1 IEl'ROIT EDISOti 0@! PAIN FERII - 2 NUCLEAR 10ER PIRE OPERATI!G LICENSE 10. NPF - 43 0

SD1I-ANtKAL RADIOCIVE EFFLUEIE RELEASE REEORT FOR ' HIE PERICD OF JULY 1,1986 'HIROUGH DECE2EER 31,1986

!FA855i!8#e884u 7gLS PDR s

TABLE OF COITTEETfS Introduction Regulatory Limits....................................................Page 1 Maxiraum Permissible Concentration....................................

2 Ave rage Ene rgy.......................................................

3 Measurements and Approxinations of Total Activity..................

3

(

Batch Releases.......................................................

7 AbnorDal Releases....................................................

7 LIST OF ElX2DSUPES 1.

Batch Release Data 2.

Gaseous Effluent Sur:r:ary 3.

Liquid Effluent Smraary 4.

Radiological Impact on Man Gaseous--Liquid Effluent 5.

Solid Radwaste Shigaents 6.

!!eteorological Data 7.

Changes to Process Control Program 8.

Inoperable Effluent Instrumentation 9.

Potential Dose Assessment

10. Changes to the Offsite Dose Calculation Manual (GXII)

FEPJII-2 SE!!IA! DUAL PADIOIDGICAL EFFLUDTP REIORP 1.0 Introduction Ebrmi-2 is designed and operated to strictly control the release of radioactive effluents to the erwiroment in accordance with the !bclear Pegulatory Commission (!K) regulations. This Semiannual Radioactive Effluent Report stmraarizes the quantities of radioactive material released from the plant. These releases are in the form of radioactive gases and liquid effluents.

Sunrnrized in this report are the projected cbses to menbers of the Public from radioactive effluents released frora the plant and the Begulatory Limits for these releases. Also provided are the quantities of radioactive material contained in solid waste packaged and shipped to offsite disposal sites.

In the reporting period, July through December 1986, the total effluent releases and resulting potential doses to the public were maintained As Im As Reasonably Achievable (ALAPA). A sumary of radioactive effluents released and potential cbses in comparison to IK limits are shown below:

I E Limits Fermi-2 Potential Dose - %

Gaseous Effluents IIoble Gases (Unrestricted Areas) 110 mrad gamraa / year 0.0 mrad

-0 120 mrad betgyear 0.0 raral

-0 Dose to an individual from I-131,133, tritium, and particulates 115 mrervyear 0.0 mrem

-0 Liquid Effluents ear Total Body 0.001135 mrsa 0.38 %

13 mreVy/ year Organ 110 mrea 0.001732 mrsa 0.17 %

(liver)

Detailed in this report, are the pertinent data in support of the above stmraation.

i Page 1 4

a 1.

Regulatory Limits A. r-mawma Effluents:

A.1 Dose rate due to radioactive materials released in gaseous affluents from the site to areas at and beyond the site boundary shall be limited to the following:

3

a. Noble gases - Less than or equal to 500 mrervyear to the total body

- Less than or equal to 3000 mravyear to the total body

b. Iodine-131, 133, Tritiura, and for all radionuclides in particulate form with half-lives greater than

-8 days

- Less than or equal to 1500 mravyear to any organ A.2 Air & se due to noble gases released in gaseous efflants, from each reactor unit, to areas at and beyond the site boundary shall be limited to the following:

i

a. Less than or equal to 5 mrads for gama radiation Iess than or equal to le mrads for beta radiation

- During any calendar quarter i

l

b. Less than or equal to le mrads for gama radiation Less than or equal to 20 mrads for beta ra31ation

- During any calendar yes.:

A.3 Dose to a menber of the public from Iodine-131, 133, Tritium, and all radionuclides in particulate form with half-lives greater than 8 days in gaseous effluents released, fran each Reactor unit, to areas at and beyond the site boundary shall be limited to the following:

a. Iess than or equal to 7.5 mrams to any organ

- During any calendar quarter

b. Less than or equal to 15 mrens to any organ

- Daring any calendar year

Page 2 B. Liquid Effluents:

B.1 Se concentration of radioactive material released in liquid affluents to unrestricted areas shall be limited to the concentrations specified in Title le of the Code of Federal Regulations Part 20 (Standards for Protection Against Radiation),

Appendix B, Table II, L'cn 2 for Radianuclides other than dissolved or entrained. /3 gases. Fordissolvedorentr_ay noble gases, the concent (tion shall be limited to 2 X 10

(.0002) microcuries/ml tt al activity.

B.2 The dose or cbse cemitment to a member of the public from radioactive materials in liquid effluents released, fra each reactor unit to unrestricted areas shall be limited:

a. Less than or equal to 1.5 mran to the total body i

Less than or equal to 5 mrera to any organ j

- During any calendar quarter

b. Less than or equal to 3 mrera to the total body Less than or equal to 10 mrea to any organ

- During any calendar year

2. Maxinum Permissible Concentration A. Liquids
1. The maximum permissible concentrations (MPC) for liquids are those listed in 10 CFR 20, Appendix B, Table II, Colutn 2, with the nost restrictive MPC being used in all cases. For dissolved and entrained gases the MPC of 2.OE -4 microcuries/ml is applied. This MPC is based on %e-13511PC in air (submersion Dose) converted to an equivalent concentration in water as discussed in the International Cam:nission on Radiological Prote:: tion (IGP) Publication 2.

B. Gaseous

1. he maxinum permissible dose rate for gaseous releases are defined in plant technical specifications.
a. Technical specification 3.11.2.1.b (Iodine - 131, 133, Tritium, and particulates with half-lives greater than 8-days.)

- Less than or equal to 1500 mravyr.

l 1 -

Page 3 i

i

~

b. Technical specification 3.11.2.1 (Dose rate at site boundary from gaseous effluents)

- Less than or equal to 599 mren/ year to total body.

- Less than or equal to 3999 mreig/ year to skin.

3.

Average Energy

%e release rate limits for fission and activation gases, in gaseous effluents, are dose rate based in accordance with plant technical specifications.

4.

Measuranents and Approximations of Total Activity A. Gaseous Effluents

1. Fission and Activation Gases
a. Sanples are obtained from each of the seven plant effluent radiation monitors, which monitor the six ventilation exhaust points. The fission and activation gases are quantified by

. ganna spectroscopy analysis those radionuclides that are quantified for dose calculations due to fission and activation gases are typical of the following:

Kr-87 Kr-88 Xe-133 i-Xe-133m Xe-135 Xe-138 Se reported total of fission and activation gases is the maxinum value of the sum all the monitored releases.

l Considering the uncertainties in radiation counting along with I

sanple volume, flow rate, and pressure measurenents; the total fission and activation gases estimates are expected to be in l

error by less than 7.4% low and 50.3% high.

l

2. Radioiodines
a. Sanples are obtained from each of the seven plant effluent radiation monitors, which monitor the six ventilation exhalst points. The radioiodines are entrained on a charcoal media.

l The radioiodines are then quantified by genna spectroscopy analysis. For each sanple, the duration of sanpling and continuous flow rate through the media are used in determining I

the concentration. In each case the flow rate of the ventilation system is known such that a rate of release can be i

4

b Page 4 determined. Se radioiodines that are quantified for cbse calculations are the following:

I-139 I-133 I-131 I-134 I-132 I-135 Se reported total of radioiodines.is the maximum value of the stun all the monitored releases.

3. Particulates
a. Samples are obtained from each of the seven plant effluent radiation monitors which monitor the six ventilation exhaust points. We particulates are entrained on a filter media, ne particulates are then quantified by gama spectroscopy analysis. For each sanple, the duration of sanpling and
q continuous flow rate through the filter are used in &termining the concentration. In each case the flow rate of the ventilation system is known such that a rate of release can be determined. Se particulates that are quantified for dose 3

calculations are typical of the following:

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Mo -99 Cs-134 Cs-137 Ce-141 Ce-144 (Other radionuclides with half-lives greater than 8 days)

A conposite of the filters obtain from each ventilation release point are analyzed monthly of gross alpha radioactivity, by proportional counting, and quarterly for Sr 89/90 activity by radiochemical separation and gas proportional counting.

If quantified, these totals are reported as total particulate activity.

Se reported total particulate is the maxinum value of the sun all the monitored releases.

Considering the uncertainties in radiation counting along with sanple volume, flow rate, and pressure measurenants, the total radioiodine and particulate estimates are expected to be in error by less than 22.9% low and 54.8% high.

Page 5

4. Trititrn
a. Sanples are obtained fran each of the seven plant effluent radiation monitors which monitor the six ventilation exhaust points. %e sanple is passed through a bottle containing water. While the sanple is being passed through the bottle the tritium is " washed" out to the collecting water. Portions of the collecting water a.e analyzed for tritium using liquid scintillation counting techniques. For each sanple, the I

duration of sampling and sanple flow rate is used to determine the concentration.

If quantified the reportal total tritium release is the maxinum value of the sum of the monitored releases.

Considering the uncertainties in radiation counting alorg with sanple volume, flow rate, and pressure measurenents, total Tritium estimates are expected to be in error by less than 12.3%

low and 51.2% high.

B. Liquid Effluents:

1. Fission and activation products
a. Prior to the release of a waste sample tank (s), representative samples are obtained. Fission and activation products are quantified by ganma spectroscopf analysis. The radionuclides quantified are included in the cbse calculations. Fission and activation products quantified are typical of the following:

Mn-54 Fe-59 Co-58 Co-60 Zn-65 Mo-99 Cs-134 Cs-137 Ce-141 Ce-144 (other radionuclides as quantified)

From each batch release a portion of the sanple is retained as a composite. A composite is defined as a quantity of sanple that is proportional to the amount of the total disdiarged, and representative of the arount discharged. The composite sanple is analyzed for Fe-55 and Sr-89/90 Both nethods involve radiochenical separation along with quantification by liquid scintillation and proportional counting respectively.

Page 6 he total radionuclides released in this report is the sum of all radionuclides in all batch releases.

Considering the uncertainties in radiation counting; along with flow rate and volume measurements, total fission and activation product estimates are expected to be in error by less than 14.3%.

2. Tritium
a. From each batch release, a portion of the sanple is retained for conpositing. A conposite is defined as a quantity of sanple that is proportional to the amount of the total dis &arged, and is representative of the amount dis &arged. The co::posite sample is analyzed for Tritium by liquid scintillation counting. Se total Tritium activity reported is the sum of the Tritium activities for all batch releases.

Considering the uncertainties in radiation counting; along with flow rate and volume measurements, total fission and activation product estinates are expected to be in error by less than 14.3%.

3. Dissolved and Entrained Gases
a. Dissolved and entrained gases are quantified by gamma spectroscopy for each batch release of dissolved and entrained noble gases is limited to 2.0E -4 microcuries/ml total activity. The following radiogases are typical of those considered when quantified:

Kr-85m Xe-131 Kr-85 Xe-133 Kr-88 Xe-137 Kr-89 Xe-138 he total report is the sta of all radiogases quantified for all batch sanple tanks releases.

Considering the uncertainties in ra31ation counting; along with flow rate and volume measurements, total dissolved and entrained gases estimates are expected to be in error by less than 15%.

i

Page 7

4. Gross Al@ a
a. From each batch release, a portion of the sanple is retained for conpositing. A conposite is defined as a quantity of sanple that is proportional to the amount of the total discharged; and is representative of the amount disdiarged. The conposite sanple is analyzed for gross alpha by gas proportional counting. h total gross al@a activity reported is the stra of the gross activities for all batch releases.

Considering the uncertainties in radiation counting; along with flow rate, volume and measurements, and conpositing measurements, total gross alpha estilantes are expected to be in error by less than 22.5%.

5. Batch Releases
a. A stramary of data for batch releases is provided in Enclosure 1.

Included are the ntmber of releases, total time period for batch releases, and the maxim.na, average, and mininun time period of release.

6. Abnormal Releases At 1930 hours0.0223 days <br />0.536 hours <br />0.00319 weeks <br />7.34365e-4 months <br /> on November 17, 1986, with the rea: tor in cold shutdown, a weld failed on the HPCI/RCIC test line penetration at the bottcra of the Condensate Storage Tank (CST). The weld failure was due to over pressurization of the test line, which caused deformation of an expansion bellows and related movement of the test line against the weld. 'Ihe failed weld resulted in leakage of approxinately 275,000 gallons of slightly contaninata3 water from the CST. The CST spill water soaked into the ground in the diked area surrounding the CST and flowed into underground cable ducts.

Approxinately 160,000 gallons of dilute contaminated water was recoveral from the cable ducts and returned to the Radwaste facility.

Spill water sanples indicatel ra3ioactivity concentrations of approxinately 2% (0.02) of the Maximum Permissible concentration (MPC) values specified in 10CFR20, Appendix B, Table II, Column 2, for radioactivity in eff1 tents to unrestricted areas. The detectable radioactivity consisted primarily of tritium (H-3) with trace quantities of Cobalt-58. In addition, sanples taken in the CSP diked area following the spill indicated trace levels of radioactivity in the soil, humimi um-mmmmums

Page 8 Using the methods of the Fermi 2 Offsite Dose Calculation Manual (GX21), a maxinum potential dose to a member of the public through fish and water consunption was calculated as 0.00002 milliran (2/100,999ths of a milliren). This is well below the value of 3 millirems per year which is given in the Fermi 2 Technical specifications as the limit for total body radiation exposure fran liquid radioactive affluents to a member of the public.

Licensee Event Report (LER) No. 86-45, describing this event was issued on January 12, 1987.

l l

I k

\\

\\

l I

t

j J

)

4 Etn osung i N I RELEASE DATA i

k f

F REPORT CATEGORY

BATCII RELEASE

SUMMARY

-RELEASE POINT 8 CIRCULATING WATER DECANT LINE TYPE CP RELEASE

BATCH LIQUID

' PERIOD START TIME

4344 : 00 HRS = 12 : 00 A!! JULY 1, 1986 PERIOD END TIME
8759:59 HRS = 11 : 59 PM 'DECEMB ER 31, 1986 LIQUID RELEASES NUMBER OF RELEASES 90 TOTAL TIME FOR ALL RELEASES :

43759;0 !!INUTES MAXIMUM TIME FOR A RELEASE 5 85.0 MINUTES AVERAGE TIME FOR A RELEASE 4 86.2 MINUTES MINIMUM TIME FOR A RELEASE 1 21.0 MINUTES

~ AVERAGE STREAM FLOT NA GPM 4

t O

l I

l 4

i l

4

,--n-

--...-.,,,n.,_,r,--,,-----.--.-,-_,,--.-

- _ - -.. ~..,..

____W t

j

  1. s b

a-4 s

\\

w P

4 DCIDSUPS 2 CASEQJS EFFLtENP SOf'1M O

==

w 1

f

REPORT CATEGORY SEMIANNUAL SUMMATION OF ALL RELEASES BY QUARTER TYPE OF ACTIVITY

ALL AIRBORNE EFFLUENTS REPORTING PERIOD
QUARTER # 3 AND QUARTER 4 4 UNIT
QUARTE.R 3 : QUARTER 4
HOUR 3
HOUPS TYPE OF EFFLUENT.
4345-6f 52 :6553-8760 A.

FISSION AND ACTIVATION PRODUCTS

CURIES
0.00E-01 : 0.00E-Cl :
1. '_IOTAL RELEASE
2. AVERAGE RELEASE RATE FOR PERIOD UCI/SEC
0.00E-01 : 0.00E-01 :

D. RADIOIODINES

1. TOTAL IODIllE-131
CURIES
0.00E-01 : 0.00E-01 :
2. AVERAGE RELEASE RATE FOR PERIOD
UCI/SEC
0.00E-01 : 0.00E-01 :

C. PARTICULATES

1. PARTICULATES(!! ALP-LIVES >8 DAYS)
CURIES
4.7 2E-0 8. : 2.21E-07 :

_2. AVERAGE RELEASE RATE FOR PERIOD

UCI/SEC
5.0 9E.-0 9 : 2.56 E-0 8 :

l

3. GROSS ALPilA RADIOACTIVITY
CURIES
4.7 2E-0 8 : 2.21E-07 f D.

TRITIUM

CURIES
0.00E-01 : 0.00E-01 :
1. '_IOTAL RELEASE l
2. AVERAGE RELEASE RATE FOR PERIOD
UCI/SEC
0.00E-01 : 0.00E-01 :

h I

1 a

l 1

l

~v

T REPORT CATEGORY

SEMIANNUAL AIRDORNE CONTINUUL S RELEASES TYPE OF ACTIVITY
FISSION GASES, IODINES, AND PARTICULATES REPORTING PERIOD
QUARTER # 3 AND QUARTER f 4 GROUND RELEASES 1

UNIT

QUARTER 3 : QUARTER 4 :

HOURS

HOURS NUCLIDE
4345-6552 36553-8760 :

PARTICULATES CONTINUED CS-137 CURIES

0.00E-01 : 0.00E-01 :

CS-138 CURIES

0.00E-01 : 0.00E-01 :

B A-13 9 CURIES

0.0 0 E-01 : 0.00E-01;:

BA-140 CURIES

0.00 E-01 : 0.00E-01 :

BA-141 CURIES

0.00E-01 : 0.00E-01 :

BA-142 CURIES

0.00E-01 : 0.00E-01 :

LA-140 CURIES

0.00E-01 : 0.00E-01 :

LA-142 CURIES

0.00E-01 : 0.00E-01 :

CE-141 CURIES

0.00E-01 : 0.00E-01 :

CE-143 CURIES

0.00E-01 : 0.00E-01 :

CE-144 CURIES

0.00E-01 : 0.00E-01 :

PR-143 CURIES

0.00E-01 : 0.00E-01 :

PR-144 CURIES

0.00E-01 : 0.00E-01 :

ND-147 CURIES

0.00E-01 : 0.00E-01 :

W-187 CURIES

0.00E-01 : 0.00E-01 :

NP-23 9 CURIES

0.00E-01 : 0.00E-01 :

SR-90 CURIES

0.00E-01 : 0.00E-01 :

G ALPHA CURIES

4.7 2E-0 8 : 2.21E-07 :

l i W TAL POR PERIOD CU RIES

4.7 2E-0 8 : 2.21E-07 :

l i

t 4

A REPORT CATEGORY

SEMIANNUAL AIRBORNE CONTINUOUS RELEASES TYPE OF ACTIVITY
FISSION GASES, IODINES, AND PARTICULATES REPORTING PERIOD
QUARTER # 3 AND QUARTER # 4 GROUND RELEASES

_ - - - - - - -.... - - - - - - - - - - - - - - - - - - - - ~ ~ - - - - - - - - - - - - - - - - - - - - - -

UNIT

QUARTER 3 : QUARTER 4 :
HOURS
HOURS NUCLIDE
4345-6552 :6553-8760 :

- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ~ - - - - - - - - - - - - - - - - - - - - - - -

PARTICULATES CONTINUED


~-----------------------

Y-92 CURIES

0.00E-01 : 0.00E-01 :

Y-93 CURIES

0.00E-01 : 0.00E-01 :

2R-93

- CURIES
0.00E-01 : 0.00E-01 :

ZR-97 CURIES

0.00E-01 : 0.00E-01 :

NB-95 CURIES

0.00E-01 : 0.00E-01 :

MO-99 CURIES

0.00E-01 : 0.00E-01 :

TC-99M CURIES

0.00E-01 : 0.00 E-01 :

TC-101 CURIES

0.00E-01 : 0.00E-01 :

RU-103 CURIES

0.00E-01 : 0.00E-01 :

RU-105 CURIES

0.00E-01 : 0.00E-01 :

i RU-106 CURIES

0.00E-01 : 0.00E-01 :

)

AG-110n CURIES

0.00E-01 : 0.00E-01 :

TE-125H CURIES

0.00E-01 : 0.00E-01 :

TE-127M CURIES

0.00 E-01 : 0.00 E-01 :

TE-127 CURIES

0.00E-01 : 0.00E-01 :

TE-129M CURIES

0.00E-01 : 0.00E-01 :

I

TE-129 CURIES
0.00E-01 : 0.00E-01 :

1 TE-131M CURIES

0.00E-01 : 0.00E-01 :

TE-131 CURIES

0.00E-01 : 0.00E-01 :

TE-132 CURIES

0.00E-01 : 0.00E-01 :

I-130 CURIES

0.00E-01 : 0.00E-01 :

I-131 CURIES

0.00E-01 : 0.00E-01 :

I-132 CURIES

0.00E-01 : 0.00E-01 :

! I-133 CURIES

0.00E-01 : 0.00E-01 :

l-I-134 CURIES

0.00E-01 : 0.00E-01 :

l I-135 CURIES : 0.00E-01 : 0.00E-01 :

CS-134 CURIES : 0.00E-01 : 0.00E-01 :

CS-136 CURIES : 0.00E-01 : 0.00E-01 :

)

e i

_ _ ~ _. _

r i

REPORT CATEGORY SEMIANNUAL AIRBORNE CONTINUOUS RELEASES TYPE OF ACTIVITY

FISSION GASES, IODINES, AND PARTICULATES REPORTING PERIOD
QUARTER # 3 AND QUARTER # 4 t

GROUND RELEA

____.-___..-_________________________________--____SES l

UNIT

QUARTER 3 : QUARTER 4 :

HOURS

HOURS NUCLIDE 4345-6552 :6553-8760 :

PARTICULATES H-3 CURIES

0.00E-01 : 0.00E-01 :

C-14 CURIES

0.00E-01 : 0.00E-01 :

NA-24 CURIES

0.00E-01 : 0.00E-01 :

P-3 2 CURIES

0.00E-01 : 0.00E-01 :

CR-51 CURIES

0.00 E-01 : 0.00E-01 :

l MN-54 CURIES

0.00E-01 : 0.00E-01 :

MN-56 CURIES

0.00E-01 s 0.00E-01 :

FE-55 CURIES

0.00E-01 : 0.00E-01 :

FE-59 CURIES

0.00E-01 : 0.0 0 E-01 :

CO-58 CURIES

0.00E-01 : 0.00E-01 :

CO-60 CURIES

0.00E-01 : 0.00E-01 :

NI-63 CURIES

0.00E-01 : 0.00E-01 :

NI-65 CURIES

0.00E-01 : 0.00E-01 :

CU-f> 4 CURIES

0.00E-01 : 0.00E-01 :

IN-65 CURIES

0.00E-01 : 0.00E-01 :

Z N-6 9 CURIES

0.00 E-01 : 0.00E-01 :

BR-83 CURIES

0. 0 0 E-01 :
0. 00 E-01 :

BR-84 CURIES

0.00E-01 : 0.00 E-01 :

BR-85 CURIES

0.00E-01 : 0.00E-01 :

RB-86 CURIES

0.00E-01 : 0.00E-01 :

RB-88 CURIES

0.00E-01 : 0.00E-01 :

RB-89 CURIES

0.00E-01 : 0.00E-01 :

SR-89 CURIES

0.00E-01 : 0.00E-01 :

SR-91 CURIES

0.00E-01 :
0. 0 0 E-01 :

SR-92 CURIES

0.00E-01 : 0.00E-01 :

Y-90 CURIES

0.00E-01 : 0.00E-01 :

Y-91M CURIES

0.00E-01 : 0.00E-01 :

Y-91 a

CURIES

0.0 0 E-01 : 0

..._-_.-_...--_.-______________---__-_._______.-_.00E-01:

' EB

REPORT CATEGORY 8 SEMIANNUAL AIRBORNE CONTINUOUS RELEASES i

TYPE OF ACTIVITY

FISSION GASES, IODIN ES, AND PARTICULATES REPORTING PERIOD
QUARTER 0 3 AND QUARTER 9 4 GROUND RELEASES UNIT QUARTER 3 : QUARTER 4 :

HOURS

HOURS NUCLIDE
4345-6552 :6553-8760 :

FISSION GASES l KR.83M CURIES

0.00E-01 : 0.00E-01 :

f KR-85 H CURIES

0.00E-01 : 0.00E-01 :

KR-85 CURIES

0.00E-01 : 0.00E-01 :

KR-87 CURIES

0.00E-01 : 0.00E-01 :

KR-88 CURIES

0.00E-01 : 0.00E-01 :

KR-89 CURIES

0.00E-01 : 0.00E-01 :

KR-90 CURIES

0.00E-01 : 0.00 E-01 :

XE-131M CURIES

0.00E-01 : 0.00E-01 :

XE-133M CURIES

0.00E-01 : 0.00E-01 :

l XE-133 CURIES

0.00E-01 : 0.00E-01 :

l XE-135M CURIES

0.00E-01 : 0.00E-01 :

' XE-135 CURIES

0.00E-01 : 0.00E-01 :

XE-137 CURIES

0.00E-01 : 0.00 E-01 :

XE-13 8 CURIES

0.00E-01 : 0.00E-01 :

l-AR-41 CURIES

0.00E-01 : 0.00E-01 :

TOTAL FOR PERIOD CURIES

0.00E-01 : 0.00E-01 :

I IODINES I-130 CURIES

0.00E-01 : 0.005-01 :

I.131 CURIES

0.00E-01 : 0.00E-01 :

I-132 CURIES

0.00E-01 : 0.00E-01 :

I-133 CURIES

0.00E-01 : 0.00E-01 :

I-134 CURIES

0.00E-01 : 0.00E-01 :

I-135 CURIES

0.00E-01 : 0.00E-01 :

l TOTAL POR PERIOD CURIES

0.00E-01 : 0.00E-01 :

9 l

l m

--,---.m-c 7

7__

E!CIOSURE 3 JJOUID EFFLUEITP SIMWE

.,m.....

..w-

SEMIANNUAL SUMMATION OF ALL RELEASES DY QUARTER REPORT CATEGORY TYPE OF ACTIVITY

ALL LIQUID EFFLUENTS QUARTER # 3 AND QUARTER # 4 REPORTING PERIOD

_-------------------_-------------_ UNIT QUARTER 3 : QUARTER 4 r HOURS

HOURS 34345-6552 :6553-8760 I

TYPE OF EFFLUENT L

i p

A. FISSION AND ACTIVATION ' PRODUCTS

1. TOTAL RELEASE (NOT INCLUDING TRITIUM, GASES, ALPHA)
CURIES 5
1.9 8E-04 : 2.86 E-03 :

. 2. AVERAGE DILUTED CONCENTRATION UCI/ML 4.31E-10 : 5.24E-09 :

DURING PERIOD B. TRITIUM

)


_-_----------------_-_-_---RIES

CU
7.6 3 E-0 2 : 1.95 E-01 :

t

1. TOTAL RELEASE

(

2. AVERAGE DILUTED CONCENTRATION
UCI/ML
1.66 E-07 : 4.0 8E-07.1 DURING PERIOD C. DISSOLVED AND ENTRAINED GASES j
CURIES
0.00E-01 : 3.00E-05

)

1. TOTAL RELEASE i
2. AVERAGE DILUTED CONCENTRATION
UCI/ML
0.09 E-01 : 7.18E-ll :

DURING PERIOD 1

i 1

I D. GROSS ALPHA RADIOACTIVITY


__--_----_--__-_ ---------_-----_----_-------_-~~_---__.

CURIES
0.00E-01 : 0.00E-01 :
1. TOTAL RELEASE r

n

2.4]E6 __: 2.29E6 E. WASTE VOL RELEASED (PRE-DILUTION) : LITERS;-

-_---_--------_--_---_-_-_-----_-----_-ERS~- ----_-_------------- 7 E 8+---

q

LIT

') 't 9.08E8

-8.9 ig; l

F. VOLUME OF DILUTION WATER USED

,e G.

TOTAL VO MfE DILUTION DISCHARG_ED1_ _ __: LITERS

9.20E9
9.39Es

}

_ _.. _ _ _ _,... _ _ - _ _ _ _ _ _,. -. _ _, _, _. _., = _ _ _,.. - _,, _ _ _. _, _ _ _ _ _. _., _

,.---.-_-m.--

,..c

REPORT CATEGORY

SEMIANNUAL LIQUID BATCH RELEASES
TOTALS FOR EACH NUCLIDE RELEASED.

TYPE OF ACTIVITY

ALL RADIONUCLIDES REPORTING PERIOD
QUARTER 9 3 AND QUARTER 6 4 BATCH RELEASES UNIT
QUARTER 3 QUARTER 4 :

HOURS

HOURS 34345-6552 :6553-8760 :

NUCLIDE ALL NUCLIDES H-3 CURIES

7.63E-02 : 1.95E-01 :6 C-14 CURIES
0.00E-01 : 0.00E-01 :

NA-24 CURIES

1.50E-05 : 0.00E-01 0 P-32 CURIES
0.00E-01 : 0.00E-01 :

CR-51 CURIES

7.14E-05 : 0.00E-01 :

MN-54 CURIES

0.00E-01 : 5.86 E-06 :

MN-56 CURIES

0.00E-01 : 0.00E-01 :

FE-55 CURIES

1.0 8E-04 : 0.00E-01 :

FE-59 CURIES

0.00E-01 : 0.00E-01 :

CO-5 8 CURIES

0.00E-01 : 5.18E-04 :

CO-6 0 CU RIES

0.00E-01 : 1.05E-03 :

NI-6 3 CURIES

0.00E-01 : 0.00E-01 :

NI-6 5 CURIES

0.00E-01 : 0.00E-01 :

CU-6 4 CURIES

0.00E-01 : 0.00E-01 :

EN-65 CURIES

0.00E-01 : 0.00E-01 :

EN-6 9 CURIES

0.0 0 E-01 : 0.00E-01 :

BR-83 CURIES

0.00E-01 : 0.00E-01 :

BR-84 CU RIES

0.00E-01 : 0.00E-01 :

BR-85 CURIES

0.00E-01 : 0.00 E-01 :

RB-86 CURIES

0.00E-01 : 0.00E-01 :

RB-88 CURIES

0.00E-01 : 0.00E-01 :

RB-89 CURIES

0.00E-01 : 0.00E-01 :

SR-89 CURIES

0.00E-01 : 0.00E-01 :

CURIES ' : 0.00E-01 : 0.00E-01 :

SR-91 SR-92 CURIES

0.00E-01 : 0.00E-01 :

Y-90 CURIES

0.00E-01 : 0.00E-01 :

Y-91M CURIES

0.00E-01 : 0.00E-01 :

Y-91 CURIES

0.00 E-01 : 0.00E-01 :

..--------- -_. -___=-_====_====_===___--___ __---__ -__-_

f v.7 4,-ev u=-

+ =

REPORT CATEGORY 8 SEMIANNUAL LIQUID BATCH RELEASES

TOTALS FOR EACH NUCLIDE RELEASED.

