98E-03 6.00E-03 5.6 gases & alpha)
- 2. Average diluted concentration during pCi/mL 1.97E-10 6.96E-10 batch discharges for the period 3.
Percent of applicable limit
- 2.00E-03 2.28E-03 8.42E-04 9.64E-04
- 4. Maximum diluted concentration during pCi/mL E.23E-10 1.15E-09 batch discharges B. TRITIUM l
- 1. Total Release Ci 7.97E00 6.05E00 4.0
- 2. Average diluted concentration during pC1/mL 5.28E-07 7.02E-07 batch discharges for the period 3.
Percent of applicable limit 1.76E-02 2.34E-02 C.
DISSOLVED 4 ENTRAINED GASES l
- 1. Total Release Ci
<LLD 1.96E-05 5.6
- 2. Average diluted concentration during pCi/mL
<LLD 2.27E-12 batch discharges for the period 3.
Percent of applicable limit NA 1.14E-06 D.
GROSS ALPHA ACTIVITY
- 1. Total Release Ci
<LLD
<LLD NA
- 2. Average diluted concentration during pCi/mL
<LLD
<LLD batch discharges for the period E. VOLUME OF WASTE RELEASED (prior to Liters 1.60E+06 1.40E+06 dilution)
F. VOLUME OF DILUTION WATER USED Liters 1.51E+10 8.62E+09 DURING BATCH DISCHARGES G.
TOTAL VOLUME OF DILUTION Liters 4.85E+11 3.63E+11 WATER USED DURING PERIOD (quarter)
Whole Body / Organ (ODCM) 0 17
OccP 0100-16 UNIT 1 (2 )
REVISION 4 ATTACHMENT A (Page 5 of 5)
EFFLUENT & WASTE DISPOSABLE SEMI-ANNUAL REPORT LIQUID EFFLUENTS CONTINUOUS MODE BATCH MODE THIRD FOURTH THIRD FOURTH NUCLIDES RELEASED UNIT QUARTER QUARTER QUARTER QUARTER Sr-89 Ci
<LLD
<LLD
<LLD 1.42E-05 Sr-90 Ci
<LLD
<LLD 4.48E-06 6.20E-06 Cs-134 Ci
<LLD
<LLD
<LLD
<LLD Cs-137 Ci
<LLD
<LLD 2.99E-04 4.14E-04 I-131 Ci
<LLD
<LLD
<LLD
<LLD Co-60 Ci
<LLD
<LLD 1.92E-03 3.86E-03 Co-58 Ci
<LLD
<LLD
<LLD 8.68E-05 Fe-59 Ci
<LLD
<LLD
<LLD
<LLD Zn-65 Ci
<LLD
<LLD
<LLD
<LLD j
l Mn-54 Ci
<LLD
<LLD 5.36E-04 4.01E-04 Cr-51 Ci
<LLD
<LLD 1.16E-04 9.98E-04 Zr-95 Ci
<LLD
<LLD
<LLD
<LLD Nb-95 Ci
<LLD
<LLD
<LLD
<LLD Mo-99 Ci
<LLD
<LLD
<LLD
<LLD Ag-110m Ci
<LLD
<LLD
<LLD
<LLD Ba-140 Ci
<LLD
<LLD
<LLD
<LLD La-140 Ci
<LLD
<LLD
<LLD
<LLD Fe-55 Ci
<LLD
<LLD 7.70E-05 1.55E-04 Unidentified Ci
<LLD
<LLD
<LLD
<LLD Sb-124 Ci
<LLD
<LLD 2.58E-05
<LLD Sb-125 Ci
<LLD
<LLD
<LLD 6.49E-05 Total for Period Ci
<LLD
<LLD 2.98E-03 6.00E-03 (above)
Xe-133 Ci
<LLD
<LLD
<LLD
<LLD Xe-135 Ci
<LLD
<LLD
<LLD 1.96E-05
\\h3kM Prepared by:
b 4
Date:
7 7_-
y
!b V Approved by:
o Date:
18 1
4 EFFLUENT AND WASTE DISPOSAL SEMIANNUAL REPORT Supplemental Information Facility Guad Cities Nuclear Power Station July - December 1997 Licensee Cormionwealth Edison Comoany 1.
Regulatory Limits a.
For Noble Gases:
Dose rate 1.
Less than 500 mrem / year to the whole body.
- 2..Less than 3000 mrem / year to the skin.
Dose Gamma Radiation 1.
Less than or equal to 5 mrad / quarter.
2.
Less than or equal to 10 mrad / year.
Beta Radiation 1.
Less than or equal to 10 mrad / quarter.
2.
Less than or equal to 20 mrad / year.
b..c.
For Iodine-131, for Iodine-133, and for all radionuclides in particulate form with half-lives greater than 8 days.
Dose Rate 1.
Less than 1500 mrem / year i
Dose 1.
Less than or equal to 7.5 mrem / quarter 2.
Less than or equal to 15 mrem / year, d.
For Liquid i
Less than or equal to 3 mrem to the whole body during any calendar quarter.
Less than or equal to 10 mrem to any organ during any calendar
. quarter.
Less than or equal to 6 mrem to the whole body during any calendar year.
Less than or equal to 20 mrem to any organ during any calendar year.
S1htGR\\00698.Dhc
2.
Maximum Permissible Concentration a..b.,c.,
For fission and activation gases, iodines, and particulates with halflives greater than 8 days, allowable release limits are calculated by solving equations 10.1 and 10.2 from the Offsite Dose Calculation Manual. The alarm setpoint is conservatively set at approximately 10% of the 10CFR20 limit.
d.
For liquid effluents allowable release limits are calculated by solving equations 10.3 and 10.4 from the Offsite Dose Calculation manual. The MPC values used for the monitors were as follows:
radwaste discharge 4.96E-05 uC1/ml service water 1.0E-05 uCi/ml 3.
Average Energy The average gamma energy used to calculate the alarm setpoints for the noble gas monitors was 0.660 Mev for the Third quarter, and 0.553 Mev for the Fourth quarter.
4.
Measurements and Approximations of Total Radioactivity a.
Fission and Activation Gases:
b.
c.
Particulates:
The main chimney and reactor building ventilation exhaust systems are continually monitored for iodines and particulates. These samples are pulled every 7 days and analyzed by gamma isotopic.
The particulate papers are composited every 31 days and sent to a vendor for Sr 89-90 and gross al)ha analysis.
Noble gas grab samples are pulled and analyzed )y gamma isotopic weekly. Tritium samples are pulled and analyzed every month.
The continuous strip chart recorders for the monitors on the release points are reviewed monthly for spikes and the activity released is calculated. An additional calculated activity for noble gases is added to the Main chimney release each month. This calculation is done because most of the grab samples show less than the lower limit of detection due to the low amount of activity and the large dilution flow at the sample point.
The calculation takes into account the normal offgas train and the gland steam contribution to the release.
The average flow at the release points are used to calculate the curies released.
. S1MGR\\00698.DBC a
d.
Liquid Effluents The. river. discharge tanks are analyzed before discharge by gamma
. isotopic. A composite representative portion of this sample saved. This is composited with other discharges.that occurred every 31 days and is analyzed for tritium and gross alpha.
The batch composites are composited quarterly and sent to a vendor for Sr 89-90 and Fe 55. The discharge bay is sampled every 31 days
.and analyzed by gamma isotopic, for tritium and gross alpha.
It is sampled quarterly and sent to a vendor for Sr 89-90 and Fe'55 analysis.
. The tank volumes and activities are used to calculate the curies released for the River Discharge Tank..The total water released during the quarter and the activity is used.to calculate the diluted activity released at the discharge bay, from batch discharges.
e.
Estimated Total Error Percent The estimated total error percents were calculated by taking the square root of the sum of the squares of errors for sampling and measurement parameters. The estimated total error percent for the solid waste radwaste curies is 12.3%.
f.
Less than the lower limit of detection (<LLD).
Samples are analyzed such that the Technical Specification LLD requirements are met. When a nuclide is not detected during the quarter then <LLD is reported.
5.
Batch Releases a.
