. ~. ~ ~ - - -.. _.

.. ~. -.. _.,. _ -.. _..

BYRON NUCLEAR POWER STATION r

EFFLUENT AND WASTE DISPOSAL REPORT JANUARY through DECEMBER 1996 Supplemental Information

+

Batch Releasess a.

Liquid:

6.

Average stream flow during periods of release of effluent i

into 's flowing ' stream = 217.8 m'/sec., based on information from the National Weather Service or Army Corps of Engineers for the Rock River.

1 l

l 1

l' i

j j

1 N

4 9704250181 970417 F PDR ADOCK 05000454 i

R PDR(

~

. (p:\\radprot\\ addendum.wpf)

i l

BRP 6100-6T1 J

j Ravision 3 BYRON NUCLEAR POWER STATION i

UNIT 1 DOCKET NUMBER STN-50-354 RADIOACTIVE EFFLUENT RELEASE REPORT Januarv 1996 THROUGH December 1996 GASEOUS EFFLUENTS - SUEMATION OF ALL RELEASES B.

IODINE RELEASES **

1.

Total I-131/I-133 Activity Ci

<LLD 2.36E-4

<LLD

<LLD 2.

I-131/I-133 Release Rate uC1/sec 0.00 3.00E-5 0.00 0.00 C.

PARTICULATE (>8 day half-life) RELEASES **

j 1.

Gross Activity Ci

<LLD

<LLD 7.63E-5 1.49E-5 2.

Particulate Release Rate uci/sec 0.00 0.00 9.60E-6 1.87E-6 l

3.

Gross Alpha Activity for Quarter Ci

<LLD

<LLD 3.04E-6

<LLD D.

TRITIUM RELEASES **

1.

Total Release Activity Ci 1.35E+1 1.65E+1 1.97E+0 3.36E-1 2.

Tritium Release Rate uCi/sec 1.74E+0 2.10E+0 2.48E-1 4.23E-2 Iodine, particulate, and tritium are expressed as a total limit.

i l

i l

r (ptadprot\\ addendum.wp0

l BRP 6100-6T1 Revision 3 s.

BYRON NUCLEAR POWER STATION UNIT _2__ DOCKET NUMBER STN-50-4ii___

RADIOACTIVE EFFLUENT RELEASE. RETORT Januarv 1996 THROUGH December 1996 CASEOUS EFFLUENTS - SUMMATION OF ALL RELEASES B.

IODINE RELEASES **

1.

Total I-131/I-133 Activity Ci

<LLD 2.30E-4

<LLD

<LLD 2.

I-131/I-133 Release Rate uCL/sec 0.00 2.93E-5 0.00 0.00 C.

PARTICULATE (>8 day half-life) RELEASES **

1.

Gross Activity Ci

<LLD

<LLD 6.73E-6 7.67E-6 2.

Particulate Release Rate uCi/sec 0.00 0.00 8.47E-7 9.65E-7 3.

Gross Alpha Activity for Quarter Ci

<LLD

<LLD

<LLD

<LLD D.

TRITIUM RELEASES **

1.

Total Release Activity Ci 2.97E-1 1.620-1 4.43E+0 1.13E-1 2.

Tritium Release Rate uCi/sec 3.82E-2 2.06E-2 5.57E-1 1.42E-2

i l

-S-(p:\\cdprot\\ addendum.wp0

BRP 6100-6TA Revision 3 I

BYRON NUCLEAR POWER STATION

]

UNIT 1/2 DOCKET NUMBER STN-50-454/455 RADIOACTIVE EFFLUENT RELEASE REPORT Januarv 1996 THROUGH December 1996 SOLID RADIOACTIVE WASTE FOR BURIAL let OUARTER 1996 YEAR DISPOSITION OF HATERIAL VOLUME (DESCRIPTION, CLASS, MODE PER CURIES

  • TYPE, AND SOLIDIFYING OF SHIPMENT PER DATE AGENT)

TRANSPORT DESTINATION CUBIC M SHIPMENT Steam Generator Secondary Exclusive Oak Ridge 22.3 0.010 01/15/96 Sludge, Low Specific Activity, Use TN NOS 7 UN2912 strong-tight container, none 01/22/96 Steam Generator Secondary Exclusive Oak Ridge 16.7 0.008 Sludge, Low Specific Activity, Use TN NOS 7 UN2912 strong-tight container, none 03/25/96 Dewatered Bead Resin, Class A Exclusive Barnwell 5.72 4.17 Stable, HIC, none Use SC 1

4 j

44.8 4.19 QUARTERLY TOTALS - NUMBER OF SHIPMENTS:

3 CUBIC M CURIES calculated using measured ratios a (p:\\radpnnddendum.wp0

l l

BRP 6100-6T1 l,,

Revision 3 BYRON NUCLEAR POWER STATION UNIT 1/2 DOCKET NUMBER STN-50-454/455 RADIOACTIVE EFFLUENT RELEASE REPORT Januarv 1996 THROUGH December 1996 SOLID RADIOACTIVE WASTE FOR BURIAL 2nd OUARTEE 1996 YEA 3 DISPOSITION OF MATERIAL VOLUME (DESCRIPTION, CLASS, MODE PER CURIES