TYPE OF ACTIVITY

ALL RADIONUCLIDES REPORTING PERIOD
QUARTER # 3 AND QUARTER # 4 BATCH RELEASES UNIT QUARTER 3 : QUARTER 4 :

nHOURS HOURS NUCLIDE

4345-6552 :6553-8760 :

l _ _ - _ _ _ _ _ - _ _ _ - _ _ _ _. _ _ _ - _ - _ _ _ - _ _ _ _. _ _ _ _ -

ALL NUCLIDES CONTINUED Y-92 CURIES

0.0 0 E-01 : 0.00 E-01 :

Y-93 CURIES

0.00E-01 : 0.00E-01 :

ZR-95 CURIES

0.00E-01 : 0.00E-01 :

ER-97 CURIES

0.0 0 E-01 : 0.00 E-01 :

NB-95 CURIES

0.00E-01 : 0.00E-01 :

MO-99 CURIES

0.0 0 E-01 : 0.00E-01 :

TC-99M CURIES

3.94 E-06 : 0.00E-01 :

TC-101 CURIES

0.0 0 E-01 : 0.00E-01 :

1 RU-103 CURIES

0.0 0 E-01 : 0.0 0 E-01 :

RU-105 CURIES

0.0 0 E-01 : 0.00E-01 :

RU-106 CURIES

0.00 E-01 : 0.00E-01 :

AG-110M CURIES

0.0 0 E-01 : 0.00E-01 :

TE-125M CURIES

0.00E-01 : 0.0 0 E-01 :

TE-127M CURIES

0. 00 E-01 : 0.0 0 E-01 :

TE-127 CURIES

0.00E-01 : 0.00E-01 :

TE-129!1 CURIES

0.00E-01 : 0.00E-01 :

TE-129 CURIES

0.0 0 E-01 : 0.00E-01 :

TE-13111 iCU RIES

0.00 E-01 : 0.00E-01 :

TE-131-CURIES

0.00 E-01 : 0.00E-01 :

TE-132 CURIES

0.0 0 E-01 : 0.00E-01 :

I-130 CURIES

0.00 E-01 : 0.00E-01 :

I-131 CURIES

0.00 E-01 : 0.00E-01 :

I-132 CURIES

0.00E-01 : 0.00E-01 :

I-133 CURIES

0.00E-01 : 0.00E-01 :

I-134 CURIES

0.00E-01 : 0.00E-01 :

I-135 CURIES

0.00E-01 : 0.00E-01 :

CS-134 CURIES

0.0 0 E-01 : 0.00E-01 :

CS-136 CURIES

0.00E-01 : 0.0 0 E-01. :

i l

- ' ~ ~

' REPORT CATEGORY

SEMIANNUAL LIQUID BATCH RELEASES
TOTALS FOR - EACH NUCLIDE RELEASED.

TYPE OF ACTIVITY

ALL RADIONUCLIDES REPORTING PERIOD-
QUARTER 9 3 AND QUARTER # 4 4

..-- --wwaw--aaaaaaaaas BATCH RELEASES UNIT

QUARTER 3 : QUARTER 4 :
BOURS
HOURS NUCLIDE
4345-6552 36553-8760 :

l ALL NUCLIDES CONTINUED CS-137 CURIES 0.00 E-01 : 1.2 8E-03 :

CS-13 8 CURIES

0.00E-01 : 0.0 0 E-01 :

BA-139 CURIES

0.00E-01 : 0.00E-01 :

BA-140 CURIES

0.00E-01 : 0.00E-01 :

BA-141 CURIES

0. 00 E-01 : 0.00E-01 :

BA-142 CURIES

0.00E-01 : 0.0 0 E-01 :

LA-140 CURIES

0.00E-01 : 0. 0 0 E-01 :

LA-142 CURIES

0.00E-01 : 0.00E-01 :

CE-141 CURIES

0.00E-01 : 0.00E-01 :

CE-143 CURIES

0.00E-01 : 0.00E-01 :

CE-144 CURIES

0.00E-01 : 0.00E-01 :
PR-143 CURIES
0.00E-01 : 0.00E-01 :

PR-144 CURIES

0.00E-01 : 0.00E-01 :

ND-147 CU RIES

0.00E-01 :
0. 0 0 E-01 :

W-187 CURIES

0.00E-01 : 0.00E-01 :

NP-23 9 CURIES

0.00E-01 : 0.00E-01 :

KR-83M CURIES

0.0 0 E-01 : 0.00E-01 :

- KR-85M CURIES

0.0 0 E-01 : 0.00E-01 :

KR-85 CURIES

= 0.0 0 E-01 : 0.00E-01 :

KR-87 CURIES

0.0 0 E-01 : 0.00E-01 :

o KR-88 CU RIES

= 0.00 E-01 : 0.00E-01 :

KR-89 CURIES

0.0 0 E-01 : 0.00 E-01 :

KR-90 CURIES

= 0.00E-01 : 0.00E-01 :

XE-131M CURIES

0.00E-01 : 0.00E-01 :

XE-133M CURIES

0.00E-01 : 0.00E-01 :

XE-133 CURIES

0.00E-01 : 3.00E-05 :

XE-135M CURIES

0.00E-01 : 0.00E-01 :

XE-135 CURIES

0.00E-01 : 0.0 0 E-01 :

t - -

REPORT CATEGORY

SEMIANNUE LIQUID i BATCH RELEASES TOTES FOR EACH NUCLIDE RELEASED.

TYPE OF ACTIVITY

ALL RADIONUCLIDES REPORTING PERIOD
QUARTER 4 3 AND QUARTER 4 4 BATCH RELEASES UNIT
QUARTER 3 : QUARTER 4 :

HOURS

HOURS NUCLIDE
4345-6552 :6553-8760 :

EL NUCLIDES CONTINUED XE-137 CURIES 0.00E-01 : 0.00E-01 :

XE-138 CURIES 0.00E-01 : 0.00E-01 :

AR-41 CURIES 0.00E-01 : 0.00E-01 :

SR-90 CURIES 0.00E-01 : 0.00E-01 :

G EPH A CURIES 0.00E-01 : 0.00E-01 :

OTHER CURIES 0.00E-01 : 0.00E-01 :

TOTE FOR PERIOD CURIES

7.6 5 E-0 2 : 1.97E-01 :

e 1

l l

q 9-,.,,..,9,,

,--.g

,,pg,,w,.,---v-w--w,.w,,,w-ww.,

,m--,-r,-.

-.-----+.rw-ww

b f

EZEIDSURS 4 RADIOLOGICAL IlIPACP Oli 11A!1 GASEOUS-LIQUID EFFLtE!7PS 9

RADIOLOGICAL IMPACT ON MAN

__ __ ___ ___ _ _ _ _ _ _ ___ __ __ _ _ _ _ _ _ _ _ _tason _Unuwf_ __ _ _ __ _ _ _ _ _ __ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

DETROIT EDISON COMPANY FERMI 2 1987: 1:23: 9:.5:28 GASEOUS RADIOACTIVE WASTE DATA FILE

- I CUPRILATIVE DOSE DATA

- 00 UNIT 2 ** QUARTER 1

OF 1986 **

DOSE FROM RADIOIODINES, PARTICULATES, AND TRITIUM AT CONTROLLING LOCATION:

TOTAL DOSE (MREM) FOR BONE 0.0000E201_

TOTAL DOSE (MREM) FOR LIVER 0.0000E-01 TOTE DOSE (MREM) FOR TOTE BODY 0.0000E-01 TOTE DOSE (MREM) FOR THYROID 0.0000E-01 TOTE DOSE (MREM) FOR KIDNEY 0.0000E-01 TOTAL DOSE (MREM) FOR LUNG

; 0.0000E-01 TOTAL DOSE (MREM) FOR GI-LLI

'O.0000E-01 NOBLE GAS DOSE AT SITE BOUNDARY:

TOTAL BODY DOSE TOTAL (MREM) 0.0000E-01 SKIN DOSE TOTE (MREM) 0.0000E-01 NOBLE GAS AIRDOSE AT SITE BOUNDARY:

TOTAL GAMMA AIRDOSE (MRAD) 0.0000E-01 TOTAL BETA AIRDOSE (MRAD) 0.0000E-01 00 UNIT 2 ** QUARTER 2

OF 1986 **

DOSE FROM RADIOIODINES, PARTICULATES, AND TRITIUM AT CONTROLLING LOCATION:

TOTAL DOSE (MREM) FOR BONE 0.0000E-01 TOTAL DOSE (MREM) FOR LIVER 0.0000E-01 TOTAL DOSE (MREM) FOR TOTAL BODY 0.0000E-01 TOTAL DOSE (MREM) FOR THYROID 0.0000E-01 TOTAL' DOSE (MREM) FOR KIDNEY 0.0000E-03 TOTAL DOSE (MREM) FOR LUNG 0.0000E-01 TOTAL DOSE (MREM) FOR GI-LLI 0.0000E-01 NOBLE GAS DOSE AT SITE BOUNDARY:

TOTAL BODY DOSE TOTAL (MREM) 0.0000E-01 SKIN DOSE TOTAL (MREM) 0.0000E-01 NOBLE GAS AIRDOSE AT SITE BOUNDARY:

TOTAL GAMMA AIRDOSE (MRAD) 0.0000E-01 TOTAL BETA AIRDOSE (MRAD) 0.0000E-01 00 UNIT 2 ** QUARTER 3

OF 1986 **

DOSE FROM RADIOIODINES, PARTICULATES, AND TRITIUM AT CONTROLLING LOCATION:

l TOTAL DOSE (MREM) FOR BONE 0.0000E-01 f

TOTAL DOSE (MREM) FOR LIVER 0.0000E-01 TOTAL DOSE (MREM) FOR TOTAL BODY 0.0000E-01 TOTE DOSE (MREM) FOR THYROID 0.0000E-01 TOTAL DOSE (MREM) POR KIDNEY 0.0000E-01 TOTAL DOSE (MREM) FOR LUNG 0.0000E-01 TOTE DOSE (MREM) FOR GI-LLI 0.0000E-01 NOBLE GAS DOSE AT SITE BOUNDARY:

TOTAL BODY DOSE TOTAL (MREM) 0.0000E-01 SKIN DOSE TOTAL (MREM) 0.0000E-01 NOBLE GAS AIRDOSE AT SITE BOUNDARY:

TOTAL GAMMA AIRDOSE (MRAD) 0.0000 E-01 TOTAL BETA AIRDOSE (hRAD) 0.0000 E-01 l

. -. - _, - - -. - - -, -, - - - - -... -,, - ~ - - -. -, -, _.,, _

.,._,...--._-----,--,.c.

00 UNIT 2 00 QUARTER 4

OF 1986 00 DOSE FROM RADIOIODINES, PARTICULATES, AND TRITIUM AT CONTROLLING LOCATION:

TOTE DOSE ' (MREM) FOR BONE 0.0000E-01 TOTE DOSE (MREM) FOR LIVER 0.0000E-01 TOTAL DOSE (MREM) FOR TOTAL BODY 0.0000E-01 TOTE DOSE (MREM) FOR THYROID 0.0000E-01 TOTE DOSE (MREM) FOR KIDNEY 0.0000E-01 TOTAL DOSE (MREM) FOR LUNG 0.0000E-01

- TOTE DOSE (MREM) FOR GI-LLI 0.0000E-01 NCBLE GAS DOSE AT SITE BOUNDARY:

TOTE BODY DOSE TOTAL (MREM) 0.0000E-01 SKIN DOSE TOTE (MREM) 0.0000E-01 NOBLE GAS AIRDOSE AT SITE BOUNDARY:

TOTAL GAMMA AIRDOSE (MRAD) 0.0000E-01 TOTAL BETA AIRDOSE (MRAD) 0.0000E-01 00 UNIT 2 ** TOTALS FOR 1986 **

DOSE FROM RADIOIODINES, PARTICULATES, AND TRITIUM AT CONTROLLING LOCATION:

TOTE DOSE (MREM) FOR BONE 0.0000E-01 TOTAL DOSE (MREM) FOR LIVER 0.0000E-01 TOTE DOSE (MREM) FOR TOTAL BODY 0.0000E-01 TOTE DOSE (MREM) FOR THYROID 0.0000E-01 TOTAL DOSE (MREM) FOR KIDNEY 0.0000E-01 TOTE DOSE (MREM) FOR LUNG 0.0000E-01 TOTAL DOSE (MREM) FOR GI-LLI 0.0000E-01 NOBLE GAS DOSE AT SITE BOUNDARY:

- TOTE BODY DOSE TOTAL (MREM) 0.0000E-01 SKIN DOSE TOTAL (MREM) 0.0000E-01 NOBLE GAS AIRDOSE AT SITE BOUNDARY:

TOTAL GAMMA-AIRDOSE (MRAD) 0.0000E-01 TOTE BETA AIRDOSE (MRAD) 0.0000E-01 eeo

= -

3 i

4 o-,---

,,,,-~,.%..ew


.--,--.---w.

,---..---e..w,.,

DETROIT EDISON COMPANY FERMI 2 1987_: 1:23: 8:40: 3 LIQUID RADIOACTIVE WASTE DATA FILE CU E LATIVE DOSE DATA 00 UNIT 2 ** QUARTER 1

OF 1986 **

TOTAL DOSE (MREM) FOR BONE 0.0000E-01 TOTE DOSE (MREM) POR LIVER 0.0000E-01 TOTE DOSE (MREM) POR TOTAL BODY 0.0000E-01 TOTE DOSE (MREM) FOR THYROID 0.0000E-01

~

TOTAL DOSE (MREM) FOR KIDNEY 0.0000E-01 TOTAL DOSE (MREM) FOR LUNG 0.0000E-01 TOTAL DOSE (MREM) FOR GI-LLI 0.0000E-01 00 UNIT 2 ** QUARTER 2

OF 1986 **

TOTAL DOSE (MREM) FOR BONE 2.1552E-05' TOTAL DOSE (MREM) FOR LIVER 1.5242E-05 TOTE DOSE (MREM) FOR TOTE BODY 3.8234E-06 TOTAL DOSE (MREM) FOR THYROID 3.516 0E-07 TOTAL DOSE (MREM) FOR KIDNEY 3.516 0E-07 TOTE DOSE (MREM) FOR LUNG 8.6 5 88E-06 TOTE DOSE (MREM) FOR GI-LLI 8.8940 E-06

    • UNIT 2 ** QUARTER 3

OF 1986 **

TOTE DOSE (MREM) FOR BONE 2.8598E-06 TOTAL DOSE (MREM) FOR LIVER 2.45 90 E-06 TOTE DOSE (MREM) FOR TOTAL BODY 1.0135E-06 TOTAL DOSE (MREM) FOR THYROID 5.7 23 9E-07 TOTAL DOSE (MREM) FOR KIDNEY 5.7157 E-07 TOTAL DOSE (MREM) FOR LUNG 1.6 273 E-06 TOTAL. DOSE (MREM) FOR GI-LLI 2.2180 E-06 00 UNIT 2 ** QUARTER 4

OF 1986 **

TOTAL DOSE (MREM) FOR BONE 1.2642E-02 TOTAL DOSE (MREM) FOR LIVER 1.7 299E-02 TOTAL DOSE (MREM) FOR TOTAL BODY 1.1345E-02 TOTAL DOSE (MREM) FOR THYROID 1.16 43 E-06 TOTE DOSE (MREM) FOR KIDNEY 5.8702E-03 TOTAL DOSE (MREM) FOR LUNG 1.9522E-03 TOTAL DOSE (MREM) FOR GI-LLI 4.9444E-04 00 UNIT 2 ** TOTES FOR 1986 **

TOTAL DOSE (MREM) FOR BONE 1.2666 E-0 2 TOTAL DOSE (MREM) FOR LIVER 1.7317 E-0 2 TOTAL DOSE (MREM) FOR TOTAL BODY 1.1350E-02' TOTAL DOSE (MREM) FOR THYROID 2.0 883 E-06 TOTAL DOSE (MREM) FOR KIDNEY 5.8712E-03 TOTAL DOSE (MREM) FOR LUNG 1.96 25 E-03 TOTAL DOSE (MREM) FOR GI-LLI 5.0555E-04 I

i*.

\\

l l

E!CIOSURS 5 Sa,ID PADETASI'E SHIPIE7PS

{

l l

79.000.50 Rev. 1 I

WORKSHEET A-2 EXAMPLE SOLID WASTES

SUMMARY

TABLE TABLE 'D1.1 SOLID WASTE AND IRRADIATED FUEL SHIPMEMS ~

A. SOLID WASTE SHIPPED OFFSITE FOR BURIAL OR DISPOSAL (Not irradiated fuel)

Unit 6-Month Est. Total 1.

Type of Waste NOTE: Waste Period Error, I

.-s, hipped as Class A -

NOT 3

ho. 0#0 E a.

Spent resins, filter sludges, m

evaporator bottons, etc.

Ci

s. s # 7 E /

3

,2,t. D 3 E NOTI b.

Dry compressible wsste, m

contaminated equip, etc.

Ci J.145 E -2.

AVAILABLE 3

E c.

Irradiated components, a

control rods, etc.

Ci E

3 E

d.

Other (describe) m Ci E

2.

Estimate of major nucitGe composition (by type of waste)

O a.

$2e ATk.<LucsY

\\

1 E

1 E

l 1

E b.

sg ATTAc.Juoff

  • 2.

1 E

1 E

1 E

1 E

c.

Ahwr 1

E 1

E 1

E d.

Akwd 1

E 1

E l

l 3.

Solid Waste Disposition Number of Shipments Mode of Transportation Destination OWHos;/OtebOL(ff 6Wshoct.L.,LC.

J9 B. IRRADIATED FUEL SHIPMEES (Disposition)

Number of Shipments Mode of Transportation Destination A)0Alef Page 4 of 5 ee em e

- - +

. m-

-,,._e_-

.. -.--w.,,---,cw.,

.-w,,,,r,

, mm ewe v, m,

.,g--

~

p.

. - Estimate of major nuclide composition (by type of waste) 2.a.

Spent resins, filter sludges, Percent I Activity (Curies) evaporator bottons, etc.

NN54 1.357 2.872E-1 C057 0.019 4.024E-3 C060 5.961 1.262 C058 22.509 4.765 ZN65 1.155 2.445E-1 Cl4 0.293 6.198E-2 NI63 0.125 2.642E-2 PU241 0.005 1.081E-3 H3 0.008 1.754E-3 CR51 67.692 1.433El CE144 0.323 6.832E-2 NA24 0.073 1.544E-2 W187 0.023 4.975E-3 CU64 0.078 1.646E-2 FE59 0.363 7.683E-2 1131 0.004 8.800E-4 CE141 0.012 2.474E-3 Total:

100%

2. l l7E l l

, - Estimate of major nuclide composition (by type of waste) 2.b.

Dry compressible waste, Percent %

Activity (Curies) contaminated equip, etc.

MN54 9.729 3.799E-3 C060 30.655 1.197E-2 C058 51.655 2.008E-2 CR51 1.511 5.899E-4 ZN65 1.701 6.642E-4 NI63 0.662 2.583E-4 Cl4 4.313 1.684E-3 H3 0.005 1.933E-6 Total:

100%

3.905E-2

)

l l

e I

(

=

79.000.50 R2v. 1 3'

4 WORKSHEET A-1 SOLID WASTE

SUMMARY

W3RKSHEET of[

Solt d Waste Categor 5 emf d5ars Ji4Ws f/u/4cs. AnwMt. esb.. Sheet

/

through S/ A2 (4 Reporting Period:

/ /r/ty fc Parameter Shipment Numbe r Total 1

2 3

4 5

1. Date (Mo/Da/Yr) 1[7/f6 1/f4/gf, 7/zt/pc y/pr/g F/4/gs, 3

l

2. Volune (m )

L f.i45"

+. o/ f 3,yy 84.o</3

,=,,9py

,go, z3y

3. Radioactivity Content (Ci) a. JM4 x estr,+

9429c-4

,.aw u 3 szs v.+ 1 92C r.4

.2. rig v.3 b. Ec57

c. Ceto 11956-5 f.ps c-2
4. iti c-3 1 stzc-3 29:3e5
2. ist E-2
d. (cyg t, /ragr4 t, m-3 2Sst., s-3

/ vsY#:-3 /. 99-? r-3

/. 23# E e.

~pu.{

f.

6A

/ #5'I E-3 12326-3

1..sf/ (-3

/. % 3 E-3 / %f E-3 7 5% E-3 24+3E-5" 21bE-4 R.L23 6-5'

_t" Co96-5 S*119 C-5 4 fors E-4 f

R.

Al b*b h.

fs. RI

+120E-?

2 rC/6-fr 4 Mb 6-1 6 tr2D E-7 (o. 220 E-? II.$W E-4

i. //.3

% a& r-s' 8152, c.Y 2nzcs s 1g3E s s nac-s- / rs7t-4 i

i. t'pri

?

k.

t*g/4/

1.

A;Me.

m.

zJif7 n.

Pubts o.

M]

p-Tt3i a.

CG/4r

4. Total Radio-E MS"l~~'3 13 3 5~E)* 3 #S*I'*5 YASE'~2" activity (Ci)
5. Type of container ort Ec, 52.

5;z gc, 7

6. Source of Waste 3ssJ Rwaneco knese N
  • W W-ne a -

g us,0 -

ger,,o -

emecou w conn m S44r conta maw

7. Processing O

Employed l

l

8. Solidification go g y,. y-4 x.*

x *.

Agent

  • STec44 TN47 ConTAt oc:*-

+u-h oArect w&q

.....w

... i

79.000.50 R2v. 1 g

WRKSHEET A-1 SOLID WASTE S120MRY WRKSHEET J of 1 Solid Waste Catego ySovd k r G W 9M nm ds el.

. Sheet

'through_

5t "Dec. tL Reporting Period:

t sut7 Parameter Shipment Number Total 1

2 3

4 5

1. Date (Mo/Da/Yr) g[g[g4 p[,3)fL g/fofr4 9/,f/g t/,r/t4 3
2. Volune (m )

. 3.10 7 5 137 g,fg4

4. izt,
y. 3,5 po. j9 3
3. Radioactivity Content (Ci) a.HvT4 4.1,11 r-+
t. itt e.2 6.942g.4

.t. err e-+

t. w r.1 b. L'os ")

fa. tile-4

/. o 91 E-+

c.

(cto

4. MCg-S

/ $@ c-1

4. 4o7g-3 I.oM c-4 242t. E-3 1o$r v-r
d. ccyg

> r#f E-3 7 a c,2

s. 4F7 E-3 3 stae-s-t.as F-3

/ irr c-2 e.

72.(

7 4fZ C-3 1 111E.4 fao E 3 f.

OtA 1.f31 E-3

4. fira.3 f.938 E-3 4 SME-4 / *E9ff 'l>

/.O M~E-2 R.

Ab l '"J

f. %4 E-4 4 D1R E-3

/. Set E-4 226 6-4

$~ I4S e-5 4.392 F-3 h.

Ar24

( 397 c-6 a 7wc-S*

1.ssy E.6 L toF-g 4 3 Toc.,

4 c2rg-s

i. // g u sL c-5' 3 4,37 c-5
3. w g arioc-r J of< e-r
1. gr+ ss
j. n r/

k.

I'f///

1.

Ai4 m.

zJef1 n.

l'ut//

O.

&3l v.

Tal o.

CG/41

4. Total Radio-

' 'T'&

  1. Wl I. 222 C-2. GME-f [ 2 1 E-3
5. as c.;

activity (Ci)

5. Type of Container frr.

srt str.

5,2 Se2

6. Source of Waste lh W
  • N 1krAb N

naso -

om o-eesa -

mas. s aes.a -

cmomsus' c.ontoper cec:cumuar on2==aA,r-

7. Processing Employed
  • -k
8. Solidification g,

up g *-

M*

Agent

  • STeo otn T6+T cmween_.

++ 'VEkATEb3g H4 MC a...,h.nt 1

79.000.50 Rev. 1

/

WORKSHEET A-1 l

SOLID WASTE SID01ARY W3RKSHEET (a)

,3 Solid Waste Category 5mha pie,es9.4ss.. h 6 h efc.

. Sheet 3 of g e sus et

' through s e turt Reporting Period:

i Parameter Shipment Number Total 1

2 3

4 5

1. Dnte '(HolDnlir) 10/21lf4 pojg,/gg

,,faslgg ggl gg/g4 gl2,fgg 3

2. Volume (m )

go gg g

g 74

3. Radioactivity Content (C1) a. //D 5"4

.t. 28 E-2 A4NE3 C224 62, i cN E.1 4 2'1.E-3 41stE-2.

b. res 7

/. fg f-3

/. hf E-3 I

c. (tt o 1.91Tc-1 8.mt 6-3

/ GfE-l 25% E-2

/.54Wa C '3-4 LECE-f

d. et$g 7s,or-/

7 sS s-2 y as E: /

f.sp? c-r 4;. s,2. e-2 Jos3 e.

pd.g

3 ffSE *b

/9% 63

.TLs2f 3 32% E-3 f.a6"E-l f.

Os4 4.'kat f 3

/9+3 E-3 A 414 6 3 2 M1 E _1s 23WE-5 I.447 E-2 E*

Af4.*b 4.I'W f-3 J. M/ E-4

.R bL E 3

4. n. C-+

2121 E 4

$.4A1E-5 h.

A,R/

i. // 9 7.1t+ E-s' fi. Soc 5 f us c-5 yin E-C r r,s c-s 4 ig2 c.4
i. H st 2.102 2 %oe-2

/.444 2 9a.e-2.

I L12 c ~t E rio j

k.

Mit/

)

1.

AM+

)

m.

zJif7 I

n.

fil/A o.

i';k27 5725 E-5 t,ME 3 see e-2 K+s1c 4. Mt.oE-1.

p.

Tdi 2 MSc-4 4 ofic-4 la.22L E-4 I

o.

CG/4t 2.+M c-3 X 4% E-3

4. Total Radto-3,,3

,gy, g,,sy g.,

,, g g,,,

4,4y, activity (C1)

5. Type of Container

$ra 5 72.

5 72-5'*

W N

h=^

N

6. Source of Waste lQ
  • w*w W 2*%a -

eesm-m-

hw j

p 1euca

7. Processing Employed

+4

-f d-

- + - + -

  1. -x
8. Solidification

.g.w

  1. g g

.g-g m

Agent

-F Smc*& TE(i hwat*-

4%

43 6 x+ A-I a

..+W.s.-w

. sw.e w-3

-wup w. -- *.

n ew..w

,%,.wc-

-,We

.u

.-ty w-

.,w O

79.000.50 Rev. 1

's WORKSHEET A-1 SOLID WASTE SIDOMRY W3RKSHEET CC Solid Waste Categoryht Au CherMs. Go b4*s., cic

. Sheet 4 of Reporting Period:

t hv 11, through st ~Cer 1r4 Parame te r Shipment Number Total 1

2 3

4 5

1. Date (MolDn(Yr) 9/24/fL

/0lWS4 toft /tL 10l:sgg sofi,/tt.

3

2. Volume (m )

3 219 4os3 4,g,g 34,7 g, q,

, q,g gy

3. Radioactivity Content (C1)
a. //DT4 C/fl f~ z

/.449c-4 2 65tE-4 4 Jto E-4 f.13b t.;- 5 S455V-2 b. (p5 7 C

(fl o 3 32r C-t I D9 E'- 3

,1. 2b3 E-B $ 117 t-3

(.,79 c-3 3_472 2-(

d. (cyg

/ 095 3 da2 c-3 fo29e-3

9. tot E-3

+. fn's-2.

/. a>o e.

-p u -C" S495e-2 f.t,% (-3 C.w4 g.1 f.

(b4 5 E5'e*3 f.124 E-3 18305-3

/ ~7,3 t~ E / 22s e-3 9 245E-3 R.

A/. 63

& 973r.3 3 ffb c-6 4 7f/ E-f inP7 E-4 1420c-4 7 W3 EL3

/ oM r-3 h.

Ar241

/oss'c-3

i. l} 9 Ss92 c-f g 774g-S g.qgz e-s-RA,6 E-g

,g.pto c 5 x 290E-4

i. l'DK/

f.2o 4 Sk f E-3 3.152 c.:s S.1f9 E 3 Ko40 C-1 t.'284 L.252 E-2 k.

l'A///

4.2s22-2 I.S++ E-2 1.

A,M+

i Sqqr-z m.

tJi??

4 97 s~ g-3 4475E-3

/L46 E-2 n.

l'abf/

/(4 E o.

RSr/

p.

D3/

4

[G/41

4. Total Radto-93,o
1. g ig c.2 j,jg. g.z

,,,,3 g,2,,,,,, c-g f, cosg, activity (C1)

M-

5. Type of Container str_

5 17-src.

GE SE

'N

6. Source of Waste

' as.s -

em.. -

m ecs.,a -

w-Nw*'

apenwa:- ccoo4 Ass cc m o p ic cce:nme

" '2" "

7. Processing Employed 4 Jc-e e-
8. Solidification we e

e x-y-

        • W Agent T Stembe TSAT co m eep
  • TEMKt4t.10g
  • + w

....w...,,

i

79.000.50 Rry. 1 s

WORKSHEET A-1 SOLID WASTE SUMV.4RY E)RKSHEET l

Solid Waste Categor Gut ht34r9uAc% 6vam.twsb.c'It.

. Sheet L of [

Reporting Period:

i sw/ e t "i

'through

% *bor at l

Parameter Shipaent Number Total 1

2 3

4 5

1. Date (Mo/Da/Yr) is/2.4/f4

/s./s/A.

/2 /9 /14 4?/ir/#4 /3/1/A-3

2. Volume (a )

L 3.724 3.13h 3.757

+sfo 5.153

/ f. /40

3. Radioactivity Content (C1) i
a. F/CT4 2 6996-3 A v.sc-3 S~492e-s
9. tost > 4. &lCE-3 AIS3C-!

). /05 ')

/ 45FG3

/. 43i e-3 j

c. (r&O

/ 979 E.Z 2 rige.3 2 qs5 C-2 f.192 E-f 2_ 625"E-1 2.620 E-t

d. CCSB

/.012. E-t 4.323 1-2 f.999 E-2 0.073 C11W E-2*

/.444 e.

72.(

f 9,S E-5

/. Cyb E-5 4f40E-3 6.4CL E-Z

3. 42 E-3 f.4SI 6-2

\\

l f.

Ch4 AS2SF3 198> E-3 S tVL E-3 4.222 E-3

2. 962 E-3 f.4 ant E-2 R.

A'. L 'b 3.161 C4

/ KS2 E-4 1.1&CE-4 B 'b2 E-3 S 440 6-4 CSm E-%

h.

Ao24I

i. // 9 19&fE-f 195g&S

? Ak,1E-f 2.927c-G" 1994e-C 4.o72 c-4

i. t*DKl 4.08/E l113 &'2-

? 145'E-2 A c31 4.950E-3 2 216

\\

l k.

I'K///

1.

N42+

a.

1J t f*?

n.

l'ttf//

l o.

sh21 4.f.01E-3 3 230C-4 2 021 & 4 21[L2-% 5 3tFE4 5 373 C ~2-

\\

p.

Tt3(

l.4 M E +

/.47+ E-4 a.

