Forwards Util Transmitting Change Request 3 to TS for Facility
ML20141L045
Person / Time
Site: Oyster Creek
Issue date: 04/25/1972
From: Skovholt D
US ATOMIC ENERGY COMMISSION (AEC)
To: Siess C
Advisory Committee on Reactor Safeguards
Shared Package
ML20091A092 List: ... further results
References
FOIA-91-282 NUDOCS 9203260296
Download: ML20141L045 (2)


Text

- . - . . . .

( \

[ "**,,* UNITED STATES I

' -Q' J L

') - ' '

ATOMIC ENERGY COMMISSION was4Norow, o.c. ros4i's'

%;* 1 %)

"'; .E'YlO

%,(( p #' April 25, 1972 4

E" Docket No. 50-219 2 33 0.YbRim;..J(jfjCM

-m s4rc fu Er, Chester P. Siers Chaircan, Advisc."/ Co. T .ittee en Reacter Safeguards

. U. S. Ator.ic Energy Co-* "' m Washirgten, D c. 205L5 i

! Ieu'Er. Siess:

Sixteen (16) copies cf the following are transr.itted fcr the l Cox.ittee's information:

Letter from Jersey Central Power & I.ight Company dated April 19, 1972, transmitting Facility Change Request No. 3 to the Technical Specifications for the Oyster Creek Nuclear Generating Station.

Letter from Jersey Central Power & Light Company

dated April 20, 1972, reporting an incident that occurred on 4/11/72 when Reactor Building Ventilation 1 System failed to close at the Ovster Creek Nuclear Generating St
tion.

l Sincerely, I

f// ,dho/df Donald J. Skovholt Assistant Director for Reactor Operaticra

! Division of Reactor Licensing

Enclosures:

l As stated

- , r :y u

\ h,i h.s t;

~'

l

  • k g.} r [ ~5 l' ,

bbD Vd y ayb h,,

fe ' ,,

sj j 9203260296 910807  !, , '1

'f<

PDR FOIA _

f DEKOK91-282 PDR )

J

- . - - . . . .... ~ ~ - . - - . . - - .-- _ . _-

/ ,

, ( 1 ,

I 1 ~

, e SUFFLZMENT NO.1$3 CATECOET 8 Oyster Crook May 4, 1972 WRS Type III Fuel Dundles .

6 ACES Jersey Central Power 6 1,11ht Coe948Y letter dated Aeril 19. 1972 forwards Facility Chag e Request No. 3 requesting authorisation to load and operate the reacter more in a eenfiguration described tr the basi: decessen t . N major change is the addittee of four

, Type III fuel bundles which are described in the basic document, i

N eore leading would sonsiet of 132 fresh Type II bundle, 4 i j mew Type III assemblies, 24 Type II bundles that were inserted '

in the fall of 1971 and 400 Type I bundles from the original sere.

l '

the Type III bundles will be the same bundle everage enrichment as the Type II bundles. N lee enrichment rods will have a somewhat higher. antichment and the mediuse-low enrichment region will bn eliminated. N Type III bundles will be prorided by Jorsey Wuclear. The initial reactivity of Type III fuel is 0.06 - 0.074 k greater than for Type 11 but has only a small effect on the overall core characteristies.

The calculated peak clad towperature using the Istaria SCC 8 Criteria calculations is 22250T.

No ACES action is recsammended.

l The enclosed material should be retained as part of the permanent record.

l Ocm o,

OrrICE > ... ,h .. . . . . . . . . . . .. .. . . . . . . . .

SURNAME > . .. . .. . . . . . . . .. . .

DATE> ,, . 7.h.. _. . . . . .. . .. . . . . . . . . . . . .

I Form AEC-315 (Rev. 9 53l AECM 0240 **o sis-to-eles.s i m-e rs g

- .- . - - . - - - _ .- - - . _ _ .