ML20137Z493

From kanterella
Jump to navigation Jump to search
Five-Yr Summary Survey Rept, Including TLD Monitoring, Direct Radiation Survey,Contamination Survey Results,Environ Sample Analysis Rept & Leak Deck Plans
ML20137Z493
Person / Time
Site: NS Savannah
Issue date: 08/20/1985
From:
SOUTH CAROLINA, STATE OF
To:
Shared Package
ML20137Z445 List:
References
NUDOCS 8510080257
Download: ML20137Z493 (19)


Text

__ _.__-__

APPENDIX A N.

S. SAVANNAH Five (5) Year Summary Survey Report Contents:

TLD Monitoring Report Direct Radiation Survey and Contamination Survey Results Environmental Sample Analysis Report Deck Plans

-Conducted By:

South Carolina Department of Health and Environmental Control Bureau of Radiological Health 2600 Bull Street Columbia, South Carolina 29201 5000238 PDR

TLD Badge Locations on the N. S. Savannah TLD No.

Locations 1901 Pilot house - ceiling.

1902 Outside on Promenade deck behind the swimming pool.

1905 Vent on main stairway to Verande and lounge on Promenade deck.

1907 (Upper level) engine room throttle.

1909 In front of the top of the reactor hatch on white column - Promenade deck.

1910 Promenade deck main lounge middle of front viewing window.

1911 "A"

deck main desk behind counter on orange wall.

1912 "A" deck hospital entrance (near H.P. room) on wire cable above wooden wall rack.

1913 "A"

deck near hospital entrance sign.

1914 "B"

deck Cargo Hold #4 on wall near entrance in front of chalk markings on floor.

1915 "B" deck inside Fire Station #20.

1916 "B"

deck handle on door _ leading to reactor space.

1917 "B"

deck door leading to fan room.

1918 "B"

deck main dining room - light fixture near entrance to main galley.

1919 "C" deck Fire Station #28.

1920 Reactor control room and alarm handle.

1921 (Lower level) engine room outside pump charge hatch right side 20 f t.

ahead of diesel engines.

(starboard).

1922 "14 f t. Plat" on right side above stabilizer door (starboard).

1923 "D"

deck Fire Station #31.

1924

" Hold" left side near alarm bell (portside).

1925

" Hold" on pipe near alarm right side (starboard).

1926 Navigation bridge deck - officer's lounge fan.

1927 3rd officer Room NB1 - on metal rack Navigation bridge deck.

1930 Navigation bridge deck - Room NB4.

Reactor operation room on metal rack.

1932 "C" deck door leading to reactor space on overhead pipes.

1933 "C" deck cold chem lab door.

1934 Pipes above stairway to "C" deck from "D" deck.

1936 "14ft. Plat" above left side of stabilizer door (portside).

1938 (Lower level) engine room outside door of pump hatch changer left side (portside).

1939 "C" deck left side of ceiling in reactor viewing room (portside).

1940 "C" deck right side of ceiling in reactor viewing room (starboard).

1945 Fantail of U.S. Yorktown 1946 Ticket Booth Parking Lot - Patriots Point 1947 U.S.S.

Clagamore (submarine) fantail near N.S.

Savannah 1

/

TLD MONITORING REPORT 1981 - 1985 (Avg. mR/ Day per Year)

