05000458/LER-1985-001, :on 850831,reactor Protection Sys Actuated on High Source Range Monitor Counts.Caused by Core Geometry Change When Fuel Initial Bundle Placed in Core.Four Fuel Loading Chambers Relocated to Eliminate High Count

From kanterella
(Redirected from 05000458/LER-1985-001)
Jump to navigation Jump to search
:on 850831,reactor Protection Sys Actuated on High Source Range Monitor Counts.Caused by Core Geometry Change When Fuel Initial Bundle Placed in Core.Four Fuel Loading Chambers Relocated to Eliminate High Count
ML20138A506
Person / Time
Site: River Bend 
Issue date: 09/30/1985
From: Williamson D
GULF STATES UTILITIES CO.
To:
Shared Package
ML20138A454 List:
References
LER-85-001, LER-85-1, NUDOCS 8510080578
Download: ML20138A506 (2)


LER-1985-001, on 850831,reactor Protection Sys Actuated on High Source Range Monitor Counts.Caused by Core Geometry Change When Fuel Initial Bundle Placed in Core.Four Fuel Loading Chambers Relocated to Eliminate High Count
Event date:
Report date:
4581985001R00 - NRC Website

text

[

3

=xC e.,= 3ee u a mucLEAa KlaulAfoav Ccme..ssion APNtovEO owe.so 3:30 4 04 LICENSEE EVENT REPORT (LER)

  • ACiuty hAus ni oocaat muustm 12)

C* 3 i m 0 l 5 l 0 l 0 l 0 l.3 l c,l g 1lOFlgj2 p ; vn,. pg,,a q,n,;nn Tif LE tel D s' 9 r* t n ? D v n t r4

  • t i n Y1 SVCtPM dC'?119iION9 SvthT DAf t 184 L't e huai.s t a to atPORT Daft 171 oTHE R F ACILITit8 INv0Lvt0 tes MCNTn cay vtan vtan sac e s Qv y ggH g,,

yg,q paCsLaT V NewES DOCat T Nuustmes) 0l5l0l0[0; ; l n lc 3l 1 8

5 8 l5 0 l0 l 1 0 l0 0 l9 3l0 8l5

~

~

0 1 5l0goiog i i Tms atPont is sueuiTTEo PunsuA=7 To fuI atoviatut=n on to C,= g iCa-.

---..,ia. s.w nu "O*' i'i c;

a ao2: i n.c.i.i m.e.ainini y

so nwu2Hm noi oin I n 2* mi"H88

= eini

.a n..uH.,

n ti,.i g

ruiisi mm*2' so n.H2H i o.fwi n.a,. r+.,r=. na--,

er A

s..

cw 20 406(ell 1Hieu 94.7 3t.H2Hil to 734eH2Hvii4H Al JsdA)

M 406talt1HM

$4 73W2Hal 30.73<.H2tivialiel 20 40Sf.Illifvl 90 7341I2HM to 73'eH2H=1 LICt%85 t CONT ACT FOR THl4 LI4 02)

%Auf TELEPwCNE muustm amie CCCE n_w. willin-Cnn 51 0 l!

31416 I 8161 51 1 _

COMPLtit 044 Liht F04 E ACH CCAaPO4847 F AILURE Dt9ChistD IN TMit REPCRT (12)

CA035 SYSTEW CowPCNt%T To em I CAult Sv5 TEM CCMPCNE N T

[

g",I,"[j '

T-t I

I I I i 1 1 I

I I I l l I I

I l l I I l l

I I l l I I SUPPLEMt4TAL RIPomt isPtCTIO 114#

WONTH DAY vtan Sv t u' $5 tO%

VL1(19 v terwee EM9tCTED SG0ur$31CN CA TEl

%O T. ACT mm,, =

. %.,.. - i M.,

l l

l At 0350 on 8-31-85, with the unit suberitical during t!.c performance of 1-ST-3 (Fuel Load), the Reactor Protection System actuated on liigh Source Range Monitor (SRM)

This was caused by the core geometry change when the initial fuel bundle was counts.

placed in the core.

The operator on the refueling platform relocated the four fuel loading chambers in the core to eliminate the liigh SRM counts. The health and safety of the public was not affected.

8510080578 850930 PDR ADOCK 05000458 S

PDR mac Form JOS 19 43)

I

8

%EC Fee

  • 3s44 U S Nuclean neoutatomy Cowwitsion LICENSEE EVENT REPORT (LER) TEXT CONTINUATION i
      • aoven ove %o u w ow.

i. e.a s s a n.5 8&Citif Y NAW4 IM pucalTNUWetRIU Le e %v&SS R 16#

PAGG 834 "R:,W" Ta'.Y "aa River Bend Station o l5 [ 0 l 0 l 0 l 415 l 8 8l5 O h l1 01 0 0l>

0' o l?

sww -.==

sace mawnn On 8-31-85, with-the unit suberitical, Operations was performing 1-ST-3 (Fuel Load).

During the performance of this procedure, the Reactor Protection system (RPS) actuated on liigh Source Range Monitor (SRM) counts due to the high count rate on Fuel Load Chamber (FLC) "D".

This occurred when the initial fuel bundle was placed in the core.

The causes of this RPS actuation were the geometry of the fuel bundles, the sources and thg fuel loading chambers together with the lower SRM scram setpoint of 2 X 10 cps.

Because these conservative parameters were dictated by 1-ST-3, which is consistent with USNRC Regulatory Guide 1.68, Technical Specifications, and the River Bend FSAR, the RPS actuation was unavoidable.

The corrective action taken by Operations was to relocate the four FLCs to locations in the core at sufficient distances from the sources and the fuel cells being loaded.

ro.

>.e.