CG/4r

4. Tota 1 Radio-

,y g,,

e,g3 g,2,,,gg g-g 3.gg j_Sqgc-r 4, n g-activity (C1)

5. Type of Container Srt-97-5/E
6. Source of Waste IP*

ar o -

eu m.m -

nu -

m-N"r ca u= m rw caer cas:cocc o w e

7. Processing wa psii Employed y

y y

g w

8. Solidification
  • * * ~
  • * * ~

Agent

+ *sitsaA 'Wri contA.a

+ %%

++* Oe.ac a... u.e. 1

..___,_._.___________.__...,__....,__-____.._____,,,_.__._.__1

79.000.50 Rev. 1 4

.~

WORKSHEET A-1 SOLID WASTE SIMKARY W3RKSHEET Solid Waste Category %fh Q4,rMes Em h,6. A

. Sheet l of 2 l

through n tw ut

' ~

Reporting Period:

e su,/ nc i

Parameter Shipment Number Totel 1

2 3

4 5

1. Date (Mo/Da/Yr) s 2/r.2 /r4

/2/25/#4 is./af/24 3

2. Volume (m )

g%

m g

// - Sif I'

3. Radioactivity Content (Ci) a. ML*T4 J 103 r-3 1.fotE-3 f.99FE 1 TM E 3 b. z'r s 7

/

c. (no g_x-rE-s 4 ntr-s s sue-3

/

t. 999E~ 2
d. COSB 2 -rst E-2 f.n4 E-1 2.tss e-2.

I L. 4 4-E-2 f

& avz.e-+

e.

jM 4 ryz t-4 f.

64 111ct-3 155LE-3

1. ?s9E-1 l

S.oto E-3 x-Al L,'>

f. 4 E-4 2 k2 E-T

/ 31fE-+

l 3.*LS9 E-4 h.

A,Rt

/

i. H9 711t.E-5 1.21E-C 7.192 E;-S l

of.314 E-4

i. H KI
1. u 3 E-3 4.Seh'r-3 2% o e-3

/

f:%O E*2.

k.

Mg/

/

1.

N4-2o.

/

m it?

/

i m.

n.

/'u/A

/

o.

Asr/

/

v.

Till

/

Q

[G/41

[

4. Total Radio-3.44s e.z 2xte-z 4.zas e-z
t. 018 e-(

activity (C1)

5. Type of Container
  • srz 5;z siz:.
6. Source of Waste i

acab prim F"

12cs0 esks -

W-1

7. Processing Employed 4-*-

1

8. Solidification pp
  1. w Agent W-S7Eo06 7%W G:A Msde*-

+- +

WATee:D6 N # V' doc (

l,

'****'"*"']

79.000.50 Rev. 1 f

- WRKSHEET A-1 l

SOLID WASTE

SUMMARY

WRKSHEET i

e,..

,,t., watde, con-(s 'eale 0 Uc Solid Waste CategorA )Wycougrew

/

. Sheet 1

of l b

e suty sc.

through 1p bcz e L U '

l Reporting Period:

Parameter Shipment Nu:ber Total 1

2 3

4 5

1. Date (Mo/Ds/Yr)

Sp3/f(,

3

2. Volume (z )_

n,W y

l-

3. Radioactivity

(

Content (Ci) c.

  1. 4 64 4 199 (- 3 3.7M E-3 l

b.

tw,o 1.191gef 2

1. iqy c.2 c.

scr2 1.d[.2 2d E-z gJ95 (-4 d.

frAr/

fJyf E-4 e.

2ac L.u2 c-4 f,.uz t-4 l

f.

Alito3

2. G3[-4
2. s23 E-4

\\

E.

8/4 f.M4 E-5

1. foM E-3 h.

H3

3. 933E-lo

/.953 Ed.

i.

j.

k.

1.

m.

n.

O.

P.

R-

4. Total Radio-J,gE-1 J.ME L activity (C1)

+

5. Type of Container 5 74,
6. Source of Waste M / M T' #

AAssT4

7. Processing l.

Employed

8. Solidification Agent etuong Te(I conscet l

l t

l

E!EIDSURE 6 f1ETER10GICAL DA%

9

-m

,.m.

-+--- --- - - - -,,-

I REPORT CATEGORY

NETEROLOGICAL DATA.

QUARTERLY TOTALS OF EOi1RS. AT EACB WIND SPEED AND DIRECTION PERIOD OF RECORD

QUARTER ~ 9 1

REPORT START TIME

0:00 'ERS = 12: 00AM J ANUARY -1,1986 REPORT END TIME
2159:59 BRS = ll:59PM MARCH 31, 1986 STABILITY CLASS
A ELEVATION 10 METERS WIND SPEED (MPH) AT 10 METER LEVEL

>2(

TOTAL 1-3 4-7 8-12 13-18 19-24 N
0.00E-01 : 0.00E-01 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

NNE: 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

l NE : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01;: 0.00E-01 : 0.00E-01 : 0.00E-01:

~

~

~~

~

~~

~

~~

~

~

~

~~

~

~~

~

5U5: 6!0di-0[ t 5!dd5-0[ s 5!d05-0[ I 0!005-d[ I"570EE-d[ s 0IOOk-0[ I dIOOE-0EI E

0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

ESE: 0.00E-01 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00 E-01:

SE : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.60 E-Cl 1

l SSE: 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

1 S

0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00 E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

SSN: 0.00E-01 : 1.00E 00 : 4.00E 00 : 1.00E 00 : 0.00E-01 :.0.00E-01 : 6.00E 00:

SW 0.00E-01 : 3.00E 00 4.00E 00 : 1.00E 00 : 0.00E-01

~ 0.00 E-01 : 8.00E 00 WSN: 0.00E-01 : 4.00E 00 : 8.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.20E 01:

4

________________.___________.u W

0.00E-01 : 3.00E 00 : 6.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 9.00E 00:

WNW: 0.00E-01 : 1.00E 00 : 3.00E 00 : 0.00E-01 : 0.00E-01 0.00E-01 z 4.005 OC:

l NW 0.00E-01 : 0.00E-01 : 0.00E-01 e 4.00E 00 : 0.00E-01 : 0.00E-01 : 4.00E 80's j

~

l NNW: 0.00E-01 : 0.00E-01 : 0.005-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

TOT: 0.005-01 : 1.20E 01 : 2.6 0E 01 : 6.00E 00 : 0.00E-01 : p.00E-01 : 4.40E 01:

l PERIODS OF CALM (HOURS):

0.000E-Ol HOURS OF INVALID DATA :

0.000E-Ol' t

l

{

}

1 l

.REPO3T CATEGORY

NETEROLOGICAL DATA.

QUARTERLY TOTALS OF EOURS AT i

EACE WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 6 1

l REPORT START TIME

0:00 BRS = 12:00AM JANUARY 1,1986 REPORT.END TIME
2159:59 HRS = 11:59PM MARCH 31, 1986 l

STABILITY CLASS

B ELEVATION 10 METERS WIND SPEED (MPH) AT 10 METER LEVEL 1-3 47 8-12 13-18 1 9-24

>24

TOTAL N
0.00E-01 : 0.00 E-01 3.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 4.00E 00s NNE: 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

N 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00 E-01~ : 0.00E-01 : 0.0 0 E-01:

1 E:

ENE: 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00 E-01:

E

0.00E-01 : 1.00E 00 : 1.00E 00 : 0.00 E-01 0.00 E-01 : 0.00E-01 : 2.00E 00:

ESE: 0.00E-01 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00 E-01 : 0.00 E-01 : 1.00E 00 SE : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

SSE: 0.00E-01 : 0.00 E-01 0.00 E-03 : 0.00E-01 ? 0.00E-01 : 0.00 E-01 : 0.00E-01:

l 8

0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00 E-01:

SSW: 0.002-01 : 0.00 E-01 4.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 5.00E 00 SW s' O.00E-01 : 1.00E 00 : 4.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 6.00E.00 WSK 'O.00E-01 : 0.00E-01 : 5.00E 00 : 1.00E 00 : 0.00 E-01 : 0.00E-01 : 6.00E 00:'

W

0.00E-01 : 2.00E 00 : 3.00E 00 : 0.00E-01 : 0.0 0 E-01 : 0.00E-01 : 5.00E 00 WNW: 0.00E-01 : 2.00E 00 : 5.00E 00 : 0.00E-01 : 0.0 0 E-01 : 0.00E-01 7.005 00s NW s ' O.00 E-01 : 0.00E-01 : 1.00E 00 : 3.00E 00 0.00E-01 : 0.00E-01 : 4.00E 00:

NNW: 0.00E-01 : 0.00E-01 : 0.00 E-01 : 0.00E-01 : 0.00 E-01 : 0.00E-01 : 0.00 E-01:

TOT ~0.00E-01 : 7.00E 00 2.60E 01 7.00E 00 0.00E-01 : 0.00E-01 : 4.00E 01:

PERIODS OF CALM (HOURS):

0.000 E-01 E00RS OF INVALID DATA :

0.000E-01

k O

REPORT CATEGORY

NETEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

.)

EACH WIND SPEED AND. DIRECTION PERIOD OF RECORD
QUARTER 9 1

REPORT START TIME

0:00 BRS = 12:00AM JANUARY 1,1985 REPORT END TIME
2159:59 BRS = ll:59PM MARCH 31, 1986 STABILITY CLASS
C BLEVATION 10 METERS l

WIND SPEED (MPE) AT 10 METER LEVEL l

1-3 4-7 8-12 13-1 8 19-24

>24

TOTAL N
0.00E-01 : 0.00E-01 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

NNEs 0.00E-01 : - 0.00E-01 : 0.90E-01

.0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

~

NE

~0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

l ENE: 0.00E-01 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00 E-01:

l E

0.00E-01 : 1.00E 00 : 1.00E 00 0.00E-01 : 0.00 E-01 : 0.00E-01 : 2.00E 00 l

ESE: 0.00E-01 : 0.00E-01 : 3.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 3.00E 00:

SE : 0.00E-01 : 1.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.00E 00:

SSE: 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00 E-01 0.00 E-01 :

S

0.00E-01 : 0.00E-01 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.00E 00:

SSW: 1.00E 00 : 0.00 E-01 : 4.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 5.00E 00:

l SW 0.00E-01 : 1.00E 00 : 4.00E 00 : 0.00E-Ol : 0.00E-01 : 0.00E-01 : 5.00E 00:

WSW 1.00E 00 : 3.00E 00 : 7.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 1.20E 01:

W 0.00E-01 : 0.00 E-01 : 2.00E OG : 0.00E-01 : 0.00 E-01 : 0.00E-01 : 2.00E 00 WNW: 0.00E-01 : 7.00E 00 : 1.00E 00 : 0.00E-01 : 0.00 E-01 : 0.00E-01 : 8.00E 00:

NW 0.00E-01 : 0.00 E-01 3.00E 00 3.00E 00 : 0.00E-01 : 0.00 E-01 : 6.00E 00:

NNW: 0.00E-01 : 1.00E 00 : 2.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 4.00E 00:

TOT: 2.00E 00 : 1.40 E 01 2 3.10E 01 s 5.00E 00 0.00E-01 : 0.00E-01 : 5.20E 01:

PERIODS OF CALM (BOURS):

0.000E-01 HOURS OF INVALID DATA :

0.000E-01

!^

REPORT CATEGORY

NETEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD

QUARTER"9 1-REPORT START TIME
0: 00 - BRS = 12: 00AM JANUARY 1,1986 REPORT END TIME
2159:59 BRS = 11:59PM MARCH 31, 1986 STABILITY CLASS
D ELEVATION 10 METERS WIND SPEED (MPE) AT 10 METER LEVEL 1-3 4-7 8-12 13-18 19-24

>24

TOTAL bN 3.005 00 : 8.00E 00 : 9.00E 00 : 1.20E 01 : 0.00E-01 : 0.00E-01 : 3.20E 01:

NNE " 2.00E 00 : 5.00E 00 6.00E 00 : 7.00E 00 : 0.00E-01 : 0.00E-01 : 2.00E 01:

NE

. 1.00E 00 : 4.00E 00 7.00E 00 : 4.00E 00 : 1.00E 00 : 1.10E 01 : 2.80E 01:

ENE: 3.00E 00 : 2.00E 00 2.00E 00 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 9.00E 00:

E

1.00E 00 : 5.00E 00 : 1.6 0E 01 : 8.00E 00 0.00 E-01 0.00E-01 : 3.00E 01:

ESE: 4.00E 00 2.00E 00 : 1.90E 01 : 8.00E 00 : 1.00E 00 : 0.00E-01 2 3.40E 01:

SE :~ 3.00E 00 : 6.00E 00 : 1.5 0 E 01 9.00E 00 : 0.00E-01 : 0.00E-01 : 3.30E 01:

SSE: 3.00E 00 : 6.00E 00 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00 E-01 : 1.20E 01:

S

1.00E 00 : 8.00E 00 1.30E 01 : 3.00E 00 0.00E-01 : 0.00E-01 : 2.50E 01:

SSN: 1.00E 00 : 6.00E 00 2.4 0 E 01 : 7.00E 00 : 0.0 0 E-01 : 0.00E-01 : 3.80E 01:

SW : 1.00E 00 : 6.00E 00 3.5 0 E 01 : 9.00E 00 : 1.00E 00 0.00E-01 : 5.20E 01:

WSW: 5.00E 00 : 1.7 0E 01 : 2.4 0 E 01 : 1.10E 01 : 9.00E 00 : 0.00 E-01 : 6.6 0E 01:

W

~ 6.00E 00 : 1.3 0E 01 : 1.10E 01 : 1.20E 01 : 2.00E 00 : 0.00E-01 : 4.40E 01:

WNW: 4.00E 00 : 2.5 0 E 01 : 9.00E 00 : 1.10E 01 : 1.00E 00 : 0.00E-01 : 5.00E 01:

NW 1.00E 00 : 1.3 0E 01 : 1.70E 01 : 2.50E 01 : 0.00E-01 : 0.00E-01 : 5.6 0E 01:

NNW: 2.00E 00 : 1.6 0E 01 : 2.40E 01 : 1.7 0E 01 : 1.00E 00 : 0.00E-01 : 6.~0 0 E 01 :

TOT: 4.10E 01 : 1.42E 02 : 2.34E 02 : 1.45 E 02 : 1.6 0E 01 : 1.10E 01 : 5.89E 02:

- PERIODS OF CALM (BOURS):

0.000 E-01 HOURS OF INVALID DATA :

0.000 E-01 W

REPORT CATEGORY

NETEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

'EACH WIND SPEED AND DIRECTION PERIOD OF REOORD
QUARTER 4 1

REPORT START TIME

0: 00 BRS = 12: 00 AM J ANUARY 1, 1986 REPORT END TIME
2159:59 BRS = 11:59PM MARCH 31, 1986 STABILITY CLASS
E ELEVATION 10 METERS WIND SPEED (MPB) AT 10 METER LEVEL 1-3 4-7 8-12 13-18 19-24

>24

TOTAL I

N s 'l.00E 00 : 1.30E 01 : 6.00E 00 : 1.6 0E 01 : 0.00E-01 : 0.00E-01 2 3.6 0E 01:

NNE: 1.00E 00 : 1.70E 01 : 1.20E 01 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 3.30E 01:

l NE : 3.00E 00 : 1.00E 01 : 1.7 0E 01 : 9.00E 00 6.00E 00 0.00E-01 : 4.50E 01:

ENE: 0.00E-01 : 6.00E 00 : 1.80E 01 : 7.00E 00 : 0.00E-01 : 0.00E-01 : 3.10E 01:

2 l. - - - -.. _ _ _ _ -. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _. _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _....

E

0.00 E-01 :. l.20 E 01 : 8.00E 00 : 6.00E 00 : 0.00E-01 : 0.00E-01 : 2.60E 01:

i ESE: 0.00E-01 : 7.00E 00 : 1.39E 01 : 4.00E 00 0.00E-01 : 0.00E-01 2.40E 01:

l SE s'4.00E 00 7.00E 00 : 1.00E 01 : 7.00E 00 0.00E-01 : 0.00E-01 : 2.80E 01:

( SSE: 8.00E 00 : 1.80E 01 : 1.6 0E 01 : 8.00E 00 0.00E-01 : 0.00E-01 : 5.00E 01:

S

4.00E 00 : 1.10E 01 : 3.00E 00 : 7.00E 00 : 0.00E-01 : 0.00E-01 : 2.5 0E 01:

SSW: 7.00E 00 : 1.10E 01 : 2.80E 01 : 1.60E 01 : 0.00E-01 : 0.00E-01 : 6.20E 01:

SW

  • 6.00E 00 : 2.40E 01 : 2.20E 01 : 1.30E 01 : 0.00E-01 : 0.00E-01 : 6.50E 01:

WSW: 2.00E 01 : 3.90E 01 : 2.50E 01 : 2.30E 01 : 1.70E 01 : 1.00E 00 : 1.25E 02:

U 2.20E 01 2 3.10E 01 : 1.6 0E 01 : 1.90E 01 : 2.00E 00 : 0.00E-01 : 9.00E 01:

l lWNW: 6.00E 00 : 3.50E 01 : 2.10E 01 : 7.00E 00 : 1.00E 00 : 0.00E-01 : 7.00E 01:

NW : 6.00E 00 : 2.30E 01 : 1.908 01 : 9.00E 00 : 0.00E-01 : 0.00E-01 : 5.70E 01:

l ___--_. _- _____.. ___ -_--____________-____________________________________ __.

NNW: 2.00E 00 : 1.30E 01 : 1.10E 01 : 1.80E 01 : 1.00E 00 : 0.00E-01 : 4.50E 01:

TOTS' 9.00E 01 : 2.77E 02 : 2.45E 02 : 1.72E 02 : 2.70E 01 : 1.00E 00 : 8.12E 02:

PERIODS OF CALM (HOURS):

4.000E 00 BOURS OF INVALID DATA :

0.000E-01 l

7,

  • e v

m~...,_-.,.-_.,.--.._.m.__

.,.___--____-v.

,-,,..,y.

1 1

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT l

EACB WIND SPEED AND DIRECTION l

PERIOD OF RECORD.

s' QUARTER 9 1

REPORT START TIME

0:00 HRS = 12:00AM JANUARY 1,1986 l

REPORT END TIME

2159:59 BRS = 11:59PM MARCH 31, 1986 STABILITY CLASS F

ELEVATION 10 METERS WIND SPEED (MPE) AT 10 METER LEVEL

l l-3 4-7 8-12 13-1 8 19-24

>24

TOTAL N
6.00E 00 5.00E 00 : 4.005 00 : 4.00E 00 0.00E-01 : 0.00E-01 : 1.90E 01:

____~_______________ ____________________________________________________________

j NNE: 5.00E 00 5.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 01:

NE : 1.00E 00 : 5.00E 00 : 7.00E 00 1.00E 00 0.00E-01 : 0.00E-01 : 1.40E 01:

ENE: 1.00E 00 : 3.00E 00 2.00E 00 : 1.3 0 E 01 : 0.00E-01 : 0.00E-01 : 1.90E 01:

E

0.00E-01 : 1.00E 00 : 1.00E 00 : 3.00E 00 : 0.00 E-01 : 0.00E-01 : 5.00E 00:

ESE: 3.00E 00 : 0.00 E-01 : 2.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 6.00E 00:

SE : 7.00E 00 : 5.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.20E 01:

SSE: 6.00E 00 6.00E 00 : 4.00E 00 1.00E 00 0.00E-01 : 0.00E-01 : 1.70E 01:

S

3.00E 00 6.00E 00 6.00E 00 : 0.00E-01 : 0.00 E-01 : 0.00 E-01 : 1.50 E 01:

j SSW: 2.00E 00 : 8.00E 00 : 3.00E 01 : 5.00E 00 : 0.00E-01 : 0.00E-01 : 4.50E 01:

SW s ' l.00 E 01 1.00 E 01 : 2.40E 01 4.00E 00 : 1.00E 00 : 0.00E-01 : 4.90E 01:

WSN: 1.30E 01 : 1.10E 01 3.00E 00 : 2.00E 00 0.00E-01 : 0.00E-01 : 2.90E 01:

W

1.40E 01 : 5.00E 00 : 0.00E-01 : 0.00 E-01 : 0.00E-01 : 0.00E-01 : 1.90E 01:

WNW: 4.00E 00 : 1.30E 01 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00 E-01 : 2.00E 01:

NW

~ 1.00E 01 : 1.20E 01 : 7.00E 00 1.00E 00 0.00E-01 : 0.00E-01 : 3.00E 01:

-NNW: 3.00E 00 : 9.00E 00 3.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.'50E 01:

TOT: 8.80E 01 : 1.04E 02 : 9.6 0E 01 3.50E 01 : 1.00E 00 : 0.00E-01 3.24E 02:

PERIODS OF CALM (BOURS):

7.000E 00 t

l HOURS OF INVALID DATA :

0.000E-01

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACB WIND SPEED AND DIRECTION PERIOD OF REOORD
QUARTER'S 1

REPORT START TIME

0:00 BRS = 12:00AM JANUARY 1,1986 L

REPORT END TIME

2159:59 BRS = 11:59PM MARCH 31, 1986 STABILITY CLASS
G ELEVATION 10 METERS WIND SPEED (MPH) AT 10 METER LEVEL l

1-3 4-7 8-12 13-1 8 19-24

>24

TOTAL i

l N

4.00E 00 : 6.00E 00 6.00E 00 : 5.00E 00 : 0.00E-01 : 0.00 E-01 : 2.10E 01:

NNE: 5.00E 00 2.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 8.00E 00:

NE : 2.00E 00 : 2.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00 E-01 : 4.00E 00:

I ENE: 5.00E 00 : 0.00E-01 : 4.00E 00 2 4.00E 00 : 0.0.0E-01 : 0.00E-01 : 1.3 0E 01:

E

2.00E 00 : 8.00E 00 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.10E 01.

ESE: 5.00E 00 : 4.00E 00 : 1.00E 60 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 01:

SE_: 6.00E 00 6.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 0.00E-01 : 1.20E 01:

i

(

SSE: 1.00E 00 : 6.00E 00 : 6.00E 00 : 3.00E 00 : 0.00E-01 : 0.00 E-01 : 1.60E 01:

l 8

1.00E 00 5.00E 00 : 1.20E 01 1.00E 00 : 0.00E-01 : 0.00E-01 : 1.90E 01:

SSN: 0.00E-01 3.00E 00 3.10E 01 : 1.00E 01

- 0.00E-01 : 0.00E-01 : 4.40E 01:

SW : 3.00E 00 : 4.00E 00 : 1.00 E 01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.7 0E 01:

WSW: 3.00E 00 : 2.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 6.00E 00:

W

2.00E 00 : 7.00E 00 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.20E 01:

WNW: 2.00E 00 5.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.10E 01:

NW : 2.00E 00 : 5.00E 00 0.00 E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 7.00E 00:

i NNW: 7.00E 00 : 2.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1. DOE 01:

l TOT: 5.00E 01 : 6.70E 01 : 8.10E 01 : 2.3 0E 01 : 0.00E-01 : 0.00E-01 : 2.21E 02:

i PERIODS OF CALM (HOURS):

1.000E 00 HOURS OF INVALID DATA :

0.000E-01 HOURS OF GOOD DATA 2.0 94E 03 =

96.9% OF TOTAL HOURS

l i

REPORT' CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT a EACB WIND SPEED AND DIRECTION i

PERIOD OF RECORD

QUARTER 9 1
l. REPORT START TIME
0:00 BRS = 12:00AM JANUARY 1,1986 i

REPORT END TIME

2159:59 BRS = 11:59PM MARCH 31, 1986 i

STABILITY CLASS

A
ELEVATION 60 METERS WIND SPEED (MPB) AT 60 METER LEVEL 1-3 4 -7 8-12>

13-18 19-24

>24

TOTAL N
0.00E-01 : 0.00E-01 : 0.00E-Ole: 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

' - NNE::' _O.00E-01 : 0.00E-01 : 0.00E,0.1 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

NE s ' O.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

ENE: 0.00 E-01 0.00E-01 : 0.0 0 E-01 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

l I

E

0.00E-01 : 0.00 E-01 : 0.00 E-01 : 0.00E-01 : 0.0 0 E-01 : 0.00E-01 : 0.00E-01:

ESE: 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

SE : 0.00E-01 : 0.0 0 E-01 : 0.00 E-01 : 0.00E-01 : 0.0 0 E-01 : 0.0 0 E-01 : 0.00 E-01:

SSE: 0.00 E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00 E-01 : 0.00E-01:

S

0.00E-01 : 0.00 E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00 E-01 : 1.00E 00:

SSW: 0.00 E-01 : 0.00 E-01 : 1.00E 00 : 3.00E 00 : 1.00E 00 : 0.00E-01 : 5.00E 00:

SW : 0.0 0 E-01 : 2.00E 00 : 3.00E 00 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 8.00E 00:

WSW: 0.00E-01 : 1.00E 00 8.00E 00 : 7.00E 00 0.00E-01 : 0.0 0 E-01 : 1.6 0E 01:

W s'0.00E-01 : 0.00E-01 : 5.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 5.00E 00:

4 WNW: 0.00E-01 : 0.00E-01 3.00E 00 : 1.00E 00 : 2.00E 00 : 0.00E-01 : 6.00E 00:

NW 0.00E-01 : 0.00 E-01 : 0.00E-01 : 0.00E-01 : 2.00E 00 0.00E-01 : 2.00E 00:

l NNW: 0.00E-01 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

l TOT: 0.00E-01 : 3.00E 00 : 2.20E 01 : 1.4 0 E 01 : 5.00E 00 : 0.00E-01 : 4.40E 01:

PERIODS OF CALM (HOURS):

0.000E-01 HOURS OF INVALID DATA :

0.000E-01 t

i

.,#_u-~..,.-

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 8 1

REPORT START TIME

0:00 BRS = 12:00AM JANUARY 1,1986 REPORT END TIME
2159:59 HRS = 11:59PM MARCH 31, 1986 STABILITY CLASS
B BLEVATION 60 METERS WIND SPEED (MPH) AT 60 METER LEVEL 1-3 4-7 8-12 13-18 19-24

>24

TOTAL N
0.00E-01 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 0.00E-01 : 0.00E-01:

NNE:* 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

NE : 0.00E-01 : 0.00E-01 i 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

ENE: 0.00E-01 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

E

0.00E-01 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00 ESE: 0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00

[

SE : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

- SSE: 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 0.00E-01 : 0.00E-01:

S

0.00E-01 : 0.00E-01 : 1.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 2.00E 00:

SSN: 0.00E-01 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 1.00E 00 : 0.00E-01 : ?. 00E 00:

SW 0.00E-01 : 1.00E 00 : 1.00E 00 7.00E 00 : 0.00E-01 : 0.00E-01 : 9.00E 00:

WSN: 0.00E-01 : 1.00E 00 : 5.00E 00 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 9.00E 00:'

W s'0.00E-01 : 0.00E-01 : 1.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 2.00E 00 WNW: 0.00E-01 : 0.00E-01 4.00E 00 2.00E 00 : 1.00E 00 0.00 E-01 : 7.00E 00:

NW : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.00E 00 : 0.00E-01 : 2.00E 00:

NNW: 0.00E-01 : 0.00E-01 2.00E 00 2.00E 00 : 0.00E-01 : 0.00E-01 : 4.00E 00:

TOT: 0.00E-01 : 4.00E 00 : 1.6 0E 01 : 1.6 0E 01 4.00E 00 : 0.00E-01 : 4.00E 01:

PERIODS OF CALM (HOURS):

0.000E-01 HOURS OF INVALID DATA :

0.000E-01 hummmumuunummmm mm.m.

b uu

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 6 1

i REPORT START TIME

0: 00 HRS = 12: 00 AM J ANU ARY 1, 1986 REPORT END TIME
2159:59 BRS = 11:59PM MARCH 31, 1986 l

STABILITY CLASS

C ELEVATION 60 METERS WIND SPEED (MPH) AT 60 METER LEVEL 1-3 4-7 8-12 13-18 19-24

>24

TOTAL N

.0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

___.--__.s,__--____.-_________-_______-_______

NNE: 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

NE : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

ENE: 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

E

0.00E-01 : 1.00E 00 0.00E-01 : 2.00E 00 0.00E-01 : 0.00E-01 : 3.00E 00:

ESE: 0.00E-01 : 0.00E-01 : 1.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 2.00E 00:

SE : 0.00E-01 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 0.00E-01 : 1.00E 00:

SSE: 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

S

0.00E-01 : 0.00 E-01 : 2.00E 00 2.00E 00 : 0.00E-01 : 0.00E-01 4.00E 00:

SSW: 1.00E 00 2 0.00E-01 : 1.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 3.00E 00:

SW 0.00E-01 : 1.00E 00 : 2.00E 00 : 7.00E 00 : 0.00E-01 : 0.00E-01 : 1.00E 01:

WSW: 1.00E 00 : 2.00E 00 : 2.00E 00 2.00E 00 : 1.00E 00 0.00E-01 : 8.00E 00 '

W 0.00E-01 : 1.00E 00 0.00E-01 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 3.00E 00:

1 WNW: 0.00E-01 : 1.LGE 00 : 6.00E 00 : 1.00E 00 : 3.00E 00 : 0.00E-01 : 1.10E 01:

)

l NW 0.00E-01 : 0.00E-01 : 0.00E-01 3.00E 00 : 1.00E 00 : 0.00E-01 4.00E 00:

)

i NNW: 0.00E-01 : 1.00E 00 : 1.00E 00 2 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.'00E 00:

TOT: 3.00E 00 : 7.00E 00 : 1.6 0E 01 : 2.10E 01 : 5.00E 00 : 0.00E-01 : 5.20E 01:

PERIODS OF CALM (HOURS):

0.000 E-01 HOURS OF INVALID DATA :

0.000 E-01 l

l l

, REPORT: CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT l

EACE WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 9 1

l REPORT START TIME

0:00 BRS = 12:00AM JANUARY 1,1986 l REPORT END TIME
2159:59 HRS = 11:59PM MARCH 31, 1986 STABILITY CLASS
D ELEVATION 60 METERS WIND SPEED (MPH) AT 60 METER LEVEL 1-3 4-7 8-12 13-18 19-24

>24

TOTAL N
2.00E 00 : 7.00E 00 7.00E 00 : 2.00E 00 : 0,00E-01 : 0.00E-01 : 1.80E 01:

NNE: 2.00E 00 5.00E 00 3.00E 00 6.00E 00 2.00E 00 0.00E-01 : 1.80E 01:

NE.: 1.00E 00 : 1.00E 00 : 1.00E 00 : 9.00E 00 : 1.00E 00 9.00E 00 2.20E 01:

ENE: 3.00E 00 2.00E 00 : 3.00E 00 : 0.00E-01 : 2.00E 00 3.00E 00 : 1.30E 01:

E

2.00E 00 : 5.00E 00 : 8.00E 00 : 1.5 0 E 01 : 8.00E 00 2.00E 00 : 4.00E 01:

ESE: 3.00E 00 5.00E 00 : 1.10E 01 : 1.6 0E 01 : 5.00E 00 : 1.00E 00 : 4.10E 01:

SE : 4.00E 00 5.00E 00 : 6.00E 00 2.00E 00 : 0.00E-01 : 0.00E-01 : 1.7 0E 01:

SSE: 3.00E 00 : 3.00E 00 : 4.00E 00 3.00E 00 0.00E-01 : 0.00E-01 : 1.30E 01:

S

1.00E 00 2.00E 00 : 1.80E 01 : 1.30E 01 : 1.00E 00 0.00E-01 3.50E 01:

SSW: 3.00E 00 5.00E 00 : 6.00E 00 : 1.30E 01 : 4.00E 00 2.00E 00 3.30E 01:

i SW 3.00E 00 : 1.00E 00 : 1.30E 01 : 3.10E 01 : 1.00E 00 : 1.80E 01 : 6.70E 01:

i WSW: 2.00E 00 : 6.00E 00 : 1.20E 01 : 2.20E 01 : 8.00E 00 : 1.00E 01 : 6.00E 01:

W

5.00E 00 : 9.00E 00 : 7.00E 00 : 8.00E 00 : 2.00E 00 : 1.30E 01 4.40E 01:

WNW: 2.00E 00 : 1.00E 01 : 2.20E 01 : 1.10E 01 : 1.90E 01 4.00E 00 6.80E 01:

1 l

NW 0.00E-01 : 9.00E 00 : 1.30E 01 : 1.80E 01 : 1.6 0E 01 : 3.00E 00 : 5.90E 01:

j NNW: 1.00E 00 : 1.10E 01 : 1.3 0E 01 : 8.00E 00 : 5.00E 00 3.00E 00 : 4.10E 01:

l TOT: 3.70E 01 : 8.60E 01 : 1.47E 02 : 1.77 E 02 : 7.40 E 01 : 6.80E 01 : 5.89E 02:

PERIOD 6 OF CALM (BOURS):

0.000E-01 HOURS OF INVALID DATA :

0.000E-01 i

l

. _ _ _ _ _., _ _ _.. _. _.. _ ~ ~ _ _

REPORT CATEGORY

NETEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED 'AND DIRECTION PERIOD OF RECORD
QUARTER 9 1

REPORT START TIME

0: 00 BRS = 12: 00AM J ANUARY 1, 1986 REPORT END TIME
2159:59 BRS = ll:59PM MARCH 31, 1986 STABILITY CLASS
E ELEVATION 60 METERS WIND SPEED (MPH) AT 60 METER LEVEL l_3 4-7 8-12 13-18 19-24

>24

TOTAL N
1.00E 00 : 4.00E 00 : 6.00E 00 : 1.00E 00 : 1.00E 00 0.00E-01 : 1.30E 01:

NNE: 0.00E-01 : 2.00E 00 a 2.30E 01 5.00E 00 3.00E 00

0.0 0E-01-

3.30R 01:

4 NE : 2.00E 00 : 7.00E 00 : 1.70E 01 : 1.00E 00 : 8.00E 00 5.00E 00 4.00E 01:

ENE: 0.00E-01 : 4.00E 00 : 1.10E 01 : 1.20E 01 : 9.00E 00 : 0.00E-01 3.60E 01:

E

2.00E 00 : 9.00E 00 : 1.00E 01 : 9.00E 00 : 7.00E 00 : 1.00E 00 : 3.80E 01:

ESE: 1.00E 00 : 2.00E 00 : 5.00E 00 1.90 E 01 : 3.00E 00 0.00E-01 : 3.00E 01:

SE : 2.00E 00 5.00E 00 : 1.50 E 01 : 1.00E 01 : 4.00E 00 : 0.00E-01 3.60E 01:

SSE: 3.00E 00 : 2.00E 01 : 8.00E 00 : 5.00E 00 : 0.00E-01 : 0.00E-01 : 3.60E 01:

S s'l.00E 00 : 5.00E 00 : 7.00E 00 : 1.20 E 01 : 2.00E 00 : 7.00E 00 3.40E 01:

SSW: 1.00E 00 : 9.00E 00 : 8.00E 00 : 6.00E 00 : 1.20 E 01 : 1.50 E 01 : 5.10E 01:

SW 2.00E 00 : 5.00E 00 : 1.90E 01 : 3.10E 01 : 2.10E 01 2 3.30E 01 : 1.llE 02:

WSW: 5.00E 00 : 1.20E 01 : 3.70E 01 : 2.7 0E 01 : 1.90E 01 : 1.10E 01 : 1.llE 02:.

