MONTHYEARML20203B0551998-02-10010 February 1998 Recommends That Encl Form Ltr Be Sent to Licensee Indicating Findings of Review of Vallecitos Nuclear Ctr Reactor Facilities Radiological Emergency Plan Project stage: Approval ML20154P8111998-10-20020 October 1998 Forwards RAI Re 970930 Submittal of License Renewal Application for General Electric Co Nuclear Test Reactor at Vallecitos Nuclear Ctr Project stage: RAI ML20212F1601999-09-22022 September 1999 Forwards Notice of Consideration of Application for Renewal of License Being Filed with Office of Fr for Publication. Notice Relates to Licensee Application Dtd 970930,for License Amend to Renew FOL R-33 Project stage: Other 1998-02-10
[Table View] |
|
---|
Category:INTERNAL OR EXTERNAL MEMORANDUM
MONTHYEARML20210T6011986-02-12012 February 1986 Submits Daily Staff Notes.Region Iii,Nrr & Cleveland Electric Illuminating Co Will Meet on 860211 Onsite to Discuss Reviews Re 860131 Earthquake Near Site & Readiness of Plant for Fuel Loading ML20126H2591981-04-0606 April 1981 Forwards Addl Copies of NRC 810403 Response to Intervenor Dellums Request for Production of Documents.W/O Encl ML20151B3451980-10-0606 October 1980 Forwards Overview of Geosciences Branch Workload,W/Priority Indicated.Requests Assistance W/Scheduling ACRS & Hearings ML20148B8491980-01-10010 January 1980 Notification of 800129 Meeting W/Ge & Consultants in Bethesda,Md to Discuss Presentation of Licensee Probability Analysis ML20147C5581978-12-13013 December 1978 Forwards Status Rept of Dse Review of Geology as It Relates to Potential for Surface Faulting of Getr Site.Data Is Incomplete & Does Not Allow Final Conclusions.Encl Request for Addl Info ML20147H7361978-12-0505 December 1978 Corrects Error in NRC Staff Answer to Intervenors' Request for Referral & Licensee'S Motion for Imposition of Sanctions, Dtd 781129.On p2 Denied Should Read Granted. Staff Supports Licensee'S Request to Impose Sanctions ML20147C4721978-11-27027 November 1978 Notice of 781205 Visit to Facil in Order to Inspect Trenches Completed in the Getr Site Fault Investigation ML20147C8621978-02-0303 February 1978 Forwards 780201 USGS Review of Potential Faulting at Subj Site.Feels Staff Should Not Take Firm Position Until After Its Review.W/Encl ANO:7809250067 ML20147C8701978-01-0909 January 1978 Identifies Sys Which Are Req to Assure Adequate Core Cooling, & Specifies Operability Conditions That Must Be Met by Each Sys ML20147C9411977-12-14014 December 1977 Summary of 771202 Meeting Re Geological & Seismological Matters Relating to Seismic re-evaluation of Getr. Requests That Facility Provide Info Re Surface Faulting in Support of 771024 Show Cause Order.W/List of Attendees ML20147D3651977-11-30030 November 1977 Discusses Status of Trench Closing at Vallecitos & Examination of Trenches by NRC & Other Agencies.Recommends That GE Be Allowed to Backfill Trenches 1,2 & 3 & the Large Boreholes Now Dug,W/Encl Comments for 771202 Getr Meeting ML20147D2141977-11-10010 November 1977 Requests Dor Provide Proposed Fed Register Notice Repting Shutdown of Getr as Abnormal Occurrence.W/Encl Copy of Previous FRN for Abnormal Occurrence for Info ML20147C5611977-10-28028 October 1977 Forwards Rept on Status of Assessment of Geology & Seismology at Getr Site, ML20147C7631977-10-27027 October 1977 Notice of Meeting W/Ge on 771029 to Provide Info to Justify Resuming Oper of Getr ML20147D2111977-10-26026 October 1977 Notification of 771028 Meeting in Bethesda W/Ge to Allow GE to Give NRC Its Assessment of All NRC-lic Activities at Vallecitos,As Req by 771024 Show Cause Order ML20147D3441977-10-25025 October 1977 Summarizes 771024 Conversation W/Ge & Consultants to Determine Ge'S Plans for Further Investigations of Faulting Near Vallecitos Facil & Status of Investigations ML20147C8061977-10-0404 October 1977 Discusses Rereview Re Ability to Cool Core Assuming Cooling Water Absence of Full Seismic Design Capability.Because of Various Assumptions,Staff Must Have Reasonable Assurance of Items Withstanding Seismic Forces ML20147E5761977-10-0404 October 1977 Requests That Geology & Seismology Branch Provide Tech Assistance to Div of Operating Reactors in the Geology & Seismology Review of the Subj Facil as Discussed in Enclosed TAC 7062.W/o Encl ML20147C6211977-09-15015 September 1977 Summarizes 770803 Meeting Re Discussion of Seismic Reeval of Subj Facil.Concluded