05000336/LER-1997-014, Forwards LER 97-014-00 Which Documents an Event That Occurred on 970415.Commitments Made within Ltr,Submitted

From kanterella
(Redirected from ML20141E206)
Jump to navigation Jump to search
Forwards LER 97-014-00 Which Documents an Event That Occurred on 970415.Commitments Made within Ltr,Submitted
ML20141E206
Person / Time
Site: Millstone 
Issue date: 05/13/1997
From: Price J
NORTHEAST NUCLEAR ENERGY CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
Shared Package
ML20141E211 List:
References
B16445, NUDOCS 9705200363
Download: ML20141E206 (2)


LER-1997-014, Forwards LER 97-014-00 Which Documents an Event That Occurred on 970415.Commitments Made within Ltr,Submitted
Event date:
Report date:
Reporting criterion: 10 CFR 50.73(a)(2)(v), Loss of Safety Function
3361997014R00 - NRC Website

text

-

- 4

^

, Northead Hoge Fmy Rd. (Houte % WataforW 06385 Nuclear Energy nii too, Noci,a, po.,r s,ation Northeast Nuclear Energy Company P.O. Box 128 Waterford. CT 06.385-0128 (860) 447-1791 Fax (860) 444-4277 The Northeast IJtilities System May 13, 1997 Docket No. 50-336 B16445 Re: 50.73(a)(2)(v)

U.S. Nuclear Regulatory Commission Document Control Desk I

- Washington, DC 20555 This letter forwards Licensee Event Report (LER) 97-014-00, documenting an event that occurred at Millstone Nuclear Power Station, Unit No. 2 on April 15,1997. This LER is being submitted pursuant iu 10 CFR 50.73(a)(2)(v).

The following are NNECO's commitments made within this letter.

B16445-01:

The required design flow and the effect that any deficient flow has on the HPSI pump seal coolers performance and mechanical seal integrity will be evaluated.

A seal cooler flow adequacy evaluation will be completed as part of the ongoing reanalysis of the RBCCW System.

Based on these results, RBCCW piping modifications and/or design document revisions will be implemented.

These activities will be completed prior to entry into Mode 4 from the current outage.

B16445-02:

A supplemental LER will be issued to provide the results of the investigation including the cause of the event and resultant corrective actions.

//

Very truly yours, NORTHEAST NUCLEAR ENERGY COMPANY 9705200363 970513 r

PDR ADOCK 05000336 J.A.Prc 0

PDR b Direct Millstone Unit No. 2 4-t=NuYi O hflfllf!,!!!,!!,!I i

U. S. Nuclecr R:gul: tory Commission

.B16445/Page 2

~ Attachment: LER 97-014-00 cc:

W. D. Travers, Director of Special Projects H. J. Miller, Region l Administrator D. P. Beaulieu, Senior Resident Inspector, Millstone Unit No. 2 D. G. Mcdonald, Jr., NRC Senior Project Manager, Millstone Unit No. 2 t

i h

l d

l l

I I

r u