| 05000458/LER-1985-001, :on 850831,reactor Protection Sys Actuated on High Source Range Monitor Counts.Caused by Core Geometry Change When Fuel Initial Bundle Placed in Core.Four Fuel Loading Chambers Relocated to Eliminate High Count |
- on 850831,reactor Protection Sys Actuated on High Source Range Monitor Counts.Caused by Core Geometry Change When Fuel Initial Bundle Placed in Core.Four Fuel Loading Chambers Relocated to Eliminate High Count
| |
| 05000458/LER-1985-002, :on 850904,reactor Protection Sys Actuated on High Main Steam Line Radiation & High Scram Discharge Vol Level.Caused by Reactor Protection Sys Channel a Manual Trip During Calibr Coupled W/Inadvertent Noise Spikes |
- on 850904,reactor Protection Sys Actuated on High Main Steam Line Radiation & High Scram Discharge Vol Level.Caused by Reactor Protection Sys Channel a Manual Trip During Calibr Coupled W/Inadvertent Noise Spikes
| |
| 05000458/LER-1985-003, :on 850904,full Reactor Protection Sys Actuation Occurred.Caused by Unintentional Shorting of Contact While Attempting to Install Jumper.Fuse C71-F7A Replaced & Jumpers Moved to Terminal Blocks |
- on 850904,full Reactor Protection Sys Actuation Occurred.Caused by Unintentional Shorting of Contact While Attempting to Install Jumper.Fuse C71-F7A Replaced & Jumpers Moved to Terminal Blocks
| |
| 05000458/LER-1985-004, :on 850906,discovered That APRM Weekly Reactor Protection Sys Tests for Channels B,D,E,G & H Unsatisfactory Per Requirements for Setdown Neutron Trip.Caused by Exclusion of Steps to Verify Half Scram |
- on 850906,discovered That APRM Weekly Reactor Protection Sys Tests for Channels B,D,E,G & H Unsatisfactory Per Requirements for Setdown Neutron Trip.Caused by Exclusion of Steps to Verify Half Scram
| |
| 05000458/LER-1985-005, :on 850913,reactor Protection Sys Actuation Occurred.Caused by Operator Error When Intermediate Range Monitor Channel E Mode Switch Inadvertently Moved from Operate to Standby.Switch Placed in Operate Position |
- on 850913,reactor Protection Sys Actuation Occurred.Caused by Operator Error When Intermediate Range Monitor Channel E Mode Switch Inadvertently Moved from Operate to Standby.Switch Placed in Operate Position
| |
| 05000458/LER-1985-006, :on 850916,reactor Protection Sys Actuated While in Noncoincident Trip Mode When Malfunction in Undervoltage Printed Circuit Board on Alternate Supply Breaker Tripped Electrical Protection Assembly |
- on 850916,reactor Protection Sys Actuated While in Noncoincident Trip Mode When Malfunction in Undervoltage Printed Circuit Board on Alternate Supply Breaker Tripped Electrical Protection Assembly
| |
| 05000458/LER-1985-007, :on 850919,replacement Level Transmitter for Scram Discharge Vol Did Not Meet IEEE Std 323-1974 Qualifications.Caused by Maint Personnel Not Using Controlled Documents to Specify Replacement |
- on 850919,replacement Level Transmitter for Scram Discharge Vol Did Not Meet IEEE Std 323-1974 Qualifications.Caused by Maint Personnel Not Using Controlled Documents to Specify Replacement
| |
| 05000458/LER-1985-008, :on 850923,during Refueling,Reactor Protection Sys Actuated Due to Water Level Below Level 3 Scram Setpoint.Caused by Inadequate Procedure & Operator Error. Reactor Pressure Vessel Level Reestablished |
- on 850923,during Refueling,Reactor Protection Sys Actuated Due to Water Level Below Level 3 Scram Setpoint.Caused by Inadequate Procedure & Operator Error. Reactor Pressure Vessel Level Reestablished