Liquid 1.
number of releases 15 2.
total time 15.957 minutes 3.
maximum time 1,135 minutes 4.
average time 1.064 Minutes 5.
minimum tine 945 minutes 6.
average stream flow, discharge 49.6 gpm, dilution 3.92E+05 gpm.
b.
Gaseous NONE
. 51MGR\\00698.DDC q.
m L6. Abnormal Releases a.
Gaseous
' 1.
- On July 14', ~1997 a reactor fueleleak developed on U-2.. The
~ leak was found and.successfully surpressed within a week after it first presented. The unit remained on-line' through September 27 1997,- at which time the appropriate fuel bundle was replaced - Overall, the effect on radiological effluents was minimal.
b.
Liquid NONE f
1 4
?
- 7 '
51MGR\\00698.DBC'-
i
Solid Radwaste Annual Quantities for NRC 1.21 Report (1) Annual total quantity of solid radwaste-1,543.14 cubic meters Annual Total radioactivity of solid waste-3.20 E3 Ci (2) Obtain an estimate of major radionuclide composition of solid waste H 2.39E+02 mci C-14 7.26E+02 mci Cr-51 9.12E+04 mci Mn-54 3.12E+05 mci Fe-55 6.51E+05 mci Co-58 4.54E+04 mci Co 60 1.97E+06 mCl Fe-59 1.92E+03 mci Ni-63 9.63E+03 mci Zn-65 4.00E+04 mci Sr-90 3.26E+02 mci Ag-110m 1.80E+00 mci
~ Sb-125 4.16E+00 mci Cs-137 6.83E+04 mci Co-144 5.62E+00 mci Pu-238 7.13E+00 mci Pu-239/40 7.51E-01 mci Pu-241 3.04E+02 mci Am-241 1.14E+01 mci Cm-242 2.44E+00 mci Cm-243/44 7.61E+00 mci (3) Disposition of solid waste shipments a) Shipments to Barnwell SC - 32 b) Shipments to Memphis TN-16 c) Shipments to Oak Ridge TN-12 (4) Disposition ofirradiated fuel shipments None -
CmEd QUAD CITIES STAtl3 Jamr$rth 1997 33 ft. VIE SG and VIE DIREGION 196-33 ft. DIfRREXIIAL TEMAT1!
NMR Of 259 FAT 10N5 = 1988 VMS ARE PRCEXT OCCIRREEE
- SIMILITY CLASSE5 -
SPEED
= V!E DIREGION CLASSE5 CLASS N N E EE E ESE SE SSE i 55W SV WSW W M N N 10hl EU NU SU X 55 E ES 101AL EU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 W.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 C SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 A R.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 L SS.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 M E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
. 00 E5.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.00 EU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 W.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 1 SU.00.00.00.00.05.00.00.05.00.00.05.05.00.00.00.00.20
.20
- I.45.15.30.05.10.10.15.25.15.15.50.25.25.35.20.35 3.77 3.77 3 55. 15.25.35.35.20.25.25.10. 5.25.15.35.30.70.45.20 4.78 4.78 E.10.15.20.15.45.20.50.15.05.30.10.30.30.10.!0.10 3.37 3.37 ES.00.00.5.15.40.50.30.20.5.00.10.00.00.05.00.05 1.86 1.86 13.98 EU.10.00.10.05.20.05.00.30.10.20.45.45.60.50.35.5 3.72 3.72 E.00.00.05.10.05.05.00.05.05.5.00.05.15.10.05.20.96
.96 4 SU.05.10.00.10.00.20.15.15.05.15.10.40.5.65.05.5 2.46 2.46
- R.50.75.80.86 1.31.75 1.11.86.65.05.70 1.36 3.82 5.33 3.07.96 22.89 22.89 7 55.20.05.05.65 1.01.96 1.06.60.50.60.96 1.71 1.01 1.41.65.30 11.72 11.72 E.00.00.05.20.00.55.5.25.35.35.05.00.00.05.00.05 2.16 2.16 ES.00.00.00.00.15 25.05.00.00.10.00.00.00.00.00.00.55
.55 44.47 EU.5.10.25.05.05.25.00.10.30.25.50.30 1.91 1.21.75.5 6.54 6.54 E.00.00.00.05.10.00.00.00.00.00.5.05.20.10.00.00.55
.55 8 SU.05.00.05.05.00.25.00.00.00.5.00.10.50.35.40.05 1.86 1.86 X.30.35.75.96 !.01 1.21.35.05.10.20.20.86 4.58 7.55 2.06.10 21.63 21.63 j
1 SS.05.10.00.15.10.60.20.05.45.70.50.35.30.35. 5.15 4.12 4.12 2 E.00.00.00.00.00.05.00.00.15.00.00.00.00.00.00.00.20
.20 ES.00.00.00.00.00.a.a.00.00.00.00.00.00.00.00.00.00
.00 1
34.91 EU.00.00.00.00.00.20.00.00.00.00.5.00.10.30.00.00. 5.65 l E.G.00.00.00.00.05.00.00.00.00.00.05.00.05.00.00.15
.15 3 50.00.00.00.00.00.00.00.00.00.00.10.00.35.30.00.00.75
.75 t.00.05.15.25.05.50.00.00.00.00.00.15 1.61 1.66.45.05 4.93 4.93 1 55.00.00.00.00.00.00.00.00.00.00.00.00.00.00.05.05.10
.10 8 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 j
ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 6.59
O' -
Cadd QUE ClilES STAilm Jamary-brd 1997 33 ft. Wie PEED and WIE DIECT13 1533 ft. DiffEERTIAL TDPEN SIE!UTY CLASSES -
PEED - - -
-- Wit D!ECilm CUSSES CLASS X K E - EE E ESE SE SSE S SW WH W W W W TOTAL EU E 50 i SS MS ES TOTAL EU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 1 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 9 SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 4.00.00.00.00.00.05.00.00.00.00.00.00.00.00.00.00.05
.05 2 SS.00.00.00.00.00.00.00.00.00.00.00.00 '.00.00.00.00.00
.00 4 MS.00.00.00.00.00.00.60.00.00.00.00.00.00.00.00.00.00
.00 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.05 EU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 6 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 i SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 I.00.00.00 ~.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 2 55.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 4 M5.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 ES.00.00.0.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.00 101 2.41 2,06 3.17 4.18 6.24 7.04 4.38 3.17 3.22 3.42 4.58 6.79 16.25 21.13 8.80 3.17 100.00 10.92 1.66 5.28 53.27 20.72 5.73 2.41 100.00 Wid Directie by Stdility i E E EE E ESE SE SSE 5 S2 WG W N W W TOTAL -$TEILIlY CLASSES-
.35.10.35.10. 5.50.00.40.40.45 1.01.75 2.62 2.01 1.11.50 10.92 Ertruly hstele
.00.00.05.15.15.10.00.05.05.05.05.15.35.25.05.20 1.'4 bdentely hstdle
.10.10.05.15. 5.45.15.20.05.20.25.55 1.11 1.31.45.10 5.28 Sli@tly hstele 1.26 1.31 2.01 2.11 3.47 2.62 1.61 1.16.91.40 1.41 2.52 10.26 14.89 5.78 1.46 53.27 butnl
.60.40.40 1.16 1.31 1.81 1.51.75 1.!] 1.56 1.61 2.41 1.61 2.46 1.21.70 20.72 Slightly Stdle
.10.15.25.35.45.80.75.40.55.65.15.30.30.15.20.15 5.73 Mdentely Stdle
.00.00.05.15.55.75.35.20.05.10.10.00.00.05.00.05 2.41 Extruly Stele Wind Directie by find Speed i M E EE E ESE SE SSE 5 59 2H W W W N TOTAL -WIE SPEED CLASSES-
.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 CALM
.91.55.91.70 1.!! 1.06 1.!!.75.50.70.91.96. 5 1.21.86.70 13.98 0.9 - 3.5 $
l
'.86.91 1.06 1.96 2.72 2.82 2.6? 2.!! 1.71 1.51 2.26 3.97 5.84 8.05 4.18 1.81 44.47 3.6 7.5 $
.65.55 1.06 1.26 2.5 !.36.55.20 1.01 1.21 1.5 1.66 7.49 9.E 3.27.55 34.91 7.6 12.5 mph
.00.05.15. 5.05.75.00.00.00.00 15.20 2.06 2.31.50.10 6.59 12.6 18.5 mph
.00.00.00.00.00.05.m.00.a.00.x.00.a.00.00.00.05 18.6 24.5 $
.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
> 24.5 sh I
Cdd 50 CITIES STAT'OR Jaaryerth 1997 296 ft. WlE SPE9 and WIE DIECTIM 296 33 ft. D!ffEENTIAL TDIGATWE RIODtOf 085RVAil0E 2101 VALUES AE PIEENT OCONtEEE
- ------ Siellm CLASSE5 --- -----
y[g.......