TLD Station Number 1981A 1982B 1983B 1984B 1985A 1901 0.08 0.07

  • 0.03 0.11 0.01 0.13 i 0.05 0.17 1902 0.10 0.08 i 0.03 0.09 t 0.04 0.14
  • 0.07 0.15 1905 0.10 0.10 0.03 0.10
  • 0.02 0.12
  • 0.03 0.11 1907 0.07 0.07 i 0.03 0.09 0.05 0.10
  • 0.01 0.10 1909 0.47 0.11 i 0.04 0.10
  • 0.04 0.13 t 0.01 0.11 1910 0.07 0.10 i 0.03 0.11
  • 0.06 0.12
  • 0.02 0.11 1911 0.08 0.10
  • 0.02 0.12
  • 0.04 0.15 i 0.04 0.13 1912 0.08 0.10
  • 0.02 0.10 i 0.03 0.15
  • 0.02 0.14 1913 0.10 0.07
  • 0.02 0.08
  • 0.02 0.12
  • 0.01 0.10 1914 0.10 0.10
  • 0.03 0.11 0.04 0.13
  • 0.04 0.14 1915 0.04 0.08 0.04 0.13 0.07 0.12 t 0.04 0.13 1916 missing 0.09
  • 0.03 0.09
  • 0.05 0.09
  • 0.08 0.15 1917 0.11 0.10 1 0.02 0.11 t 0.01 0.12
  • 0.06 0.13 1918 0.05 0.09 i 0.02 0.07
  • 0.01 0.13
  • 0.06 0.08 1919 0.05 0.09 t 0.02 0.07 t 0.01 0.13 t 0.06 0.08 1920 0.04 0.07
  • 0.03 0.06
  • 0.03 0.12
  • 0.09 0.07 1921 0.27 0.20 0.06 0.19
  • 0.07 0.36 i 0.15 0.28 1922 0.05 0.09 i 0.02 0.10
  • 0.04 0.10
  • 0.02 0.11 1923 1.57 1.24 i 0.41 1.01
  • 0.27 1.22 i 0.33 1.39 1924 1.01 0.89
  • 0.32 0.69
  • 0.15 0.97
  • 0.16 0.94

-1925 0.16 0.15 t 0.06 0.14 t 0.02 0.19 i 0.04 0.18 1926 0.07 0.11 t 0.05 0.10

  • 0.02 0.16
  • 0.04 0.13 1927 missing 0.10 t 0.04 0.12 i 0.03 0.15 i 0.02 0.10 1930 0.07 0.11
  • 0.04 0.10 i 0.02 0.11 i 0.00 0.13 1932 missing 0.13 i 0.06 0.09 i 0.01 0.12 t 0.02 0.11 1933 0.08 0.10 i 0.04 0.10 t 0.02 0.15
  • 0.01 0.13 1934 0.10 0.13
  • 0.05 0.11
  • 0.02 0.15 t 0.02 0.11 1936 0.30 0.28 i 0.10 0.17 0.04 0.27
  • 0.05 0.30 1938 0.36 0.27 i 0.10 0.19 t 0.03 0.24
  • 0.04 0.24 1939 missing 0.09 0.01 0.09
  • 0.01 0.10 0.00 0.06 1940 0.04 0.09 0.03 0.09
  • 0.02 0.12 i 0.04 0.05 1945 missing 0.11 0.06 0.13
  • 0.05 0.19 i 0.03 miss.

1946 0.17 0.14 i 0.00 0.17 t 0.05 0.18

  • 0.01 miss.

1947 0.16 0.17

  • 0.06 0.10 0.03 0.14
  • 0.04 0.09 A Not a yearly mean; a single TLD exposure period (60-70 days).

B Yearly mean with standard deviation. t.

C.S. SAVANNAB Di-Annunl Micro R Meter Survey Location 1981 1982 1983 1984 1985

Background

Background

Background

Background Bkgrd.

1.3 l 2.0 2.0 l 2.0 1.0 l 0.6 0.6 l 0.6 0.6-(uR/hr)

(uR/hr)

(uR/hr)

(uR/hr)

(uR/hr)

Ecvigation Bridge Deck In pilot house at helm 3.1 2.5 3.5 5.0 1.9 2.0 0.0 1.5 1.0 Bridge wing, portside 2.6 2.0 3.0 4.0 3.0 1.2 0.8 1.5 1.0 Fire Sta. #1 starboard near chart room 2.6 2.0 2.5 2.1 0.0 1.3 0.5 Fan rm.,

portside, emer.

5.2 4.0 1.8 1.5 1.0 1.0 1.5 Gen. room 1.7 3.0 0.5 1.9 1.5 0.8 0.0 1.C 1.0 Boat Deck Chief eng. state rm. port 4.4 3.0 4.0 2.2 2.7 1.2 0.9 1.0 1.0 Cpt. state rm., starbd.

4.9 4.0 3.6 2.7 2.4 1.0 0.5 1.0 1.0 Fire Staf. #2, portside 4.0 2.8 1.7 1.2 0.0 1.0 1.5 Ofer's. lounge, aft 3.4 3.0 0.5 2.1 1.5 0.9 0.4 1.0 1.0 Promenade Deck Aux. reactor hatch &

ducts, forward 1.7 1.2 1.7 1.0 1.8 0.5 0.0 0.5 Main reactor hatch, port.

1.7 3.0 1.0 1.2 1.1 1.2 2.0 0.0 1.0 Fire Sta. #5, starbd.

2.9 2.5 1.9 1.2 1.5 0.2 0.0 1.0 Center of Veranda 3.9 4.0 5.0 3.8 3.8 2.1 0.9 1.0 1.5 Center of main lounge 4.3 5.0 5.1 2.2 2.0 1.1 0.5 1.0 Fire Sta. #7, starbd.

3.1 4.0 3.8 2.8 2.3 1.0 1.0 Fire Sta. #4, portside 2.9 3.1 2.8 1.2 1.0 1.5 1.0 U.S. SAVANNAH.

Di-Annu21 Micro R Meter' Survey Location 1981 1982 1983 1984 1985

Background

Background

Background

Background Bkgrd.

1.3 l 2.0 2.0 l 2.0 1.0 l 0.6 0.6 l 0.6 0.6 (uR/hr)

(uR/hr)

(uR/hr)

(uR/hr)

(uR/hr)

"A" Deck Fire Sta. #14, portside 3.4 4.7 3.2 2.9 2.5 2.0 1.0 1.0 1.0 Center of main lobby 3.4 5.5 5.0 3.0 3.2 1.8 0.5 0.5 1.5 Fire Sta. #16, portside 3.4 3.5 3.5 3.2 2.2 1.7 0.5 1.0 1.0 Fire Sta. #17, starbd.

3.3 3.2 0.8 2.9 2.0 2.2 0.8 1.0 1.0 Fire Sta. 415, starbd.

3.4 5.0 1.7 4.1 3.0 2.0 1.0 1.5 1.0 Outside Dr.'s office 3.4 5.6 5.9 4.3 2.4 0.8 0.8 2.0 1.0 "B" Deck Fire Sta. #20, portside 3.4 3.0 2.5 2.4 2.1 1.1 0.2 0.0 1.0 Fire Sta. #22, portside 3.4 2.9 2.5 1.3 2.1 1.8 0.0 0.0 1.0 Pass. outside stewards mess, portside 3.4 3.2 2.0 3.0 1.8 1.0 0.9 0.0 1.0 Center main dining rm.

3.4 3.1 3.0 3.9 2.5 2.0 0.5 0.0 1.0 Center of conf.

rm.,

aft 3.1 1.9 2.5 2.2 1.8 1.2 1.0 0.0 1.0 Fire Sta. #21, starbd.

R3. 4 3.3 2.5 3.5 1.8 1.0 1.0 1.0 1.5 Pass, outside reactor space water tight door 4.3 3.6 3.0 3.1 1.8 1.5 1.1 1.0 1.0 Inside main galley 4.3 3.1 3.0 3.7 2.1 1.2 0.4 1.0 1.0 "C" Deck Visitors galley, portside 2.5 2.4 3.1 1.0 1.0 2.0 1.0 Visitors galley, mid-ship 3.1 3.0 2.9 2.2 1.0 1.0 2.0 1.0 Visitors galley, starbd.

2.5 3.0 2.2 1.0 1.0 1.0 1.0 Outside forward control door, portside 4.3 7.0 2.9 4.0 1.0 1.0 1.0 Cold chem. lab 6.0 30.0 1.0 2.0 1.0 N.S. SAVANNAH Di-Annual Micro R Meter Survey.

Location 1981 1982 1983 1984 1985

Background

Background

Background

Background Bkgrd.

1.3 l 2.0 2.0 l 2.0 1.0 l 0.6 0.6 l 0.6 0.6 (uR/hr)

(uR/hr)

(uR/hr)

(uR/hr)

(uR/hr)

"D" Deck Reactor control center 2.6 2.1 2.5 1.3 2.2 1.0 1.0 1.0 1.0 Outsd. hot chem lab, ports.

4.3 2.9 5.0 1.7 2.0 1.0 2.0 1.0 Eng. toilet rm., portside 5.0 3.0 1.7 4.0 2.0 2.0 Upper level eng.

rm.,

ports. ---

2.64 2.0 1.2 1.5 1.0 1.0 1.0 1.0 Upper level eng. rm. starbd. ---

2.0 1.3 1.7 1.0 1.0 1.0 1.0 Engine Room - Lower Level Outside port pump rm.

29.0 22.0 2.0 13.0 6.0 11.0 5.0 Outside starbd. pump rm.

32.0 28.0 1.8 13.0 5.0 6.0 7.0 Lower level eng.

rm., port.

6.0 1.0 1.7 1.0 1.0 1.0 1.0 Lower level eng. rm.,starb.

1.0 1.0 1.5 1.0 0.5 1.0 1.0 "14'-0" Flat Outside port stabilizer rm, hatch, closed 32.72 21.0 14.0 10.0 5.0 5.0 5.0 5.0 Outside starbd. stab. rm.

hatch, closed 20.31 4.0 3.0 2.2 1.0 1.0 2.0 1.0 Fire Sta. #34, portside 65.0 150.0 Bottom of steps below port stab. rm. hatch at Fire Sta. door 2.0 17.0 Wall on stairs between 14' flat and "D" deck separating stairs from reactor space 43.0 34.0 U.S. SAVANNAH Ci-Annual Micro R Meter Survey Location 1981 1982 1983 1984 1985

Background

Background

Background

Background Bkgrd.

1.3 l 2.0 2.0 l 2.0 1.0 l 0.6 0.6 { 0.6 0.6 (uR/hr)

(uR/hr)

(uR/hr)

(uR/hr)

(uR/hr)

Cargo Hold Aft bulkhead "B" deck level (next to forward control space) 23.8 13.5 18.0 5.1 2.0 8.0 10.0 Aft bulkhead "C" deck level (next to forward control space) 210.0 205.0 130.0 6.0 14.0 300.0-600.0 --- _

C.S. SAVANNAH Removable Contamination Data Avg. DPM/100cm2 per Year Location 1981 1982E 19835 19845 1985 Beta Beta Beta Beta Beta Alpha lG amma Alpha lG amma Alpha lG amma Alpha lG amma Alpha l Gamma Etvigation Bridge Deck In pilot house at helm 0.5 0.0 0.5 0.3 0.0 1.2 0.6 0.9 0.3 Bridge wing, portside 1.2 2.1 0.8 1.1 0.0 0.0 0.3 0.0 1.0 Fire Sta. #1 near chart rm.

0.1 0.9 0.0 0.0 0.0 0.3 0.3 Fan rm., portside, emer.

0.5 0.6 0.4 0.7 0.3 2.0 0.0 0.3 Gen. room 0.2 1.2 0.0 1.8 0.3 0.6 0.3 0.3 Boat Deck Chief eng. state rm. port 1.2 1.3 0.5 0.7 0.6 1.3 0.1 3.1 Cpt. state rm.,

starbd.

0.5 0.2 0.1 0.0 0.0 0.7 0.3 0.2 0.3 1.0 Fire Staf. #2, portside 0.1 0.9 0.0 0.5 0.1 0.3 0.5 Ofer's. lounge, aft 0.5 1.3 0.0 1.0 0.0 1.7 0.1 0.7 0.3 Promenade Deck Aux. reactor hatch &

ducts, forward 0.3 1.2 0.0 1.0 0.0 0.2 1.8 2.7 Main reactor hatch, port.

0.0 0.0 0.4 0.7 0.9 0.1 0.3 2.7 Fire Sta. 45, starbd.

0.7 1.3 0.0 0.8 0.0 2.1 0.8 0.1 Fire Sta. #4, portside 0.4 0.5 0.0 0.3 0.3 1.6 1.0 Center of Veranda 0.1 1.1 0.0 0.4 0.0 1.4 0.0 0.0 0.8 0.8 Center of main lounge 1.5 1.3 0.5 1.0 0.4 0.7 1.4 0.8 0.3 0.8 Fire Sta. 47, starbd.

0.5 0.0 0.0 0.3 0.1 U.S. SAVANNAH Removable Contamination Data Avg. DPM/100cm2 per Year Location 1981 1982E 1983E 19845 1985 Beta Beta Beta Beta Beta Alpha l Gamma Alpha l Gamma Alpha lG amma Alpha lG amma Alpha l Gamma "A" Deck Fire Sta. #14, portside 0.0 0.4 0.0 2.6 0.0 1.0 0.3 0.8 Center of main lobby 0.1 0.7 0.0 0.8 0.1 0.0 0.8 0.3 Fire Sta. #16, portdide 0.0 1.4 0.8 0.6 0.6 0.6 0.3 0.1 Fire Sta. #17, starbd.

0.0 0.3 0.0 0.0 0.3 2.7 0.5 1.6 Fire Sta. #15, starbd.

0.1 1.6 0.0 2.0 0.0 0.1 0.3 Outside Dr.'s office 2.0 1.9 0.0 0.0 0.2 2.2 0.3 0.7 0.3 "B" Deck Fire Sta. #20, portside 0.2 0.0 0.0 1.0 0.1 0.1 0.3 1.0 0.0 1.0 0.4 0.7 0.0 0.6 1.0 Fire Sta. #22, portside Pass, outside stewards 0.0 1.0 0.0 0.5 0.3 1.5 mess, portside Center main dining rm.

0.3 4.0 0.9 1.0 0.4 0.5 0.1 0.2 0.5 0.3 Center of conf.

rm.,

aft 0.0 0.6 0.7 1.1 0.0 1.6 0.1 0.9 0.5 1.4 Fire Sta. #21, starbd.

0.3 1.9 0.1 1.0 0.0 0.4 0.3 0.5 0.8 1.6 Pass. outside reactor space water tight door 0.2 1.8 0.0 0.9 0.6 1.1 1.2 Inside main galley 0.5 1.5 0.6 1.1 0.0 1.4 0.6 1.1 0.5 "C" Deck Visitors galley, portside 0.0 0.4 0.0 2.5 0.9 0.9 0.8 0.3 Visitors galley, mid-ship 0.6 6.0 3.0 1.3 0.2 1.6 0.3 Visitors galley, starbd.

0.1 1.2 0.5 0.5 0.3 1.1 0.8 Outside forward control door, portside 0.5 3.2 0.0 2.3 0.2 0.6 Cold chem, lab 0.8 2.3 0.6 6.8 0.3 0.1 C.S. SAVANNAH Removable Contamination Data Avg. DPN/100cm2 per Year Location 1981 19825 1983E 19845 1985 Beta Beta Beta Beta Beta Alpha l Gamma Alpha lG amma Alpha l Gamma Alpha lG amma Alpha lG amma "D" Deck Reactor control center 1.2 0.6 0.3 0.5 0.0 1.7 0.0 1.3 0.5 Outsd. hot chem lab, ports.

1.2 0.4 0.0 1.3 0.6 2.4 0.3 2.1 1.0 2.1 Eng. toilet rm., portside 0.1 0.8 0.4 1.1 0.2 0.5 Upper level eng.

rm., ports. ---

0.3 0.2 0.0 1.7 0.0 0.5 1.4 Upper level eng. rm. starbd. ---

0.0 1.4 0.2 1.6 0.0 2.1 0.5 0.3 Engine Room - Lower Level Outside port pump rm.

0.1 5.2 0.0 0.8 0.2 0.3 1.2 Outside starbd. pump rm.

0.0 1.5 0.8 0.5 0.1 0.3 0.5 1.2 Lower level eng. rm., port.

0.1 0.7 0.0 1.3 0.1 1.1 0.8 0.5 Lower level eng. rm.,starb.

0.0 0.0 0.0 2.0 0.1 0.6 0.5 0.3 "14'-0" Flat Outside port stabilizer rm.

hatch, closed 1.8 4.0 0.2 4.7 0.0 2.6 0.0 0.4 0.5 1.2 Outside starbd. stab. rm.

hatch, closed 1.2 0.4 0.2 1.2 0.0 1.0 0.0 0.0 1.0 Fire Sta. #34, portside 0.0 0.0 0.5 2.3

U.C. SAVANNAH Removable Contamination Data Avg. DPN/100cm2 per Year Location 1981 19825 19835 1984E 1985 Beta Beta Beta 3 eta Beta Alpha lGamma Alpha lG amma Alpha lG amma Alpha l Gamma Alpha l G amma_

Cargo Hold Aft bulkhead "B" deck l

level (next to forward control space) 0.6 5.7 2.5 9.3 0.3 1.6 Aft bulkhead "C" deck level (next to forward control space) 0.1 0.4 0.0 0.4 0.1 0.8 C 1982, 1983 and 1984 datas are average of 2 semi-annual reports, d -

N.S. SAVANNAH Environmental Sample Analysis Date Collected Location Radionuclide Activity 3-24-81 surface water'- Cooper H-3 894i30 pci/l River at US Army storage Cs-137 Not Detectable activity TC dock at Co-60 Not Detectable mouth of Goose Creek Ce-144 Not Detectable 7-9-81 Water in horse shoe H-3 4.7x10-5uci/ smear shield tank below Cs-137 Not Detectable containment vessel Co-60 Not Detectable Ce-144 Not Detectable I-131 Not Detectable 7-17-81 Bildge water and H-3 1998.0i45.0pci/l sludge from bildges Cs-137 Not Detectable in engine room space Co-60 34.85i23.87pci/l Ce-144 Not Detectable K-40 239.08i239.81pci/l 9-9-81 Surface water from Cooper H-3 743.0t57.0pci/l River at US Army storage Cs-137 Not Detectable activity TC dock at mouth Co-60 Not Detectable of Goose Creek Ce-144 Not Detectable 9-9-81 Bottom mud from Cooper Cs-137 0.07

  • 0.03pci/l Rover at US Army storage K-40 3.9 i 0.3 pci/l activity TC dock at mouth Nb-95 0.05 0.03pci/l of Goose Creek Co-60 Not Detectable Ce-144 Not Detectable Bi-214 0.03 i 0.1pci/cc Pb-214 0.04 i 0.1pci/cc 11-13-81 Bottom sediment NSS berth Ce-144 0.76*0.20pci/gm Ra-226 2.3 i 0.6pci/gm Be-7 2.3 i 0.3pci/gm Cs-137 0.20i0.06pci/gm Nb-95 0.24t0.07pci/gm 11-13-81 Surface water NSS berth H-3 865
  • 29 pci/l Ra-226 55 i 30 pci/l Bi-214 20 i 5 pci/l Pb-214 20 i 5 pei/l 3-18-82 Bottom sediment NSS berth Cs-137 0.16t0.15pci/gm K-40 35 i 2 pci/gm 1 l

L

N.So SAVANNAH Environmental Sample Analysis Date Collected Location Radionuclide Activity 3-18-82 Surface water NSS berth H-3 459 i 20 pci/1 9-16-82 Surface water NSS berth H-3 1470 i 38 pci/l No detect. gamma 10-5-82 Bottom sediment NSS berth Cs-137 0.4

  • 0.1 pei/gm K-40 14.9*2.7 pci/gm 1-18-83 Surface water NSS berth H-3 1730 i 42 pei/l No Detect. gamma 1-18-83 Surface water NSS berth Cs-137 0.40i0.07 pci/gm 10-17-83 Surface water NSS berth H-3 2050i 45 pci/l No Detect. gamma 10-17-83 Bottom sediment NSS berth No Detect. gamma 3-29-84 Surface water NSS bow H-3 3250 57 pci/l No Detect. gamma 3-29-84 Bottom sediment under Cs-137 0.27i0.10pci/gm bow of NSS Ra-226 2.40i0.7 pci/gm K-40 13.00*1.8pci/gm 3-29-84 Soil from Patriots Point K-40 6.50 i 1.6pci/gm ticket office 9-27-84 Surface water bow NSS H-3 1580i40 pci/l No Detect. gamma 9-27-84 Sediment from under bow Cs-137 0.16i0.10pci/gm of NSS 4.90i3.03pci/gm 9-27-84 Soil from Patriots Point K-40 6.00i0.09pci/gm ticket office 3-20-85 Surface water NSS bow H-3 1090 i 33 pei/l No Detect. gamma Sediment from under bow Cs-137 0.17t0.06pci/gm of NSS Soil from Patriots Point K-40 5.2 i 1.1pci/gm ticket office

~

NS SAVANNAH Sheet No.

Date.

Routine Radiation Monitoring Stations B-os O

-c o,

voto g

WM

~~

m pga a;

[

sa 2.

l.e:.v*.

o u

9q 6,elEtom

c,, ~ a

  1. 3 0,w,

<~ 9,ucy %,,r A-k-

Ob

~

- Amt.,

CAS'MG 7 %ots HCust 6 2 i

w..

,a ftts hM SR

'A SR T

N AVIG ATION BRIDGE DECK E g

I

' ' ~

6estocat swaannatiou assa, m,

s, w

(

)(*%-

)

sa IA

  • ~;,;.y.~ ~,

[a sg

_q M

i W

5 R.

ens

/

o f

oO CmW 6**W EE R 9

I 3

m~

g p

g yy,am,

p SR 5A SR

>g g

l,,

,t

$st- - 1,X "s * * " " ",,,ra an o n,e u es v a.

LouMGE CM 4 N G

'l SR SA

$R L

7

$g CHige CA PTAid Q7 Q

~'

7 H RTLS D,,,,.......

y CFFsCC f

I et-

)(7.s._.

a

- ~,

(

)

5^

BOAT DECK I

e MD v

c--

_w

-s_---_y.,

4 a

a

_m NS SAVANNAH Date:

Sheet No.

Routine Radiation Monitoring Stations B-os c

I L. A J

?

s.

V

.. A...

g 3.-

hlN g

r m,

[

Lov qa n u ro. '

ye am3

. y.....

3.

. :W-i m-r..

. 1. :... s

..,c 1

t I

n

....er I

=

r

_.s

-a

..-...........-/-

P R 0 M EN t.02 DECK

,=.-.J i

6

..,_1 I,; 7.su.4 i

=

s m.u.us

., c_.

... 1...,,i i r-.,

. g -y-: C r I

E il _

I

'i

^

r-

- m u.s

(-

p..:ts

-1..,......

..?

l MA s

' ii..

. %~. ;-g,$..- e

.c :..

1 i,.. r.... g.

gg

.,.... ~.. g,,,,,,g g 4.- E

- -,. ~

....- w -

u.......

b --

... u r

,/2;, 'J r- ;

T ] i il ~ ' '- U C

L2 L J i

E..

L

_..... u' a. y

/

._j I_

e.-

e

...o2

=

i i

i i

I t.~.

I

_5 i

A DECX

.. c u.a. s.

~.....m_

s

....u..

/.

.... i..u..'.... k..J......t..~

. ".S i1

..a [

. [...

j l j

[

8

.....s.,.slr?

g g

y.s..

c.

3.)

Dl N IN G.

,,i it M.AtN

~.

O..

  • D
    . l G A i. i.t:.t.. O w p

O

.,r,,l m.

r r

p _.

noom ?

.~g

...c.

i a

'k b) h =1

[ +.'q,,7, g,q, M/'"

1-!

LJ_f 5

JL YbU d,,h Y

Y U

h ';g' 4 2

a1 i

i 4

i_.

4 I

4 i

I B DECK l

l l

i

1#

,I NS SAVANNAH 1

Sheet No.

Date:

,Houtine Radiation Monitoring Stations s_oy

.i.

..(

_I

6. L.,... <

53 n F1 n

a f1 3-ro : rt=.-.::=

?

s-l LW

(

.....u.

h T-

_s a

q

' n.!

d;]

r....,e c/

4,,....

.. [,

r.

,: :-- C 5 -- i L i 1., "...'.

I d

l.

_ I'c.

e

.c e

p p

i Le pl m:'*:

[j i

L.i y

LJ n

  • y"

'T" l, 3%

o.......,

c OECx

..u.. -.,

u..,

-y

. -sw-je

.[9 4 *F#'

~

.n.

i.......,.

m a

c;l.... c o'*O

~<

~

ll 3 ll']

ll 3

~

..-...,a...

y 1

' ~ ~"'~

ggggg..s

' ENC,tWE Rti

.g.,

g

...u..

r$g,,

,d c p

N

..p;;

g

./

. '82E,L,

a

-a V

4

,c

.s

=

C4 NTis j *,*t' air. ' _j

++j g........

J n '. ""-

s-

"~

i AUX.M ACH'Y FLAT; O DECK s

1 1

\\

l.... ' -

u.....

Po*T

. '.,=,.=.<.,..F.a"T...

e..,

f*..

si...s sing p.,

gg

,,,,/,,

i

-.n fi y y,/

..-..L, 4 < :.

j erom no o **

.c.

..r /, w* ~

/

.g,3;

[.0W f fveL 3

,,..Y l

A V

,. - g%.,,'s I

.bw.. -

.v v.3 0 o

e..&

6,4&s t :44

_Q I,

'W s

.s.

- siaeuse.

W...

t 4'-O' FL A T

)

i

~

l.

NS SAVAXNAH '

Sheet No.

' CONTR0u.ED AREA - F0FMARD CONTROL r

?m pate:

B-10,

MAR 241981 UPPER #U) M L.EVELS

.o

'M r

Y

[-

t C ARGO HOLD N o. 4 FWD l

i,

RaoiATeon Moustonewo. Room l

COLD WATf A

- - + - - - -

v 3

CHEM

[

~T ma Ams A

LAs g/

L G

gg, y

a l

W e

~

e a

m m

e i

2 M

s E

l,...

1,%

t we

/'t' A W A RD CoNTMck UfPEA LfvfL E

4---

TH's S PA

  • L ---->

Curta foewno couraas.

7**d WTo rez.,

RsAcrort comeAttment c Otex CARGQ HOLO N O. 4 Isasn m s'l umegg SI N K l

  • E

&, f*G

$4 t

y*

s.

5o e

8 (NNER 8

O E

<l P6uc.

RADsATicM SAMfLtrdG

[

w s

D GAS ADsoRFTacN

.f

'R O c tW

egunS1,

(

,0 4

s EQV8P. Room M

o O

vatvss g

4 02 4

Q 0-

.vP, r o v v o o o a 10 0 01 M

f LOWER LEvf L - f o lt.W A RO CONTRot "g

k STongo e 4

-7"Hf5 SPACE -

f)

(3.t ACTot. CQnPA RT M CNT s,

l a6

NS SAVANNAH

~

Sheet No.

U****

Routine Radiation Monitoring Stations s.og MAR 2 41981 F

P l

( l r

\\

83 OsARMY i

I ili k

STORAGE AcTiv tT Y t i-i

)

C WA Rt.5 STog S C

.n

\\

i :-

C2.

\\

' i it t

Q

\\

o.

q 5

A b '-

g

.. o s

e x

(\\

l L

\\'

O O

U

[G &

..T.i i-

\\

h

)

\\.

(p l

l

(

o u

s 1

s, i

e+