| |
| 05000458/LER-1985-009, :on 850926,reactor Water Cleanup Containment Isolation Initiated When Temp Reading Obtained from Leak Detection Differential Temp Switch.Caused by Flaw in Switch Design.Mfg Mod to Circuitry Recommended |
- on 850926,reactor Water Cleanup Containment Isolation Initiated When Temp Reading Obtained from Leak Detection Differential Temp Switch.Caused by Flaw in Switch Design.Mfg Mod to Circuitry Recommended
| |
| 05000458/LER-1985-010, :on 850930,explosive Valve Failed to Fire When Train a of Standby Liquid Control Sys Initiated.Caused by Incorrectly Wired Terminations in Termination Panel. Terminations Corrected |
- on 850930,explosive Valve Failed to Fire When Train a of Standby Liquid Control Sys Initiated.Caused by Incorrectly Wired Terminations in Termination Panel. Terminations Corrected
| |
| 05000458/LER-1985-011, :on 850930,both Divs of Secondary & Primary Containment Isolation Spuriously Actuated.Caused by Testing Which Generated Div II MSIV Isolation Signal.Testing Reperformed & No Isolations Occurred |
- on 850930,both Divs of Secondary & Primary Containment Isolation Spuriously Actuated.Caused by Testing Which Generated Div II MSIV Isolation Signal.Testing Reperformed & No Isolations Occurred
| |
| 05000458/LER-1985-012, :on 851003,potential for Loss of Power to Transfer Circuitry for Remote Shutdown Capability & Apparent Excessive Voltage Drop in Control Circuitry Existed W/Div 1 Standby Switchgear.Transfer Relays Replaced |
- on 851003,potential for Loss of Power to Transfer Circuitry for Remote Shutdown Capability & Apparent Excessive Voltage Drop in Control Circuitry Existed W/Div 1 Standby Switchgear.Transfer Relays Replaced
| |
| 05000458/LER-1985-013, :on 851012,remote Shutdown Panel Dc Power Supply in Main Control Room Located.Caused by Design Deficiency.Mod Request Initiated to Utilize Alternate Power Supply Outside Main Control Room |
- on 851012,remote Shutdown Panel Dc Power Supply in Main Control Room Located.Caused by Design Deficiency.Mod Request Initiated to Utilize Alternate Power Supply Outside Main Control Room
| |
| 05000458/LER-1985-014, :on 851018,standby Cooling Tower Level Discovered Below Min Tech Spec Requirement of 78%.Caused by Operator Error During Manual Operations of Standby Svc Water Sys.Procedure SOP-0018 Revised |
- on 851018,standby Cooling Tower Level Discovered Below Min Tech Spec Requirement of 78%.Caused by Operator Error During Manual Operations of Standby Svc Water Sys.Procedure SOP-0018 Revised
| |
| 05000458/LER-1985-015, :on 851013,Channels a & B of Control Room Ventilation Local Intake Radiation Monitors Discovered Inoperable.Caused by Sample Pump Trip Following Offsite Power Excursion.Pumps Restarted |
- on 851013,Channels a & B of Control Room Ventilation Local Intake Radiation Monitors Discovered Inoperable.Caused by Sample Pump Trip Following Offsite Power Excursion.Pumps Restarted
| |
| 05000458/LER-1985-016, :on 851024,ESF Isolation of Shutdown Cooling Suction Valve Occurred.Caused by Jumper Slipping Off Terminal & Blowing Fuse During Surveillance Test.Fuse Replaced.Banana Plugs Installed |
- on 851024,ESF Isolation of Shutdown Cooling Suction Valve Occurred.Caused by Jumper Slipping Off Terminal & Blowing Fuse During Surveillance Test.Fuse Replaced.Banana Plugs Installed
| |
