January 14, 1971 Wt,.i f ul W. R. Stratton, Chairman Oyster Creek Subcosaittes C. P. Stess, Vice Chairman, ACKS CATE00RY B REPORTS - OYET1ER CRREX JERSEY CKWRAL POWER & LICifT i
COMPANY LETTER MTED DECEMBER 23, 1970 AND DRL LETTER DATED JANUARY 3, 1971 Attached is a brief eumary of the information presented in the subject correspondenen. No ACRS action appears warranted.
The6e itees should be incorporeted in your set of project docussents to maintain an up-to-date description of the plant, organisation, pro-eedures, etc.
Dricinta Signed by J. C.1;cKinley I
j J. C. 14cKinley 8
Staff Assistant
}l Attachments:
- 1) Summary i
c
- 2) Jersey Central Power 4. Light I
Co 1tr dtd 12/23/70
- 3) DRL ltr dtd 1/5/71 l
l l
l l
a 1
omet >
.. ACRS..
..]..
L EURNAME>
..dh.DI.hhh...
oAn >
..m
=
_,x........
9203260053 910007 E r/"t l
(
DEh0K91-282 PDR v
a e>?
'kY-y..
OTSTER CLIEK Jersey Central power & 1.tsht Castpany letter dated i ~ i.
Deeeisber 13. 1970 reporte the 1 allure ef betk torius n'9 vacuum breskar block valves to operata en test.
$4 4 The Terus to reactor Wilding vuvum breaker, air.
operated, butterfly-type, block valves were being tested as part of the routine surveillance program for this aquipment. When a pressure of 0.4 peig was applied to the reactor Wilding stee of the dit f orential pressure evitch, neither valve opened i
as required.
?
Yhe cause of failure appears to be insproperly adjusted operating link.asee and some ruet on a thrust plate. Af ter cleaning and sidjustment satisf actory operation was again obtained. The test frequency has been increased to reestablish coniidence in the performance of these valves.
i No ACRS action appears warranted.
DRt. l e t t e r da t e d J er.u ary 3. 1971 a ppr ove s Chang e No. 2 to the Technical Spectiteations which will allow the control rod withdravel prohibit functions to be per f orr.ed by either the Interwdiate Range or Source g stems during rasetor startup.
Range Monitoring y
Ho ACRS action appears warranted.