That Addl Info Re Site Seismic & Geologic Info Is Needed from Gen Elec ML20147C8161977-09-15015 September 1977 Summarizes 770831 Briefing on Gen Elec'S Phase I Geological Investigation Which Presented a New Map of Livermore Valley & Interpreted the Geology & Seismology of Area Around Greenville & Las Positas Faults ML20147C6111977-09-12012 September 1977 Reports on Briefing by D Herd Re Detailed Field Mapping That Has Identified a Number of Faults W/Relatively Young Geological Movement Near Subj Facil ML20147C7821977-05-0606 May 1977 Forwards Form Reply Sent in Response to Pub Inquiries Re Pending Lic Renewal Appls.Forwards Mailing List for Notices to Be Issued on Renewal Appls ML20147C7981977-05-0606 May 1977 Forwards Draft Ltr Outlining NRC Review Process as Background Info for Getr Review.Requests Comments 1986-02-12
[Table view] Category:MEMORANDUMS-CORRESPONDENCE
MONTHYEARML20210T6011986-02-12012 February 1986 Submits Daily Staff Notes.Region Iii,Nrr & Cleveland Electric Illuminating Co Will Meet on 860211 Onsite to Discuss Reviews Re 860131 Earthquake Near Site & Readiness of Plant for Fuel Loading ML20126H2591981-04-0606 April 1981 Forwards Addl Copies of NRC 810403 Response to Intervenor Dellums Request for Production of Documents.W/O Encl ML20151B3451980-10-0606 October 1980 Forwards Overview of Geosciences Branch Workload,W/Priority Indicated.Requests Assistance W/Scheduling ACRS & Hearings ML20148B8491980-01-10010 January 1980 Notification of 800129 Meeting W/Ge & Consultants in Bethesda,Md to Discuss Presentation of Licensee Probability Analysis ML20147C5581978-12-13013 December 1978 Forwards Status Rept of Dse Review of Geology as It Relates to Potential for Surface Faulting of Getr Site.Data Is Incomplete & Does Not Allow Final Conclusions.Encl Request for Addl Info ML20147H7361978-12-0505 December 1978 Corrects Error in NRC Staff Answer to Intervenors' Request for Referral & Licensee'S Motion for Imposition of Sanctions, Dtd 781129.On p2 Denied Should Read Granted. Staff Supports Licensee'S Request to Impose Sanctions ML20147C4721978-11-27027 November 1978 Notice of 781205 Visit to Facil in Order to Inspect Trenches Completed in the Getr Site Fault Investigation ML20147C8621978-02-0303 February 1978 Forwards 780201 USGS Review of Potential Faulting at Subj Site.Feels Staff Should Not Take Firm Position Until After Its Review.W/Encl ANO:7809250067 ML20147C8701978-01-0909 January 1978 Identifies Sys Which Are Req to Assure Adequate Core Cooling, & Specifies Operability Conditions That Must Be Met by Each Sys ML20147C9411977-12-14014 December 1977 Summary of 771202 Meeting Re Geological & Seismological Matters Relating to Seismic re-evaluation of Getr. Requests That Facility Provide Info Re Surface Faulting in Support of 771024 Show Cause Order.W/List of Attendees ML20147D3651977-11-30030 November 1977 Discusses Status of Trench Closing at Vallecitos & Examination of Trenches by NRC & Other Agencies.Recommends That GE Be Allowed to Backfill Trenches 1,2 & 3 & the Large Boreholes Now Dug,W/Encl Comments for 771202 Getr Meeting ML20147D2141977-11-10010 November 1977 Requests Dor Provide Proposed Fed Register Notice Repting Shutdown of Getr as Abnormal Occurrence.W/Encl Copy of Previous FRN for Abnormal Occurrence for Info ML20147C5611977-10-28028 October 1977 Forwards Rept on Status of Assessment of Geology & Seismology at Getr Site, ML20147C7631977-10-27027 October 1977 Notice of Meeting W/Ge on 771029 to Provide Info to Justify Resuming Oper of Getr ML20147D2111977-10-26026 October 1977 Notification of 771028 Meeting in Bethesda W/Ge to Allow GE to Give NRC Its Assessment of All NRC-lic Activities at Vallecitos,As Req by 771024 Show Cause Order ML20147D3441977-10-25025 October 1977 Summarizes 771024 Conversation W/Ge & Consultants to Determine Ge'S Plans for Further Investigations of Faulting Near Vallecitos Facil & Status of Investigations ML20147C8061977-10-0404 October 1977 Discusses Rereview Re Ability to Cool Core Assuming Cooling Water Absence of Full Seismic Design Capability.Because of Various Assumptions,Staff Must Have Reasonable Assurance of Items Withstanding Seismic Forces ML20147E5761977-10-0404 October 1977 Requests That Geology & Seismology Branch Provide Tech Assistance to Div of Operating Reactors in the Geology & Seismology Review of the Subj Facil as Discussed in Enclosed TAC 7062.W/o