| 05000458/LER-1985-017, :on 851025,ESF Isolation of Shutdown Cooling Section Valve Occurred.Caused by Inadvertent Grounding of Recorder Lead During Attempt to Attach to Relay Terminal. Fuse Replaced.Procedure STP-204-0602 Revised |
- on 851025,ESF Isolation of Shutdown Cooling Section Valve Occurred.Caused by Inadvertent Grounding of Recorder Lead During Attempt to Attach to Relay Terminal. Fuse Replaced.Procedure STP-204-0602 Revised
| |
| 05000458/LER-1985-018, :on 851021,RHR Sys Loop a Isolation Occurred. Caused by Technician Mistakenly Connecting Lead to Wrong Relay & Then Misinterpreting Relay Drawings.Isolation Reset. Test Jacks Added to Terminals |
- on 851021,RHR Sys Loop a Isolation Occurred. Caused by Technician Mistakenly Connecting Lead to Wrong Relay & Then Misinterpreting Relay Drawings.Isolation Reset. Test Jacks Added to Terminals
| |
| 05000458/LER-1985-019, :on 851022,Div II RWCU Isolation Occurred. Caused by Loose Jumper Resulting in Shorted & Blown Fuse. Fuse Replaced & Isolation Reset |
- on 851022,Div II RWCU Isolation Occurred. Caused by Loose Jumper Resulting in Shorted & Blown Fuse. Fuse Replaced & Isolation Reset
| |
| 05000458/LER-1985-020, :on 851028,Div I RWCU Isolation Occurred W/Plant in Operational Condition 4 (Cold Shutdown) & Prior to Initial Criticality.Caused by Blown Fuse |
- on 851028,Div I RWCU Isolation Occurred W/Plant in Operational Condition 4 (Cold Shutdown) & Prior to Initial Criticality.Caused by Blown Fuse
| |
| 05000458/LER-1985-021, :on 851022,during Surveillance Testing on HPCS Drywell High Pressure Transmitter,Initiation of HPCS Sys Occurred.Probably Caused by Misplaced Test Lead Shorting Trip Unit.Control Technicians Counseled |
- on 851022,during Surveillance Testing on HPCS Drywell High Pressure Transmitter,Initiation of HPCS Sys Occurred.Probably Caused by Misplaced Test Lead Shorting Trip Unit.Control Technicians Counseled
| |
| 05000458/LER-1985-022, :on 851023,Div II RWCU Isolation Occurred. Caused by Failure of Procedure to Specify Terminals to Be Jumpered in Order to Bypass Isolation Signal.Procedure Revised to Identify Correct Set of Connections |
- on 851023,Div II RWCU Isolation Occurred. Caused by Failure of Procedure to Specify Terminals to Be Jumpered in Order to Bypass Isolation Signal.Procedure Revised to Identify Correct Set of Connections
| |
| 05000458/LER-1985-023, :on 851024,Div II RWCU Isolation Occurred. Caused by Blown Fuse Due to Jumper Falling Off Relay Terminal & Shorting to Ground.Fuse Replaced & Isolation Reset |
- on 851024,Div II RWCU Isolation Occurred. Caused by Blown Fuse Due to Jumper Falling Off Relay Terminal & Shorting to Ground.Fuse Replaced & Isolation Reset
| |
| 05000458/LER-1985-024, :on 851024,w/plant in Cold Shutdown Prior to Initial Criticality,Rwcu Isolated Due to Unstable High Differential Flow Readings.Caused by Flashing Downstream of Blowdown Orifice.Orifice Resized |
- on 851024,w/plant in Cold Shutdown Prior to Initial Criticality,Rwcu Isolated Due to Unstable High Differential Flow Readings.Caused by Flashing Downstream of Blowdown Orifice.Orifice Resized
| |
| 05000458/LER-1985-025, :on 851024 & 26 Reactor Water Conductivity Measurements Not Taken as Required.Caused by Chemistry & Operations Unaware That Surveillance Required by Tech Specs. Technicians Counseled on Procedures |