............. V!E DIECilm CLASSE5 - - - ------ - ------
CLASS I E E EE E ESE SE SSE 5 52 SW USW V N W W TOTAL G W 2 N 55 E ES TOTAL D.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 W.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 C 2.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 A i.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 L $5.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 M E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 -
.00 L
ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.00 0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 W.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 1 2.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 I.14.00.19.05.05.00.00.05.00.00.14.00.14.05.10.05.95
.95 3 55.05.05.00.05.05.05.00.00.10. 5.00.19.00.00.05.00.62
.62 E.00.05.00.10.00.05.05.05.05.05.05.5.05.00.00.05.57
.57 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 2.14 D.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 W.6.00.00.05.00.05.00.05.05.05.05.00.10.10.05.00.57
.57 4 2.00.00.10.14.10.05.05.05.05.00.14.05.14.05.10.10 1.09 1.09 X.48.4.62.19.43.10.57.14.43.29.48.57.10.29.48.33 5.95 5.95 7 $$.19.05.14.10.19.14.14.10.05.19.19.14.19.24.19.00 2.24 2.24 "S. 00.00.00.00.10.19.19.10.33.05.10.00.10.00. 5.10 1.29
! 29 ES.00.00.00.00.00.00.05.00.00.05.00.05.00.00.00.00.14
.14 11.28 EU.00.00.05.00.00.00.00.00.00.10.10.14.14.05.10.10.76.76 E.14.05.14.5.05.19.00.00.00.05.05.10.33.19.19.10 1.62 1.62 8 2.05.00.14.00.10.19.00.19.05.00.05.14.48.19.19.29 2.05 2.05 N.4.43.71.38 1.29.4.52.52.76.19.52 1.05 1.52 3.05 3.19.95 16.04 16.04 1 55.24.19.29.14.48. 5.29.29.24.48.29.43.24.48.76.57 5.43 5.43 2 E.05.6.05.05.33.10.38.24.19.10.14.00.05.14.10.00 1.95 1.95 ES.00.00.00.00.10.00.05.10.10.05.05.00.10.10.00.00.62
.62
- 28. 4 5.00.05.00.00. 5.10.00.14.00.14.00.00.05.24.19.00.95.95
- 1 W.00.10.05.00.00.5.00.10.00.00 '.19.5.38.38.14.05 1.48 1.48 3 2.00.05.00.00.10.19.00.00.19.00.10.24.52.52.33.05 2.28 2.28 I.29.19. 4.57 1.19 1.05 1.19.48.43.24.33.71 1.90 7.47 2.67.62 19.80 19.80 1 55.14. 5.00.24 1.05.67.il.76.29.86 1.05.76.86.48.24.24 8.47 8.47 8 E.00.00.00.14.10.10.24.29.05.29.10.05.10.00.00.00 1.43 1.43 ES 00.00.00.00.00. 00.05.14.10.10.00.00.05.00 ;00.00.43
.43 34.84
Cald 50 CITIES STAllh Jaary#ch 1997
)
296 ft. W!E SPEG ad WIE DIETION 296 33 ft. DiffaEXI!EIDPRATRE I
SPEED -- -- ---- - - -- - -- - M DIElla HES --
- -- --- Sieltlif CLASES - -
CLASS. l. E E EE E ESE SE SSE S SW 2 W2 V N W W TOTE R El 2 1
$$ E ES TOTAL G.00.00.00.00.00.00.5.00.10.10.05.00.00.05.05.00.38. 2 1 E.00.00.00.00.00.10.5.00.00.00.10.05.00.14.10.00.52
.52 9 2.00.00.00. 2.00.05.00.00.00.05.00.00.19.14.00.00.43
.43
- I.00.10.43.62.43.67.14.05.19.29.29.43 1.71 3.71 2.05.14 11.23 11.23 2 SS.14.00.00.00. 5.48.62.29.76.33.57.33.24.19.00. 5 4. 5 4.05 4 E.00.00.00.00.00.10.14.00 -.10.29.14.00.00.00.00.00.76
.76 ES.00.00.00.00.00.00.00.00.00.05.00.00.00.00.00.00.05
.05 17.42 5.00.00.00.00.00.00.00.00.05.00.00.00.00.00.00.00.05.05 6 Ri.00.00.00.00.00.00.00.05.10.00.10.00.00.00.00.00.24
.24 1 2.00.00.00.00.00.10.00.00.00.00.05.00.00.00.00.00.14
.14 I.05.00.00.05.00.19.00.00.05.00.00.00 1.57 1.86.48.00 4.24 4.24 2 SS.00.00.00.00.00.00.00.00.33.62.19.00.00.00.00.05 1.19 1.19 4 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 5.5 TOT !.481.86 3.2 2.90 6.19 5.43 5.57 4.14 5.09 5.00 5.57 5.5211.23 20.0911.76 3.81100.00 2.14 4.43 6.00 58.2121.99 6.001.24100.00 Wid Directie by Stdllity i K E EE E ESE SE SSE 5 $2 28 W N W N TOTAL STA81LI1Y CLASSES-
.00.05.05.00.05.10.05.14.14.33.14.14.19.33.33.10 2.14 Extremly hstdle
.19.14.19.10. 5.38.05.19.14.10.48.19.81.81.48.14 4.43 bderately thstdle
.05.05.24.14.29.57.05.24.29.05.33.43 1.33.90.62.43 6.00 Slightly hstele 1.43 1.19 2.43 1.86 3.38 2.48 2.43 1.24 1.86 1.00 1.76 2.76 6.95 16.42 8.95 2.09 58.21 kutral
.76.33.43.52 1.81 1. 2 1.86 1.43 !.16 2.52 2.28 1.06 1.52 1.38 1.24.90 21.99 Slightly Stdle
.05.10.05.29.52.52 1.00.67.71.76.52.10.29.14.14.14 6.00 4derately Stdle
.00.00.00.00.10.M.14.24.19.24.05.05.14.10.00.00 1.24 Extreely Stele Wind Directie by Wind Speed X K E EE E ESE SE SSE $ $2 2N W N E N TOTAL WIE SPEED CLASSES-
)
.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 CALR
.19 ~.10.19.19 '.10.10.05.10.14.10.19.24.19.05.14.10 2.14 0.93.5@
.71.52.86.48.81.52 1.00.43.90.62.95.81.62.67.86.52 11.28 3.6 7.5 sh
.95.71 1.38.62 1.33 1.00 1.24 1.33 1.33.95 1.19 1. 5 2.86 4.19 4.52 2.00 28.46 7.6 !!.5 $
.43.43.52.95 2.48 2.14 2.28 1.90 1.05 1.62 1.76 1.81 3.86 9.09 3.57. % 34.84 12.6 18.5 $
.14.10 43.62.48 1.38 1.00.33 1.14 1.09 1.14.81 2.14 4.24 2.19.19 17.42 18.6 24.5 $
.5.00.00.05.00.29.0L.5.52.62.33.00 1.57 1.86.48.5 5.5
> 24.5 $
I j
Ca[d M CIT][5 STAil3 Apri14u 1997 33 ft. WIE SPIED nd VIE DIECil3 lE33 ft. DIFFR[lilAL T[rIAT2I DE[R Of 085RVAil35 2164 VALUES ARI PEEENT DCC$ EKE VIE DIEil3 CLASSE5 -
- 5TABILITY CLASSE5 - ---
SPEID ---
CLASS N El E [E [ [S[ 5[ 55[ 5 SSW SW WW W N E N 101Al [U E 50 N SS E [5 TOTAL EU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 C SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 A N.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 L 15.00.00.00.00.00.00.00.d.00.00.00.00.00.00.00.00.00
.00 M RS.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
[5.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.00
[U.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 W.00.00.00.00.00.00.00.00.00.00.00.00.00.00.05.00.05
.05 1 SU.00.00.00.00.00.00.00.00.05.05.00.00.00.05.05.00.!B
.18 N.6.00.00.23.28.42.28.23.14.14.47.37.23.33.19.05 3.47 3.47 3 55.46.32.60.32.79.60.60.65.60.65.46.55.37.69.09.32 8.09 8.09 E.29.53 1.01.63.58 1.49 1.01.67.67.43.39.39.19 1.01.39.19 10.07 10.07
[5.00.20.35.50.80 1.59.75.65.10.25.25.30.35.40. 5.00 6.52 6.52 28.37
[U.42.28.18.32.28.00.6.32.37.42.92.60.55 1.02.88.32 6.98 6.98 l
