| | | Reporting criterion |
|---|
| 05000361/LER-1985-001, :on 850103,during Routine Fire Watches in Electrical Tunnel,Security Officers Did Not Respond Properly to Allow Entry.Caused by Failure of Personnel to Implement Revised Access Routing of Firewatch |
- on 850103,during Routine Fire Watches in Electrical Tunnel,Security Officers Did Not Respond Properly to Allow Entry.Caused by Failure of Personnel to Implement Revised Access Routing of Firewatch
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000362/LER-1985-001-02, :on 850127,RCS Water Inventory Balance Indicated 2.97 Gpm Leakage Rate,Exceeding 1.0 Gpm Limit.On 850128,containment Purge Isolation Sys Train a Actuated from Airborne Iodine Resulting from Leak |
- on 850127,RCS Water Inventory Balance Indicated 2.97 Gpm Leakage Rate,Exceeding 1.0 Gpm Limit.On 850128,containment Purge Isolation Sys Train a Actuated from Airborne Iodine Resulting from Leak
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) 10 CFR 50.73(a)(2)(6) |
| 05000362/LER-1985-002-02, :on 850220,five Snubbers on HPSI Sys Found Inoperable.Caused by Hydraulic Transient & Environ Degradation.Deficient Snubbers Replaced & Engineering Evaluation Performed |
- on 850220,five Snubbers on HPSI Sys Found Inoperable.Caused by Hydraulic Transient & Environ Degradation.Deficient Snubbers Replaced & Engineering Evaluation Performed
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(1) |
| 05000361/LER-1985-002, :on 850104,toxic Gas Isolation Sys Train a Actuation Occurred.Caused by Butane Channel Flame Out. Const Workers Instructed to Use Caution When Handling Matl |
- on 850104,toxic Gas Isolation Sys Train a Actuation Occurred.Caused by Butane Channel Flame Out. Const Workers Instructed to Use Caution When Handling Matl
| 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2) |
| 05000362/LER-1985-003-02, :on 850312,water Found in Resistance Temp Detector 3TE-0112-1.Caused by Small Leak in Thermowell. Detector Removed from Thermowell & Installed in Spare Thermowell.Thermowell Plugged & Seal Welded |
- on 850312,water Found in Resistance Temp Detector 3TE-0112-1.Caused by Small Leak in Thermowell. Detector Removed from Thermowell & Installed in Spare Thermowell.Thermowell Plugged & Seal Welded
| |
| 05000361/LER-1985-004, :on 850101,discovered Weekly Purge Samples Not Taken for Containment Purge Initiated on 841224.Caused by Personnel Error.Chemistry Foremen & Technicians Counseled |
- on 850101,discovered Weekly Purge Samples Not Taken for Containment Purge Initiated on 841224.Caused by Personnel Error.Chemistry Foremen & Technicians Counseled
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(1) |
| 05000362/LER-1985-004-01, :on 850130,analysis of RCS Sample Indicated RCS Specific Activity Exceeded 1.0 Uci/G Dose Equivalent I-131.Caused by Personnel Error.Appropriate Disciplinary Action Taken |
- on 850130,analysis of RCS Sample Indicated RCS Specific Activity Exceeded 1.0 Uci/G Dose Equivalent I-131.Caused by Personnel Error.Appropriate Disciplinary Action Taken
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) |
| 05000362/LER-1985-005-01, :on 850131 & 0201,Train B Containment Purge Isolation Sys Spuriously Actuated as Result of Instrument Intermittent Failure on Containment Area Radiation Monitor. Caused by Failure of Keylock Function Switch |
- on 850131 & 0201,Train B Containment Purge Isolation Sys Spuriously Actuated as Result of Instrument Intermittent Failure on Containment Area Radiation Monitor. Caused by Failure of Keylock Function Switch