- on 851024 & 26 Reactor Water Conductivity Measurements Not Taken as Required.Caused by Chemistry & Operations Unaware That Surveillance Required by Tech Specs. Technicians Counseled on Procedures
| |
| 05000458/LER-1985-026, :on 851024,ECCS Actuation Occurred Due to Inadvertent Venting of Low Pressure Side of Reactor Vessel Level Instrument.Caused by Incorrect Instructions & Failure to Understand Impact of Actions |
- on 851024,ECCS Actuation Occurred Due to Inadvertent Venting of Low Pressure Side of Reactor Vessel Level Instrument.Caused by Incorrect Instructions & Failure to Understand Impact of Actions
| |
| 05000458/LER-1985-027, :on 851027,ESF Actuation Occurred on Div 1 ECCS Due to Erroneous Reactor Vessel Low Level Signal. Caused by Personnel Backfilling Level Instrument W/Common Ref Leg |
- on 851027,ESF Actuation Occurred on Div 1 ECCS Due to Erroneous Reactor Vessel Low Level Signal. Caused by Personnel Backfilling Level Instrument W/Common Ref Leg
| |
| 05000458/LER-1985-028, :on 851030,main Supply Breaker in 13.8 Kv Normal Switchgear Mistakenly Tripped,Causing Several Actuations.Caused by Personnel Error.Equipment Returned to Normal Operation |
- on 851030,main Supply Breaker in 13.8 Kv Normal Switchgear Mistakenly Tripped,Causing Several Actuations.Caused by Personnel Error.Equipment Returned to Normal Operation
| |
| 05000458/LER-1985-029, :on 851031,isolation of Div 1 RWCU Sys Occurred Causing Closing of Four Outboard Isolation Valves.Caused by Spurious Opening of Contacts on Riley Temp Modules.Mods to Temp Modules to Reduce Transient Susceptibility Begun |
- on 851031,isolation of Div 1 RWCU Sys Occurred Causing Closing of Four Outboard Isolation Valves.Caused by Spurious Opening of Contacts on Riley Temp Modules.Mods to Temp Modules to Reduce Transient Susceptibility Begun
| |
| 05000458/LER-1985-030, :on 851101,Div 1 RWCU Sys Isolation Occurred. Caused by Spurious Rwcs Filter Demineralizer Room 1 High Temp Alarm.Rwcu Sys Placed Back in Operation.Mod in Progress to Correct Flashing & Noise Spiking Problems |
- on 851101,Div 1 RWCU Sys Isolation Occurred. Caused by Spurious Rwcs Filter Demineralizer Room 1 High Temp Alarm.Rwcu Sys Placed Back in Operation.Mod in Progress to Correct Flashing & Noise Spiking Problems
| |
| 05000458/LER-1985-031, :on 851101,Div 1 RWCU Isolation Occurred.Caused by Actuation of Area Selection Switch When Operator Took RWCU Room Temps for Surveillance Test Procedure STP-000-001 & Failed to Place Switch in Bypass.Isolation Reset |
- on 851101,Div 1 RWCU Isolation Occurred.Caused by Actuation of Area Selection Switch When Operator Took RWCU Room Temps for Surveillance Test Procedure STP-000-001 & Failed to Place Switch in Bypass.Isolation Reset
| |
| 05000458/LER-1985-032, :on 851103,fuel Bldg HVAC Normal Supply & Exhaust Sys Isolated & Div I ESF Charcoal Filter Train Auto Started.Caused by Spurious Low Flow Signal Being Generated by Div I Flow Switch.Switch Recalibr |
- on 851103,fuel Bldg HVAC Normal Supply & Exhaust Sys Isolated & Div I ESF Charcoal Filter Train Auto Started.Caused by Spurious Low Flow Signal Being Generated by Div I Flow Switch.Switch Recalibr
| |
| 05000458/LER-1985-033, :on 851108,36 Electrical Junction Boxes Discovered Not Sealed as Required for Environ Qualification. Caused by Assignment & Tracking of Generic Work Activity by Bldg Rather than Individual Punch Lists |
