:on 970123,non-conservative Assumptions Used in TSs Shutdown Margin Curve Identified.Caused by Lack of Procedures for Generation & Documentation of Reactor Operational Info.Engineering Procedure Will Be Revised| ML20135B042 |
| Person / Time |
|---|
| Site: |
Millstone  |
|---|
| Issue date: |
02/21/1997 |
|---|
| From: |
Peschel J NORTHEAST NUCLEAR ENERGY CO. |
|---|
| To: |
|
|---|
| Shared Package |
|---|
| ML20135B028 |
List: |
|---|
| References |
|---|
| LER-97-007, LER-97-7, NUDOCS 9702280057 |
| Download: ML20135B042 (4) |
|
text
.
NRC FORM 366 U.S. NUCLEAR REGULATORY Commission APPROVED BY OMB NO. 3160-0104 pgg EXP1REs 04/30/98 Eo OoN Ne'c'$oN REQ E$T 50 E
Tf D L o
L'a*'?o^"Ana"! "^!'amo 'a,$!=* inWA ^N!:
LICENSEE EVEN T REPORT (LER)
PinU ? 'Mfa%'?u"u'&" ton",'a^%'Ne^s" &
!?PJi%Aaani?AM"T&" n%io:"8 tan"'**'
^
u (See reverse for required number of digits / characters for each block)
FACtWTY NAME 113 DOCKET WUMBER (2)
Pact (3)
Millstone Nuclear Power Station Unit 3 05000423 1 of 4 TITLE 44)
Non-Conservative Assumptions Used in Technical Specifications Shutdown Margin Curve EVENT DATE (5)
LER NUMRER (6)
REPORT DATE (7) oTHER FACILITIES INVOLVED (B)
MONTH DAY YEAR YEAR SEQUENT'AL Revision MONTH DAY YEAR FACluTY NAME DOCKET NUMBER NUMBER 01 23 97 97 007 00 02 21 97 OPERATING THis REPORT is SUBMITTED PURSUANT To THE REQUIREMENTS oF 10 CFR 5: (Check one or more) (11)
DE(m 6
4 20.2201(b) 20.2203(a)(2)(v) 50.73(a)(2)(i)
So.73(a)(2)(viii)
POWER 20.2203(a)(1) 20.2203(a)(3)(i)
So.73(a)(2)(ii)
So.73(a)(2)(x)
LEVEL (10) 000 20.2203(a)(2Hi>
20.2203(a)(3)(ii)
So.73(a)(2)(iii) 73.71 20.2203(a)(2)(ii) 20.2203(a)(4)
So.73(a)(2)(iv) oTHER 20.2203(a)(2)(iv)
So.36(c)(2) 50.73(a)(2)(vii)
LICENSEE CONTACT FOR THIS LER (12)
NAME TELEPHONE NUMBER (include Atee Codel J.M. Peschel, MP3 Nuclear Licensing Manager (860)437-5840 COMPLETE ONE LINE FOR EACH COMPONENT FAILURE DESCRIBED IN THIS REPORT (13)
CAUSE
SYSTEM COMPONENT MANUFACTUNER REPORTABLE
CAUSE
sYUEM COMPONENT MANUFACTURER REPORTABLE TO NPRDS To NPRDs SUPPLEMENTAL REPORT EXPECTED (141 EXPECTED MONTH DAY YEAR SUBM!ssioN f NO YEs (If yes. complete EXPECTED submission DATE).
ABSTRACT (Limat to 1400 spaces. i.e., approximately 15 single-spaced typewritten lines) {161 On January 14,1997, as the result of an engineering review, it was postulated that an incorrect assumption had been made in determining the degree of error in a Cycle 6 Shutdown Margin Curve which had previously been found to be in error. Subsequent Engineering evaluation concluded that the Cycle 6 Shutdown Margin - Mode 3 curve had been non-conservative. On January 23,1997, with the unit in Mode 5, a prompt event report was made to the Nuclear Regulatory Commission of this historical condition pursuant to 10CFR50.72(b)(2)(iii)(A) as an event or condition that alone could have prevented the fulfillment of the safety function of structures or systems that are needed to shutdown the reactor and maintain it in a safe shutdown condition.
The cause of this event has been determined to be the lack of procedures for the generation and documentation of reactor plant operational information.
This condition was significant in that the use of an incorrect curve in determining the RCS boron concentration required to ensure adequate shutdown margin could have prevented the fulfillment of the safety function of the systems needed to maintain the reactor in a safe shutdown condition.. A comparison between the actual RCS boron concentration values measured during periods of Mode 3 operation and the required shutdown margin RCS boron concentrations for Cycle 5 and Cycle 6 verified that, due to intentional over-boration, there had been no violation of the shutdown margin requirements contained within Technical Specification 3.1.1.1.2. Therefore, the safety consequence Cf this event was minimal.
9702280057 970221 PDR ADOCK 05000423 S
PDR
i
- U.S. NUCLEAR RE!ULATCY Commission M 95)
LICENSEE EVENT REPORT (LER)
TEXT CONTINUATION FACILITY NAME (1)
DOCKET NUMBER (2)
LER NUMBER (61 PAGE (3)
YEAR SEQUENTIAL REvislON Millstone Nuclear Power Station Unit 3 05000423 NUMBER NUMBEF) 2 of 4 97 007 00 l
TEXT (11more space is required, use additional copies of NRC Form 366A) 117) 1.
Description of Event
On January 14,1997, as the result of an engineering review, it was postulated that an incorrect assumption had been made in determining the degree of error in a Cycle 6 Shutdown Margin Curve which had previously been found to be incorrect. Subsequent engineering evaluation concluded that the Cycle 6 Shutdown Margin - Mode 3 curve had been n:n-conservative. On January 23,1997, with the unit in Mode 5, a prompt event report was made to the Nuclear Regulatory Commission of this historical condition pursuant to 10CFR50.72(b)(2)(iii)(A) as an event or condition that alone could have prevented the fulfillment of the safety function of structures or systems that are needed to shutdown th3 reactor and maintain it in a safe shutdown condition.
Reactor Engineering produced the Cycle 6 Shutdown Margin - Mode 3 curves in May of 1995. These curves were based upon information contained within the vendor-supplied Nuclear Design Report (NDR). On June 14,1996, it was utscavered that one of the curves (Mode 3, All-Rods-In (minus 1), Reactor Coolant System Temperature equal to 557 degrees Fahrenheit) had been developed improper 1y.
A calculation was pt>rtormed to determine the correct data, which were then compared to the data used to plot the inco rect curve. The original data were found to be non-conservative by up to 4 parts per million (ppm) boron over a core bumup range of 2000-4000 Megawatt Days per Metric Ton Uranium (MWD /MTU). This determination was based upon an assumption that a 100 ppm boron addition to the required shutdown margin RCS boron concentration listed in th2 NDR was 'available margin'. Since the plant was not in Mode 3 during this bumup window, and that the curves were not requimd to be used, the event was determined to be not reportable. A review of other Cycle 6 curves which were developed by Reactor Engineering found no additional errors.
On January 14,1997, it was suggested that the assumption that the 100 ppm boron allowance listed in the NDR was
- could be incorrect. It was subsequently determined that the 100 ppm boron allowance was an analytical margin that could not be used by plant personnel as "available margin'. Without credit for the boron allowance, the bumup window over which the original curve was non-conservative expanded to a range of 0 to
~14500 MWD /MTU. The unit was operated in Mode 3 three times during this bumup window. A review of plant records was conducted to compare actual RCS boron concentration values which were measured during Mode 3 operations to the corrected required shutdown margin RCS boron concentrations. It was verified that, due to ovor-boratiun for extra margin, no violation of the Technical Specification shutdown margin requirements had occurred.
However use of this curve by operations personnelin determining adequate shutdown margin alone could have prevented the reactor from being maintained in a safe shutdown condition.
This condition is therefore being reported pursuant to 10CFR50.73(a)(2)(v)(A), as an event or condition that alone could have prevented the fulfillment of the safety function of structures or systems that are needed to shutdown the re:ctor and maintain it in a safe shutdown condition.
11.
Cause of Event
The cause of this event has been determined to be the lack of procedures for the generation and documentation of re:ctor plant operational information.
l i.
NRC ToRM 366A U.s. NUCLEAR EEGuLAToRY CoMM!ssioN LICENSEE EVENT REPORT (LER)
TEXT CONTINUATION FACILITY NAME (1)
DOCKET NUMBER (2)
LER NUMBER (6)
PAGE (3)
YEAR SEQUENTIAL REVISloN Millstone Nuclear Power Station Unit 3 05000423 NUMBER NUMBER 3 of 4 97 007 00 TEXT Ut more space is required use additional copies of NRC form 366A) l11) lil. Analysis of Event This condition was significant in that the use of an incorrect curve in determining the RCS boron concentration required to ensure adequate shutdown margin could have prevented the fulfillment of the safety function of the systems needed to maintain the reactor in a safe shutdown condition.
A comparison between the actual RCS boron concentration values measured during period of Mode 3 operation and the required shutdown margin RCS boron concentration for Cycle 6 was conducted following determination of the condition being reported. There were no adverse safety consequence in that during this cycle, it was verified that, due to intentional over boration, there had been no violation of the shutdown margin requirements contained within Tcchnical Specification 3.1.1.1.2.
IV. Corrective Action
The following corrective action will be taken:
1.
The Reactor Engineering procedure will be revised to provide for the generation and documentation of reactor plant operational information provided to the operating shift by September 1,1997.
2.
A supplement to LER 96-009-00 will be submitted by March 1,1997 to correct the statement related to additional conservatism.
V.
Additional Information
During the preparation of this report, LER 96-009-00 was reviewed as a potentially similar event. It was determined that the 100 ppm RCS boron allowance listed in the NDR was considered to be "available margin".
Similar Events
LER 96-009-00 Inoperable Shutdown Margin Monitors from Low Count Rate, Due to inadequate Design Control On April 23,1996, with the plant in Mode 5, at 0-percent power, Engineering personnel discovered that both channels of Shutdown Margin Monitors were inoperable due to the instrument count rate being below a minimum count rate for operability. A review of previous outages indicates the condition may have existed three times within the last two years during Mode 5 operation. The condition is prohibited by Technical Specification 3.3.1. Table 3.3-1, item 21, which requires two Shutdown Margin Monitor (SMM) channels to be OPERABLE.
Upon discovery an immediate notification was made pursuant to 10CFR50.72(b)(1)(ii)(B). A subsequent review determined that there was no safety significance associated with the shutdown margin monitors being inoperable. The Reactor Coolant System (RCS) was borated significantiy higher than the boron concentration assumed in the analysis of a dilution event for the shutdown condition. The SMM alarms at a setpoint above the neutron count rate,15 minutes prior to tJaC FORM 366A 44-95)
'U.S. NUCLEAR REIULATORY C MMISSION 1
LICENSEE EVENT REPORT (LER)
TEXT CONTINUATION FACILITY NAME (1)
DOCKET NUMBER (2)
LER NUMBER (6)
PAGE (3)
YEAR SEQUENT 4AL REVISION Millstone Nuclear Power Station Unit 3 05000423 NUMBER NUMBER 4Of4
)
97 007 00 TEXT lif more space is required, use additional copies of NRC Form 3SSA) (17) criticality, to provide time for operator action to mitigate an unintended dilution. A review of this event and the historical events indicated that the actual, higher than required, RCS boron 1
concentrations provided reasonable assurance of meeting the required 15-minute alarm time to J
criticality for a postulated dilution event.
As immediate action the plant complied with the app'icable Technical Specification Action Statement. The action taken to prevent recurrence was to reduce the SMM setpoint. During a corrective action review of the vendor's boron dilution analysis, a potential non-conservative assumption on subcritical multiplication was identified, and an immediate notification was made on May 13,1996, pursuant to 10CFR50.72(b)(1)(ll)(B). A subsequent review determined that the analysis was acceptable, and the plant was not in a condition that was outside the design basis.
Manufacturer Data None 1
4 4
8 l
1 a
k e
a 1
4
|
|---|
|
|
| | | Reporting criterion |
|---|
| 05000245/LER-1997-001-02, :on 970110,liquid Radwaste Effluent Radiation Monitor Declared Inoperable Due to Leaking Automatic Isolation Valves.Valves Repaired |
- on 970110,liquid Radwaste Effluent Radiation Monitor Declared Inoperable Due to Leaking Automatic Isolation Valves.Valves Repaired
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition | | 05000245/LER-1997-001, Forwards LER 97-001-00,documenting Event That Occurred at Millstone Nuclear Power Station,Unit 1 on 970110.Util Commitments Made within Ltr,Listed | Forwards LER 97-001-00,documenting Event That Occurred at Millstone Nuclear Power Station,Unit 1 on 970110.Util Commitments Made within Ltr,Listed | 10 CFR 50.73(a)(2)(i) | | 05000423/LER-1997-001, Submits Commitments Re LER 97-001-00,documenting Condition Determined at Plant on 970104 | Submits Commitments Re LER 97-001-00,documenting Condition Determined at Plant on 970104 | 10 CFR 50.73(a)(2)(i) | | 05000423/LER-1997-001-01, :on 970104,discovered Lack of Verbatim Compliance W/Ts SRs for 125 Volt Batteries & Battery Chargers.Caused by Misconception That Performing Surveillances Was Acceptable.Revised Procedures |
- on 970104,discovered Lack of Verbatim Compliance W/Ts SRs for 125 Volt Batteries & Battery Chargers.Caused by Misconception That Performing Surveillances Was Acceptable.Revised Procedures
| 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(iii) | | 05000423/LER-1997-002, :on 970108,torquing of Battery Connections Not Performed as Part of Connection Tightness Checks Occurred. Caused by Lack of Effective Verification & Validation of Maint Procedure.Procedure Revised |
- on 970108,torquing of Battery Connections Not Performed as Part of Connection Tightness Checks Occurred. Caused by Lack of Effective Verification & Validation of Maint Procedure.Procedure Revised
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) | | 05000245/LER-1997-002, Forwards LER 97-002-00 Which Documents an Event That Occurred at Mnps,Unit 1 on 970114,per 10CFR50.73(a)(2)(iv). Commitments Made,Listed | Forwards LER 97-002-00 Which Documents an Event That Occurred at Mnps,Unit 1 on 970114,per 10CFR50.73(a)(2)(iv). Commitments Made,Listed | 10 CFR 50.73(a)(2)(iv), System Actuation | | 05000245/LER-1997-002-02, :on 970114,inadvertent Shutdown Cooling Isolation Occurred During Sys Removal from Svc for Maint. Caused by Inadequacy in Preparation of Clearance Required to Perform Maint.Individuals Involved Have Been Counseled |
- on 970114,inadvertent Shutdown Cooling Isolation Occurred During Sys Removal from Svc for Maint. Caused by Inadequacy in Preparation of Clearance Required to Perform Maint.Individuals Involved Have Been Counseled
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) | | 05000336/LER-1997-002, Forwards LER 97-002-00 Which Documents an Event That Occurred on 970108,per 10CFR50.73(a)(2)(ii).Commitments Made within Ltr,Listed | Forwards LER 97-002-00 Which Documents an Event That Occurred on 970108,per 10CFR50.73(a)(2)(ii).Commitments Made within Ltr,Listed | 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition | | 05000336/LER-1997-002-01, :on 970108,damper 2-HV-210 Could Not Be Manually Operated within Ten Minutes as Required in Accident Analysis.Caused by Inadequate Evaluation of Mechanical Binding.Damper Was Placed in Fail Open Position |
- on 970108,damper 2-HV-210 Could Not Be Manually Operated within Ten Minutes as Required in Accident Analysis.Caused by Inadequate Evaluation of Mechanical Binding.Damper Was Placed in Fail Open Position
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000423/LER-1997-003, Forwards LER 97-003-00 Which Documents Condition That Was Determined at Mnps,Unit 3 on 970113,per 10CFR50.73(a)(2)(ii) (B).List of Commitments,Encl | Forwards LER 97-003-00 Which Documents Condition That Was Determined at Mnps,Unit 3 on 970113,per 10CFR50.73(a)(2)(ii) (B).List of Commitments,Encl | 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition | | 05000423/LER-1997-003-01, :on 970113,potential for Recirculation Spray Sys Piping Failure Occurred Due to RSS Pump Stopping & Restarting During Accident Conditions.Performed Evaluation of RSS Water Column Separation Issue |
- on 970113,potential for Recirculation Spray Sys Piping Failure Occurred Due to RSS Pump Stopping & Restarting During Accident Conditions.Performed Evaluation of RSS Water Column Separation Issue
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function | | 05000336/LER-1997-003-01, Corrected Page One to LER 97-003-01:on 961216,discovered Discrepancy in Plant Procedure Utilized to Perform Periodic Insp of Fire Protection Sys Smoke Detectors.Caused by Failure to Properly Incorporate Ts.Ts Partially Revis | Corrected Page One to LER 97-003-01:on 961216,discovered Discrepancy in Plant Procedure Utilized to Perform Periodic Insp of Fire Protection Sys Smoke Detectors.Caused by Failure to Properly Incorporate Ts.Ts Partially Revised | 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) | | 05000245/LER-1997-003, Forwards LER 97-003-00 Which Documents an Event That Occurred at Mnps,Unit 1 on 970306,per 10CFR50.73(a)(2)(i). Commitments Made within Ltr,Listed | Forwards LER 97-003-00 Which Documents an Event That Occurred at Mnps,Unit 1 on 970306,per 10CFR50.73(a)(2)(i). Commitments Made within Ltr,Listed | 10 CFR 50.73(a)(2)(i) | | 05000245/LER-1997-003-02, :on 970306,svc Water Effluent Was Not Monitored Per Requirements of Ts.Caused by Inadequate Design Change Package.Procedures to Ensure That SW Effluent from Reactor Bldg Operated within Design Basis Revised |
- on 970306,svc Water Effluent Was Not Monitored Per Requirements of Ts.Caused by Inadequate Design Change Package.Procedures to Ensure That SW Effluent from Reactor Bldg Operated within Design Basis Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) | | 05000336/LER-1997-004-01, :on 970123,violation of TS 3.1.2.3 Requirement for Number of High Pressure Safety Injection Pumps Capable of Injecting Into RCS Occurred.Caused by Personnel Error. HPSI Pumps Have Been Revised |
- on 970123,violation of TS 3.1.2.3 Requirement for Number of High Pressure Safety Injection Pumps Capable of Injecting Into RCS Occurred.Caused by Personnel Error. HPSI Pumps Have Been Revised
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(viii) | | 05000245/LER-1997-004-01, Forwards LER 97-004-01,documenting Closure of Commitment B16213-1.Includes Commitments Made within This Ltr | Forwards LER 97-004-01,documenting Closure of Commitment B16213-1.Includes Commitments Made within This Ltr | 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition | | 05000245/LER-1997-004-02, :on 970127,RBCCW Containment Isolation Sys Single Failure Vulnerability Occurred.Caused by Failure to Adequately Establish Design Basis.No Immediate CA Are Required |
- on 970127,RBCCW Containment Isolation Sys Single Failure Vulnerability Occurred.Caused by Failure to Adequately Establish Design Basis.No Immediate CA Are Required
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) | | 05000245/LER-1997-004, :on 970127,RBCCW Containment Isolation Valve May Not Close within Specified Time.Caused by Failure to Adequately Establish Design Basis.Plant Is in Cold Shutdown W/Reactor Defueled |
- on 970127,RBCCW Containment Isolation Valve May Not Close within Specified Time.Caused by Failure to Adequately Establish Design Basis.Plant Is in Cold Shutdown W/Reactor Defueled
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(ii)(A), Seriously Degraded 10 CFR 50.73(a)(2)(iii) | | 05000423/LER-1997-004, :on 970114,lack of Verbatim Compliance with TS Surveillance Requirements for Molded Case Circuit Breakers Occurred.Caused by Addl Lack of Verbatim Compliance. Corrected 18 Month Surveillances Will Be Performed |
- on 970114,lack of Verbatim Compliance with TS Surveillance Requirements for Molded Case Circuit Breakers Occurred.Caused by Addl Lack of Verbatim Compliance. Corrected 18 Month Surveillances Will Be Performed
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(iii) | | 05000245/LER-1997-005-01, Forwards LER 97-005-01,documenting Closure of Commitment B16236-2 & B16236-3,including Commitments Made within Ltr | Forwards LER 97-005-01,documenting Closure of Commitment B16236-2 & B16236-3,including Commitments Made within Ltr | 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition | | 05000245/LER-1997-005, :on 970115,discovered That Radwaste Storage Bldg Vent Exhaust Fan HVE-14 Discharges Directly to Atmosphere.Caused by Inadequate Design Review.Operation of Exhaust Fan HVE-14 Was Prevented Immediately |
- on 970115,discovered That Radwaste Storage Bldg Vent Exhaust Fan HVE-14 Discharges Directly to Atmosphere.Caused by Inadequate Design Review.Operation of Exhaust Fan HVE-14 Was Prevented Immediately
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2)(viii) | | 05000336/LER-1997-005-02, :on 970204,inservice Test Instrumentation Did Not Meet Ansi/Asme Chapter XI Requirements.Caused by Inadequate Administrative Structure for IST Program. Procedure to Administer IST Program Was Implemented |
- on 970204,inservice Test Instrumentation Did Not Meet Ansi/Asme Chapter XI Requirements.Caused by Inadequate Administrative Structure for IST Program. Procedure to Administer IST Program Was Implemented
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | | 05000336/LER-1997-005, Forwards LER 97-005-00 Which Documents Event That Occurred at Mnps,Unit 2 on 970204.Commitments Made,Listed | Forwards LER 97-005-00 Which Documents Event That Occurred at Mnps,Unit 2 on 970204.Commitments Made,Listed | 10 CFR 50.73(a)(2)(i) | | 05000423/LER-1997-005, Corrects Numbering Inconsistency in Commitments Addressing LER 97-005-00 | Corrects Numbering Inconsistency in Commitments Addressing LER 97-005-00 | | | 05000245/LER-1997-006-01, :on 970131,failure to Exert Best Efforts to Restore Radwaste Effluent Line Radiation Monitor to Operable Status Occurred.Caused by Failure to Provide Clear Management Expectations.Management Will Be Provided |
- on 970131,failure to Exert Best Efforts to Restore Radwaste Effluent Line Radiation Monitor to Operable Status Occurred.Caused by Failure to Provide Clear Management Expectations.Management Will Be Provided
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(iii) 10 CFR 50.73(a)(2) | | 05000423/LER-1997-006, :on 970117,RHR Suction Isolation Valves Open But Not Under Administrative Control as Required in Mode 4 by TS SR 4.6.1.1.a.Caused by Failure to Identify Conflict Between Requirements.Rhr Required Position Determined |
- on 970117,RHR Suction Isolation Valves Open But Not Under Administrative Control as Required in Mode 4 by TS SR 4.6.1.1.a.Caused by Failure to Identify Conflict Between Requirements.Rhr Required Position Determined
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000423/LER-1997-006-01, Forwards LER 97-006-01 Per 10CFR50.73(a)(2)(i).Util Commitments in Response to 970117 Event Contained within Attachment 1 | Forwards LER 97-006-01 Per 10CFR50.73(a)(2)(i).Util Commitments in Response to 970117 Event Contained within Attachment 1 | 10 CFR 50.73(a)(2)(i) | | 05000336/LER-1997-006-02, :on 970211,main Steam Line Break Inside Containment Event Could Result in Exceeding Design Pressure of Primary Containment During Certain Scenarios.Caused by Inadequate Evaluation.Ca Will Be Implemented |
- on 970211,main Steam Line Break Inside Containment Event Could Result in Exceeding Design Pressure of Primary Containment During Certain Scenarios.Caused by Inadequate Evaluation.Ca Will Be Implemented
| 10 CFR 50.73(a)(2)(ii)(B), Unanalyzed Condition 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) | | 05000245/LER-1997-006, Forwards LER 97-006-00,documenting Condition That Was Discovered at Millstone Nuclear Station,Unit 1 on 970131, Per 10CFR50.73(a)(2)(i).Util Commitments Made within Ltr, Listed | Forwards LER 97-006-00,documenting Condition That Was Discovered at Millstone Nuclear Station,Unit 1 on 970131, Per 10CFR50.73(a)(2)(i).Util Commitments Made within Ltr, Listed | 10 CFR 50.73(a)(2)(i) | | 05000336/LER-1997-006, Forwards LER 97-006-00 Which Documents an Event That Occurred on 970211.Commitments Made within Ltr,Listed | Forwards LER 97-006-00 Which Documents an Event That Occurred on 970211.Commitments Made within Ltr,Listed | 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition | | 05000245/LER-1997-007, Forwards LER 97-007-00,documenting Condition That Was Discovered at Millstone Nuclear Power Station,Unit 1 on 970131,per 10CFR50.73(a)(2)(i) & 10CFR50.73(a)(2)(ii). Util Commitments Made within Ltr,Listed | Forwards LER 97-007-00,documenting Condition That Was Discovered at Millstone Nuclear Power Station,Unit 1 on 970131,per 10CFR50.73(a)(2)(i) & 10CFR50.73(a)(2)(ii). Util Commitments Made within Ltr,Listed | 10 CFR 50.73(a)(2)(i) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition | | 05000336/LER-1997-007-02, :on 970308,inadequate Surveillance Procedure Used for Verifying Operability of RCS Vents.Caused by Failure to Incorporate TS SRs Into Plant Surveillance Procedures.Revised Surveillance Procedure |
- on 970308,inadequate Surveillance Procedure Used for Verifying Operability of RCS Vents.Caused by Failure to Incorporate TS SRs Into Plant Surveillance Procedures.Revised Surveillance Procedure
| 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2) | | 05000336/LER-1997-007, Provides List of Commitments for LER 97-007-00 Re Event That Occurred on 970308 | Provides List of Commitments for LER 97-007-00 Re Event That Occurred on 970308 | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | | 05000423/LER-1997-007, :on 970123,non-conservative Assumptions Used in TSs Shutdown Margin Curve Identified.Caused by Lack of Procedures for Generation & Documentation of Reactor Operational Info.Engineering Procedure Will Be Revised |
- on 970123,non-conservative Assumptions Used in TSs Shutdown Margin Curve Identified.Caused by Lack of Procedures for Generation & Documentation of Reactor Operational Info.Engineering Procedure Will Be Revised
| 10 CFR 50.73(a)(2)(v)(A), Loss of Safety Function - Shutdown the Reactor 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(i) | | 05000245/LER-1997-008, Forwards LER 97-008-00,documenting Condition That Was Discovered at Millstone Nuclear Power Station,Unit 1 on 970203,per 10CFR50.73(a)(2)(ii).Util Commitments Made within Ltr,Listed | Forwards LER 97-008-00,documenting Condition That Was Discovered at Millstone Nuclear Power Station,Unit 1 on 970203,per 10CFR50.73(a)(2)(ii).Util Commitments Made within Ltr,Listed | 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition | | 05000423/LER-1997-008, :on 970124,TS 3.0.3 Action Statement for MSIV Closure Was Entered Due to TS Being Inconsistent W/Msiv Safety Function & Design.Submitted Proposed License Amend Request Ptscr 3-13-95 |
- on 970124,TS 3.0.3 Action Statement for MSIV Closure Was Entered Due to TS Being Inconsistent W/Msiv Safety Function & Design.Submitted Proposed License Amend Request Ptscr 3-13-95
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) | | 05000336/LER-1997-008, Forwards LER 97-008-00,documenting Event Occurred at Unit 2 on 970310.Commitments Made within Ltr Listed as Submitted | Forwards LER 97-008-00,documenting Event Occurred at Unit 2 on 970310.Commitments Made within Ltr Listed as Submitted | 10 CFR 50.73(a)(2)(i) | | 05000336/LER-1997-008-02, :on 970310,repts Review Facility Compliance W/ GL 96-01 for Reactor Protective Sys Received.Caused by Inadequate Program to Ensure Surveillance Procedures Fully Implement TS Requirements.Procedures Revised |
- on 970310,repts Review Facility Compliance W/ GL 96-01 for Reactor Protective Sys Received.Caused by Inadequate Program to Ensure Surveillance Procedures Fully Implement TS Requirements.Procedures Revised
| 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(viii) | | 05000245/LER-1997-008-01, :on 970203,discovered Starting Air Sys Operating Outside Design Basis.Caused by Failure to Properly Identify & Verify Design Basis.Design Basis Established & Documented in FSAR |
- on 970203,discovered Starting Air Sys Operating Outside Design Basis.Caused by Failure to Properly Identify & Verify Design Basis.Design Basis Established & Documented in FSAR
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) 10 CFR 50.73(a)(2) | | 05000336/LER-1997-009, Forwards LER 97-009-00,which Documents an Event That Occurred on 970325.Commitments Made within Ltr,Submitted | Forwards LER 97-009-00,which Documents an Event That Occurred on 970325.Commitments Made within Ltr,Submitted | 10 CFR 50.73(a)(2)(i) | | 05000336/LER-1997-009-02, :on 970325,insufficient ESFAS Surveillance Testing,Per GL 96-01 Review Occurred.Caused by Inadequate Program to Ensure Surveillance Procedures Fully Implement TS Requirements.Procedures Will Be Revised |
- on 970325,insufficient ESFAS Surveillance Testing,Per GL 96-01 Review Occurred.Caused by Inadequate Program to Ensure Surveillance Procedures Fully Implement TS Requirements.Procedures Will Be Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000245/LER-1997-009-01, :on 970212,reactor low-low Level ECCS & Primary Containment Initiation Setpoints Were Not Conservative. Caused by Deficient Setpoint Methodology.Calculations Will Be Revised & TS Change Initiated |
- on 970212,reactor low-low Level ECCS & Primary Containment Initiation Setpoints Were Not Conservative. Caused by Deficient Setpoint Methodology.Calculations Will Be Revised & TS Change Initiated
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iii) | | 05000245/LER-1997-009, Forwards LER 97-009-00,documenting Condition That Was Discovered at Millstone Nuclear Power Station,Unit 1 on 970212.Util Commitments Made within Ltr,Listed | Forwards LER 97-009-00,documenting Condition That Was Discovered at Millstone Nuclear Power Station,Unit 1 on 970212.Util Commitments Made within Ltr,Listed | 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition | | 05000336/LER-1997-009-01, :on 970325,insufficient ESFAS Surveillance Testing,Per GL 96-01,noted.Caused by Inadequate Program to Ensure Sps Fully Implement TS Requirements.Operational Surveillances Will Be Revised |
- on 970325,insufficient ESFAS Surveillance Testing,Per GL 96-01,noted.Caused by Inadequate Program to Ensure Sps Fully Implement TS Requirements.Operational Surveillances Will Be Revised
| 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000423/LER-1997-009-01, Forwards LER 97-009-01,documenting Condition Originally Determined Reportable at Unit 3 on 970123.Util Commitments in Response to Event Contained within Attachment 1 to Ltr | Forwards LER 97-009-01,documenting Condition Originally Determined Reportable at Unit 3 on 970123.Util Commitments in Response to Event Contained within Attachment 1 to Ltr | 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2) | | 05000336/LER-1997-010, Forwards LER 97-010-00,documenting Event Occurred at Unit 2 on 970112.Commitments Made within Ltr Listed | Forwards LER 97-010-00,documenting Event Occurred at Unit 2 on 970112.Commitments Made within Ltr Listed | 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications | | 05000423/LER-1997-010, :on 970129,electrical Calculation Discrepancies Identified in Min Voltage Analysis for Class 1E Electrical Sys.Caused by Lack of Configuration Mgt for Comprehensive Calculation Program.Program Being Revised |
- on 970129,electrical Calculation Discrepancies Identified in Min Voltage Analysis for Class 1E Electrical Sys.Caused by Lack of Configuration Mgt for Comprehensive Calculation Program.Program Being Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) | | 05000245/LER-1997-010-01, :on 970214,determined LLRT Pressure Being Used May Be Less than Accident Pressure.Caused by Weakness in Mgt Commitment to App J Program.Llrts Modified |
- on 970214,determined LLRT Pressure Being Used May Be Less than Accident Pressure.Caused by Weakness in Mgt Commitment to App J Program.Llrts Modified
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition | | 05000245/LER-1997-010, Forwards LER 97-010-00,documenting Event Occurred at Unit 1 on 970214.Commitments Made within Ltr Submitted as Listed | Forwards LER 97-010-00,documenting Event Occurred at Unit 1 on 970214.Commitments Made within Ltr Submitted as Listed | 10 CFR 50.73(a)(2)(i) | | 05000336/LER-1997-010-02, :on 970112,heavy Dummy Fuel Assembly & Handling Tool Weight Exceeded TS Limit Occurred.Caused by Weight of Handling Tool Never Considered to Be Part of Load.Temporary Measure & Appropriate Procedures Revised |
- on 970112,heavy Dummy Fuel Assembly & Handling Tool Weight Exceeded TS Limit Occurred.Caused by Weight of Handling Tool Never Considered to Be Part of Load.Temporary Measure & Appropriate Procedures Revised
| 10 CFR 50.73(a)(2)(v), Loss of Safety Function 10 CFR 50.73(a)(2)(vii), Common Cause Inoperability 10 CFR 50.73(a)(2)(iv), System Actuation 10 CFR 50.73(a)(2)(i)(B), Prohibited by Technical Specifications 10 CFR 50.73(a)(2)(i) 10 CFR 50.73(a)(2)(x) 10 CFR 50.73(a)(2)(iii) 10 CFR 50.72(b)(3)(ii), Degraded or Unanalyzed Condition 10 CFR 50.73(a)(2)(viii) |
|