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000361/LER-1985-005, Forwards LER 85-005-00 Re Control Room Isolation Actuation. Events Involve Components Common to Units 2 & 3.Single Rept Submitted in Accordance w/NUREG-1022 | Forwards LER 85-005-00 Re Control Room Isolation Actuation. Events Involve Components Common to Units 2 & 3.Single Rept Submitted in Accordance w/NUREG-1022 | 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000362/LER-1985-006-02, :on 850313,safety Injection Sys Automatically Actuated at RCS Pressure of 330 Psia.Caused by Unexpected Change in Position of Steam Bypass Valve.Design Change to Provide Demand/Actual Position Implemented |
- on 850313,safety Injection Sys Automatically Actuated at RCS Pressure of 330 Psia.Caused by Unexpected Change in Position of Steam Bypass Valve.Design Change to Provide Demand/Actual Position Implemented
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2) |
| 05000361/LER-1985-006-01, :on 850113,toxic Gas Isolation Sys Train a Actuated.Caused by Hydrocarbon Analyzer Flameout,Which Caused Instrument Failure Actuation Signal.Dirty Filters Replaced & Train a Tested & Restored |
- on 850113,toxic Gas Isolation Sys Train a Actuated.Caused by Hydrocarbon Analyzer Flameout,Which Caused Instrument Failure Actuation Signal.Dirty Filters Replaced & Train a Tested & Restored
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2) |
| 05000362/LER-1985-007-02, :on 850317,safety Injection Tank Valves Pressure Tested in Closed Position W/Rcs at 351 F.Caused by Personnel Error.Briefings Will Emphasize Necessity of Monitoring & Controlling RCS Temp |
- on 850317,safety Injection Tank Valves Pressure Tested in Closed Position W/Rcs at 351 F.Caused by Personnel Error.Briefings Will Emphasize Necessity of Monitoring & Controlling RCS Temp
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000361/LER-1985-007, :on 850103,containment Purge Isolation Sys Train B Actuated When Containment Area Radiation Monitor 2RT-7857 Cabinet Opened for Surveillance.Sign Will Be Placed on Door Cautioning Personnel |
- on 850103,containment Purge Isolation Sys Train B Actuated When Containment Area Radiation Monitor 2RT-7857 Cabinet Opened for Surveillance.Sign Will Be Placed on Door Cautioning Personnel
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000206/LER-1985-008-02, :on 850604,block Valve CV-530 to PORV CV-546 Failed to Indicate Closure During Testing.Containment Entry Confirmed CV-530 Partially Open.Caused by Actuator Diaphragm Leak.Diaphragm Replaced |
- on 850604,block Valve CV-530 to PORV CV-546 Failed to Indicate Closure During Testing.Containment Entry Confirmed CV-530 Partially Open.Caused by Actuator Diaphragm Leak.Diaphragm Replaced
| 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) 10 CFR 50.73(a)(2)(6) |
| 05000362/LER-1985-008-01, :on 850319,reactor Tripped Due to High Steam Generator Level When Main Feed Regulating Valve FV-1111 Failed 80% Open.Caused by Corrosive Capscrew Which Allowed Detachment of Feedback Mechanism from Valve |
- on 850319,reactor Tripped Due to High Steam Generator Level When Main Feed Regulating Valve FV-1111 Failed 80% Open.Caused by Corrosive Capscrew Which Allowed Detachment of Feedback Mechanism from Valve
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000206/LER-1985-009-02, :on 850301,vent Noble Gas Activity Monitor Setpoint Not Reset During Planned Release.Caused by Personnel Error.Permit Format Will Be Reorganized to Direct Operator to Verify Setpoint Correct |
- on 850301,vent Noble Gas Activity Monitor Setpoint Not Reset During Planned Release.Caused by Personnel Error.Permit Format Will Be Reorganized to Direct Operator to Verify Setpoint Correct
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(1) |
| 05000362/LER-1985-009-01, :on 850326,containment Emergency Fan Cooler 3E-401 Indicated Low Flow 300 Gpm Below 2,000 Gpm Tech Specs Limit.Caused by Manual Outlet Isolation Valve Not Set to Spec.Valve Set to Spec & Flow Level Restored |
