Informs of Three Addl Improvements in Fire Fighting Re Reasonable Assurance of Hose Stream Access Into Dense Concentration of Cable Trays in Northwest Corner of Cable Spreading Room.W/One Oversize Drawing
ML20133G918
Person / Time
Site: Beaver Valley
Issue date: 10/08/1985
From: Carey J
DUQUESNE LIGHT CO.
To: Thompson H
Office of Nuclear Reactor Regulation
Shared Package
ML20133G920 List:
References
2NRC-5-137, TAC-62882, NUDOCS 8510160185
Download: ML20133G918 (4)


Text

.

,glV 4

31 %

<2 1 14 Nuclear Construction Dmsson Telecopy Nts uYgb' *is2Os October 8, 1985 United States Nuclear Regulatory Commission Washington, DC 20555 ATTENTION:

Mr. Hugh L. Thompson, Jr., Director Division of Licensing Office of Nuclear Reactor Regulation

SUBJECT:

Beaver Valley Power Station - Unit No. 2 Docket No. 50-412 Decision on Cable Spreading Rcom Backfit Appeal

REFERENCE:

NRC Letter to DLC, dated July 11, 1985 Gentlemen:

Duquesne Light Company (DLC) has reviewed your decision to accept the Beaver Valley Power Station Unit 2 (BVPS-2) autom,atic total flooding carbon dioxide fire suppression systen as the primary systen with permanent hose stations as backup in the cable spreading room.

in the above referenced letter, you found that for the BVPS-2 cable spreading roon, the CO2 systen with hose stations and fire brigade as the backup is adequate with the excep-tion of the northwest corner:

"The northwest corner of the cable spreading roon has a very dense concentration of cable trays and direct access to this area by the fire brigade is limited."

In conclusion, you found that there was not "... reasonable assurance of hose stream access into the dense concentration of cable trays in the northwest corner of the cable spreading roon." You then considered this to be a devia-tion from the SRP and requested justification be submitted to the staff.

DLC still contends that water can be applied to all areas of this northwest corner by utilizing nonnal fire fighting tools.

However, rather than a fixed fog nozzle normally reconmended for cable fires, an adjustable nozzle in the straight strean position may be required to get water to all areas of the northwest corner.

Further review has been conducted in this area and three additional improvements are being implenented.

These improvements include the renoval of the control roon bench boards access platforms, the relocation of conduit, and the purchase of application " navy" nozzles. The renoval of the access platfonns and relocation of conduit improves the access into this northwest corner by an additional six feet (see attached Drawing 12241-RE-34A, Rev.

10).

The applicators will act as an extension to the hoze nozzle and allow the fire brigade to reach hard-to-get-to areas.

Two different types of hf aN' '

8510160185 051000 l

8 DR ADOCK 050 2

i $

7 i

"D

  • g)

i 1

United States Nuclear Regulatory Connission j

i Mr. Hugh L. Thompson j

Decision on Cable Spreading Roan Backfit Appeal Page 2 1

I

^

1 applicators are being considered:

a six-foot straight applicator and a i

ten-foot 90* applicator (the attached brochure shows a 90* applicator and j

applicator nozzles),

i i

i These three additional improvements to the fire fighting capability in the northwest corner of the cable spreading roon, along with the experi-i ence and capabilities of DLC fire brigade and local fire departments, provide i

DLC with the necessary confidence that any fires in the cable spreading roon including the northwest corner can be reached with a hose strean.

DLC l

concludes that the implenentation of these three improvenents provides the j

additional assurance that the staff has requested.

1 BVPS-2 has an alternate shutdown panel, which, electrically, is totally independent of the cable spreading roon and cable tunnel area which can safely shutdown the plant.

Therefore, should a total burnout of these areas occur, the safety of the public will not be affected.

l The second request of your July 15, 1985, letter related to the i

iiaplementation of the DLC Human Factors reconmendations.

OLC is presently considering these reconmendations and will address their merits in a future i

letter to the staff.

I j

DUQUESNE LIG T COMPANY l

l gik By Pe e

i 1

ETE/wjs l

Attachment cc:

Mr. B. K. Singh, Project Manager (w/a)

{

Mr. G. Walton, NRC Resident Inspector (w/a)

SUBSCRIBED AND SW0y TJ)I/A __,1985.BJFO 7//DAYOF A/2&

h8 x nd S

I Notary Public i

l ANITA EtAINE REITER, NOTARY PUBLIC ROBINSON TOWNSHIP, ALLEGHENY COUNTY MY COMMISSION EXPlRES OCTOBER 20,1986 i

l 1u.

1 United States Nuclear Regulatory Connission Mr. Hugh L. Thompson Decision on Cable Spreading Room Backfit Appeal Page 3 i

C0f140NWEALTH OF PENNSYLVANIA )

l

)

SS:

1

)

COUNTY OF

)

i

//((, before me, a On this M

day of I

Notary Public in and for said Commonwealth and County, personally appeared

]

J. J. Carey, who being duly sworn, deposed and said that (1) he is Vice President of Duquesne Light, (2) he is duly authorized to execute and file j

the foregoing Submittal on behalf of said Company, and (3) the stateinents set forth in the Submittal are true and correct to the best of his knowledge.

