ML20204A175
| ML20204A175 | |
| Person / Time | |
|---|---|
| Site: | Millstone |
| Issue date: | 05/06/1986 |
| From: | Thadani A Office of Nuclear Reactor Regulation |
| To: | Opeka J NORTHEAST NUCLEAR ENERGY CO. |
| References | |
| TAC-60876, TAC-61256, NUDOCS 8605090452 | |
| Download: ML20204A175 (3) | |
Text
.
CS May 6, 1986 D I (o Docket No. 50-336 Mr. John F. Opeka, Senior Vice President Nuclear Engineering and Operations Northeast Nuclear Energy Company P.O. Box 270 Hartford, Connecticut 06141-0270
Dear Mr. Opeka:
Subject:
REQUEST FOR RELIEF FROM INSERVICE TESTING (IST)
REQUIREMENTS FOR MILLSTONE 2 By letter dated February 28, 1986, in response to the staff's letter dated October 31, 1985, you submitted an IST program for the safety-related Emergency Diesel Generator (EDG) auxiliary systems and requests for relief from certain testing requirements.
Although we have not completed our detailed re/iew of your submittal, our preliminary review makes it clear to us that your expanded program increases the scope of inservice testing for the EDG auxiliary systems.
We have concluded that this upgrading of inservice testing for the EDG auxiliaries will further enhance safety.
Based on our preliminary review, we agree with the determination that it is impractical within limitations of the design for you to meet certain of the specified ASME Code requirements and that imposition of those requirements would result in hardships or unusual difficulties.
Therefore, pursuant to 10 CFR 50.55a(g)(6)(i), we hereby grant the relief requested in your February 28, 1986 letter from the inservice testing requirements of the ASME Code until the staff has completed its detailed review or until 6 months from the date of this letter, whichever comes first.
We have concluded that the relief granted-neither significantly increases the probability or consequences of accidents previously considered nor significantly decreases safety margins and therefore does not involve a significant hazards consideration.
Therefore, you are authorized and should proceed to implement your proposed program no later than April 30, 1986.
During the period between now and the date we complete our detailed review of your submittal, you must comply with both your existing Technical Specifications and your proposed inservice testing program for the EDG auxiliaries.
Granting of this relief from ASME Code requirements should not be interpreted to give you relief from any of the requirements in your existing Technical Specifications.
t hk $h336 PDR i
-J
When our detailed review of your submittals is complete we will:
(1) issue final approval of your program (which may contain modifications resulting from the staff's review); and (2) grant relief from any ASME Code ~ requirements that i
are determined to be impractical for your facility for the duration of the inspection interval.
If you have any questions concerning this matter, please contact the
- Millstone 2 Project Manager, D. Osborne.
Sincerely, P
/S/
Ashok C. Thadani, Director PWR Project Directorate #8 Division of PWR Licensing-B 4
i Distribution:
Docket File NRC & L PDRs Branch Files OELD 1
ACRS 10 EJordan JPartlow BGrimes PKreutzer FMiraglia 00sborne AThadani HDenton/DEisenhut TBarnhart 4 ORAS DCrutchfield OPA LFMB
/
Eg *MW D
y-B PWR#8 P #
PWR#8 PKresdzer D
orne;eh Atha ni De FM aglia
/ /86 4 /yf/86 b
/86
/J7/86 j/ /86 t
/
y
.,y
?
l:
r Mr. John F. Opeka Millstone Nuclear Power Station Northeast Nuclear Energy Company Unit No. 2 cc:
Gerald Garfield, Esq.
Mr. Wayne D. Romberg Day, Berry & Howard Superintendent Counselors at Law Millstone Nuclear Power Station City Place P. O. Box 128 Hartford, Connecticut 06103-3499 Waterford, Connecticut 06385 Regional Administrator, Region I Mr. Edward J. Mroczka U.S. Nuclear Regulatory Commission Vice President, Nuclear Operations Office of Executive Director for Northeast Nuclear Energy Company Operations P. O. Box 270 631 Park Avenue Hartford, Connecticut 06141-0270 King of Prussia, Pennsylvania 19406 Mr. Charles Brinkman, Manager Washington Nuclear Operations C-E Power Systems Combustion Engineering, Inc.
7910 Woodmont Avenue Bethesda, Maryland 20814 Mr. Lawrence Bettencourt, First Selectman Town of Waterford Hall of Records - 200 Boston Post Road Waterford, Connecticut 06385 Northeast Utilities Service Company ATTN: Mr. Richard R. Laudenat, Manager Generation Facilities Licensing Post Office Box 270 Hartford, Connecticut 06141-0270 Kevin McCarthy, Director Radiation Control Unit Department of Environmental Protection State Office Building Hartfotd, Connecticut 06106 Mr. Theodore Rebelowski U.S. NRC P. O. Box 615 Waterford, Connecticut 06385-0615 Office of Policy & Management ATTN:
Under Secreury Energy Division 80 Washington Street Hartford, Connecticut 06106