Encl ML20147C6211977-09-15015 September 1977 Summarizes 770803 Meeting Re Discussion of Seismic Reeval of Subj Facil.Concluded That Addl Info Re Site Seismic & Geologic Info Is Needed from Gen Elec ML20147C8161977-09-15015 September 1977 Summarizes 770831 Briefing on Gen Elec'S Phase I Geological Investigation Which Presented a New Map of Livermore Valley & Interpreted the Geology & Seismology of Area Around Greenville & Las Positas Faults ML20147C6111977-09-12012 September 1977 Reports on Briefing by D Herd Re Detailed Field Mapping That Has Identified a Number of Faults W/Relatively Young Geological Movement Near Subj Facil ML20147C7821977-05-0606 May 1977 Forwards Form Reply Sent in Response to Pub Inquiries Re Pending Lic Renewal Appls.Forwards Mailing List for Notices to Be Issued on Renewal Appls ML20147C7981977-05-0606 May 1977 Forwards Draft Ltr Outlining NRC Review Process as Background Info for Getr Review.Requests Comments 1986-02-12
[Table view] |
Text
_ _ _ _ - _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ - _ _ _ _ - _
February 10, 1998 e
MEMORANDUM TO: Marvin M.Mendonza, Senior Project Manager Non Power Reactors and Decommissioning Branch Division of Reactor Program Management Office of Nuclear Reactor Regulation FROM: Barry Zaleman, Acting Chief Original sigmd by:
Emergency Preparedness and Environmental Falk Kant.or for:
Health Physics Section Emergency Preparedness and Radiation Protection Branch Division of Reactor Program Management Office of Nuclear Reactor Regulation
SUBJECT:
REVIEW OF THE VALLECITOS NUCLEAR CENTER REACTOR FACILITIES RADIOLOGICAL EMERGENCY PLAN, (TAC NO. MA 0099)
In response to your request, the Emergency Preparedness and Environmental Health Physics Section (EP&EHP) reviewed the changes to the Vallecitos Nuclear Center Reactor Facilities Radiological Emergency Plan, revised in October 1997. The plan changes in this revision were submitted in a letter dated November 5,1997, from B.M. Murray, Senior Licensing Engineer, Vallecitos Nuclear Center. The licensee indicated that these changes did not decrease the effectiveness of the emergency plan, i n The October revision covers the emergency classification system and the emergency action levels. The revision 'ncorporates the changes discussed in the revised Appendix l to NUREG '184g, dated April 1997. Our initial review confirms that the licensee properly submitted these changes under 10 CFR 50.54 (a) and the changes do not decrease the effective of the plan.
We recommend that the following attached form letter be sent to the licensee indicating our finoings. This letter is part of a Draft Emergency Preparedness Position on Emergency Plan and implementing Procedure Changes ( EPPOS No 4). ,/l Docket Nos. 50-73
Attachment:
As stated:
hb
Contact:
Lawrence K. Cohen, NRR/PERB 415-2923 DISTRIBUTION JRoe LCohen sDechetMoD CMiller PEtRB Reading PUBLIC BZatcman NPR reading file DOCUMENT NAME: G:\LKC\VNC.REV To toer%e a copy of this docume.n, tr.dcate in the bou- "C" = Cooy wviout attachment' enclosure "E' = Copy wth attachment! enclosure *N* = No copy OFFICE NRR.PERB /) l t[. SC:PERB,g lE l l l NAME LCohen /, \ BZahmac( / '
- ~ '
DATE 02/N /98 ~\ 02/f6/98 l OFFICIAL RECORD COPY 9002240194 980210 PDR ADOCK 05000073 F PDR _
{., m g ,gjg 7 y,q;,,
I,I! (l! (l.ll II,l! ,, ,dll ll
_ 1
, February 10, 1998 MEMORANDUM TO: Marvin M.Mendonza, Senior Project Manager Non Power Reactors and Decommissioning Branch Division of Reactor Program Management Office c' Nuclear Reactor Regulation FROM: Barry Zaleman, Acting Chief original signed by:
Emergency Preparedness and Environmental Falk Kantor for:
Health Physics Section Emergency Preparedness and Radiation Protection Cranch Division of Reactor Program Management Office of Nuclear Reactor Regulation
SUBJECT:
REVIEW OF THE VALLECITOS NUCLEAR CENTER REACTOR FACILITIES RADIOLOGICAL EMERGENCY PLAN, (TAC NO. MA 0099)
In response to your request, the Emergency Preparedness and Environmental Health Physics Section (EP&EHP) reviewed the changes to the Vallecitos Nuclear Center Reactor Facilities Radiological En ergency Plan, revised in October 1997. The plan changes in this revision were submitted in a letter dated November 5,1997, from B.M. Murray, Senior Licensing Engineer, Vallecitos Nuclear Center. The licensee indicated that these changes did not decrease the effectiveness of the emergency plan.