I i

Notary Pu)lic ANITA ELAINE REITER, NOTARY PUBLIC ROBINSON TO?!NSHIP, ALLEGiiENY COUNTY MY COMMISS!0N EXPIRES CCTOGER 20,1986 j

l i

i i

i l

l l

1 t

me t

_ _S m -m-m _ m.,

~

j ee g

{.

g i f

gf

", 4 416,.h J Ogg i

Rockwood Stock Nos.

ROCKWOOD Water Fog Nozzles

$848. Aluminum ROCg OOD SG47. Bronze Ball Valves All-Purpose Nozzles are easy to handle in action, Or Chrome Detachable and put out fires faster and more efficiently in x

Jet Tips ordinary combustibles and in flammable liquids.

4 Three positions with shutoff, fog or straight NAVY APPROYAL for SG47 Neule stream. Floating ball valve with smooth bore, g

,g, g,3

/

g straight stream guarantees positive seating and Nonles Carry Followmg Approval:

" finger tip" operation. Available in 3 sues alone,

(

j or with low velocity extension applicators. All 1%* Federal Stock No. GF4210 392-2943 2%* Federal Stock No. GF4210 392 2944 nozzles and applicators tested and listed by Underwriters' Laboratories and approved by FM.

NR45. 1%"

Low Velocity Heads for Rockwood Fog Nozzle Extension Applicators N

^

15if

?

With or Withsut Applicators 1

Rockrood Fog Nozzles discharge high velocity fog thru detachable Coast Guard Head L.12A.

L 11A.

L 10A.

tips with impinging jet streams. Lightweight extension applicators discharge low velocity fog in umbrella pattern. Bayonet type k

Stock'No. Nonle AssemblyG Brass t Chron e Aluminuni:

3

optional on request; for applicator clips see Page 55. Nozzles 1848.1"lignis Only 322 $1NM i

priced alone, or with applicators; for separate applicator price p

1m41. Mth F 900 A=al

' 1RN 1RN I

deduct nozzle only. Separate tips or heads are available P0A.

127.85$185.00l IIR45 1%" llante Guly 97.88

\\ROCKEOOD FOG NOZZLE KARGE DATA ISE Mth F 60' Appt 137.03 - 187.83. 1 4 00 1

-IIR47. Mth r 90' Appl

' 143.00 173.00.151.00 j ingh v. ma -

str. steen \\

tow vei. For

' IM48. 2 With IF 900 Appl '

' 1R05 188.88 158.N ]

Stock No. She GPM Range GPU Range pGPM Range NRSS. 2 " Nonle Only 1RN 1 ROB 1200!

N4!.' Ib

' N 2! t' IN $ I N $ f['

NR51. With 1F 90% Appi.,

188.08 283.08 197.00 :

l NR50. 2%-

115 30 ft 270 100 ft$ _ 115 22 ft.

,yithJ,2{ 90o Appl INE 210m 204.00 !

i j

~

NCERI.

U.S. COAST GUARD 3

{/"F"E APPROVED FOG NOZZLES NR26.1%"

COAST GUARD APPROVAL Nes.

Foam Nozzle I

ROCKWOOD With Pick-Up 1%* No.162.027/2/1 FOAM NOZZLES l

2%* No.162.027/ 3/1 Tube g

Features new y 1% Navy Nonle (NR29) g 4

style rotating With Pick-Up Tube is:

I.

& cutting fog Class C, Type i tips for dirty Federal Stock Numbers marine water.

4214287 8583 (NS) 1 4210 255 6225 (NPSH) l Designed for and approved by the U.S. Coast Guard for marine NR25 to.28. Foam Nozzles are straight, rigid playpipe type.

applications, or for use with water containing foreign matter.

Available with 6 ft. detachable pick up tube and selector valve Applicators have special"CG" low velocity fog heads shown above.

for direct foam induction at nozzle, or plain model for " pre.

mixed" foam solution. Use either 3% or 6% foam by selector U.S. COAST GUARD FOG N0ZZLES valve. U/L approved. NR29. Navy Type has reinforced flexible Stock No.

Nozzle Assembly Brass Only tube with chain for bending tube around corners; brass trim only.

NCGR1.

1%" Nozzle Only

. $102.00 Stock No.

Description Brass Chrome NCGR1A. With 4 ft. 603 Applicator.

141.00 NR25. 1%" Foam Nozzle Plain.

..$85.00

$97.00 NCGR18. With 10 ft. 90o Applicator.

155.00 NR26. 1%" With Pick.Up Tube.

.116.00 121.00 NCGR2.

2%" Nozzle Only 123.00 NR27, 2%" Foam Nozzle Plain.

.176.00 182.00 NCGR2A. With 12 ft. 90o Applicator.

195.00 p

NR28. 2%" With Pick.Up Tube.

. 226.00 231.00 Srparata Applicator Prices..

Deduct Price of Nozzle Only NR29. 1%" Navy Type With Pick

.168.00

_ _ _ _ _ _ _ _ _ Up.__

OVERSIZE DOCUMENT PAGE PULLED SEE APERTURE CARDS NUMBER OF PAGES:

l ACCESSION NUMBER (S):

95 / 0/G O/ 90s l

APERTURE CARD /HARD COPY AVAILABLE FROM RECORD SERVICES BRANCH,TIDC i

FTS 492-8989

-