- on 850326,containment Emergency Fan Cooler 3E-401 Indicated Low Flow 300 Gpm Below 2,000 Gpm Tech Specs Limit.Caused by Manual Outlet Isolation Valve Not Set to Spec.Valve Set to Spec & Flow Level Restored
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) |
| 05000361/LER-1985-009, :on 850117,containment Purge Isolation Sys Train a Spuriously Actuated.Caused by Electrical Noise Spikes on Containment Area Radiation Monitor 2RT-7856.Study of Plant Ground Sys Being Performed |
- on 850117,containment Purge Isolation Sys Train a Spuriously Actuated.Caused by Electrical Noise Spikes on Containment Area Radiation Monitor 2RT-7856.Study of Plant Ground Sys Being Performed
| 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2) |
| 05000206/LER-1985-010-02, :on 850508,past Failure to Make Continuous 4 H Flow Estimates on Effluent Releases Discovered. Procedures Revised to Require Estimates of Any Flow Through Stack If Fan Flow Indicator R-1254 Inoperable |
- on 850508,past Failure to Make Continuous 4 H Flow Estimates on Effluent Releases Discovered. Procedures Revised to Require Estimates of Any Flow Through Stack If Fan Flow Indicator R-1254 Inoperable
| 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000362/LER-1985-010-01, :on 850329,w/unit at 96% Power,Reactor Tripped. Caused by Two Failures in Reactor Protection Sys Circuitry. Relay from Channel a Steam Generator Low Flow Bistable & Setpoint Card Replaced |
- on 850329,w/unit at 96% Power,Reactor Tripped. Caused by Two Failures in Reactor Protection Sys Circuitry. Relay from Channel a Steam Generator Low Flow Bistable & Setpoint Card Replaced
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000361/LER-1985-010, :on 850321,31 & 0407,spurious Actuation of Toxic Gas Isolation Sys Train a Occurred.Caused by Conditions Including Overly Conservative Alarm Setpoints, Electrical Noise Levels & Rapid Temp |
- on 850321,31 & 0407,spurious Actuation of Toxic Gas Isolation Sys Train a Occurred.Caused by Conditions Including Overly Conservative Alarm Setpoints, Electrical Noise Levels & Rapid Temp
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(3) |
| 05000206/LER-1985-011-02, :on 850501,main Feedwater Pump Inboard Motor Bearing Sounded High Temp Alarm.Caused by Shaft Fracture in Threaded Region Resulting from Cyclic Fatigue.Pump Overhauled.New Shaft & Impeller Installed |
- on 850501,main Feedwater Pump Inboard Motor Bearing Sounded High Temp Alarm.Caused by Shaft Fracture in Threaded Region Resulting from Cyclic Fatigue.Pump Overhauled.New Shaft & Impeller Installed
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) |
| 05000362/LER-1985-011-01, :on 850401,containment Purge Isolation Sys Train B Actuated.Caused by Failed Power Supply Bridge Diode. Diode Replaced |
- on 850401,containment Purge Isolation Sys Train B Actuated.Caused by Failed Power Supply Bridge Diode. Diode Replaced
| 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000361/LER-1985-011, :on 850122,during Maint Outage,Isolation Valves on East Side of Fire Water Sys Loop Closed While Valves on West Side Closed.Caused by Personnel Error.Procedures Reviewed |
- on 850122,during Maint Outage,Isolation Valves on East Side of Fire Water Sys Loop Closed While Valves on West Side Closed.Caused by Personnel Error.Procedures Reviewed
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000206/LER-1985-012-02, :on 850616,east Vacuum Pump Never Came Out of Starting Current.Caused by Malfunction of Breaker 52-1117. Breaker Being Repaired |
- on 850616,east Vacuum Pump Never Came Out of Starting Current.Caused by Malfunction of Breaker 52-1117. Breaker Being Repaired
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000362/LER-1985-012-01, :on 850404,reactor Tripped on Loss of Load Channels 1 & 4,turbine Governor Fault Alarm Came in & Cleared & RCS Sample Analysis Indicated Specific Activity Exceeded 1.0 Mci/G Dose Equivalent I-131 |