W

2.00E 00 : 1.30E 01 : 2.40E 01 : 2.80E 01 3.00E 00 5.00E 00 7.50E 01:

i WNW: 2.00E 00 : 7.00E 00 : 2.00E 01 : 2.30E 01 : 5.00E 00 : 7.00E 00 : 6.40E 01:

NW s' 2.00E 00 : 7.00E 00 : 2.00E 01 : 1.3 0E 01 : 2.10E 01 : 1.00E 00 : 6.40E 01:

~

NNW: 0.00E-01 : 7.00E 00 : 8.00E 00 : 1.7 0E 01 : 9.00E 00 3.00E 00 : 4.40E 01:

TOT: 2.60E 01 : 1.18E 02 : 2.38E 02 : 2.19E 02 : 1.27E 02 : 8.80E 01 : 8.16 E 02:

PERIODS OF CALM (HOURS):

0.000E-01 HOURS OF INVALID DATA :

0.000E-01 w---

~--n

-e--,------

_,--,,---,--,-,an,-w a

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF REOORD
QUARTER 4 1

l REPORT START TIME

0: 00 HRS = 12: 00AM JANUARY 1,1986 REPORT END TIME
2159:59 HRS = ll:59PM MARCH 31, 1986 STABILITY CLASS
F ELEVATION 60 METERS i

WIND SPEED (MPH) AT 60 METER LEVEL 1-3 4-7 8-12' 13-18 1 9-24

>24

TOTAL N
1.00E 00 6.005 00 : 2.00E 00 : 4.00E 00 : 1.00E 00 0.00E-01 : 1.40 E 01:

NNE: ' 0.00E-01 : 8.00E 00 : 5.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.30E 01:

l NE : 1.00E 00 : 7.00E 00 3.00E 00 : 3.00E 00 : 0,00E-01 : 0.00E-01 : 1.40E 01:

ENE: 0.00E-01 : 4.00E 00 : 3.00E 00 : 3.00E 00 : 1.10E 01 : 2.00E 00 : 2.30E 01:

E

1.00E 00 : 3.00E 00 : 1.00E 00 : 1.00E 00 3.00E 00 0.00E-01 : 9.00E 00:

ESE: 0.00E-01 : 1.00E 00 0.00E-01 : 0.00 E-01 : 2.00E 00 : 1.00E 00 : 4.00E 00:

SE : 3.00E 00 : 4.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01.s 0.00E-01 : 7.00E 00:

e -_____--. -_

l SSE: 4.00E 00 : 1.40E 01 : 4.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 2.6 0E 01:

S

1.00E 00 t 4.00E 00 2.00E 00 : 4.00E 00 : 1.00E 00 0.00E-01 : 1.20E 01:

__-----___--_-----.-_-_---____----------__--_.-_-_-___--------_---______---~~__-

l SSW: 0.00E-01 : 4.00E 00 6.00E 00 : 6.00E 00 : 1.10E 01 2.10E 01 : 4.80E 01:

SW : 0.00E-01 4.00E 00 : 5.00E 00 : 1.3 0E 01 : 1.50 E 01 : 9.00E 00 : 4.60E 01:

WSW: 1.00E 00 2.00E 00 : 1.00 E 01 : 6.00E 00 : 1.00E 00 : 0.00E-01 : 2.00E 01:

W s'O.00E-01 5.00E 00 : 1.40 E 01 : 4.00E 00 : 1.00E 00 0.00E-01 : 2.40E 01:

WNW: 0.00E-01 : 2.00E 00 : 1.10E 01 : 6.00E 00 : 1.00E 00 : 1.00E 00 : 2.10E 01:

NW 0.00E-01 : 3.00E 00 : 2.20E 01 3.00E 00 : 0.00E-01 : 0.00E-01 : 2.80E 01:

NNW: 1.00E 00 : 4.00E 00 : 1.30E 01 : 2.00E 00 : 1.00E 00 0.00E-01 2.10E 01:

TOT: 1.30E 01 : 7.50E 01 : 1.01E 02 : 5.90E 01 4.80E 01 : 3.40E 01 : 3.30E 02:

PERIOD 6 OF CALM (HOURS):

1.000E 00 HOURS OF INVALID DATA :

0.000E-01

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER #

1 REPORT START TIME

0:00 BRS = 12:00AM JANUARY 1,1986 REPORT END TIME
2159:59 BRS = 11:59PM MARCH 31, 1986 STABILITY CLASS
G ELEVATION 60 METERS WIND SPEED (MPH) AT 60 METER LEVEL 1-3 4-7 8-12 13-1 8 1 9-24

>24

TOTAL N
0.00E-01 : 2.005 00 : 3.005 00 7.00E 00 2.00E 00 : 0.00E-01 : 1.40E 01:

NNE:"0.00E-01 : 0.00E-01 : 2.00E 00 : 2.00E 00 0.00E-01 : 0.00 E-01 4.00E 00:

NE : 1.00E 00 5.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 7.00E 00:

ENE: 1.00E 00 : 2.00E 00 2.00E 00 2.00E 00 : 4.00E 00 0.00E-01 : 1.10E 01:

E

1.00E 00 0.00E-01 : 4.00E 00 2.00E 00 : 2.00E 00 0.00E-01 : 9.00E 00:

ESE: 2.00E 00 : 2.00E 00 : 6.00E 00 : 1.00E 00 : 1.00E 00 0.00E-01 : 1.20E 01:

SE s'2.00E 00 : 0.00 E-01 3.00E 00 : 0.00E-01 : 1.00E 00 2.00E 00 : 8.00E 00:

SSE: 2.00E 00 : 4.00E 00 3.00E 00 : 1.10E 01 : 2.00E 00 0.00E-01 : 2.20E 01:

S

2.00E 00 : 2.00E 00 : 4.00E 00 : 7.00E 00 9.00E 00 : 1.00E 00 : 2.50E 01:

SSW: 0.00 E-01 : 1.00E 00 : 1.00E 00 : 6.00E 00 : 8.00E 00 2.90E 01 : 4.50E 01:

SW : 1.00E 00 1.00E 00 : 5.00E 00 : 3.00E 00 : 4.00E 00 3.00E 00 : 1.7 0E 01:

WSW:'l.00E 00 0.00E-01 4.00E 00 : 4.00E 00 0.00E-01 : 0.0 0 E-01 : 9.00E 00:

W

1.00E 00 : 4.00E 00 2.00E 00 3.00E 00 : 0.00E-01 : 0.00 E-01 : 1.00E 01:

WNW: 0.00E-01 : 1.00E 00 : 8.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 1.00E 01:

NW 3.00E 00 : 1.00E 00 : 5.00E 00 : 2.00E 00 0.00E-01 : 0.00E-01 : 1.10E 01:

NNW: 0.00E-01 : 0.00 E-01 4.00E 00 : 3.00E 00 : 1.00E 00 : 0.00E-01 : 8.00E 00:

TOT: 1.7 0E 01 : 2.50E 01 : 5.70E 01 : 5.40E 01 3.40E 01 3.50E 01 : 2.22E 02:

PERIODS OF CALM (HOURS):

0.000E-01 HOURS OF INVALID DATA :

0.000R-01 HOURS OF GOOD DATA 2.0 94 E 03 =

96.9% OF TOTAL HOURS e

4

REPORT CATEGORY

NETEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RB00RD
QUARTER #

2 4

REPORT START TIME

2160: 00 HRS = 12:00AM APRIL 1,1986 REPORT END TIME
4343:59 HRS = 11:59PM JUNE 30, 1986 j

STABILITY CLASS

A ELEVATION 10 METERS WIND SPEED (MPHi AT 10 METER LEVEL 1-3 4-7 8-12 13-18 19-24

> 24

TOTAL j

N

0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.0 0 E-01 : 0.005-01 : 0.00E-01:

NNE8 0.00E-01 : 2.00E 00 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 0.005-01 : 3.00E 00:

NE : 0.00E-01 : 2.00E 00 3.00E 00 : 5.00E 00 0.00E-01 : 0.005-01 : 1.00E 01:

ENE: 0.00E-01 : 0.00E-01 : 2.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.00E 00:

E

0.00E-01 : 4.00E 00 3.00E 00 5.00E 00 0.00E-01 : 0.00E-01 : 1.20E 01:

ESEB 0.00E-01 : 3.00E 00 : 1.20E 01 2 3.00E 00 0.00E-01 : 0.00E-01 : 1.80E 01:~

SE : 0.00E-01 : 4.00E 00 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 7.00E 00:

4 SSE8 0.00E-01 : 2.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 2 3.00E 00:

S

0.00E-01 2 3.00E 00 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 5.00E 00s t

l SSW: 0.00E-01 : 4.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 4.00E 00:

SW 8 0.00E-01 : 4.00E 00 : 6.00E 00 : 5.00E 00 0.00E-01 : 0.00E-01 : 1.50E 01:

i WSW : 0.00E-01 : 4.00E 00 : 7.00E 00 0.00E-01 : 0.00E-01 1 0.00E-01 : 1.10E 01:

j W

0.00E-01 : 7.00E 00 : 4.00E 00 : 1.00E 00 0.00 E-01 : 0.00E-01 : 1.20E 01:

WNW8 0.00E-01 : 1.00E 00 : 5.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 1.00E 01:

NW 0.00E-01 : 0.00E-01 : 5.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 5.00E 00:

NNW8 0.00E-01 : 1.00E 00 2.00E 00 2.00E 00 : 0.00E-01 : 0.00E-01 : 5.'00E 00 :

TOT: 0.00E-01 : 4.10E 01 : 5.50E 01 : 2.60E 01 : 0.00E-01 : 0.00E-01 : 1.22E 02:

l PERIOD 6 OF CALM (HOURS):

0.000E-01

(

HOURS OF INVALID DATA :

0.000 E-01

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION

~ PERISD OF RECORD

QUARTER #

2 REPORT START TIME

216 0: 00 BRS = 12: 00AM APRIL 1, 1986 REPORT END TIME
4343:59 BRS = 11:59PM JUNE 30, 1996 STABILITY CLASS
B ELEVATION 10 METERS WIND SPEED (MPH) AT 10 METER LEVEL 4-7 8-12 13-1 8 19-24

>24

TOTAL

..__1-3 N

0.00E-01 : 0.00E-01 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.00E 00:

NNE: 0.00E-01 : 0.00E-01 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.00E 00:

NE : 0.00E-01 : 2.00E 00 1.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 4.00E 00:

ENE8 0.00E-01 : 2.00E 00 2.00E 00 3 0.00E-01 : 0.00E-01 : 0.00E-01 : 4.00E 00:

E

0.00E-01 3.00E 00 : 1.00E 00 : 4.00E 00 0.00E-01 : 0.00E-01 8.00E 00:

ESE: 0.00E-01 3.00E 00 2.00E 00 2.00E 00 : 0.00E-01 : 0.00E-01 : 7.00E 00 SE : 0.00E-01 : 1.00E 00 : 6.00E 00 : 0.00E-01 : 0.00E-01 0.00E-01 : 7.00E 00 SSE: 0.00E-01 : 3.00E 00 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 6.00E 00 S

0.00E-01 : 4.00E 00 2 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 4.00E 00:

SSW8'0.00E-01 : 2.00E 00 1.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 4.00E 00 SW 8 1.00E 00 0.00E-01 : 1.00E 00 3 2.00E 00 0.00E-01 : 0.00E-01 : 4.00E 00:

WSW8 0.00E-01 4.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 8.00E 00 s W

0.00E-01 : 0.00E-01 : 0.00E-01 : 2.00E 00 3.00E 00 : 0.00E-01 : 5.00E 00:

WNW: 0.00E-01 : 2.00E 00 3.00E 00 : 5.00E 00 1.00E 00 2 0.00 E-01 : 1.10E 01:

NW 0.00E-01 : 3.00E 00 : 3.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 7.00E 00:

NNW: 0.00E-01 : 2.00E 00 : 4.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 6.'00E 00 TOT: 1.00E 00 : 3.10E 01 2 3.50E 01 : 1.80E 01 : 4.00E 00 : 0.00E-01 : 8.90E 01:

PERIODS OF CALM (HOUPS):

0.000E-01 HOURS OF INVALID DATA :

0.000E-01 4

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 0 2

REPORT START TIME

' 2160: 00 BRS = 12: 00AM APRIL 1, 1986 REPORT END TIME
4343:59 BRS = 11:59PM JUNE 30, 1986 STABILITY CLASS
C ELEVATION 10 METERS WIND SPEED (MPH) AT 10 METER LEVEL 1-3 4 -7 8-12 13-18 19-24

>24

TOTAL i

N

0.00E-01 : 1.00E 00 3.00E 00 0.00E-01 : 0.00E-01 : 1.00E 00 5.00E 00:

NNE: 0.00E-01 : 0.00E-01 : 2.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 3.00E 00 i' NE

.0.00E-01 : 1.00E 00 : 3.00E 00 : 2.00E 00 0.00E-01 : 0.00E-01 : 6.00E 00:

l 1

4

- mEE: 0.00E-01 : 1.00E 00 5.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 6.00E 00:

E

0.00E-01 : 0.00E-01 : 1.00E 00 2 2.00E 00 : 0.00E-01 0.00E-01 : 3.00E 00:

ESE: 2.00E 00 : 0.00 E-01 : 7.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 1.00E 01:

t l

SE : 1.00E 00 : 7.00E 00 : 8.00E 00 0.00E-01 : 0.00E-01 : 0.00 E-01 : 1.6 0E 01:

SSE 0.00E-01 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00 E-01 : 2.00E 00 S

0.00E-01 : 2.00E 00 : 0.00E-01 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.00E 00:

SSW 0.00E-01 : 1.00E 00 : 4.00E 00 : 3.00E 00 0.00E-01 : 0.00E-01 8.00E 00:

^

SW : 0.00E-01 : 1.00E 00 : 4.00E 00 5.00E 00 : 0.00E-01 0.00E-01 : 1.00E 01:

WSW 0.00E-01 : 0.00E-01 : 5.00E 00 : 0.00E-01 : 0.00E-Ol : 0.00E-01 5.00E 003-l W

0.00E-01 : 5.00E 00 3.00E 00 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 1.00E 01:

l WNW: 1.00E 00 : 0.00E-01 : 2.00E 60 : 2.00E 00 : 1.00E 00 0.00E-01 : 6.00E 00:

NW 0.00E-01 : 3.00E 00 : 2.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 6.00E 00:

j NNW: 0.00E-01 : 1.00E 00 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 4.00E 00:

TOT: 4.00E 00 : 2.50E 01 : 5.20E 01 : 1.90E 01 : 1.00E 00 : 1.00E 00 : 1.02E 02:

i t

i PERIODS OF CALM (HOURS):

0.000E-01 i

HOURS OF INVALID DATA :

0.000E-01 i

1 i

i i

4 1

4~- m n ew,-,-.,,-

.n e,.~,----,-------.,-

_n.-,,_

1 REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 9 2

REPORT START TIME

216 0: 00 BRS = 12: 00 AM APRIL 1, 1986 REPORT END TIME
4343:59 BRS = 11:59PM JUNE 30, 1986 STABILITY CLASS
E ELEVATION 10 METERS WIND SPEED (MPB) AT 10 METER LEVEL 1-3 4 -7 8-12 13-18 19-24

>24

TOTAL N
3.00E 00 9.00E 00 1.10E 01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.30E 01:

NNE:'O.00E-01 : 2.50E 01 6.00E 00 0.00E-01 : 0.00E-01 : 3.10E 01:

-_0.00E-01 :

NE : 4.00E 00 : 1.50E 01 : 1.30E 01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 3.20E 01:

ENE: 1.00E 00 : 1.80E 01 : 1.6 0E 01 : 2.00E 00 : 0.00E-01 : 0.00E-01 3.70E 01:

E

2.00E 00 : 1.90E 01 : 2.30E 01 : 0.00E-01 : 2.00E 00 : 0.00E-01 : 4.6 0E 01:

ESE: 4.00E 00 : 2.60E 01 : 1.90E 01 : 0.00E-01 0.00E-01 : 0.00E-01 : 4.90E 01:

SE

~4.00E 00 1.40 E 01 : 2.20E 01 : 1.00E 00 0.00E-01 0.00E-01 : 4.10E 01:

SSE: 3.00E 00 : 1.00E 01 : 1.20E 01 : 3.00E 00 2 0.00E-01 : 0.00 E-01 2.80E 01:

S

2.00E 00 1.80E 01 : 1.00E 01 : 1.00E 00 0.00E-01 : 0.00E-01 : 3.10E 01:

SSW: 7.00E 00 : 3.30E 01 4.10E 01 : 9.00E 00 : 0.00E-01 : 0.00E-01 : 9.00E 01:

SW s'5.00E 00 2.40E 01 : 2.30E 01 : 7.00E 00 : 0.00E-01 : 0.00E-01 : 5.90E 01:

CSW:' l.00E 01 : 4.10E 01 : 8.00E 00 : 1.00E 00 : 0.00E-01 s.0.00E-01 : 6.00E 01:

W 6.00E 00 2.70E 01 6.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 2 3.90E 01:

WNW: 1.10E 01 : 2.40E 01 : 8.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 4.40E 01:

NW 9.00E 00 2.80E 01 : 1.6 0E 01 : 2.00E 00 0.00E-01 : 0.00E-01 : 5.50E 01:

~

NNW: 4.00E 00 : 1.20E 01 9.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 2.6 0E 01:

TOT: 7.50E 01 : 3.432 02 : 2.43E 02 : 2.80E 01 : 2.00E 00 0.00E-01 : 6.91E 02:

PERIODS OF CALM (BOURS):

0.000E-01 HOURS OF INVALID DATA :

0.000E-01

's

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 6 2

REPORT START TIME

2160: 00 BRS = 12: 00AM APRIL 1,1986 REPORT END TIME
4343:59 HRS = ll:59PM JUNE 30, 1986 STABILITY CLASS
D ELEVATION 10 METERS WIND SPEED (MPH) AT 10 METER LEVEL 1-3 4-7 8-12 13-16 19-24

>24

TOTAL N
1.00E 00 : 3.00E 00 2.20E 01 4.00E 00 0.00E-01 : 0.00E-01 : 3.00E 01:

f NNE: '0.00E-01 : 1.20E 01 : 2.90E 01 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 4.50E 01:

i. NE : 2.00E 00 : 1.50 E 01 5.80E 01 : 1.3 0E 01 : 0.00E-01 : 0.00E-01 : 8.80E 01:

i l

ENE: 1.00E 00 : 1.90E 01 : 4.10E 01 : 6.00E 00 0.00E-01 : 0.00E-01 : 6.7 0E 01:


~.--------------------------

E

3.00E 00 : 1.80E 01 : 2.80E 01 : 8.00E 00 3.00E 00 : 0.0 0 E-01' 6.00E 01:
l. --------------------------------------------------------------------------------

ESE: 2.00E 00 2.10E 01 : 1.7 0E 01 : 7.00E 00 0.00E-01 : 0.00 E-01 4.7 0E 01:

+


1:

SE : 2.00E 00 2.70E 01 : 2.10E 01 2 3.00E 00 0.00E-01 : 0.00E-01 : 5.30E 0


0E 01:

SSE: 3.00E 00 : 1.90E 01 : 1.80E 01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 4.0 i

S

1.00E 00 : 1.00E 01 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.50 E 01:

i SSW: 2.00E 00 : 8.00E 00 : 1.40 E 01 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 2.80E 01:

SW 3.00E 00 : 5.00E 00 : 1.40 E 01 : 8.00E 00 0.00E-01 : 0.00E-01 : 3.00E 01:

WSW: 8.00E 00 : 9.00E 00 2.10E 01 : 5.00E 00 : 1.00E 00 0.00 E-01 4.40E 01:

W s'9.00E 00 : 2.10E 01 : 1.7 0E 01 : 2.00E 00 0.00E-01 : 0.00E-01 : 4.90E 01:

WNW: 2.00E 00 : 2.00E 01 : 1.80E 01 : 7.00E 00 0.00E-01 : 0.00E-01 : 4.7 0E 01:

i NW 4.00E 00 2.10E 01 : 4.6 0E 01 : 4.00E 00 : 1.00E 00 0.00E-01 : 7.6 0E 01:

NNW: 1.00E 00 : 1.80E 01 : 2.40 E 01 : 2.00E 00 0.00E-01 : 1.00E 00 : 4.6 0E 01:

TOT: 4.40E 01 : 2.46E 02 : 3.92E 02 : 7.7 0E 01 : 5.00E 00 : 1.00E 00 7.65E 02:

PERIOD 6 OF CALM (HOURS):

0.000E-01 HOURS OF INVALID DATA :

1.000E 00

\\

l l

m...

i REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER #

2 REPORT START TIME

216 0:00 BRS = 12: 00AM APRIL 1,1986 i

REPORT END TIME

4343:59 BRS = ll:59PM JUNE 30, 1986 STABILITY CLASS
F ELEVATION 10 METERS WIND SPEED (MPB) AT 10 METER LEVEL 1-3 4 -7 8-12 13-18 19-24

>24

TOTAL N
1.00E 01 : 1.005 00 : 5.005 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 1.7 0E 01:

NNE: 1.00E 00 : 1.00E 00 : 0.00E-01 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.00E 00:

NE : 0. 00 E-0.1 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

ENE: 0.00E-01 : 2.00E 00 : 6.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 8.00E 00:

E

2.00E 00 8.00E 00 : 1.00E 01 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.003 01:

ESE: 1.00E 00 : 1.7 0E 01 : 6.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.40E 01:

SE : 1.00E 00 : 8.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.30E 01:

SSE: 0.00E-01 : 8.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.20E 01:

S

4.00E 00 : 9.00E 00 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.50E 01:

SSW:'7.00E 00 : 5.00E 00 : 1.6 0E 01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.80E 01:

SW : ~5.00E 00 2.00E 00 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 9.00E 00 WSW: 1.10E 01 : 1.00E 01 : 0.00E-01 : 0.00E-01 0.00E-01 : 0.00E-01 : 2.10E 01:

W

1.40E 01 : 9.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.30E 01:

WNW: 1.00E 01 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00 E-01 : 0.00E-01 : 1.30E 01:

NW 9.00E 00 : 1.00E 01 : 3.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.20E 01:

NNW: 6.00E 00 : 4.00E 00 0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 1.10E 01:

l TOT: 8.10E 01 : 9.70E 01 : 5.80E 01 : 2.00E 00 0.00E-01 : 0.00E-01 : 2.3 8E 02:

t PERIOD 6 OF CALM (BOURS):

1.000E 00 HOURS OF INVALID DATA :

0.000E-01

' REPORT CATEGORY

NETEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 4 2

REPORT START TIME

216 0:00 HRS = 12:00AM APRIL 1,1986 REPORT END TIME a 4343:59 HRS = ll:59PM JUNE 30, 1986 STABILITY CLASS
G ELEVATION 10 METERS WIND SPEED (MPH) AT 10 METER LEVEL 1-3 4-7 8-12 13-18 19-24

>24

TOTAL N
0.00E-01 : 0.00E-01 : 1.00E 00 2.00E 00 0.00E-01 : 0.00E-01 : 3.00E 00:

NNE: 0.00E-01 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

NE : 0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

ENE: 0.00E-01 3.00E 00 : 0.00E-01 0.00E-01 : 0.00E-01 : 0.00E-01 : 3.00E 00:

0.00E-01 : 7.00E 00 : 8.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.50E 01:

!.E___ __. _... __________

l ESE: 0.00E-01 : 1.50 E 01 : 9.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.40E 01:

l SE : 1.00E 00 : 9.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.10E 01:

l SSE: 0.00E-01 : 4.00E 00 : 4.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 8.00E 00:

l S

2.00E 00 3.00E 00 2.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 7.00E 00:

SSW: '2.00E 00 : 1.10E 01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1-40E 01:

SW 4.00E 00 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 6.00E 00:

WSN: 6.00E 00 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 9.00E 00:

W 4.00E 00 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 0.00E-01 : 7.00E 00:

WNW: 1.00E 01 : 5.00E 00 : 0.00E-01 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.5DE 01:

NW : 6.00E 00 : 0.00E-01 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 7.00E 00:

NNW: 3.00E 00 0.00E-01 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 4."00E 00:

TOT: 3.80E 01 : 6.7 0E 01 : 2.80E 01 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 1.35E 02:

i l

PERIOD 6 OF CALM (HOURS):

1.000E 00 HOURS OF INVALID DATA :

0.000E-01 1

HOURS OF GOOD DATA 2.144E 03 =

98.2% OF TOTAL HOURS I

1 i

l REPORT CATEGORY

NETEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT BACH WIND SPEED AND DIRECTION

PERIOD OF RECORD
QUARTER 9 2

REPORT START TIME

216 Os 00 BRS = 12: 00AM APRIL 1,1986 REPORT END TIME
4343:59 BRS = 11:59PM JUNE 30, 1986 STABILITY CLASS
A ELEVATION 60 METERS WIND SPEED (MPE) AT 60 METER LEVEL 1-3 4-7 8-12' 13-18 19-24

>24

TOTAL N
0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 0.00 E-01:

NNE:' O.00E-01 : 1.00E 00 s 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00 NE : 0.00E-01 : 2.00E 00 3.00E 00 : 1.00E 00 : 5.00E 00 0.00E-01 : 1.10E 01:

ENE: 0.00E-01 : 0.00 E-01 : 1.00E 00 : 1.00E 00 0.00E-01 : 0.00 E-01 2.00E 00:

E

0.00E-01 : 5.00E 00 : 3.00E 00 : 5.00E 00 3.00E 00 : 0.0 0 E-01 : 1.6 0E 01:

ESE: 0.00E-01 : 1.00E 00 7.00E 00 : 6.00E 00 : 1.00E 00 0.00E-01 : 1.50E 01:

SE : 2.00E 00 : 4.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 7.00E 00:

SSE: 0.00E-01 : 2.00E 00 : 0.00E-01 : 0.00 E-01 0.00 E-01 : 0.00 E-01 : 2.00E 00:

S

0.00E-01 : 1.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.00E 00:

SSW: 0.00E-01 : 2.00E 00 3.00E 00 : 0.00E-01 0.00E-01 : 0.00 E-01 5.00E 00 SW : 0.00E-01 : 0.00E-01 : 6.00E 00 : 4.00E 00 : 0.00E-01 : 2.00E 00 : 1.20E 01:

WSW: 0.00E-01 : 1.00E 00 : 5.00E 00 : 3.00E 00 : 2.00E 00 2.00E 00 : 1.30E Ol s '

W

0.00E-01 : 6.00E 00 2 5.00E 00 : 3.00E 00 2.00E 00 : 1.00E 00 : 1.70E 01:

WNW:'0.00E-01 0.00E-01 : 3.00E 00 : 0.00E-01 : 3.00E 00 : 1.00E 00 7.00E 00:

NW 0.00E-01 : 0.00E-01 : 7.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 7.00E 00:

NNW: 0.00E-01 : 1.00E 00 : 1.00E 00 3.00E 00 0.00E-01 : 0.00 E-01 5.D0E 00:

TOT: 2.00E 00 2.6 0E 01 4.60E 01 : 2.6 0E 01 : 1.60E 01 : 6.00E 00 : 1.22E 02:

PERIODS OF CALM (BOURS):

0.000E-01 HOURS OF INVALID DATA :

0.000E -

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

BACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 9 2

REPORT START TIME

2160:00 BRS = 12:00AM APRIL 1,1986 REPORT END TIME
4343:59 BRS = 11:59PM JUNE 30, 1986 STABILITY CLASS
B ELEVATION 60 METERS WIND SPEED (MPB) AT 60 METER LEVEL 1-3 4-7 8-12' 13-1 8 19-24

>24

TOTAL N
0.00E-01 : 0.00E-01 : 1.00E 00 s 0.00E-01 0.00E-01 : 0.00E-01 : 1.00E 00 NNE: '0.00E-01 : 0.00E-01 : 2.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 3.00E 00:

0.00E-01 : 1.00E 00

  • 2.00E 00 0.00E-01 : 0.00E-01 : 3.00E 00s NE'_s 0.00E-01 :

ENE: 0.00E-01 : 2.00E 00 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 5.00E 00:

E

0.00E-01 : 0.00h-01 2.00E 00 : 1.00E 00 : 4.00E 00 0.00E-01 : 7.00E 00:

ESE: 0.00E-01 : 3.00E 00 4.00E 00 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 9.00E 00:

SE

~0.00E-01 : 1.00E 00 : 5.00E 00 0.00E-01 : 0.00E-01 : 0.0 0 E-01 : 6.00E 00 SSE: 0.00E-01 : 5.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 0.00E-01 : 5.00E 00 S

0.00E-01 : 3.00E 00 0.00E-01 : 0.00E-01 : 0.00 E-01 0.00E-01 : 3.00E 00:

SSW: 0.00E-01 : 2.00E 00 0.00E-01 : 2.00E 00 0.00E-01 : 0.00E-01 : 4.00E 00:

SW : 0.00E-01 : 1.00E 00 : 1.00E 00 0.00E-01 : 0.00 E-01 : 1.00E 00 3.00E 00:

WSW: 1.00E 00 : 0.00E-01 : 2.00E 00 : 4.00E 00 2.00E 00 : 0.00E-01 9.00E 00:

W s'0.00E-01 : 1.00E 00 : 1.00E 00 : 0.00 E-01 0.00E-01 : 5.00E 00 7.00E 00:

WNW: 0.00E-01 : 2.00E 00 : 1.00E 00 1.00E 00 5.00E 00 2.00E 00 : 1.10E 01:

NW 0.00E-01 : 1.00E 00 6.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 8.00E 00:

NNW: 0.00E-01 : 0.00 E-01 2 3.00E 00 2.00E 00 0.00E-01 : 0.00E-01 5.V0E 00 TOT: 1.00E 00 2.10E 01 3.20E 01 : 1.6 0E 01 : 1.10E 01 : 8.00E 00 8.90E 01:

PERIODS OF CALM (HOURS):

0.000E-01 HOURS OF INVALID DATA :

0.000E-01 is

REPORT CATEGORY

METER 0 LOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 8 2

REPORT START TIME

2160:00 HRS = 12:00AM APRIL 1,1986

-REPORT END TIME

4343:59 BRS = 11:59PM JUNE 30, 1986 STABILITY CLASS
C LLEVATION 60 METERS WIND SPEED (MPH) AT 60 METER LEVEL s,

1-3 4-7 8-12 13-18 19-24

>24

TOTAL N
0.00E-01 : 1.00E 00 2.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 4.00E 00:

NNE: 0.00E-01 : 0.00E-01 : 0.00E-01 : 3.00E 00 : 1.00E 00 0.005-01 4.00E 00:

NE : 0.00E-01 : 0.00E-01 : 2.00E 00 2.00E 00 : 1.00E 00 : 0.00E-01 : 5.00E 00:

ENE: 0.00E-01 : 0.00E-01 a 3.00E 00

. 2.00E 00 : 0.00E-01 : 0.00E-01 : 5.00E 00:

E

0.00E-01 : 1.00E 00 : 1.00E 00 : 1.00E 00 : 3.00E 00 0.00E-01 6.00E 00:

ESE: 2.00E 00 : 2.00E 00 7.00E 00 4.00E 00 0.00E-01 : 0.00E-01 : 1.50E 01:

SE : 0.00E-01 : 3.00E 00 : 4.00E 00 0.00E-01 : 0.00E-01 0.00E-01 : 7.00E 00:

SSE: 0.00E-01 : 2.00E 00 1 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00 : 3.00E 00:

S

0.00E-01 : 0.00E-01 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00 SSW: 0.00E-01 : 0.00E-01 : 4.00E 00 2.00E 00 3.00E 00 0.00E-01 : 9.00E 00 SW :^0.00E-01 : 0.00E-01 : 1.00E 00 2.00E 00 : 4.00E 00 : 1.00E 00 : 8.00E 00:

WSW: 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.00E 00 : 3.00E 00 2.00E 00 : 7.00E 00:

W

0.00E-01 : 0.00E-01 : 5.00E 00 0.00E-01 : 5.00E 00 0.00E-01 : 1.00E 01:

WNW: 0.00E-01 : 1.00E 00 0.00E-01 : 2.00E 00 : 1.00E 00 : 2.00E 00 : 6.00E 00:

NW 0.00E-01 : 1.00E 00 : 3.00E 00 : 2.00E 00 : 1.00E 00 1 0.00E-01 : 7.00E 00:

NNW: 0.00E-01 : 1.00E 00 : 1.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 3.00E 00:

TOT: 2.00E 00 1.20E 01 2 3.40E 01 : 2.40E 01 : 2.20E 01 : 6.00E 00 : 1.00E 02:

PERIODS OF CALM (HOURS):

1.000E 00 HOURS OF INVALID DATA :

1.000E 00 1

t REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION

. PERIOD OF RECORD

QUARTER 4 2

REPORT START TIME

2160:00 BRS = 12:00AM APRIL 1,1986

-REPORT END TIME

4343:59 BRS = 11:59PM JUNE 30, 1986 STABILITY CLASS
D ELEVATION 60 METERS 1

i i

60 METER LEVEL l

WIND SPEED (MPB) AT l

1-3 4 '7 8-12' 13-1 8 19-24

>24

TOTAL N
0.00E-01.: 1.00E 00 : 6.00E 00 : 1.20E 01 : 0.00E-01 : 0.00E-01 : 1.90E 01:

NNE: 1.00E 00 : 2.005 00 : 1.90E 01 : 1.30E 01 : 5.00E 00 0.00E-01 4.00E 01:

NE : 1.00E 00 3.00E 00 : 2.90E 01 : 3.7 0E 01 : 4.00E 00 : 0.00E-01 : 7.40E 01:

ENE: 3.00E 00 : 8.00E 00 : 4.50E 01 3.30E 01 : 1.00E 00 0.005-01 : 9.00E 01:

E s ' 1.00E 00 : 9.00E 00 3.20E 01 : 1.80E 01 8.00E 00 : 5.00E 00 : 7.30E 01:

ESE: 2.00E 00 : 1.40E 01 : 2.50E 01 : 7.00E 00 2.00E 00 0.00E-01 5.00E 01:

\\

SE : 2.00E 00 : 1.70E 01 : 1.50E 01 : 7.00E 00 : 1.00E 00 : 0.00E-01 4.20E 01:

SSE: 2.00E 00 : 1.40E 01 : 8.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 2.50E 01:

S

~2.00E 00 : 7.00E 00 : 1.00E 01 : 1.00E 00 1 0.00E-01 : 0.00E-01 : 2.00E 01:

SSW 2.00E 00 : 7.00E 00 : 5.00E 00 : 7.00E 00 : 6.00E 00 0.00E-01 : 2.7 0E 01:

SW : 1.00E 00 2.00E 00 : 8.00E 00 : 1.10E 01 : 7.00E 00 2.00E 00 : 3.10E 01:

i WSN: 0.00E-01 : 9.00E 00 : 7.00E 00 : 1.20E 01 : 1.80E 01 : 5.00E 00 : 5.10 E 01 : '

i W

1.00E 00 : 8.00E 00 : 1.3 0E 01 : 1.10E 01 : 9.00E 00 0.00E-01 : 4.20E 01:

WNW: 1.00E 00 : 1.10E 01 : 1.40E 01 : 1.50 E 01 : 9.00E 00 3.00E 00 : 5.30E 01:

l NW : 0.00E-01 : 1.50 E 01 : 7.00E 00 : 4.20E 01 : 9.00E 00 : 1.00E 00 7.40E 01:

NNW: 0.00E-01 : 1.30E 01 : 1.90E 01 : 1.40E 01 : 2.00E 00 0.00E-01 : 4.80E 01:

TOT: 1.90E 01 : 1.4 0 E 02 : 2.6 2E 02 : 2.41E 02 : 8.10E 01 : 1.6 0E 01 : 7.59E 02:

PERIODS OF CALM (HOURS):

4.000E 00 HOURS OF INVALID DATA :

3.000E 00

__,,,..m,__wm_-w..

w,mp,..

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT EACH WIND SPEED AND DIRECTION PERI 8D OF RECORD

QUARTER #

2 REPORT START. TIME

2160:00 HRS = 12:00AM APRIL 1,1986 l

REPORT END TIME

4343:59 HRS = ll:59PM JUNE 30, 1986 STABILITY CLASS
E ELEVATION 60 METERS i

WIND SPEED (MPH) AT 60 METER LEVEL

..______-___>24 1-3 4-7 8-12 13-18 19-24

TOTAL N
1.00E 00 : 3.00E 00 7.00E 00 : 8.00E 00 : 0.00E-01 : 0.00E-01 : 1.90E 01:

l l

NNE: 1.00E 00 : 6.00E 00 : 1.4 0E 01 4.00E 00 0.00E-01 : 0.00E-01 : 2.50E 01:

NE :~0.00E-01 : 3.00E 00 2.60E 01 4.00E 00 0.00E-01 : 0.00 E-01 3.30E 01:

i ________________________ ___________________________________________________....

ENE: 1.00E 00 : 9.00E 00 : 1.6 0E 01 : 1.00E 01 : 0.00E-01 : 0.00E-01 3.6 0E 01:

i i

E a 0.00 E-01 : 9.00E 00 2.00E 01 : 2.60E 01 : 1.00E 00 2.00E 00 : 5.80E 01:

ESFs 2.00E 00 : 5.00E 00 : 9.00E 00 : 2.50E 01 : 4.00E 00 : 1.00E 00 : 4.60E 01:

_______... -_..... _________~.--

l SE : 2.00E 00 7.00E 00 : 1.20E 01 : 5.00E 00 : 5.00E 00 1.00E 00 : 3.20E 01:

SSE8 2.00E 00 : 1.20E 01 : 5.00E 00 8.00E 00 : 3.00E 00 0.00E-01 : 3.00E 01:

S

2.00E 00 3.00E 00 : 1.80E 01 : 8.00E 00 1.00E 00 : 1.00E 00 3.30E 01:

l SSW8 1.00E 00 5.00E 00 : 1.40E 01 : 2.50E 01 : 1.7 0E 01 : 2.00E 00 : 6.40E 01:

SW 0.00E-01 : 5.00E 00 2.00E 01 : 2.90E 01 : 1.30E 01 : 7.00E 00 : 7.40E 01:

WSW 0.00E-01 9.00E 00 2.70E 01 : 2.90E 01 : 5.00E 00 3.00E 00 7.30E 01:'

W

2.00E 00 3.00E 00 : 1.30E 01 : 2.40E 01 : 2.00E 00 0.00E-01 4.40E 01:

WNW8 ' l.00E 00 : 1.10E 01 : 2.00E 01 : 1.40E 01 : 4.00E 00 : 0.00 E-01 5.00E 01:

l NW s'2.00E 00 7.00E 00 : 7.00E 00 : 1.7 0E 01 : 2.00E 00 0.00E-01 3.50E 01:

i NNWe 1.00E 00 2.00E 00 : 1.40E 01 2.00E 01 : 0.00E-01 : 0.00E-01 : 3.70E Cl i

l TOT: 1.80E 01 : 9.90E 01 : 2.42E 02 : 2.56E 02 : 5.70E 01 1.7 0E 01 : 6.89E 02:

i

]

PERIODS OF CALM (HOURS):

1.000E 00 l

HOURS OF INVALID DATA :

1.000E 00 i

i t

i a

8 1

i I

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT 3

BACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER #

2 REPORT START TIME

2160:00 HRS = 12:00AM APRIL 1,1986 REPORT END TIME
4343:59 HRS = ll:59PM JUNE 30, 1986 i

STABILITY CLASS

F ELEVATION 60 METERS 4

4 WIND SPEED (MPU) AT 60 METER LEVEL i

1-3 4-7 8-12 13-18 19-24

>24

TOTAL N

2-0.00E-01 3.00E 00 : 2.00E 00 : 4.00E 00 : 1.00E 00 : 0.00E-01 : 1.00E 01:

i NNE ' l.00E 00 : 8.00E 00 4.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.3 0E 01:

NE : 0.00E-01 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.00E 00:

ENE: 3.00E 00 : 0.00 E-01 : 4.00E 00 1.00E 00 0.00E-01 : 0.00E-01 : 8.00E 00:

j E

2.00E 00 : 0.00E-01 : 4.00E 00 : 7.00E 00 3.00E 00 : 0.00E-01 : 1.6 0E 01:

ESE: 0.00 E-01 2 3.00E 00 : 5.00E 00 : 1.7 0E 01 3.00E 00 : 0.00E-01 : 2.80E 01:

SE : 0.00E-01 : 2.00E 00 : 1.00E 00 1.00E 00 : 0.00E-01 : 0.00E-01 4.00E 00:

SSE: 1.00E 00 2.00E 00 : 4.00E 00 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 1.00E 01:

f S

1.00E 00 : 1.00E 00 : 1.10E 01 : 4.00E 00 0.00E-01 : 0.00E-01 : 1.70E 01:

SSW 1.00E 00 : 1.00E 00 : 1.20R 01 : 4.00E 00 : 5.00E 00 2.00E 00 : 2.50E 01:

SW 2.00E 00 : 7.00E 00 : 5.00E 00 : 3.00E 00 : 9.00E 00 : 0.00E-01 : 2.6 0E 01:

WSW: 0.00E-01 : 1.00E 00 : 5.00E 00 : 2.00E 00 0.00E-01 : 0.00E-01 : 8.00E 00:

{

W

0.00E-01 3.00E 00 6.00E 00 : 7.00E 00 0.00E-01 : 0.00E-01 : 1.6 0E 01:

...._________________________~..._____________..____...._______________________

WNW: 1.00E 00 : 1.00E 01 : 5.00E 00 : 3.00E 00 0.00E-01 : 0.00E-01 : 1.90E 01:

NW 1.00E 00 : 3.00E 00 : 1.20E 01 8.00E 00 : 0.00E-01 : 0.00E-01 : 2.40E 01:

NNW: 0.00E-01 : 5.00E 00 : 5.00E 00 : 2.00E 00 1.00E 00 : 0.00E-01 : 1.3 0E 01:

i TOT: 1.30E 01 : 5.10E 01 : 8.50E 01 : 6.6 0E 01 : 2.20E 01 : 2.00E 00 2.39E 02:

l PERIODS OF CALM (HOURS):

0.000 E-01 i

HOURS OF INVALID DATA :

0.000E-01 a

I l

\\

4 l

l REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT l

EACH WIND SPEED AND DIRECTION l PERIOD OF RECORD
QUARTER #

2 REPORT START TIME

216 0:00 HRS = 12: 00AM APRIL 1,1986 REPORT END TIME
4343:59 HRS = 11:59PM JUNE 30, 1986 STABILITY CLASS
G ELEVATION 60 METERS i

WIND SPEED (MPH) AT 60 METER LEVEL 1-3 4-7 8-12' 13-18 39-24

>24

TOTAL D
0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00 2.00E 00 : 0.00E-01 3.00E 00:

NNE:'0.00E-01 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 0.00E-01 : 1.00E 00:

l NE : 0.00E-01 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

ENE: 0.00E-01 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

E

1.00E 00 : 2.00E 00 3.00E 00 : 4.00E 00 2.00E 00 : 4.00E 00 : 1.6 0E 01:

ESE: 0.00E-01 3.00E 00 2.00E 00 5.00E 00 : 6.00E 00 3.00E 00 : 1.90E 01:

SE : 0.00E-01 : 1.00E 00 2.00E 00 : 3.00E 00 1.00E 00 0.00E-01 : 7.00E 00 SSE: 0.00E-01 2.00E 00 : 3.00E 00 : 5.00E 00 0.00E-01 : 0.00E-01 : 1.00E 01:

S

0.00E-01 : 1.00E 00 : 5.00E 00 6.00E 00 : 1.00E 00 : 0.00E-01 : 1.30E 01 SSW 1.00E 00 : 2.00E 00 : 2.00E 00 : 7.00E 00 : 7.00E 00 0.00E-01 : 1.90E 01:

SW 0.00E-01 : 1.00E 00 2.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 4.00E 00 WSW 0.00E-01 : 1.00E 00 : 1.00E 00 : 3.00E 00 0.00E-01 : 0.00E-01 : 5.00E 00:

W s'l.00E 00 : 5.00E 00 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 7.00E 00 l

3.00E 00 : 6.00E 00 : 4.00E 00 : 2.00E 00 0.00E-01 : 0.00E-01 : 1.50E 01:

l W-_NW :

NW 1.00E 00 : 2.00E 00 : 5.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 9.00E 00 CNW: 1.00E 00 : 1.00E 00 : 1.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 4. DOE 00:

l i

TOT: 8.00E 00 : 2.90E 01 : 3.10E 01 : 4.00E 01 : 1.90E 01 7.00E 00 : 1.34E 02:

l PERIODS OF CALM (HOURS):

2.000E 00 HOURS OF INVALID DATA :

0.000E-01 l

HOURS OF GOOD DATA 2.140E 03 =

98.0% OF TOTAL HOURS l

1 I

g-REPORT CATEGORY.

NETEROLOGICAL' DATA.

QUARTERLY TOTALS OF HOURS AT

  • EACH WIND SPEED AMD DIRECTION l!

-PERIOD OF REOORD t QUARTER 4 3

i; REPORT START TIME

4344 : 00 HRS = 12: 00AM JULY 1, 1986 REPO3T END TIME
6551:59 HRS = ll:59PM SEPTEM ER 30, 1986 STABILITY CLASS
A ELEVATION 10 METERS a

6 e

WIND SPEED (MPH) AT 10 METER LEVEL s.

1-3 4-7 8-12 13-18 19-24

>24

TOTAL d

N

0.00E-01 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00 E-01. 1.00 E 00 :

NNE O.00E-01 : 1.00E 00 3.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 4.00E 00:

4 NE : 0.00E-01 : 8.00E 00 : 4.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.20 E 01.1 i

ENE: 0.00E-01 : 2.00E' 00 2.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 4.00E 00:

E

2.00E 00 5.00E 00 : 4.00E 00 : 0.00E-01 0.00E+01 : 0.00E-01's 1.10E 01:

