ML20141K860
Text
_. _ _ _.. _ _... _ _. _.. _ _ _. _. _ _
137 f
t g
y October 20, 1970 f : 'I Peter A. Morris, Director Division of Reactor Licensing OYSTER CREEK During its 126th meeting the ACES sonsidered the application by Jersey Central to increase the maximum power level of. the Oyster l
Creek station from 1600 to 1690 MWt. At the conclusion of that ll meeting the applicant was informed that the Committee was unable
)
to render a decision. To aid the Comaittee in this review, the Regulatory Staff is requested to prepare a brief eupplemental report evaluating the adequacy of the cu rent emergency cerce ecol--
.ing capabilities of the_0yster Creek Station utilizing current
- experimental information and analysis. The evaluation should include peak and average fuel clad temperatures at the time core
-spray is initteted and the highest peak and everage clad temperatures predicted for_the accident. It would be useful to have a curve showing the percentage of the core that exceeds a given temperature
-(temperature vs _ percent of fuel clad).
In addition.to-the-supplemental report the Regulatory Staff should
- be prepared to discuss. the applicability of recent TLECHT test L_p resul.*,sto Oyster Creek, how the level sweli phenomenon appites, how the fire. protection system could be utilised for core cooling,
~ and _how actual liquid redwaste releases compare to -technical 5,ecif t-cation limits. _ It will also be helpful to review the -considerations that' led to the decision to not install a third diesel generator.
TheLCommittee recognises _that the Regulatory Staff will be pressed for time to complete a report covering these points and it will be l
~ satisf actory if the report is available to the Comunittee by November
,]
10.-1970.
g A Suh..oenittee meeting is scheduled for Wednesday, November 11, 1970.
A.echedule and agenda will be - forwarded tc you later.
__ j
\\; '
Original Sigosql R. F. Fraley
- l. [
R. F. Frr.Tey g p',,7 Executive Secretary
,,i.g p A v
.gg m -
r.
g,f f f e.,,
. e Ft. led: Oyster Creek Record Kate: Based on discussions 2sith 4
and ucud.ic 10/19/70.'
~~' : *
^
ouva un i
.. ACRS omer >
. TC.g:.8dR.FF:bj...
M i
m g,;
h(
t t
wer,.
u,s sovtanuent renemns caruz de-o messe
.N m W 415(R.v.D.68)
J l
b 9203250330 910807 PDR FDIA Mb f ng P'*
DEKOK91-282 PDR p4 a
.