  • TYPE, AND SOLIDIFYING OF SHIPhENT PER DATE AGENT)

TRANSPORT DESTINATION CUBIC M SHIPMENT l

RTD Piping, Low Specific Exclusive Barnwell 67.5 1.87 04/23/96 Activity NOS 7 UN2912, Use SC strong-tight container, None 04/22/96 RTD Piping, Low Specific Exclusive Barnwell 67.5 1.99 Activity NOS 7 UN2912, Use SC strong-tight container, None 05/01/96 Dewatered Bead Resin, Class A Exclusive Barnwell 5.72 51.9 Stable, HIC, none Use SC 05/09/96 RTD Piping, Low Specific Exclasive Barnwell 67.5

.004 j

Activity NOS 7 UN2912, Use SC strong-tight container, None 05/22/96 Dewatered Bead Resin, Class A Exclusive Barnwell 5.72 19.0

)

Stable, HIC, none Use SC 06/03/96 Dewatered Dead Resin, Class A Exclusive Barnwell 5.72 141 Stable, HIC, none Use SC 1

219.5 215.8 QUARTERLY TOTALS - NUMBER OF SHIPMENTS:

6 CUBIC M CURIES

  • Calculated using measured ratios (p:\\radpmt\\ addendum.wpf)

BRP 6100-6T1 t

Revision 3 BYRON NUCLEAR POWER STATION UNIT 1/2 DOCKET NUMBER STN-50-454/455 RADIOACTIVE EFFLUENT RELEASE REPORT 1

Januarv 1996 THROUGH December 1996 EQLID RADIOACTIVE WASTE FOR BURIAL 3rd OUARTER 1996__

YEAR DISPOSITION OF MATERIAL VOLUME i

(DESCRIPTION, CLASS, MODE PER CURIES

  • TYPE, AND SOLIDIFYING OF SHIPMENT PER DATE AGENT)

TRANSPORT DESTINATION CUBIC M SHIPMENT Dewatered Bead Pesin, Class A Exclusive Barnwell 5.72 11.2 07/31/96 Stable, HIC, none Use SC 08/29/96 RTD Piping, Low Specific Exclusive Barnwell 72.5 12.80 j

Activity NOS 7 UN2912, Use SC strong-tight container, None 08/29/96 RTD Piping, Low Specific Exclusive Barnwell 72.5 12.90 Activity NOS 7 UN2912, Use SC strong-tight container, None 08/28/96 Dewatered Bead Resin, Class A Exclusive Barnwell 5.72 6.70 Stable, HIC, none Use SC 09/11/96 RTD Piping, Low Specific Exclusive Barnwell 77.0

.002 Activity NOS 7 UN2912, Use SC strong-tight container, None 233.5 43.6 QUARTERLY TOTALS - NUMBER OF SHIPMENTS:

5 CUBIC M CURIES

  • Calculated using measured ratios @:\\radprm%ddendum.uTO J

BRP 6100-6T1 Revision 3 BYRON NUCLEAR POWER STATION UNIT 1/2 DOCKET NUMBER STN-50-454/455 RADIOACTIVE EFFLUENT RELEASE REPORT Januarv 1996 THROUGH December 1996 SOLID RADIOACTIVE WASTE FOR BURIAL 4th OUARTER 1996 YEAR DISPOSITION OF MATERIAL VOLUME (DESCRIPTION, CLASS, MODE PER CURIES

  • TYPE, AND SOLIDIFYING OF

. SHIPMENT PER DATE AGENT)

TRANSPORT DESTINATION CUBIC M SHIPMENT 10/04/96 Steam Generator Secondary Exclusive Oak Ridge 72.5 2.19 Sludge Low Specific Activity Use TN NOS 7 UN2912 strong-tight container, none 10/11/96 Dewatered Bead Resin, Class A Exclusive Barnwell 5.72 9.90 Stable, HIC, none Use SC 10/2B/96 Dewatered Bead Resin, Class A Exclusive Barnwell 5.72 24.4 Stable, HIC, none Use SC 10/29/96 Dewatered Bead Resin, Class A Exclusive Barnwell 5.72 0.50 Stable, HIC, none Use SC 89.7 37.0 QUARTERLY TOTALS - NUMBER OF SHIPMENTS:

4 CUBIC M CURIES

  • Calculated using measured ratios l

1 i

i (p:\\radprot\\ addendum.wpf)

BRP 6100-6T1 e

Rsvision 3 ATTACHMENT A 8YRON NUCLEAR POWER STATION EFFLUENT AND WASTE DISPOSAL REPORT FOR JANUARY THROUGH DECEMBER, 1996 UNIT 1 AND 2 (DOCKET NUMBERS 50-454 AND 50-455)

LLD VALUES FOR GASEOUS RELEASES Isotopes LLD(C1/ml)

