January 15 1986 0

Docket No. 50-267 Mr. R. F. Walker, President Public Service Company of Colorado Post Office Box 840 Denver, Colorado 80201

Dear Mr. Walker:

SUBJECT:

COMPLIANCE WITH IE BULLETIN 80-11, ITEMS 2(b) AND 3 Based upon the additional information provided by your staff by letters dated March 1 and July 16, 1985, we have completed our review of your implementation of IE Bulletin 80-11, Items 2(b) and 3, for the safety-related masonry walls not covered in our initial safety evaluation dated October 18, 1983. The results of our review are contained in the j

enclosed supplementary safety evaluation.

We have concluded that the safety-related masonry wall design of the 4

remaining walls is adequate and, therefore, Items 2(b) and 3 of IE Bulletin i

80-11 are now fully implemented for all safety-related walls at the Fort St. Vrain Station.

If you have any question or comments, please contact Kenneth Heitner, our l

project manager for your facility, at (301) 492-7364.

J I

Sincerely, l

}

Original signed by Herbert N. Berkow, Director Standardization and Special j

Projects Directorate Division of PWR Licensing-B

Enclosure:

i As stated cc w/ enclosure:

i See next page DISTRIBUTION:

1 I N PNoonan l

NRC PDR~~"

JDosa Local PDR KHeitner DCS 0 Lynch NSIC HBerkow SSPD Reading

-)ut ofL

~

U- :SSPD

SSPD DPWRL-B:SSPD DWP L-B:SSPD DPWRLp5:)SPD

'dn'an : a c KHeitner OLyngh HBervdw

//9/86 0 lj/86 01/tef786 01/h/86 01/p/86 i

9601220402 860115 gDR ADOCK O g7

f UNITED STATES NUCLEAR REGULATORY COMMISSION E

o D

cE WASHINGTON, D. C. 20555

~s

/

January 15, 1986 Docket No. 50-267 Mr. R. F. Walker, President Public Service Company of Colorado Post Office Box 840 Denver, Col]rado 80201

Dear Mr. Walker:

SUBJECT:

COMPLIANCE WITH IE BULLETIN 80-11, ITEMS 2(b) AND 3 Based upon the additional information provided by your staff by letters dated March 1 and July 16, 1985, we have completed our review of your implementation of IE Bulletin 80-11, Items 2(b) and 3, for the safety-related masonry walls not covered in our initial safety evaluation dated October 18, 1983. The results of our review are contained in the enclosed supplementary safety evaluation.

We have concluded that the safety-related masonry wall design of the remaining walls is adequate and, therefore, Items 2(b) and 3 of IE Bulletin 80-11 are now fully implemented for all safety-related walls at th( Fort St. Vrain Station.

If you have any question or comments, please contact Kenneth Heitner, our project manager for your facility, at (301) 492-7364.

Sincerely, l<

Herbert N. Berkow, Director Standardization and Special Projects Directorate Division of PWR Licensing-B

Enclosure:

As stated cc w/ enclosure:

See next page e.

Mr. R. F. Walker Public Service Company of Colorado Fort St. Vrain cc:

Mr. D. W. Warembourg, Manager Albert J. Hazle, Director Nuclear Engineering Division Radiation Control Division Public Service Company Department of Health *_

of Colorado 4210 East lith Avenue P. O. Box 840 Denver, Colorado 80220 Denver, Colorado 80201 Mr. David Alberstein,14/159A Mr. J. W. Gahm, Manager GA Technologies, Inc.

Nuclear Production Division Post Office Box 85608 Public Service Company of Colorado San Diego, California 92138 16805 Weld County Road 19-1/2 Platteville, Colorado 80651 Mr. H. L. Brey, Manager Nuclear Licensing and Fuel Division Mr. L. W. Singleton, Manager Public Service Company of Colorado Quality Assurance Division t

P. O. Box 840 Fort St. Vrain Nuclear Station Denver, Colorado 80201 16805 Weld County Road 19-1/2 Platteville, Colorado 80651 Senior Resident Inspector U.S. Nuclear Regulatory Commission P. 0. Box 640 Platteville, Colorado 80651 Kelley, Stansfield & 0'Donnell 4

Public Service Company Building Room 900 550 15th Street Denver, Colorado 80202 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission i

Office of Executive Director for Operations 611 Ryan Plaza Drive, Suite 1000 Arlington, Texas 76011 Chairman, Board of County Commissioners of Weld County, Colorado Greeley, Colorado 80631 Regional Representative Radiation Programs Environmental Protection Agency 1800 Lincoln Street Denver, Colorado 80203 e.

i l

1 i

.-