E.05.18.18.05.00.14.05.09.05.05.32.14.14.28.00.18 1.89 1.89 1
4 50.09.18.14.23.14.14.05.28.23.23.92.14.23.46.23.09 3.79 3.79 N.60.651.061.251.481.20.60.74.46.51 1.25.74.6.55.65.51 13.03 13.03 7 55.65.23 1.39 1.57 1.16 1.02.79.28.23 1.20 1.25.79 1.11 1.20.55.51 13.91 13.91 E.05.05.32.09.05.42.14.18.09.09.05.00.00.14.18.09 1.94 1.94
[5.00.00.00.00.00.60.09.00.00.00.00.00.00.00.00.00.69
.69 42.24
[U.14.37.32.42.32.28.32.28.09.42.83.18.37.92.97 1.02 7.26 7.26 l
E.00.5.05.14.14.09.5.00.00.05.14.00.00.05.14.5
.97
.97 l
8 SU.05.18.18.14.09.09.00.05.00.5.14.05.14.05.09.09 1.39 1.39 l
N.65.14.92 1.89.74.37.6.18.09.32.55.23.23 1.48 1.29.51 10.30 10.30 1 55.00.00.09.55.32.09.23.05.09.46 1.25.09.09.05.14. 5 3.56 3.56 1
2 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
[5.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 23.48 l
[U.00.5.23.18.09.00.00.00.00.00.00. 5.09.46.51.05 1.71 1.71
)
i E.a.00.e.00.05.00.00.00.00.00.00.05.e.it.5.n.28
.28 3 5U.00.00.00.5.05.00.00.00.00.00.00.5.09.18.09.00.51
.51 N.05.00.14.32.00.09.14.00.00.00.05.09.32 1.06.32.05 2.63 2.63 I 55.t0.00.00.00.00.05.00.5.05.00.5.00.00.00.09.00.2B
.28 l
8 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
[5.00.60.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 5.41 4
i
)
Cdd DE UT1[5 STATIM April-Jne IN7 33 ft. Ul2 SPEIO ad WIS DIECTIR 196-33 ft. Diff[BilAL i[fERAT8[
-- ---- SIELIU CLASE3 ------ -
y((o.................
. yle DIEGIN CLASES - - - - -- --
CLASS I E E [E-[ [S[ E $5[ S $2 2N V N N N TOTAL [U W W 8 SS MS ES TOTAL
[U.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
~
1 E.00.00.00.00. 00.00.00.00.00.00 00.00.00.00 '.00.00.00
.00 9 2.00.00.00.00.00.00.00.00. -.00.00.00.00.00.00.00.00.00
.00 I.00.00.00.00.00.00.00.00.00.00.05.23.18.00.00.00
.N
.4
! $$.00. 00.00.00.00.00.00.00.00.00.00.00.00.00 '.00.00.00
.00 4 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
[5.00.00.00 00.00.00.00.00.00.00. 00.00.00.00.00.00.00
.00
.r4
[U.00 ~.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 6 2.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 i SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 I,.00. 00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 2 SS.00.00.00.00.06.00.00.00.00.00.00.00.05.00.00.00.05
.05 4 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
[5.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.05 1013.57 3.4 7.18 8.89 7.M 8.68 5.87 4.70 3.2 5.319.33 5.03 5.6410.617.00 4.08100.0015.94 3.19 5.87 29.90 25.212.017.21 100.00 i
Wid Directin by Stellity X K E [E [ [S[ SE SSE S SW WN V N W N TOTAL 5TA81 Lily CLASES-
.5!. 6.74.92. 0.28.42.60 4.83 1.76.83 1.02 2.40 2.36 1.39 15.94 [xtruely hstele l
.05.28.23.18.18.23.09.09.05.09. 4.18.14. 4.23.23 3.19 bderately hstdle
.14.37.32.42.28.23.05.32.28.32 1.06.23. 4.74. 4.18 5.87 Slightly hstdle 1.39.79 2.13 3.70 2.50 2.09 1.71 1.16.70.97 2.36 1.67 1,67 3.52 2.45 1.11 29.90 Nutral 1.11.55 2.08 2.45 2.26 1.76 1.62 1.02.97 2.31 3.00 1.43 1.62 1.H.2.18 25.88 Slightly Stele
.M.581.M.72.621.91 1.15.86.77.53.43.39.391.15.57.29 !!.01 bderately Stdle l
.00.20.35.50.80 2.19 -.M.65.10.25.25.30.35.40.05.00 7.21 [xtruely Stele Wid Directin by Wid heed i E E [E [ [S[ SE SE S SW WH V N N N TOTAL -VIE SPEED CLASS [S-
.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 CALM
.N 1.05 1.96 1.18 2.H 4.11 2.64 2.20 1.56 1.52 1.56 1.61 1.M !.4.81.56 28.37 0.9 3.5 $
1.s 1.57 3.28 3.513.10 3.51 1.m 1.s 1.43 2.50 ul 2.e us 3.74 2.50 ul 42.24 3.6 - 7.5 e
. 83.79 1.57 3.14 1.62.92 1.29.55.28 1.29 2.91.55.83 2.54 2.63 1.71 23. #
7.6 !!.5 mph
. 5. 5.37. 55.18.14.14. 5.05.00.09.!3.51 1.85 1.06.09 5.41
!!.6 - 18.5 iph
.00.00.00.00.e.a.00.00.00.00.05.23.18.s.e.00
.4 18.6 - 24.5 5
.00 00.00.00.00.00.00. 00.00.00.00.00.05.00.00.00.05
> 24.5 sph
Cas!d @AD CIT!E5 stall 0N April-he 1997 296 ft. W!E SPEG and W!E DIECT!3 296 33 ft. D!ffER371AL TEWWE IDER Of DESEhAll35 = 2145 VALUE5 ARE PEEST OCCME SPED -
~------- V!E DIRECi10N CLASSES
= STABILITY CLASSE5 -
CLASS I E E [E E ESE SE $5E 5 55V 9 VW W N hv N TOTAL B E SU N SS N5 [5 TOTAL G.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 m.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
( SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 A I.00.00.00.00.00.00.00.00.00.00.00.00.00.00.:0.00.00
.00 L 55.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 N E.00.00.00.00.00.00.00.00.T.00.00.00.00.00.00.00.00
.00 E5.00.00.00.00.00.00.00.00.00.00.00.8.00.00.00.00.00
.00
.00 B.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 m.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 1 SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 t.09.05.00.00.05.09.14.09.14.14.09.5.09.09.05.09 1.31 1.31 3 55.18.00.00.06.00.12.00.00.00.00.00.06.00.00.00.00.42
.42 M5.6.14.05.00.6.05.00.5.05.00.00.09.00.00.00.5
.65
.65 IS.00.00.00.00. 5.00.00.00.00.06.00.00.00.00.00.06.19
.19 2.56 0.00.14.00.05.00.00.00.00.00.00.00.05.05. 5.05.00.37.37 5.14.09.09.05.05.09.00.00.00.09.14.14.23.H.09.09 1.40 1.40 4 5U.09.19.23.00.05.14.00.05.09.28.33.09.19.37.00.23 2.33 2.33
- t.33.42.23.51.23.33.42.42.42.51.75.37.42.28.09.09 5.83 5.83 7 55.19.37.33.14.65.14.14.23.28.42.23.19.19.14.23.09 3.96 3.96 E.09.19.00.09.23.05.14.33.09.09.00.14.09.05.09.14 1.82 1.82 ES.00.00.00.00.00.05.09.09.05.5.05.05.09.05.00.00.56
.56 16.27 EU.09.28.23.14.5.09.14.19.19.19.14.5.14.28.19.28 2.70 2.70 t.19.14.14.14.14.19.09.14.09.14.23.09.09.28.19.28 2.56 2.56 8 50.14.19.14.14.19.05.00.28. 5,14.37. 5.09.23.05.23 2.38 2.38
- I.33.51.84.56 1.11.65.19.37.37.65.70.23.23.70.37.28 8.30 8.30 1 55.33.37.70.98.98.33.75.70.65.56.47.42.56.70.33.33 9.14 9.14 2 E.28.H.H.09.37.33.33.93.42.47.05.23.19.14.37.23 4.62 4.62 ES.00.00.00.00.00.09.14.37.19.19.00.05.09.09.14.00 1.35 1.35 31.05 0.00.14.14. 5.14.09.05.00.19.33.23.09.09.37.33.09 2.33 2.33 1 m.00.00.09.05.19.05.8.14.09.09.14.00.05.09.09.05 1.!!