The October revision covers the emergency classification system and the eme,1ency action levels. The revision incorporates the changes discussed in the revised Appendix 1 to NUREG-0849, dated April 1997. Our initial review confirms that the licensee properly submitted l
- hese changes under 10 CFR 50.54 (q) and the changes do not decrease the effective of the plan.
We recommend that the following attached form letter be sent to the licensee indicating our findings. This letter is part of a Draft Emergency Preparedness Position on Emergency Plan and Implementing Procedure Changes ( EPPOS No 4).
Docket Nos. 50-73
Attachment:
As stated:
Contact:
Lawrence K. Cohen, NRR/PERB 415 2923 DISTRIBUTION JRoe LCohen Docket File CMiller PERB Reading PUBLIC BZaleman NPR reading file DOCUMENT NAME: G:\LKC\VNC.REV n ...ov. . e.,y onm. exo .m. inac... m ,,,. 6.c e . con, .ew, .n.cwne.noom. r - cecy we n.eww noew. r - No eooy sC:PERB,g l E.
' OFFICE NRR PERB /) l6 l l l NAME LCohen /, ( RZalemag / '
DATE O2/V3 /98 ~\ o2/l6/98 OFFICIAL RECORD COPY
p* CEOvq y *, UNITED STATES NUCLEAR REGULATORY COMMISSION
- f WASHINGTON, D.C. Sc66H001
%, # February 10, 1998 MEMORANDUM TO: Marvin M.Mendonza, Senior Project Manager Non-Power Reactors and Decommissioning Branch Division of Reactor Program Management Office of Nuclear Reactor Regulation FROM: Barry Zaleman, Acting Chief Emergency Preparednese and Environment J [.&v Health Physics Section Emergency Preparedness and .
Radiation Protection Branch Division of Reactor Program Management Office of Nuclear Reactor Regulation
SUBJECT:
REVIEW OF THE VALLECITOS NUCLEAR CENTER REACTOR FACILITIES RADIOLOGICAL EMERGENCY PLAN, (TAC NO. MA 0099)
In response to your request, the Emergency Preparedness and Environmental Health Physics Section (EP&EHP) reviewed the changes to the Vallee!'os Nuclear Center Reactor Facilities Radiolegical Emergency Plan, revised in October 1997. The plan changes in this revision were submitted in a letter dated November 5,1997, from B.M. Murray, Senior Licensing Engineer, i Vallecitos Nuclear Center. The licensee indicated that these changes did not decrease the effectiveness of the emergency plan.
The October revision covers the emergency classification system and the emergency action levels. The revision incorporates the changes discussed in the revised Appendix I to NUREG-0849, dated April 1997. Our initial review confirms that the licensee properly submitted these changes under 10 CFR 50.54 (q) and the changes do not decrease the effective of the plan.
We recommend that the following attached form letter be sent to the licensee indicating our findings. This letter is part of a Draft Emergency Preparedness Position on Emergency Plan and Implementing Procedure Changes ( EPPOS No 4).
Docket Nos. 50-73
Attachment:
As stated:
Contact:
Lawrence K. Cohen, NRR/PERB 415-2923
Enclosure 1 Attachment 1 EPPOS No 4 Sample letter for Emergency Plan changes which do not appear to decrease effectiveness
SUBJECT:
EMERGENCY PLAN CHANGES This letter acknowledges receipt of your letter dated . which transmitted changes to the Emergency Plan for the ,
submitted under the provisions of 10 CFR 50.54(q).
Based on your determinations that the changes do not decrease the effectiveness of your emergency plan, and that it continues to meet the requirements of Appendix E to Part 50, NRC l
approvalis not required. Our initial review of these changes indicates them to be in accordance with 10 CFR 50.54(q). Implementation of these changes will be subject to inspection to confirm that they have not decreased the effectiveness of your emergency plan, in accordance with 10 CFR 2.790 of the Commission's regulations, a copy of this letter will be placed in the NRC Public Document Room.
Sincerely, Docket No.: