Forwards Safety Evaluation Approving Preliminary Design for safety-grade Anticipatory Reactor Trip on Loss of Feedwater & Turbine Trip.Requests Addl Info for Final Design Approval
ML20213D072
Person / Time
Site: Oconee, Arkansas Nuclear, Crystal River, Rancho Seco, 05000000
Issue date: 12/20/1979
From: Reid R
Office of Nuclear Reactor Regulation
To: Mattimoe J
SACRAMENTO MUNICIPAL UTILITY DISTRICT
Shared Package
ML20213D074 List:
References
TASK-2.K.2.10, TASK-TM TAC-45188, NUDOCS 8001110627
Download: ML20213D072 (3)


Text

t m.4 p rge -

h 4

o, UNITED STATES (f[

)

d( (

[

g',

j NUCLEAR REGULATORY COMMISSION hk E

WASHINGTON, D. C. 20555

(

0-h' g).

December 20, 1979 g

/

/

f p r),3d

  • SIk Docket No. 50-312-Mr. J. J. Mattimoe Assistant General Manager and i

Chief Engineer Sacramento Municipal Utility District 6201 S Street P. O. Box 15830 Sacramento, California 95813

Dear Mr. Mattimoe:

SUBJECT:

PRELIMINARY DESIGN APPROVAL FOR THE SAFETY-GRADE ANTICIPATORY REACTOR TRIP (ART) ON LOSS OF FEEDWATER AND TURBINE TRIP We have reviewed your submittals of May 21 and October 5,1979, in which you forwarded a preliminary design for upgrading the present control-grade ART for loss of feedwater and turbine trip to safety-grade. A copy of the staff safety evaluation (SE) approving your preliminary design is included as an enclosure to this letter.

i i

As sumarized in Attachment 1 of this evaluation, additional information:-

will1 need;to be: submitted prior' to the final:.' design approval.

Therefore, insure that this information is submitted for staff review in sufficient time to allow staff approval prior to system operation.

If you have any questions in this matter, please contact the NRR Operating Reactor Project Manager, Mr. Daniel Garner at (301) 492-7435.

4 Sincerely, y../.OfI..%}'<l.

y Robert W. Reid, Chief Operating Reactors Branch #4 Division of Operating Reactors

Enclosure:

i SE cc w/ enclosure:

See next page

~

9 q

b

Sacramer.to Municipal Utility District cc.w/ enclosure (s):

Christopher Elliscn, Esq.

David S. Kaplan, Secretary and Dian Grueufch, Esc General Counsel California Energy demission 6201 S Street 1111 Howe Avenue P. O. Box 15830 Sacramento, Califerr.ia 95825 Sacramento, California 95813 Ms. Eleanor Schwartz Sacramento County California State Cffice Board of Supervisors 600 Pennsylvania Avenue, S.E., Rm. 201 827.7th Street, Room 424 Washington, D.C.

20C33 Sacramento, California 95814 Docketing and Service Section Office of the Secretary Business and Municipal Department U. S. Nuclear Reg;1t.tcry Commission Sacramento City-County Library Washington, D.C.

20555 828 I Street Sacramento, California 95814 Director, Technical Assessnent Division Office of Radiation Programs Dr. Richard F. Cole (AW-459)

Atomic Safety and Licensing Board U. S. Environnental Protection Agency Panel Crystal Mall #2 U. S. Nuclear Rec;1atory Commission Arlington, Virginia 20463 Washington, D.C.

20555 U. S. Environmental Protection Agency Mr. Frederick J. Shon Atomic Safety anc Licensing Board A

SC INATOR S n Franc sco a ifornia 94111 h go 0,C Mr. Robert B. Borsum Elizabeth S. Bowers, Esq.

. Babcock & Wilcox Chairman, Atomic Safety and

!!uclear Power Generation Division Licensing Board Par.el

%ite a20, 7735 Old Georgetown Road U. S. Nuclear Regulatory Commission Lethesda, Maryland 20014 Washington, DC 20555 James S. Reed, Esq.

Thomas Baxter, Eso.

Michael H. Remy, Esq.

Shaw, Pittman, Potts & Trowbridge Reed, Samuel & Remy 1800 M Street, f!N 717 K Street, Suite 435 lashington, D. C.

20036 Sacramento, California 95814 Herbert H. Brown, Esq.

Mr. Michael R. Eaten Lawrence Coe Lanpher, Esq.

Energy Issues Cocrcir.ator Hill, Christopher and Phillips, P. C.

Sierra Club Legislative Office 1900 M St., NW 1107 9th St., Ro:- IC20 Washington, D. C.

20036 Sacramento, CA 95Ela h

' Sacrament'o Municipal Utility District

' ec w/ enclosure (s):

Atomic Safety and Licensing Board-Panel U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Atomic Safety and Licensing Appeal Board Panel U. S. Nuclear Regulatory Commission Washington, D.C.

20555 Mr. Richard D. Castro 2231 K Street Sacramento, California 95814 Mr. Gary Hursh, Esq.

520 Capital Mall Suite 700 Sacramento, California 95814 California Department of Health i

ATTN:

Chief. Environmental l

Radiation Control Unit Radiological Health Section 714 P Street, Room 498 Sacramento, California 95814 L

4 I

k

.Ik.

8 ~