1.21 3 SU.00.00.14.09.05.05.09.6.09.14.19.05.00.05.23.05 1.26 1.26
- I.51.42.98 1.63.84.47.51.37.28.37.47.79.23.93.84.70 10.35 10.35 1 55.05.19.65 1.17 1.07.93.47.42.33 1.03.75.56.47.98.28.33 0.65 9.65 8 E.09.19.23.14.14.19.65 1.17.65.56.09.00.05.5.14.14 4.52 4.52 ES.00.00.00.00.00.5.14.09.37.5.05.00.00.00.00.00.79
.79 30.12
(mEd 50 CITIES STAT 13 Aprildne 1997 296 ft. V!E PEB ad V!E DIECTIS 296-33 ft. DIffEENilAL TERRATE
-- --- - STEllm CLASES ------- --
. Wlt DIECIM CLASES ------
y[g.._
CLASS I E E EE E ESE SE SSE $ SW WH W N W N TOTAL S E Su i SS E ES TOTAL G.00.09.14.00.00.00.00.19.09.H.05.00.05.61.51.09 1.91 1.91 1 E.00.05.00.33.05.00.00.00.00.19.19.00.05.33.28.05 1,49 1.49 9 $U.00.5.00.19.14.00.5.00.00.5.00.00.5.19.14.05.93
.93 t.5.00.42 1.3.37.09.56.28.H.47.70.09.19 1.03.79.23 6.67 6.67 2 SS.00.00.19.61.14.09.09.05.23 1. 0.42.09.23.00.09.00 3.25 3.26 4 E.00.00.00.00.00.00.00.05.19.09.00.00.00.00.00.00.33
.33 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.H
.00 14.59 0.00.00.05.00.00.00.00.00.00.00.00.00.05.05.14.00.28.28 6 E.00.00.05.05.00.00.00.00.00.00.00.00.00.05.05.00.19
.19 i SU.00.00.00.00.00.00.00.00.00.09.00.00.5.33.05.00.56
.56 N.00.00.00.05.05.14.5.5.H.37.28.28.75 1.40.31.05 4.01 4.01 2 SS.00.00.00.05.00.05.00.05.05.19.00.00.00.00.00.00.37
.37
' 4 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 5.41 TOT 3.30 4.29 6.15 8.59 7.66 5.015.36 7.18 5.83 9.15 7.5 4.40 5.210.02 6.57 4.30100.00 7.60 6.85 7.46 X.46 26.8111.93 2.5100.00 WiW Directie by Stdility X K E EE E ESE SE SSE $ SW WN W N W N TOTAL -STABILITY CLASSES-
.09.65.56.!3.23.19.19.37.47.61.42.19.37 1.35 1 21.47 7.60 Extraely kstdle
.33.28.37.61.42.33.19.28.19.51.70.23.42.M.70.47 6.85 Nederately kstele
.23.42.51.42.42.23.14.37.23.75.89.23.42 1.17.47. % 7.46 Slightly kstele 1.351.40 2.47 4.012.N 1.771.91 1.01.40 2.52 2.981.861,914.43 2.521.($ 36.46 hatral
.74.931.86 3.00 2.N 1.661.451.451,54 3.221.861.321.451.82.93.75 26.81 Slightly Stdle
.56.61.37.33.N.61 1.12 2.52 1.40 1.!!.14.47.33.28.61.56 11.93 Nederately Stdle
.00.00.00.00.06.23.37.56.61.34.09.09.19.14.14.06 2.89 Extreely Stele Wid Directie by Wid Speed i E E EE E ESE SE SSE $ SW WN W N W N TOTAL -WIE SPEG CLASSES-
.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 CALM
.37.19.05.06.20.26.14.14.19.20.M.25.5.09.05.20 2.56 0.9 3.5 $
.N 1.40.5.N 1.!!.79.791.12.931.451,491.031.261.03.56.6516.27 3.6 - 7.5 $
l.351.592.142.053.21.721.02.981.962.331.961.171.402.421.01.011.05 7.6 - 12.5 $
. 6.93 2.24 3.12 2.42 1.86 2.00 2.24 2.00 2.56 1.91 1.49.89 2.52 1.91 1.35 30.12 12.6 - 18.5 $
. s.19.75 2. 2.70.19.70.56.61 1.96 1.35.19.56 2.14 1.82.42 14.59 18.6 - 24.5 $
.00.00.M.14.05.19,09.14.14.6.28.28.89 1.82.61.05 5.41
> 24.5 $
Culd M C111[5 STAil3 My-Septaber 1997 33 ft. W:E 9EG nd f!E DIRECT!3 196 33 ft. DIffamilAl TEMATW[
WER Of 085RVAllRS = 2208 VALUES M[ PRCRT OCC$R[
p[g.
.......................... VIE DMCilm (LASSE5 - -- -
- -- STEllliY CLASSE5 -- - -- -
CLASS N N E [E [ [5[ 5[ 55[ 5 55W 9 V5W V N W W TOTAL EU W SU N 55 E [5 TOTAL
[U.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 W.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
[ 50.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 A N.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 L $5.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 N E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
[5.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.00
[U.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 1 SU.00.00.00.00.00.00.00.00.00.00.00.00.00.09.00.00.09
.09 N.54.05.32.36.45.09.14.36.6.14.36.32.72.32.41.32 4.98 4.98 3 55.6B.23.731.361.U l.32.68.68.55.18.591.00.59.95.U.41 !!.50 12.50 E.50.78.60.92 1.10 1.97.78.83.37.50.18.28.14.60.73.73 11.01 11.01
[5.26.52.67.62 1.80 2.01 1.39.62. %.15.15.15.26.67.21.26 10.10 10.10 38.68
[U.27.09.09.00.00.00.23.45.14.14.32.91 1.09.59.27.27 4.85 4.85 2.09.00. 6.05.09.00. 6.32.05. 6.14.36.09.14.23.14 1.86 1.86 4 $U.27.14.18.23.23.05.23.45.18.14.50.41.27.36.23.36 4.21 4.21
. N 1.00.45 1.54 2.45 2.04 1.81 1.40 1.99 1.04 1.31 1.31 1.13.72.68 1.22.58 20.79 20.79 7 55 1.18.45 1.40 1.13 1.00 1.00.82.72.86.95 1.86 1.81.45 1.!! 1.49 1.13 17.48 17.48 E.18.23.32.09.00.14.14.05.09.18.27.09.00.H.14.23 2.22 2.22
[5.00.09.00. 6.00.14.05.00.00.00.00.00.00.00.00.00.32
.32 51.72
[U.36.18.36.H.05.05.00.05.00.05.05.14.18.27.32.27 2.40 2.40 m.14.09.18.05.6.00.00.05.00.00.00.00.5.05.00.5
.68
.68 8 $U.18.05.14.00.00.00.00.00.09.00.14.00.09.18.14.09 1.09 1.H N.45.5.59.14.05.00.00.09.14.23.23.14.18.50.18.18 3.13 3.13 155.09.00.H.05.00.00.00.05.05.27.41.23.05.41.09.18 1.95 1.95 1
2 6.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
[5.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 9.24 IU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 1 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 3 SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 N.05.00.00.00.00.00.00.00.00.00.00.00.14.18.00.00.36
.36 1 55.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 8 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
[5.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.36 j
Cadd Que EITIES STATION hly Septeer 1997 o
33 ft. M SPEB ad Ult DIECitt 196 33 ft. DiffENIAL TEMAilRE
- --- SMLITY MSES -
y[g............