H-3 4.04E-17 Ar-41 2.29E-13 Co-58 5.51E-19 Co-60 3.89E-18 Zn-69m 2.67E-18 Kr-85 4.88E-11 Kr-85m 1.73E-12 Kr-87 3.76E-13 Kr-88 5.78E-13 Sr-89

3. 5 8,E-21 Sr-90 1.22E-21 Sn-113 5.41E-20 Te-123m 3.23E-19 I-131 5.'/0E-19 I-132 6.16E-19 I-133 5.99E-19 I-135 2.47E-19 Xo-131m 7.55E-12 Xe-133 4.88E-13 Xe-133m 1.60E-12 Xe-135 1.80E-13 Xe-135m 2.19E-13 Xe-138 4.99E-13 Cs-134 9.08E-12 Cs-137 1.10E-11 Ba/La-140 6.16F-11 (i :\\radprot\\ addendum wpf)

BRP 6100-6T1 l

Ravision 3 l

l l

ATTACHMENT A (cont.)

BYRON NUCLEAR POWER STATION I

EFFLUENT AND WASTE DISPOSAL REPORT FOR JANUARY THROUGH DECEMBER, 1996 1

UNIT 1 AND 2 (DOCKET NUMBERS 50-454 AND 50-455) l LLD VALUES FOR LIQUID RELEASES Isotopes LLD(Ci/ml) i H-3 1.63E-12 l

Ar-41 2.32E-13 Cr-51 2.21E-13 Mn-54 3.23E-14 Fe-55 5.40E-14 Fe-59 8.02E-14 Co-57 2.08E-14 Co-58 3.74E-14 Co-60 5.40E-14 I

Cu-64 3.04E-14 Zn-65 7.55E-14 Kr-85 4.07E-11 Kr-88 7.60E-14 Sr-89 2.13E-14 Sr-90 9.30E-15 Sr-92 2.82E-13 Nb-95 3.13E-14 Zr-95 5.68E-14 Mo-99 1.17E-13 Tc-99m 4.19E-14 Ag-110m 1.97E-13 Sn-113 2.37E-13 Sb-122 2.52E-13 Sb-124 2.95E-14 Sb-125 7.44E-14 (p:\\radpmt\\ addendum.wp0

.. = _ _

BRP 6100-6T1 Revision 3 ATTACHMENT A (cont.)

BYRON NUCLEAR POWER STATION

' EFFLUENT AND WASTE DISPOSAL REPORT FOR JANUARY THROUGH DECEMBER, 1996 UNIT 1 AND 2 (DOCKET NUMBERS 50-454 AND 50-455)

LLD VALUES FOR LIQUID RELEASES Isotopes LLD(Ci/ml)

Sb-126 2.03E-13 Te-121m 8.82E-14 Te-123m 2.28E-14 Te-125m 5.91E-12 Te-132 1.60E-13 Xe-125m 5.91E-12 Xe-131m 9.95E-13 Xe-133 2.44E-13 Xe-133m 2.11E-13 Xe-135 2.37E-14 Cs-134 2.89E-14 Cs-136 3.16E-14 Cs-137 3.72E-14 I-131 3.37E-13 I-132 2.94E-14 I-133 3.04E-14 I-134 1

3.62E-14 I-135 1.17E-13 Ba/La-140 1.97E-13 Ce-141 3.81E-14 Ce-144 1.69E-13 Pr-144 1.40E-11 Hf-181 2.30E-13 (Final) (p:\\radend\\ addendum.wpf)

BYRON STATION UNIT ONE ACTUAL 1996 MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PERIOD OF RELEASE - 01/01/96 TO 12/31/96 CALCULATED 04/09/97 INFANT RECEPTOR IST 2ND 3RD 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC GAMMA AIR 2.31E-05 5.43E-05 2.99E-06 2.28E-06 8.27E-05 (MRAD)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

BETA AIR 9.35E-05 2.20E-04 1.16E-05 8.96E-06 3.34E-04 (MRAD)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

TOT. BODY 1.62E-05 3.82E-05 2.11E-06 1.61E-06 5.81E-05 (MREM)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

SKIN 4.59E-05 1.07E-04 5.80E-06 4.44E-06 1.64E-04 (MREM)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

ORGAN 5.91E-03 7.45E-03 8.85E-04 1.64E-04 1.44E-02 (MREM)

(NE

)

(NE

)

(NE

)

(hE

)

(NE

)

LIVER THYROID LUNG LUNG THYROID THYROID KIDNEY LUNG GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1996 COMPLIANCE STATUS - 10CFR 50 APP. I INFANT RECEPTOR


 % OF APP I.