- on 851108,36 Electrical Junction Boxes Discovered Not Sealed as Required for Environ Qualification. Caused by Assignment & Tracking of Generic Work Activity by Bldg Rather than Individual Punch Lists
| |
| 05000458/LER-1985-034, :on 851113,standby Svc Water Sys Declared Inoperable & Unit Manually Scrammed Upon Discovery That Category 1 Structural Elements Not Installed in Piping Tunnels G & H.Work Completed by 851114 |
- on 851113,standby Svc Water Sys Declared Inoperable & Unit Manually Scrammed Upon Discovery That Category 1 Structural Elements Not Installed in Piping Tunnels G & H.Work Completed by 851114
| |
| 05000458/LER-1985-035, :on 851111,RWCU Isolation Occurred.Caused by Switch Failure on Demineralizer Receiver Tank Room Temp Differential Trip Unit.Switch Replaced |
- on 851111,RWCU Isolation Occurred.Caused by Switch Failure on Demineralizer Receiver Tank Room Temp Differential Trip Unit.Switch Replaced
| |
| 05000458/LER-1985-036, :on 851113,ECCS/ATWS Initiation Occurred During Performance of Surveillance Test on Reactor Level Instrumentation.Caused by Inadvertent Valve Lineup During Surveillance Test.Precautionary Memo Written |
- on 851113,ECCS/ATWS Initiation Occurred During Performance of Surveillance Test on Reactor Level Instrumentation.Caused by Inadvertent Valve Lineup During Surveillance Test.Precautionary Memo Written
| |
| 05000458/LER-1985-037, :on 851117,while in Startup,Erroneous RWCU Isolation Occurred.Caused by Defective Trip Unit.Trip Condition Reset |
- on 851117,while in Startup,Erroneous RWCU Isolation Occurred.Caused by Defective Trip Unit.Trip Condition Reset
| |
| 05000458/LER-1985-038, :on 851115,RWCU Isolation Occurred During Performance of STP-207-4215, RWCU High Differential Flow Channel Functional Test. Caused by Procedure Error. Procedure Revised |
- on 851115,RWCU Isolation Occurred During Performance of STP-207-4215, RWCU High Differential Flow Channel Functional Test. Caused by Procedure Error. Procedure Revised
| |
| 05000458/LER-1985-039, :on 851117,in Operational Condition 2 at 30 Mwt,Rwcu Sys Isolated Due to Unstable High Differential Flow Readings.Caused by Water Flashing at Blowdown Flow Element G33 FEN011.Loop Recalibr |
- on 851117,in Operational Condition 2 at 30 Mwt,Rwcu Sys Isolated Due to Unstable High Differential Flow Readings.Caused by Water Flashing at Blowdown Flow Element G33 FEN011.Loop Recalibr
| |
| 05000458/LER-1985-040, :on 851118,at 2% Power RWCU Sys Isolation Occurred.Caused During Maint Activities When Temp Module Removed W/Bypass Switch in Normal Position.Switch Placed in Bypass Position & Trip Reset |
- on 851118,at 2% Power RWCU Sys Isolation Occurred.Caused During Maint Activities When Temp Module Removed W/Bypass Switch in Normal Position.Switch Placed in Bypass Position & Trip Reset
| |
| 05000458/LER-1985-041, :on 851121,during Startup,Reactor Feedwater Pump (RFP) Tripped.Caused by Main Oil Pump Trip on Overload Due to RFP Discharge motor-operated Valve Torque Switch Set Too Low.Switch Settings Reset |
- on 851121,during Startup,Reactor Feedwater Pump (RFP) Tripped.Caused by Main Oil Pump Trip on Overload Due to RFP Discharge motor-operated Valve Torque Switch Set Too Low.Switch Settings Reset
| |
| 05000458/LER-1985-042, :on 851119,RCIC Steam Line Containment Isolation Occurred During Safety Relief Valve Testing.Caused by Pressure/Flow Fluctuations in Steam Line Due to Lifting of Valves.Damping Potentiometer Adjusted |