M DIE 10N MHS CLASS I NE E EE E EH E SSE $ S2 9N W W W N TOTAL H E 2 i SS E ES TOTAL EU.00.00.00.00.00.00,.00.00.00.00.00.00.00.00.00.00.00.00 1 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 9 2.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 I.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 2 55.00.00.00.00.00.00.00.00.00.00.00.E.00.00.00.00.00 -
.00 4 MS.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 00
.00
[$. 00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.00 D.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 -.00 6 W.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 1 2.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 I.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 2 SS.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 4 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.00 1016.24 3.X 7.25 7.56 8.62 8.56 5.93 6.70 3.99 4.28 6.50 6.96 5.02 7.29 6.42 5.30100.00 7.5 2.54 5.39 29.26 31.9313.2210.42100.00 Wid Directiody Stdility i E E EE ! ESE SE SSE 5 $2 2N W N W W TOTAL STABilllY CLASSES-
.63.27.45.09.05.05.23.50.14.18.36 1.04 1.27.86.59.54 7.25 Extruely kstdle
.23.09.23.09.14.00.09.M.05.05.14.M.14.18.23.18 2.54 bderately kstdle
.45.18.32.23.23.05.23.45.27.14.63.41.36.63.36.45 5.39 Sliptly kstdle 2.04.54 2.45 2.H 2.541.901.54 2.451.271.21.901.591.771.21.81 1.18 29.26 hatral 1.95.E 2.22 2.54 2.77 2.31 1.501.451.451.40 2.86 3.041.09 2.58 !.* 1.72 31.93 Sliptly Stdle
.69 1.01.91 1.01 1.10 2.11.92.87.46.69.46.37.14.69.d7.96 13.22 Moderately Stdle
.26.61.67.66 1.80 2.15 1.44.62.M.15.15.15.26.67.21.26 10.42 Extruely Stdle WiW Directiody Wid Sped i K E EE E ESE SE SSE $ SW 9N W M N N TOTAL
-H PEG CLASSES-
.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 CA1M 1.991.57 2.313.26 5.13 5.39 2.99 2.491.X.981.291.751.712.0 2.121.72 33.2 0.9 - 3.5 $
!.991.45 3.58 3.99 3.35 3.13 2.H 3.99 2.% 2.76 4.39 4.712.63 3.08 3.58 2.8151.72 3.6 7.5 $
l.22.36 1.M.32.14.05.00.23.27.54.82.50.54 1.40.72.77 9.24 7.6 12.5 $
.05.00.00.00.00.00.00.00.00.00.00.00.14.18.00.00.36 12.6 18.5 $
.00.a.00.a.00.00.a.00.00.00.e.2.00.00.00.00.00 18.6 24.5 $
.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
> 24.5 $
1 r
i i
CmEd QUAD UTIES STATIM July Septaber 1997 i
296 ft. M 9ED ad M DIRECil3 296 33 ft. DIFFEEIR TDFEMRE j
i M 7 OB53 VAT 135 2037 I
VRUES ARE PERCDil DCCCEEE I
SPEED --
- M DIRECil3 QASSES ---
- STABILITY EASSES CLAS5 I E E [E E ESE SE SSE 5 SSW SW (J V N W R 10iR [U E SU N 55 MS [5 10TR i
EU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 C SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 A I.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 L 55.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 M E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.00 EU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 MV.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 1 SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
- N.34.15.05.10.15.00.00.5.00.00.10.15.25.10.15.25 1.82 1.82 3 $$.05.05.00.00.00.00.05.00.00.00.00.10.05.05.00.05.39
.39 E.00.00.06.12.06.00.06.06.06.00.00.06.00.06.00.00.54
.54 ES.00.00.00.10.00.05.00.10.10.10.05.00.00.05.00.5
.59
.59 3.34 EU.00.00.00.00.00.00.00.00.00.05.00.00.00.00.00.00.05.05 E.00.00.00.10.05.00.05.10.00.05.15.20.05.10.05.05.93
.93 4 50.20.05.10.10.05.05.10. 5.10.05.25.10.25.15.25. 5 2.26 2.26
- X.9.25.H 1.47 2.11.98.0 1.13.44.44.6.39.6.29.6.44 11.6
- 11. 6 7 55.05.25. 5.25. 6.20. 5.34.34.34.25.20.10.20.10.05 3.63 3.63 E.25.00.20.20.44.20.20.05.5.05.15.00.10.05.20.25 2.36 2.36 f5.05.05.05.05 10.10.00.10.29.05.29.05.05.00.00.15 1.37 1.37 22.09
[U.15.5.10.5.00.05.15.15.05.00.05.05.10.05.5.15 1.37 1.37 2. 5.10.25.10.15.00.10.34.05.00.00.54.29.20.10.!0 2.55 2.55 8 SU.5.15.5.10.10.20.29.59.10.20.10.29.15.20.15.20 3.29 3.29 N 1.08.34 1.72 1.67.79 1.77.54.93.64.59.88.54.29.64.20.74 13.35 13.35 155.59.29.29.59 1.37.0 1.08.54.64.9.64.39.6.20.B.93 9.92 9.92 2 E.39.6.88.54.59.0.54 1.18.88.34.20.5.20.15.10.10 7.31 7.31
[5.00.20.05.10.10.15.00. 5.29.05. 5.00.00.00.00.00 1.42 1.42 39.22 9.00.00. 5.05.00.00.00. 5.00.00.00.10.00.05.20.20 1.08 1.08 1 E.20.00.25.5.00.05.00.05.10.05.00.15.00.05.15.15 1.23 1.23 3 SU.20.10.15.00.00.00.00.10.10.10.05.5.05.5.05.05 1.03 1.03 N.64.25.83.44.10.20.05.59.64.83.34.39.54.0 1.13.34 8.00 8.00 1 55.39.54.64.49.44.29.79.88.98 1.28.98.74. 9.54.88.88 11.34 11.34 8 NS.44.20.20.29.5.54.93.88.20.4.10.15.05.05.00.10 4.81 4.81
[5.10.05.00.00.00.10.25.39.64.44.00. 5.05.00.00.00 2.06 2.06 29.55 1
Cdd Qu@ CITIES stall 0N July-Septeder 1997 296 ft. U SPEG ad M DIETIOR 296 33 ft. D!ffERIAL TEMNE
STE!LITY CLASSE5 -
y[g.
............. WIE MCil0N CLASSE5 -
CLASS X E E EE I ESE SE SSE 5 SW WG W N W N TOTAL B E SU i. 55 E IS TMAL IU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 ~.00 1 E.00.00.00.00.00.00.00.00.00.00.00.00.10.15.00.00.25
.25 9 50.00.00.00.00.00.00.00.00.00.00.00.00.05.05. 5.00.15
.15 N.10.00.15.00.00.00.00.10.25.10.10.05.20.M.15.15 1,67 1.67 2 55.00.00. 5.00.00.05.00.10.39.64. 5 49.29.29.15.05 2.75 2.75 4 M5.00.00.00.00.00.00.05.05.05.00.00.05.00.00.00.05
.5
.5 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 5.06 IO.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 6 MV.00.00.00.00.00.00.00.00.00.00.00.00.10.00.00.00.10
.10 i SU.00.00.00.00.00.00.00.00.00.00.00.00.05.00.00.00.05
.05
- N.00.00.00.00.00.00.00.00.00.00.00.00.20.29.00.00.49
.49 2 55.00.00.00.00.00.00.00.00.00.00.05.00.00.05.00.00.10
.10 4 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 IS.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.74 1016.38 3.73 7.42 6.94 7.33 6.33 6.15 9.53 7.37 6.77 5.69 5.315.115.07 5.15 5.69100.00 2.50 5.06 6.D 36.82 28.1315.27 5.45100.00 Wind Directie by Stability i E E EE i ESE SE SSE 5 SW WG W N N N TOTAL -5TABILITY CLASSES-
.15.25.34.10.00.05.15.39.05.05.05.15.10.10.25.34 2.50 fitremely hstable
.44.10. 6. 5.20.05.15.49.15.10.15.88.54.49.29.29 5.06 bderately Unstable
.64.29.6.20.15.25.39.93.29.34.39.44.54.44.49.49 6.D Slightly Unstable
- 2. 5.98 3.44 3.68 3.14 2.95 1.28 2.80 1.96 1.96 1.91 1.52 1.95 2.36 2.11 1.91 36.82 butral 1.08 1.13 1.23 1.33 2.31 1.23 2.16 1.87 !.36 2. 5 2.16 1.91 1.52 1.33 1.72 1.96 28.13 Slightly Stable 1.08.6 1.M l.15 1.34 1.42 1.78 2.22 1.24.83.44.31.M.31.29.6 15.27 Noderately Stable
.15.29.10. 5.20.39. 5.83 1.33.64.59.10.10.05.00.20 5.45 Ixtremely Stable Wid Directie by Wim! Speed i E E [E i (SE SE SSE 5 52 WG W N W M TOTAL -WIE SPED CLASSES-
.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 CALM
.39.20.11.31.21.05.11.21.16.10.15.31.29.26.15.34 3.34 0.9 3.5 sph 1.23.59 1.28 2.16 3.24 1.52 1.28 1.96 1.23 1.03 1.57.93 1.03.79 1.08 1.18 22.09 3.6 7.5 mph 2.70 1.82 3.53 3.14 3.09 3.53 2.70 3.98 2.65 1.77 2.11 1.87 1.52 1.42 1.18 2.21 39.22 7.6 12.5 sph 1.96 1.13 2.31 1.33.79 1.18 2.01 3.14 2. 5 3.14 1.47 1.62 1.28 1.42 2.41 1.72 29.55 12.6 18.5 sph
.10.00.20.00.00.05.05.25.69.74.M.59.64.83.M.5 5.06 18.6 24.5 sph
.00.00. 00.00.00.00.00.00.00.00.05.00.34.34 00.00.74
> 24.5 mph j
a.
Cdd QUID CITIES STATION Ottaber-Decder 1997 33 ft. M SPEED aad W!E O!ECTION
-196 33 ft. OlffRENT!E THATIE EllB Of 0858VATl0N5 2121 MS E PEEENT OCCEEEE g............................. M MC110R CLASE5 -- ---- ----- -- --- - ---- -- -
- - ST21L11Y CLASE5 - - ----
CLASS I K E EE E' ESE SE SSE 5 SSW 9G W N E N TOTAL EU E SU R 55 E El TOTE
' G.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 t.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 C SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 A I.00.00 '.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 L 55.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 M E.00.00.00.00.00.00.00.00.00.00.05.00.00.00.00.00.05
.05 E5.00.00.00.05.00.00.00.00.00.00.00.00.00.00.00.00.05
.05
.09 G.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 1 SU.00.00.00.00.00.00.00.00.00.00.00.00.5.00.00.00.05
.05 I.24.24.24.33.33.24.10.24.33.14.24.29.52.24.81.33 4. 5 4.86 3 55.28.47.14.47.76.71.47. 5.38.47.47. 5.81 1.37.99.90 10.42 10.42 E.24.20.24.29.20.44.64.93.59.69.15.29.34.54.29.39 6.4 6.4 ES.15.30.15.20.84 1,68.N.69.45.35.10.05.20.40.15.15 6.79 6.79 28.57 G.00.00.00.00.00.00.00.00.00.05.52.05.14.05.05.19 1.04 1.04 E.00.00.00.00.00.00.00.00.00.14.19.00.19.14.05.05.75
.75 4 50.09. 5.00.00.00.05 '.09.05.00.05.24.00.42.19.14.05 1. 4 1.4 I.99.42 1.23 1.93 1.56.47 1.08.41.66. 0 1.04 1. 4 2.78 4.38 2.40 1.70 23.43 23.43 7 55 1.08.71 1.4.N -.94.71 1.13 1.37.5 1.93 2.2 1.23 2.78 2.07 2.17 1.04 23.29 23.29 E.5.00.00.00.09.33.33.19.24.57.28.00.00.14.09.00 2.36 2.36 5.00.00.00.00.00.57.00.00.00.00.00.00.00.00.05.00.61
.61 52.95 G.00.00.00.00.00.00.00.00.00.00.05.05.05.24.14.09.61.61 E.00.00.00.05.00.00.00.00.00.00.09.00 -.00.14.00.00.28
.28 8 SU.14.05.00.5.00.00.00.5.05.14.14.00.28.5.00.09 1.18 1.18 I.66.42 1.70.47.52.28.47.24.19.19.42.28 1.37 3.02.28.47 10.99 10 3 1 55.42.47.33.33.09.05.05.33.57.19.61.14.19.28.42.00 4.48 4.48 2 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 17.54 0.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 1 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 3 SU.00.00.00.00.00.00.00.00.00.00.00.00.;0.00.00.00.00
.00 N.00.05.42 '.05.00.00.00.00.00.00.00.05.05.00.00.00.61
.61
' 1 55.00.00.05.00.00.00.00.09.05.00.00.00.00.00.00.00.19
.19 I E. 00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 5.00.80.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 1
m
a Cued 50 CIES STAT 13 October-De:eder 1997 33 ft. EE MED and EE DECT13 196-33 ft. DIFFERENTIAL TEFERATE STEILM CLEH5 ---
y((p............