QTRLY 1ST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I GAMMA AIR (MRAD) 5.0 0.00 0.00 0.00 0.00 10.0 0.00 BETA AIR (MRAD) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 TOT. BODY (MREM) 2.5 0.00 0.00 0.00 0.00 5.0 0.00 SKIN (MREM) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 ORGAN (MREM) 7.5 0.08 0.10 0.01 0.00 15.0 0.10 LIVER THYROID LUNG LUNG THYROID THYROID KIDNEY LUNG GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

t BYRON' STATION UNIT ONE l

i ACTUAL 1996 L

. MAXIMUM DOSES (MREM) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/96 TO 12/31/96-CALCULATED 02/20/97 L

INFANT RECEPTOR IST

.2ND 3RD 4TH.

DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 2.64E-04 2.77E-04 1.31E-04 6.05E 1.28E-03

-BODY INTERNAL 2.65E-04 3.11E-04 1.87E-04 6.05E-04 1.37E-03 ORGAN-LIVER LIVER LIVER GI_LLI LIVER-THIS.IS A REPORT FOR THE CALENDAR YEAR 1996 y

COMPLIANCE STATUS - 10 CFR 50 APP. I l


 % OF APP I.

l QTRLY 1ST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF-OBJ

'JAN-MAR-APR-JUN JUL-SEP

'OCT-DEC OBJ APP. I i

TOTAL BODY.(MREM) 1.5 0.02 0.02 0.01 0.04 3. 40 0.04 CRIT. ORGAN (MREM) 5.0 0.01 0.01 0.00 0.01 10.0 0.01 r

LIVER LIVER LIVER GI_LLI LIVER RESULTS BASED UPON:

ODCM ANNEY REVISION 1.3 MARCH.1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 4

7 k

k I

(~

e f

n.-n

--y,

BYRON STATION UNIT ONE 1996 ANNUAL REPORT i

PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/96 TO 12/31/96 CALCULATED 02/20/97 INFANT RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 2.64E-04 2.77E-04 1.31E-04 6.05E-04 1.28E-03 BODY a

INTERNAL 2.65E-04 3.11E-04 1.87E-04 6.05E-04 1.37E-03 ORGAN LIVER LIVER LIVER GI_LLI LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1996 COMPLIANCE STATUS - 40 CFR 141 1

TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 MREM 0.032 BODY INTERNAL 4.0 MREM 0.034 1

ORGAN LIVER i

o THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE j

COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL.

THESE TECHNIQUES DIFFER

{

FROM THOSE DESCRIBED IN 40 CFR 141.

2 RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

r.

BYRON STATION UNIT ONE ACTUAL 1996 MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PERIOD'OF. RELEASE - 01/01/96 TO 12/31/96 CALCULATED 04/09/97 I

CHILD RECEPTOR IST 2ND 3RD 4TH 1

TYPE QUARTER QUARTER-QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC l

GAMMA AIR' 2.31E-05 5.43E-05 2.99E-06 2.28E-06 8.27E-05 (MRAD)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

i

BETA AIR 9.35E-05 2.20E-04 1.16E-05 P,.96E-06 3.34E-04 (MRAD)-

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

TOT. BODY 1.62E-05 3.82E-05 2.11E-06 1.61E-06 5.81E-05 (MREM)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

l

_' SKIN 4.59E-05 1.07E-04 5.80E-06 4.44E-06 1.64E-04 (MREM)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

ORGAN 4.16E-03 8.82E-03 3.45E-03 3.29E-04 1.52E-02

?

(MREM)

(NE

)

(S

-)

(SSE )

(SE

)

(S

)

LIVER THYROID GI LLI GI LLI THYROID i

~

~

THYROID KIDNEY i

LUNG I

GI LLI THIS IS A REPORT F6R THE CAL"NDAR YEAR 1996

)

i p

i COMPLIANCE STATUS - 10CFR 50 APP. I CHILD RECEPTOR


 % OF APP I.

4 QTRLY iST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I GAMMA AIR (MRAD) 5.0 0.00 0.00 0.00 0.00 10.0 0.00

'BerA AIR - (MRAD) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 TOT. BODY (MREM) 2.5 0.00 0.00 0.00 0.00 5.0 0.00 SKIN (MREM) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 i

ORGAN (MREM) 7.5 0.06 0.12 0.05 0.00 15.0 0.10 LIVER THYROID GI_LLI GI_LLI THYROID THYROID KIDNEY LUNG GI_LLI f

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 i

ODCM DATABASE VERSION 1.1 January 1995 1

.. ~

BYRON STATION UNIT ONE It ACTUAL 1996

. MAXIMUM DOSES (MREM) RESULTING FROM AQUATIC EFFLUENTS PERIOD OF RELEASE.- 01/01/96 TO 12/31/96 CALCULATED 02/20/97 CHILD RECEPTOR

.1ST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC J

TOTAL-6.59E-04 1.27E-03 3.32E-03 7.92E-04 6.04E-03

- BODY.

INTERNAL

.1.91E-03 3.39E-03 1.55E-02 9.29E-04 2.18E-02 ORGAN LIVER LIVER LIVER LIVER LIVER j

THIS IS A REPORT FOR THE CALENDAR YEAR 1996

. COMPLIANCE STATUS - 10 CFR 50 APP. I


 % OF APP I.

l QTRLY 1ST QTR 2ND QTR 3RD QTR " 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (MREM) 1.5 0.04 0.08 0.22 0.05 3.0 0.20

' CRIT. ORGAN (MREM) 5.0 0.04 0.07 0.31 0.02-10.0 0.22 LIVER LIVER LIVER LIVER LIVER i

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January l1995 l

1

..-. -- -.-.~ - -

l

}

8 BYRON STATION UNIT ONE i

1996 ANNUAL REPORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/96 TO 12/31/96 CALCULATED 02/20/97 CHILD RECEPTOR 1ST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 2.67E-04 2.81E-04 1.36E-04 6.08E-04 1.29E-03 BODY.

i INTERNAL-2.65E-04 3.10E-04 1.76E-04 6.12E-04 1.36E-03 j_' ORGAN LIVER LIVER LIVER GI_LLI LIVER i

THIS IS A REPORT FOR THE CALENDAR YEAR 1996 i

COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT'

% OF LIMIT j

TOTAL 4.0 MREM 0.032 BODY INTERNAL 4.0 MREM 0.034

. ORGAN LIVER 0

THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL.

THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 H

ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 i

I 1

i I

i BYRON STATION UNIT ONE ACTUAL 1996

.l MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES 4

-PERIOD OF RELEASE - 01/01/96 TO 12/31/96 CALCULATED 04/09/97 TEENAGER RECEPTOR 1ST 2ND 3RD 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC GAMMA AIR 2.31E-05 5.43E-05 2.99E-06 2.28E-06 8.27E-05 (MRAD)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

BETA AIR 9.35E-05 2.20E-04 1.16E 8.96E-06 3.34E-04 (MRAD)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

? TOT. BODY 1.62E-05 3.82E-05 2.11E-06 1.61E-06 5.81E (MREM)~

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

SKIN 4.59E~05 1.07E-04 5.80E-06 4.44E-06 1.64E-04

-(MREM)

(SSE )-

(SSE )

(SSE )

(SSE )

(SSE )

ORGAN 2.72E-03 6.29E-03 2.26E-03 2.31E-04 1.10E-02 i

(MREM)-

(NE

)

(S

)

(SSE )

(SE

)

(S

)

]

LIVER THYROID GI_LLI GI_LLI THYROID THYROID KIDNEY LUNG GI_LLI I

THIS IS A REPORT FOR THE CALENDAR YEAR 1996 l

COMPLIANCE STATUS - 10CFR 50 APP. I TEENAGER RECEPTOR


 % OF APP I. ------------

QTRLY IST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF l

OBJ JAN-MAR APR-JUN JUL-SEP

~OCT-DEC OBJ'

' APP. I i

GAMMA AIR'(MRAD) 5.0 0.00 0.00 0.00 0.00 10.0 0.00 BETA AIR (MRAD) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 TOT. BODY (MREM) 2.5 0.00 0.00 0.00 0.00 5.0 0.00 SKIN-(MREM) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 ORGAN (MREM) 7.5 0.04 0.08 0.03 0.00 15.0 0.07 LIVER THYROID GI_LLI GI_LLI THYROID THYROID KIDNEY LUNG GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

L.

BYRON STATION UNIT ONE ACTUAL 1996

< MAXIMUM DOSES (MREM) RESULTING FROM AQUATIC EFFLUENTS i

PERIOD OF RELEASE - 01/01/96 TO 12/31/96 CALCULATED 02/20/97 TEENAGER RECEPTOR 1ST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL i '

JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL-1.03E-03 1.62E-03 8.11E-03 5.64E-04 1.13E-02 BODY-i INTERNAL 2.03E-03 7.93E-03 1.79E-02 8.86E-04 2.42E-02 ORGAN LIVER GI_LLI LIVER GI_LLI LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1996 COMPLIANCE STATUS - 10 CFR-50 APP. I


 % OF APP I.

QTRLY 1ST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN

-JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (MREM) 1.5 0.07 0.11 0.54 0.04 3.0 0.38 CRIT. ORGAN (MREM) 5.0 0.04 0.16 0.36 0.02 10.0 0.24 LIVER GI_LLI LIVER GI_LLI.

LIVER RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

4 j

BYRON STATION UNIT ONE l-1996 ANNUAL REPORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/96 TO 12/31/96 CALCULATED 02/20/97 TEENAGER RECEPTOR IST 2ND 3RD 4TH i

DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 1.40E-04 1.41E-04 7.6SE-05 3.17E-04 6.75E-04 BODY INTERNAL 1.41E-04 1.92E-04 9.10E-05 3.26E-04 7.38E-04 ORGAN GI_LLI GI_LLI LIVER GI_LLI GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1996 COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL.

4.0 MREM 0.017 BODY

-INTERNAL 4.0 MREM 0.018 ORGAN GI_LLI a

THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DCSE CALCULATION MANUAL.

THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM~ SOFTWARE VERSION 1.1 January 1995 1

ODCM DATABASE VERSION 1.1 January 1995 i

1 J

l 1.