- on 851119,RCIC Steam Line Containment Isolation Occurred During Safety Relief Valve Testing.Caused by Pressure/Flow Fluctuations in Steam Line Due to Lifting of Valves.Damping Potentiometer Adjusted
| |
| 05000458/LER-1985-043, :on 851121,reactor Water Cleanup HX Room Temp Switch Trip Setpoint Found Outside Tech Spec Limit.Caused by Error in Approved Surveillance Procedure.Procedure Revised |
- on 851121,reactor Water Cleanup HX Room Temp Switch Trip Setpoint Found Outside Tech Spec Limit.Caused by Error in Approved Surveillance Procedure.Procedure Revised
| |
| 05000458/LER-1985-044, :on 851125,RWCU Sys Isolated Due to High Temp Signal from HX Room.Caused by Failure of Operator to Restore Cooling Water to Containment Coolers in Timely Manner. Procedure AOP-0004 Reviewed for Rev |
- on 851125,RWCU Sys Isolated Due to High Temp Signal from HX Room.Caused by Failure of Operator to Restore Cooling Water to Containment Coolers in Timely Manner. Procedure AOP-0004 Reviewed for Rev
| |
| 05000458/LER-1985-045, :on 851126,Div III ECCS Initiation & Injection Occurred.Caused by Improperly Valving Transmitter Into Svc During Surveillance Test Procedure.Pump Secured & Valve Closed.Procedure Clarified.Staff Counseled |
- on 851126,Div III ECCS Initiation & Injection Occurred.Caused by Improperly Valving Transmitter Into Svc During Surveillance Test Procedure.Pump Secured & Valve Closed.Procedure Clarified.Staff Counseled
| |
| 05000458/LER-1985-046, :on 851128,MSIV Containment Isolation Occurred Due to Taking Temp Reading on Leak Detection Differential Temp Switch.Caused by Design Problem W/Temp Switch Type.Mod in Progress |
- on 851128,MSIV Containment Isolation Occurred Due to Taking Temp Reading on Leak Detection Differential Temp Switch.Caused by Design Problem W/Temp Switch Type.Mod in Progress
| |
| 05000458/LER-1985-047, :on 851128,reactor Scrammed on intermediate- Range Monitor Upscale Trip Due to Reactor Water Pressure/ Transients Introduced by Breaking Condenser Vacuum.Caused by Cold Water Injection |
- on 851128,reactor Scrammed on intermediate- Range Monitor Upscale Trip Due to Reactor Water Pressure/ Transients Introduced by Breaking Condenser Vacuum.Caused by Cold Water Injection
| |
| 05000458/LER-1985-048, :on 851202,inadvertent RWCU Isolation Occurred. Caused by Operating Defective Temp Switch Module W/O RWCU Isolation Switch in Bypass Position While Performing Surveillance Procedure |
- on 851202,inadvertent RWCU Isolation Occurred. Caused by Operating Defective Temp Switch Module W/O RWCU Isolation Switch in Bypass Position While Performing Surveillance Procedure
| |
| 05000458/LER-1985-049, :on 851206,RCIC Steam Line Containment Isolation Occurred While Testing Safety Relief Valves. Caused by Lifting of Valves Resulting in Pressure/Flow Fluctuations in Steam Line.Isolation Reset |
- on 851206,RCIC Steam Line Containment Isolation Occurred While Testing Safety Relief Valves. Caused by Lifting of Valves Resulting in Pressure/Flow Fluctuations in Steam Line.Isolation Reset
| |
| 05000458/LER-1985-050, :on 851203,discovered That RHR Pump & Valve Operability Quarterly Surveillances Missed for Subsys a, B & C During Last Surveillance Interval.Caused by Scheduling Error.Surveillances Performed |
- on 851203,discovered That RHR Pump & Valve Operability Quarterly Surveillances Missed for Subsys a, B & C During Last Surveillance Interval.Caused by Scheduling Error.Surveillances Performed
| |