Forwards Review of Structural Design of Polyethylene High Integrity Containers
ML20195G455
Person / Time
Issue date: 06/15/1988
From: Tokar M
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Parry S
NRC ADVISORY COMMITTEE ON NUCLEAR WASTE (ACNW)
Shared Package
ML20151C617 List:
References
FOIA-88-470 NUDOCS 8811230392
Download: ML20195G455 (1)


Text

_

y/Y UNITED STATES

)

NUCLEAR REGULATORY COMMISSION g

t 3*

W ASHINOTO N. D. C. 206S$

%*v Ji#i 151988 MEMORANDUM FOR:

Sidney J. Parry, Senior Fellow Advisory Connittee on Nuclear Waste FROM:

Michael Tokar, h : tion let.dcr Technical Branch Division of Low Level Waste Management and Decommissioning, NMSS

SUBJECT:

REPORT ENTITLED, "REVIEW 0F THE STRUCTURAL DESIGN OF POLYETHYLENE HIGH INTEGRITY CONTAINERS."

The rePcrt develored for the Division of Low-level Waste Management and Decomissioning entitled, "Feview of the Structural Design of Polyethylene High Integrity Containers," is enclosed. We will be discussing ti,e report at the sneetir.g of the Advisory Comittee on Nuclear Waste to te held on June 27 and 28, 1988.

Also enclosed are additional materials relating to High Denaity Polyethylene (HDFE) High Integrity containers (HICs) and the review of HDPE HIC,Iopical Reports which are referenced in the report.

If you have any questions, please contact r4 at x20590.

Michael Tokar, Section Leader Technical Branch Divisien of Low-Level Waste Management and Decoemissioning, HMSS

Enclosures:

As Stated I

es1T2[0592s81115 B&dA g70 PDR v

RE: F0!A-88-470 APPENDIX B (Continued)

RECORDS MAINTAINEO IN THE PDR UNDER THE ABOVE REQUEST NUMBER 18, 6/1988 Presentation handout for AChW meeting - High Density Polyethylene (HDPE)HighIntegrityContainer(HIC) Regulatory Issues.

(9 pages) 19, 6/9/88 Memorandum frcm Widmayer to Surmeier.

(16 pages) t

20. 6/15/88 Memorandum from Tokar to Parry.

(36pages) 21, 6/23/88 Report - Effects of Chemical and Gama Irradiation Environments on the Mechanical Properties of High-Density Polyethylene (HDPE)

(27 pages)

(

22, 6/27/88 Federal Register Notice - Advisory Comittee ch Nuclear Waste -

NRC - Meeting Agenda - Revision 1.

(2pages) 23, 6/28/88 Menorandum from Tokar to Sumeier.

(2pages) 74 6/28/88 Letter from Nussbaumer to Ingersoll.

(20pages) l

25. 6/28/88 NRC Staff Presentation to the ACNW, (38pages) 4 26, 6/28/88 Presentation - Review of the Structural Designs of Polyethylene High Integrity Containers.

(19pages) 27, 7/19/88 Memorandum from Hussbaumer to Knapp.

(3pages) 28, 8/1988 Low-level Waste Package and Engineered - Barrier Study-April -

June 1988 (45 pages)

29. 8/31/88 Memorandum from Sumeier to Nussbaumer.

(36pages) 30, 9/1/88 Menorandum fron Parry to ACNW Members.

(54 pages)

I

31. 9/5/88 Hand Calculations for HPDE HIC 300-year Dose Evaluation.

(17

[

pages)

32. 9/8/88 Memorandum from Stella to Moeller, et al.

(4 pages)

33. 9/12/88 Note from Grim to LLWM Staff. (14 pages)

[

34. 9/12/88 Letter from House to Parry.

(32pages)

35. 9/13-Portion of mes F..g notebook of the Fourth Heeting of the 14/88 Advisory Comittee on Nuclear Waste.

(3pages)

RE: F0!A-88-470 APPENDIX B (Continued)

RECORDS MAINTAINED IN THE POR UNDER THE ABOVE REQUEST NUMBER 36, 9/16/88 Letter frem Moeller to Zech..(2 pages) 37.

9/16/88 Letter from Lubenau to Shealy.

(4 pages)

38. 9/24/88 Memorandum from Moeller to Stella.

(1page)

39. Undated Report - Effects of Chenical and Gama Irradiation Environtents on the Mechanical Properties of High-Density Polyethylene (HOPE).

(17 pages)

40. Undated NRC Staff Coments on the Draf t Report Entitled "Review of the Structural Design of High Integrity Containers".

(2pages)