- on 850404,reactor Tripped on Loss of Load Channels 1 & 4,turbine Governor Fault Alarm Came in & Cleared & RCS Sample Analysis Indicated Specific Activity Exceeded 1.0 Mci/G Dose Equivalent I-131
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000361/LER-1985-012, :on 850319,fire Watch in Electrical Cable Tunnel for Inoperable Fire Suppression Sys Evacuated Due to Smell of Ammonia Gas.Caused by Exhaust Fan Drawing Steam & Ammonia Into Tunnel.Cable Tunnel Ventilated |
- on 850319,fire Watch in Electrical Cable Tunnel for Inoperable Fire Suppression Sys Evacuated Due to Smell of Ammonia Gas.Caused by Exhaust Fan Drawing Steam & Ammonia Into Tunnel.Cable Tunnel Ventilated
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) |
| 05000206/LER-1985-013-02, :on 850719,three Control Rod Position Recorder YR-404 Switches Aligned to Nonindicating Positions.Caused by Procedural Inadequacy & Lack of Training.Bypass Switch Use Restricted & Training Planned |
- on 850719,three Control Rod Position Recorder YR-404 Switches Aligned to Nonindicating Positions.Caused by Procedural Inadequacy & Lack of Training.Bypass Switch Use Restricted & Training Planned
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(1) |
| 05000362/LER-1985-013-01, :on 850408,reactor Shut Down Due to Turbine Trip Initiated by Low Seal oil-to-gas Differential.Caused by Failed Pipe Fitting in Generator Hydrogen Seal Oil Sys. Fitting Removed & Replaced |
- on 850408,reactor Shut Down Due to Turbine Trip Initiated by Low Seal oil-to-gas Differential.Caused by Failed Pipe Fitting in Generator Hydrogen Seal Oil Sys. Fitting Removed & Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000361/LER-1985-013, :on 850130,control Room Isolation Sys Train B Spuriously Actuated by Instrument Failure on Control Room Radiation Monitor.Caused by Background Radiation Levels Dropping Below Instrument Failure Setpoint |
- on 850130,control Room Isolation Sys Train B Spuriously Actuated by Instrument Failure on Control Room Radiation Monitor.Caused by Background Radiation Levels Dropping Below Instrument Failure Setpoint
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000206/LER-1985-014-02, :on 850919,reactor Tripped in Response to Turbine Trip.Turbine Trip Caused by Too Rapid Rate of Pressure Increase in Auxiliary Transformer B.Nitrogen Addition Operations Revised |
- on 850919,reactor Tripped in Response to Turbine Trip.Turbine Trip Caused by Too Rapid Rate of Pressure Increase in Auxiliary Transformer B.Nitrogen Addition Operations Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) |
| 05000362/LER-1985-014-01, :on 850418,Train B Containment Purge Isolation Sys Actuated on High Iodine Signal from Containment Airborne Radiation Monitor 3RE-7807A2 (Iodine Channel).Caused by Failure of High Voltage Power Supply Card |
- on 850418,Train B Containment Purge Isolation Sys Actuated on High Iodine Signal from Containment Airborne Radiation Monitor 3RE-7807A2 (Iodine Channel).Caused by Failure of High Voltage Power Supply Card
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000206/LER-1985-015-02, :on 851024,discovered Two Holes,Apparently Caused by Grinding in Stack Sample Line for Particulate Monitor R-1211 & Noble Gas Monitor R-1212.Holes Temporarily Repaired |
- on 851024,discovered Two Holes,Apparently Caused by Grinding in Stack Sample Line for Particulate Monitor R-1211 & Noble Gas Monitor R-1212.Holes Temporarily Repaired
| 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000362/LER-1985-015-01, :on 850422,turbine Plant Area Sump Monitor 3RT-7821 Found Isolated Since 850419.Caused by Operator Error.Procedures Changed to Prevent Recurrence |
- on 850422,turbine Plant Area Sump Monitor 3RT-7821 Found Isolated Since 850419.Caused by Operator Error.Procedures Changed to Prevent Recurrence
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000361/LER-1985-015, :on 850121,discovered That Tech Spec Table 3.7-4b Did Not Reflect Actual Number & Size of Snubbers Installed.Caused by Design Changes Not Being Reflected in Table.Amend to Tech Specs Submitted |
- on 850121,discovered That Tech Spec Table 3.7-4b Did Not Reflect Actual Number & Size of Snubbers Installed.Caused by Design Changes Not Being Reflected in Table.Amend to Tech Specs Submitted
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(i)(8) 10 CFR 50.73(a)(2)(1) |
| 05000206/LER-1985-016-02, :on 851024,fire Protection Deluge Sys for Generator Hydrogen Seal Oil Sys Failed During Surveillance Test.Caused by Rust in Piping Sys.Nozzles Cleaned & Piping Blown Out W/High Pressure Air |
- on 851024,fire Protection Deluge Sys for Generator Hydrogen Seal Oil Sys Failed During Surveillance Test.Caused by Rust in Piping Sys.Nozzles Cleaned & Piping Blown Out W/High Pressure Air
| 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(1) |
| 05000362/LER-1985-016-01, :on 850417,continuous Azimuthal Power Tilt Surveillance Discovered to Be Insufficient.Caused by Inadequate Procedural Guidance to Ensure Continuous Surveillance.Procedures Adjusted |
- on 850417,continuous Azimuthal Power Tilt Surveillance Discovered to Be Insufficient.Caused by Inadequate Procedural Guidance to Ensure Continuous Surveillance.Procedures Adjusted
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000361/LER-1985-016, :on 850131,fuel Handling Isolation Sys Train B Actuated Due to Instrument Failure of Fuel Handling Area Vent Radiation Indicator 2R-7823.Caused by High Voltage Power Supply Loss When HV Pushbutton Released |
- on 850131,fuel Handling Isolation Sys Train B Actuated Due to Instrument Failure of Fuel Handling Area Vent Radiation Indicator 2R-7823.Caused by High Voltage Power Supply Loss When HV Pushbutton Released
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000206/LER-1985-017-01, :on 851121,reactor Tripped Due to Loss of Power to safety-related Buses.Event Investigated by Util & NRC Incident Investigation Team.Results Presented on 860122 & Published in NUREG-1190 |
- on 851121,reactor Tripped Due to Loss of Power to safety-related Buses.Event Investigated by Util & NRC Incident Investigation Team.Results Presented on 860122 & Published in NUREG-1190
| |
| 05000206/LER-1985-017-02, :on 851121,reactor Manually Tripped in Response to Loss of Vital Bus 4 Power.Vital Bus Lost Power When Station Reserve Auxiliary Transformer Tripped by Relay Protection Circuitry.Cause Under Investigation |
- on 851121,reactor Manually Tripped in Response to Loss of Vital Bus 4 Power.Vital Bus Lost Power When Station Reserve Auxiliary Transformer Tripped by Relay Protection Circuitry.Cause Under Investigation
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000362/LER-1985-017, :on 850417,failed Pacific Scientific Mechanical Snubber Discovered.Damage Caused by Hydraulic Transient. Addl Snubbers Manually Stroked & All Deficient Snubbers Replaced |
- on 850417,failed Pacific Scientific Mechanical Snubber Discovered.Damage Caused by Hydraulic Transient. Addl Snubbers Manually Stroked & All Deficient Snubbers Replaced
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) |
| 05000362/LER-1985-017-01, :on 850417,failed Pacific Scientific Snubber Discovered in Routine post-maint Surveillance.Caused by Hydraulic Transient Damage.Snubber Replaced & 29 Addl Snubbers Checked.Deficient Snubbers Replaced |
- on 850417,failed Pacific Scientific Snubber Discovered in Routine post-maint Surveillance.Caused by Hydraulic Transient Damage.Snubber Replaced & 29 Addl Snubbers Checked.Deficient Snubbers Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) |
| 05000361/LER-1985-017, :on 850203,7-day Functional Channel Surveillance Test for Source Range Neutron Flux Monitors Exceeded Tech Spec Time Limit.Caused by Personnel Error. Test Completed & Review in Progress |
- on 850203,7-day Functional Channel Surveillance Test for Source Range Neutron Flux Monitors Exceeded Tech Spec Time Limit.Caused by Personnel Error. Test Completed & Review in Progress
| 10 CFR 50.73(a)(2)(1) |
| 05000361/LER-1985-018-01, :on 850820,reactor Tripped in Response to Trip Signals from Channels 1 & 3 of Core Protection Calculators. Caused by Inadequate Guidance in 31-day Surveillance Testing Procedure.Procedures Revised |
- on 850820,reactor Tripped in Response to Trip Signals from Channels 1 & 3 of Core Protection Calculators. Caused by Inadequate Guidance in 31-day Surveillance Testing Procedure.Procedures Revised
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) |
| 05000362/LER-1985-018, :on 850502,Train a Containment Purge Isolation Sys Logic Circuit Actuated on High Iodine Signal from Containment Airborne Radiation Monitor.Caused by Buildup of Iodine on Charcoal Filter.Filter Replaced |
- on 850502,Train a Containment Purge Isolation Sys Logic Circuit Actuated on High Iodine Signal from Containment Airborne Radiation Monitor.Caused by Buildup of Iodine on Charcoal Filter.Filter Replaced
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) |
| 05000361/LER-1985-019, :on 850517,fuel Handling Isolation Sys Actuated by Spurious Airborne Monitor Alarm.Probably Caused by Radiation Monitor Detector Sensitivity.Spurious Actuations Also Occurred on 850519,26 & 0607 |
- on 850517,fuel Handling Isolation Sys Actuated by Spurious Airborne Monitor Alarm.Probably Caused by Radiation Monitor Detector Sensitivity.Spurious Actuations Also Occurred on 850519,26 & 0607
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) |
| 05000362/LER-1985-019-01, :on 850517,actuation of Fuel Handling Isolation Sys Train a Occurred When Airborne Monitor 3RE-7822 Spuriously Alarmed.Addl Spurious Actuations Occurred on 850519,850526 & 850607 |
- on 850517,actuation of Fuel Handling Isolation Sys Train a Occurred When Airborne Monitor 3RE-7822 Spuriously Alarmed.Addl Spurious Actuations Occurred on 850519,850526 & 850607
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(1) 10 CFR 50.73(a)(2)(viii)(8) |
| 05000362/LER-1985-020-01, :on 850524,unit Tripped from 100% Power by Core Protection Calculators in Response to Core Element Assembly Subgroup 15.Caused by Blown Fuse in Hold Bus Logic Circuit.Fuse Replaced & Unit Returned to Svc |
- on 850524,unit Tripped from 100% Power by Core Protection Calculators in Response to Core Element Assembly Subgroup 15.Caused by Blown Fuse in Hold Bus Logic Circuit.Fuse Replaced & Unit Returned to Svc
| 10 CFR 50.73(a)(2)(iv), System Actuation |
| 05000361/LER-1985-020, :on 850210,Train B of Toxic Gas Isolation Sys Actuated.Caused by Failure of Fitting in Hydrocarbon Analyzer.Fitting Repaired & Sys Returned to Svc on 850211 |
- on 850210,Train B of Toxic Gas Isolation Sys Actuated.Caused by Failure of Fitting in Hydrocarbon Analyzer.Fitting Repaired & Sys Returned to Svc on 850211
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(B) 10 CFR 50.73(a)(2)(1) |
| 05000362/LER-1985-021, :on 850616,actuation of Fuel Handling Isolation Sys Train B Occurred When Airborne Monitor Alarmed.Caused by Increase in Background Radiation Level Due to Noble Gas Leak from Loose Fitting.Fitting Tightened |
- on 850616,actuation of Fuel Handling Isolation Sys Train B Occurred When Airborne Monitor Alarmed.Caused by Increase in Background Radiation Level Due to Noble Gas Leak from Loose Fitting.Fitting Tightened
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) 10 CFR 50.73(a)(2)(viii)(A) 10 CFR 50.73(a)(2)(viii)(B) |