~

~

~

~

~

~

~

~~~

~

~~

~

~~

~

~

555: 2IddE dd I"5 [db 5[ I"5 3db d[ I d 0dE-0[

5 055-d[ I 0!0dE d['I 2!6dE 0[I 5

f SE : 1.00E 00 : 1.40 E 01 : 3.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 1.90 E 012. 4, l

SSE: 0.00E 01 : 1.00E 01 : 0.00E 01 : 0.00E 01 : 0.00E 01 : 0.00E 01 : 1.00E 01:

I i

S

2.00E 00 : 2.50E 01 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.80E 01:

SSW: 4.00E 00 : 1.90E 01 : 1.6 0E 01 : 1.00E 00 0.00E 0.00E-01 : 4.00E Ole

____________________________-01 SW : 3.00E 00 : 1.20E 01 : 1.20E 01 : 0.00E-Ol': 0.00E-01 : 0.00 E-01 : 2.7 0E 01:

WSW 0.00E-01 : 1.50E 01 : 6.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.10E 01:

4 W

4.00E 00 : 1.7 0E 01 8.00E 00 : 0.00E-01 : 0.00E-01 : 0.00 E-01 : 2.90E 01:

1 WNW: 1.00E 00 : 1.30E 01 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.80E 01:, s NW 0.00E-01 : 8.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 0.00 E-01 : 1.20E 01:

NNW: 1.00E 00 : 3.00E 00 : 4.00E 00 0.00E-01 : 0.00E-01 0.00E-01 : 8.00E 00:

1 TOT: 2.00E 01 : 1.64E 02 : 8.40E 01 : 2.00E 00 : 0.00E-01 : 0.00 E-01 : 2.70E 02:

i PERIODS OF CALM (HOURS):

9.000E 00 l

HOURS OF INVALID DATA :

0.000E-01 4

f

(

i

(

i m-

___--w-..--,,%,_---

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF REOORD
QUARTER #

3 REPORT START TIME

4344:00 BRS = 12:00AM JULY 1,1986 REPORT END TIME
6551:59 BRS = ll:59PM SEPTEMBER 30, 1986 STABILITY CLASS
B ELEVATION 10 METERS l

WIND SPEED (MPH) AT 10 METER LEVEL 1-3 4-7 8-12 13-18 19-24

>24

TOTAL N
0.00E-01 : 1.00E 00 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 4.00E 00:

NNE: 0.00E-01 : 0.00E-01 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

NE : 1.00E 00 : 0.00E-01 6.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 7.00E 00 l

ENE: 1.00E 00 : 3.00E 00 : 3.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 7.00E 00:

i l

E s'1.00E 00 : 1.00E 00 1.00E 00 s 0.00E-01 : 0.00E-01 : 0.00E-01 : 3.00E 00:

l ESE: 0.00E-01 : 8.00E 00 : 3.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.10E 01:'

l SE : 0.00E-01 : 1.20E 01 : 6.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 1.90E 01:

l SSE: 0.00E-01 : 7.00E 00 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 9.00E 00:

S

1.00E 00 : 2.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 4.00E 00s SSW: 1.00E 00 : 8.00E 00 : 4.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.30E 01:

SW 0.00E-01 4.00E 00 : 6.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 01:

. WSW : 0.00E-01

  • 6.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 7.00E 00:

W 0.00 E-01 : 6.00E 00 : 5.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.10E 01:

WNW: 1.00E 00 : 1.3 0E 01 : 3.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.7 0E 01:

NW 1.00E 00 : 8.00E 00 : 2.00E 00 2 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.10E 01:

Nhh 0.00E-01 : 8.00E 00 5.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.'30E 01:

TOT: 7.00E 00 : 8.70E 01 : 5.20E 01 1.00E 00 : 0.00E-01 : 0.00E-01 : 1.47E 02:

PERIODS OF CALM (HOURS):

5.000E 00 HOURS OF INVALID DATA :

0.000E-01 l

l

~'*"'*N*-

= - - -

y -

l

)

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD'OF RECORD
QUARTER 9 3
4344:00 BRS = 12:00AM JULY 1,1986 l REPORT START TIME l REPORT END TIME
6551:59 HRS = ll:59PM SEPTEMBER 30, 1986 l STABILITY CLASS
C ELEVATION 10 METERS WIND SPEED (MPH) AT 10 METER LEVEL 13 4 -7 8-12 13-1 8 19-24

>24

TOTAL N
. l.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 2.00E 00:

NNE:'l.00E 00 : 3.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00 E-01 5.00E 00:

NE : 0.00E-01 : 3.00E 00 : 0.0 0 E-01 : 0.00E-01 : 0.00E-01 0.00E-01 : 3.00E 00:

ENE: 0.00 E-01 2.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 3.00E 002 E

0.00E-01 : 1.00E 00 : 1.00E 00 0.00E-01 0.00E-01 : 0.00E-01 : 2.00E 00:

ESE: 0.00 E-01 2 3.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 4.00E 00:

SE : 0.00E-01 : 7.00E 00 : 7.00E 00 : 0.00 E-01 0.00E-01 : 0.00E-01 : 1.40E 01:

SSE: 0.00E-01 : 3.00E 00 2.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 6.00E 00:~

S

1.00E 00 6.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 7.00E 00:

SSW 1.00E 00 6.00E 00 : 5.00E 00 3 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.20E 01:

SW 1.00E 00 : 3.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 8.00E 00:

WSW 1.00E 00 : 3.00E 00 : 2.00E 00 : 0.00 E-01 0.00E-01 : 0.00 E-01 6.00E 00:

W

0.00E-01 : 8.00E 00 3.00E 00 : 0.00E-01 : 0.00 E-01 : 0.00 E-01 : 1.10E 01:

l _.--__---_-_-_------_..__----_---_-__-_----------_---_-__---.......-_._-_-____

l WNW: 0.00E-01 5.00E 00 6.00E 00 0.00E-01 : 0.00 E-01 : 0.00E-01 : 1.10E 01:

______--_-__--_...-________----. _-_--_-___~_-__-_----_--__-_-_-_-------_-_-_-_.

t NW 1.00E 00 : 7.00E 00 : 2.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 01:

NNW: 1.00E 00 : 5.00E 00 : 4.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 01:

TOT: 8.00E 00 : 6.60E 01 : 3.90E 01 : 1.00E 00 : 0.00 E-01 : 0.00E-01 : 1.14E 02:

_.---____----_-...-______-_-_----__________-_-__~_. _--__--_---_-_-----_-_-__--

PERIODS OF CALM (HOURS):

7.000E 00 l

HOURS OF INVALID DATA :

0.000E-01


w-w-wyr w

y,--aw-y w

yw-w m

v


sw,wwmw-w

-g

,y

r

-REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF REOORD
QUARTER 4 3

REPORT START TIME

4344:00 HRS = 12:00AM JULY 1,1986 REPORT END TIME
6551:59 HRS = ll:59PM SEPTEMBER 30, 1986 STABILITY CLASS
D ELEVATION 10 METERS WIND SPEED (MPH) AT 10 METER LEVEL 1-3 4 :

8-12 13-18 19-24

>24

TOTAL N
1.00E 00 : 1.10E 01 : 6.00E 00 2.00E 00 0.00E-01 : 0.00E-01 : 2.00E 01:

WNE:' 0.00E-01 : 6.00E 00 : 3.00E 00 : 0.00E-01 : 0.00 E-01 0.00E-01 : 9.00E 00:

NE : 4.00E 00 : 1.30E 01 2.40E 01 : 4.00E 00 : 0.00E-01 : 0.00 E-01 : 4.50E 01:

l ENE: 0.00E-01 : 5.00E 00 : 1.3 0E 01 : 3.00E 00 0.00 E-01 : 0.00E-01 : 2.10E 01:

E

3.00E 00 : 1.6 0E 01 5.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.40E 01:

ESE: 6.00E 00 2.40E 01 : 1.7 0E 01 6.00E 00 0.00E-01 0.00E-01 : 5.30E 01:

SE s ' 4.00E 00 : 3.50E 01 3.80E 01 : 4.00E 00 0.00E-01 : 0.00E-01 : 8.10E 01:

SSE: 2.00E 00 : 2.80E 01 : 1.40E 01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 4.50E 01:

S

3.00E 00 : 1.10E 01 : 2.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 1.70E 01:

SSW: 4.00E 00 : 1.30E 01 : 2.6 0E 01 : 0.00E-01 : 0.00E-01 : 0.00 E-01 : 4.30E 01:

SW : 3.00E 00 : 1.20 E 01 : 1.00 E 01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.50E 01:

WSW: 2.00E 00 2.10E 01 : 4.00E 00 0.00E-01 : 0.00 E-01 : 0.00E-01 : 2.7 0E Ol s '

W

3.00E 00 2.00E 01 : 4.00E 00 0.00 E-01 : 0.00E-01 : 0.00E-01 : 2.7 0E 01:

l WNW: '6.00E 00 : 1.00E 01 : 7.00E 00 : 0.00 E-01 : 0.00E-01 : 0.00E-01 : 2.30E 01:

r NW 2.00E 00 : 1.60E 01 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.00E 01:

NNW: 2.00E 00 : 2.00E 01 : 3.00E 00 : 2.00E 00 : 0.00E-01 : 0.00E-01 2.7 0E 01:

TOT: 4.50E 01 : 2.61E 02 : 1.7 8E 02 : 2.30E 01 : 0.00E-01 : 0.00E-01 : 5.07E 02:

PERIODS OF CALM (HOURS):

1.600E 01 HOURS OF INVALID DATA :

0.000E-01

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION s QUARTER ~$

3 PERIOD OF RECORD RSPORT START TIME

4344:00 HRS = 12:00AM JULY 1,1986 REPORT END TIME
6551:59 BRS = ll:59PM SEPTEMBER 30, 1996 STABILITY CLASS
E ELEVATION 10 METERS WIND SPEED (MPH) AT 10 METER LEVEL 1-3 4-7 8-12' 13-18 19-24 t

>24

TOTAL N
9.00E 00 2.50E 01 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 3.50E 01:

NNEs# 6.00E 00 : 1.00E dl : 7.00E 00 0.00E-01 : 0.00 E-01 : 0.00E-01 : 2.30E 01:

NE : 3.002 00 : 1.10E 01 : 7.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.10E 01:

ENE: 1.00E 00

.1.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 3.00E 00:

i E

2.00E 00 : 1.20 E 01 5.00E 00 : 0.00E-01 : 0.00 E-01 : 0.00E-01 : 1.90E 01:

ESE: 3.00E 00 : 1.7 0E 01 : 4.00E 00 : 2.00E 00 0.00E-01 : 0.00E-01 : 2.6 0E 01:

)

SE : 5.00E 00 : 1.80E 01 : 3.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.6 0E 01:

SSE: 8.00E 00 : 1.80E 01 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.80E 01:

S

1.40E 01 4.10E 01 6.0CE 00 : 2.00E 00 0.00E-01 : 0.00E-01 : 6.30E 01:

SSK: 1.7 0E 01 : 5.40E 01 : 3.40E 01 : 6.00E 00 : 0.00E-01 : 0.00E-01 : 1.11E 02:

j SW 2.20E 01 : 4.6 0E 01 : 2.00E 01 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 9.00E 01:

______.--- __.....___ -________________.___.-__________----___..__- __________~

WSW '2.80E 01 : 2.50E 01 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 5.7 0E 01:

)

l W

2.50E 01 : 4.00E 01 3.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 6.80E 01:

1 WNW: 2.30E 01 : 1.6 0 E 01 : 3.00E 00 : 0.00E-01 : 0.00 E-01 : 0.00E-01 : 4.20E 01:

NW : 1.6 0E 01 : 3.30E 01 : 0.00 E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 4.90E 01:

NNW: 2.00E 01 : 2.20E 01 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 4.'40E 01:

TOT: 2.02E 02 : 3.89E 02 : 1.02E 02 : 1.20E 01 : 0.00E-01 : 0.00E-01 : 7.05E 02:

PERIODS OF CALM (BOURS):

2.600E 01 HOURS OF INVALID DATA :

0.000E-01

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER #

3 l

REPORT START TIME

4344:00 HRS = 12:00AM JULY 1,1986 REPORT END TIME
6551:59 HRS = ll:59PM SEPTEMBER 30, 1986 i

STABILITY CLASS

F ELEVATION 10 METERS 4

WIND SPEED (MPH) AT 10 METER LEVEL

--=________.....____________________________________________________.

a 1-3 4-7 8-12' 13-18 19-24

>24

TOTAL N
5.00E 00 : 1.00E 01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.50E 01:

__________________3._________________

NNE: 3.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 4.00E 00:

NE : 0.00E-01 : 0.00E-01 2 3.00E 00 : 0.00E-01 0.00E-01 0.00E-01 : 3.00E 00:

ENE: 0.00E-01 : 0.00E-01 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.00E 00:

l E

0.00E-01 : 0.00E-01 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

ESE: 4.00E 00 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 6.00E 00 SE : 2.00E 00 7.00E 00 1.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 1.10E 01:

i SSE: 8.00E 00 : 1.00 E 00 0.00E-01 : 0.00E-01 : 0.00 E-01 : 0.00E-01 : 9.00E 00:

S

6.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 7.00E 00:

SSW: 1.50E 01 6.00E 00 : 2.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.30E 01:

r SW 1.20E 01 : 2.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.40E 01:

WSW: 2.00E 01 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.30E 01:

W

2.4 0 E 01 : 1.40E 01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 3.80E 01:

l WNW: 4.50E 01 : 6.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 5.20E 01:

l NW 1.50E 01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.6 0E 01:

NNW: 1.00E 01 : 6.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1."6 0E 01:

TOT: 1.6 9E 02 : 6.00E 01 : 1.00E 01 : 1.00E 00 0.00E-01 : 0.00 E-01 2.40E 02:

i PERIODS OF CALM (HOURS):

7.000E 00 HOURS OF INVALID DATA :

0.000E-01

)

l

)

l t

.--n.,_--,,,-,,--..,,-,--,,--,,._,,,,,-,----,---m--

---.m,

.-,,m,,w._,.-,,-------,., -, - - - - -, - - - -, - - - - -, - - - - - - - - - - - - < - - - - - -

i e

l l

l REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT l

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD

QUARTER ~ #

3

-REPORT START TIME

4344:00 BRS = 12:00AM JULY 1,1986 REPORT END TIME
6551:59 HRS = ll:59PM SEPTEMBER 30, 1986 i

STABILITY CLASS

G ELEVATION 10 METERS l

WIND SPEED (MPH) AT 10 METER LEVEL l

1-3 4-7 8-12 13-18 1 9-24

>24

TOTAL I

t N

1.00E 01 : 2.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.20E 01:

NNE: 4.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 4.00E 00:

l l

l NE : 0.00 E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 0.00E-01 : 0.00E-01:

ENE: 0.00E-01 : 0.00E-01 : 0.00E-01 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

E

0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

1 l

ESE: 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00 s SE : 1.00E 00 : 2.00E 00 : 0.00 E-01 : 0.00 E-01 : 0.00E-01 : 0.00E-01 3.00E 00:

SSE: 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 0.00E-01 : 0.00E-01 : 1.00E 00:

1 S

0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

SSN: 2.00E 00 : 1.00E 00 : 0.00E-01 : 0.0 0 E-01 : 0.00E-01 : 0.00E-01 : 3.00E 00:

SW : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

)

WSW: 5.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00 E-01 5.00E 00:

W

1.40E 01 : 2.00E 00 : 0.00E-01 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.6 0E 01:

WNW: 2.10E 01 : 1.40 E 01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 3.50E 01:

NW : 1.60E 01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.6 0E 01:

NNW: 2.80E 01 : 1.00E 00 : 0.00E-01 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.30E 01:

TOT -1.04E 02 : 2.20E 01 : 0.00E-01 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.26E 02s j

PERIODS OF CALM (HOURS):

6.000E 00 HOURS OF INVALID DATA :

0.000E-01 HOURS OF GOOD DATA 2.185 E 03 =

99.0% OF TOTAL HOURS j

l I

l l

l

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACB WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 4 3

REPORT START TIME

4344:00 BRS = 12:00AM JULY 1,1986 REPORT END TIME
- 6551:59 HRS = ll:59PM SEPTEMBER 30, 1986 i

STABILITY CLASS

A ELEVATION 60 METERS WIND SPEED (MPE) AT 60 METER LEVEL 1-3 4-7 8-12 13-16 1 9-24

>24

TOTAL N
0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 0.00E-01 : 1.00E 00:

[

NNE: 0.00E-01 : 1.00E 00 : 1.00E 00 : 1.00E 00 : 0.002-01 0.00E-01 : 3.00E 00:

NE : 0.00E-01 : 2.00E 00 : 6.00E 00 : 1.00E 00 0.00 E-01 : 0.00E-01 : 9.00E 00:

l ENE: 1.00E 00 : 4.00E 00 5.00E 00 : 0.00 E-01 : 0.00E-01 : 0.00E-01 : 1.00E 01:

l E

0.00E-01 : 9.00E 00 : 5.00E 00 2.00E 00 : 0.00E-01 : 0.005-01 : 1.6 0E 01:

ESE: 2.00E 00 : 1.5 0 E 01 : 1.00E 01 : 6.00E 00 0.00E-01 : 0.00E-01 : 3.3 0E 01:

L SE : 0.00E-01 : 7.00E 00 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 01:

SSE: 0.00E-01 : 1.00E 01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 01:

f l

S

0.00E-01 : 8.00E 00 7.00E 00 0.00E-01 : 0.00E-01 : 0.00 E-01 : 1.50E 01:

SSW: 0.00E-01 : 1.40E 01 : 2.00E 01 : 8.00E 00 : 2.00E 00 : 1.00E 00 : 4.50E 01:

SW 2.00E 00 : 1.008 01 : 1.00R 01 : 6.00E 00 : 0.00E-01 : 0.00E-01 : 2.80E 01:

WSW: 0.00E-01 : 5.00E 00 : 8.00E 00 : 9.00E 00 : 0.00 E-01 : 0.00E-01 : 2.20E 01:'

W 1.00E 00 1.10E 01 : 1.10E 01 : 8.00E 00 0.00E-01 : 0.00 E-01 : 3.10E 01:

WNW ~ 1.00E 00 : 4.00E 00 : 1.20E 01 : 4.00E 00 : 0.00E-01 : 0.00 E-01 : 2.10E 01:

NW 0.00E-01 : 2.00E 00 : 1.20E 01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.40 E 01:

1 NNW: 1.00E 00 : 3.00E 00 : 6.00E 00 : 1.00E 00 : 0.00E-01 : 0.00 E-01 : 1.10E 01:

TOT: 4.00E 00 : 1.06 E 02 : 1.16 E 02 3 4.6 0E 01 : 2.00E 00 : 1.00E 00 : 2.79E 02:

i l

1 PERIODS OF CALM (HOURS):

0.000 E-01 HOURS OF INVALID DATA :

0.000E-01 1

l l

i REPORT CATEGORY

NETEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD QUARTER #

3 REPORT START TIME

4344:00 HRS = 12:00AM JULY 1,1986 REPORT END TIME
~6551:59 BRS = 11:59PM SEPTEMER 30, 1986 STABILITY CLASS
B ELEVATION 60 METERS WIND SPEED (MPH) AT 60 METER LEVEL a

1-3 4-7 8-12 13-18 19-24

>24

TOTAL N
0.00E-01 : 0.00E-01 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 2 3.00E 00:

NNE: 1.00E 00 : 0.00E-01 : 1.00E 02 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.00E 00:

t NE : 0.00E-01 : 0.00E-01 : 4.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 5.00E 00:

ENE: 0.00E-01 : 2.00E 00 : 5.00E 00 3 0.00E-01 : 0.00E-01 0.00E-01 : 7.00E 00:

E

1.00E 00 : 1.003 00 : 3.00E 00 : 0.00E-01 : 0.00E-01 0.00E-01 : 5.00E 00:

ESE: 0.00E-01 : 7.00E 00 : 4.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 1.20E 01:

SE : 1.00E 00 : 6.00E 00 : 5.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 1.30E 01:

SSE: 0.00E-01 : 7.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.10E 01:

l S

0.00E-01 : 2.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 6.00E 00:

SSW: 0.00E-01 : 0.00E-01 : 3.00E 00 : 2.00E 00 : 1.00E 00 : 0.00E-01 : 6.00E 00:

SW : 0.00E-01 : 2.00E 00 : 9.00E 00 7.00E 00 : 1.00E 00 : 0.00E-01 : 1.90E 01:

WSW: 0.00 E-01 : 1.00E 00 : 4.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 6.00E 00:

W

1.00E 00 : 1.00E 00 : 4.00E 00 : 6.00E 00 : 1.00E 00 : 0.00E-01 : 1.30E 01:

WNW: 0.00E-01 : 3.00E 00 : 1.10E 01 2.00E 00 0.00E-01 : 0.00E-01 : 1.60E 01:

NW : 0.00E-01 4.00E 00 : 7.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 1.20E 01:

_________________________________________________________________________'60E01:

NNW: 0.00E-01 : 4.00E '00 : 8.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 1.

TOT: 4.00E 00 : 4.00E 01 : 7.90E 01 : 2.6 0E 01 : 3.00E 00 : 0.00E-01 : 1.52E 02:

PERIODS OF CALM (HOURS):

0.000 E-01 HOURS OF INVALID DATA :

0.000E-01 I

i l

l

~,

REPORT CATEGORY

NETEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 6 3

REPORT START TIME

4344 : 00 HRS = 12: 00 AM JULY 1, 1986 i

REPORT END TIME

~ 6551:59 BRS = ll:59PM SEPTEMBER 30, 1986 STABILITY CLASS
C i

ELEVATION 60 METERS WIND SPEED (MPH) AT 60 METER LEVEL 1-3 4-7 8-12 13-18 19-24

>24

TOTP.L N
0.00E-01 : 1.00E 00 0.00E-61 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

NNE: 0.00E-01 : 3.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 4.00E 00:

NE : 0.00E-01 : 1.00E 00 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 3.00E 00:

ENE: 0.00E-01 : 2.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 3.00E 00:

l E

0.00E-01 : 0.00E-01 : 2.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 3.00E 00:

ESE: 0.00 E-01 3.00E 00 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 5.00E 00:

SE : 0.00E-01 : 5.00E 00 : 6.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 1.20E 01:

SSE: 0.00E-01 : 2.00E 00 : 4.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 7.00E 00 S

1.00E 00 : 3.00E 00 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 7.00E 00:

SSW: 0.00E-01 : 4.00E 00 : 2.00E 00 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 7.00E 00:

SW : 0.00E-01 : 1.00E 00 : 7.00E 00 : 6.00E 00 0.00E-01 : 1.00E 00 : 1.5 0 E 01:

WSW: 0.00E-01 : 3.00E 00 : 0.00E-01 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 5.00E 00: '

W

0.00E-01 : 0.00E-01 : 3.00E 00 : 7.00E 00 : 0.00E-01 : 0.00E-01 : 1.00E 01:

l WNW: 0.00E-01 : 4.00E 00 : 5.00E 00 : 5.00E 00 : 1.00E 00 : 0.00E-01 : 1.50 E 01:

l NN : 1.00E 00 : 1.00E 00 6.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 9.00E 00:

NNW: 1.00E 00 : 5.00E 00 : 7.00E 00 2.00E 00 : 0.00E-01 : 0.00E-01 : 1.30E 01:

TOT: 3.00E 00 : 3.80E 01 : 5.10E 01 : 2.6 0E 01 : 2.00E 00 : 1.00E 00 : 1.21E 02:

PERIODS OF CALM (HOURS):

0.000E-01 HOURS OF INVALID DATA :

0.000E-01

I 1

l REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER #

3 REPORT START TIME

4344:00 BRS = 12:00AM JULY 1,1986 REPORT END TIME s'6551:59 HRS = ll:59PM SEPTEM ER 30, 1986 STABILITY CLASS
D ELEVATION 60 METERS WIND SPEED (MPH) AT 60 METER LEVEL 1-3 4-7 8-12 13-10 19-24

>24

TOTAL N
2.00E 00 : 4.00E 00 : 9.00E 00 2.00E 00 : 1.00E 00 : 1.00E 00 : 1.90E 01:

l l

NNE: 1.00E 00 : 0.00E-01 : 7.00E 00 : 2.00E 00 0.00E-01 : 0.00E-01 : 1.00E 01:

NE : 1.00E 00 : 5.00E 00 : 1.20E 01 : 1.00E 01 1.00E 00 0.00E-01 : 2.90E 01:

ENE: 2.00E 00 : 6.00E 00 : 1.60E 01 : 1.20E 01 : 1.00E 00 : 0.00E-01 : 3.7 0E 01:

E

2.00E 00 : 8.00E 00 : 9.00E 00 : 7.00E 00 0.00E-01 : 0.00E-01 : 2.6 0E 01:

ESE: 2.00E 00 : 1.5 0 E 01 : 2.6 0E 01 : 1.90E 01 : 4.00E 00 0.00E-01 : 6.6 0E 01:

SE : 2.00E 00 : 1.80E 01 2.30E 01 : 1.6 0E 01 : 0.00E-01 : 0.00E-01 : 5.90E 01:

SSE: 5.00E 00 : 2.30E 01 : 2.20E 01 : 4.00E 00 : 0.00E-01 : 0.00E-01 5.40E 01:

S

1.00E 00 : 8.00E 00 : 9.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 1.90E 01:

l SSW: 0.00E-01 : 2.00E 00 9.00E 00 : 2.00E 01 : 3.00E 00 : 1.00E 00 2 3.50E 01:

SW 1.00E 00 : 7.00E 00 : 1.50 E 01 1.00E 01 : 7.00E 00 : 0.00E-01 : 4.00E 01:

WSW 0.00E-01 : 3.00E 00 : 8.00E 00 : 1.20E 01 : 0.00E-01 : 0.00E-01 : 2.30E 01:

W 0.00E-01 6.00E 00 : 1.10E 01 : 1.4 0 E 01 : 1.00E 00 : 0.00E-01 : 3.20E 01:

WNW: 0.00E-01 : 8.00E 00 : 1.3 0E 01 3.00E 00 : 7.00E 00 : 0.00E-01 : 3.10E 01:

NW 0.00E-01 : 6.00E 00 6.00E 00 : 3.00E 00 : 1.00E 00 : 0.00E-01 : 1.6 0E 01:

~

NNW: 0.00E-01 : 4.00E 00 : 1.7 0E 01 : 4.00E 00 : 2.00E 00 : 0.00E-01 : 2.7 0E 01:

TOT: 1.90E 01 : 1.23E 02 : 2.12E 02 : 1.3 0E 02 : 2.80E 01 : 2.00E 00 : 5.23E 02:

1 l

PERIODS OF CALM (BOURS):

U.000E-01 HOURS ~OF INVALID DATA :

0.000E-01 l

6

_-_-...--.,_.-.__.,__,-_n

-_.-..._._-....v,

~.. -

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 4 3

REPORT START TIME

4344 : 00 BRS = 12: 00 AM JULY 1, 1986 REPORT END TIME s' 6551:59 HRS = 11:59PM SEPTEMBER 30, 1986 STABIt.ITY CLASS
E ELEVATION 60 METERS WIND SPEED (MPH) AT 60 METER LEVEL t

s 1-3 4-7 8-12 13-18 1 9-24

>24

TOTAL i

N

1.00E 00 : 1.00E 01 : 1.20E 01 : 6.00E 00 2 0.00E-01 : 0.00E-01 : 2.90E 01:

NNE: 2.00E 00 : 7.00E 00 : 1.60E 01 : 1.20E 01 : 0.00E-01 : 0.00E-01 : 3.70E 01:

NE : 2.00E 00 : 8.00E 00 : 1.00E 01 3.00E 00 : 0.00E-01 : 0.00E-01 :' 2.30E 01:

ENE: 2.00E 00 : 6.00E 00 : 2.00E 00 : 3.00E 00 0.00E-01 : 0.00E-01 : 1.3 0E 01:

E

1.00E CO : 4.00E 00 : 1.20E 01 : 5.00E 00 : 0.00E-01 : 0.00E-01 : 2.20E 01:

ESE: 1.00E 00 : 5.00E 00 : 1.00E 01 : 7.00E 00 : 2.00E 00 : 0.00E-01 : 2.50E 01:

SE : 1.00E 00 : 7.00E 00 : 1.40E 01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 2.3 0E 01:

SSE: 1.00E 00 2.10E 01 : 1.20E 01 : 1.00E 00 0.00E-01 : 0.00E-01 : 3.50E 01:

S

1.00E 00 : 1.00E 01 : 2.50E 01 : 8.00E 00 : 1.00E 00 : 0.00E-01 : 4.50E 01:

i SSW: 1.00E 00 : 1.10E 01 : 3.10E 01 : 3.20E 01 : 8.00E 00 : 1.20E 01 : 9.50E 01:

SW 0.00E-01 : 5.00E 00 : 4.80E 01 : 4.40E 01 : 1.20E 01 : 9.00E 00 : 1.18E 02:

WSW: 2.00E 00 : 8.00E 00 : 3.10E 01 : 1.90E 01 : 2.00E 00 : 0.00E-01 : 6.20E 01:

l W

3.00E 00 : 6.00E 00 3.30E 01 : 2.40E 01 : 1.00E 00 : 0.00E-01 : 6.7 0E 01:

l, l

WNW: 1.00E 00 : 8.00E 00 : 2.40E 01 1.50E 01 : 1.00E 00 : 0.00E-01 : 4.90E 01:

l NW 3.00E 00 : 1.20E 01 : 2.40E 01 : 6.00E 00 : 0.00E-01 : 0.00E-01 : 4.50E 01:

l

~

NNW: 2.00E 00 : 7.00E 00 : 2.30E 01 : 1.10E 01 : 0.00E-01 : 0.00E-01 4.30E 01:

l l

TOT: 2.4 0 E 01 : 1.35E 02 : 3.27E 02 : 1.97E 02 : 2.70E 01 : 2.10E 01 : 7.31E 02:

PERIODS OF CALM (HOURS):

0.000E-01 HOURS OF INVALID DATA :

0.000E-01

__.-_..__,-----,----,.,,--.--...-.in------

--.-,--,--,vry.,ym,w

--.--e--w.-

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 4 3

REPORT START TIME

4344 : 00 HRS = 12: 00 AM JULY 1, 1986 REPORT END TIME
- 6551:59 BRS = 11:59PM SEPTEMBER 30, 1986 STABILITY CLASS
F l

ELEVATION 60 METERS WIND SPEED (MPH) AT 60 METER LEVEL 1-3 4-7 8-12 13-18 19-24

>24

TOTAL l

!N

0.00E-01 : 2.00E 00 : 5.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 8.00E 00:

NNE: 0.00E-01 : 4.00E 00 5.00E 00 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 1.20E 01:

NE : 1.00E 00 : 5.00E 00 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 9.00E 00:

ENE: 0.00E-01 6.00E 00 : 1.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 1.10E 01:

E

0.00 E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 1.00E 00:

ESE: 0.00E-01 : 3.00E 00 : 0.00E-01 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 4.00E 00:

SE : ~0.00E-01 : 7.90E 00 : 4.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 1.20E 01:

SSE: 4.00E 00 : 9.00E 00 : 2.00E 00 : 0.00 E-01 : 0.00E-01 : 0.00E-01 : 1.50E 01:

S

0.00E-01 : 5.00E 00 2.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 8.00E 00:

SSW: 2.00E 00 : 6.00E 00 : 4.00E 00 : 2.00E 00 : 1.00E 00 : 1.00E 00 : 1.6 0E 01:

SW : 1.00E 00 : 6.00E 00 2.10E 01 : 5.00E 00 : 0.00E-01 : 0.00E-01 : 3.30E 01:

WSW: 1.00E 00 : 3.00E 00 : 8.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 1.3 0E 01:

W 2.00E 00 : 1.00E 00 : 5.00E 00 : 7.00E 00 : 0.00E-01 : 0.00E-01 : 1.50E 01:

l WNW: 0.00 E-01 2 8.00E 00 : 2.50E 01 : 2.20E 01 : 0.00E-01 : 0.00E-01 : 5.50E 01:

1 NW 0.00E-01 : 2.00E 00 : 1.90E 01 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 2.40E 01:

t NNW: 1.00E 00 : 4.00E 00 : 5.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 1.10E 01:

TOT: 1.20E 01 : 6.90E 01 : 1.09E 02 5.50E 01 : 1.00E 00 : 1.00E 00 : 2.47E 02:

l PERIODS OF CALM (HOURS):

0.000E-01 I

HOURS OF INVALID DATA :

0.000E-01 l

l l

l

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 4 3

4344:00 HRS = 12:00AM JULY 1,1986 REPORT START TIME REPORT END TIME

6551:59 HRS = ll:59PM SEPTEM ER 30, 1986 STABILITY CLASS
G ELEVATION 60 METERS WIND SPEED (MPH) AT 60 METER LEVEL 1-3 4-7 8-12 13-18 19-24

>24

TOTAL N

s'O.00E-01 : 1.00E 00 : 3.00E 00 0.00E-01 0.00E-01 : 0.00E-01 : 4.00E 00:

NNE: 0.00E-01 : 1.00E 00 : 1.00E 00 : 0.00E-01 0.00E-01 0.00E-01 : 2.00E 00:

NE 1.00E 00 : 9.00E 00 : 1.00E 00 : 0.00E-01 0.00E-01 : 0.00E-01 : 1.10E 01:

......-------_-------------------------------------_--- 1 : 0.00E-01 : 9.00E 00:

ENE: 3.00E 00 6.00E 00 : 0.00E-01 : 0.00E-01 : 0.00 E-0 E

2.00E 00 : 6.00E 00 : 0.00E-01 : 0.00 E-01 : 0.00E-01 : 0.00 E-01 : 8.00E 00:

_---0.00E-01 : 0.00E-01 : 1.00E 01:

ESE: 2.00E 00 : 8.00E 00 : 0.00E-01 : 0.00E-01 :


0.00E-01 : 0.00E-01 : 1.00E 00:

SE : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 :

SSE: 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:


...---------------------------------------~~------------ -

S

0.00E-01 : 2.00E 00 2.00E 00 : 0.00E-01 : 0.00 E-01 0.00E-01 : 4.00E 00:

SSW: 1.00E 00 : 6.00E 00 2.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 1.00E 01:

SW 2.00E 00 : 5.00E 00 : 7.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.4 0 E 01:

1.00E 00 : 3.00E 00 : 4.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 9.00E 00:

l WSW:

1.00E 00 : 5.00E 00 : 1.00E 00 : 1.00E 00 : 0.00E-01 : 0.00 E-01 : 8.00E 00:

W----...--..------------

WNW: 2.00E 00 : 1.00E 00 : 1.00E 01 4.00E 00 : 0.00E-01 : 0.00E-01 : 1.7 0E 01:

NW 1.00E 00 : 8.008 00 : 5.00E 00 : 5.00E 00 : 0.00E-01 : 0.00 E-01 : 1.90E 01:

NNW: 0.00E-01 : 2.00E 00 : 3.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 6.00E 00:

TOT: 1.7 0E 01 : 6.30E 01 : 3.90E 01 : 1.30E 01 : 0.00E-01 : 0.00E-01 : 1.32E 02:

PERIODS OF CALM (HOURS):

0.000E-01 HOURS OF INVALID DATA :

0.000E-01 HOURS OF GOOD DATA 2.185 E 03 =

99.0% OF TOTAL HOURS mra

-REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER #

4 REPORT START TIME

6552 : 00 HRS = 12: 00AM OCTOB ER 1, 1986

' REPORT END TIME

8698: 00 HRS = 10 : 00 AM DECEMBER 29, 1986 STABILITY CLASS
A ELEVATION 10 METERS WIND SPEED (MPH) AT 10 METER LEVEL 1-3 4-7 8-12 13-18 19-24

>24

TOTAL N
1.00E 00 2.00E 00 : 4.00E 80 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 7.00E 00:

NNE: 1.00E 00 : 2.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 7.00E 00:

NE : 0.00E-01 : 4.00E 00 : 6.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 01:

ENE: 1.00E 00 : 2'.00 E 0 0 ' : 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 5.00E 00:

E r l.00E 00 : 1.00E 00 : 4.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 7.00E 00:

ESE: 0.00E-01 : 1.00E 00 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 3.00E 00:

SE : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:.

SSE: 0.00E-01 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:~

S

4.00E 00 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 7.00E 00:

SSW 5.00E 00 : 1.40E 01 : 1.10E 01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 3.10E 01:

SW s'3.00E 00 : 1.4 0 E 01 : 3.00E 01 : 7.00E 00 : 0.00E-01 : 0.00E-01 : 5.40E 01:

WSW: 3.00E 00 : 1.00E 01 : 1.50E 01 : 5.00E 00 : 0.00E-01 : 0.00E-01 : 3.30E 01:.

W 2.00E 00 : 1.20E 01 : 5.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 2.30E 01:

WNW: 0.00E-01 : 4.00E 00 : 6.00E 00 : 1.00E 00 : 0.00 E-01 : 0.00E-01 : 1.10E 01:

l#f : 2.00E 00 : 8.00E 00 : 8.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.80E 01:

NNW: 0.00E-01 0.00E-01 3.00E 00 : 0.00 E-01 : 0.0 0 E-01 : 0.00E-01 : 3.~0 0 E 00 :

TOT: 2.30E 01 : 7.80E 01 : 1.00E 02 : 1.90E 01 : 0.00E-01 : 0.00E-01 : 2.20E 02:

PERIODS OF CALM (BOURS):

0.000 E-01 i

HOURS OF INVALID DATA :

0.000E-01 e

I

~

_n,--.n,,.

l REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 4 4

l REPORT START TIME

6552:00 HRS = 12:00AM OCTOBER 1,1986 REPORT END TIME
-86 98:00 HRS = 10: 00AM DECEDBER 29, 1986 STABILITY CLASS
B ELEVATION 10 METERS i

WIND SPEED (MPH) AT 10 METER LEVEL 1-3 4 -7 8-12 13-18 19-24

>24

TOTAL N
0.00E-01 : 0.00E-01 1.00E 00 : 2.00E 00 0.00E-01 : 0.00E-01 : 3.00E 00:

1 NNE: 0.00E-01 : 0.00E-01 : 0.00 E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

NE : 0.00E-01 : 2.00E 00 : 5.00E 00 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 1.00E 01:

ENE: 0.00E-01 : 0.00E-01 : 1.00E 00 : 3.00E 00 : 1.00E 00 : 0.00E-01 : 5.00E 00 E

1.00E 00 : 1.00E 00 : 0.00E-01 : 1.00E 00 : 3.00E 00 : 0.00E-01 : 6.00E 00:

ESE: 0.00E-01 : 0.00E-01 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

l SE : 0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

SSE: 0.00 E-01 : 0.00E-01 : 2.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 3.00E 00:

l S

1.00E 00 : 6.00E 00 0.00 E-01 : 0.00E-01 : 0.00E-01 0.00E-01 : 7.00E 00:

l SSW: 2.00E 00 : 6.00E 00 : 4.00E 00 : 0.00 E-01 : 0.00E-01 : 0.00E-01 : 1.20E 01:

SW 4.00E 00 : 8.00E 00 : 1.10E 01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.30E 01:

WSW 2.00E 00 : 1.00E 01 : 8.00E 00 : 0.00E-01 0.00E-01 : 0.00E-01 : 2.00E 01:~.i W

3.00E 00 : 8.00E 00 : 7.00E 00 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 2.00E 01:

WNW: 4.00E 00 3.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 8.00E 00s NW : 1.00E 00 : 2.00E 00 : 1.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 5.00E 00:

i j

NNW: 0.00E-01 : 3.00E 00 0.00 E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 3.00E 00:

TOT: 1.80E 01 5.00E 01 : 4.20E 01 : 1.3 0 E 01 : 4.00E 00 : 0.00E-01 : 1.27E 02:

l l

1 PERIODS OF CALM (HOURS):

0.000E-01 l

HOURS OF INVALID DATA :

0.000E-01 1

1

_.._.._._..,I

i REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 6 4

REPORT START TIME

6552 : 00 HRS = 12: 00AM OCTOBER 1, 1986 REPORT END TIME
'86 98: 00 BRS = 10 : 00 AM DECEMBER 29, 1986 l

STABILITY CLASS

C l

ELEVATION 10 METEES WIND SPEED (MPH) AT 10 METER LEVEL 1-3 4 -7 8-12 13-18 19-24

>24

TOTAL N
0.00E-01 : 0.00E-01 : 3.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 7.00E 00:

1 NNE: 2.00E 00 : 0.00 E-01 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 4.00E 00:

1 i

NE : 0.00E-01 : 0.00E-01 : 8.00E 00 : 7.00E 00 : 5.00E 00 : 0.00E-01 : 2.00E 01:

1 ENE: 1.00E 00 : 3.00E 00 : 2.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 6.00E 00:

_________-______________________________ _______________________ ___________~_..

E

0.00E-01 : 2.00E 00 : 1.00E 00 : 0.00E-01 : 5.00E 00 : 0.00E-01 : 8.00E 00:

ESE: 1.00E 00 : 6.00E 00 2.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 1.00E 01:

SE : 1.00E 00 : 4.00E 00 : 2.00E 00 : 4.00E 00 : 1.00E 00 : 0.00E-01 : 1.20E 01:

SSE: 1.00E 00 : 1.00E 00 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 0,00E-01 2 3.00E 00:

S

1.00E 00 : 3.00E 00 : 1.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 6.00E 00:

\\

SSW: 3.00E 00 : 4.00E 00 : 5.00E 00 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 1.4 0 E 01:

SW 2.00E 00 : 2.30E 01 : 2.30E 01 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 5.20E 01:

WSW: 0.00E-01 : 1.90E 01 : 1.4 0 E 01 : 8.00E 00 : 0.00E-01 : 0.00E-01 : 4.10E 01:

W

4.00E 00 : 7.00E 00 : 8.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 2.30E 01:

WNW: 2.00E 00 : 4.00E 00 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 9.00E 00:

\\ _____________ ___.__-__ ______________...______________._____________-________.

l NW 0.00E-01 : 1.00E 00 : 1.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 3.00E 00:

i ________________________________________________________________________________

NNW: 2.00E 00 : 1.00E 00 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 6.00E 00:

l __..____.-_______ __________ __

TOT: 2.00E 01 : 7.80E 01 : 7.80E 01 3.70E 01 : 1.10E 01 : 0.00E-01 : 2.24E 02:

PERIODS OF CALM (HOURS):

1.000E 00 l

HOURS OF INVALID DATA :

0.000E-01 1

i l

l l

l l

l l

i i,.-,i.----.,.-

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT EACH WIND SPEED AND DIRECTION PERIOD OF RECORD

QUARTER 4 4

- REPORT START TIME

6552:00 HRS = 12:00AM OCTOBER 1,1986 REPORT END TIME
  • 8698:00 HRS = 10: 00AM DECEMBER 29, 1986 STABILITY CLASS
D ELEVATION 10 METERS WIND SPEED (MPH) AT 10 METER LEVEL 1-3 4 -7 8-12 13-18 19-24

>24

TOTAL N
5.00E 00 : 7.00E 00 5.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.70E 01:

NNE: 3.00E 00 : 9.00E 00 : 1.3 0E 01 : 1.00E 00 0.00E-01 : 0.00E-01 : 2.6 0E 01:

NE : 1.00E 00 : 1.7 0E 01 3.70E 1: 1.20E 01 : 2.00E 00 0.00E-01 : 6.90E 01:

RNE: 0.00E-01 : 5.00E 00 2.40E 01 : 4.00E 00 0.00E-01 : 0.00E-01 : 3.30E 01:

E -: 1.00E 00 : 2.00E 00 : 8.00E 00 : 2.00E 00 1.00E 00 : 0.00E-01 : 1.4 0 E 01:

ESE: 4.00E 00 : 8.00E 00 2.00E 00 : 6.00E 00 : 3.00E 00 0.00E-01 : 2.30E 01:

SE : 2.00E 00 : 1.80E 01 : 1.00E 01 : 7.00E 00 : 1.00E 00 : 0.00E-01 : 3.80E 01:

SSE: 5.00E 00 : 1.5 0E 01 : 5.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.50E 01:

S

1.00E 01 : 3.00E 01 : 5.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 4.50E 01:

SSW: 6.00E 00 : 3.80E 01 : 2.70E 01 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 7.30E 01:

SW 1.80E 01 : 5.70E 01 : 5.00E 01 : 5.00E 00 : 0.00E-01 : 0.00E-01 : 1.30E 02:

WSW: 2.30E 01 : 5.30E 01 : 3.50E 01 : 2.00E 00 0.00E-01 : 0.00 E-01 : 1.13 E 02:

W

~2.90E 01 : 3.30E 01 : 2.80E 01 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 9.40E 01:

WNW: 1.6 0E 01 : 3.50E 01 : 7.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 5.90E 01:

NW 9.00E 00 : 9.00E 00 : 5.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.30E 01:

NNW: 9.00E 00 : 1.30E 01 : 8.00E 00 : 0.0 0 E-01 : 0.00E-01 : 0.00 E-01 : 3.'00E 01:

TOT: 1.41E 02 : 3.49E 02 : 2.69E 02 4.60E 01 : 7.00E 00 : 0.00E-01 : 8.12E 02:

t PERIODS OF CALM (HOURS):

7.000E 00 HOURS OF INVALID DATA :

0.000E-01

-,----,,m-.,---

.,y,,,_m


mm,--


,----,,,c,-

g,----

1

.-----e.,

n_-m._,,.,,,,,_nw

-.a.m.,.,,,,n--_

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION i

PERIOD OF RECORD

QUARTER #

4 REPORT START TIME

6552: 00 HRS = 12: 00AM OCTOBER 1,.1986 REPORT END TIME
86 98: 00 HRS = 10: 00AM DECEMBER 29, 1986 STABILITY CLASS
E ELEVATION 10 METERS WIND SPEED (mph) AT 10 HETER LEVEL 1-3 4-7 8-12 13-1 8 19-24

>24

TOTAL i

N

1.00E 01 : 9.00E 00 : 2.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 2.20E 01:

'NNEs 1.00E 00 : 6.00E 00 3.00E 00 : 3.00E 00 : 0.00 E-01 : 0.00E-01 : 1.3 0E 01:

NE : 0.00E-01 : 4.00E 00 : 4.00E 00 : 2.00E 00 : 0.00E-01 : 0.00 E-01 : 1.00E 01:

ENE: 0.00E-01 : 3.00E 00 : 8.00E 00 : 0.00E-01 : 0.00E-01 : 0.00 E-01 : 1.10E 01:

E

0.00E-01 : 6.00E 00 : 1.30E 01 : 2.00E 00 : 0.00 E-01 : 0. 0 0 E-01 : 2.10E 01:

ESE: 3.00E 00 : 6.00E 00 : 9.00E 00 : 1.00E 00 : 0.00 E-01 : 0.00 E-01 : 1.90E 01:

SE : 1.00E 00 : 1.10E 01 : 5.00E 00 : 4.00E 00 : 0.0 0 E-01 : 0.00E-01 : 2.10E 01:

I SSE: 1.00E 01 : 1.6 0E 01 : 5.00E 00 : 0.0 0 E-01 : 0.00E-01 : 0.00E-01 : 3.10E 01:

S

9.00E 00 : 1.4 0 E 01 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.7 0E 01:

SSW: 1.40E 01 : 2.10E 01 : 1.90 E 01 : 0.00E-01 : 0. 0 0 E-01 : 0.00 E-01 : 5.4 0E 01:

SW 2.10E 01 : 2.7 0E 01 : 1.00E 01 : 0.00E-01 : 0.00E-01 : 0.00 E-01 : 5.80E 01:

WSW: 2.10E 01 : 2.6 0E 01 : 2.00E 00 : 0.00E-01 :

0. 0 0 E-01 : 0. 00 E-01 : 4.90E 01:

i W

3.20E 01 : 1.80E 01 : 4.00E 00 : 0.00E-01 : 0.0 0 E-01 : 0.00E-01 : 5.4 0E 01:

)

WNW: 3.20E 01 : 2.5 0E 01 : 4.00E 00 : 0. 0 0 E-01 : 0. 0 0 E-01 : 0.00E-01 : 6.10E 01:

i 1

NW 1.6 0E 01 : 2.00 E 01 : 7.00E 00 : 1.00E 00 : 0.00E-01 : 0.00 E-01 : 4.40E 01:

NNW: 1.7 0E 01 : 1.00E 01 : 1.00E 00 : 0. 00 E-01 : 0. 00 E-01 : 0.0 0 E-01 : 2.80E 01:

1 TOT: 1.87E 02 : 2.22E 02 : 1.00E 02 : 1.4 0 E 01 : 0. 0 0 E-01 : 0.0 0 E-01 : 5.23E 02:

PERIODS OF CALM (HOURS):

2.000E 00 j

HOURS OF INVALID DATA :

0.000E-01 i

1 l

--r--

--,---,e,

~-,ews

,,---a--

--,v-r-nw-w-- m m

,.e--,--,-

m.,m.-,

,----.7,,wr,,,,-,-,

m y w --, - - -,, - -

-,------m

, ~ -, - - -,,

REPORT CATEGORY.

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER #

4 REPORT START TIME

6552:00 HRS = 12:00AM OCTOBER 1,1986 REPORT END TIME
86 98: 00 HRS = 10:00AM DECEMER 29, 1986 STABILITY CLASS
F ELEVATION 10 METERS WIND SPEED (MPH) AT 10 MEUER LEVEL 1-3 4-7 8-12 13-18 1 9-24

>24

TOTAL N
2.00E 00 3.00E 00 : 1.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 6.00E 00:

NNE: 0.00E-01 : 0.00E-01 : 8.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 8.00E 00:

.....n---------------------------------------------------------------------...--

NE : 0.00E-01 : 1.00E 00 2.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 3.00E 00:

ENE: 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 1.00E 00:

E

0.00E-01 : 4.00E 00 : 2.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 7.00E 00s ESE: 3.00E 00 : 6.00E 00 : 1.00E dl : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.90E 01:

SE : 5.00E 00 : 3.00E 00 : 3.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.10E 01:

l SSE: 4.00E 00 : 2.00E 00 : 3.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 9.00E 00:

S

3.00E 00 : 8.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.20E 01:

SSW: 6.00E 00 : 4.00E 00 : 2.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.20E 01:

SW 1.3 0 E 01 : 2.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.6 0E 01:

WSW: 1.5 0 E 01 : 5.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.00E 01:

W

9.00E 00 : 0.00E-01 : 2.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.10E 01:

WNW: 1.4 0 E 01 : 3.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.80E 01:

NW : 3.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 7.00E 00:

NNW: 1.00E 00 : 4.00E 00 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 6.'00 E 00 :

l TOT: 7.90E 01 : 4.90E 01 : 3.6 0E 01 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 1.66E 02:

PERIODS OF CALM (BOURS):

8.000E 00 HOURS OF INVALID DATA :

0.000E-01

REPORT CATEGORY METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF REOORD.

QUARTER #

4 REPORT START TIME

6552: 00 BRS = 12: 00AM OCTOBER - 1,1986 REPORT END TIME
86 98: 00 BRS = 10 : 00 AM DECENER 29, 1986 STABILITY CLASS
G ELEVATION 10 METERS WIND SPEED (MPB) AT 10 METER LEVEL

==-_

1-3 4-7 8-12 13-18 19-24

>24

TOTAL N
0.00E-01 : 5.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 5.00E 00:

NNE: 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 0.00E-01 : 0.00E-01 : 0.00E-01:

NE : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 ENE: 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

E

0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

ESE: 0.00E-01 : 0.00E-01 : 4.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 5.00E 00:

l SE : 0.00E-01 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.00E 00:

SSE: 1.00E 00 : 3.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 4.00E 00 l

S

5.00E 00 2 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 5.00E 00:

SSW: 1.00E 00 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.00E 00 s SW 0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

WSW: 8.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00 E-01 : 8.00E 00:

W

4.00E 00 : 1.00E 00 2 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 5.00E 00:

i t

l WNW: 7.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 7.00E 00:

NW 5.00E 00 : 0.00E-01 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 5.00E 00 NNW: 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 3.'00E 00:

TOT: 3.40E 01 : 1.30E 01 : 5.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 5.30E 01:

PERIODS OF CALM (HOURS):

3.000E 00 l

HOURS OF INVALID DATA :

0.000E-01 HOURS OF GOOD DATA 2.146E 03 = 100.0% OF TOTAL HOURS i

I l

i


.---,--~n.----._

,_.c.,

l l

-REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 4 4

REPORT START TIME

6552:00 HRS = 12:00AM OCTOBER 1,1986 REPORT END TIME
86 98: 00 BRS = 10: 00AM DECEMBER 29, 1986 STABILITY CLASS
A ELEVATION 60 METERS WIND SPEED (MPH) AT 60 METER LEVEL 1-3 4-7 8-12 13-18 19-24

>24

TOTAL N
0.00E-01 : 1.00E 00 3.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 5.00E 00 NNE '0.00E-01 : 1.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 5.00E 00:

NE : 0.00E-01 : 3.00E 00 6.00E 00 : 3.00E 00 : 0.00E-01 : 0.00E-01 : 1.20E 01:

ENE: 0.00E-01 : 2. 0 0 P. 00 : 3.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 6.00E 00:

- - - - - - -. ~... - - - - - - - - - - - - - - _ - - - - - - - - - - - - - _ - - - - - - - - - - - - - - - - - - - - - - - - - - - _ - - - - - - - - - - _

E

1.000 00 :'1.00E 00 : 0.00E-01 : 5.00E 00 : 1.00E 00 0.00E-01 : 8.00E 00:

ESE: 0.00E-01 : 1.00E 00 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 2.00E 00:

1SE s'0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

SSEs~0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

S

2.00E 00 : 2.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 5.00E 00:

SSW: 1.00E 00 : 4.00E 00 : 7.00E 00 : 9.00E 00 : 1.00E 00 : 1.00E 00 : 2.30E 01:

l SW 4.00E 00 : 3.00E 00 : 1.00E 01 : 2.6 0E 01 : 1.10E 01 : 3.00E 00 : 5.70E 01:

1

\\

WSW 0.00E-01 : 6.00E 00 : 8.00E 00 : 1.10E 01 : 8.00E 00 : 6.00E 00 : 3.90E 01:

W 0.00E-01 : 7.00E 00 : 8.00E 00 : 3.00E 00 : 1.00E 00 : 3.00E 00 : 2.20E 01:

i WNW: 1.00E 00 : 0.00E-01 : 3.00E 00 : 7.00E 00 : 2.00E 00 : 0.00 E-01 : 1.30E 01:

NW 0.00E-01 : 4.00E 00 : 9.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 1.7 0E 01:

NNW: 2.00E 00 : 0.00E-01 : 3.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 5.~00 E 00 :

TOT: 1.10E 01 : 3.60E 01 : 6.50E 01 : 7.10E 01 : 2.40E 01 : 1.3 0 E 01 : 2.20E 02:

1 I

1 l

PERIODS OF CALM (BOURS):

0.000 E-01 l

HOURS OF INVALID DATA :

0.000E-01 1

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 9 4

REPORT START TIME

6552 : 00 BRS = 12: 00AM OCTOBER 1, 1986 REPORT END TIME
86 98: 00 HRS = 10: 00AM DECEMBER 29, 1986 STABILITY CLASS
B ELEVATION 60 METERS l

WIND SPEED (MPS) AT 60 METER LEVEL 1-3 4 '7 8-12 13-18 19-24

>24

TOTAL N
0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00 : 1.00E 00 0.00E-01 : 2.00E 00:

l NNE'0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

NE : 0.00E-01 : 0.00E-01 : 5.00E 00 : 0.00E-01 : 1.00E 00 0.00E-01 6.00E 00:

ENEs.0.00E-01 : 0.00E-01 : 1.00E 00 3.00E 00 : 3.00E 00 : 2.00E 00 : 9.00E 00:

E

0.00E-01 : 2.00E 00 : 0.00 E-01 : 0.00E-01 : 0.00E-01 : 4.00E 00 : 6.00E 00:

ESE: 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 1.00E 00:

SE : 0.00 E-01 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

SSE: 0.00E-01 : 0.0 0 E-01 : 2.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 3.00E 00:

i S

0.00E-01 2 3.00E 00 : 0.00E-01 : 0.00E-01 : 0.0 0 E-01 : 0.00E-01 3.00E 00 SSW: 1.00E 00 : 1.00E 00 : 3.00E 00 : G.00E 00 : 0.00E-01 : 0.00E-01 : 1.10E 01:

SW : 0.00E-01 : 5.00E 00 : 7.00E 00 : 1.20E 01 : 1.00E 00 : 0.00E-01 : 2.50E 01:

WSW: 0.00E-01 : 5.00E 00 : 4.00E 00 : 7.00E 00 : 6.00E 00 : 0.00E-01 : 2.20E 01:

W

3.00E 00 : 3.00E 00 : 4.00E 00 : 7.00E 00 : 1.00E 00 : 2.00E 00 2.00E 01:

WNW: 2.00E 00 : 4.00E 00 : 1.00E 00 : 2.00E 00 : 1.00E 00 0.00E-01 : 1.00E 01:

NW 0.00E-01 : 0.00E-01 : 2.00E 00 : 0.00E-01 : 1.00E 00 : 1.00E 00 : 4.00E 00:

NNW: 0.00E-01 : 1.00E 00 : 2.00E 00 : 0.00E-01 : 1.00E 00 0.00E-01 : 4.~00E 00:

TOT: 6.00E 00 : 2.40E 01 : 3.20E 01 4.00E 01 : 1.6 0E 01 : 9.00E 00 : 1.27E 02:

PERIODS OF CALM (HOURS):

0.000E-01 HOURS OF INVALID DATA :

0.000E-01 l

l

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 4 4

REPORT START TIME

6552:00 HRS = 12:00AM OCTOBER 1,1986

. REPORT END TIME

86 98 : 00 BRS = 10: 00 AM DECEMBER 29, 1986 STABILITY CLASS
C ELEVATION 60 METERS WIND SPEED (MPB) AT 60 METER LEVEL t

1-3 4-7 8-12 13-18 19-24

>24

TOTAL N
0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00 - : 3.00E 00 : 0.00E-01 : 4.00E 00:

I

]

NNE:~ 1.00E 00 0.00E-01 : 1.00E 00 : 2.00E 00 : 0.00E-01 : 0.00 E-01 4.00E 00s NE : 0.00E-01 : 1.00E 00 : 4.00E 00 : 3.00E 00 : 2.00E 00 : 3.00E 00 : 1.30E 01:

ENE: 0.00E-01 : 2.00E 00 2.00E 00 : 3.00E 00 : 1.00E 00 : 6.00E 00 : 1.40 E 01:

E

0.00E-01 : 4.00E 00 0.0 0 E-01 : 1.00E 00 : 0.00E-01 s'5.00E 00 : 1.00E 01:

ESE: 0.00E-01 : 5.00E 00 : 3.00E 00 : 2.00E 00 : 1.00E 00 : 1.00E 00 : 1.20E 01:

SE : 2.00E 00 : 3.00E 00 : 0.00E-01 : 1.00E 00 : 2.00E 00 : 1.00E 00 : 9.00E 00:

\\

SSE: 0.00E-01 : 1.00E 00 0.00 E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 2.00E 00 S

0.00E-01 : 4.00E 00 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 5.00E 00:

SSW: 1.00E 00 : 1.00E 00 : 2.00E 00 : 3.00E 00 : 3.00E 00 : 2.00E 00 : 1.20E 01:

SW 0.00E-01 : 3.00E 00 : 1.7 0E 01 : 1.6 0E 01 : 1.10E 01 : 3.00E 00 5.00E 01:

WSW: 0.00E-01 : 2.00E 00 : 1.30E 01 : 1.30E 01 : 5.00E 00 : 1.20E 01 : 4.50E 01:

W

1.00E 00 5.00E 00 : 2.00E 00 : 1.00E 01 : 3.00E 00 : 3.00E 00 : 2.40E 01:

l WNW: 1.00E 00 : 1.00E 00 : 2.00E 00 : 4.00E 00 : 1.00E 00 : 0.00E-01 : 9.00E 00:

I Mi : 0.00E-01 0.00E-01 : 2.00E 00 0.00E-01 : 2.00E 00 0.00E-01 : 4.00E 00:

~

NNW: 2.00E 00 : 0.00 E-01 : 0.00E-01 : 4.00E 00 : 2.00E 00 : 0.00E-01 : 8.00E 00:

TOT: 8.00E 00 : 3.20E 01 : 4.80E 01 : 6.50E 01 3.6 0E 01 : 3.60E 01 : 2.25E 02:

PERIODS OF CALM (HOURS):

0.000E-01 HOURS OF INVALID DATA :

0.000E-01

.. ~

REPORT CATEGORY

NETEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER ' 8 4

REPORT START TIME

6552:00 BRS = 12:00AM OCTOBER 1,1986 REPORT END TIME
86 98: 00 HRS = 10:00AM DECEMBER 29, 1986 STABILITY CLASS D

ELEVATION 60 METERS WIND SPEED (MPH) AT 60 METER LEVEL 1-3 4-7 8-12' 13-18 19-24

>24

TOTAL i

N

1.00E 00 : 3.00E 00 7.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 1.50E 01:

NNE: 2.00E 00 : 1.00E 00 6.00E 00 3.00E 00 : 0.00E-01 : 1.00E 00 : 1.30E 01:

NE : 0.00E-01 : 4.00E 00 : 2.6 0E 01 : 2.50E 01 : 0.00E-01 : 0.00E-01 : 5.50E 01:

ENE: 0.00E-01 : 1.00E 00 : 1.6 0E 01 : 2.90E 01 : 7.00E 00 : 2.00E 00 : 5.50E 01:

E

2.00E 00 : 2.00E 00 : 5.00E 00 : 9.00E 00 : 1.00E 00 : 5.00E 00 2.40E 01:

ESE: 0.00E-01 : 8.00E 00 : 2.00E 00 2.00E 00 : 1.00E 00 : 7.00E 00 : 2.00E 01:

SE : 0.00E-01 : 1.80E 01 : 1.20E 01 : 1.00E 01 : 0.00E-01 : 0.00E-01 : 4.00E 01:

SSE: 3.00E 00 : 1.00 E 01 : 7.00E 00 : 1.00E 00 : 0.00E-01 0.00E-01 : 2.10E 01:

)

S

0.00E-01 : 1.10E 01 : 1.6 0E 01 : 1.00E 01 : 0.00E-01 : 0.00 E-01 : 3.7 0E 01:

SSW 0.00E-01 : 6.00E 00 : 1.60E 01 : 2.20E 01 : 1.6 0E 01 : 2.00E 00 : 6.20E 01:

SW 1.00E 00 : 1.40 E 01 : 4.30E 01 : 4.50E 01 : 2.00E 01 3.00E 00 : 1.26E 02:

WSW: 1.00E 00 : 1.80E 01 : 4.40E 01 : 5.00E 01 : 1.70E 01 : 6.00E 00 : 1.36E 02:

W

0.00E-01 : 2.90E 01 : 2.00E 01 : 3.80E 01 : 4.00E 00 : 3.00E 00 : 9.40E 01:

l WNW: 1.00E 00 : 1.10E 01 : 1.6 0E 01 : 2.50E 01 : 2.00E 00 : 0.00 E-01 : 5.50E 01:

l NW 1.00E 00 : 5.00E 00 : 1.00 E 01 : 9.00E 00 : 1.00E 00 : 0.00E-01 : 2.6 0E 01:

NNW: 4.00E 00 : 8.00E 00 : 1.40 E 01 : 1.10E 01 : 0.00E-01 : 0.00E-01 : 3.7 0E 01:

TOT: 1.6 0E 01 : 1.49E 02 : 2.60E 02 : 2.93E 02 : 6.90E 01 : 2.90E 01 : 8.16 E 02:

l 1

PERIODS OF CALM (HOURS):

3.000E 00 HOURS OF INVALID DATA :

0.000E-01 l

4 l

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 9 4

REPORT START TIME

6552:00 BRS = 12:00AM OCTOBER 1,1986 REPORT END TIME
86 98: 00 HRS = 10: 00AM DECEMBER 29, 1986 STABILITY CLASS
E ELEVATION 60 METERS WIND SPEED (MPH) AT 60 METER LEVEL 1-3 4-7 8-12 13-18 19-24

>24

TOTAL N
1.00E 00 1.00E 01 : 9.00E 00 : 2.00E 00 1 0.00E-01 : 0.00 E-01 : 2.20E 01:

r NNE: 0.00E-01 : 3.00E 00 : 3.00E 00 : 5.00E 00 : 0.00E-01 2.00E 00 : 1.30E 01:

NE s ' l.00E 00 : 1.00E 00 : 6.00E 00 : 3.00E 00 : 3.00E 00 : 0.00E-01 : 1.4 0 E 01:

ENE: 0.00 E-01 : 1.00E 00 : 8.00E 00 5.00E 00 0.00E-01 : 0.00E-01 : 1.40E 01:

E

0.00E-01 : 0.00E-01 : 0.00E-01 : 1.3 0E 01 : 6.00E 00 : 0.00 E-01 : 1.90E 01:

ESE: 0.00E-01 : 0.00E-01 : 6.00E 00 : 7.00E 00 : 3.00E 00 : 2.00E 00 : 1.80E 01:

SE : 0.00E-01 : 8.00E 00 : 8.00E 00 : 7.00E 00 : 2.00E 00 : 0.00E-01 : 2.50E 01:

SSE: 1.00E 00 : 1.00E 01 : 6.00E 00 : 6.00E 00 : 0.00E-01 : 0.00E-01 : 2.30E 01:

S

1.00E 00 : 5.00E 00 : 1.20E 01 : 1.00E 01 : 1.00E 00 : 0.00E-01 : 2.90E 01:

i SSW: 0.00E-01 : 6.00E 00 : 1.10E 01 : 1.80E 01 : 1.10E 01 : 1.00E 00 : 4.70E 01:

SW 1.00E 00 : 4.00E 00 : 2.10E 01 : 2.20E 01 : 1.00E 01 : 0.00E-01 : 5.80E 01:

WSW: 0.00E-01 : 5.00E 90 : 2.6 0E 01 : 2.50E 01 : 1.00E 00 : 0.00 E-01 : 5.7 0 E 01 '

1 W

0.00E-01 : 4.00E 00 2.70E 01 : 8.00E 00 : 3.00E 00 : 0.00E-01 : 4.20E 01:

WNW: 2.00E 00 : 1.6 0E 01 : 2.6 0E 01 : 1.7 0E 01 : 1.00E 00 0.00E-01 : 6.20E 01:

NW 2.00E 00 : 1.90E 01 : 1.4 0E 01 : 1.30E 01 : 2.00E 00 : 1.00E 00 : 5.10E 01:

NNW: 0.00E-01 : 1.10E 01 : 1.7 0E 01 : 2.00E 00 : 1.00E 00 : 0.00E-01 : 3.10E 01:

TOT: 9.00E 00 : 1.03E 02 : 2.00E 02 : 1.63E 02 3 4.40E 01 : 6.00E 00 : 5.25E 02:

i PERIODS OF CALM (HOURS):

0.000E-01 HOURS OF INVALID DATA :

0.000E-01 i

i 4

REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 8 4

REPORT START TIME

6552:00 HRS = 12:00AM OCTOBER 1,1986 REPORT END TIME
86 98: 00 BRS = 10: 00AM DECEMBER 29, 1986 STABILITY CLASS
F ELEVATION 60 METERS WIND SPEED (MPH) AT 60 METER LEVEL 1-3 4 -7 8-12 13-18 19-24

>24

TOTAL N
0.00E-01 : 1.00E 00 : 1.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 2 3.00E 00

1:

NNE: 0.00E-01 : 1.00E 00 : 2.00E 00 : 7.00E 00 0.00E-01 : 0.00E-01 : 1.00E 0 NE : 0.00E-01 : 0.00E-01 : 0.00E-01 2 3.00E 00 : 0.00E-01 : 0.00E-01 2 3.00E 00:


0:

ENE: 0.00E-01 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 2.00E 0


0:

E

0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 3.00E 00 : 0.00E-01 : 3.00E 0 ESE: 0.00E-01 : 1.00E 00 : 2.00E 00 : 9.00E 00 2.00E 00 : 0.00E-01 : 1.40E 01:

p y

SE : 0.00E-01 : 0.00E-01 : 6.00E 00 : 1.00E 00 : 3.00E 00 : 0.00E-01 : 1.00E 01:


1:

SSE: 1.00E 00 3.00E 00 : 6.00E 00 : 3.00E 00 : 0.00C-01 : 0.00E-01 : 1.30E 0 S

2.00E 00 : 2.00E 00 : 3.00E 00 : 1.00E 00 : 1.00E 00 : 0.00E-01 : 9.00E 00:

SSW: 3.00E 00 : 1.00E 00 : 5.00E 00 : 5.00E 00 : 1.00E 00 : 0.00E-01 : 1.5 0 E 01:

SW 1.00E 00 : 6.00E 00 1.20E 01 : 6.00E 00 : 2.00E 00 : 0.00E-01 : 2.7 0E 01:

WSW: 0.00E-01 : 2.00E 00 : 1.20E 01 : 3.00E 00 : 0.00E-01 0.00E-01 : 1.7 0E 01:

W 0.00E-01 : 3.00E 00 : 7.00E 00 2.00E 00 : 0.00E-01 : 0.00E-01 : 1.20E 01:

WNW: 1.00E 00 : 2.00E 00 : 7.00E 00 : 2.00E 00 : 0.0 0 E-01 : 0.00E-01 : 1.20E 01:

NW 0.00E-01 : 2.00E 00 : 9.00E 00 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.10E 01:

NNW: 1.00E 00 : 3.00E 00 : 4.00E 00 : 1.00E 00 : 1.005 00 : 0.00E-01

1. DOE 01:

TOT: 9.00E 00 : 2.70E 01 : 7.70E 01 : 4.40E 01 : 1.4 0 E 01 : 0.00E-01 : 1.71E 02:

PERIODS OF CALM (HOURS):

3.000E 00 HOURS OF INVALID DATA :

0.000E-01

l REPORT CATEGORY

METEROLOGICAL DATA.

QUARTERLY TOTALS OF HOURS AT l'

EACH WIND SPEED AND DIRECTION PERIOD OF RECORD
QUARTER 9 4

i REPORT START TIME

6552 : 00 HRS = 12: 00 AM OCTOB ER 1, 1986 REPORT END TIME
8698: 00 HRS = 10: 00AM DECEMBER 29, 1986 l

STABILITY CLASS

G ELEVATION 60 METERS i

WIND SPEED (MPH) AT 60 METER LEVEL 1-3 4-7 8-12 13-18 19-24

>24

TOTAL N
0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00 NNE: 0.00E-01 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 1.00E 00:

NE :-1.00E 00 0.00E-01 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 5.00E 00:

ENE: 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 0.00E-01:

i E

1 ESE: 0.00E-01 : 0.00 E-01 : 0.00E-01 : 1.00E 00 : 4.00E 00 : 0.00E-01 : 5.00E 00:

SE : 0.00E-01 : 0.00E-01 : 1.00E 00 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 3.00E 00 SSE: 0.00E-01 : 1.00E 00 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 3.00E 00:

S

0.00E-01 : 1.00E 00 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 3.00E 00:

SSW: 0.00E-01 : 1.00E 00 : 5.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 6.00E 00:

SW 0.00E-01 : 1.00E 00 : 1.00E 00 : 0.00E-01 : 1.00E 00 : 0.00E-01 : 3.00E 00:

WSN: 0.00E-01 : 1.00E 00 : 1.00E 00 : 2.00E 00 0.00E-01 : 0.00E-01 : 4.00E 00:

W

1.00E 00 : 2.00E 00 2.00E 00 : 2.00E 00 : 0.00E-01 : 0.00E-01 : 7.00E 00 WNW: 0.00E-01 : 3.00E 00 : 4.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 7.00E 00:

l 1

l NW : 1.00E 00 : 4.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 6.00E 00:

~

NNW: 0.00E-01 : 1.00E 00 : 1.00E 00 : 0.00E-01 : 0.00E-01 : 0.00E-01 : 2.00E 00:

TOT: 3.00E 00 : 1.6 0E 01 : 2.50E 01 : 7.00E 00 : 5.00E 00 0.00E-01 : 5.60E 01:

PERIODS OF CALM (HOURS):

0.000E-01 HOURS OF INVALID DATA :

0.000E-01 HOURS CF GOOD DATA 2.146E 03 = 100.0% OF TOTAL HOURS

m DCIDSUPS 7 f,HATEES 'IO TIE PROCESS CXXT1WL PROGRN1 w

-.w3

f]/[

Fet 12.000.104

  • . Page 1 of.I 110686 s

PeoCESS CONTROL pB0GRAN CEADGE E QtEST Change nequested by: 0. TtJEA6sk Date: I2 t1 Pfe Department /Sectiea: Afi/C L EAG

/ ft%eWeD-JAArMs?B Applicable Sectleete):

SEcnod u dan Amn smrar /

Change (Attack Markope to the PCp): 8ese a //sr/cm/ No,Ing i

)

Reason for Change / Justification (Include sufficiently detailed information to totally support the rationale for the change. Attach additional sheets if necessary):f"A a.

.1 * *E'J L s 1" A 16 -- L.., e L : :2ti, 1 w :,

u.

1:..

v ri.,L.n f2:rlic

  • e, ".i..L 1,. & -

LNR.

All >L e2. -. w TJrt M f,a.,a t.21A, a,Z L n:1 <12,:I n L:, 'd.J L L. r / L

't4 a.2',.L e aan L r e'l n J.