_.. -. _.. _. _ _ ~. _.. -.. - _. - _. _.. _. _..

-i BYRON STATION UNIT TWO ACTUAL 1996L MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES I

PERIOD OF RELEASE - 01/01/96 TO 12/31/96 1 CALCULATED 02/25/97

[

INFANT RECEPTOR e-1 1ST 2ND-3RD 4TH i

TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL l

JAN-MAR APR-JUN JUL-SEP OCT-DEC 3

{

GAMMA AIR 6.11E-06' 9.79E-06' 2.95E-06 1.98E-06 2.08E-05

~

-(MRAD)

(SSE )

(SSE )-

(SSE )

(SSE )

(SSE )

{

DETA AIR 2.20E-05 3.89E-05 1.11E-05 7.00E-06 7.90E-05

-(MRAD)

(SSE-)

(SSE )

(SSE )

(SSE )

(SSE )-

TOT. BODY 4.35E-06 6.92E-06

-2.08E-06 1.41E-06 1.48E-05.

j-

-(MREM)

(SSE.)

.(SSE )

(SSE )

(SSE )

'(SSE )

j SKIN.

1.22E-05 2.02E-05 5.65E-06 3.69E-06 4.17E-05 1

'(MREM)

(SSE )

(SSE )

(SSE )

(SSE )-

(SSE )

ORGAN-1.30E-04 1.51E-03 1.96E-03 5.79E-05 3.65E l (MREM)

(NE -' )

(NE

)

(NE

)

(NE

)

(NE

)

l LIVER THYROID

' LUNG LUNG

_ THYROID l

THYROID KIDNEY g_

j LUNG

?

GI LLI THIS IS.A REPORT FOR THE CALENDAR YEAR 1996 i

i d

COMPLIANCE STATUS - 10CFR 50 APP. I I

INFANT RECEPTOR

% OF APP I.

QTRLY 1ST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

~% OF OBJ' JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I GAMMA AIR (MRAD) 5.0 0.00 0.00 0.00 0.00 10.0 0.00 BETA AIR- (MRAD):

10.0 0.00 0.00 0.00-o0.00 20.0 0.00 TOT. BODY (MREM) 2.5-0.00 0.00 0.00 0.00-5.0 0.00

-SKIN.(MREM) 7.5 0.00~

0.00 0.00 0.00 15.0 0.00-

. ORGAN-(MREM)-

7.5 0.00 0.02 0.03 0.00 15.0 0.02 LIVER THYROID LUNG LUNG THYROID THYROID KIDNEY LUNG GI_LLI q

RESULTS BASED UPON:'

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

. - _. = _ _... _.. _.

A 7.,

o 1

BYRON STATION UNIT TWO I

l ACTUAL 1996

~

. MAXIMUM DOSES (MREM) RESULTING FROM AQUATIC EFFLUENTS i-PERIOD OF RELEASE - 01/01/96 TO 12/31/96 CALCULATED 02/20/97 i

INFANT RECEPTOR j

1ST 2ND 3RD 4TH I

i DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL i

JAN-MAR APR-JUU JUL-3EP OCT-DEC t

l TOTAL 2.64E-04 2.77E-04

1. 31E--04 6.05E-04 1.28E-03 l

}

BODY.

t-

-INTERNAL 2.65E-04 3.11E-04 1.87E-04 6.05E-04 1.37E-03 ORGAN j-LIVER.

LIVER LIVER GI LLI LT.VER I

THIS IS A REPORT FOR THE CALENDAR' YEAR'1996 i

COMPLIANCE STATUS - 10 CFR 50 APP. I j'


 % OF APF I.

?

QTRLY iST QTR 2ND QTR 3RD QTR 4TI QTR YRLY

%. 0F OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I i

TOTAL BODY (MREM) 1.5 0.02 0.02 0,01 0.04 3.0' O.04 CRIT.. ORGAN (MREM) 5.0 0.01

-0.01 0.00 0.01 10.0 0.01

]

LIVER LIVER LIVER GI LLI LIVER

^

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARF. VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 l

1 1

)

i

1 3

BYROF STATION UNIT TWO 1996 ANNUAL REPORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE - 01/01/96 TO 12/31/96 CALCULATED 02/20/97 INFANT RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER' QUARTER-QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL-2.64E-04 2.77E-04 1.31E-04 6.05E-04 1.28E-03 BODY INTERNAL 2.65E-04 3.11E-04 1.87E-04 6.05E-04 1.37E-03 ORGAN LIVER LIVER LIVER GI_LLI LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1996 COMPLIANCE STATUS - 40 CFR 141 TYPE ANNUAL LIMIT

% OF LIMIT TOTAL 4.0 MREM-0.032 BODY INTERNAL 4.0 MREM 0.034 ORGAN LIVER 0

THIS CALCULATION OF DOSE IS-BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CALCULATION MANUAL.

THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM' DATABASE VERSTON 1.1 January 1995 1

  • -)

l BYRON STATION UNIT TWO i

j' ACTUAL 1996 MAXIMUM DOSES RESULTING FROM AIRBORNE TELEASES j

PERIOD OF RELEASE - 01/01/96 TO 12/31/96 CALUULATED 02/25/97 l

CHILD RECEPTOR j

i 4

1ST 2ND 3RD 4TH l

TYPE

. QUARTER-QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP

~OCT-DEC.

i l

l GAMMA AIR 6.11E-06 9.79E-06 2.95E-06 1.98E-06 2.08E-05 t

(MRAD)

(SSE )

(SSE')

(SSE )

(SSE )

(SSE )

': BETA AIR 2.20E-05 3.89E-05 1.11E-05 7.00E-06 7.90E-05 i

(MRAD)-

(SSE )

(SSE-)

(SSE )

(SSE )

(SSE )

TOT.. BODY' 4.35E 6.92E-06 2.08E-06 1.41E-06 1.48E-05 i

-(MREM)

'(SSE )

(SSE )

(SSE )

.(SSE )

(SSE )

i SKIN 1.22E-05 2.02E-05 5.65E-06 3.69E-06 4.17E-05 L

(MREM)

, 9.18E-05' 1.04E-03 7.68E-03 6.05E-05 8.74E-03 (SSE.)

(SSE )

(SSE )

(SSE )

(SSE )

l' ORGAN i

(MREM)

(NE

)

(NE

)

(SSE )

(S

)-

(SSE )

LIVER THYROID GI LLI GI LLI THYROID l

~

~

j THYROID KIDNEY j

LWG

-GI_LLI l

THIS IS A REPORT FOR THE CALENDAR YEAR 1996 P

COMPLIANCE STATUS - 10CFR 50 APP. I i

i CHILD RECEPTOR

.I

]


 % OF APP I. ------------

QTRLY 1ST QTR 2ND QTR

-3RD QTR

'4TH QTR YRLY

% OF OBJ-JAN-MAR APR-JUN

.JUL-SEP OCT-DEC OBJ APP. I GAMMA AIR-(MRAD)

. 5.0 0.00 0.00 0.00 0.00 10.0 0.00 i

BETA AIR (MRAD) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 TOT. BODY (MREM) 2.5 0.00 0.00 0.00 0.00 5.0 0.00 SKIN (MREM) 7.5 0.00 0.00-0.00 0.00 15.0 0.00 ORGAN.(MREM) 7.5 0.00 0.01 0.10 0.00 15.0 0.06 LIVER THYROID GI_LLI GI_LLI THYROID THYROID KIDNEY LUNG GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

, _ ~

~

3 BYRON STATION UNIT TWO 1

ACTUAL 1996

. MAXIMUM DOSES (MREM) RESULTING FROM. AQUATIC EFFLUENTS PERIOD OF RELEASE - 01/01/96 TO 12/31/96 CALCULATED 02/20/97

' CHILD RECEPTOR 1ST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER

-QUARTER QUARTER ANNUAL l-JAN-MAR APR-JUN JUL-SEP OCT-DEC-TOTAL 6.59E 1.27E-03 3.32E-03 7.92E-04 6.04E-03 BODY

^

INTERNALc 1.91E-03 3.39E-03 1.55E-02 9.29E-04

'2.18E-02

-ORGAN-LIVER LIVER LIVER LIVER LIVER i

THIS IS A REPORT FOR THE CALENDAR YEAR 1996 COMPLIANCE STATUS - 10 CFR 50 APP. I


 % OF APP I.

QTRLY 1ST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (MREM) 1.5 0.04 0.08 0.22 0.05 3.0-0.20 CRIT. ORGAN (MREM) 5.0 0.04 0.07 0.31 0.02 10.0-0.22 j

LIVER LIVER LIVER LIVER LIVER 1

RESULTS. BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH'1996

)

ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 l

- =...... -. - ~ _ _. __-. ~..

BYRON STATION UNIT TWO 2

1996 ANNUAL REPORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • i PERIOD OF RELEASE - 01/01/96 TO 12/31/96 CALCULATED 02/20/97 CHILD RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC i

i TOTAL 2.67E-04 2.81E-04 1.36E-04 6.08E-04 1.29E-03 BODY INTERNAL 2.65E-04 3.10E-04 1.76E-04 6.12E-04 1.36E-03 i

ORGAN LIVER LIVER LIVER GI LLI LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1996 COMPLIANCE STATUS - 40 CFR 141 1

TYPE ANNUAL. LIMIT

% OF LIMIT TOTAL 4.0 MREM 0.032-BODY-t

. INTERNAL

.4.0 MREM 0.034 ORGAN LIVER THIS CALCULATION 01' DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH HDISON OFFSITE DOSE CALCULATION MANUAL.

THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3. MARCH 1996.

ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 i

5 I

i 4

4 l

i

BYRON STATION UNIT TWO ACTUAL 1996 MAXIMUM DOSES RESULTING FROM AIRBORNE RELEASES PERIOD OF RELEASE - 01/01/96 TO 12/31/96 CALCULATED 02/25/97 TEENAGER RECEPTOR IST 2ND 3RD 4TH TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC 1

GAMMA AIR 6.11E-06 9.79E-06 2.95E-06 1.98E-06 2.08E-05 (MRAD)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

d BETA AIR 2.20E-05 3.89E-05 1.11E-05 7.00E-06 7.90E-05 (MRAD)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

TOT. BODY 4.35E-06 6.92E-06 2.08E-06 1.41E-06 1.48E-05 (MREM)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

SKIN 1.22E-05 2.02E-05 5.65E-06 3.69E-06 4.17E-05 (MREM)

(SSE )

(SSE )

(SSE )

(SSE )

(SSE )

ORGAN 5.99E-05 6.40E-04 5.01E-03 4.85E-05 5.71E-03 (MREM)

(NE

)

(SSE )

(SSE )

(S

)

(SSE )'

LIVER THYROID GI_LLI GI_LLI THYROID THYROID KIDNEY LUNG i

GI_LLI THIS IS A REPORT FOR THE CALENDAR YEAR 1996 l

COMPLIANCE STATUS - 10CFR 50 APP. I TEENAGER RECEPTOR a


 % OF APP I.

QTRLY iST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I GAMMA AIR (MRAD) 5.0 0.00 0.00 0.00 0.00 10.0 0.00 BETA AIR (MRAD) 10.0 0.00 0.00 0.00 0.00 20.0 0.00 TOT. BODY (MREM) 2.5 0.00 0.00 0.00 0.00 5.0 0.00 SKIN (MREM) 7.5 0.00 0.00 0.00 0.00 15.0 0.00 i

ORGAN (MREM) 7.5 0.00 0.01 0.07 0.00 15.0 0.04 LIVER THYROID GI_LLI GI_LLI THYROID THYROID KIDNEY LUNG r

GI_LLI RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

,= #

4 BYRON STATION UNIT TWO ACTUAL 1996 MAXIMUM DOSES (MREM) RESULTING FROM AQUATIC EFFLUENTS

+

PERIOD OF RELEASE - 01/01/96 TO 12/31/96 CALCULATED 02/20/97 TEENAGER RECEPTOR 1ST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC TOTAL 1.03E-03 1.62E-03 8.11E-03 5.64E-04 1.13E-02 BODY 5

INTERNAL 2.03E-03 7.9JE-03 1.79E-02 8.86E-04 2.42E-02 ORGAN LIVER GI_LLI LIVER GI_LLI LIVER THIS IS A REPORT FOR THE CALENDAR YEAR 1996 i

I COMPLIANCE STATUS - 10 CFR 50 APP. I i


 % OF APP I.

QTRLY 1ST QTR 2ND QTR 3RD QTR 4TH QTR YRLY

% OF OBJ JAN-MAR APR-JUN JUL-SEP OCT-DEC OBJ APP. I TOTAL BODY (MREM) 1.5 0.07 0.11 0.54 0.04 3.0 0.38 CRIT. ORGAN (MREM) 5.0 0.04 0.16 0.36 0.02 10.0 0.24 LIVER GI_LLI LIVER GI_LLI LIVER RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996 ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995

. ~.. _

-... -. - _. ~_

a',m BYRON STATION UNIT Th.

1996 ANNUAL REPORT PROJECTED DOSE AT NEAREST COMMUNITY WATER SYSTEM

  • PERIOD OF RELEASE

- 01/01/96 TO 12/31/96 CALCULATED 02/20/97 TEENAGER RECEPTOR IST 2ND 3RD 4TH DOSE TYPE QUARTER QUARTER QUARTER QUARTER ANNUAL JAN-MAR APR-JUN JUL-SEP OCT-DEC-TOTAL 1.40E-04 1.41E-04 7.68E-05 3.17E-04 6.75E-04 BODY l

' INTERNAL-1.41E-04 1.92E-04 3.10E-05 3.26E-04 7.38E-04 ORGAN GI_LLI GI_LLI LIVER GI_LLI GI_LLI l

THIS IS A REPORT FOR THE CALENDAR YEAR 1996 COMPLIANCE STATUS - 40 CFR 141

)

TYPE ANNUAL LIMIT

% OF LIMIT l

TOTAL 4.0 MREM 0.017 BODY INTERNAL 4.0 MREM 0.018 ORGAN GI_LLI o

THIS CALCULATION OF DOSE IS BASED ON TECHNIQUES DESCRIBED IN THE COMMONWEALTH EDISON OFFSITE DOSE CAICULATION MANUAL.

THESE TECHNIQUES DIFFER FROM THOSE DESCRIBED IN 40 CFR 141.

RESULTS BASED UPON:

ODCM ANNEX REVISION 1.3 MARCH 1996.

ODCM SOFTWARE VERSION 1.1 January 1995 ODCM DATABASE VERSION 1.1 January 1995 l-i i

I i

- -. _.