........... EE DECT13 CLEH5 CLASS N N E [E E ESE SE SSE 5 52 2S V N W N TOTAL EU E Su I
$5 E E5 TOTAL EU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 1 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 9 SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 I.00.00.05.00.00.00.00.00.00.00.00.00.00.00.00.00.05
.05 2 55.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 4 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 ES.00.00.00.00.00.00.00.00.00.00.00.%.00.00.00.00.00
.00
.05 EU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 6 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 i SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 N.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 2 55.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 4 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 ES.00.00.00.00.00.00.00.00.00.W.00.00.00.00.00.00.00
.00
.00 TOT 4.40 3.42 6.015.215.M 5.53 5.315.54 4.M 5J5 7.46 4J310.1713.30 B.05 5.6100.001.651.04 2.0 39.93 38.38 8.86 7.45100.00 Wind Direction by 5tsility N N E EE E ESE $[ SSE 5 52 2B W N W N TOTAL -51A8ILM CLASSES-
.00.00.00.00.00.00.00.00.00.05.57.09.19.28.19.28 1.65 Extreely hstdle
.00.00.00.05.00.00.00.00.00.14.28.00.19.28.05.05 1.04 Noderately hstdle
.24.14.00.09.00.5.09.14.5.19.38.00 J5.28.14.14 2.69 Slightly hstele 1.891.13 3.0 2J8 2.41.991.5.951.181.18130 2.08 4J2 7.64 3.50 2.50 39.93 Ilatral lJ91.651.981J51.801.461.65 2.641.84 2.60 3.96 2.22 338 3J3 3.91.94 38.38 Slightly Stele
.H.20.24.29.29.U.97 1.12.82 1.25.48.29.M.68.39.39 8.86 Noderately Staole
.15.30.15.25.84 2.25.94.69.45.35.10.05.20.40.20.15 7.45 Extruely 5tsle Wind Direction by Wind Speed X W E EE E ESE SE SSE 5 52 2H V N W N TOTAL -W!E PEED CLASSES-
.00.00.00.05.00.00.00.00.00.00.05.00.00.00.00.00.09 (ALM
.921.20 J71.30 2.13 3.07 2.15 2J1 1.751.65.961.481.92 2.55 2.251J7 28.57 0.9 3.5 $
!.261.23 2.0 2.2 2.9 2.12 2.64 2.07 lJ4 3.58 5.14 !J3 6.32 6.98 4.95 3.02 52.95 3.6 - 7.5 $
1.23.H 2.03.H.61.33.52.66.80.52 1.32.47 1.89 3.U.5.66 17.54 1.6 - 12.5 $
.00. 5.47.05.00.00.00.09. 5.00.00.05.05.00.00.00.80
!!.6 - 18.5 $
.00.00.05.00.00.00.00.00.00.00.e.s.00.00.00.00.05 18.6 - 24.5 5
.00.00 '.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
> 24.5 $
a CzEd @D(lilES STATIM October-Decuber 1997 296 ft. VIE SPEED nd Wit DIREC110R 29643 ft. DiffEREXIIE TEfERATRE WEER Of OBSRVAil35 = 2163 RUES ARE PRENT 000PRI SPEED VIE DIRECilm RASSES --
STA81L11Y EASSES - ---- -
EASS I E ME EE E ESE SE SSE $ 19 SW WSW W N E N TOTAL EU E SU N SS E IS TOTAL EU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 W.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 C SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 A R.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 L $$.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 R NS.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
.00 EU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 1 SU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00
- R.23.09.18.09.14.09.09.09.09.09.09.05.18.18.09.09 1.90 1.90 3 SS.00.14.14.14.23.14.05.00. 5.09.05.09.05.00.05.00 1.25 1.25 E.05.5.00.05.09.05.00.00.05.05.00.05.00.00.00.00.42
.42 ES.5.09.09.00.05.00.00.00.5.00.00.00.05.00.00.00.37
.37 3.93 EU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 W.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 4 SU.14.05.00.00.00.00.00.00.00.00.00.00.05.09.14.14.60
.60 N.42.32.23.18.55.09.09.05.23.51.32.6.79.28 1.11.60 6.43 6.43 7 SS.14.18.23.09.28.28.14.32.23.18.09.23.00.05.18.28 2.91 2.9)
MS.09.05.09.14.18.05.05.00.09.00.05.05.05.00.00.09.97
.97 IS.00.05.05. 5.09.05.14.14.14.14.05.05.18.00.05.05 1.20 1.20 12.11 EU.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.5
.05.05 W.00.00.00.00.00.00.00.00.00.23.00.05.05.00.09.05.46
.46 8 SU.00.00.00.00.00.00.18.00.00.46.14.00.18.09.00.00 1.06 1.06 N.69.4.65 1.94 1.25.92.74.42.28.65.23.79 1.80 2.11 1.57 1.16 15.85 15.86 1 $$.37.46.65.46.18.60.65.28.28.55.37.32.46.60.74.51 7.6 7.49 2 E.09.09.28.00.42.00.05.46.23.42.18.14.05.18.23.51 3.33 3.33 ES.14.05.09.00.00.00.14.5.46.42.5.00.5.5.00.00 1.48 1.48 29.73 EU.00.00.00.00.00.00.00.00.00.00.00.00.00.5.09.00.14.14 1 E.00.00.00.00.00.00.00.00.00.32.00.00.00.18.05.09
.6
.6 3 SU.00.00.5.00.00.00.00.05.00.14.05.05.00.18.00.5
.55
.55 N.74.69 2.03.79.79.42.92.23.461.25.691.201.94 4.721.481.4819.0 19.83 1 $$.37.69.18.00.00.05.60 1.02 1.29 2.13 1.62.46 1.11 1.57 1.16.E !!.90 12.90 8 E.14.00.05.05.05.32.14.46.79.97.32.00.28.18.28.18 4.21 4.!!
ES.09.00.00.00.09.00.05.60.5.32.09.05.00.05.05.05 2.08 2.08 40.36
O
=
0>'
Cdd DE CITIES STAT 1R October-Detteer IN7 296 ft. WIE SPEG and W!E DIECTIR 296-33 ft. DIffEENTIAL TEFERATRE SPEED -- - - -
- ---- -- Wit DIECila CLASE5 --- ------- --
-- - -- STMll!U CLASES -
CLASS I E. E EE E ESE' SE S5E S SW WG W N N N TOTAL D E 2 1 55 E ES TOTAL U.00.00.00.00.00.00.00.00.00.00 '.00.00.00.00.00.00.00.00 1 4.00.00.00.00.00.00.00.00.00.00.00. 00.00.00.00.00.00
.00 9 2.00.00.00.00.00.00.00.00.00.05.00.00.00.09.00.00.14
.14 I.23.37 1.29.14.00.5.05.28.60.14.23.23.69 1.M.18.05 6.56 6.56
. ! 55.14.14.00.00.00.00.14.9.74 1.5 ~.88.09.05.14.14.00 4.M 4.5 4 5.00.00.00.00.00.00.14.H.09.10.05.00.05.05.00.00
.6 Ji ES.00.00.00.00.00.00.05.00.00.00.00.00.00.00.00.00.05
.05 12.39 9. %.00.05.00.00.00.00.00.00.00.00.00.00.00.00.00.05.05 G W.00.00.00.00.00.00.00.00.00.00.00.00.00.00 00.00.00
.00 i SU.00.00.00.00.00.00.00.00.00.09.00.00.00.00.00.00.09
.H I.00.14.42.00.00.00.00.23.14.05.00.05. 6.00.00.00 1.11 1.11
! $$.05 00.00.00 '.00.00.00.09.05.05.00.00.00.00.00.00.23
.23 4 E.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00
.00 ES.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.W
.00
.00 1.48 TDT 4.16 4.116.75 4.114.391.14 4.39 5.55 7.0311.33 5.55 4.58 8.1413.04 7.67 6.06100.00.231.112.45 51.0 29.D 9.57 5.18100.00 Wind Direction by Stellity X E E EE E ESE SE SSE 5 52 2S V N W W TOTAL -5TABILIU CLASSES.
.00.00.05.00.00.00.00.00.00.00.00.00.00.05.09.05. 23 Extruely hstele
.00.00.00.00.00.00.00.00.00.55.00.05.05,18.14.14 1.11 bderately hstile
.14.05.05.00.00.00.18.05.00.74.18.05.23. 4.14.18 2.45 Slightly hstele 2.312.084.813.142.731.621.901.291.802.21.572.965.509.484.443.3751.8 hatral 1.061.621.20.9.81.061.57 2.0 2.68 4.5 3.01 1.201.66 2.36 2.271.43 29.H Slightly Stele
.37.18.42.23.74.42.37 1.02 1.25 1.62.60.23.42.42.51.79 9.57 bderately Stdle
.28.18.23.05.23.05.37.79 1.29.88.18.09.28.09.H.H 5.18 Extruely Stele Wind Direction by Wind Speed N K E EE E ESE SE SSE 5 SW WG W W W N TOTAL 4!$ SPEED CLASSES-
.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00.00 '.00 CALM
.32.37.42.28.51.28.14.H.28.23.14.18.28.18.14.09 3.93 0.9 3.5 sph
.79.65.60. 4 1.11. 6.42.51.69.83.51.97 1.06.42 1.48 1.16 12.11 3.6 7.5 sph 1.29 1.06 1.66 2.40 1.5 1.53 1.76 1.20 1.25 2.73.97 1.29 2.59 3.24 2.64 2.27 29.73 7.6 - !!.5 aph 1.341.39 2.31.83.92.791.712.36 3.19 5.13 2.H 1.76 3.33 6.93 3.10 2.50 40.36 12.6 - 18.5 sph
.37.51 1,29.14.00.H.371.061.43 2.221.16.32.79 2.27.32.0512.39 18.6 24.5 sph
.05.14. 4.00.00.00.00.32.18.18.00.05.09.00.00.00 1,48
> 24.5 sph.