ML20204D980

From kanterella
Jump to navigation Jump to search

Proposed Tech Spec Page 3/4 9-16,changing Limiting Condition for Operation Re Spent Fuel Storage
ML20204D980
Person / Time
Site: McGuire, Mcguire  
Issue date: 03/16/1987
From:
DUKE POWER CO.
To:
Shared Package
ML20204C286 List:
References
TAC-60845, TAC-60846, NUDOCS 8703250602
Download: ML20204D980 (1)


Text

-

t 4

3/4.9.12 FUEL STORAGE - SPENT FUEL STORAGE POOL LIMITING CONDITION FOR OPERATION 3.9.12 Fuel is to be stored in the spent fuel storage pool with:

.The boron concentration in the spent fuel pool maintained at a.

greater than or equal to 2000 ppm; and b.

Storage in Region 2 restricted to irradiated fuel which has decayed at least 16 days and one of the following:

1)

Fuel which has been qualified in accordance with Table 3.9-1; MC*Pfy(dg nq 3

2)

Fuel which has been qualified by means of,an analysis to assure ~

w ph o-9 5 *7. pec h iq or a s s '7e cen fidence. le v d *ho+ kfc is DC gr e cii-tr tbon.% int kcl

  • Og a ll u nter PG f n P f CSj C s-3)

Unqualified fuel stored in a checkerboard configuration.

In the event checkerboard storage is used, one row between normal storage locations and checkerboard storage locations will be vacant.

APPLICABILITY:

During storage of fuel in the spent fuel pool.

ACTION:

Suspend all actions involving the movement of fuel in the spent a.

fuel pool if it is determined a fuel assembly has been placed in the incorrect Region until such time as the correct storage location is determined. Move the assembly to its correct location before resumption of any other fuel movement.

j b.

Suspend all actions involving the movement of fuel in the spent fuel pool if it is determined the pool boron concentration is less than 2000 ppm, until such time as the baron concentration is increased to 2000 ppm or greater.

The provisions of Specifications 3.0.3 and 3.0.4 are not applicable.

c.

l SURVEILLANCE REQUIREMENTS l

4.9.12a.

Verify all fuel assemblies to be placed in Region 2 of the spent fuel pool are within the enrichment and burnup limits of Table 3.9-1 or that K,ff < 0.95 by checking the assemblies' design and 1

burnup documentation or the assemblies' qualifying analysis i

documentation respectively.

4 l

8703250602 870316 PDR ADOCK 05000369 I

P PDR f

l l

MCGUIRE - UNITS 1 and 2 3/4 9-16 I

c-.

,,,,,-,,,-,-,,;.,-,