ML20151M115

From kanterella
Jump to navigation Jump to search
Forwards Amends 111 & 100 to Licenses DPR-39 & DPR-48, Respectively,Safety Evaluation & Technical Evaluation Rept. Amends Allow Steam Generator Tubes to Be Repaired Utilizing Westinghouse Mechanical Sleeving Methodology
ML20151M115
Person / Time
Site: Zion  File:ZionSolutions icon.png
Issue date: 04/06/1988
From: Norris J
Office of Nuclear Reactor Regulation
To: Butterfield L
COMMONWEALTH EDISON CO.
Shared Package
ML20151M120 List:
References
NUDOCS 8804220242
Download: ML20151M115 (3)


Text

_ _ ___ . _ _

N April 6, 1988 Docket Nos. 50-295 and 50-304 Distribution:-

' Docket File ACRS(10)

PDIII-2 r/f GPA/PA Mr. L. D. Butterfield, Jr. NRC/ Local PDRs PDIII-2 plant file Nuclear Licensing Manager GHolahan HConrao Comonwealth Edison Company Lluther P. O. Box 767 JNorris Chicago, Illinois 60690 OGC-Rockville

Dear Mr. Butterfield:

The V. S. Nuclear Regulatory Commission has issued the enclosed Amendment i No.lll to Facility Operating License No. DPR-39 and Amendment No.100 to  !

Facility Operating License NPF-48 for the Zion Nuclear Power Station, Units 1 and 2, respectively. The amendments consist of changes to the Technical Specification in re.,ponse to your application transmitted by letter dated December 24, 1987 and nodified February 11, 1988.

These amendments allows steam generator tubes to be repaired by utiliziilg Westinghouse mechanical sleeving methodology.

A copy of the related Safety Evaluation is enclosed. A Notice of Istuance will be included in the Connission's biweekly Federal Register notice.

Sincerely, Jan A. Norris, Project Manager

Project Direu. orate 111-2 .

Division of Reactor Projects - III IV, V and Special Projects

Enclosures:

I. Amendment No.lli to License Nc. DPR-39

2. Amendtrent No.100 to License No. DPR-48
3. Safety Evaluation cc w/ enclosure:

See next page

] (

(F

.P'Ih.PM

/J orrii' bj PDIII-2:LA LLuther A FDQ D%1 er

'D

[t/[L(,

p 3 //f/88 j /// /88 8 y bi 1 8804220242 080406 /

DR ADOCK 050 5 (,

1 i

i

j--

'kg UNITED STATES NUCLEAR REGULATORY COMMISSION I ' WASHINGTON, D. C. 205$5

  • 5 j

\

%.....] April 6, 1988 Docket Nos. 50-295 and 50-304 Mr. L. D. Butterfield, Jr. i Nuclear Licensiag Manager t Comonwealth Edison Company P. O. Box 767 Chicago, Illinois 60690

Dear Mr. Butterfield:

i The U. S. Nuclear Regulatory Comission has issue 1 the enclnsed Amendment No.111 to Facility Operating License No. DPR-39 ard Amendrnent No.100 to 1

Facility Operating License NPF-48 for the Zion Nuclear Power Station, Units 1 ana 2, respectively. The amendments consist of char.qes to the Technical Specification in response to your application transmit +.ed by letter dated December 24, 1987 and modified February 11, 1988.

These amendments allow steam generator tubes to be repaired by utilizing Westinghouse mechanical sleeving methodology.

A copy of the related Safety Evaluation is enclosed. A flotice of Issuance will t.e included in tha Comission's biweekly Federal Register notice.

Sincerely, n '

M.

Oi J A. Norris, Project Manager Pr ect Directorate III-2 I Div sion of Reactor Projects - III IV, V and Special Projects  !

Enclosures:

1. Amendmen' No,111 to License No. DPR-39
2. Arrendment No.100 to License No. DPR-48
3. Stfety Evaluation cc w/enclosurc:

See nex: page l

I

)

, Mr. L. D. Butterfield, Jr.

Commonwealth Edison Company Zion Station CC: Mr. Michael C. Parker, Chief Robert J. Vollen. Esq.

Division of Engineering 109 N. Dearborn Street Illinois Department of Nuclear Chicago, Illinois 60602 Safety Dr. Cecil Lue-Hing 1035 Outer Park Drive, 5th Floor Director of Research and Development Springfield, Illinois 62704 Metropolitan Sanitary District of Greater Chicago 100 East Erie Street Chicago, Illinois 60611 Phillip Steptoe, Esq. J Sidley and Austin One First National Plaza Chicago, Illinois 60603 Mayor of Zion Zion Illinois 60099 Illinois Department of Nuclear Safety ATTN: Manager, Nuclear Facility Safety 1035 Outer Park Drive 5th Floor Springfield, Illinois 62704

  • U.S. Nuclear Regulatory Comission Resident Inspectors Office 105 Shiloh Blvd.

Zion, Illinois 60099 Regional Administrator, Region III U.S. Nuclear Regulatory Comission 799 Roosevelt Road Glen Ellyn, Illinois 60137

- _ _ _ _ _ _ - _ _ _