7124.% 4L lt - n.a T/

/< n L ~f11L.. rL-n ~hXJ L '" se t " f-e -s sa n,1-f_/n e.

Ett" (/L,L 2') /d (A *r%CL C&~1h-

e. Je n-_ % ~v/ tr J. ~ l'e,C.

eudM b 4 f 'rt). '71 n,b J c.k.fi 1 uile 1Z 1. 5:a d sal-2~f W(A M"W n.

Review performed by:

Med '/1 o

Date: /2.!/r!Ps GenersT Supervisor, Radweste The Superintendent Operations has determined, as evidenced by his signature below, that this change does not reduce the overall conformance of the solidified waste product to existing criteria for solid wastes.

[M- {

13!EY 86.

Qd J

Approved by:

Dete:

Superiet est, Operations

~

,1Z/2 f/N accommended by:

Th Bote:

B0 Chairman Approved by:

f, AM[

3ato:

/

7 f ri t m.na, f Eun e

L_______-_---_--__-__-___----__--_---

Rev. 4 1715 FENII 2 FROCESS GMrFROL PROGRAN 8c The Fermi 2 Process Control Program (PCP) covers the f

following distinct praaa==== for solidifloation or deustering of j

radioactive unste. These praaa==== are described below:

y 1.

For the solidification of radioactive unste using the Fermi 2 permanent solid radunste system, Fermi 2 mill follow the PCP described in Attachment 1.

2.

For the dountering of radioactive powdered resins in steel containers mains the Bittaan Nuclear Incorporated temporary redunste processing system, Fermi 2 will follow the PCP described in the Rittaan Nuclear Document STD-PCP-03-001 Revision 3

3. For the sountering of radioactive tend resins in steel containers using the Bittaan Nuclear Incorporated temporary radweste processing system, Feral 2 will follow the PG' described in the Bittaan Nuclear dooment STD-F-04-002 Revisicin 5.

N 4.

For the dountering of radioactive powdered resins in Radick High Integrity Containers (HIC's) using the Rittaan Nuclear Incorporated temporary radwaste processing system, Fermi 2 7

will follow the PCP described in the Rittaan Nuclear Document STD-PCP-03-002 Revision 0,- 1.

Q The General Supervisor - Radunste is responsible for the implementation of the Fermi 2 FCP. Nuclear Quality Assurance will audit the solidification 7

and dewatering of radioactive vaste including record keeping activities A

in accordance with QAPR 24.

J '/4/Isv

///

/PC-Recommended:

Date Sufvjsor-Radwaste ff : is $* 7. g y

era A __

Noted:

/

o Approved:

05R0 Chairman Date~

NOTE: The Rittaan Nuclear documents referenced above contain proprietary information, are not published as Fermi 2 doceents, and are available from the General ly Supervisor, Radmaste.

GONTROLLED me rmE.INFoRMATioN sYSTEMSosN RtP nhetl f

Pts NGE NEV OCT 11 1Hk3I3 m

NEC;PIENT.

APPROVAi RIC? YES NO i

l d

PCP Manual Rev. 4 Paga 3 ef 7 j

3.

Sources of Wastes Mastes to be processed by the permanent solid unste system are of three types:

Sht/Ses 1.

Poudered resins and abusN es from the reactor unter clean-up y/

system, the aandannate demiueralisers, backunsh of the fuel pool and radunste system filter /demineralisers, and redunste System etched disc filters.

2.

Boad, resins from the 11guld radunste system desineralisers.

3 concentrates from the liquid reduasta evaporator bottoms and ehloride unste tank.

Duringnormaloperations,powderedresins[ sludges,andband resins are processed through the centrifuge from the centrifuge feed tank. The dauntered radweste is then " dry fed" by gravity to the extruder / evaporator.

Additionally, powdered resins and sludges may be ' slurry fed" directly to the estruder/ evaporator from the centrifuge feed tank. Bead resins may also be " slurry fed" to the estruder/

swaporator from the slurry feed tank. Because of the larger amounta of unter which must be handled by the extruder / evaporator in the slurry feed mode, processing times will be somewhat longer, although product adequacy will be unaffected.

(

Concentrated solutions of radsalts f:'on the raduaste evaporators are fed directly to the estruder/ evaporator.

Regardless of the feed mode, vaste feed rates are automatically measured and regulated. Asphsit feed rates are automatically adjusted based on the waste feed rates to provide the desired binder /uaste ratio.

III. Variables Influencing End Product Properties Certain process variables have a direct bearing on the properties of the final product which relate to the ability to form a freestanding l

monolith with no free unter. Plant procedures will detail the sampling requirements necessary to insure proper solidifloation. The system will normally be operated with the extruder feed within a specified pH range in order to protect equipment from corrosion, and operations within this range will assure proper solidification and end-product.

l t

l l

l i

e

--.,,-,--n,,,-_n,

,_-.,-n-

PCP Manual Dev. 4 Page 7 cf 7

[

waarm 14 6 FARAIETERS j-TO EM501E TE.MINIIEM II.I.-.

  • IM5TAE 2" utSTE 50W8 ARE IET MTWE PNFILES*rei nes: s cound)/RM&t*4es
  • /

Ione i

2 3

4 5

(7 +

s e e ne w *

  • e* !M Temperature (0FFV **

-E 3 5v h E

  1. /

swanorator M

  • Ione 1

2 3

4 5

(# +-

a 200 2.90 320 SSB '.3,9 200 3

_!# N N,,, d_ d d 2 Nk, p

Temperature (O yeg y

WASTE / ASPHALT RATIO #

c.u ost d ;

Evaporator Battees 5 50/50

  1. l be )tuM/no. dud bsins(Ecosar *)lRHerSidf/50

(

h eno m edse.

55 LINIT ON OIL IN FEED STREAM One percent ASPHALT TYPE Meet ASTM D-312-71, Type III

  • The values given in this section are tentative. The preoperational test program will determine the high and low ranges of these variables for acceptable solidification. Final operating points and acceptable ranges will then be incorporated in a revision to this PCP.

5 T1b ber4 ineohenkeyorikyo k noselkrley ey 4 yy,,jfjg JE.3 s offresinkly etem6:ea+ mperehrt.

a i

e Ti.perdsee ese 6a. Aerie) by.9o +n tok /+ts.comjoojat e n 7Aes 4As quU+y e4 +As est froduct" vim + a%H9

l AWumpmee IWant Oprars Oks i

19tknen Nuclear W

py,T, "

hicorporeigd Gree, anos li0134 912) 2324133 Refer to:

HN-4082 December 12, 1986 i

i Mr. Craig Weber Radwaste Supervisor Detroit Edison Company Fermi 2 Power Plant 6400 North Dixie Highway Newport, Michigan 48166

Subject:

Revision Of STD-PCP-03-002

Dear Mr. Weber:

Please be advised that Westinghouse Hittman has revised STD-PCP-03-002, " Process Control Program For Powdered Resin Transfer And Dewatering Using RADIDK High Integrity Containers". The revision date,is 12/10/86 and the revision number is No. 1.

The revision was made for the following purposes:

1.

Included Ecosorb and Ecoccat in the scope Paragraph'1, Page 2.

2.

Revised title of the system layout drawing listed in the reference i

drawing section.

l 3.

Permited optonal methods of securing quick disconnects.

4.

Inserted note, after step 6.4.13 which makes optional the dewatering pump checkout.

5.

As a clarification inserted note after 7.3.2 which lists data to be recordad.

6.

Inserted as an option the use of radiation levels on the tram fer hose i

l as an indication that a flush is complete.

l l

l l

1

~

Mr. Craig Weber December 12, 1986 Page 2 7.

Inserted note after 9.3.7 to make draining the vacuum receiver tank optional at the Hittman operator's discretion.

8.

Made optional plant initials for the data sheets.

9.

Omittsd the time column on Attachment C since it was unnecessary.

If you require further information on this matter, please give me a call.

Sincerely yours,

/

./

o tc<.

~

l Tony Leve1 ng Project Manager TL:jd l

l O

,-.,n

l l

WasteChem l

l weseechem carpersuon i

one xenes way i

Paramus, PLI 07062 l

201/500 2000 December 2, 1986 T een:eessasi l

l l

Mr. Craig T. Weber General Supervisor - Radwaste 1

Detroit Edison Company 6400 N. Dixie Highway

)

i Newport MI 48166

Subject:

Fermi 2 VRS Solid Radwaste Process Control Program (PCP)

Dear Mr. Weber:

Based on the most recent Wastechem Corporation 10CFR61 testing as issued in the " Topical Report 10CFR61 Waste Fom Conformance Program for Solidified Process Waste Products Produced by a WasteChem Corporation Volume Reduction and Solidification (VRS) System", dated l

l May 19, 1986, the temperature profiles for Extruder / Evaporator l

processing have been updated as detailed in Section 3.3.3 of the l

referenced Topical Report. These temperature profiles are the recommended setpoints for processing of the various waste types.

l These setpoints supercede any previous temperature profiles listed i

in the Femi 2 VRS Operating Manual which was issued previous to the May 19, 1986 Topical Report. However, the Fermi 2 Operator Training Manual Process Control Program lesson was based on this latest Topical Report since it was prepared after this Topical Report. These temperature profiles are provided as Attachment 1.

A variation of up to 10% from these setpoints will not present any problem with the quality of end product (e.g. 300*F is 270*F -

l 330*F).

l The optimal temperature profile for Femi 2 waste forms should be developed based on an optimization program on your system. WasteChem Corporation would be pleased to provide the necessary assistance to implement this program.

Sincerely yours.

WasteChem Corp r ti rVA. %

Timothy C. Power Group Supervisor, Construction Start-up & Testing

)

l TCP/ss Attachment

[M.c aux's 2.

ATTACMENT 1 3.3.3 Process Temperature A proper temperature profile alang the-1ength of the-extruder / evaporator is required to provide adequate evaporative l

!.j capacity, and to assure that free water is not discharged from the i

. nachine. Typical process temperature profiles are as follows.

  • PROCESS TEMPERATURE (F')

WASTE TYPE SARREL:

1 2

3 4

5 6/7 8

    • 85 200 280 320 350 300 190 8EAD RESIN PREC0AT FILTER CAKE W/

85 200 280' 320 350 300 190 l

l POWDERED RESIN PREC0AT FILTER CAKE W/

85 200 280 320 350 350 280 DIATSIACEDUS EARTH EVAPORATOR CONCENTRATES 85 200 280 320 350 350 280 DECONTN11 NATION WASTE 85 200 280 320 350 350 280 MIXED RESIN AND FILTER CAKE 85 200 280 320 350 300 190 f

Temperatures are approximate. Fleid setpoint changes may be s

L required to optimize the process. These changes can be made at L

the temperature indicating controllers, r

I This barrel temperature is ambient, or approximately 85* F.

j Low temperature alarms are provided to alert the operator to a low L

temperature to assure the absence of free water.

r L

I r

O

~

f/. ~C L CSk 2-

17IS

.s 1

/spg

.12.000.108 Page 1 of 3 i

l PROCESS CONTROL PROGRAM CEARCE REQUEST Change Beguested by:

7//

Date: 7.27 m-

/

a Departaast/Secties: Id A__

_I--

U-T Applicable W / 2.

23 } N A 2..S. lls. '> R *$ 1)>1

- SeeAleate): -

(AttackMar5"XhJL..ato the PCF.):

eM d__I I41def h/*

k aYs a l. - L

m. L.

J.1r,. ALc-g A _;G' n 1,,,

EeeL'M%

a v

j Reason for Change /Jsstificaties (Include sufficiently detailed information to totally supp / m.-t the rationale for the change. Attach additional sheets if necessary):

. AT/_C 1lltf **/" 2 dC' A/# _*

-m 4 - A

, L.:. M J L _

a.a. 2,22,.,

rl-

- n 1'yjL[1r*srf

-/

o ms:At',.1 4 1 A H 4.-t11 ku.5 6- - - W %- A sa r F

/

.a.

l{

Q

- L'.

n - >f 5 nw' - L. a.I;:-t s < -_

u_. aw f.

M- -u L K f1L__'ar2*

11.,-

a.&. Ds 2-FL _. g w fgy r

v wir6Aff N & mand.T & k J L M d kL 21 L J ~ 1 J u LiuTN

. + A.,

L.-

A LJ.,1,.us n L*1;L M M.Q u L &

1 x f

(cMu ). !

f!.2 7[27, Review Performed by:

sa Ye/

u Deter Generf1 Sepervisor - Radweste The.pdchen Engineer has determined, as evidenced by his signature below, that this change does not reduce the overall conformance of the solidified riste product to existing er teria for oli stes.

Date: 9MI

. Approved by:-

a.

seer Racesusended by:

Bate: /psb yD-Bote: /4 )

Appreeed by:

Assistant Manager-Emelest Producties ARMS-INFORMATION SYSTEMg me m AER neNMPbalAM.t.

. CONTROLLED

" M

(

OCT 11 105 i,

092005 END fb&

9tS RECIPENI APPROVAL REQ *D:

YES--

NO e--e---esw-9

-aai m

-_-.-.---w-_-,--e.-,,-.,-me,w,mp---m...ww wum.ww.e-1,--e,gm m-w w,en w w-_

c-e.-.r-rm

_,, ge g eww-W ge gp yy $

.- w.erp-.,i.--

--v-

o

t$h m. 6.., D. w-., -. - o c s, -. m y

.....&f

--Ga.t) ' $>YW$4.

H M5^ 4SAr -

-.-0e.

S727-A-03-coS~

  • C

,-- A,-1,2 AL 1.1/L L Lf~~~.

~.

IE M t e n. ?. & # ~..# N W '-'~ M

.Y=W W &,-

r a

y

/>2 m '1t, CL -.

- 12 :KJ L _ #sey # l _ s.. ]__,,,-.g gg g _: 1 xr

.. %. Y h /.

1 5.

d G _. J'1 _f 2 / 1 2f-n,

-...--r n.

.a

. 'n:.. t4t~., e,1 - x1:. in

, an u,,w.

'L $1"[.A ts_ ?>-.T.A. Inepiskt'sfn). U.. M -zG fc/o fd A.-.1 t

" -- M.* O '

, A m -2.e. E A & $ p~.

rk.

L J.r u ="r

-d> Ma r L, _-

e

- u,,.

gf rY 3 >_-

$2>-/C A/g

^-

_.ZA' Sw.J_C - -- L A >

x-a aa K,

- r1 -t.u,

.1__._

r r

(

I o.een

.e.

.. * ". = *

  • e.

_____.,,,,-.,,,-----.--,--e,

.----,,-n,

--,n-

+ - - - - - - - -

a,

,m,

j s)C/f '

Rev. 3 l'~

t FERH1 2 PROCESS CONTROL FROGRAM "fde h M3

$ The Fermi 2 Process Centrol Fregram (PCF) covers =64eo-distiset processes for solidification or deusterias of radioactive unste. The4 eve processes are described b41ews

. 5T'.

Z5 d_N_bk_ :T!b'

N _. __..- li G ',h h E *f EU5'fE'-55[i:5' 55 5'_ _E'5 5_ - E5 [.i.' - T ~".31~ _5-

~

bwn:

n:= = :1: - 2 '

_:2=n,:=.

2.

E __hhJhgh5 h

g q,, g g y

_mh_

_a

' 'r:M ::_'!!!'.;; "21

.i :2_..;

2 4.

2

'_ '3:!'.:::-L'~. Z :'.'__ 12T_:'-~.'~'__:;_,. M.";;.W ',-

'; W ;: '. ;;
i._.

_1: 7 _ ;. ' ; i ~; ; 122

_ :: _. : ','. ' __ :_ _ _ _ _'_ _ '_ _ _ ';_ _ ~~

' ' - ~ ~ ~ - " ' ' ' ' ' ' ' ' ' ' ' - - - ' ' '

1

__T 3.

For the solidification of radiesetive weste using the Fermi 3 permanent solid radwaste system. Fermi 2 will fo11:w the PCP described in Attachment 1.

4.

For the dewatering of radioactive powdered resins in steel

(

containers using the Rittaan Nuclear Incorporated temporary

(-

radweste processing system. Fermi 7 will follow the PCF described j 3 in the Rittman Nuclear Document STD-PCP-03-001 Revision 3.

a 5.

For the dewatering of radioactive bead resins in steel cor. tainers using the Bittman Nuclear Incorporated temporary radweste processing system. Fermi 2 will fo116v the PCF describe 3 in the Rittssa Nuclear document STD-F-04-002 Revision 5.

The General Supervisor - Radweste is responsible for the implementation of the Fermi 2 PCP. Nuclear Quality Assurance will audit the solidification and devotering of radioactive weste including record keepias activities in

.lC 1

accordance with Q&FR 24.

II E

b A T4

~> G(

  • 'Ge Supervisor adweete' Atc

,f, pQ e

Recommended:

!fd

/

f[Noted:

Y N 7-

\\h

\\"

vl4,,f,,,#ppQ4 te.

5 N

}

E[: "- '- = 'S

/

I e Approved:

e--

E OSR0 Chairman

Afg, De

},

e k gg-E i

The=WWD-ene Rittman Nuclear documents referenced above contain

.I WOTE:

proprietary information, are not published as Fermi 2 I

documents, and are available :r'; ' rom the General Supervisot, g

Radweste.

g If

. hd*"'M

..,6 m a Rad /J "

2 C L.

Et

+ ca r,y t,fu W A/ L L

it' hh$155Y$$&fl f ff-cc1/sMO.

,n.,,n.__,

l

-_ ~__

4= l j

PCP Manum 3,, g.

1 l

Page 5 et g j

i

(

1 poport, WPC describes results of testing performed 4

to demonstrate the ability of the estroser/

evaporator system to predece an adequate product.

The slastated waste systems tested are somserve-tively representative of the Forms wastes espected to be processed by the estreder/ evaporator (notic acid and sodium sulfate should not We present ta Forma mastes).

In support of the Fora! 3 installaties WFC per-formed additiemal testing to eenfirm the edegesey of eyeration with er feeds seek as these result-Sag sees processing the sentritage. These results confire the a egency of presset predeeed

.esing the dry feed sees.

WPC has placed a limit of a pereent all in the waste feed streams. An estensive review of the entire Feral liquid and solid redweste processtag systems failed to identify a eredible mechanism for eencontration of e11 sa solid waste processing feed streams, such that the 1 percent limit would be approached. govertheless, a process limit of a percent oil in the waste-feed stream to the estruder will be maintained. Implementing proce-deres will detail the methods used to ensure this limit is set.

I g

C.

Ratio of waste to Asohalt The limits for the ratio of weste to asphalt to ensure aNacceptable product are presented in Table.4,W 1f the ratio of waste-to-asphalt were to

,/

exceed the limits, the end product viscosity will increase and the end product any exhibit a grainy This could result in " pyramiding" of the textur e.

product in the container with a loss of falling With lower than specified ratios, efficiency.

product properties approach those of pure asphalt, resulting in toes of volume reduction. In any event, the product will be a freestanding sonolith Constant wieving of the product upon eooling.

texture dartog contalmer filling is available to the operator through a closed Carenit Television I

Camera.

l I

Desired waste-to-asphalt ratios in the product a,re i

maintained automatically by a esordinated propor-tioning feed system to the estruder/ evaporator.

In all feed modes, the solids content of the west' 4

1 l

l

~

~-

4

,?-

.FCP Manual Rev 1 e

Fase 6 of g

+

stream is seassred prior to initiation of fees 5

The measured eelids sentent is used to go.

termine the proper weste and as@14 See8'eentrol flow.

h i

. settings by eeneetting a graph sa t e operat ngA separate graph precedure.

each waste species and eaak f,ee8 mode.

In the centrifege feed meet, the flow este to the sentrifuge se sentreated asteentically males a trith a enifers feed, the flew eentrel selee.

sentrifuge will prestee e eniform flow of gries (apprestaately 40-80 w/o selles) predett as fees to the estreser/eesperater.

In both starry feed modes ene in the eencontrates feed code, eonatant waste flew rates are main-toined by flow esasurement with feed back centrol to enriable speed eetering pumps.

Process Te; :rature Profile D.

A prepar temperature profile along the length of free water the outruder is required to ensure that The process temperature ranges is not discharged.

for each of the Feral 2 waste types are given in Table 4.-fg, et/

Low temperature alares are provide 6 to alert the operator to a low temperature out-of-apecifiention

(

condition.

Should an out-of-specification condition persist for two (2) sinutes, the entruder/ evaporator wall be automatically tripped to prevent free water Under from being discharge 8 into the container.

this condation, residual free water in the entroder/ evaporator sannot he discharged since the residual heat sentent of the eachine itself is outiicient to evaporate it.

IV.

spent Filters spent eartridge filters will either be air-dried, compacted, and disposed of as Dry Active teaste (DW),

placed in druma with an abscrbent as required, or

~

placed in drums to be filled with asphalt.

Spent eartridge bundles free the Itaste&golleeter 011 Coaleseer er from the Floor Drain Oil Coalescer will beEach homele f/

encapsulated in asphalt.

S bmmum umu imm

..........mm.M

s4 PCP Manuel Revk Page 7 of 9 t

Sy drip dried, placed in a dres, transferred to the turntable of the solidification system, and thereupon filled with asphalt / waste sistere free the estruder/

evaporator.

This method of ett filter eneapsulaties will be' preven during the prosperettoest test.

T.

eenforennes to SOCPR part $1 l

(Land Diesesel of medioactive Waste)

A.

Forst-2 will aset the waste elassification requirements of 20CrR61.55 by the following:

1.

Nessuring gemaa-emitting radionuclides and using interia correlation factors based on calculational methods described la the Atesie Industrial Forus's "Nothodologies for Determining the Classification of Low-Level Radioactive Westes Fres poclear Power Plants."

2.

Carrying out a sampling and analysis program necessary to determine subsequent specific corre-lation factors to be used for the plant.

f

f

(

(

3.

If the subsequent sampling and ansyleis prograr.

indicates results such that the correlation f actors being used say not give upperbound lizits, then the wastes will he stored until they ear, be classified on the hesis of correlation factors developed from actual sample analysis.

B.

Fermi 2 will meet the waste form requirements of 20Crm61.56 d en solidifying waste using the estruder/

i evaporator by the following:

Whith a et af dheo o,se. /*]seltek t/

83*** ^ ****** Mi i i r JE !? 9 5is D "'_"

2-i

r x : n. "c a a...ai.ii a ; m m :__:":-

t XI IC:i;;;;= :e

^--m. :: ::fiMI idii'Ee -

i

.assete,-

by +Ae harl*/ CNan Yi n N W Y*** d 10 CF26l.56 h) SA*// be brast) %shble'.

I UAsiabk wash JFrec estdby fAe Fre i 2 f res a.+ reluask Sys k SAe d nr o e+M lAnto**hr ref M'[**W' //s fen / h K/,k M,

)

, _. _... -. _.. ~.

. ~.

e.

prp8 I

p.1' a '

a'j -

FCF M.nua,l Rev (('

..te..,

8I.[4 e prior to the se1846fiestion of ;"rrr S : ^ ;-

fil 3.

emetoe 'cr 2:":-

L, e i. ;..;;; with the

  • 7 destelled persi 3 emphant estreser systes.

meste-Sers test este e111 he esteittee to the sac Ser approve 1.

Prior to seek approwel,etese a g.

l a) demetored and shippes

$deWotes will either hos de opproved Righ-Integrity contateere. er b) eeliesti.e my e seh&1. eessor.

-- - -- : a l

m Class on.) C unsk.s na/ %e Class 4 eaks s4sel.it*. Wl red'y 4L but!=/

f SMc 4 a eef +se regaire art r/secn.C/st(4) i she // k Me/ %4te."

l I

L l

l

(

'(

)

i e

s t

av

---m----

.n-enn,-,,,

e-_-,

~.-.

p,gt 4*

FCF Manual Rev y Page 9 et p i

TARLs 14 d

PROCESS PARA M TERS TO a uTLghdhigghedr4/p:$..um ~ *= 7-r-SY

~

rs.Tm -Fna..

gesime/Studees Seoe 2

3 3

4 S

6

?

e 360- 330- 960 330 350- 350- 180 Temperature (*F) 140 man 300 370 330 350 280 380 300

(

Evaoorster Sottoes sone-

.1 2

3 4

5 6

7 e

ISO-330- 360- 330- 350- 350- 320 Temperature (*F) 140 man 300 270 320 350 300 300 370 WASTE /ASPMALT RATIOS

  • Evaporator sottoms i 50/50 f

(

sesins/studges i 80/50 i

LIM 27 DN 03L IN FEED STREAM One percent ASPMALT TYPE seest ASTM D-312-71, Type III

  • The values given in this section are tentative. The preopera-tional test program will determine the high and low ranges of these war'iables for aceoptable oolidifisetion. Finst operatang points and acceptable ranges will them he doeorporated in a revision to this PCF.'

___.___.-m,

_m.,,.,-.--..

.,._._--,,y.,-

,,y-

---.._y-__y

12 Inoperable Effluent Instrumentation The Permi-2 main cordenser off gas hydrogen monitor N62-09-9-900-JA-006 was inoperable for greater than a 30 day period during tha reporting priod fra July 1 through Decuber 30, 1986. Due in part to design and parts problems, this monitor was not returned to service within 30 days.

l t

l l

l O

1 i

U 4

Potential Dose Assessment For the purposes of meeting the requirerents of 19 CPR 20, Permi-2 is required to calculate the dom to an individual in the " unrestricted area" fraa plant

. liquid and gaseous effluents. In IURDG 9133 the term " unrestricted area" is expanded as follows:

any area at or beyond the site boundary access to which is not controlled by the licensee for purposes of protection of individuals from exposure to radiation and radioactive materials, and any area within the site boundary used for residential quarters or industrial, comercial, institutional and recreational facilities."

In this expanded definition, dose to an individual as a member of the public from their activity.in the site boundary is further delineated by Fermi-2 1

Technical Specification. Fermi-2 defines member (s) of the public as follows:

"Hember(s) of the public shall include all persons who are not occuptionally associated with the plant. This category cbes not include employees of the utility, its contractors or vendors. Also excluded from this category are i

persons who enter the site to service equipient or to make deliveries. This category does include persons who use portions of the site for recreational occupational, or other purposes not associated with the plant."

t f

The Fermi-2 site has one area that must be consideral for dose assessaent.

1 This site location is the visitor's center lomted 470 neters in a South Southwest direction from the Reactor centerline. The person raost typically exposed to plant effluent is the adult individual (17 years or older). '1he exposure this person receives is direct exposure (plant ncble gases), and inhalation (H3, I-131,133 and particulates). '1he maximum time the individual is exposed to plant effluents is 4 hours4.62963e-5 days <br />0.00111 hours <br />6.613757e-6 weeks <br />1.522e-6 months <br /> in any one year.

j In the reporting year January 1 through December 31, 1986, the individual at the Visitor's Center was not exposed to quantified plant radioactive effluents as a result of the operation of Fermi-2 2

i i

i l

e

-wat 4

---,.e.w,,ww

- o -me.ww-g+--w sww

,y,%,v,-g,.y.p,,wg-e,--.,

.,wa,y,---g--.g,,

,--mrie.ep.,m%e.,w.p.,gg,,,,,y5,ve--9%,,y.w a g y-ar rT Et

'r*'eN'"'*%w-mygw==.we-,-e,-p-w-*-*~r*

Change to the Offsite Dose Calculation Manual (CDCM)

Enclosure le 4

For the reporting period, July through December 1986, no changes in calculation methodology or Land Use Census were approved for the Offsite Dose Calculation Manual (GXM).

l 1

4 I

(

l l

l

,--r_......_

r.

,,_._.,_.-._..m._

3. Ralph Sylvia Group Vice Presdent Reg. Guide 1.21 10CFR50.36a TC)W se ISOn m;anorinonoesign..y r r a a " ~ ee February 28, 1987 GP-87-0010 U. S. Nuclear Regulatory Commission Attention:

Document Control Desk Washington, D. C.

20555

Reference:

Fermi 2 NRC Docket No. 50-341 Facility Operating License No. NPF-43

Subject:

Semi-Annual Radiolocical Effluent Release Reoort The Semi-Annual Effluent Release Report for Fermi 2 is attached.

This report is being transmitted in accordance with Fermi 2 Technical Specification 6.9.1.8, 10CFR50.36a and Regulatory Guide 1.21, Revision 1.

The attached report covers the period from July 1 through December 31, 1986.

Please direct any questions or requests for additional information to Mr. Lewis Bregni at (313) 586-5313.

Sincerely, 4

cc:

J. G. Keppler W. G. Rogers J. J. Stefano G. C. Wright St+8

</5

U. S. Huclear Regulatory Commission February 28, 1987-GP-87-0010 Page 2 bcc:

F.

E. Agocti R. L. Andersen S. J. Bartaan J.

P.

Bobba L.

P. Bregni R. C. Drouillard O. K..Earle-R.

R.

Eberhardt A. K. Elibe J. II. Flynn S.

R. Frost-F. M. Ghodsi J.

R. Green J. E. Kepus S. J. Latone J. D.

Lenan

~

R.

S. Lenart U. V. Lipton R. A. !!ay L.

Martin J. A.

Myquint U.

S. Orser G. R. Overbeck E. II. Page J.

H.

Plona E.

Procton, Jr.

E.

Prystupa T. Randazzo R. G.

Rateick S.

Savage (MUS)

L. J. Simpkin F. H. Sondgeroth B.

R.

Sylvia G. !!. Trahey U.

II. Tucker C. T. Ueber J. J. Wald D. B. Uehmeyer J. !!. Uianieucki Approval Control Region III Chron File Secretary's Office (2412 UCD)

Licensing File:

SA-1 l

....